        AutoDome Roof Parapet Mount
         Contents
1.                                                                          BNC                         P105                                            lt                  J102                                        P104                                                      SS e Qe eegqgeoeegegded  e       1                                          pio                TOTr  90Td    Figure 2 4  VG4 A PSU1 or VG4 A PSU2 Power Supply Box Connected to Pipe Interface Board                                                       VG4 A PSU1 VG4 A PSU2 Pipe Interface Board  1  120 VAC 230 VAC Powerin  7 P101 Connector  2  P101 Connector 8 P107 Connector  3  Ground Connection 9 24 VAC Power In  to AutoDome   4  Transformer 10  Earth Ground  5  24 VAC Power Out 11  24 VAC Power In  to AutoDome   6  P107 Connector 12  24 VAC Power In  to Heater   13 124 VAC Power In  to Heater   14  AutoDome Power  15  Heater Power  NOTICE     Fiber Optic Models require that the Biphase control wires be routed from the Power Supply  Box P106 connector out to the Pipe Interface Board P105 connector           F 01U 250 236   1 0   2011 08 Installation Guide    Bosch Security Systems  Inc        AutoDome Roof Parapet Mount    Installing the Roof Parapet Mount en 15       2 4 2 Wiring the Power Supply Box    1     Route the high voltage 115 230 VAC lines through the conduit fitting on the left side of  the box        NOTICE   The Power Supply Box with transformer comes with a barrier that separates the high voltag
2.                           NOTICE    Fasteners are not supplied with the Roof Parapet Mount Kit since it depends on the material  to which it is attached  The material must accommodate a minimum pull out strength of 275  kg  600 Ibs   For example  19 mm  3 4 inch  minimum for plywood  Fasteners can include  bolts  studs  or lag bolts  All fasteners must be made of corrosion resistant stainless steel   with a diameter of 10 mm  3 8 inch     All bolts must fully extend through the mounting surface and be secured with a flat washer   lock washer and a nut  All studs must be anchored to concrete or welded to a steel backing  plate  Anchor bolts can be used for blind structures where there is no access to the rear        3  Apply a weatherproof sealant around each fastener hole at the mounting surface    4  Attach the Parapet Wall Bracket using at least six  6  stainless steel fasteners  three  3   on each side  the bracket has eight  8  holes   Be careful not to over tighten the  fasteners because it may strip the threads  If attaching the parapet mount to a flat roof   attach the optional LTC 9230 01 Roof Mount Plate to the roof and then attach the  Parapet Wall Bracket to the Roof Mount Plate    5  Insert the Parapet Pipe Arm into the mounting bracket until it bottoms in the bracket        F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount    Installing the Roof Parapet Mount en 19                                      
3.                          24 V to AutoDome   VA   Watts   14 AWG  2 5 mm    16 AWG  1 5 mm    18 AWG  1 0 mm   AutoDome 100  Indoor 14 7 5 248 m  813 ft  156 m  512 ft  98 m  322 ft   AutoDome 100  Outdoor 47   43 5 74 m  242 ft  46 m  152 ft  29 m  96 ft   AutoDome 600  Indoor 27 15 129 m  422 ft  81m  265 ft  51 m  167 ft   AutoDome 600  Outdoor  55 51 63 m  207 ft  40 m  130 ft  25 m  82 ft   AutoDome 700  Indoor 35 19 99 m  325 ft  62 m  205 ft  39 m  129 ft   AutoDome 700  Outdoor  60   55 58 m  190 ft  36 m  119 ft  23 m  75 ft   1  Standard heater module  Add Add 16 W if using VG4 SHTR XT kit   2  Standard heater module  The VG4 SHTR XT kit is not applicable to VG5 700 Series AutoDomes              Video and Control Cables    Using Coaxial Cable to Transmit Video and Control       CAUTION    600 Series AutoDome  If you are using coaxial cable to transmit video and data between the  AutoDome and the head end  you must use the coax cable with ferrite included in the  AutoDome packaging  You must connect the incoming coax cable  from the head end  to the  jack  female end  on the ferrite cable and connect the plug end  male connector  of the ferrite  cable to the AutoDome   s coax connector        Coaxial cable terminated with BNC connectors is the most common method for transmitting  composite video  Bilinx control data can also be sent over the same cable    Bilinx is a Bosch 2 way communication protocol that allows remote control  configuration  and  updates over a vide
4.       Data Interface Ethernet   Data Rate 10 100 Mbps  IEEE 802 3 Compliant  Full Duplex or Half Duplex Electrical Port  Full Duplex Optical Port   Fiber Type  MMF 50 125 um MMF  For 50 125 um fiber  subtract 4 dB from the  specified optical budget value  Must meet or exceed fiber standard  ITU T G 651    Fiber Type  SMF 8 10 125 um SMF  Must meet or exceed fiber standard ITU T  G 652    Maximum Distance 60 km  37 3 miles    Requirement Media converter receiver  CNFE2MC IN  at controller end of  system   Terminal Connection Duplex LC or Single SC             Control only Cables    Controlling the AutoDome via Biphase   Shielded 2 wire  half duplex  multi drop  5000 ft  cable limit     Biphase is the standard Bosch protocol used to send Pan Tilt Zoom control over 2 wire  shielded twisted pair  STP  terminated with a 100 O terminal resistor   The AutoDome has a 100 Q termination resistor between the Biphase C  and C  terminals        CAUTION   The Biphase shield must be connected to the head end only                             Cable Type STP   Shielded Twisted Pair   Distance 1524 m  5000 ft  Belden 8760 recommended  Transmission Rate 31 25 KHz   Gage 1 02 mm  18 AWG    Termination 100 Q   Terminal Connector Screw terminals   Voltage 4 Vp p                   Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08          30 en   Cable and Wire Standards    AutoDome Roof Parapet Mount       The figure below illustrates the connections necessary for Biphas
5.    AutoDome Roof Parapet Mount Alarms and Relay Connections  en 37       4    Alarms and Relay Connections                                        4 1 Alarm Inputs  The AutoDome provides seven alarm inputs  Each input can be activated by dry contact  devices such as pressure pads  passive infrared detectors  door contacts  and similar devices   The table below summarizes the size and distance wires   Wire Size Maximum Distance  AWG  mm feet meters  22 0 644  500 152 4  18 1 024   800 243 8  Table 4 1 Alarm wire guide  You wire alarms either Normally Open  N O   or Normally Closed  N C    and must program the  alarm inputs N O   the default  or N C  through the AutoDome main menu   The AutoDome incorporates two  2  types of alarms  Non supervised and Supervised  In  addition to transmitting an alarm condition  a supervised alarm also transmits a tamper  condition  Depending on how the alarm is configured  a short or a break in the alarm   s circuit  can trigger the tamper signal   4 2 Configuring Supervised Alarms  inputs 1 and 2   To configure Alarm 1 or 2  pin 5 or 6  for supervision  you must install a 2 2 K end of line  resistor in the circuit  Then  you program the alarms through the AutoDome main menu to  either Normally Open Supervised  N O S   or Normally Closed Supervised  N C S     NOTICE   Only Alarms 1 and 2  pins 5 or 6  can be configured for supervision  Once a supervised alarm  is programmed it does not need to be enabled to indicate a tamper condition   4 2 1 Co
6.   6  Remove the End Cap from the front of the arm and feed the video  control  and power  wires up through the bottom of the pipe arm and out the front end   er     Figure 2 7 Parapet Mount  1  End Cap with O ring  2  Parapet Pipe Arm  3  1 4 20 SS Cap Screw  4 Down Pipe  5  10 24 SS Pan Head Screw  7  Fold the video  control  and power wires back at the front end of the arm and route them  down and out through the Down Pipe  Then replace the End Cap   8  Wrap at least five layers of Teflon tape around the Down Pipe threads   9  Apply the supplied thread sealant to the Down Pipe threads       Make sure all surfaces are clean and dry       Apply a bead of sealant completely around the leading threads of the male fitting       Force the adhesive into the threads to thoroughly fill all voids   10  Thread the Dome Cap onto the down pipe and tighten securely  See the illustration  below   WARNING     You must thread the Dome Cap onto the Down Pipe until it is tight  Failure to do so can result    in damage  serious injury  or death           Figure 2 8 Attach Dome Cap       1  Thread Sealant or tape  2  Dome Cap                      Bosch Security Systems  Inc     Installation Guide F 01U 250 236   1 0   2011 08       20 en   Installing the Roof Parapet Mount AutoDome Roof Parapet Mount       11  Runa bead of RTV Silicon sealant around the down pipe Dome Cap interface to seal any  gaps between the down pipe and the Dome Cap    12  Proceed to Section 2 6 Wire the Pipe Interface Boa
7.   Fiber Optic kits  available for AutoDome 100 and 600 Series cameras  transmit both video and  Biphase control over an analog singlemode or multimode fiber                       Multimode   Fiber Type 50 125 um  62 5 125 um  low loss multimode glass fiber  Maximum Distance 4 km  2 5 miles    Minimum Bandwidth 20 MHz  Video   850 nm   Control   1300 nm    Requirement Bosch LTC 4629 Fiber Receiver at controller end of system  Terminal Connector ST             Singlemode       Fiber Type 9 125 um  low loss single glass fiber  Maximum Distance 69 km  43 miles     Minimum Bandwidth 20 MHz  Video   1310 nm  Control   1550 nm              Requirement Single mode fiber receiver at controller end of system       Terminal Connector ST                   F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount Cable and Wire Standards en 29       3 3 5    3 4  3 4 1    Using a Fiber Optic Ethernet Media Converter to Transmit Video and  Control   The fiber optic media converter kit  available for AutoDome 700 Series cameras  is designed  to transmit 10 100 Mbps Ethernet signals over fiber optic cable using 10 100 Mbps Small  Form factor Pluggable  SFP  modules  The SFP modules are available as multi mode fiber   MMF  or single mode fiber  SMF  models with a single SC connector or dual fiber with an LC  connector  Refer to the VG4 SFPSCKT Fiber Optic Media Converter Installation Guide        Ethernet Media Converter                   
8.   If not avoided  this will result in an electrical shock  serious bodily injury  or death           WARNING   Medium risk  Indicates a potentially hazardous situation   If not avoided  this could result in minor or moderate bodily injury           CAUTION   Low risk  Indicates a potentially hazardous situation   If not avoided  this could result in property damage or risk of damage to the unit           OBB D    NOTICE   This symbol indicates information or a company policy that relates directly or indirectly to the  safety of personnel or protection of property        1 2    Important safety instructions    Read  follow  and retain for future reference all of the following safety instructions  Heed all   warnings on the unit and in the operating instructions before operating the unit    1  Cleaning   Unplug the unit from the outlet before cleaning  Follow any instructions  provided with the unit  Generally  using a dry cloth for cleaning is sufficient but a moist   fluff free cloth or leather shammy may also be used  Do not use liquid cleaners or aerosol  cleaners    2  Water   Do not use this unit near water  for example near a bathtub  washbow l  sink   laundry basket  in a damp or wet basement  near a swimming pool  in an outdoor  installation  or in any area classified as a wet location  To reduce the risk of fire or  electrical shock  do not expose this unit to rain or moisture    3  Object and liquid entry   Never push objects of any kind into this unit through openin
9.   This chapter details how to install an AutoDome roof parapet mount  Any variations to the  installation procedures are noted    Note  You may need to purchase additional mounting accessories for roof mount applications   Refer to Section 2 1 2 Optional Mounting Accessories  page 9    The VGA ROOF MOUNT mounts are stationary mounts intended for rooftop parapet vertical  walls  They are made of light weight aluminum with a corrosion resistant finish and are used  for all Bosch AutoDome Cameras up to a rated load of 29 kg  64 Ib   These mounts can be  fitted to the inside or outside of parapet walls and can swivel for ease of positioning and for  servicing the AutoDome        Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       10 en  Installing the Roof Parapet Mount AutoDome Roof Parapet Mount       2 1 5    2 2    Tools Required       5mm Allen wrench  supplied        Small straight blade screwdrivers   2 5 mm  0 1 in       3 1 mm  1 8 in      Medium straight blade screwdriver       No  1 and No  2 Phillips screwdrivers     Socket wrench and 9 16 in  socket       Pipe Wrench       Barrel connector  if installing a fiber optic model     Pre installation Check List    1  Determine the location and distance for the power supply box based on its voltage and  current consumption  Refer to Section 3 Cable and Wire Standards  page 26 for wiring  information and distances    2  Use only UL listed liquid tight strain reliefs for conduits to the Power S
10.  THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING   RELATED FUNCTIONS OF THIS PRODUCT     Bosch notices    Video loss   Video loss is inherent to digital video recording  therefore  Bosch Security Systems cannot be  held liable for any damage that results from missing video information  To minimize the risk of  lost digital information  Bosch Security Systems recommends multiple  redundant recording  systems  and a procedure to back up all analog and digital information     Copyright  This manual is the intellectual property of Bosch Security Systems and is protected by  copyright  All rights reserved     Trademarks  All hardware and software product names used in this document are likely to be registered  trademarks and must be treated accordingly     Note    This manual has been compiled with great care and the information it contains has been  thoroughly verified  The text was complete and correct at the time of printing  The ongoing  development of the products may mean that the content of the user guide can change without  notice  Bosch Security Systems accepts no liability for damage resulting directly or indirectly  from faults  incompleteness or discrepancies between the user guide and the product  described     More information  For more information please contact the nearest Bosch Security Systems location or visit  www boschsecurity com       F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount I
11.  supply only           1  Analog AutoDome  Attach a BNC connector to the video coax cable and connect it to its  mating connector J102 on the Pipe Interface Board    2  Analog AutoDome  If using UTP for video  attach an RJ45 connector plug to the UTP  cable and connect the plug to its mating connector J101 on the Pipe Interface Board     WARNING     Do not connect the RJ45 connector unless using UTP video  This connection causes video  distortion           3  IP AutoDome  Attach an RJ45 connector plug to the Ethernet cable and connect the plug  to its mating connector J101 on the Pipe Interface Board    WARNING    Do not connect the RJ45 connector unless using UTP video or Ethernet  This connection   causes video distortion           4  Attach the control data in out wires to their respective terminals on the P105 connector  on the Pipe Interface Board  Refer to Figure 2 9  Page 20  for an illustration of these  connections    5  Connect the 24 VAC power wires to the P101 connector on the Pipe Interface Board  If  this model has a heater  connect the 24 VAC heater power wires to connector P107     CAUTION   To protect the AutoDome from damage due to cold temperatures  ensure that you connect the        gt  Bb Bb D    24 VAC heater power wires to the P101 connector        6  To connect alarm inputs and outputs  attach the supplied 6 pin Alarms In and the 4 pin  Alarms Out connector plugs with flying leads to the appropriate alarm wires  Then  connect the plugs to their mating 
12. AutoDome Roof Parapet Mount  VGA ROOF MOUNT       BOSCH    en Installation Guide       AutoDome Roof Parapet Mount Table of Contents   en 3       Table of Contents             1 Important Safety Instructions 5  1 1 Safety precautions 5  1 2 Important safety instructions 5  1 3 Important Notices 7  1 4 UL certification 7  1 5 Bosch notices 8  2 Installing the Roof Parapet Mount 9  2 1 Unpacking 9  2 1 1 Parts List 9  2 1 2 Optional Mounting Accessories 9  24 3 Optional Power Supplies 9  2 1 4 Description 9  2 15 Tools Required 10  2 2 Pre installation Check List 10  2 3 Mount Power Supply Box 11  2 3 1 Attach Cover Door 12  2 4 Route Wires and Attach Connectors 13  2 4 1 Methods for Routing Wires 13  2 4 2 Wiring the Power Supply Box 15  2 4 3 Power Supply Box Connections 16  2 5 Installing the Roof Parapet Mount 17  2 6 Wire the Pipe Interface Board 20  2 6 1 Wiring for Multiple AutoDomes 21  2 6 2 Connecting Wires to the Pipe Interface Board 22  2 7 Attach Pendant to Pipe and Tighten 24  3 Cable and Wire Standards 26  3 1 Power 26  3 2 Wire Distance Guide for Pendant 26  3 3 Video and Control Cables 26  3 3 1 Using Coaxial Cable to Transmit Video and Control 26  3 3 2 Using UTP to Transmit Video and Control 27  3 3 3 Using Ethernet to Transmit Video and Control 28  3 3 4 Using Multi mode Fiber Optic to Transmit Video and Control 28  3 3 5 Using a Fiber Optic Ethernet Media Converter to Transmit Video and Control 29  3 4 Control only Cables 29  3 4 1 Controlling the AutoDome 
13. Closed Normal   Short Tamper             F 01U 250 236   1 0   2011 08    Installation Guide    Bosch Security Systems  Inc        AutoDome Roof Parapet Mount Alarms and Relay Connections  en 39       4 3 Configuring Non supervised Alarms  inputs 1 through 7     You can configure alarms 3 through 7 as non supervised Normally Open  N O   or Normally  Closed  N C   alarms     4 3 1 Configuring a Normally Open Non supervised Alarm  1  Connect the alarm to the appropriate input  1 through 7  and ground at the AutoDome     Figure 4 3 N O    Normally Open Non supervised Connections       1  Dry Contact 3   Dome Connector   2  Alarm Inputs 1 to 7 4  Ground   2  From the AutoDome main menu select Alarm Setup gt Inputs Setup  and set Alarm Input    to N O  See the table below for contact and condition details                             AutoDome Programmed N O        Circuit Alarm Indication       Open Normal       Closed Alarm                4 3 2 Configuring a Normally Closed Non supervised Alarm  1  Connect the alarm to the appropriate input  1 through 7  and ground at the AutoDome        Figure 4 4 N C  Normally Closed Non supervised Connections       1  Dry Contact 3   Dome Connector   2  Alarm Inputs ito7  4  Ground   2  From the AutoDome main menu select Alarm Setup gt Inputs Setup  and set Alarm Input    to N C  See the table below for contact and condition details                                      AutoDome Programmed N C   Circuit Alarm Indication  Open Alarm   Closed Norm
14. Line Input Specifications                Max  Input Voltage 5 5 Vpp   Impedance 9KO   Sample Rate 8 K Hz  16 Bit  mono   Shield Bare copper braid  95  coverage          Internal gain level adjustment is available       Wire Specifications       Wire Type    Coax   recommended        Distance    10 m  33 ft        Gage    22 AWG to Biphase connector  P105 P106        Shield    Bare copper braid  95  coverage       Center conductor          Stranded bare copper             NOTICE     Separate the audio cables from the AC power lines to avoid noise           Bosch Security Systems  Inc     Installation Guide F 01U 250 236   1 0   2011 08       36 en   Cable and Wire Standards    AutoDome Roof Parapet Mount       Audio Connections                                                 1  Remove the 100 Q termination resistor from the Biphase terminals   2  Connect the audio line level source to the Biphase C  input terminal   3  Connect the audio signal ground to the Biphase C  input terminal   The following figure illustrates the connections for audio over an IP network   Figure 3 10 Connections for audio over an Ethernet network  1  C   Biphase  7 AutoDome Data In Out  2   C   Biphase  8 P105 P106 Connector  3  Earth Ground 9 Audio Out  4  RxD  5  TxD  6  Signal Ground  NOTICE     Refer to the VG5 700 Series AutoDome User Manual for configuring and using audio over an IP  Ethernet network           F 01U 250 236   1 0   2011 08    Installation Guide    Bosch Security Systems  Inc     
15. P107   24 VAC Power to Dome Dome Earth Heater Heater  Dome Plug 24 VAC 24 VAC Ground    24 VAC   24 VAC    1  Applicable to VG5 600 and 100 Series AutoDomes only              Table 2 1 Power Box Connections    2 5 Installing the Roof Parapet Mount    This section details the installation steps for the Roof Parapet Mount                 Figure 2 5 Parapet Roof Mount    1  Determine the wall location on the roof for the AutoDome and use the Parapet wall  mount bracket as a template to mark the hole locations        NOTICE  Allow enough room below the Parapet Mount Bracket to route the video  control and  alarm wires up through the Parapet arm  In certain installations you may have to lift the  Parapet arm for the AutoDome to clear the top of the wall when it is swung into position   Provide enough slack in the wires to rotate the pipe arm over the roof and back when camera  maintenance is required           Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       18 en   Installing the Roof Parapet Mount AutoDome Roof Parapet Mount       2  Prepare the mounting surface for the type of fastener by drilling holes for the mounting  anchors as required           Figure 2 6 Parapet Wall Mount Bracket and Roof Mount Plate       1  Pipearm 4  Apply sealant around each fastener hole  Parapet Wall Bracket 5  Roof Mount Plate  3  3 8 16 SS Hex Head Bolt  supplied  6  Use a minimum of six  6  fasteners  not    supplied   Eight  8  fastener holes shown        N  
16. al                   Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       40 en  Alarms and Relay Connections AutoDome Roof Parapet Mount       4 4 Alarm Outputs    The AutoDome incorporates two  2  types of alarm outputs  a dry contact relay and three  3   open collector outputs or transistor outputs     4 4 1 Configuring a Dry Contact Relay  The dry contact relay acts like an on off switch  It has a maximum voltage rating of 2A    30 DC   1  Connect the appropriate stripped wire to the AutoDome COM connector   2  Connect the appropriate stripped wire to the N O  or N C  connector  depending on your  requirement     4 4 2 Configuring an Open Collector Output  Outputs 1  2  and 3 are open collector types  These outputs must be connected to a positive  voltage between 5 and 32 V to complete the circuit  with a maximum voltage rating of 32 VDC      150 ma   1  Connect the appropriate stripped wire to the open connector  1  2  or 3  of the  transistor     2  Connect the appropriate stripped wire to the ground  GND  connector        F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc     Bosch Security Systems  Inc    850 Greenfield Road   Lancaster  PA 17601   U S A    www boschsecurity com      Bosch Security Systems  Inc   2011       
17. al  use an isolation  transformer  available separately from Bosch         CAUTION   Connecting System ground to Safety ground may result in ground loops that can disrupt the  CCTV system        1 4    UL certification    Disclaimer   Underwriter Laboratories Inc      UL     has not tested the performance or reliability of the  security or signaling aspects of this product  UL has only tested fire  shock and or casualty  hazards as outlined in UL s Standard s  for Safety for Closed Circuit Television Equipment  UL  2044  UL Certification does not cover the performance or reliability of the security or signaling  aspects of this product    UL MAKES NO REPRESENTATIONS  WARRANTIES  OR CERTIFICATIONS WHATSOEVER  REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED  FUNCTIONS OF THIS PRODUCT        Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       8    en   Important Safety Instructions AutoDome Roof Parapet Mount       1 5    Disclaimer   Underwriter Laboratories Inc      UL     has not tested the performance or reliability of the  security or signaling aspects of this product  UL has only tested fire  shock and or casualty  hazards as outlined in UL s Standard s  for Safety for Information Technology Equipment  UL  60950 1  UL Certification does not cover the performance or reliability of the security or  signaling aspects of this product    UL MAKES NO REPRESENTATIONS  WARRANTIES  OR CERTIFICATIONS WHATSOEVER  REGARDING
18. ay Output P104 AWG 26 16  3 Normally Closed  2 Common  1 Normally Open  9 Dome Power P101 AWG 18 14  3 Dome 24 VAC  2 Earth Ground  1 Dome 24 VAC  10  Heater Power P107 AWG 18 14  2 Heater 24 VAC  1 Heater 24 VAC  11  RJ45 Ethernet or UTP Video J101   Ethernet for VG5 700 Series only   12  To AutoDome       2 6 1    Wiring for Multiple AutoDomes    To wire multiple AutoDomes in a series  or    daisy chaining     you must apply a terminating  resistor to the last dome of the series  The Interface Board is supplied with a 100 Q  terminating resistor located between the Biphase terminals C  and C   pins 1 and 2  of the  P105 control connector  see item 5 in Figure 2 9 above   Remove the resistor from all but the  last AutoDome Interface Board  The maximum number of AutoDomes that can be daisy    chained is four  4    If using the RS485 protocol for control  switch the terminating resistor from the Biphase C   and C  terminals to the RxD  and TxD  terminals  pins 4 and 5  of the P105 control connector    for the last dome  refer to item 6 in Figure 2 9 above         Bosch Security Systems  Inc     Installation Guide    F 01U 250 236   1 0   2011 08          22 en   Installing the Roof Parapet Mount AutoDome Roof Parapet Mount       2 6 2 Connecting Wires to the Pipe Interface Board   The Pipe Interface Board contains all of the connectors for control  data  image  and power  wires  Follow the procedures below to make the proper connections    WARNING    Use a 24 VAC Class 2 power
19. box  Then release the bottom hinge pin from the Hinge Pin Stop to complete  attaching the Cover Door to the Power Supply Box        NOTICE   After all wiring is complete  close the cover door and tighten the two  2  captive screws on    the cover door to 10 12 N m  90 105 in  lbs  to ensure the Power Supply Box is watertight           F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 13                   2 4 Route Wires and Attach Connectors  NOTICE   AutoDome power supply boxes are sold separately  Skip the following section if your  application does not utilize one of these power supplies  VG4 A PSUO  VG4 A PSU1  or VG4 A   PSU2   Power wires must be routed to the left  front  side of the Power Supply Box through a  separate conduit  All video  control  and alarm wires must be routed through a second conduit  to the right side of the box  Refer to Section 3 Cable and Wire Standards  page 26 for methods  of transmitting video and data  and for wire specifications   WARNING   External interconnecting cables are to be installed in accordance to NEC  ANSI NFPA7O  for  US application  and Canadian Electrical Code  Part    CSA C22 1  for CAN application  and in  accordance to local country codes for all other countries   Branch circuit protection incorporating a 20 A  2 pole Listed Circuit Breaker or Branch Rated  Fuses are required as part of the building installation  A readily ac
20. cessible 2 pole disconnect  device with a contact separation of at least 3 mm must be incorporated    2 4 1 Methods for Routing Wires    There are two possible methods to route the video  control  and alarm wires       One is to route the video  control  and alarm wires through the conduit fitting on the right   front  side of the Power Supply Box and out to the AutoDome Interface Board                                                                                                  XF103             H  54321                                                                                                                                                          Figure 2 3 VG4 A PSU1 or VG4 A PSU2 Power Supply Box                   1 120 VAC 230 VAC Power In 5 Coax  UTP Video  or Ethernet Wire   Ethernet for VG5 700 Series only    2 P101 Connector 6 Control Wire   3 Ground Connection 7 24 VAC Power Out   4 Transformer 8 P107 Connector                      Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       14 en  Installing the Roof Parapet Mount    AutoDome Roof Parapet Mount            The second method is to bypass the Power Supply Box and route the video  control  and  alarm wires directly to the Interface Board  You connect only the power wires inside the    Power Supply Box                                                                                                     XF101                      XF103                H  54321               
21. connectors P103 and P102 on the Pipe Interface Board     e      PIN                               NOOO BP WNPE    2  9  o         z  H   gt   a   gt   iS   2  z   s                       OAoORWNHE                Figure 2 10 Alarm and Relay Connector Plugs       F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount    Installing the Roof Parapet Mount en 23                                                          1  4 pin Alarm Connector  2  6 pin Alarm In Connector  3  7 pin Relay Connector   P102   P103   P104   Pin  Description Pin  Description Pin  Description  1  Alarm Out 1 1  jAlarm In 3 1 Alarm Out 4 Normally Open  2  Alarm Out 2 2  Alarm In4 2  Alarm Out 4 COM  3  Alarm Out 3  3 Alarm In 5 3   Alarm Out 4 Normally Closed  4  Alarm Ground 4  Alarm In 6 4  Earth Ground  5  Alarm In 7 5  Analog Alarm 1  6  Alarm Ground 6  Analog Alarm 2  7  Ground  7  To connect supervised alarms and relays  attach the appropriate wires to their terminals  on the P104 connector on the Pipe Interface Board  see Figure 2 10  above   In addition   refer to Section 4 Alarms and Relay Connections  page 37 for more details on wiring alarms  and relays   Note  There is a slot located at the top of the Interface Board to tie the wires to the  circuit board with a cable tie   8  Insert the Pipe Interface Board into the down pipe and fasten the three  3  retaining  screws to secure the board to the Dome Cap   CAUTION     Be careful not to s
22. e  side on the left from the low voltage 24 VAC side on the right           2  Cut and trim the high voltage 115 230 VAC power and ground wires with sufficient slack  to reach their connector terminal in the box  but not so long as to be pinched by or to  obstruct closing the Cover Door    3  Attach the supplied 3 pin Power Plug to the incoming high voltage power wires in the  box  Refer to connector P101 in Table 2 1  Page 17    4  Analog AutoDome  If you are using UTP for video  route the UTP cable out to where the  AutoDome will be mounted  Refer to Section 3 Cable and Wire Standards  page 26 for fiber  optic specifications    5  IP AutoDome  Route the Ethernet cable out to where the AutoDome will be mounted   Refer to Section 3 Cable and Wire Standards  page 26 for specifications    6  Route the low power 24 VAC wires from the right side of the Power Supply Box out to  where the AutoDome will be mounted  Attach the supplied 5 pin 24 VAC Dome plug to  the wire ends inside the box  Refer to connector P107 in Table 2 1  Page 17    NOTICE     All video  control  and alarm wires either pass through the Power Supply Box or by pass it and  connect directly to the Pipe Interface Board           Bosch Security Systems  Inc     Installation Guide F 01U 250 236   1 0   2011 08       16 en  Installing the Roof Parapet Mount    AutoDome Roof Parapet Mount       2 4 3    Power Supply Box Connections    The following figure is a detailed illustration of the Roof or Pipe Mount Power Supp
23. e operation        Figure 3 2 Connections for Biphase Operation                               1  C   Biphase  7 AutoDome Data In Out  2  C   Biphase  8 Head End Biphase   3  Earth Ground 9 P105 P106 Connector  4  RxD 10 C   Biphase    5  TxD 11 C   Biphase    6  Signal Ground 12 Shield                In a daisy chain configuration  where multiple domes are connected in series  the 100 Q  resistor must be removed from all but the last dome  You can daisy chain a maximum of four   4  AutoDomes                    Figure 3 3 Connections for a Daisy Chain Configuration                                        1  C   Biphase  9 Dome 3   2  C   Biphase  10 Dome 2   3   Earth Ground 11 Dome 1   4  RxD 12 Head End Biphase  5  TxD 13 C   Biphase    6  Signal Ground 14 C    Biphase    7  Last Dome Data In Out  15 Shield   8  P105 P106 Connector               OOO       F 01U 250 236   1 0   2011 08    Installation Guide    Bosch Security Systems  Inc        AutoDome Roof Parapet Mount Cable and Wire Standards en 31       3 4 2 Controlling the AutoDome via the RS232 Protocol   3 wire  full duplex  single ended  50 ft  cable limit   RS232 is acommon  single ended communication protocol used for control  Data  transmission via 3 wires  TDX  RXD  common  is from one transmitter to one receiver at  relatively slow baud rates  up to 57 6 Kbaud  and short distances up to 50 ft     NOTICE     After making the wire connections for RS232 operation  reposition the slide switch located on  the CPU Mod
24. feature cable compensation or    Pre Comp     which extends the normal  range of control from the head end     WARNING   Do not connect the RJ45 connector unless using UTP video              Cable Compensation       Maximum Distance                   Cable Type Pre comp OFF Pre comp ON  CAT5 UTP 229 m  750 ft  450 m  1500 ft   Terminal Connector RJ45   Requirement Coax to UTP Converter                The following figure illustrates the connections necessary to transmit video and control over a  UTP cable     1     amp  2                         Figure 3 1 Video and Control over UTP       1  Head End Video  3  Pins  2  Coax 4  AutoDome                            Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08          28 en  Cable and Wire Standards AutoDome Roof Parapet Mount       3 3 3 Using Ethernet to Transmit Video and Control  CAUTION   Ethernet connections must be made to non exposed  indoor  networks only           The AutoDome VG5 700 series connects to a 10 Base T 100 Base TX network either directly or  via a switch  Both video and control are transmitted over a standard TCP IP network using the  built in Web server                                Cable Type CAT 5E or CAT 6 Ethernet  Maximum Distance 100 m  328 ft   Bandwidth 10 Base T 100 Base TX  Terminal Connector RJ45  Female   WARNING     Do not connect a coaxial cable while the RJ45 Ethernet cable is connected        3 3 4 Using Multi mode Fiber Optic to Transmit Video and Control
25. gs  as they may touch dangerous voltage points or short out parts that could result in a fire  or electrical shock  Never spill liquid of any kind on the unit  Do not place objects filled  with liquids  such as vases or cups  on the unit    4  Power cord and plug protection   Protect the plug and power cord from foot traffic   being pinched by items placed upon or against them at electrical outlets  and its exit  from the unit  For units intended to operate with 230 VAC  50 Hz  the input and output  power cord must comply with the latest versions of IEC Publication 227 or IEC Publication  245    5  Power disconnect   Units have power supplied to the unit whenever the power cord is  inserted into the power source  The power cord plug is the main power disconnect  device for switching off the voltage for all units        Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       6 en   Important Safety Instructions AutoDome Roof Parapet Mount       10     11     12     Power sources   Operate the unit only from the type of power source indicated on the  label  Before proceeding  be sure to disconnect the power from the cable to be installed  into the unit         For battery powered units  refer to the operating instructions        For external power supplied units  use only the recommended or approved power  supplies      For limited power source units  this power source must comply with EN60950   Substitutions may damage the unit or cause fire or shoc
26. ion of service or repairs   to the unit to ensure proper operating condition    Installation   Install in accordance with the manufacturer s instructions and in   accordance with applicable local codes    Attachments  changes or modifications   Only use attachments accessories specified by   the manufacturer  Any change or modification of the equipment  not expressly approved   by Bosch  could void the warranty or  in the case of an authorization agreement  authority  to operate the equipment        F 01U 250 236   1 0   2011 08    Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount Important Safety Instructions   en 7       1 3    Important Notices    U S A  models only   Section 810 of the National Electrical Code  ANSI NFPA No 70  provides  information regarding proper grounding of the mount and supporting structure  grounding of  the coax to a discharge unit  size of grounding conductors  location of discharge unit   connection to grounding electrodes  and requirements for the grounding electrode        Disposal   Your Bosch product was developed and manufactured with high   quality material and components that can be recycled and reused  This symbol  means that electronic and electrical appliances  which have reached the end of  their working life  must be collected and disposed of separately from household  waste material  Separate collecting systems are usually in place for disused  electronic and electrical products  Please dispose of the
27. k      For 24 VAC units  voltage applied to the unit s power input should not exceed  10    or 28 VAC  User supplied wiring must comply with local electrical codes  Class 2  power levels   Do not ground the supply at the terminals or at the unit s power  supply terminals        If unsure of the type of power supply to use  contact your dealer or local power  company    Servicing   Do not attempt to service this unit yourself  Opening or removing covers may   expose you to dangerous voltage or other hazards  Refer all servicing to qualified service   personnel    Damage requiring service   Unplug the unit from the main AC power source and refer   servicing to qualified service personnel when any damage to the equipment has   occurred  such as        the power supply cord or plug is damaged      exposure to moisture  water  and or inclement weather  rain  snow  etc          liquid has been spilled in or on the equipment        an object has fallen into the unit         unit has been dropped or the unit cabinet is damaged      unit exhibits a distinct change in performance        unit does not operate normally when the user correctly follows the operating  instructions    Replacement parts   Be sure the service technician uses replacement parts specified by   the manufacturer  or that have the same characteristics as the original parts    Unauthorized substitutions may cause fire  electrical shock  or other hazards    Safety check   Safety checks should be performed upon complet
28. ly Box   which includes the fuse specifications                                   G                                                                                                                                2 se o  los o Fels  Ho     s  a  0  N 23 op  o o  1  Ground Screw 5  Power In  2  Transformer  115 230 VAC Modes   6  In Out  1 2 in   15 mm  NPS Fitting  3  In Out to Dome 7  Power In  3 4 in   20 mm  NPS Fitting  4  24 VAC to Dome Interface Board 8  Control Data and Video In Out  3 4 in   20 mm   NPS Fitting  WARNING     Fuse replacement by qualified service personnel only  Replace with same type fuse                                Fuse Specifications  Volts XF101 Mains   XF102 Camera   XF103 Heater  24 V T5 0A T2 0A T3 15A  115V T1 6A T2 0A T3 15A  230 V T 0 8A T2 0A T3 15A                F 01U 250 236   1 0   2011 08    Installation Guide    Bosch Security Systems  Inc        AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 17       The following table lists the Power Supply Box connectors                                               No  Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin5 Pin6  Ground Grounding Screw   P101   115 230 VAC or 24   Line NC Neutral  VAC Power In   P105    Control to Dome C  C  Earth RXD     TXD     Signal   Fiber Optic  Biphase    Biphase    Ground    RS 232 485     RS 232 485    Ground  Model    P106    Control In Out C  C  Earth RXD     TXD     Signal   Optional   Biphase    Biphase    Ground    RS 232 485   RS 232 485  Ground   
29. n the location of the  AutoDome and the application        CAUTION   Select a rigid mounting location to prevent excessive vibration to the AutoDome camera           F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount Installing the Roof Parapet Mount en 11       2 3    Mount Power Supply Box       NOTICE    AutoDome power supply boxes are sold separately  Skip the following section if your  application does not utilize one of these power supplies  VG4 A PSUO  VG4 A PSU1  or VG4 A   PSU2        Before mounting the Power Supply Box decide if you will be wiring the box through the holes  in the bottom or back of the box  If wiring the box through the back  move the two  2  seal  plugs to the bottom holes before mounting    Refer to Section 2 1 3 Optional Power Supplies  page 9  for a list of compatible power supply  boxes        NOTICE   Use 3 4 inch NPS  20 mm  fittings for the holes on the bottom and back of the box  Use 1 2   inch NPS  15 mm  fittings for the side holes           Figure 2 1 Wall Mount Power Supply with Optional Trim Skirt   1  Use the wall mount template supplied in the packaging box to locate the four  4   mounting holes for the Power Supply Box    2  Drill four  4  holes for the mounting anchors  If installing outdoors  apply a weatherproof  sealant around each hole at the mounting surface    3  Place the Power Supply Box into the optional Trim Skirt    4  Secure the Power Supply Box to the wall u
30. nd on the green  RxD  wire enough to  be able to connect these wires back into the P106 connector   6  Connect the blue  ground  wire to the C  pin on the P106 connector   7  Connect the green  RxD  wire to the C  pin on the P106 connector     E J   ab  gt  24VAC SEAN  la b LL        00  eh x   ii N  op 10  2101  paR    ED  8  24V HAE 24   O ED d         RF  O  Figure 3 8 Detail of P106 Connections  1 Green RxD wire connected to C   2 Blue Ground wire connected to C   8  Connect the fiber optic cable from the AutoDome to the LTC 4629   9  Close the door to the power supply unit        F 01U 250 236   1 0   2011 08    Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount    Cable and Wire Standards  en 35       10  Ensure that the VG5 AutoDome is set to receive RS232 commands       Remove the bubble from the VG5 AutoDome housing     Locate the protocol switch on the CPU board       Ensure that the protocol switch is in the left position for RS232 operation        Figure 3 9 Position of CPU Switch for RS232 Operation       Switch Location       LEDs       Move Switch to the left for RS232 Operation       BA  OO  N  e          CPU Module          11  Return the bubble to the AutoDome housing   12  Return power to the power supply box     3 6 Audio Cables    The VG5 700 Series AutoDome is capable of receiving line input audio signals and transmitting  it over a network  The audio signal is transmitted one way and in sync with the video signals   Audio 
31. nfiguring a Normally Open Supervised Alarm    1  Install a 2 2 K end of line resistor in the alarm circuit   2  Connect the alarm wires to input 1 or 2  pin 5 or 6  and to the ground  pin 7  at the  AutoDome        Figure 4 1 N O S   Normally Open Supervised Connections       1  Dry Contact 3   Dome Connector  2  Alarm 1 or 2 only  PinS5or6   4  Ground  Pin 7                             Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       38  en  Alarms and Relay Connections    AutoDome Roof Parapet Mount       3  From the AutoDome main menu  select Alarms Setup gt Inputs Setup  and set the Alarm  Input   to N O S  See the table below for contact and condition details                                AutoDome Programmed N O S   Contact Alarm Condition  Open Normal  Closed Alarm  Cut or brake Tamper  4 2 2 Configuring a Normally Closed Supervised Alarm    1  Install a 2 2 K end of line resistor in the alarm circuit   2  Connect the alarm wires to input 1 or 2  pin 5 or 6  and to the ground  pin 7  at the  AutoDome        Figure 4 2 N C S    Normally Closed Supervised Connections       1  Dry Contact    3    Dome Connector             2   Alarm 1 or 2 only  Pin 5 or 6        4       Ground  Pin 7           3  From the AutoDome main menu select Alarm Setup gt Inputs Setup  and set Alarm Input      to N C S  See the table below for contact and condition details                          AutoDome Programmed N C S   Contact Alarm Condition  Open Alarm   
32. nstalling the Roof Parapet Mount   en 9       2    2 1    2 1 1    2 1 2    2 1 3    2 1 4    Installing the Roof Parapet Mount    Unpacking   This equipment should be unpacked and handled with care  If an item appears to have been  damaged in shipment  notify the shipper immediately    Verify that all the parts listed in the product s Parts List below are included  If any items are  missing  notify your Bosch Security Systems Sales or Customer Service Representative    The original packing carton is the safest container in which to transport the unit and must be  used if returning the unit for service  Save it for possible future use     Parts List  The following table lists the parts included with this mounting package        Part Numbers  Parapet  Roof  Mount VGA ROOF MOUNT                   Optional Mounting Accessories  The following table lists the optional parts you may need for attaching a Pendant Arm to a roof  parapet mount              Mounting Options Part Numbers  Flat Roof Mount Adapter LTC 9230 01  Plpe Mount VG4 A 9543                Optional Power Supplies  The roof parapet mounts do not come with an attached power supply  The following table lists  the optional power supplies that are compatible with VG5 Series AutoDomes                             Mounting Options Part Numbers  24 VAC  no transformer   NEMA rated with cover VG4 A PSUO  120 VAC transformer  NEMA rated with cover VG4 A PSU1  230 VAC transformer  NEMA rated with cover VG4 A PSU2  Description  
33. o coax cable  Bilinx is available on all VG5 100 and 600 Series AutoDomes   VG5 Series AutoDomes feature cable compensation or    Pre Comp     which extends the range  of video from the head end        F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount Cable and Wire Standards en 27                                           Cable Compensation   Maximum Distances   Video Only Bilinx Control  Cable Type Pre comp OFF Pre comp ON Pre comp ON or OFF  RG 59 U 300 m  1000 ft  600 m  2000 ft  300 m  1000 ft   RG 6 U 450 m  1500 ft  900 m  3000 ft  450 m  1500 ft   RG 11 U 600 m  2000 ft  1200 m  4000 ft  600 m  2000 ft   Size O D  between 4 6 mm  0 181 in   and 7 9 mm  0 312 in    Shield Copper braid  95   Central Conductor Standard copper center  Terminal Connector BNC                WARNING   Cable compensation  Pre Comp  does not extend the range of Bilinx control  Pre Comp is not  available with VG5 700 Series AutoDomes        3 3 2 Using UTP to Transmit Video and Control  Unshielded twisted pair  UTP  cable terminated with RJ45 male connectors are used to  transmit composite video using pins 1    and 2     Typically  a Coax to UTP cable converter is  required at the head end of the system   Bilinx control data can also be sent over the same two video wires  1  amp  2   Bilinx is a Bosch 2   way communication protocol that allows remote control  configuration and updates over a  passive UTP cable   VG5 Series AutoDomes 
34. rd  page 20    NOTICE    Use a guy wire to aid in stabilizing the Parapet Arm  Replace the 1 4 inch cap screw with a   threaded 1 4 inch stainless steel eye bolt  not supplied   Loop the guy wire through the eye   bolt and attach both ends to anchor spots on the roof  Refer to Figure 2 7  Page 19           2 6 Wire the Pipe Interface Board    This section provides instructions for connecting wires and cables to the Pipe Interface  Board  as illustrated below  Refer to Section 3 Cable and Wire Standards  page 26 for cable and  wiring recommendations and specifications               HHH    P105                         J102  HE    P104    A P  Nea We ed eae                                                             Pia N fale age ge    QDOOO              Figure 2 9 Pipe Interface Board Connections       F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount    Installing the Roof Parapet Mount en 21                                                                                                       Ref   Description Connector  Wire Gauge  Pin  Description  1 Pipe Interface Module  2 Video Coax In J102  3 6 pin Connector Alarms In  3 7  P103  4 4 pin Connector Alarms Out  1 3   P102  5 100    Resistor P105  6 Data In Out P105 AWG 26 16  1 Biphase  C    2 Biphase  C    3 Earth Ground  4 RxD    5 TxD    6 Signal Ground  7 Alarms In  EOLR Supervised  1 2   P104 AWG 26 16  7 Ground  6 Alarm 2  5 Alarm 1  4 Earth Ground  8 Rel
35. se units at an  environmentally compatible recycling facility  per European Directive 2002 96 EC                Environmental statement   Bosch has a strong commitment towards the environment  This  unit has been designed to respect the environment as much as possible    Power lines  An outdoor system should not be located in the vicinity of overhead power lines   electrical lights  or power circuits  or where it may contact such power lines or circuits  When  installing an outdoor system  extreme care should be taken to keep from touching power lines  or circuits  as this contact may be fatal    U S A  models only   refer to the National Electrical Code Article 820 regarding installation of  CATV systems    SELV   All the input output ports are Safety Extra Low Voltage  SELV  circuits  SELV circuits  should only be connected to other SELV circuits    Because the ISDN circuits are treated like telephone network voltage  avoid connecting the  SELV circuit to the Telephone Network Voltage  TNV  circuits    System ground Safety ground    System  video  ground is indicated by the symbol        Safety  power  ground is indicated by the symbol      The system ground is only used to comply with safety standards or installation practices in  certain countries  Bosch does not recommend connecting system ground to safety ground  unless it is explicitly required  However  if the system ground and safety ground are  connected and grounding loops are causing interference in the video sign
36. sing four  4  corrosion resistant stainless steel  studs  not included         NOTICE   A stud diameter of 6 4 mm  1 4 in   or 8 mm  5 16 in    able to withstand a 120 kg  265 Ib   pull out force is recommended        5  Attach the 3 4 in   20 mm  watertight pipe fittings  not supplied  to the holes of the  Power Supply Box through which you will run the power  video  and control data wires        Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       12 en   Installing the Roof Parapet Mount AutoDome Roof Parapet Mount       2 3 1 Attach Cover Door  1  Compress the bottom hinge pin by pushing the pin lever down and then rotate it behind    the Hinge Pin Stop  The power box Cover Door provides a Hinge Pin Stop to hold the  bottom hinge open while attaching the door                                         Figure 2 2 Align Cover Door Hinge to Power Box       Power Supply Box  5  Hold Hinge Pin Open  Cover Door 6  Open Position  Align Top Hinge 7  Hinge Pin Stop  Align Bottom Hinge  2  Open the top hinge by pushing its pin lever outward and holding it open    Note  Both Hinge Pins must be fully compressed to open  unlock  the female hinges of    the Cover Door before proceeding to the next step   3  While holding the top hinge pin open  position the Cover Door to the Power Supply Box                         AJOJ NM  eB          and align its hinges   4  When the hinges are aligned  release the top hinge pin to engage its mating hinge on the    power 
37. t Installing the Roof Parapet Mount en 25          CAUTION   If you feel any resistance when rotating the dome housing or when engaging the connector   stop immediately and start over        5  Hold the housing firmly in position and alternately tighten the two  2  5 mm Allen head  mounting screws from above to a torque value of 10 12 N m  90 105 in  lbs     CAUTION    You must tighten the two mounting screws to a minimum torque of 10 12 N m  90 105 in  lbs    to ensure a proper seal between the arm and the housing           6  Rotate the arm to swing the AutoDome out from the roof and into position    7  Tighten the three  3  10 mm  3 8 inch  stainless steel hex bolts on the bracket to lock  the Parapet Arm in position  Refer to Figure 2 12  Page 24  for an illustration    CAUTION    Do not over tighten the bolts  The maximum torque is 34 N m  25 ft lb               Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       26 en   Cable and Wire Standards AutoDome Roof Parapet Mount       3    Cable and Wire Standards       CAUTION     Installation should only be performed by qualified service personnel in accordance with the  National Electrical Code or applicable local codes           CAUTION   All wires for installation applications must be routed through a grounded conduit        3 1    3 2    3 3  3 3 1    Power       115 230 VAC    Copper Wire To comply with local codes                    Wire Distance Guide for Pendant                        
38. th an RS232 RS422 Controller    An AutoDome with a fiber optic module is prewired to operate with Biphase signals only  This  section describes the procedures necessary to control a VG5 series AutoDome fitted with a  fiber optic kit using an RS232 controller or a Pelco   RS422 controller    To control a VG5 Series Autodome from an RS232 or from a Pelco RS422 controller you must  run control wires from the controller to an LTC 4629 head end fiber optic module        Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       34 en  Cable and Wire Standards AutoDome Roof Parapet Mount       3 5 1 Connecting to an LTC 4629 Head End Data Video Transceiver    1     Connect the RS232 cable  TxD from the controller  to the RS232 RxD port  pin 1  of the  LTC 4629                                                                                                                                                                                          2  Connect the ground wire of the controller to Pin 2 on the LTC 4629   3 5 2 Configuring the VG5 AutoDome  1  Disconnect the power to the VG4 power supply unit  then open the unit   2  Remove the green Serial Communications wire from the P106 connector   3  Remove the 100 Q resistor across the C  and C  pins   4  Cut the five wires from the green Serial Communications wire mating connector   Ensure that the insulation covers each wire to avoid wires from touching   5  Cut back the insulation on the blue  ground  wire a
39. the slide switch on the main board to  the camera head is positioned toward the LEDs  default            CAUTION    Bosch recommends that multiple RS485 connections be arranged as a connected series of  point to point  multi dropped  nodes  as a line or as a bus  It is not recommended to arrange  RS485 connections as a Star  ring  or as a multiple connected network  Star and ring  topologies may cause signal reflections or excessively low or high termination impedance                          Wire Type 2 wire shielded twisted pair  Distance 1219 m  4000 ft    Maximum Baud Rate 57 6 kb   Gage 0 511 mm  24 AWG    Wire Impedance 120 W   Slide Switch Toward LEDs  factory default                 F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc           AutoDome Roof Parapet Mount Cable and Wire Standards en 33       The following figure illustrates the connections for RS485 connections           Figure 3 6 Connections for RS485 Operations                      1  C   Biphase  T AutoDome Data In Out  2   C   Biphase  8 P105 P106 Connector  3 Earth Ground 9 Head End RS485   4 RxD 10 Data     5 TxD 11 Data     6  Signal Ground 12 Ground                         SS       Figure 3 7 Position of CPU Switch for RS485 Operation  camera module not shown for clarity        Switch Location  LEDs   RS485   CPU Module    Note  To access the CPU switch you must remove the bubble from the pendant housing              AJOJ NM  eR                3 5 Fiber Optic Module wi
40. trip the threads when tightening the Pipe Interface Board retaining screws                Daa meas    i       Pe  e    Figure 2 11 Pipe Interface Board to Dome Cap Assembly       1  Interface Board  2  Retaining Screws  3   3  Pendant Mounting Screws  2                          Bosch Security Systems  Inc     Installation Guide    F 01U 250 236   1 0   2011 08          24 en   Installing the Roof Parapet Mount AutoDome Roof Parapet Mount       2 7 Attach Pendant to Pipe and Tighten    1  Before attaching the Pendant  visually inspect the Pendant dome and the Interface Board  connectors for any blocked pin holes and bent pins    2  Tilt the Pendant enough to place its mounting hook on top of the its housing  over the  recessed hinge pin of the Dome Cap                             Figure 2 12 Pendant to Roof   Pipe Mount Attachment             1  Tilt Dome  2   Hook and drop  2a  Dome Cap       2b  Recessed Hinge Pin   2c  Dome Connector   3    Rotate down to engage dome connector   4   Tighten the two  2  mounting screws to a minimum torque of 10 12 N m    90 105 in  lbs    3  Drop the Pendant down slightly to engage the dome hook and hinge pin of the Dome  Cap  allowing the dome to rotate around the hinge pin    4  Rotate the dome housing down to a vertical position and gently push upward to engage  the connector on top of the dome housing                             F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Moun
41. ule to the camera head inward and away from the LEDs                             Wire Type 3 wire  TXD  RXD  common   Distance 15 m  50 ft    Maximum Baud Rate   57 6 Kb   Voltage  15V   Termination 100 Q   Slide Switch Away from LEDs  factory default                       Figure 3 4 Connections for RS232 Operation                         1  C   Biphase  7 AutoDome Data In Out  2  C   Biphase  8 P105 P106 Connector  3  Earth Ground 9 Head End RS232   4  RxD 10 TxD   5  TxD 11 RxD   6  Signal Ground 12 Ground                      Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       32 en   Cable and Wire Standards AutoDome Roof Parapet Mount       3 4 3       Figure 3 5 Position of CPU Switch for RS232 Operation  camera module not shown for clarity        Switch Location       LEDs       RS232  CPU Module       AJ OO  MD  e                Note  To access the CPU switch you must remove the bubble from the pendant housing     Controlling the AutoDome via the RS485 Protocol   2 wire  shielded   half duplex  differential  multi drop  32 nodes   4000 ft cable limit    RS485 is capable of controlling a true multi drop network and is specified for up to 32 drivers  and 32 receivers on a single 2 wire bus  The AutoDome uses the 2 wire mode  although RS485  can be connected in a 2  or 4 wire mode        NOTICE    The wire shield must be tied to signal at both ends  if 2 wire twisted pair is used  After  connecting the wires for RS485 operation  make sure 
42. upply Box to  ensure that water cannot enter the box  You must use water tight conduits and fittings to  meet NEMA 4 standards        NOTICE   Power and I O cabling must be routed separately inside different permanently earthed metal  conduits        3  Install all rough wiring including  power  control  video coax  alarms I O  relay I O  and  fiber optic cabling  Refer to Section 3 Cable and Wire Standards  page 26 for video and  control protocol methods    4  Analog AutoDome  If you plan to use the RS232 or RS485 protocol to control the  AutoDome  refer to Section 3 4 2 Controlling the AutoDome via the RS232 Protocol   page 31  or Section 3 4 3 Controlling the AutoDome via the RS485 Protocol  page 32  for  instructions on configuring the AutoDome to accept these protocols        WARNING    External interconnecting cables are to be installed in accordance to NEC  ANSI NFPA7O  for   US application  and Canadian Electrical Code  Part    CSA C22 1  for CAN application  and in  accordance to local country codes for all other countries    Branch circuit protection incorporating a 20 A  2 pole Listed Circuit Breaker or Branch Rated  Fuses are required as part of the building installation  A readily accessible 2 pole disconnect  device with a contact separation of at least 3 mm must be incorporated        5  Choose the appropriate VG5 AutoDome model  indoor or outdoor  for the environment in  which it will be used    6  Purchase the appropriate mounting hardware to use  depending o
43. via Biphase 29  3 4 2 Controlling the AutoDome via the RS232 Protocol 31  3 4 3 Controlling the AutoDome via the RS485 Protocol 32  3 5 Fiber Optic Module with an RS232 RS422 Controller 33  3 5 1 Connecting to an LTC 4629 Head End Data Video Transceiver 34  3 5 2 Configuring the VG5 AutoDome 34  3 6 Audio Cables 35       Bosch Security Systems  Inc  Installation Guide F 01U 250 236   1 0   2011 08       4 en   Table of Contents    AutoDome Roof Parapet Mount             4 Alarms and Relay Connections 37  4 1 Alarm Inputs 37  4 2 Configuring Supervised Alarms  inputs 1 and 2  37  4 2 1 Configuring a Normally Open Supervised Alarm 37  4 2 2 Configuring a Normally Closed Supervised Alarm 38  4 3 Configuring Non supervised Alarms  inputs 1 through 7  39  4 3 1 Configuring a Normally Open Non supervised Alarm 39  4 3 2 Configuring a Normally Closed Non supervised Alarm 39  4 4 Alarm Outputs 40  4 4 1 Configuring a Dry Contact Relay 40  4 4 2 Configuring an Open Collector Output 40  F 01U 250 236   1 0   2011 08 Installation Guide Bosch Security Systems  Inc        AutoDome Roof Parapet Mount Important Safety Instructions   en 5       1    1 1    Important Safety Instructions    Read  follow  and retain all of the following safety instructions  Heed all warnings on the unit  and in the operating instructions before operation     Safety precautions       DANGER    High risk  This symbol indicates an imminently hazardous situation such as    Dangerous  Voltage    inside the product  
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
"user manual"  BENDIX BW2611 User's Manual  Guide to the MVI69-DFCM User Manual  Descarga - NEC Display Solutions Europe  PSEE-98MHD-N  Zotac ZBox ID15  S E R V IC IO - Portal de Servicio Koblenz  WaxVac manual_fran  Operating Instructions Mode d'emploi Manual de  Jubula Installation Manual    Copyright © All rights reserved. 