1. DBD VI al nd Ek we 12 fr kb LEDPRODUCTS AVIS LIPS YOUR PARTNER IN LED LIGHTING LED Tunnel Light User Manual BBM LEDLIGHTPRODUCTS BV Phone 0031 0 75 6405471 Fax 0031 0 75 6212509 info bbmledproducts com adviseurs gt BM LEDPRODUCTS YOUR PARTNER IN LED LIGHTING Important Notice The user must follow the method of connection on the USER MANUAL otherwise our company shall not be held liable for any hurts or damages occur on people or products itself because of maloperation Warning Please install the product according to the manual or it may cause electric shock or fire because of incautious operation Please do not use the product in the environment which the shock or vibration frequently happens easy to burn or there is a corrosive gas or it may cause drop or electric shock At least 1 meter distance from the surface to be illuminated or it may cause fire Change or modification of the product is prohibited or it may cause the electric shock spark or drop Lamp must have reliable grounding measure Therein yellow and green line is grounding light blue line is null line brown line is live line or it may cause the fire or electric shock In process of starting up or using please turn off the power immediately once there is smoking or unusual smell Cautions Please check if the lamp is broken during transportation and hold the original packing materials till all of the pro
2. line is live line BBM LEDLIGHTPRODUCTS BV Phone 0031 0 75 6405471 Fax 0031 0 75 6212509 info bbmledproducts com mkb s r DIV adviseurs LEDPRODUCTS YOUR PARTNER IN LED LIGHTING 4 Angle Adjustment Rotation 1 CP Dy Horizontal m WS j AQ N Left side down 35 Right side down 35 GN TITT PI Ground Mounted Bracket Ground or wall Rotating Center a gt lt s Horizontal a 77 SL i Left side down 35 z A mer ASL ae AG ARNT Ground or wall Rotating Center BBM LEDLIGHTPRODUCTS BV Phone 0031 0 75 6405471 Fax 0031 0 75 6212509 info bbmledproducts com
3. Fax 0031 0 75 6212509 info bbmledproducts com Dmkb SBM LEDPRODUCTS YOUR PARTNER IN LED LIGHTING Environment Condition adviseurs 1 Installation environment Outdoor in tunnels or indoor cannot be installed on objects apt to burn 2 Wind resistance Wind force lt 36m s 3 Atmospheric pressure 86kPa 106kPa 4 Sea Level lt 4000M b Working temperature 402C 502C 6 Relative humidity 10 95 Lamp Installation 4 I Lamps mounted on ground or wall M10 Steel Expansion Bolt in ground or wall ry Ground or wall na Lamps insert through M10 Steel Expansion Bolt N VA I EN N N WM EQN Thread Hole hy cs ke KN N aN Ground or wall BBM LEDLIGHTPRODUCTS BV Phone 0031 0 75 6405471 Fax 0031 0 75 6212509 info bbmledproducts com SBM LEDPRODUCTS mkb adviseurs YOUR PARTNER IN LED LIGHTING Lock the 4pcs M10 nuts in anticlockwise direction using N adjustable wrench or 16 wrench Lamp mer 4 M10 Nut SAAN i i ACRE 4 M10 Spring Washer r 4 M10 Washer M10 Steel Expansion Bolt in ground or wall Ground or wall 4 Wiring Diagram Note If there is lamp external cord broken or damage only manufacturer or agent authorized by the manufacturer can change the cord in case of any danger AC input cables shall not less than 1 25mm 7 Attention Yellow and green lines are grounding lines blue line is null line and brown
4. ducts and spare parts are checked and listed The product can t be dissembled by unprofessional person and must make sure the power off before disassembling or maintaining The street light can t be disassembled before turning off the power Hand touch of the circuit is prohibited The tools or testing equipments which guide the exterior electronical signal into system equipment is prohibited Such electronical signal can permanently damage the equipment There is isolation protection layer on circuit board please do not touch the acidic materials when you disassembling the circuit board like sweat etc Please use plate washer water to clean the circuit board when there is stain or dust The electrical leakage is possible when the lamp is transferred from cold environment to warm environment so please make sure the grounding to be implemented strictly The maintenance for the lamp have to wait at least 5 mins after turning off the power due to the capacity have enough time to discharge and keep the lamp cool Please pay attention not to hand touch areas which marked with Security Warning or High Voltage or electric shock and scald may occur BBM LEDLIGHTPRODUCTS BV Phone 0031 0 75 6405471 Fax 0031 0 75 6212509 info bbmledproducts com BBM Ons LEDPRODUCTS YOUR PARTNER IN LED LIGHTING Only professional or authorized person can operate to connect the lamp with the power The lamp shall work under specif
5. ication condition Main Technical Parameter 1 2 Sy 4 I 6 L 8 9 10 diy Rated Output Power W Rated Input Voltage 100 240Vac 100 277Vac Rated Input Frequency Range 47 63Hz Power Factor 20 95 Protection Rating IP65 Rated Initial Luminous Flux Im Rated Color Temperature K Beam Angle 100 90 Net Weight Kg Gross Weight Kg Maximum Illumination Area m 2MQ Insulation Resistance Insulation resistance between AC input end and lamp bodies is over 2MQ Volt AC1440V Dielectric Strength AC1440V between AC input end and lamp body for 1 min no sparkles breakdown or flashover 0 50 Safe grounding There is ground terminal for safe protection Ground terminal is in good connection with lamp body the contact resistance is less than 0 50 between ground terminal and lamp body BBM LEDLIGHTPRODUCTS BV Phone 0031 0 75 6405471 Fax 0031 0 75 6212509 info bbmledproducts com GER adviseurs G i Q a jo an Lid lt YOUR PARTNER IN LED LIGHTING Structure Tempered Glass Side Section Combined Reflector LED Aluminum Base Heat Sink AN AN L A A Metal Clip M18x1 5 L j Y i Hex Head Bolt M16x70 Power Supply Toggle khas Scale Type Upper Bracket 9 Hex Head Bolt M16x35 DOG Ground Support BBM LEDLIGHTPRODUCTS BV Phone 0031 0 75 6405471