Home
Treadmill Control Software
Contents
1. Start the pulse auto mode Switch the treadmill on and off Start the help program Measurement Data Each time the running time is reset a new measurement series is started It is not necessary to process the measurement data immediately They are temporarily stored for the duration of program use and displayed in the list in the measurement data folder The following properties are visible Start of measurement End of measurement Last name and first name of runner if a name was entered File name if the data has been exported Possible functions can be selected using the right mouse button The selected list entries can also be used by drag and drop Measurements 09 55 38 09 56 12 Mustermann Max not saved 09 54 36 09 55 15 not saved Measurements Fig 7 Measurement Data List Already run or edited programs are saved in a list in the program directory and cached for the duration of program use The following properties are visible Program name File name Program duration Program distance Possible functions can be selected using the right mouse button The selected list entries can also be used by drag and drop Protocols Protocol Name Filename Duration 1 Distance Conconi Il CONCONI2 PRG 21 17 0 H Measurements Protocols Fig 8 Program List 15 Operation 16 6 2 WOODWAY Operation Manual Operation Turn the treadmill on using the software with the POWER
2. min Total 05 km Meosuements Protocols Protocol Editon Fig 11 Program Editor Graphic Programming A click on the graphic speed display activates program input By changing the mouse position after a program step a subsequent step is displayed Only attainable parameters can be created speed sequence duration and acceleration are limited The current sequence parameters can be read in the program sequence table After the next mouse click the program prompts you to enter the corresponding incline value Then the displayed program step is accepted The display area can be changed using the 5 selection keys below the incline curve display screen Scrolls the display screen to the left Enlarges the display area in the display screen The display area is selected so that the complete program is visible in the display screen Reduces the display area in the display screen Scrolls the display screen to the right 02 2014 v1 0en For The Long Rum OODWAY 6 3 2 6 3 3 6 4 iy Set Pulse Maximum Pulse Training Condition 02 2014 v1 0en Operation Tabular Programming In addition to graphic program input values can also be entered through tabular programming Consecutive program steps can be entered in the step input table The tab key the cursor keys or the mouse can be used to navigate through the in dividual lines and columns The entered values are checked after exiting the input position an
3. E 18 6 3 2 Tabular Programming NEEN 19 6 3 3 EEGEN 19 6 4 NICK CONTO RE 19 6 5 Koeha ie WE 21 6 6 elei lale R I Ten 22 Troubleshooting RE 23 Table of el 24 3 Introduction Observe this Manual For The Long Rur WOODWAY Introduction About this Manual This user manual provides information on installing and using the treadmill control software for the WOODWAY PPS series slat belt treadmills A condition for safe operation is compliance with all safety and operating instruc tions Improper operation can cause accidents Not using the slat belt treadmill as intended according to the manufacturer s instructions can cause accidents and equipment damage gt The operating instructions supplied with the PPS treadmill and this user s manual must be read and fully understood before the equipment is used Read and observe the operating instructions and user s manual Read the PPS treadmill operating instructions and this user s manual carefully before beginning any activities on the device WOODWAY accepts no liability for accidents equipment damage and consequences of equipment failure that are a result of failure to follow the user s manual In addition the local accident prevention regulations and general safety conditions for intended use of the treadmill apply The manufacturer reserves the right to make technical changes in the context of improving the performance properties and further development without pr
4. For The Long Run WOODWAY Treadmill Control Software Manual Operation af RE as 4 vn Ma User s Manual Version 02 2014 v1 0en Manufacturer WOODWAY GmbH Steinackerstr 20 79576 Weil am Rhein Germany Tel 49 7621 940 999 0 Fax 49 7621 940 999 40 E mail info woodway de Web www woodway de Sales Tel 49 7621 940 999 10 E mail vertrieb woodway de Customer Service Tel 49 7621 940 999 14 E mail service woodway de For The Long Rum OODWAY 02 2014 v1 0en Introduction Table of Contents 1 Ilaiu gela lE COON D 4 1 1 KEE 4 1 2 WISE UG E 5 1 3 Limitation of tr DINGY EE 5 1 4 KENE 5 1 5 C stomer ENEE 6 Notces on the EE 7 2 1 Areas of Application dee 7 2 2 OPS of EEN 7 2 3 Sy tem Regul SING e sense cece see cones a r 7 Ee 8 3 1 Description Of Warning Notices EE 8 3 2 Safety before Use ee 8 aleet 9 4 1 USB to Serial Converter NEEN 9 A Ag Technical Data E 9 4 1 2 System Requirements e ekNRNEREKN KSE EN NENNEN NEEN RRE e 9 4 1 3 Driver vcs secscsesavenscsecscvensavaveusenscveneuvavausenesseneusararsusensszes 10 4 2 elei wee 10 Software Description s s sesssssssrsrrrrrrrrrsrnrnrnrnrnrnrnererenrnnnnrnrnenrnrnenenennne 12 5 1 Installation 1 er rn nn 12 5 2 ln e E E N A E E EE 12 5 3 M EL a E E E E A E ee 14 5 4 ill 14 5 9 Measurement D E 15 IN le ee 16 6 1 DEELER 16 6 2 Program SEQUENCE ene EEEREN 16 6 3 Program Editor EE 17 6 3 1 Graphic Programming E
5. at should be generated The following additional data format adjustments can be made under the Format tab e Separator between the output columns Tab or space e Decimal separator Comma or decimal point e Runner data include Storage including runner data difficult data import in other programs or sole data export of measurement data e Export interval Here the time interval between the exported data sets can be selected Possible intervals are 100Hz 50Hz 25Hz 10Hz 250ms 500ms 1s 5s 10s 15s 30s 60s These settings also remain available for new data exports and must only be changed if a different export format should be generated 21 Operation 6 6 Printing Measurement Data Printing Running Programs 22 For The Long Rur WOODWAY Printing Options Before printing begins the printing options window appears Here the printing op tions can be selected A graphic or tabular representation is shown Print Options Printer Name Canon MX700 series Printer Port USBO02 Type of Output Order 1 Speed Ei CG Graphic diagram 2 Inclination 2 C Tabular text 3 Heattrate Fig 15 Printing Options Screen The measured values e g speed incline pulse rate can be sent to the printer in edited form Before printing additional information runner s name date of birth can be added to the measured data In the print options window the desired measurement parameters maxi
6. ating instructions Use by non authorized persons Use of replacement parts which were not approved by WOODWAY GmbH Unauthorized modifications to the device or accessories The WOODWAY GmbH general terms and conditions and delivery conditions apply as well as the legal regulations valid at the time of contract conclusion 1 4 Copyright The release of the user s manual to third parties without the written permission of WOODWAY GmbH is prohibited All contents text drawings images or other illustrations are copyright protected and are subject to intellectual property rights Any misuse is punishable by law Duplication in any manner and form including excerpts as well as use and or communication of the content are not permitted without written permission from WOODWAY GmbH 02 2014 v1 0en 5 For The Long Rur Introduction LWW WAY 1 5 Customer Service For service questions please contact the manufacturer as follows WOODWAY GmbH Steinackerstr 20 79576 Weil am Rhein GERMANY Contact Tel 49 0 7621 940 999 14 Fax 49 0 7621 940 999 40 E mail service woodway de For faster processing of your request please have the following data and infor mation available Information on the nameplate specific model serial number An accurate description of the circumstances What action has already been taken 6 02 2014 v1 0en For The Long Rum OODWAY 02 2014 v1 0en 2 2 2 3 Notices on
7. button and wait until the device is ready for operation If the treadmill is to be operated in manual mode select this function using the manual operation key in the toolbar Manual Operation appears on the main screen tion Manual Opera et Ka EH Se A fw Mi Wl Le Cap KA PS gt TA i P gt s Sc x s DC el i s g mt d A o a P RS wat x D 8 a eh aed y 5 d 7 WEN mn me ZA RK Zeg Se o TTo a e ame 2 Vd EE eg fin E EE Measurements Protocols Manual Operation Fig 9 Manual Operation The treadmill speed and incline keys are displayed on the screen Speed and incline values can be entered directly using the keys The stop key is used to stop the treadmill Use the exit key to return to the starting state in which e g a program can be started Program Sequence When a running program is loaded a program sequence file is activated After the program has been completely loaded the start key can be selected in this file The start time can be set using the horizontal scroll bar or can be changed di rectly in the input field It is also possible to enter a pulse limit by entering or changing the maximum allowable pulse in the maximum pulse input field While the program is running the speed and incline of the running program can be changed manually if necessary e g using the railing keyboard A modified running program which can be used separately is then created in the progra
8. d changed if nec essary If the input step data is complete the program step is checked again and tested to see if it is compatible with the preceding and subsequent program steps After that the program step is displayed in the graphic displays for speed and in cline It is possible to insert steps before the current program step or to delete current program step For this the Insert and Delete keys to the right of the step table are used Maximum Pulse It is possible to enter a maximum pulse limit If the pulse limit is exceeded the treadmill control stops the running program Pulse Control The treadmill is equipped with a function with which the device is controlled based on the entered pulse value This function is started by pressing the Automatic Pulse Mode in the toolbar It is necessary to enter some pulse control parameters in advance The parameters can be changed at any time Settings of HR Control Self Assessment Maximum Speed Minimum Speed Maximum Inclination Minimum Inclination Cancel Fig 12 Parameter Automatic Pulse Mode The control will try to maintain the heart frequency value If this value is exceeded the treadmill will stop It should not be set too close to the target pulse but in the health safe pulse rate range This assessment is responsible for the rate of change for speed and incline Possible values are between 1 poor condition and 9 excellent condition Under extreme fluctua
9. die Sprache aus die wahrend der installation benutzt werden soll Fig 3 Setup Administrator rights are needed for software installation Installation under a limited user account will be terminated with an error message Perform the installation step by step Only use the installation path proposed by the software e g C Programs Woodway StandardPLUS 5 2 Settings For the program to function properly the following basic settings are needed e Make sure that the number of the serial COM port 1 4 in the WOODWAY treadmill control software is set correctly This information is the most im portant basic program setting without which a connection to the treadmill cannot be established Select the name of the interface where the treadmill is connected in the hard ware folder If the wrong number is selected an error message appears later in the program with the option to correct the entry 12 02 2014 v1 0en For The Long Run OODWAY 02 2014 v1 0en Software Description Datei Aktion Ansicht e 8 CS ZS LAPTOP MB A Anschl sse COM und LPT EI Bluetooth Kommunikationsanschluss COM3 F Bluetooth Kommunikationsanschluss COM6 aJ RIM Virtual Serial Port v2 COM11 a RIM Virtual Serial Port v2 COM12 Audio Video und Gamecontroller gt 8 y Batterien Programmeinstellungen Bildbearbeitungsgerate Gy Biometric Software Bluetooth Gerate Schnittstelle Ereignismodus Computer v akti
10. en On the main screen the current treadmill values are displayed and the various pro gram functions can be selected After the software is started lists for measurement data and programs can also be selected If the treadmill has event control an additional directory for events appears Gi WOODWAY Protocols TER Measurement Manual Operation Protocol HR Control Power Settings Help Inclination Distance Time Heartrate Strain Isak Protocols Measurements Protocols Fig 6 Main Screen Operating Keys The function key is located in the toolbar The function is started by pressing the respective key With some keys additional occupancy is possible by list entry drag and drop The function is then executed in combination with the data from the list entry Ends the WOODWAY treadmill control program Print measured values or a running program lcon Drop Print measured values or the running program shown as an Icon Start the program editor for creating programs Icon Drop Start the program editor to edit a running program shown as an Icon Start the event editor for creating events lcon Drop Start the event editor to edit an event shown as an Icon Upload an event Icon Drop Upload the event shown as an Icon Start manual mode 02 2014 v1 0en For The Long Run OODWAY 02 2014 v1 0en fi A E 5 5 Software Description Start a running program Icon Drop Start a running program shown as an Icon
11. ermined target pulse It is still possible to adjust the speed and incline manually 02 2014 v1 0en For The Long Rum OODWAY 02 2014 v1 0en 6 5 Operation Data Export The program makes it possible to export the measured data in a variable ASCII format or in the POLAR company format HRMO and HRM1 The following describes the ASCII format ASCII File Values Format Not Exported Values Exported Values Time mm ss Time s Speed m s Speed km h ka Distance km m Include gt Z Inclination SI T Altitude m System time hh mm ss lt Exclude PY Hearttrate bpm Cancel Fig 14 Data Export ASCII Format Sequence of Actions 1 When the treadmill stops the obtained values are saved in the measurement data file Select the desired measurement line from this file The data can be exported by right clicking the entry 2 Select the data name and data type here the ASCII must be selected 3 The values to be exported must be chosen from the available measurement da ta speed incline load etc from the values folder on ASCII file format screen This is done by pasting these values in the Exported values list Through the sequence as viewed from top to bottom it is possible to arrange the order of the output value columns in the exported file NOTE The selected settings remain available for new data exports and must only be changed if a different export form
12. ged Replace interface wire if necessary contact WOODWAY customer service and order interface wire If other malfunctions occur or the malfunction is not corrected contact WOODWAY customer service as follows e Tel 49 7621 940 999 14 E mail service woodway de 02 2014 v1 0en 23 Table of Figures 24 For The Long Rum Table of Figures Fig Fig Fig Fig Fig Fig Fig Fig Fig Fig Fig Fig Fig Fig Fig WOODWAY USB to Serial Adapter Manufacturer ATEN Model UC 232A 00008 9 RS 232 Interface Wire 2x D SUB 9 pin Configured cccceeeeeeeeees 10 Ee 12 Interface in the Device Manager due to operating system figure in German erctictinewsnencsposerncnsncarsnansenonenontencedinensnenaccesntepcssnronsrerndeusearaedia 13 Program Settings E 13 Ma SCHOCM E 14 Measurement Data Let REENEN 15 POO m BC WE 15 Manual Operation EEN 16 Prora UE E e 17 FOI M EO e sate ueaeucee aeenencieence neue 18 Parameter Automatic Pulse MOde cscscsscecsececescnearsnecnseeenenseneass 19 PEE e ug te lea gens nciasecuteacaetesnce sue gee ucee eau ae ncieence nceuea 20 Reen EEN Soldier er tern Tre rr rr ert 21 PUIG iere E EE 22 02 2014 v1 0en
13. ior notice Illustrations are for basic understanding and may differ from the actual design of the device Accessories from other suppliers have further safety regulations and guidelines These must also be observed 02 2014 v1 0en d UTC 1 2 Trademarks All brand names and trademarks possibly protected by third parties mentioned with in this manual are subject without restriction to the provisions of applicable trade mark laws and the ownership rights of the respective registered owners All trademarks trade names or brand names are or may be trademarks or registered trademarks of their respective owners All rights which are not expressly granted herein are reserved The absence of an explicit labeling of registered trademarks used in this manual does not conclude that a name is free of third party rights e Windows Windows XP Windows 2000 Windows Vista Windows 7 Windows 8 as well as ActiveSync are trademarks of the Microsoft Corpora tion e Acrobat and Acrobat Reader are trademarks of Adobe Systems Incorpo rated 1 3 Limitation of Liability All information and instructions in this user s manual have been compiled in accord ance with applicable standards and regulations the current state of technology as well as our knowledge and experience WOODWAY GmbH accepts no responsibility for damages resulting from Failure to observe the user s manual Unauthorized use of the PPS treadmill see oper
14. m file 02 2014 v1 0en For The Long Rum OODWAY 02 2014 v1 0en 6 3 Operation Run Protocol Info About Protocol Name Conconi Distance 37 km Maximum HA 1 min Info About Current Step Number of Step 1 Duration 3450 min Speed 6 13 km h Inclination DI Distance 380 m Acceletation 050 m s Starttime 1130 START OE A Measurements Protocols Run Protocol Fig 10 Program Sequence Program Editor The program editor for running programs is accessed through the toolbar in the main screen It is divided into a graphic display a programming section and an in put table The program steps can be sequentially entered and changed in the input table Graphic programming allows well defined speed curves and acceleration sequences which are difficult to enter into the table The entered programs can be stored and loaded again later Stored programs are available for use in the Programs file Running programs consist of Program data Program name start time and maximum pulse Program sequence data Speed acceleration running surface incline and step duration These parameters can be entered and changed in the Program Editor except start time The maximum pulse and the start time can be selected in the program se quence file before starting the program 17 Operation 18 0 3 1 EN ERR For The Long Run WOODWAY Name of Protocol Max HR l
15. mum 3 and their printing order can be selected If more curves or value tables are needed they can be printed by selecting the print function again When printing a running program the selection options limited to the representation of speed and incline with relation to time 02 2014 v1 0en W opowayv Troubleshooting 7 Troubleshooting ATTENTION With the exception of the malfunctions described in this section the treadmill and the treadmill software can only be checked and repaired by qualified personnel If necessary the WOODWAY dealer or service center is to be contacted Check that all requirements in System Requirements section on page 7 USB to Serial Converter if applicable on page 9 Interface Wire on page 10 and Set tings on page 12 are met when using the Software with your WOODWAY treadmill Possible Malfunctions Description of Malfunction Trouble Shooting Connection between PC and treadmill not Check Device Manager Control Panel for which COM port is possible used by Windows for the selected connection and set that port COM 1 4 in the control software The USB to Serial Converter was removed Check Device Manager Control Panel for which COM port is from the USB port and plugged into a used by Windows for the selected connection and set that different port port COM 1 4 in the control software The select the identical connection in the WOODWAY control software options Interface wire dama
16. ossession of the CD or connection cable please contact WOODWAY customer service We would be happy to send you the CD or the interface cable or send you the link to download the software System Requirements Before installing and using the software the following requirements must be veri fied Medically approved computer or notebook Windows 2000 XP Vista Windows 7 or Windows 8 operating system min 512 MB RAM min 50 MB free space on the hard drive monitor with min 1024 x 768 resolution CD DVD ROM drive RS 232 interface wire for computer to be connected to a free serial port or a free USB interface with RS232 to USB converter The RS232 to USB converter can also be obtained at WOODWAY Safety WOODWAY 3 Safety 3 1 Description of Warning Notices Warning notices indicate potential hazards or safety risks They are indicated in this manual by a color coded signal word panel symbol with the appropriate signal word All warning notices have the same design and the same standardized content de sign Sample of a Warning Notice Warning Text Type and Source of Danger Description of the consequences of ignoring the danger gt Measures instructions and forbidden actions to avoid the hazard gt Classification NOTE or WARNING no danger symbol No risk of injury pertinent information and warning against material damage CAUTION with danger symbol Slight possibility of inju
17. r Manufacturer ATEN Model UC 232A 4 1 1 Technical Data USB to Serial Adapter USB to Serial Converter brand ATEN model UC 232A USB specification v1 1 RS 232 connection with one DB9 plug male Plug with nuts Wire length 31cm Data rate up to 230 Kbps No own IRQ required 4 1 2 System Requirements Windows XP Vista Windows 7 Windows 8 32 64 bit Windows 98SE ME 2000 Mac OS 9 or higher Notebook medically approved with a free USB port 02 2014 v1 0en 9 Hardware 10 4 1 3 4 2 For The Long Rur WOODWAY Driver WOODWAY expressly recommends using the latest driver for the adapter Drives for common operating systems are included on the adapter CD ROM Addi tional drivers can be downloaded directly from the manufacturer s website as need ed www aten com Installing Drivers Administrator rights are needed for initial driver installation Installation under a limited user account will be terminated with an error message Interface Wire To control the treadmill via PC or laptop the serial interface of the treadmill must be connected with the computer via a so called null modem wire with two D SUB con nectors 9 pin female This interface wire must be shielded and must not exceed a length of 5 meters This wire can be obtained commercially or from WOODWAY customer service It is important to know that the market null modem wires are available with differ ent configuration
18. ry WARNING with danger symbol In a dangerous situation a serious accident is possible with the possibility of injury or death DANGER with danger symbol In the event of an accident immediate danger of death or serious injury 3 2 Safety before Use Before operating the treadmill in conjunction with the software note the safety no tices in the PPS treadmill operating instructions Familiarize yourself with the safety instructions for the connected treadmill For more information see the supplied op erating instructions ATTENTION Before using the treadmill in conjunction with the software carefully familiarize yourself with the safety instructions Manufacturers and dealers accept no liability for personal injury and or property damage resulting from lack of information 8 02 2014 v1 0en VW DODVWAN _ _ Marae 4 Hardware 4 1 USB to Serial Converter A USB to Serial Adapter allows the connection of devices with the serial interface RS 232 e g modem mouse etc to a free USB port on your PC or notebook Various models from different manufacturers are commercially available Full con formity with RS 232 specifications must be ensured when in use Not doing so can lead to communication problems between computer and treadmill The industrial grade USB to Serial Adapter from ATEN Model UC 232A can be obtained through the WOODWAY customer service Fig 1 USB to Serial Adapte
19. s depending on whether a hardware handshake and or hard ware flow control is desired A typical configuration is shown in the following table To control a WOODWAY treadmill usually only the signals GND TxD and RxD are required If a minimal null modem wire is used within the respective connect or the pins 1 4 and 6 as well as 7 and 8 should be connected see illustration Fig 2 RS 232 Interface Wire 2x D SUB 9 pin Configured 02 2014 v1 0en For The Long Run WOODWAY 02 2014 v1 0en Hardware Configuration of a typical null modem wire Pin function D SUB 9 pin Pin oy a OTR 4 DTR 5 ND 78 RIS C15 The WOODWAY treadmill control software uses the following interface parame ters e 9600 Bd baud 8 bits no parity 1 stop bit 11 Software Description WOODWAY 5 Software Description 5 1 Installation Save Data Under some circumstances the computer must be restarted after installing the treadmill control software Save all documents that you are working on before installation Close all programs before installation Insert the CD labeled treadmill control into the CD DVD drive and open Windows Explorer Open the appropriate drive and double click the WWStandardPlus exe file to start the installation process Follow the installation prompts language license information destination folder and complete the software installation Setup Sprache auswahlen e Wahlen Sie
20. the Software Notices on the Software Areas of Application The treadmill control software serves to control the treadmill and display parame ters The treadmill control software can also be used for data analysis and docu mentation The treadmill control software is not intended for medical diagnostic or medical evaluation The treadmill control software is used to control the following PPS series treadmills PPS 43 Plus PPS 43 Med PPS 43 Med i PPS 43 Ortho PPS 55 Plus PPS 55 Med PPS 55 Med PPS 55 Ortho PPS 70 Plus PPS 70 Med PPS 70 Med PPS 70 Ortho The treadmill control software can also be used with the PPS Plus LOKO PPS Med LOKO PPS Med i LOKO and PPS Ortho LOKO models The WOODWAY treadmill control software is intended for the following areas of ap plication Control and display of speed for WOODWAY treadmills without display unit WOODWAY User System or Data Monitor e Control of WOODWAY treadmills with user created programs Printing the parameters in the form of graphs or tables e Exporting the data into csv files for further processing in MS Excel or SPSS Scope of Delivery The WOODWAY treadmill control software is included on the supplied software CD delivered with the PPS treadmill For controlling via the software a RS 232 connec tion cable is required between treadmill and a medically approved computer A suit able serial interface cable is also included to the scope of delivery If you are not in p
21. ting pulse rate a lower value should be set 19 Operation Maximum Speed Minimum Speed Maximum Incline Minimum Incline 20 For The Long Rum WOODWAY This speed represents the upper control limit It can change during pulse regulation due to changes made by the operator This speed is the lower control limit It behaves similarly to the maximum speed This incline represents the upper control limit It can be changed during pulse control due to manual operation This incline is the lower control limit It behaves similarly to the maximum incline After the treadmill automatic pulse mode starts Pulse control appears on the main screen Desired HA 100 17min Maximum HA 130 1 min Self Assessment A Maximum Speed 27 00 m s Minimum Speed 0 00 m s Maximum Inclination RK Minimum Inclination 0 0 Measurements Protocols HR Control Fig 13 Pulse Control In this screen the pulse rate speed incline and load are displayed graphically The current pulse parameters appear on the right side of the screen These can be changed at any time In the button part of the screen there are keys to start or stop pulse control mode If pulse control has already been started a manual control ap pears in this location for manually adjusting the speed and incline After the start button has been pressed the treadmill automatically changes the speed and incline to reach the the predet
22. viere Ereignismodus e A DYD CD ROM Laufwerke wi Vv 2 Eingabeger te Human Interface Devices En 2 Grafikkarte IDE ATAJATAPI Controller Si IEEE 1394 Bus Hostcontroller lt Laufwerke 1 gt M use und andere Zeigeger te Modems k Monitore B Netzwerkadapter PCMCIA Adapter SB Prozessoren d SCSI und RAID Controller ep Speichervolumes d Systemgerate lt lt Tastaturen Gr USB Controller Fig 4 Interface in the Device Manager due to operating system figure in Ger man Check in advance which port Windows assigned to the COM port If the com puter is equipped with a physical serial port this is normally COM 1 If a USB to serial adapter is used on a USB port select an appropriate COM port number 1 4 in the operating system device manager Right click on the selected interface gt Properties gt Port Settings gt Ad vanced gt Select the COM port number e Ensure that Windows assigns a new COM port number to a USB to serial adapter if it was removed and a different USB port was used Further Settings Unit of measure for speed This information is needed to represent the speed in the program e Language Event mode active unit of measure for load Hardware Software Unit of Speed mem Ze kmh 2 A a Ski English C mph mi Unit of Strain Fig 5 Program Settings 13 Software Description For The Long Run 14 5 3 WOODWAY Main Scre
Download Pdf Manuals
Related Search
Related Contents
User manual ALFANET 85 Cool thermostat with fan VIESMANN REX-PEPB4ユーザーズマニュアル BlueWalker VI 650SE LCD JVC LM-170 Flat Panel Television User Manual Notice porte PARDOOR Ressort Arrière CLS-M3 Installation & Service Manual PASCO Specialty & Mfg. TD-8577 User's Manual CDX-S2000 Copyright © All rights reserved.
Failed to retrieve file