Home
User manual - Easysecuritymarket.com
Contents
1. Manager password 2 ID number To deleteusers continuously Manager password 2 1D number ID number ID number 2 3 By Manager fingerprints n programming mode Press 1 1 input fingerprint twice 2 input another fingerprint twice D number 1 Manager add fingerprint D number 2 Manager delete fingerprint The first Fingerprint Manager add Fingerprint itis to add theusers The second Fingerprint Managerdelete Fingerprint it isto delete users To addone user Press Manager add Fingerprint Input UserFingerprint twice RepeatManager add Fingerprint Note input the user s fingerprint twice during which the light shines red then turn green means the Fingerprint is added successfully A
2. To addusers continuously Reliable Durable Affordable Press manager s add fingerprint 1 user fingerprint 2 user fingerprint 3 user fingerprint N User Fingerprint Manager s add fingerp rint Resetting to factory default setting Turn off the power press the reset key SW1 on the PCB keep holding it and re power the device SB 7500 will give three shortbeeps means reset to factory setting successfully then move more your finger off from the reset key It is to revert all settings to the factory default setting but the users data enroled is safe Croshax When add user the fingerprints ID number willauto add from3 120 To deleteusers Press manager s delete fingerprint 1 user fingerprint 2 user fingerprint 3 user fingerprint N User Fingerprint Manager s delete fingerprint Simplified Instruction Function description Choose from the relevant functions below and input Enter the programming mode 9999 then you cando the programming 9999 is the default factory master code change the mastercode 0 newcode repeat the new code code 4 digit Add user 7 Fingerprint repeat Fingerprint can add Fingerprints continuously Delete user 8 Fingerprint can delete Fingerprints continuously Exit from theprogramming
3. Fingerprint amp Door Acess machine F007 1 Infrared remote control keypad User Manual F007 Security Screws 3mmX7 5mm Screw driver Used for front case and back case Self tapping screws 4mmx25mm Used for fixing Pastern stopper 6mmxX25mm Used for fixing Croshax Reliable Durable Affordable CFX SB 7500 Stand Alone Biometric Reader User manual Introduction SB 7500 use the precise electron circuit and good productive technology which is the metal structure fingerprint amp access machine This machine uses the most advanced fingerprint identification technology very safety Which is the most ideal choose It is widely used in business affairs organization office factory housing district etc This product s programming is done by the infrared remote control keypad or fingerprint manager This product maximum can store 120 fingerprints There are 2 fingerprint managers and eachfingerprint has one ID code Specifications Sleeping function When this machine in stay status it will auto enter sleep status This can reduce power dissipation and prolongthe machine s uselife Manager infrared remote control keypad Users use infrared remote control keypad when enter the programming mode they can operate as follow Changing manager code Add fingerprints Delete fingerprints Delete all fingerprints release alarm Setting open door
4. 0832 2 zZ O z zZ N W O 0 T a Wiring Cakle Hamess O a O 5 Sounds and lightstatus Operation Status Red led Green led Blue led Buzzer Resetting Bright Bright Goes out Consecutive short ring Power on Slow flashing Goes out Short ring Sleeping status Slow flashing Goes out Goes out Stay status Slow flashing Goes out Quickly flashing Voided key Short ring Enter programme status Bright Goes out Programme status Goes out Input fingerprint instruct Goes out Short ring Quickly flashing Input fingerprint success Goes out Long ring Input fingerprint fail Three short ring Exit programming status Long ring Open door status Goes out Bright Goes out Long ring alarming Quickly flashing Goes out Technical Specification Quickly flashing Consecutive long ring Note means keep plain state 12VDC 10 Supply Voltage Sleeping Current lt 100mA 3A Stay Current Door Relay Resolution Fingerprint User fingerprint quantity Identification time 450 DPI input time lt 2S Temperature 20 C 55 C FAR lt 0 0001 Humidity 20 RH 95 RH FRR lt 0 01 Memory capacity 120 Dimensions 115mmx 70mmxX35mm Manager quantity 2 weight 500g Package Listing Descriptions Quantity Remark
5. gramming mode Press manager password Manager password 9999 factory defaultsetting 1 2 Changing manager code In programming mode Press 0 newpassword code Repeat new password code The manager code must be 4 digit number 2 Add anddelete Users There are 3 ways to add and delete user 1 by keypad 2 by User ID 3 by Managell Fingerprint 2 1By keypad the most convenient way Add User manager password 7 input fingerprint twice to add more thanone user justinput finger continuously Delete User managerpassword 8 inputfingerprint once to delete more thanone user justinput finger continuously Note When add fingerprint please put the Fingerprintwhich you will addon the sensor twice during which the light shines red then turngreen means the Fingerprintis added successfully when delete users justinput fingerprint once 2 2 By User ID To addone user Managerpassword 1 Dnumber Input userFingerprint_twice User ID number canbe any digit between3 120 but onelD number to oneuser Toadd users continuously Manager password 1 3 1 User Fingerprint 4 2 user fingerprint N N user fingerprint To delete one user
6. ion Drill 4 holeson the wall Thread the cable through cable hole Wiring When wiring completed attach the rear plate to the wall firmly with at least three flat head screws Plug the cable harness 6 Attach thefront cover to therear plate AUN i Note Please don t power onbefore you connect finish Install diagram p e G a Infrared Sensor Fingerprint Sensor j e L3 lt A Terminal wire connector function OPEN Yellow Open door button 12V Red 12V power input GND Black Gnd NO Blue Relay output NO COM Purple Relay output COM NC Orange Relay output NC Common powers connects diagram DE ai Open door button Common 12V 3A O z Special power supply Power on the Off power the locks keep opening 12V special power supply 12V Power on the locks keep opening Open door button Off power the locks keep opening Yellow Red 12V Black GND Blue NO COM Purple Orange NC Yellow OPEN 12V GND NO COM NC Note We adviseyou use specialadaptor itwill make yoursystem work morestable Power on When all connections are finished you can power on This time the buzzer will give a long ring and red ledflashing The machinewill enter regular workstatus Operation guide 1 Manager mode usingInfrared remote control keypad 1 1 Enter pro
7. mode How do release thedoor Fingerprint User Put the Fingeron the fingerprintsensor for 1second 3 Delete all fingerprints Press manager password 20000 Note This will deleteall fingerprints including Manager Fingerprint before this operation you need make sure the data isunuseful 4 Setting opendoor time Press manager password 4 XXI Note Open door timeis the lock keeps time XX0 10s default setting 5s 5 Exit programming mode When the operationis over you can press 6 Manager releasealarm to exit from programming mode If nopress but over 1 minute it will exit from programming mode automatically When this machine isin stay status ifit was be opened the buzzer will soundconsecutive long ring And it Will be keep on1 minute While itin the alarm status you can use eitherof the follow ways release alarm a Use Infrared remote control keypad input alarm release password the release password isthe same with managerpassword b Use manager fingerprint press mangers fingerprint either manager add fingerprint or manager delete fingerprint isok 1C aoo q SW2 Tamper switch O Q D on SW1 Reset switch SS PCB connect diagram o o o o o o O Oo O
8. time Setting release alarm Manager fingerprint operation function ID number 1 Manager add fingerprint can t open door number 1is used add users number 2 is used deleted users ID number 2 Manager delete fingerprint ID number 3 120 users fingerprint User fingerprint operation function ID number 3 120 users fingerprint are used open door Open door button operationfunction This button isused to openthe door Parma setting function Open door time 0 10s default setting 5s User can use infrared remote control keypad setting Relay out NC and COM When power off the lock isopened NO and COM When power on the lock isopened Manager release alarm When this machine isin stay status ifit was opened the buzzer will sound consecutive long ring And it willbe kept for1 minute Important information If holes are tobe drilled before mounting onto a wall checkfor hidden cables and or pipes before drilling Use safety goggles whendrilling or hammering incable clips Every effort has beenmade to provide accurateinformation however slight variationscan occur Wealso reserve the right tomake changed for productimprovement at any time A Intramural interface circuit Electric lock interface This machine use relay which makes sure this part hasn t any connect When the lock is opened the relay O closed The relay put out circuit is 2A Relay Electric lock interface Install wiring and fixat