Home
        Avitech Galaxy User Manual
         Contents
1.  VCC 8000 Users Guide  This document will cover the basic operations  of the latest VCC 8000 series module designed  for video and data monitoring  The instructions  below are designed to get you up and running  using a single module with Galaxy V3 09 with  very simple instructions on the features and  functionality of the system  Please use this  guide as a manual to setup your VCC 8000  unit   Communication  The VCC 8000 series uses the same  communication as the MCC 8000 series and  includes both an IP and serial port for control   For best results  we recommend using the IP  port for control  The default IP address of the  VCC 8000 module is set to 210 100 100 151  so to connect to it  you will need to set the IP  address of your computer to 210 100 100 150  and a subnet mask of 255 255 255 0   Change IP Address  The easiest way to change the IP address is to  logon using Galaxy  Then select Settings       Module Parameter   IP Address  Enter a new  IP address and select OK  You will be  prompted to Close Galaxy and select YES  when prompted to save  Make sure you also  change the IP address of your computer to  match the new sub domain before running  Galaxy with the new IP address   Starting Up With Galaxy  After starting the Galaxy software  you are  presented with three choices  Serial Port Fast  for communicating via RS232  User Key in IP  where the user knows the IP address of the  module and can type it in  or Automatic Detect  IP  where the user does not know the 
2. 0  series  The minimum size is roughly 144x125  pixels and the maximum size limitation is  1280x900  The latter limitation only apples  when you are manually resizing a window with  the OSD turned ON  If you turn off the OSD   Borders and Labels  then there is no  maximum size limitation and you can manually  resize to your hearts content   Saving to Flash  The flash stores the default layout for the VCC   8000 series  Once you have your windows  arranged and labeled  you can save the layout  so that it is loaded every time the module is  turned on  To save to flash  you can either quit  Galaxy and select YES when prompted to save  or you can select Save File or Load File from  the option menu and select Update to Module  Flash   Saving to Presets Layouts    Presets are custom layouts created by the  user  They save all the properties of the group  such as window position  window size  label  name  label properties  output resolution  and  baud rate  To save a preset  all you have to do  is select Save File from the Option menu and  then enter in a name for the preset  For best  results  we recommend you use numbers for  preset names so    1        2        3        4     etc  The  VCC 8000 can store up to 27 presets and  make sure to save the default preset as well so  it does not become lost  Make sure to Update  to Module Flash after saving presets or else  the information will not be saved correctly   Upgrading Firmware  Currently  there the firmware update is only for  t
3. IP  address of module and needs the software to  figure it out  Use the latter two for  communication via Ethernet  Also keep in mind  that Galaxy can only communicate with one IP  address at a time   Menu Layout  When Galaxy starts up  you will notice three  menus that make up the control software  On  the top right hand corner you will get the heads  up display  This shows you the location of  every window on a particular unit and is useful  if you have multiple units cascaded in a single    group  If you only have a single unit  then this  will be the same as the main control window  In  the center you will see the Galaxy menu which  shows all the windows that are on the module   This menu allows you to drag and drop the  window to change the position and size  The  settings menu will include the main menus that  will control all aspects of the unit   Finally on the right hand side will be the option  menu  This menu allows users to choose  between different modules to control if there  are multiple modules cascaded together  Users  can also use the Image Window and Label  Switch to quickly turn on and off certain  windows or the label to those windows  Further  down  are the save buttons that allow users to  save presets and load them at a later time   Window Layout  In the window layout menu  you will see eight  windows for the VCC 8008c  The following is a  list of Inputs to Windows so you know where  the input will show up  This is also illustrated in  the picture on p
4. age 1   Computer 1   Window 1  Computer 2   Window 3  Computer 3   Window 5  Computer 4   Window 7    Video 1   Window 2  Video 2   Window 4  Video 3   Window 6  Video 4   Window 8  Saving to Flash  The first thing you should do after loading  Galaxy and to make sure there is something  saved to the flash   To Save to Flash   1  Select Load File or Save File from the  option menu  2  Select Update to Module Flash  3  Select OK to Finish  Changing the Output Resolution  The second thing you will want to do is to set  the output resolution  Unlike Cosmos  this can  be done anytime during the setup but it is still a  good idea to do this during the beginning of the  setup process   To Change the Output Resolution   1  Select Settings   Set Output Mode  2  From the drop down menu  select the  desired output resolution  3  Select OK to initiate changes    Changing the Baud Rate  The third thing you should if you plan to use  the VCC 8000 series with a third party  controller   To change the Baud Rate   1  Select Set Com A from the option menu  2  From the Baud Rate drop down menu   select the desired baud rate  3  Select OK to initiate changes  4  Close Galaxy and select YES when  prompted to save  5  Restart Galaxy and select Set Com A  from the option menu  6  The new baud rate should be selected  Built in Layouts  There are several layouts built into Galaxy that  allows users to quickly arrange the windows to  fill the display   To Access the Default Layouts   1  Right click wi
5. he control board  CB  and the GM1601 FW for  the CB  The CB firmware uses RS232 to  Update and the GM1601 FW for the CB  requires RJ45  Ethernet   Please view the  pictures and make sure your settings are the  same  To access the firmware update menu   select Others from the Communications Mode  Menu  Do the CB first and then the GM1601  FW for CB   VCC 8000 DS80C400 hex for CB  AT VCC 8000 1601 hex for GM1601 FW CB    Special Application PIP  To use picture in picture mode  the user must  first turn off the OSD  Then drag the window to  be in the background to full screen  Do not use  the full screen command   From the option  menu  select the boxes for the windows not in  full screen to come forward  Selecting Window  2 will bring forth both 1 and 2  Selecting  Window 4 will bring forth both 3 and 4   Selecting Window 6 will bring forth both 5 and  6  And selecting Window 8 will bring forth both  7 and 8   Technical Support  If you have any questions regarding the  information provided in this guide  please call  our technical support line at 425 885 3863 or  our toll free line at 1 877 AVI TECH   To contact the author of this document  please  send an email to Thomas avitechvideo com     
6. o choose from and multiple color  combinations for the label name and  background   To Change the Label Name   1  Right click on a window and select Set  Label  2  On the first line  replace    Window      with  the desired name  3  Users can also set the Font Color  BG  Color  and Font Size  4  Select OK to initiate changes    Changing the Border Color  The 3D border for each window is made of 6  lines  These lines can be set to different colors  for a custom look  There are also eight built in  borders the user can choose from to change  the appearance of the border  The width of the  border can also be changed   To Change the Border Color   1  Select Settings   Group Parameter     Border to change the properties of all  the borders in the selected group  2  Right click on a window and select Set  Border to change the properties for the  specific window  3  Users can either create a unique border  or choose from one of the eight built in  borders  4  Select the width of the border and then  select OK to initiate changes  Full Screen  There are two ways to make a window go to  full screen mode  Users can right click on a  window and select Full Screen or they can  move the cursor to the upper right hand corner  of the window until the cursor becomes a  capital F  Left click on the capital F to make the    window full screen  Repeat the procedure to  reverse the process   Maximum Size Limitation  There is a minimum and maximum size  limitation for all windows from the VCC 800
7. thin the black space in the  control menu or on the blue bar across  the top of the control window  2  Select Group Layout and then the layout  you want  a  2x2    b  3x3  c  3x4  d  4x3  e  4x4  f  6x6  g  8x8  h  10x10  Afterwards the screen should update showing  the layout you selected   Manually Repositioning a Window  To manually reposition a window  left click and  hold to select a window like you would a  Windows application and drag it to another  location where it does not overlap another  window  Lift the left mouse button and the  window will move to the location you selected   The changes should occur in real time on the  display   Manually Resizing a Window  To manually resize a window  left click and  hold the border of a window and drag it out to  the desired size  Lift the left mouse button and  the window will resize to the shape you  dragged it to be  This is similar to resizing a  Windows application window  Make sure the    resized window does not overlap other  windows  The changes should occur in real  time on the display   Turning Windows  amp  Labels On Off  There are eight rectangular boxes on the  option menu that correlate to each one of the  windows on the display  To the right of each  rectangle is a check box for the window and  the label  Use these check boxes to turn  Windows and Labels for the associated  window On Off   Changing the Label Name  The label name can be any word phrase or  number up to 32 characters long  There are  four sizes t
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Owner`s Manual  Manual del usuario  Télécharger le fichier "vac_223_01"  1461/C3B  Tripp Lite SMART2200VS User's Manual  Canon Cannon EOS 500 D User's Manual  Olimpia Splendid Unico inverter 12 HP User Guide - E  MSG-3101  BM35700  brochure  - KW Apparecchi scientifici    Copyright © All rights reserved. 