Home
KH8808 GSM INTELLIGENT ALARM SYSTEM User manual
Contents
1. host will not alarm if any of the detectors activated 4 When press emergency button no matter the host is in arm or disarm state will alarm immediately SOME TECHNOQUE PAPAMETER 1 Static current 20mA Power 9V 12V DC Working temperature 20 C 85 C GSM850 900 1800 1 900MHz band Receiving code ASK oof WP Frequency 315 433 868 915MHz Wireless distance 100M Wireless detectors 16 o N
2. in the back panel let the detectors send the signal after di sound learn successfully If the host has 5 wireless detectors stands for 1 5 wireless zones add one more detector the detector will be the sixth zone 3 When learn the remote controller press emergency button HOW CAN CANCEL THE LOST DETECTORS When wireless detector lost such as remote controller you need to cancel the coded information of this detector The way as follows Press reset button connect power supply then system reset After that all wireless detectors are canceled the password is 123456 all setting will be fault setting but the SMS will not be changed All the detectors should be learnt again the first one is in zone 1 the second one in zone 2 and so on HOW CAN USE CONTROLLERS The remote controller has four buttons outdoor alarm key disarm key emergency key indoor alarm key 1 When you press the outdoor alarm key signal lamp learning lamp and arm lamp will blink slowly together after 10 seconds only the arm lamp blink slowly means into arm state the host will alarm If any of the detectors activated 2 When you press the indoor alarm key signal lamp learning lamp and arm lamp will blink quickly together only the arm lamp blink quickly means into the arm state at this time the detectors learnt as outdoor can alarm learnt as indoor will not alarm 3 When press disarm key arm lamp in the panel lights at this time the
3. lamp light always means the system is in disarm condition HOW CAN SETUP THE ALARM PHONE NUMBER AND SMS 1 You can send the message to the base to setup the 5 group alarm phone number and 7 kinds of SMS The format password operation code content e g 123456 51 13005450001 Save the first group alarm phone number into the base 123456 52 13005450002 Save the second group alarm phone number into the base 123456 53 1 3005450003 Save the third group alarm phone number into the base 123456 54 13005450004 Save the fourth group alarm phone number into the base 123456 55 13005450005 Save the fifth group alarm phone number into the base 2 Set PSTN monitoring center You also can save phone number room No it will dial the room number when alarming For the users whose alarm system is working with monitoring center 123456 71 88886666 0001 show monitoring center 88886666 room No 0001 3 We have fixed 7 kinds of SMS in the base but you can change it The first five messages are for 1 5 zone wireless detectors the sixth messages are for 6 16 zone wireless detectors the seventh message are for wired port 11 12 I3 The first wireless detectors alarming the message is wireless detectors activated zone 1 The second wireless detectors alarming the message is wireless detectors activated zone 2 The third wireless detectors alarming the message is wireless detectors activated zone 3 The f
4. KH8808 GSM INTELLIGENT ALARM SYSTEM User manual FUNCTIONS 1 GSM850 900 1800 1900 bands alarm base for the world 2 It can store 5 group telephone numbers 3 Onsite voice Monitoring through telephone from long distance 4 Talk to onsite through telephone Set arm indoor and outdoor disarm emergency alarm through remote controllers 6 Call the system to arm disarm monitor scene setting etc 7 Send SMS to arm disarm monitor scene setting etc 8 Control the output ports to operate the light and air condition through call and SMS 9 It has 3 wired input ports it can check the open circuit short circuit 10 It has 16 wireless defense zones to connect with PIR detector smoke detector gas detector panic button and so on 11 When alarm it can control reply output in order to control power video etc 12 System has password to make sure the safety 13 Every wireless zone and wired zone can be arm disarm separately 14 15 SS wa Can use the rechargeable batteries Easy operation Wireless system Sketch Map of the front of panel Illustration 1 Arm indicator blink means in arm state light means in disarm state 2 Learning lamp in the first 20 seconds when panel connect power this lamp light please learn the remote and sensors 3 Signal lamp 20 seconds later it blinks with learning lamp and arm lamp searching the signal of GSM network Sw 4 5 OUT1 OUT2 6 Talk lamp light
5. e base 91 1 Set output 1 change to high 91 0 Set output 1 change to low 92 1 Set output 2 change to high 92 0 Set output 2 change to low 93 1 Set talk to the base avail ouput3 93 0 Set talk to the base no avail ouput3 94 1 Make two point of relay close 94 0 Make two point of relay open 95 1 Set alarm when line input 1 open 95 0 Set alarm when line input 1 connect to Gnd 96 1 Set alarm when line input 2 open 96 0 Set alarm when line input 2 connect to Gnd 97 1 Set alarm when line input 3 open 97 0 Set alarm when line input 3 connect to Gnd NOTE 1 Above table stand for approves 2 In the above phone operation one long beep di shows you inter each number is successful two short beeps shows you inter the sentence is failed you should try again HOW CAN I ADD MORE DETECTORS You can add new sensors or detectors such as wireless door sensors PIR Sensors gas and smoke detectors into the base 1 The detectors are all ready on alarm when you set Outdoor alarm or Indoor alarm when the GSM base start power on the learning lamp on panel will be bright in 20 seconds at this time let the detectors send the signal make sure the host has one di sound 2 If you want the detectors work when you are out but not work when you are at home you can set like this Power on the host within 20 seconds learning lamp lights press the RESET
6. ithout avail 18 1 Dial out when base change to arm 18 0 Not dial out when status base change to alarm status 19 1 Dialing when base change to disarm 19 0 Not dial out when status base change to disarm status 30 Show the arm and disarm status of every zone 31 Change password enter a new password 1 6 bit 38 Set on arm of zone wireless zone 1 16 wire zone 21 23 39 Set disarm of zone wireless zone 1 16 wire zone 21 23 5O0 Show preset phone number in the base 51 First group phone number 0 15 bit 52 Second group phone number 0 15 bit 53 Third group phone number 0 15bit 54 Fourth group phone number 0 1 5bit 55 Fifth group phone number 0 1 5bit 70 Show center phone number in the base 71 Set PSTN monitoring center phone number 71 center number room No 78 Set dial out phone number when you make base change to arm status this phone do not answer 79 Set dial out phone number when you make base change to disarm status this phone do not answer 80 Show preset SMS in the base 81 First group message 0 24 bit 82 Second group message 0 24bit 83 Third group message 0 24bit 84 Fourth group message 0 24bit 85 Fifth group message 0 24bit 86 Sixth group message 0 24bit 87 Seventh group message 0 24bit 90 Show output status in th
7. ourth wireless detectors alarming the message is wireless detectors activated zone 4 The fifth wireless detectors alarming the message is wireless detectors activated zone 5 The sixth to sixteen wireless detectors alarming the message is wireless detectors activated zone i i 6 16 The seventh wireless detectors alarming the message is wireless detectors activated zone l 1 3 for port 1 to 3 alarm 4 You can send the message to the base to rewrite 7 kinds of SMS every message cannot be more than 24 English characters e g 123456 81 Front door open Save the first group message into the base as first Wireless detectors alarming 123456 82 Middle door open Save the second group message into the base as second wireless detectors alarming 123456 83 Back door open Save the third group message into the base as third wireless detectors alarming 123456 84 Front window open Save the fourth group message into the base as fourth wireless detectors alarming 123456 85 Back window open Save the fifth group message into the base as sixth wireless detectors alarming 123456 86 Middle window open Save the sixth to sixteen group message into the base as sixth wireless detectors alarming 123456 87 UP floor open Save the seventh group message into the base as port 1 to 3 wire detectors alarming HOW CAN I TEST THE BASE ALARM OUT When you start the base if the base is in disarm status you can use remote con
8. troller aim button or send SMS 123456 1 1 to change the base into alarm status When the host is in the arm state the arm lamp lights press the A or B of the panel or use the wireless detectors wireless PIR wireless door sensor emergency button of the controller etc to activate the host to alarm 1 When the host open the function of SMS alarm it can send SMS according to the activated port wired IN1 IN2 IN3 ports or wireless detectors then dial the number to alarm If the SMS function has been closed then dial the number to alarm indirectly 2 When there is alarm you can answer the phone not need inter password for listen in remote control press 3 1 to make the base to play the siren and press 3 0 to stop it for monitoring 3 When there is alarm you can answer the phone to talk to the onsite not need inter password press 93 1 directly to allow the host base issue the voice of the master press 93 0 close the talk to monitor 4 When there is alarm the user answer the phone if it is not pirate of the situation press 1 1 to re turn the base in alarm status Then the base will not dial next phone number again 5 When there is alarm you can use the controller to change the base into disarm status when you are in nearby 6 In normal use with inside recharger battery you will receive the message external power failure or external power recovery when external power supply lost or recovery 7 Yo
9. u can control the system remotely through telephone input password before that Note when operate with mobile phone please press next button after listen the sound di If wrong press to re operate HOW CAN I CONTROL THE BASE 1 Sending the message to the host phone number SIM card number format password operate code E g send 123456 51 phone number Save the first phone number The host will reply if it receives the message 2 Calling the host phone number SIM card number call in the base and enter password 1234564 after di to set the function of the host it would be auto off if 30 seconds passed the correct password has not input The following command to set the base Com Function Com Function 1 1 Outdoor alarm all detectors work 1 2 Indoor alarm part detectors work 1 0 Disarm all detectors not work 3 1 Sounder immediately 3 0 Stop sounder 4 1 Start to listen in use phone key 4 0 Stop to listen in use phone key 11 1 Need siren sound when alarming 11 0 No siren sound when alarming 12 1 Sending SMS when alarming 12 0 No send SMS when alarming 15 1 Dial phone number when alarming 15 0 Just alarm and no dialing 16 1 Disable relay close 3 Min when 16 0 Set relay close 3 Min alarm when alarm 17 1 Set PSTN monitoring center avail 17 0 Set PSTN monitoring center w
10. when operate talk function 7 Relay 8 Monitor 9 Siren 0 Power 1 12 Check buttons MIC 13 14 Inside siren 15 Talk speaker 16 Antenna Sketch Map of the back of panel Illustration 1 SIM card guide use the needle press yellow point to pick out card guide put in the SIM card and then push back Adaptor jack 12V 1A adaptor Recharge switch when install the rechargeable battery open this switch to recharge for the battery 4 Reset press this button connect power supply system recover to the initial state password is 123456 all the detectors learnt are cleared 5 6 7 three wired ports 8 9 output ports to control small appliance 10 Relay output it closes 3 minutes when alarm 11 External siren 12 GND the port to connect with ground 13 12V power output it can supply the power of wired sensor 2 3 wo HOW CAN I START THE BASE Pick out the SIM card guide and install the SIM card Connect the adaptor 12V 1A or install the back up battery and open the switch Learning lamp light now it is the time of learning detectors 20 seconds later learning lamp signal lamp arm lamp blink slowly now system search GSM network signal and check the SIM state If system check successfully and the system has stored number inside then arm lamp blink slowly means the system in arm condition If the system check successfully but the system has not stored number inside the arm
Download Pdf Manuals
Related Search
Related Contents
iSense™ - Amazon Web Services Magic Bullet Basics DCエアーポンプ使用上のご注意 Instrucciones de servicio MicroLogix™ 1200 Programmable Controllers 作本書は、 お買上げの日から下記期間中故障が発生した場合に、 下記 Philips Sonicare DiamondClean Rechargeable sonic toothbrush HX9322 Sony 4-131-482-12(1) Flat Panel Television User Manual T-Mobile Communication Center Software Copyright © All rights reserved.