AP Curtain Machine CHAIN_pneg881-030909

image

Contents

1. S201 111011010 1111111111111 nen 32 unane 1 VNR 33 PNEG 881 Curtain Controller 1 Safety Safety Guidelines This manual contains information that is important for you the owner operator to know and understand This information relates to protecting personal safety and preventing equipment problems It is the responsibility of the owner operator to inform anyone operating or working in the area of this equipment of these safety guidelines To help you recognize this information we use the symbols that are defined below Please read the manual and pay attention to these sections Failure to read this manual and its safety instructions is a misuse of the equipment and may lead to serious injury or death 4DANGER AWARNING CAUTION CAUTION NOTE ll This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property
2. 15 16 NOTES PNEG 881 Curtain Controller 8 Parts List Enclosed Limit Switch Assembly SPRKT2430 and SPRKT2460 Only Rett Pat Deseriptim _ 6 s7 Curtain Controller in Swich _ Pe seo CTC a osas im Swich Mounting Pate PNEG 881 Curtain Controller 17 8 Parts List Enclosed Limit Switch Assembly All Other Sprocket Machines PNEG 881 Curtain Controller Enclosed Limit Switch Parts All Other Sprocket Machines nere Pa Description Channel Electrical Box Mounting 4 x 6 Gasket Flat 4 x 6 Box Ld 4 x6 Fiat MEN EI e oons Et e oos et O o onar erransa Adjustment Rod Retainer 4 x 6 e oos ameno o eon mgeUmAsam W Screw MS 10 24 x 1 RHP ZN Grade 2 Screw SMSAB 4 x1 PHP ZN PNEG 881 Curtain Controller 8 Parts List 19 20 8 Parts List Curtain Machine Components PNEG 881 Curtain Controller 8 Parts List Curtain Machine Components Continued Be mm zum B A u A P gt III 8 21 PNEG 881 Curtain Controller 22 8 Parts List Curtain Machine Components Continued lity 52 0202 52 0297 52 0300 D32 0015 EO DES 0900 00 00 0000 00 A l a m i gt PNEG 881 Curtain Controller 8 Parts List Curtain Machine Components Parts List Ref Part Description Qty 6 520010 Puleyspar fe 8 5 8072
3. Curtain Controller Sprocket and Chain Drive Featuring the Header Sprocket System Operation and Installation Manual PNEG 881 umberland Date 03 09 09 PNEG 881 at ee NA abe This equipment shall be installed in accordance with the current installation codes and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installation occurs PNEG 881 Curtain Controller Table of Contents Contents A 4 Sale UNS 4 General Safety S atemen Qnnn HH TT n ng ng ng 5 Chapter 2 OC AS ES EE Me 7 Chapter om Pm 9 Chapter 4 Header Sprocket Pulley lt lt 55c 2 HH TH TH ng TH SE 5P 12 Header Sprocket or Pulley Configurations 21121210111 13110111 1111111 nhu 12 Chapter 5 Sprocket Pulley Cover Mounting lt 1 3H HH TH H TH raras 13 Sprocket Pulley Cover Mounting lns fUCfiOnS c2 1111111111101 11111111 3 1 nrvv seu 13 Era NG 14 Chapter 7 Troubleshooting Guide 22 22 2222 2220222220200n20n00nn0n20nnannunnnnnunnnnnunnnannunnannunnnnnnnnnnnnnnnannnnnnnunnnnn 15 EPER 17 Enclosed Limit Switch Assembly SPRKT2430 and SPRKT2460 Only 17 Enclosed Limit Switch Assembly All Other Sp
4. Figure 10A The Figure 10A shows 1 2 chain cable configuration This means 1 foot 1 of chain movement at the machine equals 2 feet 2 of cable movement at the curtain Figure 10B The Figure 10B shows 1 1 chain cable configuration This means 1 foot 1 of chain movement at the machine equals 1 foot 1 of cable movement at the curtain PNEG 881 Curtain Controller 27 28 10 Wall Mount Outside Endwall Mount for Curtains Continued Illustration shows table configuration of the sidewall Figure 10C The Figure 10C shows 1 1 chain cable configuration This means 1 foot 1 of chain movement at the machine equals 1 foot 1 of cable movement at the curtain Outside Sidewall Mount for Curtains Vertical Installation Figure 10D The Figure 10D shows 1 2 chain cable configuration This means 1 foot 1 of chain movement at the machine equals 2 feet 2 of cable movement at the curtain PNEG 881 Curtain Controller 10 Wall Mount Inside Endwall Mount for Curtains Figure 10E The Figure 10E shows 1 1 chain cable configuration This means 1 foot 1 of chain movement at the machine equals 1 foot 1 of cable movement at the curtain Inside Sidewall Mount for Vent Doors Vertical Installation Figure 10F The Figure 10F shows 1 1 chain cable configuration This means 1 foot 1 of chain movement at the machine equals 1 foot 1 of cable movement at the doors PNEG 881 Curtain
5. 14 Repeat Step 7 through Step 13 for the opposite side 15 Install pulleys brackets hand winches etc according to the appropriate mounting configuration 16 Wire the Curtain Controller to the appropriate control See Wiring Diagrams on Pages 31 and 32 17 Close the curtains vent doors fully using the manual mode of the controls Set the lower limit using the lower limit adjustment collar NOTE Be sure to tighten the limit switch adjustment collar Failure to do so can cause damage to the machine and barn Take up excess slack in the cable using the manual winch while paying close attention not to overtighten 18 Open the curtains vent doors to the desired opening using the manual mode of the controls Set the upper limit switch adjustment collar NOTE Be sure to tighten the limit switch adjustment collar Failure to do so can cause damage to the machine and barn 19 Attach the door to the machine This will protect the integrity of the machine and ensure the safety of those working on or near the machine PNEG 881 Curtain Controller 11 12 4 Header Sprocket Pulley Header Sprocket or Pulley Configurations Pulling two 2 curtains with the Curtain Controller Pulling one 1 curtain to the right of the Curtain Controller Pulling one 1 curtain to the left of the Curtain Controller Curtain Controller is mounted horizontally Remove the cap plugs in the top of the machine and run cables through the top holes
6. Bolt HHCS 5 16 18 x 3 4 ZN HE 9 1858 1147 Split Lock Washer 5 16 ZN Insert Threaded 3 8 16 Flat Washer 3 8 x 1 1 2 x 1 4 TH Bearing 1 Pillow Block w Set Screws Coupler Spider Hytrel 7 8 F LO95 Love Joy Bolt Flange 3 8 16 x 1 ZN Grade 8 Flat Washer 3 8 7 16 I D x 1 O D YDP Bolt HHCS 5 16 18 x 1 ZN Grade 2 Insert Threaded 1 4 20 Steel Zinc Yellow Dichromate Bolt HHCS 3 8 16 x 1 1 2 ZN Grade 8 Lock Nut 1 2 401 ARL Cotter Pin 3 32 x 1 2 ZN Grade 2 CC 50 Sprocket Hardware Kit 36 Machine PNEG 881 Curtain Controller 24 9 Installation Kit AC180 A Installation Kit Purchased Separately Figure 9C AC1822 Assembly AC1820 Bracket Outside Corner Assembly pea Pane o Jar KN BAC1820 Corner Bracket Assembly cz S 9046 Screw Lag 3 8 x 3 HH ZN Grade 2 EN Flat Washer 3 8 7 16 1 D x E S 248 1 0 D YDP g 4 S 6554 6554 Tie Wire 8 Plastic AC1821 Bracket 3 x 3 x 9 2 Pulley Assembly neta Pare Desenpien am Bracket 3 x 3 x 9 for 2 Pulleys 2 8 9206 Bolt U Bolt 3 8 16 x 2 Long x 1 fo eesenovmees E Ty 1902AA Pulley 3 1 2 O D Cast Iron WI AC1822 Bracket 3 x 3 x 3 1 Pulley Assembly ER Rene Pi Fair Pi ham maca uo xo fort Pulley 1 2 jee Bolt U Bolt 3 8 16 x 2 Long x 1 El EN S 456 Hex Nut 3 8 16 YDP Grade 5 ul EN 1902AA Pulley 3 1 2 O D Cast Iron WI Es PNEG 881 Curtain Controller 9 Installation Kit AC180 A Installatio
7. Controller hang the machine on the 3 lag bolt See Figure 3B NOTE The 3 lag bolt should only be used to hang the machine to the wall Do not attempt to operate the machine until it is fully secured Keyhole slot used for machine placement before securing to the wall Figure 3B PNEG 881 Curtain Controller 10 3 Installation 5 Secure the machine to the wall by using the minimum six 6 3 8 x 2 lag bolts provided See Figure 3C Holes on both sides of frame used for mounting the curtain controller to the wall Figure 3C 6 Remove pulley sprocket covers 7 Insert the chain into the top of the machine onto the sprocket and pull down through the machine until the chain reaches the chain adapter See Figure 3D 8 Fasten the chain to the chain adapter by using the master link See Figure 3D Figure 3D PNEG 881 Curtain Controller 3 Installation 9 Cut an opening in the pulley sprocket cover 3 4 x 1 2 where the chain will exit the cover 10 Insert the chain through the pulley sprocket cover See Figure 3E IN Be YS SN ul IN Rh SO s N gt Figure 3E 11 Replace the pulley sprocket cover to the machine 12 Attach chain adapter to the end of the chain and the swivel to the chain adapter See Figure 3F Figure 3F 13 Loop the cable through the swivel and fasten together with three 3 cable clamps
8. Controller 29 30 10 Wall Mount Inside Endwall Mount for Vent Doors Vertical Installation Figure 10G The Figure 10G shows 1 2 chain cable configuration This means 1 foot 1 of chain movement at the machine equals 2 feet 2 of cable movement at the doors Inside Sidewall Mount for Vent Doors Horizontal Installation Figure 10H The Figure 10H shows 1 1 chain cable configuration This means 1 foot 1 of chain movement at the machine equals 1 foot 1 of cable movement at the doors PNEG 881 Curtain Controller 11 Wiring Diagrams Wiring Diagram for 110V 60 Hz GND CONTROL DEVICE SEC SW 1 SEC SW2 L1 COMMON C NC C NC BLACK PRIM SW 1 OPEN zu RED NEUT CLOSE BLACK WHITE RED E PRI LIMIT 1 10V AC OPEN I SEC LIMIT OPEN BLACK SEC LIMIT 7 1 CLOSE BLACK WHITE PRI LIMIT H CLOSE BLACK 5 LW T gall a X Ol r lt m GEAR MOTOR BLACK L1 CAPACITOR TO CONTROL SYSTEM 1 o 9 BLACK COMMON RED OPEN BLACK w WHITE STRIPE CLOSE WHITE 1 Fr SE ERBEN WHITE NEUTRAL GREEN B n 9501511117301 a an an 2 J ELECTRIC BOX GREEN GROUND WIRE CONNECTOR DC 1345 PNEG 881 Curtain Controller 31 11 Wiring Diagrams Wiring Diagram for 220V 50 60 Hz GND an CONTROL DEVICE SEC SW 1 SEC SW 2 L1 COMMON C NC C NC BLACK
9. PNEG 881 Curtain Controller 5 Sprocket Pulley Cover Mounting Sprocket Pulley Cover Mounting Instructions Attaching Pulley Covers to Pre existing Cable NOTE f you do not have pre existing cable drill a 1 4 hole in the appropriate dimple and proceed to Step 4 Step 1 Determine on which side of the machine the pulley cover will be mounted This will affect where the slot will be cut in Step 2 Step 2 Using a saw cut a slot from the bottom of the pulley cover lip to the dimple on the cover s face When slotting the right pulley cover use the right dimple for placement When slotting the left pulley cover use the left dimple for placement See Figure 5A for slot placement Dimples Pulley cover Slot for right side Slot for left side of frame of frame Figure 5A Step 3 Slide the existing cable into the slot until it reaches the dimple Step 4 Remove existing sheet metal screw See Figure 5B for pulley cover fastening Sheet metal screws Figure 5B Step 5 Fasten the pulley cover to the machine using four 4 10 16 x 5 8 sheet metal screws The top of the pulley cover should be flush with the top of the machine PNEG 881 Curtain Controller 13 14 6 Maintenance Safety in Maintenance and Repairs Before starting any repairs or maintenance on you Curtain Controller System or control units observe the following safety steps 1 2 3 Isolate the system from the electricity supply by switchi
10. PRIM SW 1 Ban OPEN NCL Ic F RED PRIM SW 2 CLOSE BLACK WHITE L 220V AC RED BEE PRI LIMIT OPEN Pi SEC LIMIT OPEN BLACK CLOSE BLACK WHITE 3 CLOSE D PRO SG ul 1 I amp E Q x y lt L I m GEAR MOTOR L1 CAPACITOR TO CONTROL SYSTEM 1 amp BLACK COMMON RED OPEN BLACK w WHITE STRIPE CLOSE WHITE 1 EEE o a GREEN 9 L2 GREEN Av spre eye ua ELECTRIC BOX GREEN GROUND WIRE CONNECTOR DC 1346 32 PNEG 881 Curtain Controller GSIGROUP GSD Limited Warranty The GSI Group LLC GSI warrants products which it manufactures to be free of defects in materials and workmanship under normal usage and conditions for a period of 12 months after sale to the original end user or if a foreign sale 14 months from arrival at port of discharge whichever is earlier The end user s sole remedy and GSI s only obligation is to repair or replace at GSI s option and expense products that in GSI s judgment contain a material defect in materials or workmanship Expenses incurred by or on behalf of the end user without prior written authorization from the GSI Warranty Group shall be the sole responsibility of the end user Warranty Extensions The Limited Warranty period is extended for the following prod
11. Curtain Controller System Read this manual thoroughly before attempting any installation or use of the Curtain Controller System Keep this manual with the Curtain Controller System or in a location where it can be readily accessed Failure to read this manual and its safety instructions is a misuse of the equipment Correct Uses of Your Curtain Controller The Curtain Controller System is designed solely for the purpose of controlling vent doors in livestock swine and chicken houses Use of the system in any other way is a misuse of the system and may endanger safety and health Only genuine AP Cumberland parts are to be used in the installation and use of the Curtain Controller System Use of other non genuine parts is a misuse of the system and may lead to dangerous situations imperilling the safety and health of you and others Controls The Curtain Controller is designed for use with manual or automatic temperature control GSI recommends the use of genuine GSI controls Use of any controllers that do not meet this specification can pose a risk to health and safety and will lead to malfunction and failure of the Curtain Controller This machine is not designed for use in atmospheres where there is a risk of explosion Use of the Curtain Controller System in such an environment is prohibited If in doubt contact your dealer or GSI Safety Guards The Curtain Controller System contains many moving and electrical parts which will cause s
12. ION SET FORTH ABOVE SPECIFICALLY GSI MAKES NO FURTHER WARRANTY OF ANY KIND EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE IN CONNECTION WITH i PRODUCT MANUFACTURED OR SOLD BY GSI OR ii ANY ADVIGE INSTRUCTION RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT REPRESENTATIVE OR EMPLOYEE OF GSI REGARDING OR RELATED TO THE CONFIGURATION INSTALLATION LAYOUT SUITABILITY FOR A PARTICULAR PURPOSE OR DESIGN OF SUCH PRODUCTS GSI shall not be liable for any direct indirect incidental or consequential damages including without limitation loss of anticipated profits or benefits The sole and exclusive remedy is set forth in the Limited Warranty which shall not exceed the amount paid for the product purchased This warranty is not transferable and applies only to the original end user GSI shall have no obligation or responsibility for any representations or warranties made by or on behalf of any dealer agent or distributor GSI assumes no responsibility for claims resulting from construction defects or unauthorized modifications to products which it manufactured Modifications to products not specifically delineated in the manual accompanying the equipment at initial sale will void the Limited Warranty This Limited Warranty shall not extend to products or parts which have been damaged by negligent use misuse alteration accident or which have been improperly inadequ
13. ately maintained This Limited Warranty extends solely to products manufactured by GSI Prior to installation the end user has the responsibility to comply with federal state and local codes which apply to the location and installation of products manufactured or sold by GSI 9101239 1 CR rev7 DOG revised July 2009 This equipment shall be installed in accordance with the current installation codes and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made mem 1004 E Illinois St Assumption IL 62510 0020 Phone 1 217 226 4421 Fax 1 217 226 4420 www gsiag com Copyright 2009 by G5D Group Printed in the USA
14. damage NOTE indicates information about the equipment that you should pay special attention PNEG 881 Curtain Controller 1 Safety General Safety Statement Our foremost concern is your safety and the safety of others associated with grain handling equipment This manual is to help you understand safe operating procedures and some problems which may be encountered by the operator and other personnel As owner and or operator you are responsible to know what requirements hazards and precautions exist and inform all personnel associated with the equipment or in the area Safety precautions may be required from the personnel Avoid any alterations to the equipment which may produce a very dangerous situation where SERIOUS INJURY or DEATH may occur Electrical Safety An adequate and safe power supply to the Curtain Controller unit is essential for safety A competent and qualified electrician must undertake all electrical wiring All wiring is to be installed according to the National Standards and Regulations relevant to your Country and Region Electrical safety devices emergency stop and main isolators are provided with the Curtain Controller System and are essential for safety This should be installed as indicated in the enclosed installation instructions and in accordance with the relevant codes and directives User s Manual This manual contains information and instructions essential to the safe installation and use of the
15. erious injury or death iftouched Guards are placed on the machine for your protection Operating the machine at any time with guards removed or incorrectly fitted is a serious misuse of the machine and endangers safety PNEG 881 Curtain Controller 1 Safety Safety in Handling the Curtain Controller System The Curtain Controller weights Model Weight SPRKT2415 SPRKT2430 104 Ibs 47 kg SPRKT2460 SPRKT3615 SPRKT3630 119 Ibs 54 kg SPRKT3660 SPRKT4815 SPRKT4830 135 Ibs 61 kg SPRKT4860 SPRKT6015 SPRKT6030 151 Ibs 69 kg SPRKT6060 All precautions should be taken when lifting and or moving the unit to prevent the risk of physical injury Maximum Load The Curtain Controllers with 15 RPM and 30 RPM gear motors can lift a maximum of 4000 lbs 1814 kg at a 1 2 pulley ratio 60 RPM Gear motors can lift a maximum of 1000 lbs 453 kg at a 1 2 pulley ratio Safety in Maintenance While the Curtain Controller is designed to keep maintenance to a minimum some maintenance will be necessary in the course of the life of the machine Do not attempt any repairs on the machine unless you are competent to do so Remember that the Curtain Controller may operate under automatic control and start without warning Never attempt any work on the Curtain Controller without first isolating the machine from the main power and locking the isolator so that only you can turn the power back ON Follow all guidelines given in the maintenance section of t
16. his manual Before restarting the Curtain Controller ensure that all electrical enclosures are locked closed and all guards and other safety measures are correctly fitted If in any doubt contact your dealer or GSI for assistance Noise Tests on this machine indicate noise levels at a position one 1 meter from the drive unit and 1 6 meters above the ground do not exceed 70 dBa continuous A weighted sound pressure or 63 Pa instantaneous C weighted sound pressure PNEG 881 Curtain Controller 2 Decals Safety Decals and Warnings The following pages show you exactly where the safety signs and warnings decals should be placed on your Curtain Controller If a decal is missing damaged or unreadable please contact your dealer or the GSI group for a free replacement For guidance or assistance on any issues relating to the safe use of the Curtain Controller System Contact GSI Group 1004 E Illinois St Assumption IL 62510 Phone 217 226 4421 Fax 217 226 4420 Decal 889 is located above the electrical box on the outside of the Curtain Controller A4DANGER HIGH VOLTAGE Will cause inju death Jn or death er Lockout power before servicing DC 889 is located on the electrical unit within the Curtain Controller ADANGER HIGH VOLTAGE Will cause injury or death Lockout power before servicing PNEG 881 Curtain Controller 2 Decals r DC 1516 is located on the front cover of
17. n Kit Purchased Separately Continued OIEA u Flat Washer 3 8 7 16 I D x 2 s456 546 Hex Hex Nut 3 8 16 YDP Grades 3 8 16 YDP Hex Nut 3 8 16 YDP Grades 5 E e fore emos sora anos 6 Lo fore emos sore anos 2 e fess poo menasa 1117 mer Po sere fore came conn os m Figure 9D NOTE Assembly parts can be purchased separately AC180 B Installation Kit Purchased Separately AC1821 Bracket 3 x 3 x 9 2 Pulley Assembly DION CN ler EN ng 1821 Bracket 3 x 3 x 9 for 2 ames Bolt U Bolt 3 8 16 x 2 Long x 1 EN S 456 Hex Nut 3 8 16 YDP Grade 5 a EN 1902AA Pulley 3 1 2 O D Cast Iron WI es Figure 9E AC 1821 Assembly PNEG 881 Curtain Controller 9 Installation Kit AC180 B Installation Kit Purchased Separately Continued Re l Part Description Oy o s72 aaniHcssetexerzNonm2 2 a eros Roa Tmeadoszaar10x 17 Grace 2 s serer ane cae camp ZN Pines s_ Figure 9G AC1820C Assembly AC1820C Heavy Duty Outside Corner Bracket Ret Partit Description Qiy 1820C1 Bracket Outside Corner 1 2 S 9206 Bolt U Bolt 3 8 16 x 2 Long x 1 1 Flat Washer 3 8 7 16 I D x 1 O D YDP Hex Nut 3 8 16 YDP Grade 5 Pulley 3 1 2 O D Cast Iron WI 6 s906 Screw Lag 3 8 x 3 HH ZN Grade 2 6 NOTE Assembly parts can be purchased separately PNEG 881 Curtain Controller 10 Wall Mount Outside Endwall Mount for Curtains
18. ng OFF the power isolator and lock it in the OFF position Keep the key in the possession Do not reconnect the power supply until all work is completed and all guards are correctly refitted It is recommended that the end user practices a monthly inspection of the Curtain Controller and all items used in conjunction cables pulleys brackets hand winches etc with the machine 1 Inspect the drive screw Lubricate liberally with a lithium grease of an NLGI No 2 consistency extreme pressure properties Inspect and tighten the locking collars on the adjustment rod to ensure activation of limit switches Inspect cable pulleys brackets hand winches etc for alignment and premature wear Realign and or replace as needed Inspect bearings checking for smooth rotation and listening for squeaks Inspect set screws in couplers and in pillow block bearing Manually run machine in both directions to ensure positive shut off and unrestricted cable movement Inspect drive screw for debris in the threads Debris in threads may cause premature failure of drive block Inspect the thrust bearing Lubricate as needed PNEG 881 Curtain Controller 7 Troubleshooting Guide Possible Cause Corrective Action 1 Will not run in manual mode 1 Control not in manual mode 1 Move switch to manual setting Check 1 Machine operates in opposite direction in response to temperature change 1 Runs in both directions a
19. rocket Machines 18 Curtain Machine Components rrnnnnnnnnnnnrvnrnnnnrrnnnnnrennnnnnsennnnnsnennrnnesennnnnnnnnnnnnesennnnsssnnnnnnsrennnnssennnnnn 20 Chapter 9 SJETTE OG EEE ae 24 AC180 A Installation Kit Purchased Separately ccccoooccnnccconcnncconccnnonnacononnoncnnnononcnnnnnanennnnanenns 24 AC180 B Installation Kit Purchased Separately ccooooncnnccconccncconncnncnnacononnoncncnnnoncnnonnanennonanenns 25 Chapter 10 Wall AA 27 Outside Endwall Mount for Curtains c nennen nnnnnnnnn nennen nnnennnn nennen kh ren 27 Outside Sidewall Mount for Curtains Vertical Installation c lt lt ee nnnnnne nenn 28 Inside Endwall Mount for Cur aifS c0 11111 1n ng TK nh 29 Inside Sidewall Mount for Vent Doors Vertical Installation 2c Rennen nennen 29 Inside Endwall Mount for Vent Doors Vertical Installation lt nennen 30 Inside Sidewall Mount for Vent Doors Horizontal Installation lt lt lt lt lt ss 30 Chapter 11 Wiring Diagrams 2H HH HH TH nn 31 Wiring Diagram for 110V 60 HZ 0S S011 2n 1 ng TT ni ch ng 31 Wiring Diagram for 220V 50 60 HZ
20. the Curtain Controller ACAUTION Automatic equipment May start at any time Lockout power before servicing DC 856 is located on the sides of the Curtain Controller underneath the sprocket covers Moving parts can crush and cut Keep hands clear of sprocket and chain DC 856 m DC 1517 is located underneath the sprocket covers above the warning decal DC 856 on the Curtain Controller A DANGER Moving parts can crush and cut Keep hands clear of sprocket and chain DC 1517 PNEG 881 Curtain Controller 3 Installation This manual outlines the recommended sequence for the installation of the Curtain Controller System Following the sequence will prove the safest and easiest method of installation Above all connection of the system to the electrical mains should be final stage of installation Failure to observe this could lead to a fatal accident 1 Unpack the Curtain Controller and remove the front cover Inspect the machine for visible defects 2 Select mounting configuration See examples of Outside sidewall one 1 curtain outside endwall two 2 curtains and inside endwall two 2 curtains on Page 27 30 3 Screw one 1 3 8 x 3 lag bolt 6 1 2 below the desired height of the Curtain Controller NOTE Leave 1 1 2 between the bolt head and the wall See Figure 3A 1 1 2 between bolt head and the wall Figure 3A 4 Using the keyhole slot in the back of the Curtain
21. ucts Product Warranty Period Warranty prorated from list price Performer Series Direct Drive 3 Y 0 to 3 years no cost to end user AP Fans and Fan Motor oa 3 to 5 years end user pays 25 5 to 7 years end user pays 50 7 to 10 years end user pays 75 Flooring Shea Feedi eeding Watering Systems Grain Systems Portable amp Tower Dryers 2Yeas Farm Fans Portable amp Tower Dryer Frames Zimmerman and Internal Infrastructure Warranty prorated from list price 0 to 3 years no cost to end user 3 to 5 years end user pays 50 Motors burner components and moving parts not included Portable 5 Years Dryer screens included Tower Dryer e screens not included GSI further warrants that the portable and tower dryer frame and basket excluding all auger and auger drive components shall be free from defects in materials for a period of time beginning on the twelfth 12 month from the date of purchase and continuing until the sixtieth 60 month from the date of purchase extended warranty period During the extended warranty period GSI will replace the frame or basket components that prove to be defective under normal conditions of use without charge excluding the labor transportation and or shipping costs incurred in the performance of this extended warranty Conditions and Limitations THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPT
22. utomatic mode but only one direction manual mode 2 Will not run in either direction manual or automatic modes 1 Will not run in automatic but does operate in manual 1 Runs in one direction only both automatic and manual 2 Toggle switch failure Control wired incorrectly Control failure No power circuit breaker or fuse Tripping may indicate machine overload or electrical wire short Repair or replace before reenergizing circuit Motor failure Control failure Primary switch failure Control not in automatic mode Control failure Broken or loose wire for loose wire connection Replace toggle switch Re wire to wiring schematic instruction Check for loose wire connection Replace Control Check main panel circuit breaker or fuse Check control circuit breaker and or fuse Motor designed with internal thermal protection Before replacing allow motor to cool down and reset May indicate machine overload Contact factory for machine restrictions Check to see if secondary switch is not depressed Replace primary switch Move switch to automatic setting Replace control Repair broken or loose wire Limit switch catching on adjustment 2 Free switch and adjust as needed rod mechanism Limit switch failure Replace switch Control failure Replace Control PNEG 881 Curtain Controller