Brocade Network Advisor SAN Installation and Migration Guide, v12
Contents
1. For example taskkill F PID 3328 OR 1 Select Ctrl Shift Esc to open Windows Task Manager 2 Click the Processes tab 3 Click the PID column header to sort the processes by PID 4 Select the process you want to stop and click End Process Brocade Network Advisor SAN Installation and Migration Guide 25 53 1003747 02 2 Installing the ODBC driver Installing the ODBC driver 26 You must have the Open Database Connectivity ODBC driver to allow remote clients to export data and generate reports The ODBC driver enables you to configure the data source name DSN for the Network Advisor database Installing the ODBC driver on Windows systems You must have the Open Database Connectivity ODBC driver to allow remote clients to export data and generate reports The ODBC driver enables you to configure the data source name DSN for the Network Advisor database To install the ODBC driver complete the following steps 1 Right click psqlodbc exe located olocated where you downloaded the software Download_Home BROCADE Network Advisor odbc Windows and select Run as administrator Install the file to the usual location for your system s application files for example C Program Files Network Advisor ODBC Driver on the Select Install Folder screen and click Next NOTE If you select an invalid location the ODBC driver is installed in a different location than where the ODBC executable drivers
2. 3 Click Start on the Data Migration screen Data migration may take several minutes When data migration is complete the previous version is partially uninstalled 48 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Migrating data 3 4 Click Next on the Data Migration screen If you have products associated with the Brocade North America or Brocade International Call Home centers a message displays To map these Call Home centers to the Brocade E mail Call Home center after migration click Yes To not map these Call Home centers click No NOTE Make sure you configure the Brocade E mail Call Home center refer to the Brocade Network Advisor User Manual or online help If you are migrating from Professional or Trial software continue with step 5 If you are migrating from Licensed software go to step 6 5 Select one of the following options on the Installation Type screen and click Next NOTE The DCX and DCX 8510 8 Backbone chassis require Enterprise edition e Network Advisor Licensed version Continue with step 6 Requires you to enter a license key during configuration to enable features and configuration e Network Advisor 120 days Trial Go to step 7 Enables you to manage SAN networks from a single interface for 120 days ATTENTION If you choose to install Trial once the trial period ends 120 days you must upgrade to Licensed software e Network Advisor Professional Go
3. Professional Plus Yes Yes Enterprise Yes Yes A Switch port enable disable through right click menu Yes Yes Yes Technical SupportSave Yes Yes Yes Telnet NOTE Telnet through the server is only supported on Windows systems Tools launcher Setup Tools Yes No Yes Yes Yes Yes Troubleshooting and Diagnostics Device connectivity troubleshooting wizard Yes Yes Yes Trace route and Ping Yes Yes Yes Fabric device sharing No Yes Yes User management No Yes Yes View management Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 No Yes Yes 65 A Edition feature support TABLE 15 SAN features supported Continued Feature Professional Professional Plus Enterprise Virtual fabric support Discovery Yes Yes Yes Configuration No Yes Yes VLAN management Yes Yes Yes VM Plugin Support No Yes Yes Web Element Manager Yes Yes Yes Zoning Member selection Yes Yes Yes Zone editing Yes Yes Yes Live fabric library scope Yes Yes Yes QoS support Yes Yes Yes Zone alias support Yes Yes Yes Delete Zone database No Yes Yes Impact analysis Yes Yes Yes Remove offline devices No Yes Yes TI Zones Yes Yes Yes Device to Zone zoneset participation analysis Yes Yes Yes LSAN Zones No Yes Yes Rolling back to an activated zone database No Yes Yes Import or exp
4. Uninstalling from Windows systems headless uninstall If the application was installed using the headless installation complete the following steps to uninstall Network Advisor and SMI Agent from your Windows server 1 Open a command prompt 2 Choose one of the following options e To partially uninstall Network Advisor configuration and performance data is retained to be re used by the new installation execute Install Home Uninstall_Network Advisor 12 4 1 Uninstall_Network Advisor 12 4 1 exe f lt absolute path of partial uninstall property file gt e To fully uninstall Network Advisor all data is removed execute Install_Home Uninstall_Network Advisor 12 4 1 Uninstall_Network Advisor 12 4 1 exe f lt absolute path of full uninstall property file gt When uninstallation is complete an Uninstallation complete message displays You must manually delete the Install_Home silent folder Uninstalling from UNIX systems Follow these instructions to uninstall the Network Advisor and SMI Agent from your UNIX system NOTE The Uninstall folder is retained 1 Go to Install_Home Uninstall_Network_Advisor12_4_ 1 Execute Uninstall_Network_Advisor12_4 1 3 Select one of the following options on the Uninstall Option screen e Partial Uninstall Configuration and performance data is retained to be re used by the new installation This is the default option e Full Uninstall All data is removed 4 Click Uninstal
5. Generates a unique identifier based on the MAC address The operating system such as Windows or Linux e User actions Top level menu actions Tool bar actions Right click menu actions e Feature details Feature name Button identifier such as OK Help or Cancel and so on Enabling product improvement data transfer You can enable feature usage data transfer during installation or migration For more information refer to Installation on page 1 You can also enable data transfer from the Options dialog box once your system is up and running To enable feature usage data transfer from the application complete the following steps 1 Select Server gt Options The Options dialog box displays 2 Select Product Improvement in the Category list 3 Select the Yes want to participate option To view an example of the usage data click View Example Data 4 Click OK to save your selection and close the Options dialog box Brocade Network Advisor SAN Installation and Migration Guide 35 53 1003747 02 36 2 Product improvement Disabling product improvement data transfer You can disable feature usage data transfer from the Options dialog box once your system is up and running To disable feature usage data transfer from the application complete the following steps 1 Select Server gt Options The Options dialog box displays Select Product Improvement in the Category list Select the No thank y
6. ANU A FTOOXOO54E9 The serial number label is located as follows Xvi Brocade 300 4100 4900 5100 5300 7500 7800 8000 VA 40FC and Brocade Encryption Switch On the switch ID pull out tab located inside the chassis on the port side on the left Brocade 5000 0n the switch ID pull out tab located on the bottom of the port side of the switch Brocade 7600 On the bottom of the chassis Brocade 48000 Inside the chassis next to the power supply bays Brocade DCX On the bottom right on the port side of the chassis Brocade DCX 4S On the bottom right on the port side of the chassis directly above the cable management comb Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 4 World Wide Name WWN Use the licenseldShow command to display the WWN of the chassis If you cannot use the licenseldShow command because the switch is inoperable you can get the WWN from the same place as the serial number except for the Brocade DCX For the Brocade DCX access the numbers on the WWN cards by removing the Brocade logo plate at the top of the nonport side of the chassis Document feedback Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document However if you find an error or an omission or you think that a topic needs further development we want to hear from you Forward your feedback to documentation brocade com Provide the tit
7. Professional Go to step 6 Bundled with Fabric OS and lronWare OS devices to manage small IP or SAN networks from a single interface SMI Agent is not available with Professional Licensed software only If you are installing licensed software browse to the license file xml and click Next on the Server License screen You can also copy Ctri c and paste Ctrl v the license key in to the License Key field The License Key field is not case sensitive 6 Complete the following steps on the FTP SCP SFTP Server screen a Choose one of the following options e Select Built in FTP SCP SFTP Server default to configure an internal FTP SCP SFTP server and select one of the following options Select Built in FTP Server to configure an internal FTP server This is the default option The internal FTP server uses a default account and port 21 You can configure your own account from the Options dialog box For instructions refer to the Network Advisor User Manual or online help Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Configuring Network Advisor 2 Select Built in SCP SFTP Server to configure an internal SCP SFTP server The internal SCP SFTP server uses a default account and port 22 You can configure your own account from the Options dialog box For instructions refer to the Network Advisor User Manual or online help e Select External FTP SCP SFTP Server to configure an external FTP server
8. 0000 annaran eee ee 35 Enabling product improvement data transfer 35 Disabling product improvement data transfer 36 Data transf r a oaea id tte a Sie hee ice Bed Se eek Gees 36 Configuring remote client access to the database 37 Chapter 3 Data Migration Upgrading the license ires 0 0 ce eee 39 Supported migration paths 0 00 cee eee 40 DCFM migration pathS 0 0 0 cece eee 42 INM migration pathS 0 cece 43 EFCM and Fabric Manager migration paths 43 Pre migration requirements 00 annaran n eee eee 43 Pre migration requirements when migrating from one server to another 0 000 cee eee 44 Additional pre migration requirements on UNIX systems 47 Additional trial requirements 00 ce eee eee eee 47 Migrating date wicca view ts wee ele ee Mi er ive Bey Ble Pahi 48 Cross flavor migration 1 0 0 cece eee 53 Migration rollback 1 2 ee eee 54 Migration rollback due to insufficient space 54 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Chapter 4 Uninstallation Uninstalling from Windows systems Uninstalling from Windows systems headless uninstall Uninstalling from UNIX systems Uninstalling from UNIX systems headless uninstall Appendix A References Network Advisor packages Scalability limits Edition feature support Management server and client ports Brocad
9. 64 bit Oracle Enterprise 6 4 x86 64 bit Oracle Enterprise 6 5 x86 64 bit Oracle Enterprise 7 0 x86 64 bit SF SS VMware ESXi 5 1 VMware ESXi 5 5 Microsoft Hyper V Hyper V Server 2008 R2 Win dows Server 2012 Windows Server 2012 R2 Data Center KVM RH 6 5 Supports all client OS versions available for Windows and Linux Memory requirements are only applicable when there are no other applications running on the Network Advisor server Paging space should be equal to or exceed the physical memory size NOTE To manage more than 9000 SAN ports you must have a 16 core processor NOTE To efficiently manage more than 9000 SAN ports it is recommended to allocate a minimum of 2 GB client memory and 6 GB server memory Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 System requirements 1 NOTE It is recommended that you add an additional 40 GB of disk space for the default temporary directory NOTE If you enable periodic supportSave or configure the Network Advisor server as the Upload Failure Data Capture location for monitored switches you must add additional disk space Each switch supportSave file is approximately 5 MB and each Upload Failure Data Capture file is approximately 500 KB To determine the disk space requirements multiply the frequency of scheduled supportSave files by 5 MB and the
10. Click Yes to close the message If you enter a port number already in use a Warning displays next to the associated port number field Edit that port number and click Next If you are configuring Professional software go to step 12 10 SAN with SMI Agent Complete the following steps on the SMI Agent Configuration screen a Enable the SMI Agent by selecting the Enable SMI Agent check box b Enable the SLP by selecting the Enable SLP check box if necessary Only enabled after you select the Enable SMI Agent check box c Enable the SSL by selecting the Enable SSL check box if necessary Only enabled after you select the Enable SMI Agent check box Brocade Network Advisor SAN Installation and Migration Guide 19 53 1003747 02 2 Configuring Network Advisor 11 12 13 14 d Enter the SMI Agent port number in the SMI Agent Port field default is 5989 if SSL Enabled is selected otherwise the default is 5988 e Click Next SAN Enterprise or SMI Agent Select one of the following options on the SAN Network Size screen and click Next NOTE Port count is equal to the total number of switch ports across all fabrics NOTE SAN with SMI Agent IP edition is not supported on a 32 bit Windows system e Small managing up to 2000 switch ports 1 20 domains e Medium managing up to 5000 switch ports 21 60 domains e Large managing up to 15000 switch ports 61 120 domains NOTE For full performance and dashboard f
11. Configuring backup in the Brocade Network Advisor User Manual or online help 2 Install Network Advisor 12 2 X on your new 64 bit machine refer to Installation on page 1 3 Restore the server backup from your original 32 bit machine For instructions refer to Restoring data in the Brocade Network Advisor User Manual or online help 4 Install Network Advisor 12 4 1 on the 64 bit Windows server refer to Data Migration on page 39 and migrate your data Migrating data on page 48 Brocade Network Advisor SAN Installation and Migration Guide 45 53 1003747 02 3 46 Pre migration requirements If you are migrating from a Windows server that is no longer supported to a supported Windows server complete the following steps For a list of supported operating system servers refer to Table 2 on page 2 NOTE If you are migrating from a pre 12 0 X release you must first migrate to Network Advisor 12 0 X on your current server refer to Table 9 on page 40 for the release migration path 1 Install Network Advisor 12 2 X on your current machine refer to Installation on page 1 and migrate your data Migrating data on page 48 2 Install Network Advisor 12 4 1 on your new machine refer to Data Migration on page 39 and migrate your data Migrating data on page 48 If you are migrating from a Linux server that is no longer supported to a supported Linux server complete the following
12. DISPLAY Remote_IP_Address 0 0 You may also need to consider a firewall that might block the display to the X Server which listens by default on TCP port 6000 on the remote host To display to a remote system you need to permit the remote display of the X Server by running command xhost IP where IP is the IP address of the Network Advisor server host from the X based desktop of the remote system Make sure you test the DISPLAY definition by running the command xterm from the same shell from which you run install bin A new X terminal window to the destination X Server display should open Additional trial requirements Two versions of the Management application DCFM or Network Advisor cannot reside on the same host unless there are two guest operating systems on the same host Data collected during the Trial cannot be migrated back to the Professional software Once the Enterprise trial period expires you must upgrade to Licensed software Brocade Network Advisor SAN Installation and Migration Guide 47 53 1003747 02 3 Migrating data Migrating data The quickest and simplest method of moving from one package to another is to enter the new license information on the Network Advisor License dialog box To upgrade from a previous release refer to Upgrading the license on page 39 If you have not installed the application refer to Installation on page 1 NOTE If an error occurs while migrating from version 12 3
13. Element Element Manager Manager Manager Ports Element Element Element Manager Manager Manager Admin Element Element Element Manager Manager Manager Router Admin Element Element Element Manager Manager Manager Name Server Element Element Element Manager Manager Manager Fault management Element Element Element Manager Manager Manager Show switch events Yes Yes Yes Show fabric events Yes Yes Yes Syslog registration and forwarding Yes Yes Yes SNMP trap registration and forwarding Yes Yes Yes Trap configuration credentials and customization Yes Yes Yes Event forwarding No Yes Yes Event custom report No Yes Yes Event processing event policies and pseudo events No Yes Yes Common SNMP Trap registration Yes Yes Yes FCIP management FCIP configuration wizard Yes Yes Yes Iperf and IP trace route Yes Yes Yes FCoE management FCoE configuration Yes Yes Yes Migration from DCFM Yes Yes Yes FICON CUP 62 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 TABLE 15 SAN features supported Continued Edition feature support A Feature Professional Professional Plus Enterprise Cascaded FICON configuration wizard No No Yes Cascaded FICON Fabric merge wizard No No Yes PDCM Matrix Element Element Yes Manager Manager Firmware management and supportSave Firmware download Yes Yes Yes Capture SupportSave Yes Yes Yes Flow Vision No Yes Yes Frame monitor N
14. Network Advisor version migration paths Continued Current version Professional version Trial Version Licensed Version Enterprise Professional Enterprise Plus Network Advisor 12 3 X 12 4 0 Professional Yes Yes Yes Yes Network Advisor 12 3 X 12 4 0 Professional Plus Trial No Yes Yes Yes Network Advisor 12 3 X 12 4 0 Professional Plus Licensed No No Yes Yes Network Advisor 12 3 X 12 4 0 Enterprise Trial No Yes No Yes Network Advisor 12 3 X 12 4 0 Enterprise Licensed No No No Yes Network Advisor 12 4 1 Professional Yes Yes Yes Yes Network Advisor 12 4 1 Professional Plus Trial No Yes Yes Yes Network Advisor 12 4 1 Professional Plus Licensed No Yes Yes Yes Network Advisor 12 4 1 Enterprise Trial No Yes Yes Yes Network Advisor 12 4 1 Enterprise Licensed No Yes Yes Yes 1 Network path migration is not supported from Network Advisor 12 2 X on a 32 bit machine to Network Advisor 12 4 1 ona 64 bit machine 2 Local path migration is only supported when you partially uninstall the current version Network path migration whether the current version is fully installed or partially uninstalled is always supported Table 12 shows the migration paths from SMI Agent only For the step by step migration procedures refer to Migrating data on page 48 TABLE 12 SMI Agent only migration paths Current version Professional version Trial version Licensed Version SMI Agent only Professional Enterprise Professi
15. Select Any from the Switch Server IP Configuration Preferred Address list to enable switch and server communication with one of the reachable IP address present in the server By default Any option is selected c Click Next 6 Click Next on the Server Configuration screen 7 SAN with SMI Agent Click Next on the SMI Agent Configuration screen 8 Verify your Server Name on the Server Configuration Summary screen and click Next 9 Click Finish on the Start Server screen 10 Click Yes on the restart server confirmation message 11 Enter your user name and password and click Login The defaults are Administrator and password respectively NOTE Do not enter Domain User_Name in the User ID field for LDAP server authentication 12 Click OK on the Login Banner 34 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Product improvement 2 Product improvement To improve its products Brocade is collecting usage statistics from the field If you agree to participate in the program the Network Advisor server will transmit data back to the secure Brocade web server HTTPS The Brocade web server is hosted in a Brocade network Brocade collects the following usage data e Installation details The version information Such as Major Minor Revision and Patch The Edition Such as Enterprise Professional Plus or Professional The Package such as SAN IP or SAN IP Whether SSL is enabled or not
16. Server Managed Yes JSON Host 555561 Launch in Context LIC client hand TCP Client port used to check if a Client No shaking port Management application client opened using LIC is running on the same host NOTE If this port is in use the application uses the next available port 1 Port does not need to be open in the firewall for Professional edtion 2 The default port number You must use the same port number for all products or hosts managed by the Management server This port is configurable in the Management server however some products and firmware versions do not allow you to configure a port 70 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02
17. Trap and Syslog auto registration e Report content lpconfiguration element does not display all server IP addresses e Trace dump through FTP Client impact e Options dialog box does not display all IP addresses e Firmware import and download dialog box e Firmware import for Fabric OS products e FTP button in Technical Support Repository dialog box e Technical supportSave of Fabric OSand Host products through FTP Brocade Network Advisor SAN Installation and Migration Guide 17 53 1003747 02 2 Configuring Network Advisor a Select an address from the Server IP Configuration list NOTE For Professional software the Server IP Configuration address is set to localhost by default You cannot change this address NOTE For SMI Agent if the Server IP Configuration list contains a duplicate IP address or is empty an error message displays and the configuration wizard closes NOTE If the hostname contains invalid characters the host name does not display in the list Valid characters include alphanumeric and dash characters The IP address is selected by default If Domain Name System DNS is not configured for your network do not select the hostname option from the Server IP Configuration list Selecting the hostname option prevents clients and devices from communicating with the server b Select an address from the Switch Server IP Configuration Preferred Address list e Select Any f
18. Wizard screen click Finish to complete the installation Brocade Network Advisor SAN Installation and Migration Guide 27 53 1003747 02 28 2 Installing the ODBC driver Adding the datasource on Linux systems Before you edit the INI files install Network Advisor refer to Installation on page 1 and make sure the PostgreSQL database is up and running NOTE For RedHat and Oracle Enterprise systems the odbc ini and odbcinst ini files are located in etc For SUSE systems the odbc ini and odbcinst ini files are located in etc unixODBC 1 4 Open the odbc ini file in an editor and enter the datasource information as follows TestDB Description PostgreSQL 9 2 Driver opt PostgreSQL psqlODBC 1lib psqlodbcw so Database dcmdb Servername 172 26 1 54 UserName dcmadmin Password passw0rd Port 5432 Save and close the odbc ini file Open the odbcinst ini file in a text editor and make sure that the driver path information is correct After you install the PostgreSQL ODBC driver the odbcinst ini should automatically update the driver path If the driver path is not updated add the following psqlODBC Description PostgreSQL ODBC driver Driver opt PostgreSQL psqlODBC 1ib psqlodbcw so Save and close the odbcinst ini file Testing the connection on Linux systems To test the connection complete the following steps 1 2 Download and install Open Office Select File gt New
19. X 12 3 X or 12 4 X in the same machine refer to Supported migration paths on page 40 Back up the server using Options gt Server Backup on the 32 bit Windows server Install the same version 12 2 X 12 3 X or 12 4 X on the 64 bit Windows server Select SMC gt Restore to restore the backup on the 32 bit Windows server Install Network Advisor 12 4 1 on the 64 bit Windows server Perform seamless migration to Network Advisor 12 4 1 refer to Migrating data on page 48 If you are migrating from Network Advisor 12 2 X 12 3 X or 12 4 X on a 32 bit Linux server to Network Advisor 12 4 1 on a 64 bit pure Linux server complete the following steps 1 Back up the server for 12 2 X 12 3 X or 12 4 X using Options gt Server Backup on the 32 bit Linux server Install the same version 12 2 X 12 3 X or 12 4 X on the 64 bit pure Linux server Select SMC gt Restore to restore the backup on the 32 bit Linux server Install Network Advisor 12 4 1 on the 64 bit pure Linux server Perform seamless migration to Network Advisor 12 4 1 refer to Migrating data on page 48 If you are migrating from a pre 12 2 X release on a 32 bit Linux server to Network Advisor 12 4 1 on a 64 bit pure Linux server complete the following steps 1 a F WN Install and migrate to Network Advisor 12 2 X 12 3 X or 12 4 X on the 32 bit Linux server refer to Supported migration paths on page 40 Back up the server using Op
20. are not created e Select Network Advisor Server_ P_Address in the Network Advisor directory from the start menu The Network Advisor web client login page displays 2 Click Desktop Client The Network Advisor web start page displays 3 Click the Network Advisor web start link The Log In dialog box displays 4 Loginto another server by entering the IP address to the other server in the Network Address field NOTE The server must be the exact same version edition starting port number and network size as the client NOTE You can remove a server from the Network Address list by selected the IP address and clicking Delete 22 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Accessing the Network Advisor interfaces 2 5 Enter your user name and password The defaults are Administrator and password respectively NOTE Do not enter Domain User_Name in the User ID field for LDAP server authentication 6 Select or clear the Save password check box to choose whether you want the application to remember your password the next time you log in Click Login 8 Click OK on the Login Banner dialog box The Network Advisor application displays Clearing previous versions of the remote client The remote client link in the Start menu does not automatically upgrade when you upgrade the Management application You must clear the previous version from the Java cache To clear the Java cache complet
21. eee xiii Document conventionS 0 00 cece eee ee eee xiv Text formattinE och deta We Ha Bee ete xiv INGUSS nes ramana yds tee secede actin event au oreo dee atin hac tearm ERE xiv Key 1E6MS i sc os ded aed eet aR Aa E RE E E xiv Notice to the reader 0 ccc ee eee XV Additional information 000 cee eee eee eee eee XV Brocade r SOUICES 1 eens XV Other industry reSOUICES 1 eee eee XV Getting technical helps arrsa asasi cee eee xvi Document feedback 1 0 0 00 cc eee eee xvii Installation System requirements anasan na nannan ee ete 1 Server and client operating system requirements 2 Memory host and disk space requirements 4 Operating system cache requirements 2 0005 6 Browser requirementS 0 000 eee eee eee eee 6 Client and server system requirements 000085 7 Downloading the software 0 0 cece eee 7 Pre installation requirements 0 0 00 eee eee eee 8 Additional pre installation requirements for UNIX systems 8 Installing the application 0 0 eee eee 9 Mapping the loopback address to the local host 11 Headless installation 00 00 ccc eee eee eens 11 Additional pre installation requirements for UNIX systems headless installation 0 0 0 0 eee eee 11 Performing a headless installation on Windows and UNIX SYStEMS nsir ee ve es eee eed wee eee eee 12 Troubleshooting the Li
22. following steps to discover whether a default driver already exists and how to reconfigure the driver environment 1 Detect a different Smart Card driver by running the following commands gt cd gt find name pcscd print If the results contain pcscd and it is not located under opt pcsc or etc init d pcscd a different driver exists on the system 2 Make sure the pcscd file on the etc init d directory is linked to opt pcsc pcscctl by running the following commands gt cd etc init d gt ls 1 pcscd lrwxrwxrwx 1 root root 17 Jul 28 01 29 pcscd gt opt pcesc pescctl 32 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 3 Smart Card driver installation 2 If there is an existing pcscd script in this directory you can move and rename this file before you overwrite it gt mv etc init d pcscd etc init d pcscd org Create a soft link using the following command gt In s opt pcesc pescctl etc init d pcscd The existing pcscd org script in this directory implies that a different driver version exists You can compare the existing one with the one under opt pcsc pcscd sbin If the size is different and the existing pcscd script contains the following information you must clean up the driver configuration The example below shows a different pscsd org script and how to do the configuration cleanup The configuration level is 2345 the start priority is 25 and the stop priority
23. gt Database The Database Wizard displays On the Select database screen complete the following steps a Select the Connect to an existing database option b Select ODBC from the list c Click Next On the Set up ODBC connection screen complete the following steps a Click Browse The datasource saved in the odbc ini file is populated in the Datasource dialog box b Select the datasource and click OK on the Datasource dialog box c Click Next Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Installing the ODBC driver 2 5 On the Set up user authentication screen complete the following steps a Enter the database user name in the User name field b Select the Password required check box c Click Test Connection to test the connection The Authentication Password dialog box displays d Enter the database password in the Password field and click OK e Click OK on the Connection Test dialog box For 32 bit Linux systems if an error message file not found while testing the connection displays copy the lib files from the lt postgresSQL path gt lib directory to the usr lib directory For 64 bit Linux systems if an error message cannot open library displays complete the following steps 1 Execute the following command export LD_LIBRARY_PATH opt PostgreSQL 8 4 lib usr 1ib64 opt PostgreSQL p SqlODBC 1ib LD_LIBRARY_PATH 2 Navigate to the Postgres ODBC library default locatio
24. migration paths 40 NOTE Enterprise and Professional Plus editions are not supported on 32 bit servers To migrate Enterprise and Professional Plus editions to a 64 bit server refer to Pre migration requirements when migrating from one server to another on page 44 Direct migration is not supported on pre 12 2 X releases Table 9 shows the migration paths from DCFM and INM Table 10 shows the migration paths from Network Advisor 12 1 X or earlier releases NOTE Network Advisor 11 1 X includes 11 1 0 11 1 1 11 1 2 11 1 3 11 1 4 and 11 1 5 NOTE Network Advisor 11 2 X includes 11 2 0 11 2 1 and 11 2 2 TABLE 9 DCFM and INM release migration path Network Advisor 12 4 1 DCFM 10 4 X DCFM 10 4 X gt Network Advisor 11 1 X gt Network Advisor 12 0 X gt Network Advisor 12 3 X Network Advisor 12 4 1 INM 3 3 INM 3 3 X gt Network Advisor 11 0 X gt Network Advisor 11 1 X gt Network Advisor 12 0 X gt Network Advisor 12 3 X Network Advisor 12 4 1 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Supported migration paths 3 TABLE 10 Pre 12 1 X release migration path Network Advisor 12 4 1 Network Advisor 11 0 X Network Advisor 11 0 X gt Network Advisor 11 1 X gt Network Advisor 12 0 X gt Network Advisor 12 3 X Network Advisor 12 4 1 Network Advisor 11 1 X Network Advisor 11 1 X gt Network Advisor 12 0 X gt Network Advisor 12 3 X Network Advisor 12 4 1 Ne
25. on the Login Banner dialog box The Network Advisor application displays Brocade Network Advisor SAN Installation and Migration Guide 21 53 1003747 02 2 Accessing the Network Advisor interfaces Launching a remote client The remote client link in the Start menu does not automatically upgrade when you upgrade the Management application You must clear the previous version from the Java cache To clear the previous version refer to Clearing previous versions of the remote client on page 23 The remote client requires Oracle JRE For the current supported JRE version for Network Advisor refer to the Release Notes For the website listing patch information go to http www oracle com technetwork java javase downloads index html NOTE For higher performance use a 64 bit JRE NOTE If you are managing more than 9000 SAN ports the client is not supported on 32 bit systems 1 Choose one of the following options e Open a web browser and enter the IP address of the Network Advisor server in the Address bar If the web server port number does not use the default 443 if is SSL Enabled otherwise the default is 80 you must enter the web server port number in addition to the IP address For example P_Address Port_Number If this is the first time you are accessing this version of Network Advisor this creates a start menu shortcut automatically in Network Advisor program directory For Linux systems remote client shortcuts
26. upon system restart If you installed the pcsc directory into the opt directory just create the soft link Otherwise use the name of the new directory in place of opt S u s e gt In s opt pcsc pescctl etc init d pcscd S u s e gt chkconfig add pcscd or redhat gt ln s opt pcsc pescctl etc init d pcscd redhat gt chkconfig add pcscd NOTE Before you enter chkconfig add pcscd you can enter chkconfig list grep pcscd to verify that the pcscd file is already on the list If it already exists you do not need to enter chkconfig add pcscd After you reboot the system you should expect the following links under etc rc2 d etc rc3 d etc rc3 d etc rc4 d and etc rc5 d lrwxrwxrwx 1 root root 15 Jul 28 01 50 S94pcscd gt init d pcscd NOTE For some Linux vendors the Smart Card driver may come with the operating system In this case extra system configuration may be needed For more information refer to Detecting and correcting a default Linux Smart Card driver on page 32 6 Start the pcscd daemon or stop the pcscd daemon To start pcscd type gt opt pesc pescctl start To stop pcscd type gt opt pcesc pescctl stop Brocade Network Advisor SAN Installation and Migration Guide 31 53 1003747 02 2 Smart Card driver installation Installing the Smart Card driver on the remote client 1 Complete steps 1 through 4 in Installing the Smart Card driver on the local client on page 3
27. was deleted None For further information about new features and documentation updates for this release refer to the release notes Brocade Network Advisor SAN Installation and Migration Guide xiii 53 1003747 02 Document conventions This section describes text formatting conventions and important notice formats used in this document Text formatting The narrative text formatting conventions that are used are as follows bold text Identifies command names Identifies the names of user manipulated GUI elements Identifies keywords and operands Identifies text to enter at the GUI or CLI italic text Provides emphasis Identifies variables Identifies paths and Internet addresses Identifies document titles code text Identifies CLI output Identifies command syntax examples For readability command names in the narrative portions of this guide are presented in mixed lettercase for example switchShow In actual examples command lettercase is all lowercase Notes The following notices and statements are used in this manual They are listed below in order of increasing severity of potential hazards NOTE A note provides a tip guidance or advice emphasizes important information or provides a reference to related information Key terms For definitions specific to Brocade and Fibre Channel see the technical glossaries on MyBrocade See Brocade resources on page xv for instructions on accessing MyBrocade For
28. 0 2 Run the following commands to support remote clients Web Start gt cd usr lib gt In s opt pcesc lib libpcsclite so NOTE If a soft link exists on libpcsclite so make sure that the final file is linked to opt pcsc lib libpcsclite so xxx It is recommended that you back up the original Example gt ls 1 libpcsc lrwxrwxrwx 1 root root 20 Aug 4 16 16 libpcsclite so gt libpcesclite so 1 0 0 lrwxrwxrwx 1 root root 20 Jun 4 12 30 libpcsclite so 1 gt libpcesclite so 1 0 0 lrwxrwxrwx 1 root root 34 Aug 5 14 36 libpcsclite so 1 0 0 gt mv libpcsclite so 1 0 0 libpcsclite so 1 0 0 org gt In s opt pesc lib libpcesclite so 1 0 0 libpesclite so 1 0 0 gt ls 1 libpcsc lrwxrwxrwx 1 root root 20 Aug 4 16 16 libpcsclite so gt libpesclite so 1 0 0 lrwxrwxrwx 1 root root 20 Jun 4 12 30 libpcsclite so 1 gt libpcesclite so 1 0 0 lrwxrwxrwx 1 root root 34 Aug 5 14 36 libpcsclite so 1 0 0 gt opt pcsc lib libpcsclite so 1 0 0 rwxr xr x 1 root root 35428 Aug 4 16 17 libpcsclite so 1 0 0 org Detecting and correcting a default Linux Smart Card driver This section applies to the Linux system only Some Linux systems may provide a default Smart Card driver and have their own setup to activate it In this case you must use the driver provided with Network Advisor Otherwise there could be an incompatibility issue between the driver and the native library that could cause a driver detection failure Complete the
29. 0 or earlier to version 12 4 1 it rolls back to the earlier version Migration rollback is not supported if you are performing headless migration NOTE Trial to Professional software migration is not supported NOTE Licensed software to Trial software migration is not supported NOTE Enterprise software to Professional Plus software migration is not supported To migrate data from a previous version complete the following steps 1 Click Next on the Welcome screen 2 Choose one of the following options e If data is detected on your system the Copy Data and Settings from previous releases screen displays To migrate data from the previous version installed automatically detected select Yes from the following location Continue with step 3 e If data is not detected the Copy Data and Settings from previous releases screen displays Complete the following steps a Select Yes from this machine or on network and click Browse to browse to the installation directory b Click Next on the Copy Data and Settings from previous releases screen Continue with step 3 NOTE If you are migrating from a 32 bit server you will need to browse to the shared directory of the 32 bit server on the Copy Data and Settings from previous releases screen NOTE If you are migrating to the same install location as the previous version you will need to browse to the renamed directory on the Copy Data and Settings from previous releases screen
30. 1 2000 Fax 8620 3891 2111 E mail china info brocade com Brocade Network Advisor SAN Installation and Migration Guide Brocade Network Advisor SAN Installation and Migration Guide Brocade Network Advisor SAN Installation and Migration Guide Brocade Network Advisor SAN Installation and Migration Guide Brocade Network Advisor SAN Installation and Migration Guide Brocade Network Advisor SAN Installation and Migration Guide Brocade Network Advisor SAN Installation and Migration Guide Publication Summary of Date number changes 53 1002801 01 New document December 2012 53 1003747 02 Update for 12 1 July 2013 53 1003158 01 Update for July 2014 12 3 0 53 1003374 01 Update for August 2014 12 3 1 53 1003580 01 Update for December 2014 12 3 1 53 1003747 01 Update for April 2015 12 4 0 53 1003747 02 Update for June 2015 12 4 1 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 iii iv Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Contents Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 About This Document Chapter 1 In this chapter si oenina snc cia i Heawh ele sunken aed ix How this document is organized 000 cece eee eee ix Supported hardware and software 0000 c cece eee eee x Fabric OS hardware and software Support X What s new in this document 0 000 eee
31. 2 Fabric OS v6 0 0 or later Fabric OS v6 2 0 xi TABLE 1 Device name Brocade DCX with FS8 18 Blades Fabric OS supported hardware Continued Terminology used in documentation 8 slot Backbone Chassis with Encryption Blade Firmware level required Fabric OS v6 1 1_enc or later Brocade DCX 2 with FX8 24 Blades 8 slot Backbone Chassis with 8 Gbps 12 FC port 10 GbE ports 2 10 GbE ports blade Fabric OS v6 3 1_CEE Brocade DCX 2 with FCoE10 24 Blades 8 slot Backbone Chassis with 10 Gbps 24 port FCoE blade Fabric OS v6 3 1_CEE Brocade DCX 4S 4 slot Backbone Chassis Fabric OS v6 0 0 or later Brocade DCX 4S with FC8 16 FC8 32 and FC8 48 Blades 4 slot Backbone Chassis with 8 Gbps 16 FC port 8 Gbps 32 FC port and 8 Gbps 48 FC port blades Fabric OS v6 2 0 Brocade DCX 4S with FC8 64 Blades Brocade DCX 4S with FR4 18i Blades 4 slot Backbone Chassis with 8 Gbps 64 FC port blades 4 slot Backbone Chassis with 4 Gbps Router Extension blade Fabric OS v6 4 0 Fabric OS v6 2 0 Brocade DCX 4S with FC10 6 Blades 4 slot Backbone Chassis with FC 10 6 ISL Blade Fabric OS v6 2 0 Brocade DCX 4S with FS8 18 Blades Brocade DCX 4S with FX8 24 Blades 4 slot Backbone Chassis with Encryption Blade 4 slot Backbone Chassis with 8 Gbps 12 FC port 10 GbE ports 2 10 GbE ports blade Fabric OS v6 1 1_enc or later Fabric OS v6 3 1_CEE Brocade DCX 4S wit
32. 2 summarizes the required operating system OS for servers and the packages supported by each OS version NOTE It is recommended that you run Network Advisor on a dedicated machine to avoid conflicts with other applications that use the same resources and ports Such as SNMP web server and so on NOTE Enterprise edition and Professional Plus edition are not supported on 32 bit operating systems You must migrate to a 64 bit operating system NOTE If the required operating system is not available a warning message displays during installation TABLE 2 Server operating system requirements Operating system Version Guest OS version Supported packages 4 Windows 2008 Standard edition x86 32 bit 8 Enterprise x86 32 bit 8 1 Enterprise x86 32 bit SAN with SMI Agent Professional SMI Agent only 2008 R2 Data Center Edition x86 64 bit 2008 R2 Standard Edition x86 64 bit 2008 R2 Enterprise Edition x86 64 bit 2012 Data Center Edition x86 64 bit 2012 Standard Edition x86 64 bit 2012 R2 Data Center Edition x86 64 bit 2012 R2 Standard Edition x86 64 bit 8 Enterprise x86 64 bit 8 1 Enterprise x86 64 bit SAN with SMI Agent SMI Agent only Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 TABLE 2 Server operating system requirements Continued Operating system Version Guest OS version Linux RedHat Enterprise 6 4 Advanced x86 32 bit RedHat Enterpr
33. 53 1003747 02 B gt Brocade Network Advisor SAN Installation and Migration Guide Supporting Network Advisor 12 4 1 BROCADE Copyright 2006 2013 Brocade Communications Systems Inc All Rights Reserved Brocade Brocade Assurance the B wing symbol Biglron DCX Fabric OS Fastlron MLX Netlron SAN Health Serverlron Turbolron VCS and VDX are registered trademarks and AnylO Brocade One CloudPlex Effortless Networking ICX NET Health OpenScript and The Effortless Network are trademarks of Brocade Communications Systems Inc in the United States and or in other countries Other brands products or service names mentioned may be trademarks of their respective owners Notice This document is for informational purposes only and does not set forth any warranty expressed or implied concerning any equipment equipment feature or service offered or to be offered by Brocade Brocade reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use This informational document describes features that may not be currently available Contact a Brocade sales office for information on feature and product availability Export of technical data contained in this document may require an export license from the United States government The authors and Brocade Communications Systems Inc shall have no liability or responsibility to any person or entity with respect to any loss c
34. ABLE 3 Client operating system requirements Operating Version system Guest OS version m Windows 7 Enterprise x86 32 bit 8 Enterprise x86 32 bit 8 1 Enterprise x86 32 bit 2008 R2 Data Center Edition x86 64 bit 2008 R2 Standard Edition x86 64 bit 2008 R2 Enterprise Edition x86 64 bit 2012 Data Center Edition x86 64 bit 2012 Standard Edition x86 64 bit 2012 R2 Data Center Edition x86 64 bit 2012 R2 Standard Edition x86 64 bit 7 Enterprise x86 64 bit 8 Enterprise x86 64 bit 8 1 Enterprise x86 64 bit Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 1 System requirements TABLE 3 Operating system Linux Guest VMs Memory host and disk space requirements Client operating system requirements Version RedHat Enterprise 6 4 Advanced x86 32 bit RedHat Enterprise 6 5 Advanced x86 32 bit RedHat Enterprise 6 6 Advanced x86 32 bit RedHat Enterprise 7 0 Advanced x86 32 bit SuSE Enterprise Server 11 3 32 bit SuSE Enterprise Server 12 32 bit Oracle Enterprise 6 4 x86 32 bit Oracle Enterprise 6 5 x86 32 bit Oracle Enterprise 7 0 32 bit SE Ee Guest OS version RedHat Enterprise 6 4 Advanced x86 64 bit RedHat Enterprise 6 5 Advanced x86 64 bit RedHat Enterprise 6 6 Advanced x86 64 bit RedHat Enterprise 7 0 Advanced x86 64 bit SuSE Enterprise Server 11 3 x86 64 bit SuSE Enterprise Server 12 x86
35. Database TFTP Syslog and SNMP port numbers as well as 11 consecutive port numbers from a Starting port On enabling HTTP redirection port 80 is used to redirect the HTTP requests to HTTPS Minimum system requirements will be validated Web Server Port HTTPS 443 Redirect HTTP Requests to HTTPS v Database Port 5432 Starting Port 24600 Syslog Port 514 SNMP Port 162 TFTP Port 69 Change this configuration by selecting Server gt Options gt Server Port from the application Cancel Back Next gt FIGURE 2 Server Configuration screen a Enter a port number in the Web Server Port HTTPS field default is 443 b Enable HTTP redirection to HTTPS by selecting the Redirect HTTP Requests to HTTPS check box When you enable HTTP redirection the server uses port 80 to redirect HTTP requests to HTTPS You can configure the server port settings from the Options dialog box Server Port pane For instructions refer to the Network Advisor User Manual or online help Brocade Network Advisor SAN Installation and Migration Guide 51 53 1003747 02 3 Migrating data Enter a port number in the Database Port field default is 5432 NOTE Do not use a port number below 1024 Enter a port number in the Starting Port field default is 24600 NOTE For Professional software the server requires 11 consecutive free ports beginning with the starting port number NOTE For Trial and Licensed software the se
36. Fabric Manager you must first migrate to DCFM 10 3 X then migrate to Network Advisor 11 1 X then migrate to Network Advisor 12 0 X then migrate to Network Advisor 12 2 X and then migrate to Network Advisor 12 4 1 For more information about migrating from EFCM or Fabric Manager to DCFM 10 3 X contact your customer representative Pre migration requirements Before you install Network Advisor make sure you meet the following pre migration requirements Make sure all system requirements have been met prior to installation For specific system requirements refer to System requirements on page 1 Check for and install the latest Java patches for your operating system For the current supported JRE version for Network Advisor and Web Tools refer to the Release Notes For the website listing patch information go to http www oracle com technetwork java javase downloads index html Fully back up your current Management application data on your management server Close all instances of the application before migrating Install Network Advisor on the same system as your current Management application If you are migrating within the same release or you are migrating from Professional to Licensed software make sure to partially uninstall refer to Uninstallation on page 55 the application Partial data migration is not supported from pre 12 0 0 releases If you are migrating data from a partially uninstalled source complete the f
37. Gbps CNA mode 10 Gbps NIC mode Adapter Software 3 0 0 0 or later Brocade 1867 HBA 16 Gbps Mezzanine HBA Adapter Software 3 0 3 0 or later Brocade 48000 director Director Chassis Brocade 48000 director with FC4 16 FC4 32 and FC4 48 Blades Brocade 48000 director with FR4 18i Blades Director Chassis with 4 Gbps 16 FC port 4 Gbps 32 FC port and 4 Gbps 48 FC port Director Chassis with 4 Gbps router extension blades Fabric OS v5 2 0 or later FC4 48 Fabric OS v5 1 0 or later FR4 18i Brocade 48000 director with FC4 16IP Blades Director Chassis with 4 Gbps 8 FC port and 8 GbE iSCSI blades Fabric OS v5 2 0 or later FC4 16IP Brocade 48000 director with FC10 6 Blades Director Chassis with 10 Gbps 6 port ISL blades Fabric OS v5 3 0 or later FC10 6 Brocade DCX 8 slot Backbone Chassis Fabric OS v6 0 0 or later Brocade DCX with FC8 16 FC8 32 and FC8 48 Blades 8 slot Backbone Chassis with 8 Gbps 16 FC port 8 Gbps 32 FC port and 8 Gbps 48 FC port blades Fabric OS v6 0 0 or later Brocade DCX 2 with FC8 64 Blades 8 slot Backbone Chassis with 8 Gbps 64 FC port blades Fabric OS v6 4 0 Brocade DCX with FR4 18i Blades Brocade DCX with FC10 6 Blades 8 slot Backbone Chassis with 4 Gbps Router Extension blade 8 slot Backbone Chassis with FC 10 6 ISL Blade Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 0
38. Generate reports Yes Yes Yes View reports Yes Yes Yes Performance reports Yes Yes Yes FCR reports Yes Yes Yes SCOM plug in support No Yes Yes Security management Replicate switch policy configuration No Yes Yes SNMP configuration Yes Yes Yes L2 ACL configuration Yes Yes Yes 64 NOTE Only supported on DCB devices Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 TABLE 15 SAN features supported Continued Feature SMI Agent Server Profile Fabric Profile Indication Sub Profile Zone Control Sub Profile Enhanced Zoning and Enhanced Zoning Control Sub Profile FDMI Fabric Device Management Interface Sub Profile Fabrics Virtual Fabrics Sub Profile Topology View Sub Profile FC HBA Fibre Channel Host Bus Adapter Profile Fan Power Supply and Sensor Profiles Inter Fabric Routing FCR Profile Trunking CP Blade Sub Profile CEE Converged Enhanced Ethernet Launch In Context Profile Switch Profile Role Based Authorization CEE ACL Profile N port Virtualizer AG NPIV Profile Profile Registration Sub Profile Object Manager Adapter Sub Profile Fabric Views Sub Profile Physical Package Sub Profile Software Sub Profile Access Points Sub Profile Location Sub Profile Fabric Switch Partitioning Sub Profile FC Initiator Ports Sub Profile Fabric and Host discovery SAN Zoning Switch configuration management Basic configurations through the Element Manager Professional No Yes Edition feature support
39. Save of Fabric OS and Host products through FTP Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Migrating data 3 a Select an address from the Server IP Configuration list NOTE For Professional software the Server IP Configuration address is set to localhost by default You cannot change this address NOTE For SMI Agent if the Server IP Configuration list contains a duplicate IP address or is empty an error message displays and the configuration wizard closes b Select an address from the Switch Server IP Configuration Preferred Address list NOTE If the hostname contains invalid characters the host name does not display in the list Valid characters include alphanumeric and dash characters The IP address is selected by default If DNS is not configured for your network do not select the hostname option from either the Server IP Configuration or Switch Server IP Configuration Preferred Address list Selecting the hostname option prevents clients and devices from communicating with the Server If you select a specific IP address from the Server IP Configuration screen and the selected IP address changes you will not be able to connect to the server To change the IP address refer to Configuring an explicit server IP address on page 34 c Click Next 9 Complete the following steps on the Server Configuration screen Network Advisor requires Web Server
40. You can configure the external FTP server settings from the Options dialog box For instructions refer to the Network Advisor User Manual or online help b Click Next If port 21 or 22 is busy a message displays Click OK to close the message and continue Once the Management application is configured make sure port 21 or 22 is free and restart the Server to start the FTP SCP SFTP service NOTE If you use an FTP SCP SFTP server that is not configured on the same machine as the Management application the Firmware Repository feature will not be available 7 Configure the database password on the Database Administrator Password dcmadmin screen by completing the following steps a Choose one of the following options e To use the default password select Default password This is the default option The default is password e To configure a new password select New password and enter a new password in the Password and Confirm Password fields The password must be between 8 and 15 alphanumeric characters Special characters except single quote are allowed b Click Next 8 Complete the following steps on the Server IP Configuration screen NOTE If the Management server or client has multiple Network Interface Cards and if any of these interfaces are not plugged in you must disable them otherwise the following features do not work properly Server impact e Configuration wizard does not display all IP addresses e
41. are located On the Ready to Install screen click Next Click Finish to complete the installation Adding the data source on Windows systems To add the data source complete the following steps 1 2 Select Start gt Settings gt Control Panel gt Administrative Tools Right click Data Sources ODBC and select Run as administrator The ODBC Data Source Administrator dialog box displays If the ODBC Data Source Administrator dialog box does not display select Start gt Run type swindir Syswow64 odbcad32 exe and press Enter Click the System DSN tab Click Add The Create a New Data Source dialog box displays Select PostgreSQL Unicode Click Finish The PostgreSQL Unicode ODBC Driver psqlODBC Setup dialog box displays Enter a name for the data source in the Datasource field Enter the description of the Network Advisor database in the Description field Enter the name of the Network Advisor database in the Database field Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 10 11 12 13 14 15 16 17 18 Installing the ODBC driver 2 Select enable or disable from the SSL Mode list to specify whether or not to use SSL when connecting to the database Enter the IP address or host name of the Network Advisor server in the Server field Enter the database server port number in the Port Number field Enter the database user name in the User Name field Enter the pas
42. ation paths on page 40 Back up the server using Options gt Server Backup on the 32 bit Linux server Install Network Advisor 12 2 X 12 3 X or 12 4 X on the 64 bit Linux server 32 bit compatible Select SMC gt Restore to restore the backup on the 32 bit Linux server Install Network Advisor 12 4 1 on the 64 bit Linux server 32 bit compatible Perform seamless migration to Network Advisor 12 4 1 refer to Migrating data on page 48 If you are migrating from a pre 12 2 0 release on one server to another server complete the following steps Migrating using this procedure requires that the server versions are the same 32 bit to 32 bit or 64 bit to 64 bit NOTE If you are migrating from a pre 11 3 0 release you must first migrate to Network Advisor 12 0 X on the current server refer to Table 9 on page 40 for the release migration path 1 Install Network Advisor 12 2 X on your new machine refer to Installation on page 1 and migrate your data Migrating data on page 48 using the network path Install Network Advisor 12 4 1 on your new machine refer to Data Migration on page 39 and migrate your data Migrating data on page 48 If you are migrating from a Network Advisor 12 2 X release on a 32 bit server to Network Advisor 12 4 1 on a 64 bit server complete the following steps 1 Back up the Network Advisor 12 2 X server data on your current 32 bit machine For instructions refer to
43. c start Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Chapter Uninstallation 4 In this chapter Uninstalling from Windows Systems 00 02 cee een e ee eee 55 e Uninstalling from Windows systems headless uninstall 56 Uninstalling from UNIX Systems icc 00s 4 eisdeeiaiearadeediteai vane 56 e Uninstalling from UNIX systems headless uninstall 57 This section provides step by step instructions to uninstall Network Advisor and SMI Agent from both Windows and UNIX systems NOTE Network Advisor is installed on a separate directory from your previous version therefore you do not need to uninstall the previous version immediately However you cannot run both versions simultaneously Uninstalling from Windows systems Follow these instructions to uninstall the Network Advisor and SMI Agent from your Windows system 1 Select Start gt Programs gt Network Advisor 12 4 1 gt Uninstall Network Advisor 2 Select one of the following options on the Uninstall Option screen e Partial Uninstall Configuration and performance data is retained to be re used by the new installation This is the default option e Full Uninstall All data is removed Click Uninstall Click Done on the Uninstall Complete screen Brocade Network Advisor SAN Installation and Migration Guide 55 53 1003747 02 4 Uninstalling from Windows systems headless uninstall
44. d hardware Continued Terminology used in documentation 24 port 16 Gbps Edge switch Firmware level required Fabric OS v7 0 1 or later Brocade M6505 embedded switch 24 port 16 Gbps embedded switch Fabric OS v7 2 0 or later Brocade 6510 switch 48 port 16 Gbps switch Fabric OS v7 0 0 or later Brocade 6520 switch 96 port 16 Gbps switch Fabric OS v7 1 0 or later Brocade 6547 embedded switch 48 port 16 Gbps embedded switch Fabric OS v7 2 0 or later Brocade 7500 Extension switch 4 Gbps Router Extension Switch Fabric OS v5 1 0 or later Brocade 7500E Extension switch 4 Gbps Extension Switch Fabric OS v5 1 0 or later FR4 18i Blade 4 Gbps Router Extension blades FX8 24 Blade 8 Gbps Router Extension blades Fabric OS v6 4 0 or later Brocade AP7600 switch 4 Gbps 32 port Switch Fabric OS v6 1 0 or later Brocade 7800 switch Brocade 8000 switch 8 Gbps Extension Switch 8 Gbps 8 FC port 10 GbE 24 DCB port Switch Fabric OS v6 3 0 or later Fabric OS v6 1 2_CEE Brocade 8470 FCoE embedded switch FCoE Embedded Switch Fabric OS v6 3 1_CEE Brocade VA 40FC switch 8 Gbps 40 port Switch Brocade 415 Host Bus Adapter 4 Gbps 1 port HBA Brocade 425 Host Bus Adapter Brocade 815 Host Bus Adapter 4 Gbps 2 port HBA 8 Gbps 1 port HBA Brocade 825 Host Bus Adapter 8 Gbps 2 port HBA Brocade 1860 Fabric Adapter 16 Gbps FC HBA mode 10
45. definitions of SAN specific terms visit the Storage Networking Industry Association online dictionary at http www snia org education dictionary xiv Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Notice to the reader This document may contain references to the trademarks of the following corporations These trademarks are the properties of their respective companies and corporations These references are made for informational purposes only Corporation Referenced trademarks and products Linus Torvalds Linux Microsoft Corporation Windows Windows NT Internet Explorer Netscape Communications Corporation Netscape Red Hat Inc Red Hat Red Hat Network Maximum RPM Linux Undercover Sun Microsystems Inc Sun Solaris Sun Fire Sun Ultra Java Plug in The Open Group UNIX VMware Inc VMware Additional information This section lists additional Brocade and industry specific documentation that you might find helpful Brocade resources To get up to the minute information go to http my brocade com to register at no cost for a user ID and password White papers online demonstrations and data sheets are available through the Brocade website at http www brocade com products solutions products index page For additional Brocade documentation visit the Brocade website http www brocade com Release notes are available on the MyBrocade website Other industry r
46. e Network Advisor SAN Installation and Migration Guide 53 1003747 02 vii viii Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 About This Document In this chapter How this document IS DIBBHIZED pon cc descends coeds ee Vee care ner ed be ix e Supported hardware and Software ccc cece eee eee eee X e Whats NEW IN TIS HOCUMIENM earren E eae deaa re riers ohare eeeees xiii DOCUMENT CONVENTIONS sss rs cee racers re beta ee ee Oe Ta ee RE xiv INS CMI I sortierte edd ard ee coke EEE Buna alse RU mim XV MGM MOMMA isda re che Ree eee PaeEa RGAE ee Re eereRS XV Cetine TeChNiCAl Mlb ccccreescraeg creel ars eee eeer reece ne terres xvi Document TE A ri sat edule reer heen ev ee Ea an E ini ey me a xvii How this document is organized This document is organized to help you find the information that you want as quickly and easily as possible The document contains the following components Chapter 1 Installation provides system and pre installation requirements as well as step by step installation instructions Chapter 2 Network Advisor Configuration provides step by step instructions to configure a fresh Network Advisor installation Chapter 3 Data Migration provides pre migration requirements as well as step by step instructions for migrating data from a previous release of Network Advisor Chapter 4 Uninstallation provides step by step instructi
47. e the following steps 1 Select Start gt Settings gt Control Panel gt Java The Java Control Panel dialog box displays 2 Click View on the General tab The Java Cache Viewer dialog box displays Right click the application and select Delete Click Close on the Java Cache Viewer dialog box Click OK on the Java Control Panel dialog box To create a remote client link in the Start menu refer to Launching a remote client on page 22 Launching the SMC on Windows Open the Server Management Console from the Start menu on the Network Advisor server You can also drag the SMC icon onto your desktop as a short cut Launching the SMC on Linux NOTE The Server Management Console is a graphical user interface and should be launched from the XConsole on Linux systems Double click the SMC icon on your desktop OR 1 On the Network Advisor server go to the following directory Install_Directory bin Brocade Network Advisor SAN Installation and Migration Guide 23 53 1003747 02 2 Accessing the Network Advisor interfaces 2 Type the following at the command line smc OR sh smc Launching the SMIA Configuration Tool 1 Launch the Server Management Console from the Start menu 2 Click Configure SMI Agent The SMIA Configuration Tool Log In dialog box displays 3 Enter your user name and password The defaults are Administrator and password respectively 4 Click Login Launching the SMIA Configuration Tool re
48. eatre SUpport 24 Sh44 68oo Ghali ovadl sei rekat ohare aes 61 Management Server and chent Ports cu cc eee eee eee eae eee 67 Network Advisor packages Table 13 summarizes the packages and available editions for each package TABLE 13 Packages and versions Package Editions SAN with SMI Agent IP e Enterprise trial and licensed e Professional Plus trial and licensed Professional SAN with SMI Agent e Enterprise trial and licensed e Professional Plus trial and licensed Professional IP e Enterprise trial and licensed Professional SMI Agent NOTE Network Advisor clients are not available in the SMI Agent only package Clients are not required when other management tools are used the SMI Agent For a list of the supported scalability limits for Network Advisor by edition refer to Scalability limits on page 60 Brocade Network Advisor SAN Installation and Migration Guide 59 53 1003747 02 A Scalability limits Scalability limits Table 14 summarizes the scalability limits supported for Network Advisor by edition TABLE 14 Supported scalability limits by Network Advisor edition Enterprise edition SAN Professional Plus Professional edition IP Base edition ma edium arge witch Ports SAN Switches and Access Gateways 40 100 400 40 15 SAN Devices 5000 T5000 40000 5000 T000 SAN Fabrics 25 50 TOO 36 2 IP Switches 50 200 1550 Supported 50 50 1200 recommended with per
49. esources For additional resource information visit the Technical Committee T11 website This website provides interface standards for high performance and mass storage applications for Fibre Channel storage management and other applications http www t11 org For information about the Fibre Channel industry visit the Fibre Channel Industry Association website http www fibrechannel org Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 XV Getting technical help Contact your switch support supplier for hardware firmware and software support including product repairs and part ordering To expedite your call have the following information available 1 Management Application Serial Number To obtain the Management application serial number select Help gt License The License dialog box displays 2 General Information Switch model Switch operating system version Software name and software version if applicable Error numbers and messages received supportSave command output Detailed description of the problem including the switch or fabric behavior immediately following the problem and specific questions Description of any troubleshooting steps already performed and the results Serial console and Telnet session logs syslog message logs 3 Switch Serial Number The switch serial number and corresponding bar code are provided on the serial number label as illustrated below
50. ete the following steps 1 Select Start gt Programs gt Accessories right click Command Prompt and select Run as administrator 2 Execute this command install exe i silent DHEADLESS_CONFIG_MODE false 3 From the Install_Home bin directory execute this command configwizard bat DHEADLESS_CONFIGURATION Property_File DHEADLESS true where Property_File is the absolute path of the headless installation property file e For UNIX systems complete the following steps 1 Open a UNIX shell and execute this command sh install bin i silent DHEADLESS_CONFIG_MODE false 2 From the nstall_Home bin directory execute this command sh configwizard DHEADLESS_CONFIGURATION Property_File DHEADLESS true where Property_File is the absolute path of the headless installation property file The application installs in silent mode using default settings To configure the application refer to one of the following sections e If this is a fresh installation refer to Network Advisor Configuration on page 15 e If you are upgrading from a previous version and need to migrate data refer to Data Migration on page 39 12 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Client only installation 1 Troubleshooting the Linux headless installation If you have completed all of the pre Installation requirements and you are still unable to install the applicat
51. expected Upload Failure Data Capture files by 500 KB before the planned periodic purge activity Table 4 summarizes the memory host and disk space requirements for a remote client TABLE 4 Memory Host and Disk space requirements for remote client Resources Required InstalledMemory a 4AB Processor Core Count 2 Disk Space 1GB Table 5 summarizes the minimum system requirements for server plus 1 client installation TABLE 5 Minimum system requirements for server plus 1 client installation Resources Professional Edition Professional Plus or Enterprise Edition Installed Memory 4 GB 32 bit 6 GB 6 GB 64 bit Processor Core Count 2 2 including physical and logical cores Disk Space 10 GB 20 GB Table 6 summarizes the recommended system requirements for server plus 1 client installation TABLE 6 Recommended system requirements for server plus 1 client installation Resources Small Medium Large Installed Memory 16 GB 16 GB 16 GB Processor Core Count 2 4 8 including physical and logical cores Disk Space 20 GB 80 GB 100 GB 1 System requirements Operating system cache requirements It is recommended that you use the System managed size the OS allocates the required cache however if you choose to use a custom size make sure you use the following memory settings for your operating system The virtual memory requirements for Windows system is 1 GB for minimum paging file size and 4 GB for ma
52. formance monitoring on up to 20000 ports MPLS Switches T 10 100 T Not supported VDX Switches 50 T00 400 50 50 Managed Hosts 20 T00 400 T00 20 vCenters T 5 TO 5 T VMS T000 5000 T0000 5000 T000 inlcudes powered down VMs ESX Hosts 200 T000 2000 T000 200 1 The IP switch count includes MPLS and VDX switches NOTE Virtual Fabrics are counted as fabrics when calculating the managed count limits NOTE SMI Agent is not supported on Professional edition NOTE Supported network latency between Network Advisor server and client or server and devices is 100ms 60 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Edition feature support A Edition feature support Table 15 details whether the features are supported in the Professional Plus or Enterprise versions or only through the Element Manager of the device TABLE 15 SAN features supported Feature Professional Professional Plus Enterprise AAA Authentication Authorization and Auditing No Yes Yes Authentication and authorization configuration Access Gateway AG management AG display Yes Yes Yes Support for firmware download supportSave performance statistics and Yes Yes Yes configuration file management Active session management Yes Yes Yes Bottleneck detection Configuration No Yes Yes Statistics No Yes Yes Badge on topology and product tree Yes Yes Yes Show affected host No Yes Yes Ca
53. h FCoE10 24 Blades Brocade DCX 8510 4 4 slot Backbone Chassis with 10 Gbps 24 port FCoE blade 16 Gbps 4 slot Backbone Chassis Fabric OS v6 3 0 or later Fabric OS v7 0 0 or later Brocade DCX 8510 8 2 16 Gbps 8 slot Backbone Chassis Fabric OS v7 0 0 or later Brocade Encryption Switch 8 Gbps Encryption Switch Fabric OS v6 1 1_enc or later FS8 18 Encryption Blade FA4 18 Application Platform Blade Encryption Blade Application Platform Blade FC8 16 Blade FC 8 GB 16 port Blade FC8 32 Blade FC 8 GB 32 port Blade FC8 48 Blade FC 8 GB 48 port Blade FC8 64 Blade FC 8 GB 64 port Blade FC10 6 Blade FC 10 6 ISL Blade FC8 32E blade 8 Gbps 32 port blade Fabric OS v7 0 1 or later FC8 48E blade 8 Gbps 48 port blade Fabric OS v7 0 1 or later FC16 32 Blade 16 Gbps 32 port blade Fabric OS v7 0 0 or later FC16 48 Blade 16 Gbps 48 port blade Fabric OS v7 0 0 or later FCoE10 24 Blade xii 10 Gbps FCoE Port Router Blade Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 TABLE 1 Fabric OS supported hardware Continued Device name FX8 24 Blade 2 Terminology used in documentation Firmware level required 8 Gbps Extension Blade 1 Professional can discover but not manage this device Use the device s Element Manager which can be launched from the Connectivity Map to manage the device This device cannot be used a
54. hentication if you use Server TACACS as an external authentication 69 TFTP UDP File upload download to Product Server Yes product 802 Management application HTTP server TCP Non SSL HTTP 1 1 connector Client Server Yes port if you use secure client server communication You need this port for HTTP redirection 801 Product HTTP server TCP Product non SSL http port for Server Product Yes http and CAL communication if you do not use secure communication to the product Product non SSL http port for Client Product Yes http and CAL communication if you do not use secure communication to the product and you do not use the Management application server proxy 161 SNMP port UDP Default SNMP port Server Product Yes 1622 SNMP Trap port UDP Default SNMP trap port Product Server Yes 3897 LDAP Authentication Server Port UDP LDAP server port for Server LDAP Yes TCP authentication if you use LDAP Server as an external authentication 44312 HTTPS server TCP HTTPS HTTP over SSL server Client Server Yes port if you use secure client server communication 443 HTTPS HTTP over SSL server Server Product Yes port if you use secure communication to the product 443 HTTPS HTTP over SSL server Client Product Yes port if you use secure communication to the product and you do not use the Management application server proxy 443 HTTPS HTTP over SSL server Server vCenter Yes port if you use vCenter Server discovery 4652 SMTP Server port for SSL TCP SMTP Se
55. her you want the application to remember your password the next time you log in Click Login Click OK on the Login Banner dialog box The Network Advisor application displays Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Chapter Network Advisor Configuration 2 In this chapter COG ATEN Network FIVER e ereire cts eaten el tein a ae gel elie elie 15 e Accessing the Network Advisor interfaceS 00000 eee eee eee 21 Syslog troubleshooting 0c ccceecacee ear ede ative ati E rinb nitaka 25 jagtalling mme DDEC ANVET stata st arden aac laa epee a bhedia ieee shee eee ee oa 26 Sinart Card driver MSEE Oe areena ees uo reeeere ee eees 30 e Configuring an explicit server IP address 0 00 e ee eee ee eee 34 Product MPROVEIIB IND ai sarri iiet aE AE REE A ROATE RE welder bi 35 e Configuring remote client access to the database 05 aT Configuring Network Advisor If you have not installed the application refer to Installation on page 1 If you are migrating data refer to Data Migration on page 39 To configure Network Advisor complete the following steps 1 Click Next on the Welcome screen 2 Click No don t any copy data and settings default on the Copy Data and Settings Migration screen and click Next NOTE You cannot migrate data from an earlier release of Network Advisor to 12 4 1 after you complete the 12 4 1 configuration To m
56. igrate data from a previous management application version refer to Data Migration on page 39 Brocade Network Advisor SAN Installation and Migration Guide 15 53 1003747 02 2 Configuring Network Advisor 3 Select one of the following options on the Package screen and click Next e SAN with SMI Agent e SMI Agent Only Go to step 8 NOTE SMI Agent is not supported in a Professional edition configuration NOTE If you choose to install only the SMI Agent the configuration defaults to the SAN Enterprise package When you open the Network Advisor client a License dialog displays where you must enter a SAN Enterprise license key to use the client If you enter a SAN Professional Plus license key you must downgrade your license and restart all services for the changes to take affect For instructions refer to the user manual or online help Select one of the following options on the Installation Type screen and click Next NOTE The DCX and DCX 8510 8 Backbone chassis require the Enterprise edition e Network Advisor Licensed version default Continue with step 5 Requires you to enter a license key during configuration to enable features and configuration e Network Advisor 120 days Trial Go to step 6 Enables you to manage SAN networks from a single interface for 120 days ATTENTION If you choose to install Trial once the trial period ends 120 days you must upgrade to Licensed software e Network Advisor
57. iguring an explicit server IP address Configuring an explicit server IP address If you selected a specific IP address from the Server IP Configuration screen during installation and the selected IP address changes you will not be able to connect to the server To connect to the new IP address you must manually update the IP address information To change the IP address complete the following steps 1 Choose one of the following options e On Windows systems select Start gt Programs gt Network Advisor 12 4 1 gt Network Advisor Configuration e On UNIX systems execute sh Install_Home bin configwizard in terminal Click Next on the Welcome screen Click Yes on the confirmation message Click Next on the FTP Server screen OF 2 IN Complete the following steps on the Server IP Configuration screen a Select an address from the Server IP Configuration list NOTE The host name does not display in the list if it contains invalid characters Valid characters include alphanumeric and dash characters The IP address is selected by default If DNS is not configured for your network do not select the hostname option from the Server IP Configuration list Selecting the hostname option prevents clients and devices from communicating with the server b Select an IP address from the Switch Server IP Configuration Preferred Address list The preferred IP address is used for switch and server communication or
58. ion run the following commands on the host 1 Go to Install_Home the directory containing install bin 2 Execute strace f F v s 1024 o NetworkAdvisorinstall txt install bin 3 Execute rpm qa gt gt system txt 4 Execute ps elf gt gt system txt 5 Execute md5sum install bin gt gt system txt 6 Execute df k gt gt system txt 7 Execute sh c xterm e echo nothing gt gt system txt 2 gt amp 1 8 Execute env gt gt system txt 9 Execute sh c DISPLAY 0 0 xterm e echo nothing gt gt system txt 2 gt amp 1 10 Execute zip support1 zip NetworkAdvisorinstall txt system txt Send the support1 zip file output from the above containing install txt and system txt to Technical Support This file will help Technical Support isolate the issue Collecting supportsave on Windows and Linux To collect server supportsave run the script file located at lt Install_Home gt bin commandsupportsave Once the script file is triggered the server supportsave is collected at the following location lt Install_Home gt support Client only installation You can install a client only application on a machine other than the server without using a web browser by creating a client bundle on the server and then copying and installing that client on another machine Installing the client only application NOTE The client bundle is supported only on a 64 bit OS NOTE To download the client bundle the bro
59. ion by running the xterm command from the same shell from which you run install bin A new X terminal window to the destination X Server display should open Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Installing the application 1 e For Linux OS with the SELinux security policy enabled make sure you complete the following steps 1 Disable the SELinux security policy using the setenforce 0 command 2 Install the application refer to Installing the application on page 9 3 Enable the SELinux security policy using the setenforce 1 command Installing the application Before you install the application make sure your system meets the minimum pre installation requirements refer to Pre installation requirements on page 8 If you are migrating data refer to Data Migration on page 39 NOTE SAN with SMI Agent IP Network Advisoris not supported on 32 bit Windows systems For more information refer to Pre migration requirements on page 43 NOTE On Windows systems you must be an Administrator with Read and Write privileges to install Network Advisor NOTE On UNIX systems you must be the root user to install Network Advisor To install the new application version complete the following steps 1 Choose one of the following options e For Windows systems navigate to the Download_Location Application_Name windows directory right click install exe and select Run as admi
60. is cleared The nominated client requests the server to prepare the data The server compiles the usage data text file into a zip file using the following naming convention UUID_usagedata_file_creataion_timestamp where UUID is the unique identification of the server based on the MAC address Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 11 12 Configuring remote client access to the database 2 When the file is successfully created the client changes the state of the data transfer to Uploading and transmits the data The client transmits the data securely to the Brocade web server using the Apache HTTP Components third party library The client communicates with the Brocade web server using an authorization token When the transfer is complete the client updates the Brocade web server database with the transfer status Success or failure The client also triggers an application event with the following details success or failure source client IP address and source user name Configuring remote client access to the database 1 Open the pg_hba conf file in the Install_Home data databases directory 2 To allow all IPv4 remote connections for all users search for the following text and uncomment the second line IPv4 remote connections Uncomment below line to allow all IPv4 remote users host all all 0 0 0 0 0 md5 3 To allow all IPv6 remote connections for all users search fo
61. is 88 gt more etc init d pcscd bin sh pcscd Starts the pcscd Daemon chkconfig 2345 25 88 Remove the existing pcscd start priority file by deleting the file as SNNpcscd where NN is the start priority For example from the preceding step the file name is S25pcscd gt find etc name S25pcscd exec rm print gt sync sync sync gt reboot After the reboot the new configuration from the opt pcsc pcscctl file should be under the etc rc2 d etc rc3 d etc rc4 d and etc rc5 d directories lrwxrwxrwx 1 root root 15 Jul 28 01 50 S94pcscd gt init d pcscd For the remote client ensure that the Smart Card native library is linked to the one under opt pcsc lib gt ed gt find name libpcsclite so print If the library libpcsclite so exists in multiple locations you must ensure that there is only one library under lib or usr lib and that it is linked to the library on opt pcsc lib correctly For example to find a copy of the library on lib use the following commands gt cd lib gt ls al libpcsclite so If a copy of the library exists either remove it or save it as a backup To find a copy of the library on usr lib use the following commands gt cd usr lib gt ls al libpcsclite so Use this copy for the soft link gt In s opt pcesc lib libpcsclite so usr lib Brocade Network Advisor SAN Installation and Migration Guide 33 53 1003747 02 2 Conf
62. ise 6 5 Advanced x86 32 bit RedHat Enterprise 6 6 Advanced 32 bit RedHat Enterprise 7 0 Advanced x86 32 bit SuSE Enterprise Server 11 3 32 bit SuSE Enterprise Server 12 32 bit Oracle Enterprise 6 4 x86 32 bit Oracle Enterprise 6 5 x86 32 bit Oracle Enterprise 7 0 32 bit System requirements 1 Supported packages SAN with SMI Agent Professional SMI Agent only RedHat Enterprise 6 4 Advanced x86 64 bit RedHat Enterprise 6 5 Advanced x86 64 bit RedHat Enterprise 6 6 Advanced x86 64 bit RedHat Enterprise 7 0 Advanced x86 64 bit SuSE Enterprise Server 11 3 x86 64 bit SuSE Enterprise Server 12 x86 64 bit Oracle Enterprise 6 4 x86 64 bit Oracle Enterprise 6 5 x86 64 bit Oracle Enterprise 7 0 x86 64 bit SS T ee Guest VMs VMware ESXi 5 12 VMware ESXi 5 5 Windows Server 2012 Windows Server 2012 R2 Data Center KVM RH 6 5 1 It is recommended that you run all Network Advisor virtual CPUs on a single physical CPU Supports all server OS versions available for Microsoft Hyper V Hyper V Server 2008 R2 Windows and Linux SAN with SMI Agent SMI Agent only Supports all packages available for Windows and Linux Table 3 summarizes the required OS for clients Network Advisor clients are Supported on 32 bit and 64 bit Windows and Linux systems NOTE If you are managing more than 9000 SAN ports the client is not supported on 32 bit systems T
63. l Click Done on the Uninstall Complete screen 56 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Uninstalling from UNIX systems headless uninstall 4 Uninstalling from UNIX systems headless uninstall If the application was installed using the headless installation complete the following steps to uninstall Network Advisor and SMI Agent from your UNIX server 1 Go to Install_Home Uninstall_Network_Advisor12_4 1 2 Choose one of the following options To partially uninstall Network Advisor configuration and performance data is retained to be re used by the new installation execute Uninstall_Network_Advisor 12_4 1 f lt absolute path of partial uninstall property file gt e To fully uninstall Network Advisor all data is removed execute Uninstall_Network_Advisor 12_4_1 f lt absolute path of full uninstall property file gt When uninstallation is complete an Uninstallation complete message displays You must manually delete the Install_Home silent folder Brocade Network Advisor SAN Installation and Migration Guide 57 53 1003747 02 4 58 Uninstalling from UNIX systems headless uninstall Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Appendix References A In this appendix O Network Advisor packages sec id aiden scat eaa Bi graele bine a eines d das 59 Sealab e UNS cGacaskeck OSes rack Glace ebace eee R ERR ERS 60 Edition T
64. ld default is 5989 if SSL Enabled is selected otherwise the default is 5988 Click Next Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Cross flavor migration 3 11 SAN Enterprise or SMI Agent Select one of the following options on the SAN Network Size screen and click Next NOTE Port count is equal to the total number of switch ports across all fabrics e Small managing up to 2000 switch ports 1 20 domains e Medium managing up to 5000 switch ports 21 60 domains e Large managing up to 15000 switch ports 61 120 domains 12 Enable feature usage data transfer from the application by selecting the Yes want to participate option You can stop participating at any time To view an example of the usage data click View Example Data To stop participating in feature usage data transfer after configuration refer to Product improvement on page 35 13 Verify your configuration information on the Server Configuration Summary screen and click Next 14 Complete the following steps on the Start Server screen a Trial and Licensed only Select the Start SMI Agent check box if necessary b Trial and Licensed only Select the Start SLP check box if necessary c Select the Start Client check box if necessary d Click Finish After all of the services are started the Log In dialog box displays To make changes to the configuration you can re launch the configuration wizard refer
65. le and version number of the document and as much detail as possible about your comment including the topic heading and page number and your suggestions for improvement Brocade Network Advisor SAN Installation and Migration Guide xvii 53 1003747 02 xviii Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Chapter Installation 1 In this chapter BUC Nib RECIPE OES erranera m ey a aria wags Amcaee a laces alan ai e Downloading the SOMWAVE ricsarecsdee ea eb Rae eer ERRA RRR A 7 Preinstallation requirementS ccccecceateleedeireds ta aditeadicand 8 petaling HS Bp AUR cic sis eae ote a dee wd eee ig Go ben eee at Coss des 9 Headless INSIAIIANIONS ce eGdckeCiveuraceusevestaceese EEEE 11 Clentonly instalator siirre iro raiter patar SGes eer thee reed woes 13 System requirements Use the following sections to determine if you have met the requirements for this application e Server and client operating system requirements 0 2000e 2 e Memory host and disk space requirements 2000 cece eee 4 Operating system cache requireMentS 2 5 6 cc cesses cect e cert eesenees 6 e Browser POQUINGINSINES eierne terpei a EEE EE ae keom E ate mobaras 6 e Client and server system requirementS 00000 c eee ee eee eee Fi Brocade Network Advisor SAN Installation and Migration Guide 1 53 1003747 02 1 System requirements Server and client operating system requirements Table
66. list Select the highest version number for the latest GA code For example click Brocade Network Advisor 12 3 x then click Brocade Network Advisor 12 3 1 Brocade GA To download the documentation click Brocade Network Advisor 12 3 1 Manuals and then select the manual you want to download Select one of the following links to download the software e Network Advisor 12 4 1 GA for Windows e Network Advisor 12 4 1 GA for Linux You can also access the release notes and md5 Checksum from this location 1 Pre installation requirements 10 Read the Export Compliance select the certification check box and click Submit 11 Read the Brocade End User License Agreement and click Accept 12 Click Save on the File Download dialog box 13 Browse to the location where you want to save the software and click Save Pre installation requirements Before you install Network Advisor make sure you meet the following requirements Make sure all system requirements have been met prior to installation For specific system requirements refer to System requirements on page 1 If you are running Professional Plus or Enterprise edition on a 32 bit machine you must migrate to a 64 bit machine within your current release then you can migrate to Network Advisor 12 4 To avoid errors close all instances of the application before beginning the installation or uninstallation procedures For UNIX system if you still receive error mes
67. ll Home support Support for all call home centers No Yes Yes SupportSave for Fabric OS switches No Yes Yes Support for appending the last 30 events in a call home event for e mail based No Yes Yes call home centers Certificate management NO Yes Yes COMPASS No Yes Yes Configuration management Configuration repository management No Yes Yes Firmware download Yes Yes Yes Manual backup Yes Yes Yes NOTE Professional only supports one switch at a time Save configuration Yes Yes Yes NOTE Professional only supports one switch at a time Periodic configuration backup and persistence No Yes Yes Replicate switch configuration No Yes Yes Dashboard Yes Yes Yes DCB configuration management Yes Yes Yes DCX backbone chassis discovery and management No No Yes Diagnostic port test No Yes Yes Digital diagnostic Yes Yes Yes Brocade Network Advisor SAN Installation and Migration Guide 61 53 1003747 02 A Edition feature support TABLE 15 SAN features supported Continued Feature Professional Professional Plus Enterprise Encryption Layer 2 FC support Yes Yes Yes Encryption configuration and monitoring Yes Yes Yes Access Gateway Cisco interop support Yes Yes Yes Device decommissioning Yes Yes Yes End device connectivity Yes Yes Yes Collection Views Fabric binding No Yes Yes Fabric Watch Hardware Element
68. log box For instructions refer to the Network Advisor User Manual or online help e Select External FTP SCP SFTP Server to configure an external FTP server You can configure the external FTP server settings from the Options dialog box For instructions refer to the Network Advisor User Manual or online help b Click Next If port 21 or 22 is busy a message displays Click OK to close the message and continue Once the Management application is configured make sure port 21 or 22 is free and restart the Server to start the FTP SCP SFTP service NOTE If you use an FTP SCP SFTP Server which is not configured on the same machine as the Management application the Firmware Repository feature will not be available 8 Complete the following steps on the Server IP Configuration screen NOTE If the Management server or client has multiple Network Interface Cards and if any of these interfaces are not plugged in you must disable them otherwise the following features do not work properly Server impact e Configuration wizard does not display all IP addresses e Trap and Syslog auto registration e Report content lpconfiguration element does not display all server IP addresses e Trace dump through FTP Client impact e Options dialog box does not display all IP addresses e Firmware import and download dialog box e Firmware import for Fabric OS products e FTP button in Technical Support Repository dialog box e Technical support
69. lure occurs while migrating to a different version of Brocade Network Advisor After successful rollback the previous version will be running and the destination version will be uninstalled The destination version failure logs and the source version supportsave will be zipped and stored at the source BNA_HOME support folder in the following format Zip file format Migration_Failure_SupportSave_ lt Time stamp gt zip Migration rollback due to insufficient space When migration rollback fails due to insufficient space you can either increase the disk space and try rollback or cancel the migration rollback The destination version is uninstalled manually if you cancel the migration rollback Use the following commands to retrieve the source version For Windows Install_Home gt bin gt dbsve install Install_Home gt bin gt dbsve start Install_Home gt bin gt service bat dcmsvc install Install_Home gt bin gt service bat dcmsvc start For Windows if SLP is enabled Install_Home gt cimom gt bin gt slpd bat install Install_Home gt cimom gt bin gt slpd bat start For Windows if CIMOM is enabled Install_Home gt bin gt service bat cimomsvce install Install_Home gt bin gt service bat cimomsvc start For Linux Install_Home gt bin gt sh dbsvc start Install_Home gt bin gt sh service dcmsvc start For Linux if SLP is enabled Install_Home gt bin gt sh slpsvc start For Linux if CIMOM is enabled Install_Home gt bin gt sh service cimomsv
70. map the loopback address to the localhost refer to Mapping the loopback address to the local host on page 11 before you configure the application If the localhost is mapped to the loopback address the configuration wizard displays To configure the application refer to one of the following sections e If this is a fresh installation refer to Network Advisor Configuration on page 15 e If you are upgrading from a previous version and need to migrate data refer to Data Migration on page 39 For Linux systems the following lists the folder permissions configured during installation e Install_Home 775 e conf 775 e conf schema folder including sub folders 775 e data 775 e database 700 e db including sub folders 775 e temp 775 e support 777 e All other folders 774 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Headless installation 1 Mapping the loopback address to the local host To map the loopback address to the local host complete the following steps 1 Open the hosts file For Windows the hosts file is located in the WINDOWS system32 drivers etc directory For Linux the hosts file is located in the etc directory 2 Add the following entries For IPV4 machine 127 0 0 1 localhost For IPV6 enabled machine 127 0 0 1 localhost svi localhost 3 Save and close the file To configure the application refer to one of the f
71. mote client The remote client link in the Start menu does not automatically upgrade when you upgrade the Management application You must clear the previous version from the Java cache To clear the previous version refer to Clearing previous versions of the remote client on page 23 The remote client requires Oracle JRE For the current supported JRE version for Network Advisor refer to the Release Notes For the website listing patch information go to http www oracle com technetwork java javase downloads index html 1 Choose one of the following options e Open a web browser and enter the IP address of the Network Advisor server in the Address bar If the web server port number does not use the default 443 if is SSL Enabled otherwise the default is 80 you must enter the web server port number in addition to the IP address For example IP_Address Port_Number If this is the first time you are accessing this version of Network Advisor this creates a start menu shortcut automatically in Network Advisor program directory For Linux systems remote client shortcuts are not created e Select Network Advisor Server_IP_Address in the Network Advisor directory from the start menu The Network Advisor web client login page displays 2 Click Desktop Client The Network Advisor web start page displays 3 Click the SMIA Configuration Tool web start link The SMIA Configuration Tool Log In dialog box displays 4 Enter you
72. n is opt PostgreSQL psqlODBC lib 3 Create a list of missing libraries by executing the following command ldd psqlodbcw so Missing files display as Libodbc so 1 gt not found 4 Find shared libraries with the same name as the missing library by executing the following command find name libodbc so 5 Create a soft link for libodbc so 1 pointing to libodbc so 2 0 0 by executing the following command in s libodbc so 1 libodbc so 2 0 0 f Click Next 6 On the Save and proceed screen click Finish Brocade Network Advisor SAN Installation and Migration Guide 29 53 1003747 02 2 Smart Card driver installation Smart Card driver installation Windows operating systems do not require smart card drivers to be installed separately the driver is bundled with the operating system However you must install a smart card driver for the Linux operating systems You must install both the special USB Chip Smart Card Interface Device USB CCID and the PC SC IFD driver You can download the source code and compile it from one of the following websites e USB CCID ccid 1 3 7 tar bz2 Open Source URL http pcsclite alioth debian org ccid html e Muscle PC SC IFD Driver pcsc lite 1 4 101 tar gz Open Source URL https alioth debian org frs group id 30105 The Encryption Manager Client within Network Advisor provides the binary code on both platforms for installation You must uncompress or untar the file depending on the platfo
73. nistrator e For UNIX systems complete the following steps a On the Management application server navigate to the following directory Download_Location Application_Name UNIX_Platform bin b Type the following at the command line ulimit n 2000 c Type the following at the command line install bin OR sh install bin NOTE On Linux systems if you double click the install bin file select Run Do not select Run in Terminal 2 Click Next on the Introduction screen 3 Read the agreement on the License Agreement screen select accept the terms of the License Agreement and click Next Brocade Network Advisor SAN Installation and Migration Guide 9 53 1003747 02 1 Installing the application 4 Select the usual location for your system application files for example D Program Files Application_Name or opt Application_Name on the Select Install Folder screen and click Next NOTE Do not install to the root directory For example C Windows or root UNIX 5 Review the displayed installation summary on the Pre Installation Summary screen and click Install 6 Make sure the Launch Configuration check box is selected default on the Installation Complete screen and click Done NOTE If a minimum of 10 GB space is not available on your server during installation a warning message displays and installation fails If the localhost is not mapped to the loopback address an error message displays You must
74. nux headless installation 13 Collecting supportsave on Windows and Linux 13 Client only installation annaa 0 0000 ccc eee ee eee 13 Installing the client only application 0 5 13 Chapter 2 Network Advisor Configuration Configuring Network Advisor 0 00 c eee eee 15 Accessing the Network Advisor interfaces 00005 21 Logging into ASErVer 1 kee 21 Launching a remote Client 0 0 0 e eee eee eee 22 Clearing previous versions of the remote client 23 Launching the SMC on Windows 00200e eee eens 23 Launching the SMC on Linux 0 0 e eee eee eee 23 Launching the SMIA Configuration Tool 005 24 Launching the SMIA Configuration Tool remote client 24 Syslog troubleshooting anaana eee ees 25 Finding the proceSS 0 cece etc r nnen 25 Stopping the proceSS 2 0 c ee ees 25 Installing the ODBC driver 0 0 0 0 cee eee 26 Installing the ODBC driver on Windows systems 26 Installing the ODBC driver on Linux systemsS 27 Smart Card driver installation 0 000 c eee eee eee 30 Installing the Smart Card driver on the local client 30 Installing the Smart Card driver on the remote client 32 Detecting and correcting a default Linux Smart Card driver 32 Configuring an explicit server IP address 00000 34 Product improvement
75. o Yes Yes HBA management HBA management Yes Yes Yes VM management Yes Yes Yes Driver DIOS management No Yes Yes Fabric assigned WWN No Yes Yes HBA Server and Storage port mapping No Yes Yes High Integrity Fabric No Yes Yes IPv6 Server Switch support Yes Yes Yes iSCSI discovery Yes Yes Yes Layer 2 trace route No Yes Yes License No Yes Yes MAPS management No Yes Yes Meta SAN No Yes Yes Routing configuration Domain ID configuration Name Server Yes Yes Yes Open Trunking Support Display trunks on the topology Yes Yes Yes Display trunks properties Yes Yes Yes Display marching ants Yes Yes Yes Display connections properties Yes Yes Yes Brocade Network Advisor SAN Installation and Migration Guide 63 53 1003747 02 A Edition feature support TABLE 15 SAN features supported Continued Feature Professional Professional Plus Enterprise Performance management SNMP monitoring Real Time Performance collection display and reports Yes Yes Yes Historical Performance collection display and reports No Yes Yes Thresholds No Yes Yes Top talkers Supported on SAN switches and Access Gateway No Yes Yes Marching ants No Yes Yes Data aging No Yes Yes End to End monitors No Yes Yes Policy Monitor Yes Yes Yes Port Administration Element Element Element Manager Manager Manager Port Fencing No Yes Yes Port group configuration No No Yes REST API No Yes Yes Reports Yes Yes Yes
76. ollowing sections e If this is a fresh installation refer to Network Advisor Configuration on page 15 e If you are upgrading from a previous version and need to migrate data refer to Data Migration on page 39 Headless installation Headless installation also known as silent mode installation is fully supported on all platforms Once initiated the headless installation requires minimal user interaction and runs based on the default values provided Headless installation performs the actual installation however you must use the Configuration wizard in graphical user interface mode to copy data and settings configure the FTP or SCP server configure IP and configure server ports Before you install Network Advisor make sure you meet the following requirements Make sure all system requirements have been met prior to installation For specific system requirements refer to System requirements on page 1 Additional pre installation requirements for UNIX systems headless installation An X Server display is required even when performing a headless installation to run the initial configuration Before you install Network Advisor complete the following e Make sure that an X Server is available for display and is configured to permit X Client applications to display from the host on which they are installing the Network Advisor server typically this simply requires that the system console be present and running wi
77. ollowing steps 1 Re install your current Network Advisor version on the same machine and migrate the partially uninstalled data If your current release is pre 11 3 X you must migrate to Network Advisor 11 3 0 or later Refer to Table 9 on page 40 for the release migration path 2 Install Network Advisor 12 1 refer to Installation on page 1 on the same machine and migrate your data refer to Migrating data on page 48 Brocade Network Advisor SAN Installation and Migration Guide 43 53 1003747 02 44 3 Pre migration requirements Pre migration requirements when migrating from one server to another If you are migrating from Network Advisor 12 2 X 12 3 X or 12 4 X on a 32 bit Windows server to Network Advisor 12 4 1 on a 64 bit Windows server complete the following steps 1 Back up the server for 12 2 X 12 3 X or 12 4 X using Options gt Server Backup on the 32 bit Windows server Install Network Advisor 12 2 X 12 3 X or 12 4 X on the 64 bit Windows server Select SMC gt Restore to restore the backup on the 32 bit Windows server Install Network Advisor 12 4 1 on the 64 bit Windows server Perform seamless migration to Network Advisor 12 4 1 refer to Migrating data on page 48 If you are migrating from a pre 12 2 X release on a 32 bit Windows server to Network Advisor 12 4 1 on a 64 bit Windows server complete the following steps 1 ao F WN Install and migrate to Network Advisor 12 2
78. onal Enterprise Plus Plus Network Advisor 12 2 X 12 3 X 12 4 X No No No No No Yes SMI Agent only DCFM migration paths NOTE Before you migrate from DCFM to Network Advisor 11 0 X 11 1 0 11 1 1 or 11 1 2 you must reset your DCFM password back to the default password You cannot migrate directly from DCFM 10 0 X DCFM 10 1 X or DCFM 10 3 X to Network Advisor 12 4 1 You must first migrate to DCFM 10 4 X then migrate to Network Advisor 11 1 X then migrate to Network Advisor 12 0 X then migrate to Network Advisor 12 2 X and then migrate to Network Advisor 12 4 1 To migrate from DCFM 10 0 X DCFM 10 1 X or DCFM 10 3 X to DCFM 10 4 X contact your customer representative To migrate from DCFM 10 4 X to Network Advisor 11 1 X refer to the Network Advisor Migration Guide for Network Advisor 11 1 X 42 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Pre migration requirements 3 INM migration paths You cannot migrate directly from INM to Network Advisor 12 4 1 You must first migrate to Network Advisor 11 0 X then migrate to Network Advisor 11 1 X then migrate to Network Advisor 12 0 X then migrate Network Advisor to 12 2 X and then migrate to Network Advisor 12 4 1 To migrate from INM to Network Advisor 11 1 X contact your customer representative EFCM and Fabric Manager migration paths You cannot migrate directly from EFCM or Fabric Manager to Network Advisor 12 4 1 To migrate from EFCM or
79. ons for performing a partial or full uninstall of Network Advisor Appendix A References provides the following information for quick lookup Network Advisor packages Edition feature support Management server and client ports Scalability limits Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Supported hardware and software In those instances in which procedures or parts of procedures documented here apply to some devices but not to others this guide identifies exactly which devices are supported and which are not Although many different software and hardware configurations are tested and supported by Brocade Communications Systems Inc for Network Advisor 12 1 X documenting all possible configurations and scenarios is beyond the scope of this document Fabric OS hardware and software support The following firmware platforms are supported by this release of Network Advisor 12 1 X e Fabric OS 5 0 or later in a pure Fabric OS fabric e Fabric OS 6 0 or later in a mixed fabric NOTE Discovery of a Secure Fabric OS fabric in strict mode is not supported The hardware platforms in the following table are supported by this release of Network Advisor 12 1 X TABLE 1 Fabric OS supported hardware Device name Terminology used in documentation Firmware level required Brocade 200E switch 16 port 4 Gbps FC Switch Brocade 300 switch 24
80. ort a zone database No Yes Yes 66 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Management server and client ports A Management server and client ports The Management application has two parts the Server and the Client The Server is installed on one machine and stores device related information it does not have a user interface To view information through a user interface you must log in to the Server through a Client The Server and Clients may reside on the same machine or on separate machines If you are running Professional the server and the client must be on the same machine In some cases a network may utilize virtual private network VPN or firewall technology which can prohibit communication between Products and the Servers or Clients In other words a Server or Client can find a Product appear to log in but is immediately logged out because the Product cannot reach the Server or Client To resolve this issue check to determine if the ports in the table below need to be opened up in the firewall NOTE Professional edition does not support remote clients Table 16 lists the default port numbers and whether or not it needs to be opened up in the firewall and includes the following information e Port Number The port at the destination end of the communication path e Ports The name of the port e Transport The transport type TCP or UDP e Description A brief descri
81. ost liability or damages arising from the information contained in this book or the computer programs that accompany it The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements To find out which open source software is included in Brocade products view the licensing terms applicable to the open source software and obtain a copy of the programming source code please visit http www brocade com support oscd Brocade Communications Systems Incorporated Corporate and Latin American Headquarters Brocade Communications Systems Inc 130 Holger Way San Jose CA 95134 Tel 1 408 333 8000 Fax 1 408 333 8101 E mail info brocade com European Headquarters Brocade Communications Switzerland S rl Centre Swissair Tour B 4 me tage 29 Route de l A roport Case Postale 105 CH 1215 Gen ve 15 Switzerland Tel 41 22 799 5640 Fax 41 22 799 5641 E mail emea info brocade com Document History Title Asia Pacific Headquarters Brocade Communications Systems China HK Ltd No 1 Guanghua Road Chao Yang District Units 2718 and 2818 Beijing 100020 China Tel 8610 6588 8888 Fax 8610 6588 9999 E mail china info brocade com Asia Pacific Headquarters Brocade Communications Systems Co Ltd Shenzhen WFOE Citic Plaza No 233 Tian He Road North Unit 1308 13th Floor Guangzhou China Tel 8620 389
82. ou option Click OK to save your selection and close the Options dialog box Data transfer If you agree to participate in the program these are the actions that occur on the client and server 1 10 You log in to the Network Advisor client The main window displays The application automatically schedules a timer The timer is configured with an initial delay of 5 minutes and an interval of 24 hours Once scheduled the client triggers the scheduled data transfer The client checks the reachability of the Brocade web server for the data transfer to make sure that the client workstation has HTTP connectivity If the Brocade web server is reachable the client schedules the timer The client triggers the schedule to run in 5 minutes and then every 24 hours thereafter When the scheduled timer runs the client requests the server to transfer the usage data The server determines the availability of the data based on the following details e Last transfer timestamp must be greater than 24 hours to avoid frequent data uploads e Data must be available for transfer Data availability is determined by the difference between the last data transfer and the current data The client requests a data transfer If data is available the server nominates the client to transfer data Once nominated any further upload requests are denied NOTE If the nominated client s session is ended or stuck the session is invalidated and the state
83. ow UDP Receives sFlow data from Product Server Yes products if you are monitoring with sFlow 246001 2 JBoss remoting connector port TCP Use for service location Uses Client Server Yes SSL for privacy 2460112 JBoss Transaction Services Recovery TCP Not used remotely Server Yes Manager port 2460212 JBoss Transaction Status Manager port TCP Not used remotely Server Yes 246031 2 HornetQ Netty port TCP Use for JMS Java Message Client Server Yes Service async messages from server to client Uses SSL for privacy 246041 JMX remoting connector port TCP Management console port for Client Server Yes native connector JMX 2460512 JBoss https management port TCP Management console port for Client Server Yes TCP HTTPS based management 246061 Fault Management CIM Indication TCP Used for HBA management Managed Host Yes Listener Port Server 2460712 HCM Proxy CIM Indication Listener port TCP Used for HBA management Managed Host Yes Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Server 69 A Management server and client ports TABLE 16 Port usage and firewall requirements Continued Port Number Ports Transport Description Communication Path Open in Firewall 24608 Reserved for future use TCP Not used Client Server No 24609 Reserved for future use TCP Not used Client Server No 24610 Reserved for future use TCP Not used Client Server No 34568 HCM Agent discovery port TCP Used for HBA management via
84. port 8 Gbps FC Switch Fabric OS v6 1 0 or later Brocade 4012 switch Embedded 12 port 4 Gbps FC Switch Brocade 4016 switch Embedded 16 port 4 Gbps FC Switch Brocade 4018 switch Embedded 18 port 4 Gbps FC Switch Brocade 4020 switch Embedded 20 port 4 Gbps FC Switch Brocade 4024 switch Embedded 24 port 4 Gbps FC Switch Fabric OS v5 3 1 or later Brocade 4100 switch 32 port 4 Gbps FC Switch Brocade 4900 switch 64 port 4 Gbps FC Switch Fabric OS v5 2 0 or later Brocade 5000 switch 32 port 4 Gbps FC Interop Switch Fabric OS v5 2 1 or later Brocade 5100 switch 40 port 8 Gbps FC Switch Fabric OS v6 1 0 or later Brocade 5300 switch 80 port 8 Gbps FC Switch Fabric OS v6 1 0 or later Brocade 5410 embedded switch Embedded 12 port 8 Gbps Switch Fabric OS v6 1 0 or later Brocade 5424 embedded switch Embedded 24 port 8 Gbps Switch Fabric OS v6 1 0 or later Brocade 5431 embedded switch Embedded 16 port 8 Gbps Stackable Switch Fabric OS v7 2 0 or later Brocade 5450 embedded switch Embedded 16 port 8 Gbps Switch Fabric OS v6 2 0 or later Brocade 5460 embedded switch Embedded 24 port 8 Gbps Switch Fabric OS v6 1 0_emb or later Brocade 5470 embedded switch Embedded 24 port 8 Gbps Switch Fabric OS v6 1 0 or later Brocade 5480 embedded switch Embedded 24 port 8 Gbps Switch Fabric OS v6 1 0 or later x Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 TABLE 1 Device name Brocade 6505 switch Fabric OS supporte
85. ption of the port e Communication Path The source to destination values Client and Server refer to the Management application client and server unless stated otherwise Product refers to the Fabric OS Network OS or IronWare OS devices e Open in Firewall Whether the port needs to be open in the firewall NOTE For bi directional protocols you must open the firewall port bi directionally TABLE 16 Port usage and firewall requirements Port Number Ports Transport Description Communication Path Open in Firewall 201 FTP Port Control TCP FTP Control port for internal Client Server Yes FTP server Product Server 211 FTP Port Data TCP FTP Data port for internal Client Server Yes FTP server Product Server 22 SSH or SCP or SFTP TCP Secure telnet and secure Server Product Yes upload and download to Client Product product Product Server 23 Telnet TCP Telnet port from server client Server Product Yes to product Client Product 25 SMTP Server port TCP SMTP Server port for e mail Server SMTP Yes communication if you use Server e mail notifications without SSL Brocade Network Advisor SAN Installation and Migration Guide 67 53 1003747 02 A Management server and client ports TABLE 16 Port usage and firewall requirements Continued PortNumber Ports Transport Description Communication Path Open in Firewall 49 TACACS Authentication port TCP TACACS server port for Server TACACS Yes aut
86. r License dialog box The following tables list the available upgrade paths TABLE 8 SAN upgrade paths Current software release To software release SAN Professional SAN Professional Plus or Licensed version SAN Enterprise Trial or Licensed version SAN Professional Plus Licensed version SAN Enterprise Licensed version SAN Enterprise Trial SAN Enterprise Licensed version 1 Select Help gt License The Network Advisor License dialog box displays 2 Browse to the license file xml and click Update Click OK on the Network Advisor License dialog box 4 Click OK on the message The Client closes after updating the license successfully Restart the Server from the Server Management Console for the changes to take effect 5 Open the application double click the desktop icon or open from the Start menu The Log In dialog box displays 6 Enter your user name and password The defaults are Administrator and password respectively If you migrated from a previous release your user name and password do not change Brocade Network Advisor SAN Installation and Migration Guide 39 53 1003747 02 3 Supported migration paths NOTE Do not enter Domain User_Name in the User ID field for LDAP server authentication 7 Select or clear the Save password check box to choose whether you want the application to remember your password the next time you log in 8 Click Login Click OK on the Network Advisor Login Banner Supported
87. r the following text and uncomment the second line IPv6 remote connections Uncomment below line to allow all IPv6 remote users host all all 0 0 md5 4 Toallow access to a specific IPv4 address search for the following text and uncomment the second line Uncomment below line and provide IPV4 address to allow specific IPv4 remote user host all all lt IPV4 address gt 32 md5 5 To allow access to a specific IPv6 address search for the following text and uncomment the second line Uncomment below line and provide IPV6 address to allow specific IPv6 remote user host all all lt IPV6 address gt 128 md5 6 Save and close the file Brocade Network Advisor SAN Installation and Migration Guide 37 53 1003747 02 38 2 Configuring remote client access to the database Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Chapter Data Migration 3 In this chapter Uae Fae MUR Mit SN a acca id eatin oh Bd mia tied Gell Ha ad Si egal dad wih ed carne 39 Supported MISFANON PANISsccosaveseava seer eE seeder ceaeeeReeene 40 Premigation regure MS raserna dipatri een nt riir aipa 43 SME A RANA a E Wee ad oh a el nied ea 48 Gross lavor MIER aO ericeti krenk EE REESTR EEEE tee eee eee 53 Miron POURAGK pocis prere rnare e na eRe eke ha 54 Upgrading the license The quickest and simplest method of moving from one package to another is to enter the new license information on the Network Adviso
88. r user name and password The defaults are Administrator and password respectively Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Syslog troubleshooting 2 5 Select or clear the Save password check box to choose whether you want the application to remember your password the next time you log in 6 Click Login The SMIA Configuration Tool displays Syslog troubleshooting If the default syslog port number is already in use you will not receive any syslog messages from the device Use one of the following procedures depending on your operating system to determine which process is running on the syslog port and to stop the process Finding the process 1 Open a command window 2 Choose one of the following options On Linux systems type netstat nap grep 514 and press Enter The process running on port 514 displays Example output UDP O O ffff 127 0 0 1 514 27397 On Windows systems type netstat anb find i 514 and press Enter The process running on port 514 displays Example output UDP 127 0 0 1 514 3328 Stopping the process Choose one of the following options On Linux systems type kill 9 ProcessID where ProcessID is the ID of the process you want to stop and press Enter For example kill 9 27397 On Windows systems type taskkill F PID ProcessID where ProcessID is the ID of the process you want to stop and press Enter
89. rm The procedures for the local client and the remote client configurations follow The thirdparty pscs lite 1 4 101 linux x86 tar gz file can be found on the Network Advisor software download Installing the Smart Card driver on the local client 1 Verify that the opt directory exists If the opt directory does not exist create an opt directory If you want to install the driver in a different directory create that directory Otherwise skip this step gt su gt mkdir opt 2 Copy the appropriate pscs file for your platform Linux from the DVD and rename the file as pcsc lite 1 4 101 linux x86 tar gz file 3 Login as the superuser to untar the pcsc lite 1 4 101 linux x86 tar gz file su cd opt gunzip pcsc lite 1 4 101 linux x86 tar gz gt tar xvf pcesc lite 1 4 101 linux x86 tar After the pcsc_lite_1 4 101 tar file is extracted the necessary binary library and smart card drivers are stored in the opt pcsc directory VV Vv 4 Ifyou installed a pcsc directory into a location other than opt modify the pcscctl script to change opt to the directory you specified in step 1 gt cd lt new_dir gt gt vi pesectl Search for opt and change it to the name of the new directory 30 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Smart Card driver installation 2 5 Create a soft link into the system directory This is to support the automatic restart of the pcscd daemon
90. rom the Switch Server IP Configuration Preferred Address list to enable switch and server communication with one of the reachable IP address present in the server By default Any option is selected or e Select an IP address from the Switch Server IP Configuration Preferred Address list The preferred IP address is used for switch and server communication If the selected IP address changes you will be unable to connect to the server To change the IP address after configuration refer to Configuring an explicit server IP address on page 34 c Click Next 9 Complete the following steps on the Server Configuration screen Figure 1 Network Advisor requires Web Server Database TFTP Syslog and SNMP port numbers as well as 11 consecutive port numbers from a Starting port On enabling HTTP redirection port 80 is used to redirect the HTTP requests to HTTPS Minimum system requirements will be validated Web Server Port HTTPS 443 Redirect HTTP Requests to HTTPS y Database Port 5432 Starting Port 24600 Syslog Port b SNMP Port he2 TFTP Port es Change this configuration by selecting Server gt Options gt Server Port from the application Cancel Back Next gt FIGURE 1 Server Configuration screen Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Configuring Network Advisor 2 a Enter a port number in the Web Server Port HTTPS field defa
91. rrent machine and migrate your data refer to Migrating data on page 48 2 Back up the server data on your current machine For instructions refer to Configuring backup in the Brocade Network Advisor User Manual or online help Install Network Advisor 12 4 1 refer to Installation on page 1 on the new machine 4 Restore the server backup from your original machine For instructions refer to Restoring data in the Brocade Network Advisor User Manual or online help Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Pre migration requirements 3 Additional pre migration requirements on UNIX systems 1 Make sure that the current application services are running Go to Install_Home bin 2 Execute smc or sh smc 3 Click the Services tab The tab lists the DCFM services 4 Click Start if necessary Make sure that an X Server is available for display and is configured to permit X Client applications to display from the host on which they are installing the Network Advisor Server typically this simply requires that the systems console be present and running witha logged in user on the X Server based desktop session such as KDE GNOME and so on Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid value for example to display to the local console export DISPLAY 0 0 or to display to a remote system that has an X Server running export
92. rver port for e mail Server SMTP Yes communication if you use Server e mail notifications with SSL 5142 Syslog Port UDP Default Syslog Port Product Server Yes Managed Host Server 68 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Management server and client ports A TABLE 16 Port usage and firewall requirements Continued PortNumber Ports Transport Description Communication Path Open in Firewall 6367 LDAP Authentication SSL port TCP LDAP server port for Server LDAP Yes authentication if you use LDAP Server as an external authentication and SSL is enabled 1812 RADIUS Authentication Server Port UDP RADIUS server port for Server RADIUS Yes authentication if you use Server RADIUS as an external authentication 1813 RADIUS Accounting Server Port UDP RADIUS server port for Server RADIUS Yes accounting if you use RADIUS Server as an external authentication 5432 Database port TCP Port used by database if you Remote ODBC Yes access the database remotely Database from a third party application 5988 SMI Server port TCP SMI server port on the SMI Client Server Yes Management application and the CIM SMI port on HBAs if you use SMI Agent without SSL Server Managed Yes Host 59891 2 SMI Server port with SSL enabled TCP SMI Agent port on the SMI Agent Server Yes Management application and Client the CIM SMI port on HBAs if you use SMI Agent with SSL Server Managed Yes Host 63432 sFl
93. rver requires 11 consecutive free ports beginning with the starting port number Enter a port number in the Syslog Port field default is 514 NOTE If the default syslog port number is already in use you will not receive any syslog messages from the device To find and stop the process currently running on the default Syslog port number refer to Syslog troubleshooting on page 25 Enter a port number in the SNMP Port field default is 162 Enter a port number in the TFTP Port field default is 69 Click Next If you enter a syslog port number already in use a message displays Click No on the message to remain on the Server Configuration screen and edit the syslog port number Click Yes to close the message and continue with step 10 If you enter a port number already in use a warning displays next to the associated port number field Edit that port number and click Next If you are configuring Professional software go to step 12 10 SAN with SMI Agent Complete the following steps on the SMI Agent Configuration screen a b 52 Enable the SMI Agent by selecting the Enable SMI Agent check box Enable the SLP by selecting the Enable SLP check box if necessary Only enabled after you select the Enable SMI Agent check box Enable the SSL by selecting the Enable SSL check box if necessary Only enabled after you select the Enable SMI Agent check box Enter the SMI Agent port number in the SMI Agent Port fie
94. s a Seed switch 2 Professional Plus Trial and Licensed version can discover but not manage this device Use the device s Element Manager which can be launched from the Connectivity Map to manage the device This device cannot be used as a Seed switch 3 Only supported on the DCX 8510 4 and DCX 8510 8 chassis What s new in this document The following changes have been made since this document was last released e Information that was added Documented OS cache requriements refer to Operating system cache requirements on page 6 Documented Linux 64 bit troubleshooting refer to Testing the connection on Linux systems on page 28 Documented unsupported migration work arounds refer to Pre migration requirements on page 43 e Information that was changed Updated server and client operating system details refer to Server and client operating system requirements on page 2 Updated the Java Plug ins Browser requirements on page 6 Updated the number of clients allowed Client and server system requirements on page 7 Updated configuration procedure Configuring Network Advisor on page 15 Updated accessing the interface procedures Accessing the Network Advisor interfaces on page 21 Updated Linux ODBC driver procedure Installing the ODBC driver on Linux systems on page 27 Updated migration paths Supported migration paths on page 40 e Information that
95. sages after closing the application enter the following commands ps ef grep i to list the process IDs kill 9 Process_ID where Process_ID is any Management application process Additional pre installation requirements for UNIX systems Make sure that an X Server is available for display and is configured to permit X Client applications to display from the host on which they are installing the Network Advisor server typically this simply requires that the systems console be present and running with a logged in user on the X Server based desktop session such as KDE GNOME and so on If this is a headless unit with no console refer to Additional pre installation requirements for UNIX systems headless installation on page 11 Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid value for example to display to the local console export DISPLAY 0 0 orto display toa remote system that has an X Server running export DISPLAY Remote_ IP_address 0 0 You may also need to consider a firewall that might block the display to the X Server which listens by default on TCP port 6000 on the remote host To display to a remote system you need to permit the remote display of the X Server by running the xhost IP command where IP is the IP address of the Network Advisor server host from the X based desktop of the remote system Make sure you test the DISPLAY definit
96. server system requirements In the Professional edition a single server supports a single client which must be a local client only In Professional Plus and Enterprise editions a single server supports a maximum of 25 clients which can be local on a 64 bit server or remote on 32 bit and 64 bit servers In Professional Plus and Enterprise editions a single server supports a maximum of 25 clients which can be local or remote on 64 bit servers To Support more than 8 clients you must make the following changes to your configuration Increase the server memory size You can configure the server memory size from the Options dialog box Memory Allocations pane For instructions refer to the Network Advisor User Manual or online help Increase the PostgreSQL database shared buffers memory allocation to 1024 MB by editing the Install_Home data databases postgresal conf file Downloading the software You can download the software and documentation from the MyBrocade website Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 1 ona F Ww Go to the MyBrocade website http my brocade com Enter your user ID and password If you do not already have a MyBrocade account you can create one Select MyBrocade from the Take me to list if necessary Click LOG IN Click downloads on the main page Select Management Software from the Download by list Click Brocade Network Advisor in the Product Name
97. ssing the Network Advisor interfaces 2 15 Enter your user name and password The defaults are Administrator and password respectively NOTE Do not enter Domain User_Name in the User ID field for LDAP server authentication 16 Click Login 17 Click OK on the Network Advisor Login Banner Accessing the Network Advisor interfaces Use the following procedures to access Network Advisor from the server and client as well as to access the Server Management Console and the SMI Agent Configuration Tool Logging into a server You must log into a server to monitor your network NOTE You must have an established user account on the server to log in 1 Double click the desktop icon or open the application from the Start menu The Log In dialog box displays 2 Loginto another server by entering the IP address to the other server in the Network Address field NOTE The server must be the exact same version edition starting port number and network size as the client NOTE You can remove a server from the Network Address list by selecting the IP address and clicking Delete 3 Enter your user name and password The defaults are Administrator and password respectively NOTE Do not enter Domain User_Name in the User ID field for LDAP server authentication 4 Select or clear the Save password check box to choose whether you want the application to remember your password the next time you log in Click Login 6 Click OK
98. steps For a list of supported operating system servers refer to Table 2 on page 2 NOTE If you are migrating from a pre 12 0 X release you must first migrate to Network Advisor 12 0 X on your current server refer to Table 9 on page 40 for the release migration path 1 Install Network Advisor 12 2 X on your current machine refer to Installation on page 1 and migrate your data Migrating data on page 48 2 Back up the server data on your current machine For instructions refer to Configuring backup in the Brocade Network Advisor User Manual or online help Install Network Advisor 12 2 X on the supported server refer to Data Migration on page 39 4 Restore the server backup from your original server For instructions refer to Restoring data in the Brocade Network Advisor User Manual or online help 5 Install Network Advisor 12 4 1 on your new machine refer to Data Migration on page 39 and migrate your data Migrating data on page 48 Cross OS migration is not supported however you can restore a Windows OS backup to a Linux OS and vice versa If you are migrating from one OS to another complete the following steps NOTE If you are migrating from a pre 12 0 X release you must first migrate to Network Advisor 12 2 X on your current server refer to Table 9 on page 40 for the release migration path 1 Install Network Advisor 12 4 1 refer to Installation on page 1 on the cu
99. sword in the Password field Click Test to test the connection NOTE You can also use the Windows ODBC Driver Manager to add the DSN for the Linux database server Click OK on the Connection Test dialog box Click Save Click OK on the ODBC Data Source Administrator dialog box Installing the ODBC driver on Linux systems You must have the Open Database Connectivity ODBC driver to allow remote clients to export data and generate reports The ODBC driver enables you to configure the data source name DSN for the Network Advisor database To install the ODBC driver complete the following steps 1 Execute the following command in the terminal gt su gt chmod 777 psqlodbc bin gt psqlodbc bin For 32 bit Linux systems the installer file is located where you downloaded the software Download_Home BROCADE Network Advisor odbc Linux psqlodbc bin For 64 bit Linux systems the installer file is located where you downloaded the software Download_Home BROCADE Network Advisor odbc Linux_64 psqlodbc bin On the Setup psqlODBC screen click Next Install the file to the usual location for your system s application files for example opt PostgreSQL psqlODBC on the Installation Directory screen and click Next NOTE If you select an invalid location the ODBC driver is installed in a different location than where the ODBC executable drivers are located On the Ready to Install screen click Next On the Completing the psqlODBC Setup
100. th a logged in user on the X Server based desktop session such as KDE GNOME and so on The DISPLAY can be any host X Server for example DISPLAY can be set to display the configuration to another UNIX system that has an X based desktop Brocade Network Advisor SAN Installation and Migration Guide 11 53 1003747 02 1 Headless installation e Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid value for example to display to the local console export DISPLAY 0 0 orto display toa remote system that has an X Server running export DISPLAY Remote_ IP_Address 0 0 To display to a remote system you need to permit the remote display of the X Server by running the xhost IP command where IP is the IP address of the Network Advisor server host on a local terminal window of the X based desktop of the remote system You may also need to consider a firewall that might block the display to the X Server which listens by default on TCP port 6000 on the remote host e Make sure you test the DISPLAY definition by running the xterm command from the same shell from which you run install bin A new X terminal window to the destination X Server display should open Performing a headless installation on Windows and UNIX systems To perform a headless installation through the CLI download the software refer to Downloading the software on page 7 e For Windows systems compl
101. tions gt Server Backup on the 32 bit Linux server Install the same version 12 2 X 12 3 X or 12 4 X on the 64 bit pure Linux server Select SMC gt Restore to restore the backup on the 32 bit Linux server Install Network Advisor 12 4 1 on the 64 bit pure Linux server Perform seamless migration to Network Advisor 12 4 1 refer to Migrating data on page 48 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Pre migration requirements 3 If you are migrating from Network Advisor 12 2 X 12 3 X or 12 4 X on a 32 bit Linux server to Network Advisor 12 4 1 on a 64 bit Linux server 32 bit compatible complete the following steps 1 Back up the server for Network Advisor 12 2 X 12 3 X or 12 4 X using Options gt Server Backup on the 32 bit Linux server Install Network Advisor 12 2 X 12 3 X or 12 4 X on the 64 bit Linux server 32 bit compatible Select SMC gt Restore to restore the backup on the 32 bit Linux server Install Network Advisor 12 4 1 on the 64 bit Linux server 32 bit compatible Perform seamless migration to Network Advisor 12 4 1 refer to Migrating data on page 48 If you are migrating from a pre 12 2 X release on a 32 bit Linux server to Network Advisor 12 4 1 on a 64 bit Linux server 32 bit compatible complete the following steps 1 a F WN Install and migrate to Network Advisor 12 2 X 12 3 X or 12 4 X on the 32 bit Linux server refer to Supported migr
102. to Configuring an explicit server IP address on page 34 15 Enter your user name and password The defaults are Administrator and password respectively If you migrated from a previous release your user name and password do not change NOTE Do not enter Domain User_Name in the User ID field for LDAP server authentication 16 Click Login 17 Click OK on the Network Advisor Login Banner Cross flavor migration To migrate from Brocade Network Advisor 12 2 X to a non Brocade Network Advisor 12 4 1 complete the following steps 1 Install Brocade Network Advisor 12 2 X refer to Installing the application on page 9 2 Install non Brocade Network Advisor 12 4 1 refer to Installing the application on page 9 Brocade Network Advisor SAN Installation and Migration Guide 53 53 1003747 02 3 Migration rollback 3 Migrate the supported partial or full data from Brocade Network Advisor 12 2 X refer to Migrating data on page 48 to the Non Brocade Network Advisor 12 4 1 by browsing to the Brocade Network Advisor 12 4 1 location on the Copy Data and Setting screen NOTE If the Non Brocade Network Advisor does not support SAN IP it is recommended that you install SAN only Brocade Network Advisor and then migrate to Non Brocade SAN IP Network Advisor Migration rollback 54 NOTE Migration rollback is not supported if you are performing headless migration Migration rollback is triggered when a fai
103. to step 7 Bundled with Fabric OS and lronWare OS devices to manage small IP or SAN networks from a single interface 6 Choose one of the following options on the Server License screen e If you are migrating from a licensed source the source license information displays Click Next Continue with step 7 e If you are migrating from Professional or Trial software to Licensed software browse to the license file xml and click Next Continue with step 7 The License Key field is not case sensitive NOTE Downgrading the license from the current configuration during migration is not supported Brocade Network Advisor SAN Installation and Migration Guide 49 53 1003747 02 3 Migrating data 7 Complete the following steps on the FTP SCP SFTP Server screen The default selection reflects the previous edition configuration a Choose one of the following options e Select Built in FTP SCP SFTP Server to configure an internal FTP SCP SFTP server and select one of the following options Select Built in FTP Server to configure an internal FTP server The internal FTP server uses a default account and port 21 You can configure your own account from the Options dialog box For instructions refer to the Network Advisor User Manual or online help Select Built in SCP SFTP Server to configure an internal SCP SFTP server The internal SCP SFTP server uses a default account and port 22 You can configure your own account from the Options dia
104. twork Advisor 11 2 X Network Advisor 11 2 X gt Network Advisor 12 0 X gt Network Advisor 12 3 X Network Advisor 12 4 1 Network Advisor 11 3 x Network Advisor 11 3 X gt Network Advisor 12 0 X gt network Advisor 12 1 X gt Network Advisor 12 3 X Network Advisor 12 4 1 Network Advisor 12 0 x Network Advisor 12 0 X gt Network Advisor 12 1 x gt Network Advisor 12 3 X Network Advisor 12 4 1 Network Advisor 12 1 x Network Advisor 12 1 x gt Network Advisor 12 3 X Network Advisor 12 4 1 Table 11 shows the direct migration paths from the Network Advisor 12 2 0 or later Professional Trial and Licensed versions For the step by step migration procedures refer to Migrating data on page 48 NOTE Network Advisor 12 2 X includes only 12 2 0 NOTE Network Advisor 12 3 X includes 12 3 0 12 3 1 12 3 2 12 3 3 and 12 3 4 TABLE 11 Network Advisor version migration paths Current version Professional version Trial Version Licensed Version Enterprise Professional Enterprise Plus Network Advisor 12 2 X Professional Yes Yes Yes Yes Network Advisor 12 2 X Professional Plus Trial No Yes Yes Yes Network Advisor 12 2 Xt Professional Plus Licensed No No Yes Yes Network Advisor 12 2 X1 Enterprise Trial No Yes No Yes Network Advisor 12 2 X1 Enterprise Licensed No Yes No Yes Brocade Network Advisor SAN Installation and Migration Guide 41 53 1003747 02 3 Supported migration paths TABLE 11
105. ult is 443 b Enable HTTP redirection to HTTPS by selecting the Redirect HTTP Requests to HTTPS check box When you enable HTTP redirection the server uses port 80 to redirect HTTP requests to HTTPS You can configure the server port settings from the Options dialog box Server Port pane For instructions refer to the Network Advisor User Manual or online help c Enter a port number in the Database Port field default is 5432 NOTE Do not use a port number below 1024 d Enter a port number in the Starting Port Number field default is 24600 NOTE For Professional software the server requires 11 consecutive free ports beginning with the starting port number NOTE For Trial and Licensed software the server requires 11 consecutive free ports beginning with the starting port number e Enter a port number in the Syslog Port Number field default is 514 NOTE If the default syslog port number is already in use you will not receive any syslog messages from the device To find and stop the process currently running on the default Syslog port number refer to Syslog troubleshooting on page 25 f Enter a port number in the SNMP Port Number field default is 162 g Enter a port number in the TFTP Port Number field default is 69 h Click Next If you enter a syslog port number already in use a message displays Click No on the message to remain on the Server Configuration screen and edit the syslog port number
106. unctionality the Large option of the SAN Enterprise edition only supports 5000 switch ports on a 32 bit system Enable feature usage data transfer from the application by selecting the Yes want to participate option If you do not want to participate in feature usage data transfer make sure the No Thank You option is selected You can stop participating at any time To view an example of the usage data click View Example Data To stop participating in feature usage data transfer after configuration refer to Product improvement on page 35 Verify your configuration information on the Server Configuration Summary screen and click Next Complete the following steps on the Start Server screen a Trial and Licensed only Select the Start SMI Agent check box if necessary Only enabled if you enabled SMI Agent on the SMI Agent Configuration screen b Trial and Licensed only Select the Start SLP check box if necessary Only enabled if you enabled SLP on the SMI Agent Configuration screen c Select the Start Client check box if necessary Only displays if you selected SAN with SMI Agent on the Package screen d Click Finish After all of the services are started the Log In dialog box displays To make changes to the configuration you can re launch the configuration wizard refer to Configuring an explicit server IP address on page 34 Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Acce
107. wser operating system and server operating system must be the same NOTE The download client is bundled with the Netwok Advisor server java runtime environment package Brocade Network Advisor SAN Installation and Migration Guide 13 53 1003747 02 1 Client only installation Click the client bundle and download the file Extract the client bundle Navigate to the extract_location bin directory and run the appropraite bat file e For Windows navigate to C Users user_name desktop windows clientbundle bin and run dcmclient bat e For Linux navigate to opt linux clientbundle bin and run dcmclient If you modify the data in the Options dialog box the Client bundle must be triggered manually e For Windows navigate to Install_Home bin and run create client bundle bat e For Linux navigate to nstall_Home bin and run create client bundle The Network Advisor Log In dialog box displays Enter the IP address of the Network Advisor server in the Network Address list NOTE The server must be the exact same version edition starting port number and network size as the client NOTE You can remove a server from the Network Address list by selecting the IP address and clicking Delete Enter your user name and password The defaults are Administrator and password respectively NOTE Do not enter Domain User_Name in the User ID field for LDAP server authentication Select or clear the Save password check box to choose whet
108. ximum paging file size TABLE 7 Linux swap space requirements Installed physical memory RAM size Recommended swap size 4GB 4GB Greater than4GBandlessthan8GB Equaltotheamountof RAM Greater than or equal to 8 GB and less than 64 GB 5 time the amount of RAM NOTE For networks with more than 9000 ports the recommended memory allocation is 6 GB Browser requirements The launch of Network Advisor and the launch of Element Manager Web Tools from the application are supported from the following browsers with a Java plug in e Browsers Windows Internet Explorer 11 0 9 or later on Windows Firefox 24 or later on Windows or Linux Google Chrome 33 or later on Windows e Java Plug ins For the current supported JRE version for Network Advisor and Web Tools refer to the Release Notes NOTE For higher performance use a 64 bit JRE NOTE If the minimum system requirement is not met you will be blocked from the configuration and an error message will be displayed For the website listing patch information go to http www oracle com technetwork java javase downloads index html Brocade Network Advisor SAN Installation and Migration Guide 53 1003747 02 Downloading the software 1 Client and server system requirements NOTE Network Advisor is not Supported in a Network Address Translation NAT environment where the server and client are on different sides of the NAT Server Network Advisor has the following client and