1. Mye Pce Distributor KHIND ALLIANCES SDN BHD 811092 W No 2 Jalan Astaka U8 82 Bukit Jelutong 40150 Shah Alam Selangor Malaysia Service Center 1 800 88 0032 Email kas inquiry khind com Website http www khindalliances com AirTek International Corporation Limited JMATEK International Group of Companies Manulife Financial Centre Kwun Tong Hong Kong Phone 852 2559 5522 Email info honeywellaircoolers com Web www honeywellaircoolers com Made in China 2015 AirTek Int l Corp Ltd All rights reserved The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representations or warranties with respect to this product This product is manufactured by Airtek Int Corp Ltd Honeywell
2. e Remove the batteries if the unit is not going to be used for an extended period of time Do not drop the remote control 2 REMOTE CONTROL CONTINUED e Do not mix different types of batteries such as alkaline carbon zinc or rechargeable batteries Do not mix old and new batteries e Exhausted batteries are to be removed from the product COOLER LOCATION Make sure to position the air cooler correctly before you set up and start using the product Please refer to the COOLER LOCATION section of the separate Safety amp Maintenance Guide FILLING WITH WATER CAUTION Unplug the unit from the electrical power outlet before filling or emptying the water tank Continuous Water Supply Connection For a continuous water supply you will need a garden hose that is connected to a main water supply e Locate the male connector at one end of the garden hose Insert the garden hose connector into the water inlet valve of the cooler Screw and tighten the water inlet valve onto the threaded part of the garden hose connector making sure the hose connector is secured to ensure there will be no leaks If there is leakage the hose and the water inlet valve may not be connected properly Try to disconnect replace and tighten the water inlet valve again e When the connection is secured turn ON the water supply and the water will flow into the water tank of the cooler e The cooler is now set so the water refills automatically when
3. tank with clean water up to the maximum level and drain it completely e Use a damp cloth to remove the dirt and dust from the surface of the unit Never use corrosive elements or chemicals to clean this product e When the product is not in use store the unit in a dry place our of direct sunlight CLEANING THE PLASTIC NET FILTER AND HONEYCOMB COOLING MEDIA e The appliance is supplied with a Plastic Net Filter and Figure 1 Honeycomb Cooling Media e The Plastic Net Filter and Honeycomb Cooling Media are located inside the Rear Grill See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance e Do not run the unit in COOL mode with stale water in the tank You must empty the water tank and refill with fresh water especially if the tank has not been cleaned in a long time e The cleaning frequency for the Honeycomb media Conte Mode Horizontal Bar depends on local air and water conditions In areas where the mineral content of water is high mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits If mineral deposits remain on the Honeycomb Cooling Media the media should be removed and washed under fresh water The media should be cleaned every two months or sooner depending on your needs e For best results allow the Honeycomb Cooling Media to dry after each u
4. the water tank is empty or when the water reaches below a minimum level e When the water tank is full the water inlet valve will automatically stop the water supply from overflowing WARNING The maximum water inlet pressure is 0 5 MPa Manual Water Tank Refill Open the Water Fill Door located on the side of the unit The Water Level Indicator is located at the front of the unit Refill the water tank when water level is low To avoid water spillage and water droplets at the louvers do not fill water above the MAX indicator level Check the water level in the tank before running the COOL function Make sure that the water in the tank is above the minimum water level mark Running the unit in COOL mode with inadequate water may cause pump failure Note If ice is available you may add ice in the ice tray to enhance the cooling performance a Water inlet valve Garden Hose A NIS N Water Fill Door I Ice Tray CLEANING amp DRAINING THE WATER TANK If the cooler will not be used for a long period of time please refer to the STORAGE amp MAINTENANCE GUIDELINES located in the separate Safety amp Maintenance Guide WARNING Before cleaning the unit switch the unit OFF and disconnect from the electrical socket e Move the unit to a location where the water can be drained Remove the cap from the Drain plug located at the bottom of the unit Allow the tank to empty e Refill the water
5. Honeywell Portable Evaporative Air Cooler User Manual Read and save these instructions before use Scan Here www honeywellaircoolers com www honeywellaircoolers com Model CL70PE E mail info honeywellaircoolers com 16 17 1 Control Panel 7 Power Cord Wrap 13 Rear Grill 2 Handle 8 Water Tank 14 Water Regulator 3 Louvers 9 Power Cord amp Plug 15 Water Fill Door 4 Water Level Indicator 10 Plastic Net Filter 16 Water Inlet Valve 5 Casters 11 Rear Grill Screw 17 Drain Plug 6 Ice Compartment Lid 12 Honeycomb Cooling Media WARNING READ AND SAVE THE AIR COOLER SAFETY amp MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND OR IMPAIR ITS OPERATION AND VOID THE WARRANTY CONTROL PANEL Icons on Display Screen Swing Bo 8 a8 SEAS O z Vertical Louvers 0 Fowo sway x MODE SPEED POWER TIMER SWING H kaa Cool Timer e f Speed Aa Swing Y Horizontal Louvers FUNCTION BUTTONS POWER Press the POWER button to turn the unit on The cooler will start automatically at medium speed After a few seconds the speed will switch to low To turn the unit off press the button again MODE Press the MODE button to activate evaporative cooling and or louv
6. e Honeywell Air Coolers provide cool moist air through the evaporation of water There is a manual Water Regulator knob located Water Regulator behind the ice compartment of the unit This allows you to adjust the MAX amount of water pumped over the Honeycomb Cooling Media thus helping 0 control cooling and humidification levels F Y When the Water Regulator is set to MIN the water pump distributes a e minimal amount of water to the Honeycomb Cooling Media This results in less water evaporation and reduces the cooling effect MIN When the Water Regulator is set to MAX the water pump distributes the maximum amount of water to he Honeycomb Cooling Media This results in maximum water evaporation and greater cooling performance REMOTE CONTROL POWER ON OFF SWING Controls the motion of the horizontal louvers TIMER Controls the Timer function for automatic off MODE Controls the motion of the vertical louvers and evaporative Cooling On Off SPEED Low Medium High Note e The remote control requires AAA 2 x 1 5V batteries for replacement Open the battery compartment at the back of the remote control and insert the batteries inside Care must be taken to insert the batteries according to the correct polarity markings shown inside the battery compartment e Always point the remote control signal transmitter towards the unit when operating Make sure that the signal path is not obstructed
7. er swing modes Press the MODE button until the S indicator light is illuminated on the control panel The Vertical Louvers will begin to move left to right automatically Press the MODE button until the C indicator light is illuminated to activate evaporative LOUVER cooling The water pump will operate and you will feel the cooler air after the Honeycomb MOVEMENT Cooling Media is completely wet FUNCTION BUTTONS CONTINUED Pressing the MODE button until both S and C are illuminated will activate both Swing Vertical Louvers and Cool modes simultaneously Note When the C mode is not selected the unit functions in a fan only mode without evaporative cooling SPEED Press the SPEED button repeatedly to change the speed between High Medium Low The indicator light will show the selected speed High H lt gt Medium M lt gt Lowi TIMER Press the TIMER button until the desired time duration setting is selected When the set time has passed the unit will automatically turn off unit remains in Standby mode until power cord is unplugged rom electrical socket The TIMER function allows you to program the unit for up to 7 5 hours of use SWING H Press the SWING H button until the indicator light turns on This activates the Horizontal Louvers and they will begin to move up and down automatically LOUVER MOVEMENT ROOM COOLING AND HUMIDIFYING n cooling mod
8. se by turning off the cool function 15 minutes before turning the unit off Rear Grill Screws Removing the Plastic Net Filter Honeycomb Cooling Media Slide out the Plastic Net Filter and clean with water Remove all the screws from the Rear Grill of the Air Cooler Carefully pull out the rear grill from the cooler Carefully pull out the Honeycomb Cooling Media from the rear gril There are two Horizontal Bars holding the Honeycomb Cooling Media in place Remove all the screws from the Horizontal Bars and then pull the bars off of the Honeycomb Cooling Media Replace or clean media with water and a damp cloth as needed a popa 2 WARNING DO NOT operate the Air Cooler when the Rear Grill or Honeycomb Media is removed from the Air Cooler or if there is a loose fitting Rear Grill or Honeycomb Cooling Media Doing so can cause serious injury or dangerous electrical shock Applicable for models with Plastic Net Filter only TECHNICAL SPECIFICATIONS Model CL70PE Voltage 220 240V Frequency 50Hz Wattage 330 W Water Tank Capacity 70 Liters 18 5 Gallons Cooling Media Honeycomb 706 W x 426 D x 1008 H mm rodut Dimenion 27 8 W x 16 8 D x 39 7 H in Net Weight 17 8 kg 39 2 Ibs ELECTRICAL WIRING DIAGRAM Version 220 240V 50Hz COOL SWING oD H M L COOL OSC Capacitor e i PCB1 PLUG Transformer LJ i