1. lt D Z m gt rm Pressure 200 psi Valve 303 stainless steel with perofluroelestomer seals 3 port 1 8 inch NTP with 1 4 inch OD SWAGELOK fittings for stainless steel tubing phone 508 429 6809 fax 508 893 0160 e mail INfo kdscientific com kd Scientific web WWW kdscientific com Valve Box User s Manual Publication 5617 011 Rev B Appendices 8 APPENDIX A MAINTENANCE Maintenance Valve boxes require no special maintenance other than keeping them clean by avoiding accidental spills of pumped material To clean the exterior surfaces use a lint free cloth to remove loose dust For more efficient cleaning use a soft cloth dampened not soaked with water an ageuous solution of 7596 isopropyl alcohol or a mild detergent a Y n APPENDIX B PUMP TO VALVE BOX CONNECTIONS Y D New Legacy New p Valve Box Valve Box Valve Box NE 15 Finto 9 Pin to 15 Pin to 1S Pin 15 Pin 9 Pin Cable Cable Cable Legato Legato KDS 200 Pump Pump Pump phone 508 429 6809 fax 508 893 0160 e mail INfo kdscientific com kd Scientific web WWW kdscientific com Valve Box User s Manual Publication 5617 011 Rev B a n i P4 v2 lt D Z m gt a kd Scientific Appendices 9 APPENDIX C ORDERING INFORMATION Standard Version Description Dual Syringe Auto Fill Valve Box Low Pressure 788333 Auto Fill Valve Box Medium Pressure 788336 A
2. Valve Box USER S MANUAL Publication 5617 011 Rev B ww w kdscientific com e 0 e kc S ciontiri MET email Info kdscientific com Table of Contents 2 Table of Contents SUBJECT PAGE NO General Information re x reader tax n Rea uGa Ru ig wt e Vat aua Eg v e E RA 3 Mantal eiectum 9 I WOT E NN RET D Warranty and Repair Information aassasxezesiuistunspi ur nelintuuinsaap iut ater t text buts etriraasa amant 4 MAUS MEE uen 4 c Repair Facilities and Parts meer 4 dA SIME PT 4 TI JJ Prodiit Overveen aE E 6 Y Operating WS CO Segarra se ainnean EEEN Ee EEEIEE AE 6 lt PONOT O SC OI E E A E TA EEO 6 Valve BOX FOW Br Ic 6 nm Valve and Tubing Information 2 ccc ececcccccc cece ceeeeeeeeee mne nnne 7 Ua ADDOBUICBS cu eidem sia Ue FHURqU A SIN ONEMERUDNERSINU MM E Fata DxEENMMU COPI RUN aU DNS EUN SERAIS UE 8 Appendix A Maintenance uuosacisteptoe ti Iren Pre RPPAIn PEN obpIR M TH UIN Or bL emEUP EAM LEN etos I MI DRpbE 8 Appendix B Pump to Valve Box Connections ccccccccccecceeeceeeeeeeeeeee essen eeeaneeeeeenns 9 Appendix C Ordering Information sssssssssse menm 9 phone 508 429 6809 fax 508 893 0160 e mail info kdscientific com kd Scientific web WWW kdscientific com Valve Box User s Manual Publication 5617 011 Rev B Table of Contents 3 General Information Manual Description This manual is designed to provide all information required to connect the valve
3. box to your syringe pump and fluidic system SAFETY INFORMATION Please read the following safety precautions to ensure proper use of your valve box If the equipment is used in a am manner not specified the protection provided by the equipment may be impaired Y EL Io Prevent Hazard or Injury J USE PROPER POWER SUPPLY 02 The valve box is supplied with an approved power supply and line cord To maintain the safety integrity of the device use only the following power supplies that was shipped with the device gt USE PROPER LINE CORD Z Use only the specified line cord for this product and make sure line cord is certified for country of use The operating voltage range for the valve boxes is 12 or 24 VDC see spec page The universal power supply operating voltage E range is 100 240 VAC 50 60 Hz 115 VAC and 230 VAC versions differ only with the line cord supplied Ua GROUND THE PRODUCT This product is grounded through the grounding conductor of the power cord To avoid electric shock the grounding conductor must be connected to earth ground Before making any connections to the input or output terminals of the product ensure that the product is properly grounded MAKE PROPER CONNECTIONS Make sure all connections are made properly and securely Any signal wire connections to the unit must be no longer than 3 meters OBSERVE ALL TERMINAL RATINGS Review the operating manual to learn the ratings on all connections AVOID EXPOSED CIRCUITRY Do not
4. cated on the rear panel CAUTION FOR RESEARCH USE ONLY NOT FOR CLINICAL USE ON PATIENTS phone 508 429 6809 fax 508 893 0160 e mail INfo kdscientific com web WWW kdscientific com Valve Box User s Manual Publication 5617 011 Rev B Product Overview Product Overview POWER Power green LED ACTUATION Valve Actuated green LED uu Fault Indicator red LED example shorted coil or excess current a n T p o lt D Z m gt rm 1 0 Connector Valve In Main Switch RoHS Compani Mic Fi rh ni 2 lt VIH lt 30 v 1 0 lt VIL lt 1 2v DC Power Input 1 L The input connection is optically isolated KD Scientific syringe pumps default is set such that the valve is actuated when pump is withdrawing See pump user s manual for additional info MAT To reduce heat generation after activation the v current drops to 1 3 its value to hold phone 508 429 6809 fax 508 893 0160 e mail info kdscientific com kd Scientific web WWW kdscientific com Valve Box User s Manual Publication 5617 011 Rev B Product Overview OPERATING INSTRUCTIONS POWER CONNECTIONS 1 Plug the power cord in The Valve box has a DC power input connector on the rear of the unit The operating range for the Valve box is 12 or 24 Vdc 2 Turn on the main power switch 3 Connect to valve box to pump See Appendix B for connection details Valve Box Flow Diagrams Auto Fill Va
5. lve Boxes single valve commonly used to reload syringe once it is empty or partially empty Low Pressure Medium Pressure High Pressure Auto Fill Auto Fill Auto Fill Refill Syri nge y Hnc i x C r4 aw El a 72 u ie V2 lt gt Pa m gt rm Continuous Delivery Valve Boxes dual mounted valves commonly used with a Legato 200 Push Pull Low Pressure Medium Pressure High Pressure Continuous Continuous Continuous 4 syringe Pear Syringe Refill Infuse Syringe 1 tenth Syringa 2 Fr _ a Reservoir Reservoir For 2 discrete flow streams make connections X to both valves as done in the auto fill set up phone 508 429 6809 fax 508 893 0160 e mail info kdscientific com kd Scientific web WWW kdscientific com Valve Box User s Manual Publication 5617 011 Rev B Product Overview VALVE AND TUBING INFORMATION Low Pressure Valve Boxes Pressure 25 psi Valve pinch supplied with C flex tubing 1 16 ID x 1 8 OD This tubing can be easily replaced Other types UIL of tubing such as silicone will work as long as the durometer of the tube is 45 shore A Medium Pressure Valve Boxes Pressure 100 psi Valve Teflon for all wetted parts 3 port 1 4 28 with 1 16 OD tube fittings for plastic tubing The fittings can be replaced with barb or luer connections if needed High Pressure Valve Boxes a n T p v2
6. ntact us for more Information phone 508 429 6809 fax 508 893 0160 e mail info kdscientific com web WWW kd SC e ntifi c com Valve Box User s Manual Publication 5617 011 Rev B
7. touch any electronic circuitry inside of the product DO NOT OPERATE WITH SUSPECTED FAILURES If damage is suspected on or to the product do not operate the product Contact qualified service personnel to perform inspection ORIENT THE EQUIPMENT PROPERLY Do not orient the equipment so that it is difficult to operate the disconnection device PLACE PRODUCT IN PROPER ENVIRONMENT Review the operating manual for guidelines for proper operating environments OBSERVE ALL WARNING LABELS ON PRODUCT Read all labels on product to ensure proper usage CAUTION Protective Refer to Manual Ground Terminal phone 508 429 6809 fax 508 893 0160 e mail INfo kdscientific com kd Scientific web WWW kdscientific com Valve Box User s Manual Publication 5617 011 Rev B am n m re v2 lt gt Z m gt a kd Scientific General Information WARRANTY AND REPAIR INFORMATION Warranty KD Scientific warranties this instrument for a period of one year from date of purchase At its option KD Scientific will repair or replace the unit if it is found to be defective as to workmanship or materials This warranty does not extend to damage resulting from misuse neglect or abuse normal wear and tear or accident This warranty extends only to the original consumer purchaser IN NO EVENT SHALL KD SCIENTIFIC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages so the abo
8. uto Fill Valve Box High Pressure 788338 Continuous Delivery Valve Box Low Pressure 788332 Continuous Delivery Valve Box Medium Pressure 788335 Continuous Delivery Valve Box High Pressure 788337 Replacement Parts Description Catalog Number Replacement 3 Way Pinch Valve 5126035 Replacement 3 Way Solenoid Valve 5126045 Replacement Valve High Pressure 5126057 Bio Chem C Flex Replacement Tubing 5122033 I O Communication Kit 4400233 I O Communication Kit Legacy Valve Box 4400232 Valve Kits Description Catalog Number Low Pressure Auto Fill Kit 788345 Female luer lock to 1 16 barb 4 pcs union 1 16 barb to 1 16 barb 4 pcs amp C flex tubing 10 ft Low Pressure Continuous Delivery Kit 2x autofill kit 788346 Medium Pressure Nut Ferrule Auto Fill Kit 788347 Nut PEEK 1 16 1 4 28 3 pcs Ferrule flangeless 1 16 3 pcs amp Teflon tubing 5 ft Medium Pressure Nut Ferrule Continuous Delivery Kit 2x autofill kit 788348 Medium Pressure Barb Auto Fill Kit 788349 Barb 1 16 3 pcs amp C flex tubing 10 ft Medium Pressure Barb Continuous Delivery Kit 2x autofill kit 788353 Medium Pressure Luer Auto Fill Kit 788351 Female to male luer lock 1 4 28 1 pc Male to female luer lock 1 4 28 2 pcs Medium Pressure Luer Continuous Delivery Kit 2x autofill kit 788352 Specials Special valve box versions can be created additional quantity of valves various fitting types or different valve types to suit your application Please co
9. ve limitation or exclusion may not apply to you THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR OF ANY OTHER NATURE Some states do not allow this limitation on an implied warranty so the above limitation may not apply to you If a defect arises within the warranty period promptly contact KD Scientific 84 October Hill Road Holliston Massachusetts 01746 using our toll free number 1 508 429 6809 Email address is info kdscientific com Goods will not be accepted for return unless an RMA returned materials authorization number has been issued by our customer service department The customer is responsible for shipping charges for non warranty repairs Please allow a reasonable period of time for completion of repairs or replacement If the unit is replaced the replacement unit is covered only for the remainder of the original warranty period dating from the purchase of the original device This warranty gives you specific rights and you may also have other rights which vary from state to state Repair Facilities and Parts KD Scientific stocks replacement and repair parts When ordering please describe parts as completely as possible preferably using a part number obtained from our Technical Support department If practical enclose a sample part or sketch We offer a complete reconditioning service Serial Numbers All inquiries concerning our product should refer to the serial number of the unit lo