Contents

1. POWER MEASURE Mode of Operation In this mode the unit can measure current up to 24mA and power a 2 wire current loop The loop ES 209 PN E voltage is 24V Slide the function switch to the POWER MEASURE position Turn the meter ON Connect the Calibration Cable to the meter Connect the Calibration Cable to the loop Open the current loop at any convenient location along the signal path Read the measurement on the LCD display Use the UNIT button to select or mA units of measure In mode the display will read from 25 0 to 230 0 representing 0 00 to 50 00mA 5 412300A EU EN v3 4 07 13 Specifications General Specifications Display Meter Povver Auto Povver OFF Current output capability Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Dimensions Weight Accessories Supplied Range Specifications 9999 count LCD 9 volt battery or AC adaptor Meter automatically powers off after 10 minutes of inactivity 24mADC at 1000 ohms 5 C to 40 C 41 F to 104 F 20 C to 60 C 4 F to 140 F Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F lt 80 2000meters 7000ft maximum 96 x 118 x 45mm 3 8 x 4 7 x 1 8 folded 340g 12 oz 9V battery AC Adaptor and calibration cable with spade lugs Mode Function Range Resolution Accuracy of reading Measure Curre
2. 12mA 16mA 20mA 0 25 50 75 100 4 412300A EU EN v3 4 07 13 Modes of Operation MEASURE Input Mode of Operation In this mode the unit will measure up to 50mADC OU LO ci NC Slide the function switch to the SOURCE MEASURE position Turn the meter ON Press the MODE button to select MEASURE Connect the Calibration Cable to the meter Connect the Calibration Cable to the device or circuit under test Read the measurement on the LCD display SOURCE Output Mode of Operation In this mode the unit can source current up to 24mADC at 1000 ohms ON e CINI Slide the Mode switch to the SOURCE MEASURE position Turn the meter ON Press the MODE button to select SOURCE Use the UNIT button to select or mA units of measure Connect the Calibration Cable to the meter Connect the Calibration Cable to the device or circuit under test Use the A Y buttons to select the desired output value Use the LCD display to verify the output level Alternatively use the stored calibration values in Memory as described in the MEM button section Note that while the SOURCE display icon is blinking the calibrator is preparing to provide an output but only after the icon stops blinking will the current actually be sourced For the 25 to 125 output range the output is 0 to 24mA Refer to the Table below Display 25 0 25 50 75 100 125 mA OmA 4mA 8mA 12mA 16mA 20mA 24mA output
3. EXTECH User Guide INSTRUMENTS Model 4123004 Current Calibrator Introduction Congratulations on your purchase of the Extech Current Calibrator Model 4123004 The 412300A can measure source current and can also power a current loop A built in five location Memory can store customized calibration current output steps The Oyster Series meters have a convenient flip up display with neck strap for hands free operation This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Meter Description 1 LCD display Battery Compartment AC adaptor jack Calibration Cable input Function switch Neck strap posts No 9 2 N Keypad 2 412300A EU EN v3 4 07 13 Reypad and Svvitch Descriptions POWER BUTTON and AUTO POWER OFF FEATURE 1 Use the POWER button to turn the unit ON or OFF When the unit is powered up a short self test will ensue after which the display will stabilize This meter can either be powered by one 9V battery or an AC adapter When the battery symbol appears on the LCD display replace the battery as soon as possible Low battery power may cause inaccurate readings and erratic meter operation 4 This instrument is equipped with Auto Power OFF which turns the meter off after 10 minutes of inactivity To override this feature press and hold the MODE button until the display shows nft P auto power off de activated or At F auto power off activate
4. d FUNCTION SLIDE SVVITCH 1 Slide the Function switch on the side of the meter to the desired function Source Measure or Power Measure 2 In the Source Measure position the meter can be used to generate current or measure current MODE button is used to choose Source or Measure 3 In the Power Measure position the meter can power a current loop with 24Vdc and at the same time measure the current MODE BUTTON Press the MODE button to select either SOURCE output or MEASURE input This applies when the Function switch is set to Source Measure UNIT BUTTON Press the UNIT button to select mA or units A V INCREASE DECREASE BUTTONS Use the A V buttons to increase or decrease the output current value in the source mode 1 Press the A button once to increase the value in one digit steps 2 Press and hold the A button to increase the value in 10 digit steps 3 Press and hold the A button gt 2 sec and then press the V to increase the value in 100 digit steps 4 To decrease the value use the Y button as described above ZERO BUTTON The ZERO button manually zeros the display in the MEASURE mode 1 Set the meter to the MEASURE mode 2 Short the input jack 3 Press and release the ZERO button 3 412300A EU EN v3 4 07 13 MEM BUTTON The memory feature provides the user vvith five 5 user programmable source values for stepped calibration outputs The feature is available for mA and units in the SOURCE mode The sto
5. nt 0 to 50mA 0 01mA Percent 25 to 230 0 1 0 075 1 digit or 3 digits Source Current 0 to 24mA 0 01mA whichever is greater Percent 25 to 125 0 1 Power Loop Power 24VDC lt 50mA Battery Replacement When the battery symbol appears on the LCD replace the 9V battery as soon as possible 1 Open the calibrators lid as far as possible 2 With a coin or wide blade screwdriver open the battery compartment moving in the direction of the arrow embossed on the compartment cover location of compartment is identified in the meter description section 3 Replace the battery and close the battery compartment cover You as the end user are legally bound Battery ordinance to return all used batteries and accumulators disposal in the household garbage is prohibited You can hand over your used batteries accumulators at collection points in your community or wherever batteries accumulators are sold Disposal Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle Copyright 2013 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com 6 412300A EU EN v3 4 07 13
6. red values are kept in non volatile memory memory that is retained even after power is removed from the calibrator Source from the stored memory values 1 Select the Source mode as described earlier 2 Press the MEM button The M1 icon memory location 1 will appear in the display and the value stored in that location will be displayed and sourced 3 Repeated pressing of the MEM button will step through the 5 memory locations NOTE The SOURCE icon will blink when the output value has not reached a stable level The common cause for the SOURCE icon to remain blinking is that the load impedance is too high in the current mode Storing values into memory 1 As described above select and display a memory location M1 2 3 4 or 5 2 Use the A Y buttons to adjust the display to the desired source value 3 Press and hold the MEM button for gt 2 seconds The displayed value will be stored in the displayed memory location Default memory values Five common source values are permanently programmed in memory as the default values These values can be replaced by user selected values To reset the meter to the default memory values 1 Turn the meter on and select the SOURCE mode 2 Press and hold the POWER button until OFL E appears in the display and then release the POWER button The memory locations will revert to the default values Default Memory Values M1 M2 M3 M4 M5 mA 4mA 8mA

Download Pdf Manuals

image

Related Search

Related Contents

Scarica - Digital 2000 Srl  Dyno-Scan for Palm OS User Guide  Norsk, svenska and english user manual  Wiring Diagram  Hunter F42213 User's Manual  DATA SHEET Vibrio parahaemolyticus Real Time PCR Kit    NOTICE D`UTILISATION Race Company  1. Insert one end of the flat telephone cord  Honda HRM195PA User's Manual  