Home
OV-1000 Optical Time Domain Reflectometer (OTDR)
Contents
1. The screen is large enough to view both the trace and the event table simultaneously eliminating the need to toggle back and forth between the two Along with offering three OTDR test modes Auto Advanced and Template Trace the OV 1000 is future ready with the ability to accept protocol testing modules such as Gigabit Ethernet as they are made available Features Benefits e Rugged splash proof mainframe allows for testing in harsh conditions e 6 4 in color TFT touch is easily readable when testing indoors under artificial light and outdoors in the sunlight CORNING Discovering Beyond Imagination waa Corning Cable Systems OV 1000 OTDR Photo LAN731 OV 1000 OTDR Kit Photo LAN730 Dial and keypad make scrolling and selecting faster and easier Accommodates up to two field interchangeable modules eliminating the need to change modules as often Windows CE based technology with four second power up time allows the user to begin testing immediately Instantaneous AutoSync USB makes it easier and faster to transfer files and perform software upgrades Product Specifications OV 1000 Optical Time Domain Reflectometer OTDR Corning Cable Systems A LANscape Solutions Product Specifications OV 1000 OTDR Mainframe Parameter Specification Display Color touchscreen 640 x 480 TFT 163 mm 6 4 in Interfaces USB A main USB B remote RJ 45 LAN 10 100 Mb s compact f
2. 5 41 5 dB 400 ST41 Single Mode Long Range OTDR Module 1310 1550 1625 nm 41 40 38 dB 400 MDSD Multimode Single Mode Quad OTDR Module 850 1300 1310 1550 nm 26 25 35 34 dB Accessories UI SC Universal Interface Source Connector Adapter SC UI ST Universal Interface Source Connector Adapter ST Compatible UI FC Universal Interface Source Connector Adapter FC OA SC Power Meter Connector Adapter SC OA ST Power Meter Connector Adapter ST Compatible OA FC Power Meter Connector Adapter FC OA LC Power Meter Connector Adapter LC OTSBATCH PC Batch Processing Software CASE OV 1000 Hard Shell Transit Case with wheels PS OV 1000 Power Supply for 100 240 V AC with US line cord Notes 1 Various test fiber box configurations available for use as OTDR launch cables Please contact Customer Service for part numbers and pricing 2 OV 1000 products are available with options not listed above such as an enhanced screen for outdoor use extended range GeX power meter on mainframe protocol testing modules multitest module for optical power and return loss measurement and various other OTDR modules Contact Corning Cable Systems Customer Service for more information Corning Cable Systems LLC PO Box 489 Hickory NC 28603 0489 USA 800 743 2675 FAX 828 901 5973 International 1 828 901 5000 e www corning com cablesystems Corning Cable Systems reserves the right to improve enhance and modify the features and specifications of Corni
3. 0 38 42 5 41 5 39 5 3 3 3 8 10 10 Quad Module Dynamic Range Event Dead Attenuation Model Wavelength nm at 10 ps dB Zone m Dead Zone m 400 MDSD 850 20 1300 20 27 26 1 1 3 4 1310 20 1550 20 37 35 1 1 4 5 5 400 SD34 SD37 400 SD40 SD140 General Specifications 400 MD26 D135 ST37 ST137 D45 SD142 ST41 400 MDSD Distance Range km 0 1 0 3 0 5 1 3 1 25 2 5 5 10 20 1 25 2 5 5 10 20 MM 0 1 0 3 0 5 1 3 2 5 5 10 20 40 2 5 5 10 20 40 40 80 160 260 40 80 160 260 SM 1 25 2 5 5 10 20 40 80 160 260 Pulse Width ns 5 10 30 100 275 5 10 30 100 275 1000 10 30 100 275 1000 MM 5 10 30 100 275 1000 1000 2500 10 000 20 000 2500 10 000 20 000 SM 5 10 30 100 275 1000 2500 10 000 20 000 Multimode Launch Class CPR 1 or 2 N A N A Class CPR 1 or 2 Conditions Linearity dB dB 0 03 0 03 0 05 0 03 Notes 1 All specifications valid at 23 C 2 C 73 4 F 3 6 F with an FC PC connector unless otherwise specified Typical dynamic range with longest pulse and three minute averaging at SNR 1 gt Multimode dynamic range is specified for 62 5 um fiber a 3 dB reduction is seen when testing 50 um fiber Typical dead zone of multimode reflectance below 35 dB and single mode reflectance below 45 dB using a 5 ns pulse Typical dynamic range with three minute averaging at SNR 1 Typical dead zone of single mode modules for reflectance below 4
4. 5 dB using a 10 ns pulse 5 ns pulse for 400 SD34 SD37 SD135 ST37 ST 137 Typical dynamic range on NZDS fiber with a three minute average at SNR 1 Typical dynamic range at 1550 nm is 2 dB lower at 10 us and 1 dB lower at 20 us Typical dynamic range at 1550 nm is 2 dB lower Controlled launch conditions allow 50 um and 62 5 wm multimode fiber testing 4 Ly 6 7 8 9 continued CORNING am Discovering Beyond Imagination scape Fiber Cabling Solutions for Premises Networks AN OV 1000 Optical Time Corning Domain Reflectometer OTDR Pee p A LANscape Solutions Product Specifications continued 400 SD34 SD37 400 SD40 SD140 General Specifications 400 MD26 SD135 ST37 ST137 SD45 SD142 ST41 400 MDsD Loss Threshold dB 0 01 0 01 0 01 0 01 Loss Resolution dB 0 001 0 001 0 001 0 001 Sampling Resolution 0 04 to 2 5 0 04 to 5 0 08 to 5 MM 0 04 to 2 5 m SM 0 04 to 5 Sampling Points Up to 128 000 Up to 128 000 Up to 52 000 Up to 128 000 Distance Uncertainty 0 75 0 0025 0 75 0 0025 1 0 0025 0 75 0 0025 m x distance x distance x distance x distance Measurement Time User defined User defined User defined User defined 60 min maximum 60 min maximum 60 min maximum 60 min maximum Real time Refresh s Guaranteed lt 0 4 Guaranteed lt 0 4 lt 1 Guaranteed lt 0 4 Typical lt 0 3 Stable Source Output 1 5 1300 nm 8 400 SD34 5 1 5 1300 n
5. MDSD Dual Multimode 26 25 dB and Single Mode 35 34 dB with SC and ST Compatible Connector OTDR port and power meter adapters continued CORNING AR Discovering Beyond Imagination scape 5 Fiber Cabling Solutions for Premises Networks aa OV 1000 Optical Time Corning Domain Reflectometer OTDR e p A LANscape Solutions Product Ordering Information continued Part Number Description Mainframes Standard components on mainframes include 6 4 in color touch screen USB A B ports RJ 45 port and Compact Flash slot 1000 MAINF OTDR Controller 1000 MAINF VPM OTDR Controller with power meter and VFL OV 1000 Modules Includes SC OTDR port adapter s 400 MD26 Multimode OTDR Module 850 1300 nm 26 25 dB 400 SD34 Single Mode Short Range OTDR Module 1310 1550 nm 35 34 dB 400 SD37 Single Mode Mid Range OTDR Module 1310 1550 nm 38 37 dB 400 SD135 Single Mode Mid Range OTDR Module 1550 1625 nm 37 35 dB 400 ST37 Single Mode Mid Range OTDR Module 1310 1550 1625 nm 38 37 35 dB 400 ST137 Single Mode Mid Range OTDR Module 1310 1490 1550 nm 38 34 37 dB 400 SD40 Single Mode Long Range OTDR Module 1310 1550 nm 40 40 dB 400 SD140 Single Mode Long Range OTDR Module 1550 1625 nm 40 38 dB 400 SD45 Single Mode Extended Range OTDR Module 1310 1550 nm 43 5 43 5 dB 400 SD142 Single Mode Extended Range OTDR Module 1550 1625 nm 43
6. OV 1000 Optical Time Domain Reflectometer OTDR A LANscape Solutions Product Applications e Testing and troubleshooting of LAN telco CATV and FT Tx networks Description Corning Cable Systems OV 1000 Optical Time Domain Reflectometer OTDR provides testing flexibility by combin ing a rugged platform with field interchangeable multimode single mode and advanced testing modules All OTDR mod ules can be used as continuous wave CW light sources Available as options on the mainframe are a power meter and visual fault locator VFL The OV 1000 utilizes Windows CE technology allowing for a fast power up time of four seconds The OV 1000 has an 80 MB internal flash memory that typically stores up to 1500 traces and eliminates the need for a hard drive which can fail under extreme field conditions If extra storage capacity is needed the unit offers USB A B ports and a compact flash slot The OV 1000 OTDR product line offers a wide variety of multimode and single mode modules Modules are cross platform compatible between the OV 1000 and the OptiVisor 400 OTDR mainframes The OV 1000 has the capacity to hold up to two OTDR modules or one OTDR module and one advanced testing module at the same time Modules can be easily switched out in the field without the use of tools in just a matter of seconds The OV 1000 has a 6 4 in color touch screen that is resistant to shock water and most common chemicals used in the field
7. h SC and FC OTDR port adapters 1000BK SD45 Extended Range Dual Single Mode 43 5 43 5 dB with SC and FC OTDR port adapters 1000BK MD25 Dual Multimode 26 25 dB with SC and ST Compatible Connector OTDR port adapters 1000BK MDSD Dual Multimode 26 25 dB and Single Mode 35 34 dB with SC and ST Compatible Connector OTDR port adapters Deluxe Kits Deluxe Kits include OV 1000 Mainframe with power meter and VFL single mode and or multimode module s power supply battery appropriate OTDR port adapters CD with OTSView PC emulation software and user s man ual OTSBatch PC batch processing software cleaning supplies Quick Reference guide and hard shell transit case 1000DK SD34 Short Range Dual Single Mode 35 34 dB with SC and FC OTDR port and power meter adapters 1000DK SD37 Mid Range Dual Single Mode 38 37 dB with SC and FC OTDR port and power meter adapters 1000DK ST37 Mid Range Triple Single Mode 1310 1550 1625 nm 38 37 35 dB with SC and FC OTDR port and power meter adapters 1000DK ST137 FT Tx Single Mode 1310 1490 1550 nm 38 34 37 dB with SC and FC OTDR port and power meter adapters 1000DK SD40 Long Range Dual Single Mode 40 40 dB with SC and FC OTDR port and power meter adapters 1000DK SD45 Extended Range Dual Single Mode 43 5 43 5 dB with SC and FC OTDR port and power meter adapters 1000DK MD25 Dual Multimode 26 25 dB with SC and ST Compatible Connector OTDR port and power meter adapters 1000DK
8. lash fiber inspection probe connector port video Storage Internal 80 MB flash USB sticks 1 GB and 2 GB optional compact flash cards optional Batteries Rechargeable lithium ion Battery Operating Time 8 has per Bellcore TR NWT 001138 Power Supply AC DC adapter input 100 to 240 V 50 to 60 Hz 2 A max output 24 V DC 90 watts Operating Temperature Storage Temperature 5 to 50 C 23 to 122 F 40 to 70 C 40 to 158 F Relative Humidity 0 to 95 max non condensing Size H x W x D 32 2 x 19 7 x 10 9 cm 12 6875 x 7 75 x 4 3125 in Weight 2 5 kg 5 4 lb Vibration lt 1 5 g at 10 to 500 Hz on three main axes Mechanical Shock lt 760 mm on six sides and eight main edges according to GR 196 CORE Power Meter Calibrated Wavelengths nm 850 1300 1310 1490 1550 1625 1650 Detector InGaAs Power Range dBm 10 to 86 Uncertainty 5 3 pW InGaAs Display Resolution dB 0 01 max to 76 dBm 0 1 76 dBm to 86 dBm 1 86 dBm to min Automatic Offset Nulling Range Max to 63 dBm for InGaAs Tone Detection Hz 270 1000 2000 Visual Fault Locator VFL Laser 650 nm 10 nm Continuous wave CW Typical Pow in 62 5 125 pm 3 dBm 2 mW Notes 1 All specifications valid at 23 C 73 F Standard recharge time is 3 h Recharge temperature 0 to 35 C 32 to 95 F gt No
9. m 7 1550 nm Power dBm 4 5 all others Visual Fault Locator Laser 650 nm 10 nm Laser 650 nm 10nm Laser 650 nm 10nm Laser 650 nm 10 nm optional CW typical Pou in CW typical Pou in CW Pou maximum CW typical P in 62 5 125 ym 3 dBm 62 5 125 pm 3 dBm lt 800 pW 62 5 125 pm 3 dBm Notes Does not include uncertainty due to fiber index and sampling resolution Typical output power is given at 1300 nm for multimode and 1550 nm for single mode CORNING 7 ae Discovering Beyond Imagination scape Fiber Cabling Solutions for Premises Networks a OV 1000 Optical Time Corning Domain Reflectometer OTDR P acl A LANscape Solutions Product Ordering Information Part Number Description Basic Kits Basic Kits include OV 1000 Mainframe single mode and or multimode module power supply battery appropriate OTDR port adapter s CD with OTSView PC emulation software and user s manual cleaning supplies Quick Reference guide and hard shell transit case 1000BK SD34 Short Range Dual Single Mode 35 34 dB with SC and FC OTDR port adapters 1000BK SD37 Mid Range Dual Single Mode 38 37 dB with SC and FC OTDR port adapters 1000BK ST37 Mid Range Triple Single Mode 1310 1550 1625 nm 38 37 35 dB with SC and FC OTDR port adapters 1000BK ST137 FT Tx Single Mode 1310 1490 1550 nm 38 34 37 dB with SC and FC OTDR port adapters 1000BK SD40 Long Range Dual Single Mode 40 40 dB wit
10. ng Cable Systems products without prior notification LANscape is a registered trademark of Corning Cable Systems Brands Inc OptiVisor is a trademark of Corning Cable Systems Brands Inc Discovering Beyond Imagination is a trademark of Corning Incorporated ST is a registered trademark of Lucent Technol ogies Windows is a registered trademark of Microsoft Corporation USA All other trademarks are the properties of their respective owners Corning Cable Systems is ISO 9001 certified 2006 Corning Cable Systems All rights reserved Published in the USA LAN 748 EN July 2006 pdf CORNING am Discovering Beyond Imagination scape Fiber Cabling Solutions for Premises Networks saga
11. t including internal batteries Battery maximum storage temperature 60 C 140 F At 23 C 1 C 1550 nm and FC connector With modules in idle mode Battery operated Up to 5 dBm For 0 05 dB from 18 to 28 C CORNING Discovering Beyond Imagination Sia a continued 4 scape Fiber Cabling Solutions for Premises Networks OV 1000 Optical Time Domain Reflectometer OTDR A LANscape Solutions Product Specifications continued Corning Cable Systems Multimode Module Dynamic Event Dead Attenuation Model Wavelength nm Range dB Zone m Dead Zone m 400 MD26 850 20 1300 20 27 26 1 1 3 4 Single mode Modules Dynamic Range Dynamic Range Event Dead Attenuation Model Wavelength nm at 10 ps dB at 20 ps dB Zone m Dead Zone m 400 SD34 1310 20 1550 20 35 34 37 35 1 1 4 5 5 400 SD37 1310 20 1550 20 38 37 39 38 1 1 5 6 4 4 400 SD135 1550 20 1625 10 37 35 38 36 1 1 6 6 4 5 400 ST37 1310 20 1550 20 1625 10 38 37 35 39 38 36 1 1 1 5 6 6 4 4 5 400 ST137 1310 20 1490 10 1550 20 38 34 37 39 35 38 1 1 1 5 6 6 4 4 4 400 SD40 1310 20 1550 20 40 408 41 5 40 5 3 3 10 15 400 SD140 1550 20 1625 10 40 38 40 58 39 3 3 15 16 400 SD45 1310 20 1550 20 43 5 43 5 45 45 3 3 10 15 400 SD142 1550 20 1625 10 43 5 41 5 45 43 3 3 15 16 400 ST41 1310 20 1550 20 1625 10 41 4
Download Pdf Manuals
Related Search
Related Contents
Vector VEC1197 User's Manual Séjours été Jumelage Elections départementales - Bry-sur Impression 300XL RZ RGB Manual V1.2 EN TOA Electronics CST38MH User's Manual Opticon H19A Plaquette CAUE - Sauvigny-le-Bois functions - northwick.eu 取扱説明書の表示 HoMedics Brethe BRT-150 User's Manual Copyright © All rights reserved.