Home

RT4-5gc object module

image

Contents

1. CORTEX RT4 5gc object module V 2 5 User manual 2012 Table of contents KANA key red Ll a AA ee ASA 9 Kako 9 Working with module In GPRS moet uuu ee enn ee eer a ey ny eer Peer ka 9 DT AN iis cds tats caesar can orca canna KANA MANANG AG NAAAGNAS uals Gemma ies 11 Enclosure 1 Terminal block pli pUEFDOBE ici ei a a a eR x i Rx pama 11 Enciosurez Module GUT Basi cias geo Ra b da opc pan o ER SLK Sk Coa ER Ed s ERE ach COR e a 12 Enclosure 3 Module control commands acid uc tie aa aaa 13 Enclosure 4 Module configuration commands oa namana anakan LA a ERA Sola ace de iaiia 13 Enclosure 3 LELO AN COA nio HE Cn on t D mU IEEE rms ES 16 Korteks Zilupes iela 7 Riga Latvija Tel fakss 371 6 7505603 371 67505604 2 E mail info cortex lv http www cortex lv General information RT4 5gc object device is designed for collecting information from control panel it s processing and transmitting it to the Central Unit and or 4 registered mobile phones RT4 5gc also monitors the state and level of it s power supply and in case of trouble reports to the phone Device preferences Ability to transmit information via SMS and GPRS 63 event log RS 232 port for module settings programming GSM modem state and Signal strengths indication Power and data transmitting indication One programmable input Status input arming disarming 220V monitoring input 2 r
2. Master key for the device becomes the key that touched the reader first Master key registration is made the following way touch the reader with any key for approximately 1 second LED will turn red for 2 seconds This key is now registered as the master key User key registration is made the following way Touch the reader with the master key for approximately 1 second LED will flash red for 10 seconds If during that time K1 button will be pressed all previously registered user keys will be deleted and device will turn on programming mode Otherwise programming mode will be turned on in 10 seconds Programming mode is indicated by the constant red light After that touch the reader with the user keys with the 5 sec interval after each touch LED will blink fast Maximum number of user keys 20 To exit registration mode touch the reader with the master key again LED will turn green again Attention If the K1 button is pressed at the moment when you power up the device than all the keys including master key are deleted from the memory Working with module in SMS mode In SMS mode each user can receive information in two formats modem and user Format selection is made by user and depends on the module usage strategy Each user can change the format by sending message to the module Modem format is designed for receiving by CU GSM central unit and WinSC software User format is used if information
3. month yy year i ddMMyyhhmmss hh hours mm minutes ss Changes om e Set module Online identificator Changed XXXX identificator 15 digits g maximum Test period xxx time 10 minutes maximum 255 Changed 99 1 lt P gt Set IP address Changed ERES 99 DI IP Set DD EROR IP address if Changed 83 U4 used oe an Set domain name if used Changed name gt 99 A lt access De Response in Response in By default Command Description i i H user mode modem mode available to EC NEN of attempts to 99 R lt attempts gt connect to server Maximum Changed 255 99 O lt sec gt messages Changed Maximum 255 99 M lt min gt connect to server Changed 83 U1 Maximum 255 Set login for GPRS access Set password for GPRS 99 Y2 lt password gt access Maximum 8 Changed 83 U1 symbols Number of digits to determine phone number Changed 83 U1 Maximum 16 99 C1 Show network configuration Configuration Configuration 99 C2 Show general configuration Configuration Configuration 99 C3 Show mobile operator and iconfiguration Configuration U1 signal strength Note 1 Phone numbers may be entered both with international code and without it If you enter phone number with an international code than make sure to enter in front of it for example Latvia 371xxxxxxx Estonia 372xxxxxxx Russia 7xxxxxxxxxx Maximum number length 15 digits When changing Mast
4. S mode it is strictly recommended to program CU GSM central unit as master Module installing Before installing the module you have to make basic programming and configure other parameters After that you can install the module on the object When installing you should pay special attention to the antenna placement Close metal constructions may highly affect the signal strength For the signalization purposes module has the following inputs and outputs for external device connection general purpose input I3 Status input armed disarmed 14 220V monitoring input ACF 2 switchable inputs PGM outputs 11 03 12 04 2 general purpose outputs O1 O2 built in interface module for receiving information from security panels in Contact ID protocol optional RS 232 port for module programming By default all inputs are set as 24H doesn t depend on I4 status General outputs are made using open collector scheme and designed for maximum 1A current anf 15V voltage on the closed output PGM outputs are designed for maximum 10mA current and 5V voltage on the closed output Module inputs Device inputs are organized the following way 220V monitoring input strictly loaded to reacts on 0 break signals Doesn t depend on module status In order to monitor 220V you have to connect ACF input to the ACF output of the VSCS 1 5 VSC 3 0 12 devices or to the OUT output of the AC detector device O
5. T 1 T 2 AUxe AUX IF 1 4id LIKE oo POWER mm Control pannel Axe AUX Sena culpul ul Connecting using PARADOX 2 or IF Magellan interface modules Connecting TMR 20 device to the module Module can be armed and disarmed using touch memory keys In order to do so you have to connect TMR 20 reading device to the module To work properly RT4 5gc and TMR 20 must be configured the following way 11 03 contact must be configured as PRM output reacting to the zone alarm 12 04 and 13 inputs must be set as instant depend on module status J1 jumper on the TMR 20 device must be removed Wiring scheme is shown on the picture below uad cC n e 12 mm Lo DT 11032104 l n PwRL 01 o2 VOQVOOVQQOOOO NG o OOOOOCO TON RD GRN RED bUZ T p Black Led s red color Yellow Led s green color Red Data Blue Ground Arming Before arming RT4 5gc make sure that all the zones are in the normal state To arm the module just touch the reader with registered touch memory key Device will immediately arm LED will turn off every 4 seconds and corresponding message will be sent Disarming To disarm an object just touch the reader once again with the registered key LED will turn permanent green Touch memory key registration Key programming is made in a special mode that is activated by touching a reader with a master key
6. ccount and message format If itis impossible to program the module using Reader_for_gc_v 2 0 software you can program first user s number by SMS To do so insert activated SIM into the module beforehand deleting all the contacts from the SIM memory If PIN request is activated PIN code must be set as 0000 Power up the device After the PWR MODE LED turned green from any phone send a following message to the module 91 xx xx where xx xx first user s phone number if you register the phone number with international code you have to add before the number After that the first user will receive Security code message He has to answer that with the module security code 1234 by default Security code must be sent within 10 minutes time otherwise phone number will be deleted from the memory After all that is done the first user becomes the Master and further programming cam be made only from his phone Command and signal list is given in Enclosures Working with module Using the GPRS mode module can transmit information directly to the WinSC software or to any Central Unit that supports SIA IP protocol Module can send information to 4 users You can program message delivery depending on the event for every user and each user s ability to control module First registered user becomes a master and by default receives some exclusive rights for module control and programming see enclosures 2 4 If you use module in GPR
7. emotely controlled general purpose outputs 2 switchable inputs PGM outputs Central unit and or user s mobile Built in interface for collecting information from security panel in Contact ID protocol optional SIA IP protocol support Supports up to 4 users Two switchable message modes User and Modem Periodic channel test Technical information GSM protocol GSM modem SIM interface Number of users Output capacity PGM output capacity Maximum voltage on closed output Maximum voltage on closed PGM output Maximum voltage on closed inputs Supply voltage Input current at 12V supply Input current in GPRS mode Overall dimensions mm E GSM 900 1800 GPRS Quectel M10 3 and 1 8 V 4 1A 10mA 15V 5V 15V 11 15V 15mA 150mA 160x70x25 Module appearance CORTEX RT 4 5 gc Security system GSIW GPRS Transceiver OOOOOOOOOOOUO Pic 1 RT4 5gc module GSM antenna connector SIM holder Jumpers Programming joint Power and mode indicator GSM indicator Terminal block for power supply and external device connection QUE DU dM NS Pic 2 GSM antennas Basic programming Module programming is made using Reader_for_gc_v 2 0 software To activate the programming mode just connect the programming cable to the module When the PWR MODE LED will turn orange you can start programming the module At first you have to program first user s phone number module a
8. er new master will receive Security code message Mew Master must reply to this message with the security code 1234 by default within 10 minutes Otherwise previous number will be restored as Master Module adds time to all the messages in user mode for example 14 37 11 Ready Module adds time and date to all the messages in modem mode for example FF 1234 96 lt date gt lt time gt To set correct time you have to either turn on GPRS mode or send special SMS message Attention After restarting module time and date will be lost If you have to switch from connecting using domain name to connecting using the IP address you just have to delete DNS server IP address To do so just send 99 DI command to the module Appropriate signal strength 15 20 points good 20 30 Enclosure 5 List of event codes a Out 1 activated Out 2 activated Out 3 activated Out 4 activated Confirmation of receiving Enter programming mode command User 2 deleted User 3 deleted User 4 deleted ga Account Security code is changed Forced exit from GPRS Module configuration changed zem Error establishing GPRS connection eem Error connecting to Central Unit
9. is send to the mobile phone Working with the phone numbers of the defined length Module can define phone number by the specified number of digits instead of the whole number Symbol count starts from the end of the number Maximum number of symbols is 16 is not counted Number of symbols is set using 99 Nx command where x number of symbols If you will send 99 N0 command module will work only with fully specified phone numbers By default number length is set as 8 This option can be configured using Reader for gc v 2 0 software Working with module in GPRS mode When using GPRS module sends information directly to the WinSC software or to any central unit that supports SIA IP protocol Attention In GPRS mode module ignores any SMS messages received from the first user and doesn t send him any SMS GPRS connection settings To work in GPRS properly you have to configure the following parameters APN Access point name for accessing GPRS IP address TCP PORT Domain name if used DNS Server IP if used Thees parameters can be defined using Reader for gc v 2 0 software or by SMS command 99 I IP Server IP address 99 A access point APN 99 P lt port gt TCP port 99 R lt attempts gt Number of attempts to reconnect to i p server Time between reconnection attempts 99 DI lt IP gt DNS server IP address if used 99 DD lt domain name gt Domain name if used You can configure the module to auto
10. ivate Output 1 Status Status Activate Output 1 on time Status Status vn U2 Xxx time in minutes 03 1 Activate Output 2 Status Status U1 U2 Gg Deactivate Output 2 Status Status U1 U2 FINALE Hutput S On time Status Status U1 U2 Xxx time in minutes 5 Activate Output 3 Status Status U1 U2 6 Deactivate Output 3 Status Status U1 U2 Sax Activate Output 3 on time Status Status U1 U2 Xxx time in minutes Activate Output 4 Status Status U1 U2 8 Deactivate Output 4 __ Status Eu EF CE U2 Xxx time in minutes Turn on programming mode xxxx security Programming code Note 1 Status shows current module state armed disarmed and lists all the alarmed inputs and activated outputs Enclosure 4 Module configuration commands Table 4 user mode modem mode available to Set Re module state as e 1 st user s phone Request 2 nd user s phone Command Description Response in i Response in By default user mode modem mode available to Request 3 rd user s phone Request 4 th user s phone Change master s phone Security i 2 26 U1 number code number number number Change module account Code is 95 xxxxyyyy XXXX security code yyyy 30 U1 changed new account Change module security code Code is 96 xxxxyyyy XXXX current code yyyy 30 U1 changed new code XXXX security code Set module date and time dd 99 C day MM
11. matically go into GPRS mode and connect to server after powering on To do so you have to set number of attempts to reconnect to server 255 Attention If module sends messages in SIA IP protocol this option is ignored and module connects to server only when transmitting information Forced exit from GPRS mode For power saving purposes module can exit GPRS mode if there are troubles with power supply You can specify conditions on which module will exit GPRS Those can be specified either by Reader for gc v 2 0 software or by the following SMS commands 99 F0 Don t exit GPRS unless command 86 security code is received 99 F1 Exit GPRS if power low 99 F2 Exit GPRS if 220V lost 99 F3 Exit GPRS if power low or 220V lost If this option is activated than after exiting GPRS module will send the followng SMS message 71 in modem mode or Check bat or power in user mode Attention If module sends messages in SIA IP protocol this option is ignored and module connects to server via GPRS anyway Mobile operator authorization for GPRS activation In case if for GPRS activation you need to authorize with the mobile operator you have to specify login and password Those can be specified either by Reader for gc v 2 0 software or by the following SMS commands Login is set by the 99 Y1xxxx command where xxxx login Password is set by the 99 Y2xxxx command where xxxx password Number of symbols in login and
12. password must not exceed 8 If you have to delete login or password send the following commands to the module 99 Y1 delete login and 99 Y2 delete password Online identificator In order to send a message to the module from the WinSC software you have to assign a unicque ID for it It is recommended that ID would be the same as phone number Attention ID must only contain digits and be maximum 15 symbols long You can set online ID either by using Reader for gc v 2 0 software or by using 99 Wxxxx messages where xxxx identificator By default online ID is set as 11111111 By sending 99 Wi command you can set Online ID as GSM modem IMEI Possible errors f failed to establish GPRS connection GPRS error in user mode or command 85 in modem mode Possible cause wrong APN login or password are set GPRS not allowed for this SIM Failed to connect to software or central unit Online error in user mode or command 88 in modem mode Possible cause wrong IP address or TCP port are set Firewall blocks connection Indication There are two LEDs used for indication Flashing green once every 2 3 seconds SOM PONG ANG or signalat high Flashing orange once every 2 3 GSM coverage OK GSM signal at medium seconds level Flashing red once every 2 3 seconds GSM coverage OK GSM signal at low level Flashing red once per second Out of GSM coverage Enclosure 1 Terminal block pin purpose Table 1 Power sup
13. ply Pins for connecting interface modules or security panel phone communicator Alarm input 1 PGM1 Alarm input 2 PGM2 Alarm input 3 Status input 220V monitoring input Output 1 Output 2 In order to monitor 220V you have to connect ACF input to the ACF output of the VSCS 1 5 VSC 3 0 12 devices or to the OUT output of the AC_detector device Otherwise you can use it as general alarm input Enclosure 2 Module events Table 2 Event in User Event In mode Out t activated 1 activated ot oo wo eem om fw oo pws Tan Bem 9m o la pow ef Meer eee meme wef pamo Tma we UN FF Note 1 Message text may be edited Text given is a default 2 In modem mode before the code there are always added format identificator and module account and after the code checksum For example test message in modem mode will look the following way FF 1234 96 lt date gt lt time gt lt CS gt where CS checksum If there are several event coded in the message status request than event codes are separated with the comma FF 1234 35 94 32 lt date gt lt time gt lt CS gt 3 U1 U2 U3 U4 User numbers U1 Master Enclosure 3 Module control commands Table 3 Command Description Response In ugar i Ros pong T By default available to mode modem mode E Change message mode Status Status Recuest module status Status Status Activate Output 1 Status Status Ka Deact
14. therwise you can use it as general alarm input Alarm and status inputs can be loaded both on O and on Choice is made using jumpers Jumper 1 corresponds to alarm on zone 1 input 2 alarm on zone 2 input 3 alarm on zone 3 input 4 status input Removed jumper provides load on reacts on 0 break signals set on O reacts on break signals Counting from the programming joint Maximum voltage on input 15V All alarm inputs 1 3 by default active 24 hours a day After connecting external devices to inputs object should be armed and the 00 xxxx command must be sent to module where xxxx security code With this command all input status is accepted as normal and module status armed RS 232 port has standard voltages and designed to work with cable up to 30m Connecting module with built in interface to security panel Module is connected to the panel s phone communicator Module s C R contact is connected to the panel s RING contact Module s D T contact is connected to the panel s TIP contact Security panel must transmit information in automatic Contact ID codes in DTMF format and call to the number 2 Control pannel TIP RING T 1 T 2 AUxe AUX Connecting module without built in interface to different security panels Control pannel TIP RING T 1 T 2 Connecting using IF 1 2u interface module Silent Knight protocol Control pannel TIP RING