Home

Thickness Gauge

image

Contents

1. 9 99 mm 0 04 mm 10 99 99 mm 0 1 0 04 mm 100 250 mm 0 03 Power Supply Two 1 5 V AAA dry cells Size 61w x 108h x 28d mm 2 4w x4 3h x 1 1d in Weigh 150g 5 3 oz with batteries Operating Temperature 10 C to 50 C 14 F to 122 F Storage Temperature 20 C to 60 C 4 F to 140 F Probe Types and Measuring Range Standard Probe PT 08 5 0 MHz measuring range 1 0 200 mm 04 to 7 9 inches Battery Replacement Disposal Battery Replacement The Thickness Gauge uses two 1 5 V AAA dry cells To replace the batteries 1 Open the battery compartment cover by pressing the grooved section and sliding the cover downwards 2 Remove the old batteries insert two new 1 5 V AAA batteries and close the battery cover Thickness Gauge A6X30021999 06 03 2012 Battery Disposal In accordance with EU directive 2006 66 EC batteries are not to be disposed of using municipal waste disposal services Waste industrial batteries are accepted back by Siemens or by the local Siemens representative Please talk to your local Siemens contact http www automation siemens com partner or follow the return procedures of Siemens Siemens AG Industry Sector Postfach 48 48 90026 N RNBERG Thickness Gauge A6X30021999 03 2012 SIEMENS 7ME3951 0TG20 Debitmetres a ultrasons Jauge d paisseur Notice d utilisation Siemens Tous droits r serv s 2012 A6X30021999 06 03
2. Men Confirmar para introducir o confirmar el valor Resolution 1 Pulse la tecla Men Confirmar Se activa el modo Resolution Resoluci n 2 Pulse la tecla Cambiar configuraci n o Incrementar n mero indicado para seleccionar la resoluci n y la unidad 1 0 1 mm 3 Pulse la tecla Men Confirmar para introducir o confirmar el valor Indicador de grosor A6X30021999 06 03 2012 5 Anexo Anexo Velocidades de medici n de distintos materiales Material V m s V in us Aluminio 6400 0 252 Bronce 4700 0 185 Hierro fundido duro 5600 0 220 Hierro fundido blando 3500 0 138 Cobre 5010 0 197 Fibra de vidrio 2740 0 108 Vidrio 5260 6120 0 207 0 241 Lucite 2680 0 105 Niquel 6040 0 237 Nylon 2730 0 103 Policarbonato 2286 0 090 Polietileno LDPE 1950 0 070 Polietileno HDPE 2460 0 097 Poliestireno 2350 0 092 PVC 2395 0 094 Acero 5920 0 233 Acero inoxidable 5740 0 226 Titanio 5990 0 237 Agua 1490 0 059 Zinc 4210 0 165 Indicador de grosor A6X30021999 06 03 2012 Datos t cnicos Anexo Descripci n Unidad de visualizaci n Datos LCD 128x32 con retroiluminaci n Frecuencia de medici n 5 Hz Velocidad de medici n 1000 9999 m s 3 280 a 32 805 ft s Rango de medida 1 0 200 mm 0 04 a 7 99 pulgadas Resoluci n 0 1 mm 0 01 mm 0 01 in 0 001 in Tolerancia 0 65 9 99 mm 0 04 mm 1
3. 165 Jauge d paisseur A6X30021999 06 03 2012 Caract ristiques techniques Annexe Description Unit d affichage Caract ristiques 128x32 LCD avec r tro clairage Fr quence de mesure 5 Hz Vitesse 1000 9999 m s 3 280 a 32 805 ft s Plage de mesure 1 0 a 200 mm 0 04 a 7 99 inches R solution 0 1 mm 0 01 mm 0 01 in 0 001 in Tol rance 0 65 9 99 mm 0 04 mm 10 99 99 mm 0 1 0 04 mm 100 250 mm 0 03 Alimentation lectrique Deux cellules s ches 1 5 V AAA Taille 61w x 108h x 28d mm 2 4w x4 3h x 1 1d in Poids 150g 5 3 oz avec batteries Temp rature de fonctionnement 10 C a 50 C 14 F a 122 F Temp rature de stockage 20 C a 60 C 4 F a 140 F Types de sonde et plage de mesure Sonde standard PT 08 5 0 MHz plage de mesure 1 0 200 mm 04 7 9 inches Remplacement Elimination des batteries Remplacer les batteries La jauge d paisseur utilise deux cellules seches 1 5 V AAA Pour remplacer les batteries 1 Ouvrez le couvercle du compartiment de batteries en appuyant sur la partie rainur e et faites glisser le couvercle vers le bas 2 Retirez les anciennes batteries ins rez deux nouvelles batteries 1 5 V AAA et refermez le couvercle du compartiment de batteries Jauge d paisseur A6X30021999 06 03 2012 Annexe Elimination des piles Conform ment la directive
4. 2012 Introduction Avant propos Ces instructions contiennent toutes les informations n cessaires a l utilisation de l appareil Ces instructions s adressent aux personnes charg es de l installation m canique du raccordement lectrique de la configuration des param tres et de la mise en service de l appareil ainsi qu aux ing nieurs de maintenance Remarque Nous avons v rifi le contenu de ces instructions quant leur conformit avec l appareil d crit mais des variations restent possibles et nous ne pouvons garantir la conformit totale Le num ro de r f rence Siemens pour cette unit est le suivant 7ME3951 0TG20 Jauge d paisseur 2 A6X30021999 06 03 2012 Fonctionnement Fonctionnement Utilisation de la jauge d paisseur ON OFF ESC Change Setting Calibration Menu Confirm Increase Symbolized Number Backlight Switch gt gt El Jauge d paisseur A6X30021999 06 03 2012 3 Fonctionnement Mise sous tension Pressez la touche On Off pour mettre la jauge sous tension La jauge affiche successivement e Logo Siemens e Numero de r f rence MLFB et version logicielle La jauge passe en mode de mesure et affiche e 0 0mm 0 00mm 0 00in 0 000in selon l unit utilis e en dernier e Vitesse et sonde s lectionn e Allumer teindre le r tro clairage e Pressez la touche Change Setting Calibration le r tro clairage s allume e Pressez de nouv
5. OFF ESC Cambiar configuraci n calibraci n Men Confirmar Incrementar n mero indicado Interruptor para retroiluminaci n gt El Indicador de grosor A6X30021999 06 03 2012 Funcionamiento Conexi n Pulse la tecla On Off para conectar el indicador En el display del indicador aparecer sucesivamente e Logo de Siemens e Referencia MLFB y versi n del software El indicador cambiar seguidamente al modo de medici n y visualizar e 0 0mm 0 00mm o bien 0 00in 0 000in dependiendo de la ltima unidad utilizada e Velocidad de medici n y sonda seleccionada Retroiluminaci n ON OFF e Pulsando la tecla Cambiar configuraci n calibraci n se activa la retroiluminaci n ON e Pulsando nuevamente la tecla Cambiar configuraci n calibraci n se desactiva la retroiluminaci n OFF Medici n Existen tres maneras de pasar al modo de medici n 1 Conectando el indicador 2 Pulsando la tecla de conexi n On OFF para salir de MENU 3 Medici n Calibraci n El indicador debe calibrarse en los casos siguientes al conectarlo por primera vez ON si se indica un valor diferente de 4 00mm a una velocidad de 5920 m s o en caso de realizar una medici n con un bloque de prueba acoplado al indicador donde el valor correcto deber a ser 4 00mm o con otro bloque de prueba est ndar Para calibrar el indicador pulse la tecla Calibraci n El indicador visualizar la misma informa
6. de l UE 2006 66 CE les piles ne doivent pas tre jet es avec les d chets domestiques Siemens ou le repr sentant Siemens local acceptent les retours de batteries industrielles usag es Veuillez prendre contact avec votre interlocuteur Siemens local http www automation siemens com partner ou suivez les proc dures de retour de Siemens Siemens AG Industry Sector Postfach 48 48 90026 N RNBERG Jauge d paisseur A6X30021999 03 2012 SIEMENS 7ME3951 0TG20 Caudalimetros ultras nicos Indicador de grosor Instrucciones de manejo resumidas Siemens Reservados todos los derechos 2012 A6X30021999 06 03 2012 Introducci n Introducci n Pr logo Estas instrucciones contienen toda la informaci n que usted necesita para utilizar este dispositivo Las instrucciones est n dirigidas tanto a las personas que realizan la instalaci n mec nica del dispositivo conect ndolo electr nicamente configurando los par metros y llevando a cabo la puesta en marcha inicial como a los ingenieros de servicio y mantenimiento Nota Si bien hemos verificado la concordancia del contenido de las instrucciones con el dispositivo descrito puede haber variaciones por lo que no podemos garantizar una concordancia absoluta La referencia de Siemens para este dispositivo es 7ME3951 0TG20 Indicador de grosor 2 A6X30021999 06 03 2012 Funcionamiento Funcionamiento Funcionamiento del indicador de grosor ON
7. e Siemens Logo e Bestellnummer MLFB und Softwareversion Das Messger t wechselt anschlie end in die Betriebsart Messen und zeigt Folgendes an e 0 0 mm 0 00 mm bzw 0 00 in 0 000 in je nach zuletzt verwendeter Einheit e Messgeschwindigkeit und gew hlter Messkopf Hintergrundlicht EIN AUS e Durch Dr cken der Taste f r Einstellung ndern Kalibrierung schalten Sie die Hintergrundbeleuchtung EIN e Durch erneutes Dr cken der Taste f r Einstellung ndern Kalibrierung schalten Sie die Hintergrundbeleuchtung AUS Messung Es gibt drei M glichkeiten die Betriebsart Messen aufzurufen 1 Das Messger t einschalten 2 Durch Dr cken der EIN AUS Taste das Men verlassen 3 Messung Kalibrierung Das Messger t muss in folgenden F llen kalibriert werden Beim ersten Einschalten des Messger ts oder wenn bei einer Messgeschwindigkeit von 5 920 m s ein von 4 00 mm abweichender Fehlerwert angezeigt wird oder wenn Sie eine Messung mit einem am Messger t angebrachten Pr fk rper bei der der korrekte Wert 4 00 mm betragen muss vornehmen oder wenn Sie eine Messung mit einem anderen Standard Pr fk rper vornehmen Zum Kalibrieren des Messger tes die Taste f r Kalibrierung dr cken Das Messger t zeigt dann dieselben Informationen an wie oben angegeben f hrt die entsprechenden Schritte aus und wird anschlie end automatisch kalibriert Einstellungen Dr cken Sie die Taste f r Men Best tigen Auf dem Di
8. 0 99 99 mm 0 1 0 04 mm 100 250 mm 0 03 Alimentaci n Dos pilas secas de 1 5 V AAA Dimensiones 61an x 108al x 28prof mm 2 4an x4 3al x 1 1prof in Peso 150g 5 3 oz con pilas Temperatura de servicio 10 C a 50 C 14 F a 122 F Temperatura de almacenamiento 20 C a 60 C 4 F a 140 F Tipos de sonda y rango de medida Sonda est ndar rango de medida PT 08 5 0 MHz 1 0 200 mm 0 04 a 7 9 pulgadas Sustituci n eliminaci n de las pilas Sustituci n de las pilas El indicador de grosor utiliza dos pilas secas de 1 5 V AAA Para sustituir las pilas 1 Abra la tapa del compartimento de pilas presionando la secci n ranurada y desplazando la tapa hacia abajo 2 Retire las pilas antiguas inserte dos pilas nuevas de 1 5 V AAA y cierre la tapa del compartimento Indicador de grosor A6X30021999 06 03 2012 Anexo Eliminaci n de las pilas De conformidad con la directiva europea 2006 66 CE no est permitido eliminar las pilas a trav s de los servicios municipales de eliminaci n de desechos Las pilas industriales usadas son aceptadas por Siemens o por el representante Siemens de su localidad P ngase en contacto con el representante local de Siemens http www automation siemens com partner o siga los procedimientos de devoluci n de Siemens Siemens AG Industry Sector Postfach 48 48 90026 N RNBERG Indicador de grosor A6X30
9. 021999 03 2012
10. SIEMENS 7ME3951 0TG20 Ultrasonic Flowmeters Thickness Gauge Compact User Manual Siemens All rights reserved 2012 A6X30021999 06 03 2012 SIEMENS 7ME3951 0TG20 Ultraschall Durchflussmessgerate Dickenmessgerat Kompaktbedienanleitung Siemens Alle Rechte vorbehalten 2012 A6X30021999 06 03 2012 Einleitung Einleitung Vorwort Die folgenden Anweisungen enthalten alle zum Einsatz des Ger tes erforderlichen Informationen Diese Anweisungen sind zum einen f r Personal gedacht welches das Ger t mechanisch installiert elektronisch anschlie t es parametriert und in Betrieb nimmt und zum anderen f r technisches Service und Instandhaltungspersonal Hinweis Wir haben den Inhalt dieser Anweisungen auf Ubereinstimmung mit dem beschriebenen Ger t gepr ft Dennoch k nnen Abweichungen nicht ausgeschlossen worden so dass wir f r die vollst ndige bereinstimmung keine Gew hr bernehmen Die Siemens Bestellnummer f r dieses Ger t lautet 7ME3951 0TG20 Dickenmessger t 2 A6X30021999 06 03 2012 Betrieb Betrieb Betrieb des Dickenmessger tes EIN AUS ESC Einstellung ndern Kalibrierung Men Best tigen Dargestellte Zahl erh hen Schalter f r Hintergrundbeleuchtung gt El Dickenmessger t A6X30021999 06 03 2012 3 Betrieb Einschalten Zum Einschalten des Messgerats Ein Aus Taste dr cken Auf dem Display erscheint nun nacheinander
11. ci n indicada m s arriba efectuar los pasos correspondientes y despu s se calibrar autom ticamente Configuraci n Pulse la tecla Men Confirmar En el display del indicador aparecer 1 Measurement Velocity Rate 2 3 Probe Setting 4 Resolution 5 Default Indicador de grosor 4 A6X30021999 06 03 2012 Funcionamiento Velocity Rate e Setting Velocity 1 Pulse la tecla Men Confirmar Se activa el modo Setting velocity Graduar velocidad 2 Pulse Cambiar configuraci n o Incrementar n mero indicado para cambiar la velocidad de medici n 3 Pulse la tecla Men Confirmar para introducir o confirmar el valor e Velocity Measurement Sirve para medir el grosor de una muestra conocida 1 Pulse la tecla Men Confirmar Se activa el modo Velocity measurement Medici n de velocidad 2 Pulse Cambiar configuraci n o Incrementar n mero indicado para avanzar o retroceder hasta el valor de velocidad con el que se mostrar el grosor real de la muestra que se est midiendo 3 Pulse nuevamente la tecla Men Confirmar El indicador almacenar la velocidad de medici n autom ticamente Probe Setting El indicador ofrece un tipo de sonda 1 Pulse la tecla Ment Confirmar Se activa el modo Probe selecting Selecci n sonda 2 Pulse la tecla Cambiar configuraci n o Incrementar n mero indicado para seleccionar la sonda 3 1 sonda normal PT 08 4 Pulse la tecla
12. ctor Postfach 48 48 90026 N RNBERG Dickenmessger t A6X30021999 03 2012 Introduction Preface These instructions contain all the information you need for using the device The instructions are aimed both at persons mechanically installing the device connecting it electronically configuring the parameters and commissioning it as well as service and maintenance engineers Note We have verified the contents of the instructions for agreement with the device described but variations remain possible and we cannot guarantee full agreement Siemens part number for this unit is 7ME3951 0TG20 Thickness Gauge 2 A6X30021999 06 03 2012 Operation Operation Operating The Thickness Gauge ON OFF ESC Change Setting Calibration Menu Confirm Increase Symbolized Number Backlight Switch gt El k gt Thickness Gauge A6X30021999 06 03 2012 3 Operation Switch On Press the On Off key to turn on the gauge The gauge will consecutively display e Logo Siemens e Part Number MLFB and software version The gauge will then enter into the measuring mode and display e 0 0mm 0 00mm 0 00in 0 000in depending on the last used e Velocity rate and selected probe Backlight ON OFF e Press the Change Setting Calibration key the backlight is ON e Press the Change Setting Calibration key again the backlight is OFF Measurement There are three ways to go into the measuring mode 1 Swi
13. eau la touche Change Setting Calibration le r tro clairage s teint Mesure Il y a trois moyens de passer en mode de mesure 1 Allumez la jauge 2 Pressez la touche On OFF pour sortir du MENU 3 Measurement Calibrage La jauge a besoin d tre calibr e la premi re mise sous tension de la jauge ou si une valeur erron e apparait au lieu de 4 00mm pour une vitesse gale a 5920 m s ou si vous effectuez une mesure d un bloc de test attach a la jauge dont la valeur devrait tre 4 00mm ou sur un autre bloc de test standard Pour calibrer la jauge pressez la touche Calibration La jauge affichera les informations ci dessus fonctionnera avec ces param tres et se calibrera automatiquement Configuration Pressez la touche Menu Confirm La jauge affichera 1 Measurement Velocity Rate 2 3 Probe Setting 4 Resolution 5 Default Jauge d paisseur 4 A6X30021999 06 03 2012 Fonctionnement Velocity Rate e Setting Velocity 1 Pressez la touche Menu Confirm pour passer au mode Setting velocity 2 Pressez la touche Change Setting ou Increase Symbolized Number pour changer de vitesse 3 Pressez la touche Menu Confirm pour entrer ou confirmer la saisie e Velocity Measurement Mesurer l paisseur d un chantillon connu 1 Pressez la touche Menu Confirm pour passer au mode Velocity measurement 2 Pressez la touche Change Setting ou Increase Symbolized Number pour s lectionne
14. l sung 0 1 mm 0 01 mm 0 01 In 0 001 In Toleranz 0 65 9 99 mm 0 04 mm 10 99 99 mm 0 1 0 04 mm 100 250 mm 0 03 Stromversorgung Zwei 1 5 V Trockenbatterien Typ AAA Ma e 61B x 108H x 28T mm 2 4B x4 3H x 1 1T In Gewicht 150 g 5 3 oz mit Batterien Betriebstemperatur 10 C bis 50 C 14 F bis 122 F Lagertemperatur 20 C bis 60 C 4 F bis 140 F Messkopftypen und Messbereich Standardmesskopf Messbereich PT 08 5 0 MHz 1 0 200 mm 0 04 bis 7 9 Inch Batteriewechsel entsorgung Batteriewechsel Der Dickenmesser nutzt zwei 1 5 V Trockenbatterien vom Typ AAA So wechseln Sie die Batterien 1 Offnen Sie den Deckel des Batteriefachs indem Sie auf den gekerbten Bereich dr cken und den Deckel nach unten schieben 2 Entnehmen Sie die alten Batterien legen Sie zwei neue 1 5 V Trockenbatterien vom Typ AAA ein und schlie en Sie den Deckel des Batteriefachs Dickenmessger t A6X30021999 06 03 2012 Anhang Batterieentsorgung Gem der EU Richtlinie 2006 66 EG d rfen Batterien nicht ber das st dtische Abfallentsorgungssystem entsorgt werden Unbrauchbare industrielle Batterien werden von Siemens oder dem rtlichen Siemens Ansprechpartner zur ckgenommen Bitte wenden Sie sich an Ihren rtlichen Siemens Ansprechpartner http www automation siemens com partner oder befolgen Sie die R ckgabeverfahren von Siemens Flow Instruments Siemens AG Industry Se
15. ler Messkopf PT 08 4 Dr cken Sie zum Eingeben bzw Best tigen des Wertes die Taste f r Ment Bestatigen Resolution 1 Dr cken Sie die Taste f r Men Best tigen Die Betriebsart Resolution Aufl sung wird aktiviert 2 Dr cken Sie zum Ausw hlen der Aufl sung und der Einheit 1 0 1 mm die Taste f r Einstellung ndern oder Dargestellte Zahl erh hen 3 Dr cken Sie zum Eingeben bzw Best tigen des Wertes die Taste f r Ment Bestatigen Dickenmessgerat A6X30021999 06 03 2012 5 Anhang Anhang Messgeschwindigkeiten fur verschiedene Materialien Material V m s V in us Aluminium 6400 0 252 Messing 4700 0 185 Gusseisen hart 5600 0 220 Gusseisen weich 3500 0 138 Kupfer 5010 0 197 Glasfaser 2740 0 108 Glas 5260 6120 0 207 0 241 Lucite 2680 0 105 Nickel 6040 0 237 Nylon 2730 0 103 Polycarbonat 2286 0 090 Polyethylen LDPE 1950 0 070 Polyethylen HDPE 2460 0 097 Polystyrol 2350 0 092 PVC 2395 0 094 Stahl 5920 0 233 Edelstahl 5740 0 226 Titan 5990 0 237 Wasser 1490 0 059 Zink 4210 0 165 Dickenmessger t 6 A6X30021999 06 03 2012 Technische Daten Anhang Beschreibung Anzeigeeinheit Daten 128 x 32 LCD mit Hintergrundbeleuchtung Messfrequenz 5 Hz Messgeschwindigkeit 1 000 9 999 m s 3 280 bis 32 805 ft s Messbereich 1 0 200 mm 0 04 bis 7 99 Zoll Auf
16. ovides one type of user probe 1 Press Menu Confirm key into Probe selecting state 2 Press Change Setting or Increase Symbolized Number key to select probe 3 1 normal probe PT 08 4 Press Menu Confirm key to Enter Confirm Resolution 1 Press Menu Confirm key into Resolution state 2 Press Change Setting or Increase Symbolized Number key to select resolution and unit 1 0 1 mm 3 Press Menu Confirm key to Enter Confirm Thickness Gauge A6X30021999 06 03 2012 5 Appendix Velocity Rates of Various Materials Material V m s V in us Aluminum 6400 0 252 Brass 4700 0 185 Cast Iron Hard 5600 0 220 Cast Iron Soft 3500 0 138 Copper 5010 0 197 Fiberglass 2740 0 108 Glass 5260 6120 0 207 0 241 Lucite 2680 0 105 Nickel 6040 0 237 Nylon 2730 0 103 Polycarbonate 2286 0 090 Polyethylene LDPE 1950 0 070 Polyethylene HDPE 2460 0 097 Polystyrene 2350 0 092 PVC 2395 0 094 Steel 5920 0 233 Stainless Steel 5740 0 226 Titanium 5990 0 237 Water 1490 0 059 Zinc 4210 0 165 Thickness Gauge A6X30021999 06 03 2012 Appendix Technical Data Description Display Unit Data 128x32 LCD with backlight Measuring Rate 5 Hz Velocity Rate 1000 9999 m s 3 280 to 32 805 ft s Measuring Range 1 0 200 mm 0 04 to 7 99 inches Resolution 0 1 mm 0 01 mm 0 01 in 0 001 in Tolerance 0 65
17. r la valeur de la vitesse en vue de d terminer si l paisseur est la m me que celle de l chantillon mesur 3 Pressez de nouveau la touche Menu Confirm La jauge sauvegardera automatiquement la vitesse Probe Setting La jauge fournit un type de sonde utilisateur 1 Pressez la touche Menu Confirm pour passer au mode Probe selecting 2 Pressez la touche Change Setting ou Increase Symbolized Number pour s lectionner la sonde 3 1 normal probe PT 08 4 Pressez la touche Menu Confirm pour entrer ou confirmer la saisie Resolution 1 Pressez la touche Menu Confirm pour passer au mode Resolution 2 Pressez la touche Change Setting ou Increase Symbolized Number pour s lectionner la r solution et l unit 1 0 1 mm 3 Pressez la touche Menu Confirm pour entrer ou confirmer la saisie Jauge d paisseur A6X30021999 06 03 2012 5 Annexe Annexe Vitesses de diff rents mat riaux Mat riau V m s V in us Aluminium 6400 0 252 Laiton 4700 0 185 Fonte dure 5600 0 220 Fonte molle 3500 0 138 Cuivre 5010 0 197 Fibre de verre 2740 0 108 Verre 5260 6120 0 207 0 241 Lucite 2680 0 105 Nickel 6040 0 237 Nylon 2730 0 103 Polycarbonate 2286 0 090 Polyethylene PEBD 1950 0 070 Polyethylene PEHD 2460 0 097 Polystyrene 2350 0 092 PVC 2395 0 094 Acier 5920 0 233 Acier inoxydable 5740 0 226 Titanium 5990 0 237 Eau 1490 0 059 Zinc 4210 0
18. splay erscheint nun Measurement Velocity Rate Probe Setting Resolution Default OPO NES Dickenmessger t 4 A6X30021999 06 03 2012 Betrieb Velocity Rate e Setting Velocity 1 Dr cken Sie die Taste fur Men Best tigen Die Betriebsart Setting velocity Messgeschwindigkeit einstellen wird aktiviert 2 Driicken Sie zum ndern der Messgeschwindigkeit die Taste fiir Einstellung ndern oder Dargestellte Zahl erh hen 3 Dr cken Sie zum Eingeben bzw Best tigen des Wertes die Taste f r Men Best tigen e Velocity Measurement Dient zum Messen der Dicke eines bekannten Pr flings 1 Dr cken Sie die Taste f r Men Best tigen Die Betriebsart Velocity Measurement Geschwindigkeitsauswahl wird aktiviert 2 Dr cken Sie die Taste f r Einstellung ndern oder Dargestellte Zahl ndern um aufw rts oder abw rts zu dem Geschwindigkeitswert zu bl ttern bei dem die tats chliche Dicke des gemessenen Pr flings angezeigt wird 3 Dr cken Sie erneut die Taste f r Men Best tigen Das Ger t speichert automatisch den Wert f r die Messgeschwindigkeit Probe Setting Auswahl Messkopf Das Messger t verf gt ber eine Art von Messkopf 1 Dr cken Sie die Taste f r Men Best tigen Die Betriebsart Probe selecting Auswahl Messkopf wird aktiviert 2 Dr cken Sie zum Ausw hlen des Messkopfs die Taste f r Einstellung ndern oder Dargestellte Zahl erh hen 1 norma
19. tch on the gauge 2 Press power key On OFF to escape from MENU 3 Measurement Calibration When the gauge is initially switched ON or if an error value instead of 4 00mm appears when velocity rate is 5920 m s or if you take a measurement of a test block attached on the gauge where the correct value should be 4 00mm or on another standard test block then the gauge needs to be calibrated To calibrate the gauge press the Calibration key The gauge will display the same information listed above operate according to that information and then the gauge automatically calibrate Set up Press Menu Confirm key The gauge will display 1 Measurement 2 Velocity Rate 3 Probe Setting 4 Resolution 5 Default Thickness Gauge 4 A6X30021999 06 03 2012 Operation Velocity Rate e Setting Velocity 1 Press Menu Confirm key into Setting velocity state 2 Press Change Setting or Increase Symbolized Number key to change velocity rate 3 Press Menu Confirm key to Enter Confirm e Velocity Measurement Measuring the thickness of a known sample 1 Press Menu Confirm key into Velocity measurement state 2 Press Change Setting or Increase Symbolized Number key to scroll up and down for the value of velocity to determine the thickness is the same as the value of the sample being measured 3 Press Menu Confirm key again The gauge will store the velocity rate automatically Probe Setting The gauge pr

Download Pdf Manuals