Home
Industrial Field Switch
Contents
1. One frequently used application for the Managed Magnum 6K8 Series Switch copper ports is to connect one of them using a fiber media converter to another Switch in the network backbone or to some other remote 100Mb device In this case it is desirable to operate the fiber link at 100Mb speed and at either half or full duplex mode depending on the capabilities of the remote device Standard commercially available Fast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at 1OOMb fixed speed Attachment to 10 100 auto negotiation ports typically will not work properly The 6K8 Series Switch s RJ 45 ports handle this situation by configuring the ports as per desire through MNS software port settings and can check the port status of each port after the change When Magnum 6K8 Series RJ 45 copper ports are set for auto negotiation and are connected to another auto negotiating device there are 4 different speed and F H modes possible depending on what the other device supports These are 1 100Mb full _ www GarrettCom com 45 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 duplex 2 1OOMb half duplex 3 10 MB full duplex and 4 10 MB half duplex The auto negotiation logic will attempt to operate in descending order and will normally arrive at the highest order mode that both devices can support at that time Since
2. B4 1 UL Requirements for DC powered units Minimum ISAWG cable for connection to a Centralized DC power source Minimum 14AWG cable for connection to a earthing wiring Use only with Listed 10 A circuit breaker provided in building installation Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent ee A Fastening torque of the lugs on the terminal block 9 inch pound max 6 Centralized DC Power Source cable securement use at least four cable ties of 14AWG min to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block B5 0 OPERATION Operation of Magnum 6K8 Series Switches with the optional 48V DC 24VDC and 125VDC power supply is identical to that of the standard AC powered models Similarly to order the optional 24VDC or 125VDC industrial specific power supply factory installed add a suffix of 24VDC or 125VDC after the product s standard model Example Magnum 6K8 Series 24VDC Magnum 6K8 Series 125VDC B7 0 TROUBLESHOOTING Please refer to Section 6 0 for troubleshooting APPENDIX C Internal DC Dual Source Power Option C1 0 SPECIFICATIONS FOR MAGNUM 6K8 SERIES FIBER SWITCH Power Supply Internal 48VDC Dual Source model Dual Src 48V DC Power Connector First Source A A 2nd Source B B GND Terminal for earth or ground wire connection to the hub chassis Inpu
3. Do not change the Blue color DIP Switch setting ever Leave it at factory default 36 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Step 2 Remove Chassis Cover The Magnum 6K8 Series chassis consists of top cover and bottom chassis assembled together with the help of 12 Philips head screws There are 4 screws located on the topside panel of the unit 2 each on both side 8 for bottom chassis base of the unit Remove these screws Once these screws are removed the top cover is easily slide out to the front off the chassis base as shown in the picture above in Fig 3 6 1a Figure 3 6 1a Removing the Top panel from the Chassis base of the unit Caution Be Power LED Pin J5 careful not to NS ar A When the chassis ib top cover has been removed the interior of the unit is exposed Looking down into the Magnum 6K8 Series unit notice that there are PM module installed and daughter module would be facing your eyes on the top installed on the main board with J5 and DSSV pins connected on the right See Figure 3 6 1b below Figure 3 6 1b Magnum 6K8 Series Top view without chassis cover w daughter module on the top Note Un hooked the J5and DSSV connected wire first as shown in Figure above with arrow mark Step 3 Remove front panel faceplate retaining screws and screen plate There are four retaining screws as shown with arrow mark in Fig 3 6 1c holding the faceplate
4. 48vdc power input The PoE modules are also available to mix n match with fiber modules Please check the ordering information Sec 1 2 for all the various PoK PoE module options The LEDs on 6KP8 RJ45 PoE modules are slightly different compared to regular non PoE RJ 45 modules as shown in Fig 2 When the PoE port is in use the PoE LED is ON when connected properly to an 803 af compliant PD device on that port When non PoE devices are connected the POE LED is OFF PoE does not affect operation of Ethernet data traffic LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK ACT as shown in the diagram 2 2 6 Four Port 10 MB and 100Mb mm Fiber ST Modules n COO F GIS 1 TX GLKRX TX GLK RX 5 TEE fee H F H 2 TX ELK RX ab es The 4 port 10Mb ST fiber modules behave the same as the 4 100Mb ST fiber modules except for the 10Mb speed For port numbering ports 1 2 5 6 are present ports 3 4 7 8 are not present There is also a similar 1OOMb fiber SC module 14 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 The default setup on the 1OMb fiber module is half duplex which allows the Magnum 6K8 Series Switch to connect to any 1OMb hub or media converter or almost any other device with a 10Mb fiber Ethernet port The default setting of the 1OOMb fiber module is full duplex User mode control per port through the MNS port settings software i
5. EC type male recessed at rear of chassis Input Voltage 100 to 240 VAC auto ranging Input Frequency 47 to 63 Hz auto ranging Power Consumption 25 watts typical for a fully loaded fiber model 15 watts typical for a 8 port copper only model _ www GarrettCom com a 3 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 DC Power Supply Options 48VDC Power Input Voltage 36 to 70 VDC 24VDC Power Input Voltage 18 to 36VDC 125VDC Power Input Voltage 88 to 300VDC Std Terminal Block GND Power Consumption same as for AC models see above For DC internal power supplies at 48VDC 24VDC and 125VDC including Dual Source options for continuity of operation when either of the DC input sources are interrupted see Appendices B and C Per port MDI or MDIX on RJ 45 The copper daughter board has MDI MDIX Auto crossover on all the RJ 45 ports and eliminate the use of cross over cable between the devices Also port specific user settings such as FDX or HDX copper 10 100 speed can be fixed using software commands Mountings Vertical mounting only Suitable for wall or DIN Rail mounting Agency Approvals Magnum 6K8 UL listed UL60950 cU CE Emissions meet FCC Part 15 Class A IEEE 1613 Class 2 Environmental Standard for Electric Power Substations See also Note for Power Substations in Sections 3 2 4 3 7 1 and 5 2 9 IEC 61850 EMC and Operating Conditions class C for Power Substations
6. as a separate line item following the product model Example Magnum 6K8 48VDC Dual Src 48V_ forthe regular DS model Similarly order the Dual source 24VDC or Dual source 125VDC as a separate line item following the product model Example Magnum 6K8 24VDC OPERATION Operation of the Dual Source Magnum 6Ks 48VDC 24VDC and 125VDC Switch models are identical to that of the standard models 71
7. 10 5 LXSC10 TIERE i N 48 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 5 0 Introduction Magnum 6K8 Industrial Field Switch Port Modules This chapter describes each Port Module PM including appearance functionality and status displays 5 1 Inspecting the Package and Product This section applies only to PMs shipped as separate items 1 e if 6K8 PMs not factory installed in a Magnum 6K8 PM slot Examine the shipping container for obvious damage prior to installing a 6K8 PM notify the carrier of any damage you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 6K8 Series 6K8 series KPMVs Installation instructions with illustrations Remove the 6K8 Series PM s from the shipping container Be sure to keep the shipping container should you need to ship any of the PMs separately at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container if possible Refer to Chapter 5 for specific return procedures 5 2 6KPMV Module Description An important feature of the Magnum 6K8 Series is the use of Port Modules for flexible mixed media connectivity to RJ 45 and fiber media Since the Magnum 6K8 Series Switches have dual speed capability for copper ports the 2 4 6 or
8. 48VDC 24VDC and 125VDC with dual source DC input See the Appendices B amp C of this manual for more details Use an RFQ for other Variations 3 5 Alarm Contacts for monitoring internal power and Software Traps The Alarm Contacts feature standard on Magnum 6K8 Series s provides two Form C Normally Closed NC contacts to which the user can attach two sets of status monitoring wires at the green terminal block When this option is present the terminal block for Alarm Contacts is part of the Power Input panel in the Magnum 6K8 s case The AC or DC power input connection is in the same panel A manual On Off Switch for power to the unit is not available on 6K8 units with the Alarm Contacts option as these two features occupy the same space in the case The first NC Alarm Contact top position is a Software Alarm operated by user settings in the MNS 6K software The user can disable the Software Alarm feature with a software configuration command if desired When the Software Alarm is enabled the Form C Normally Closed NC contact is held close during normal software operation A user defined software malfunction such as an SNMP Trap or a Software Security violation or an S Ring Fault causes the contact to open and thus trigger an alarm in the user s monitoring system The second bottom position NC Alarm Contact is held close when there is power on the main board inside of the 6K8 This provides a Hardware Alarm be
9. ACTIVITY 4 FULLHALF Small Form Factor LC type fiber ports The small sizes of LC connectors provide an advantage of placing more ports on one module The 6K P8 45 2SLC is equipped with 6 10 100 RJ 45 ports and 2 Single mode fiber ports When installed in a Magnum 6K8 Series Switch it supports the standard distances as _ www GarrettCom com 59 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 mentioned on 5 2 4 and the LEDs also act similarly 5 2 12 GBIC SXSC Gigabit fiber L000Mb multi mode SC Connector The Magnum GBIC SXSC is a multi mode Gigabit fiber connector equipped with SC type connectors and can be easily snapped in and out The Gigabit fiber ports are most popular as server to switch and switch to switch applications It supports cable distances up to the IEEE 802 3z standard 1000Mbps distance limits 1 e 550m at full duplex 1 1000Mb Fiber SC 4 10 100Mb The GBIC transceiver has been offered in the modular slot with multiple options as per the user requirement The two Giga port has been offered as GBPM 2OTX fiber or RJ 45 whereas the single Gigabit module comes in two different flavor of G 2 LOOMb fiber ports or G 4 10 100 RJ 45 ports as shown in the above figure The GBIC transceiver is fastened using snap in clips Insert the transceiver take care to insert it the right way up arrows on top until it clicks in space While removing the transceiver press the cl
10. ST type twist lock Fiber optic m mode 100BASE FX Fiber Port LOOOBASE FX GBIC modules Fiber Single mode connector types Fiber Port SC type Fiber optic single mode OOBASE FX Fiber Port LC type Fiber optic SFF single mode 1OOBASE FX Fiber Port IOOOBASE FX GBIC modules LEDs Per Port one set at the port one set on rear top LK Steady ON when media link is operational ACT ON with receiver port activity FDX HDX ON Full Duplex Mode OFF Half Duplex Mode 100 10 ON 100Mbps speed OFF 10 Mbps Operating Environment Ambient Temperature 40 to 140 F 40 to 60 C for UL60950 and Component Parts rating 60 to 205 F 50 to 95 C for IEC 60068 Type Test short term rating Storage Temperature 60 to 210 F 50 to 100 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating humidity protection option Request quote Alarm Relay Contacts One NC indicating internal power one NC software controllable Packaging Enclosure Rugged High strength sheet metal Dimensions 9 8 in H x 5 90 in W x 3 70 in D 24 9 cm H x 15 0 cm W x 9 4 cm D Cooling method Convection fully enclosed elongated dual cavity case used as heat sink designed for vertical mounting no fans Weight 2 1 Ibs 0 95 kg Management Console connector DB 9 for RS 232 null modem cable sometimes called an X modem cable Power Supply Internal AC Power Connector
11. also the same On Magnum 4 2 Combo modules there are four LED s for each RJ 45 port which indicate status as described for the 6K8 RJ45 in Section 2 2 3 above The fiber port LEDs indicate status the same way as described for the SFF fiber modules in Section 2 2 2 above Color coding on the panel of the module shows which LEDs belong to which port The Magnum Combo six port modules are also available with 4 MTRJ 100Mb mm SFF fiber and 2 10Mb fiber mm ST ports or 4 RJ45 10 100 copper and 2 10Mb fiber mm ST ports The 4 RJ 45 2 10 Mb ST operation of the SFF fiber and the RJ 45 half of the module is as described for those port types above For detailed information about 10Mb mm ST fiber half of the module see Section 2 2 5 13 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 2 2 5 New PoE Power Pass through model P6KP8 RJ45 MDIX 10 100Mb 8 port The PoE Power pass through RJ 45 ports act similar to regular RJ 45 ports except they have the 6KP8 45RJ 8 Port 10 100Mb Copper ports capability of providing power on each port to power up the PD devices per the IEEE802 3af PoE standard The Power Pass through PoE modules are totally dependent upon the powerful 48VDC input power supply to support more RJ 45 10 100 ports Each port requires at least 15watts to power up the PoE PD devices Maxm one PoE modules can be configured in the A or B slot of any 6K16s with
12. web sites and catalogs to provide guidance to network designers and installers _ www GarrettCom com 47 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Fiber Speed Port Mode Module 6KP4V 10Mb Multi F10ST Mode MST MSC FX _ mode 6KPV SSC 1300 2 9 125 31 9 0 3 0 14 50 125 23 5 31 5 5 2 0 12 1300 9 125 31 14 i 25 GBIC 1000Mb a 1550 9 125 LXSC25 DIOH GBIC 1000Mb ZW 1550 9 125 21 15 K 17 5 ZXSC40 mone 70 GBIC 1000Mb all 1550 9 125 23 18 20 5 102 ZXSC70 DOUE Note The use of either multi mode or single mode fiber to operate at 100Mbps speed over long distances i e in excess of approx 400 meters can be achieved only if the following factors are both applied e The 100Mb fiber segment must operate in full duplex FDX mode i e the full duplex factory default setting for 100Mbps fiber ports must be used and e The worst case OPB of the fiber link must be greater than the fiber cable s passive Attenuation Attenuation Cable loss LED aging loss Insertion loss safety factor N 6 7 4 8 5 4 E if io an 40 6KPV mode 0 4 1300 9 125 5 34 29 58 32 5 65 SSCL eae tond Multi A 31 90 3 0 15 8 5 5 MTRJ mode 50 125 31 5 5 2 0 12 2 4 0 MEC mode re FX ode 0 55 GBIC 1000Mb Multi 850 62 5 125 9 5 17 5 5 2 12 5 SXSC mode 50 125 10 GBIC 1000Mb A 1300 9 125 20 8 5
13. 08 06 Added POE modules and Dual Giga module info Rev A 03 06 Minor update Rev A 10 05 Initial Release Rev A Rev A 09 05 Draft of Initial Release Rev A www GarettCom com Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 THE MAGNUM LINE Industnal networking products Designed and Manufactured in the USA Overview GARRETTCOM INC OFFERS THE PREMIUM QUALITY MAGNUM LINE OF INDUSTRIAL CONECTIVITY PRODUCTS WITH INDUSTRY STANDARD FUNCTIONALITY AND BUILT IN FIBER CONFIGURABILITY MAGNUM PRODUCTS ARE DESIGNED FOR USE IN DEMANDING INDUSTRIAL GRADE CARRIER CLASS POWER UTILITY AND OEM APPLICATIONS WHERE RELIABILITY IS A PRIMARY CONSIDERATION 6K SERIES MANAGED FIELD SWITCHES GIGABIT 100 AND 10 MBPS FIBER AND COPPER PORTS MIX AND MATCH FEATURES SFF FIBER AND DC POWER IN 1U UNITS DX SERIES SERIAL DEVICE ROUTERS ETHERNET AND SERIAL 4K SERIES SWITCHES 100 AND 10 MBPS COPPER PORTS WITH OPTIONAL FIBER PORT WITH AUTO NEGOTIATING FULL SWITCHING PERFORMANCE QUAD SERIES FIBER SWITCHES 100 amp 10MBPS FIBER AND COPPER PORTS MIXED SPEED AND MIXED MEDIA TYPES FULL SWITCHING PERFORMANCE MP62 AND P62F OUTDOOR ETHERNET SWITCHES FOR TEMPERATURE UNCONTROLLED LOCATIONS 6 10 100 AND 2 100MB FIBER PORTS CAN BE CONNECTED IN STRINGS MIXED MEDIA FIBER HUB 16 PORT 10 100 AUTO SENSING DUAL SPEED 8 PORT AND 16 PORT 10 100 AUTO SENSING HUBS PERSONAL SWITCHES 10 100MB 8 PORT DUAL SPEED A
14. 25Km One IEEE 802 3ab TP port RJ 45 connector GBIC TP One 1000BASE ZX GBIC ZXSC40 port 1550nm single mode SC 40Km One 1000BASE ZX GBIC ZXSC70 port 1550nm single mode SC 70Km The Gigabit ports are set by factory as AUTO by default but can be configured as per the convenience using the MNS 6K management firmware 2 2 8 Packet Prioritization 802 1p QOS Quality of Service means providing consistent predictable data delivery to users from datagram paths that go all across a network As a LAN device the Magnum 6K8 Series can do its part to prevent any QOS degradation while it is handling Ethernet traffic through its ports and buffers The Magnum 6K8 Series switching hardware supports the IEEE 802 1p standard and fulfills its role in support of QOS giving packet processing priority to priority tagged packets according to the 802 1p standard In addition to hardware support for QOS the MNS software Rel3 supports two priority queues that can be shared across the eight levels of defined packet priorities for application specific priority control by the user through software configuration settings _ www GarrettCom com 17 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 2 2 9 Frame Buffering and Flow Control Magnum 6K8 Series s are store and forward switches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique
15. Ethernet IEEE 802 1p Priority protocol IEEE 802 1d Spanning tree protocol IEEE 802 1g VLAN Tagging IEEE 802 3x Flow Control IEEE802 1lad Link aggregation Maximum 10 Mbps Ethernet Segment Lengths Unshielded twisted pair 100 m 328 ft Shielded twisted pair 150 m 492 ft 1OBASE FL multi mode fiber optic 2 km 6 562 ft 1OBASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard Fast Ethernet Segment Lengths 1OBASE T CAT 3 4 5 UTP 100 m 328 ft 100BASE TX CAT 5 UTP 100 m 328 ft Shielded twisted pair 150 m 492 ft 1OOBASE FX half duplex multi mode 412 m 1350 ft 1OOBASE FX full duplex multi mode 2 0 km 6 562 ft 1OOBASE FX half duplex single mode 412 m 1350 ft 1OOBASE FX full duplex single mode 20 0 km 66K8 Series ft 1OOBASE FX full duplex Long Reach 40 0 km 122K ft Maximum Standard Gigabit Ethernet Segment Lengths 1OOOBASE T CATS5e or higher is recommended 100 m 328 ft 1OOOBASE SX full duplex multi mode 62 5um cable 220m 1OOOBASE SX full duplex multi mode SOum cable 550m 1OOOBASE LX full duplex single mode 62 5um cable 5Km Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Fiber Multi mode connector types supported Fiber Port ST type twist lock Fiber multi mode 1OMb 1OBASE FL Fiber Port MTRJ type plug in SFF Fiber multi mode 100BASE FX Fiber Port SC type snap in Fiber optic multi mode 1OOBASE FX Fiber Port
16. Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 optimal cooling of internal components without any ventilation openings This sealed case design enables the unit to operate in temperature un controlled environments achieve high EMI noise immunity and provide an un matched IP53 physical protection rating against dust dirt insects and liquid spills http www garrettcom com Pictorial 6k amp _pictorial pd High performance features include non blocking speed on all ports and 802 1p QoS Traffic Prioritization Magnum 6K8 Series switches are plug and play ready for use as backbone switches where a mix of bursty data traffic and priority streaming traffic for VoIP and audio video Triple Play applications are present Magnum 6K8 Series Fiber Switches are provided with LAN management software including SNMP Tag and Port based VLANs IGMP Snooping and Port Security with control via secure Web and command line interface CLI Loaded with secure features like Radius server 802 1x TACACS SNMPV3 and Port Security allow this Industrial Field Switch to qualify for a sub standard managed switch to meet the Industrial expectation For high availability Redundant LANs using ring mesh topologies Spanning Tree Protocol Rapid Spanning Tree Protocol Link Loss Learn and S Ring ring only are available See the Managed Networks Software MNS 6K and S Ring datasheets for additional details on the comprehensive s
17. Magnum 6K8 Series Switch is a straightforward procedure see INSTALLATION Section 2 6 the operation is also straightforward and is discussed in Section 4 Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum 6K8 Series Switch is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support 6 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable d Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems a Make sure that an AC power cord is properly attached to each Magnum 6K8 Series Switch unit Be certain that each AC power cord is plugged into a functioning electrical outlet Use the PWR LEDs to verify each unit is receiving power _ www GarrettCom com 62 Magnum 6K8 Series Industr
18. NEMA TS 2 and TEES for AC powered and PoE powered traffic control equipment Note These products are tested and approved under IEC61850 for use in Class C sheltered locations where neither temperature nor humidity are controlled The equipment needs to be protected against solar radiation rainfall other precipitations and wind UL has not approved these products for Annex T outdoor use Warranty Three years per UL 60950 temperature rating Made in USA Email sales GarrettCom com for details Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 1 2 Ordering Information Magnum Industrial Field Switch 8 ports max MODEL DESCRIPTION Magnum 6K8 Managed Industrial Field Switch base unit for vertical mounting Worldwide AC power May be configured with a selection of 10 100 1000 fiber and copper port connector types 8 total ports max for 10 100Mbps or 2 ports maxm for Gigabit ports Two metal brackets for vertical wall or panel mounting Wire speed filtering and forwarding across all ports 802 3x flow control 802 1p priority packet processing self learning 4K node address table large 240KB packet buffers for 10 100 and 120KB for 1OOOMb For licensed managed networks software MNS 6K and S ring See separate data sheets Magnum 6K8 24VDC Same as 6K8 except the power input is 24VDC Magnum 6K8 5VDC Same as 6K8 except the power input is regulated SVDC amp fused Magnum 6K8 48VDC Same as 6K8 except the po
19. and is transparent to an observer Another feature implemented in Magnum 6K8 Series Switches is a collision based flow control mechanism when operating at half duplex only When the Switch detects that its free buffer queue space is low the Switch prevents more frames from entering by forcing a collision signal on all receiving half duplex ports in order to stop incoming traffic The flow control option is user configurable enable disable through the setport command of MSN 6K software as per the requirement of a network 2 2 10 Managed Network Software MNS 6K for Magnum 6K8 Series Magnum 6K8 Series comes with licensed MNS 6K Firmware Rel 3 2 which allows the configuration of the Magnum 6Ks as a Managed Switch and also allows other _ www GarrettCom com 18 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Software enabled features For additional information about MNS 6K see the Magnum 6K8 Series MNS Software User guide in PDF format a separate document normally accessed via your web browser at ftp ftp garrettcom com or FTP client program at ftp GarrettCom com Use the following to log in User m6kuser Password m6kuser All MNS 6K software information including new releases and upgrades related to MNS 6K software can be accessed and download from GarrettCom s FTP site Alternatively for documentation and latest information or needed GarrettCom proprietary MIBs for SNMP please go
20. auto negotiation is potentially an externally controlled process the original highest order mode result can change at any time depending on network changes that may occur If the device at the other end is not an auto negotiating device the 6K8 Series s RJ 45 ports will try to detect its idle signal to determine 10 or 100 speeds and will default to half duplex at that speed per the IEEE standard General information Auto negotiation per port for 802 3u compliant switches occurs when the devices at both ends of the cable are capable of operation at either 10 Mb or 100Mb speed and or in full or half duplex mode and can send receive auto negotiation pulses and the second of the two connected devices is powered up 1 e when LINK is established for a port or the LINK is re established on a port after being lost temporarily e NOTE Some NIC cards only auto negotiate when the computer system that they are in is powered up These are exceptions to the negotiate at LINK enabled rule above but may be occasionally encountered When operating in 1OOMb half duplex mode cable distances and hop counts may be limited within that collision domain The Path Delay Value PDV bit times must account for all devices and cable lengths within that domain For Magnum 6K8 Series Fast Ethernet switched ports operating at 1OOMb half duplex the bit time delay is 5OBT 4 4 Flow control IEEE 802 3x Standard Magnu
21. combination of multiple possible configurations multiple power options a hardened enclosure and MNS 6K management software makes the Magnum 6K8 a very powerful effective and reliable managed Field Switch providing a secure solution for many needs Setting a new standard for Industrial and Carrier Class applications heavy duty Ethernet Switch requirements are readily accommodated with an extended temperature rating of 40 C to 60 C calculated by the UL Component Parts method or 50 C to 95 C by the IEC 60068 calculated by the Type Test method With various Power Supply options such as all popular DC power input types worldwide AC power and DIN Rail mounting the hardened Magnum 6K8 Series is a multi purpose Industrial Ethernet Switch The extremely versatile options of various port modules offer all fiber media possibilities including small form factor all connector types multi and single mode and 10 100 MB auto negotiating RJ 45 ports Standard GBIC ports can be configured for a variety of Gigabit cabling types and distances For details about module configurations please go to http www garrettcom com techsupport insertion_guides 6k8cg pdf Advanced thermal design techniques patent pending transform the tough metal case into a heat sink as well as a shield for reducing electrical noise and providing physical protection The unique design features an elongated dual cavity shape for _ www GarrettCom com 8
22. connectors latched up securely Figure 3 6 2f Securely latching up 6KPMV Cards into a Magnum 6K8 Series WM a s Ze ves 2 S ge z BS roror si mnam S s a Step 6 Now Screw down the daughter board with 6 440 screws so that it holds the daughter board securely The figure on the left shows the top view of successfully installed 6KPMV cards inside and the Power Led pin J5 and Power supply cable pin DSSV connected to the board pins as shown in Fig 3 6 2g with arrows Fig 3 6 2 Top View 6KPM Module installed and insight for connecting two wires to the right pins Step 7 Once the installation of granddaughter and daughter modules is done the front panel screen plates of 6KPMV need to be placed on the face of the module securely and carefully Now screw down properly the faceplate with 4 screws to complete the installation process for port module The front panel screen plate does not need any screws to hold on port module but need to place tightly and carefully while placing on LEDs Fig 3 6 2h sliding in the top cover onto the chassis base track Step 8 Once 6KPMV card have been installed including faceplate and screen plate the chassis cover should be replaced Make sure the chassis top cover is aligned properly to the base before securely sliding the chassis base track inside the top cover properly as shown in Fig 3 6 2h _ www GarrettCom com a 40 Magnum 6K8 Seri
23. of the 7 chassis Figure 3 6 1c Top View 6KPM retaining screws hold Face Plate 37 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Figure 3 6 1d Removing PM screens Plate Tee Once opened all the four retaining screws the front cover can be removed easily as shown in Fig 3 6 1d To the left Carefully remove the PM screen plate using finger or small screwdriver to come out easily as shown in Fig 3 6 1d on the right Just be careful on the LEDs placed both side and hold the faceplate tightly There are no screws used on holding the screen faceplate Figure 3 6 1d Removing Face Plate 3 6 2 Installing 6KPM Cards in the Magnum 6K8 Series Only one front mounted 6KPMV Module may be installed in one Magnum 6K8 Series Field Switch unit Follow these steps to install a 6KPMV Step 1 Remove top chassis cover See procedure in Section 3 6 1 above Fig 3 6 2a A Magnum 6K8 unit with main board motherboard only Step 2 Place Granddaughter board as shown in fig 3 6 2b on the chassis built in stand off female provided at the front of the 6K8 Series Main Board To place the Granddaughter board Fig 3 6 2b Granddaughter Board shown separately on the chassis as shown in Figure below 3 6 2c screw down tightly with the three 5 16 stand off male on the top of the Granddaughter board The three 5 16 stand off has been used to place the daughter board on the top of the granddaugh
24. terminal block on the Magnum 6K8 Series Managed Switch is located on the left front of the unit and is equipped with three 3 screw down lead posts The power terminals are identified as positive and negative and they are floating inside the unit so that the user if desired may ground either The chassis is earth ground The connection procedure is straightforward Simply insert the DC leads to the Switch s power terminals positive and negative screws Ensure that each lead is securely tightened NOTE Always use a voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at the last When power is applied the green PWR LED will illuminate Note The GND should be hooked up first The 6K8 Series unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use _ www GarrettCom com 67 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Before connecting hot lines to the Terminal Block of 48VDC 24VDC or 125VDC always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage lead from 48V or 48V supply must be connected to the post labeled
25. to www GarrettCom com techsupport index htm software and look for Magnum MNS 6K info Magnum MNS 6K Operator Training This interactive training software instructs on all the basic and advanced information about the Magnum MNS 6K management software and is a useful tool for the first time user Finally please email support GarrettCom com for further information For upgrading the Magnum 6K8 Switch to its latest Magnum 6K Firmware follow through the steps and instruction provided on http www garrettcom com techsupport software upgrade_mns6k pdf 2 3 Features and Benefits E Managed switching for high performance Ethernet LANs Magnum 6K8 Series Switches provide non blocking all ports can run at full speed at once performance with standard Managed Networks Software MNS 6K included They are typically used in LAN traffic centers with 16 1OOMb or 8 2 Gigabit ports for backbone connections where managed network services are desired E Switching services includes 802 1p QoS packet prioritization The Magnum 6K8 Series switching hardware supports QoS giving packet processing priority to priority tagged packets according to the EEE 802 1p standard For port and application specific priorities of data the QoS software may be configured _ www GarrettCom com 19 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 E Large selection of built in fiber options at 10 100 1000Mb Magnum 6K
26. to the 6KS It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce kigh greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The 6KS passes the 1613specifications for zero packet loss with fiber ports amp with RJ45 ports used as indicated here 3 2 5 Connecting Twisted Pair CATS5E or better Unshielded or Shielded The RJ 45 Gigabit ports of the Magnum 6K8 Series can be connected to the media types IOOOBASE T or CAT 5E or better 100 ohm UTP or shielded twisted pair STP balanced cable The CAT 5E or better 100 ohm UTP or shielded twisted pair STP balanced cable is recommended to use when making 1 OOOBASE TX connections In either case the max distance for unshielded twisted pair cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 5E 1000BASE T RJ 45 NOTE Itis recommended that high quality CAT 5E cables which work for both 100 Mb and 1000Mb be used whenever possible in order to provide flexibility in a mixed speed network The following procedure describes how to connect a LOOOBASE T twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 1000Base T connections require that all four pairs or wires be connected Insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note th
27. 0Miys 8 H E Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 PWR POWER Power LED ON when external power is applied to the unit LK LINK Steady ON Link status for 10 Mbps and 100Mbps operation ACT ON with port activity for 10 Mbps and 100Mbps operation F H Full Half duplex LED ON when the port is running full duplex OFF for half duplex 10 100 Speed LED ON when the speed is 100Mbps OFF when the speed is 10 Mbps 4 3 Auto Cross MDIX and Auto negotiation for RJ 45 ports The RJ 45 ports independently support auto cross MDI or MDIX in auto negotiation mode and will work properly with all the other connected devices with RJ 45 port whether it supports Auto negotiation or not e g 10Mb Hub media converter or fixed mode at 10Mb or 100Mb Half Full Duplex managed switch No crossover cable is required while using the 6K8 s copper port to other devices Operation is according to the IEEE 802 3u standard The Managed 6K8 Series Fast Ethernet copper ports can be set for either fixed 100Mb speed or for 10 100 F H N way auto negotiation per the IEEE802 3u standard The selection is made via MNS software The factory default setting is for auto negotiation At 10Mb or 100Mb fixed speed the user may select half or full duplex mode by MNS Software for each RJ 45 port separately For detail information See Section 10 1 at page no 52 of this manual to access the 6K MNS Rel 3 Software user guide
28. 10 100 RJ 45 ports and 4 MTRJ fiber ports When installed in a Magnum 6K8 Series Switch it supports the LINK 2 rn standard distances as mentioned on 5 2 3 and the LEDs also act 3 4 ACTIVITY FULL HALF similarly 5 2 7 6KP8 MLC 8 ports 100Mbps multi mode LC connector Small Form Factor _ ww GarrettCom com 55 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Magnum 6KP8 MLC is a eight 8 Port 100Mbps multi Mode LC fiber port multi mode fiber LC connector small form factor used primarily in 100Mbps fiber to the desktop links When installed in a Magnum 6K8 Series Switch it supports fiber optic cable distances up to the IEEE standard 100Mbps distance limits 1 e typically 2km at full duplex and 412m at half duplex The compact size of the LC Connector reduces the size of wiring panels in wiring closets while providing the advantage of future proof fiber optic technology The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly inserted Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and a FDX HDX LED indicating full duplex mode when lit or half duplex when off 5 2 8 6KP8 45LC Combo 4 100Mbps multi mode LC small form factor and 4 10 100 Mbps RJ 45 Connector The Magnum 6KP8 45LC
29. 32 X 3 8 PHIL PAN w star washer The two heavy duty Din Rail latches are designed as if that they can be manually accessed from the top when the 6K8 is installed on a DIN Rail To install the 6K8 with the DIN Rail brackets and latches attached to it hold the 6K8 in the vertical position with the bottom out and with the top moved in toward the DIN Rail Position the latches over the top of the DIN Rail Then snap the latches into holding position by moving the bottom of the 6K8 inwards to a vertical position The DIN Rail latches and brackets are heavy duty and will hold the 6K8 securely in position even with cabling attached to the unit To release the 6K8 from the DIN Rail mounting press the top of the two DIN Rail latches down simultaneously to release the 6K8 so that it can be dismounted by pulling the bottom out _ www GarrettCom com 30 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Once the bottom of the 6K8 is rotated out the DIN Rail latch is not engaged and the 6K8 can be moved up and out free of the DIN Rail mounting The picture below is a front right side view of a DIN Rail mounted 6K8 It shows vertical mounting of Magnum 6K8 on a DIN Rail track for proper convection cooling of the unit Note that there is air space in the rear as the 6K8 unit is held out from the rear of the panel by the mounting brackets The 6K8 design uses the case for cooling patent pending a
30. 4 2 module with 4xRJ 45 ports and 2x40km single mode FX SC 6KP6V MTIOST 4 2 module with 4xMTRJports and 2x10Mb 2km FL ST 6KP6V RJIOST 4 2 module with 4xRJ 45 ports and 2x10Mb 2km FL ST Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 6KP5V G4RJ 6KP3V G2SC GBPMV 20TX GBPMV COTX G 4 modules with one GBIC receptacle for one user selectable GBIC transceiver see below with 4 fixed 10 100 RJ 45 ports G 2 module with one GBIC receptacle for one user selectable GBIC transceiver see below and 2 100Mb 2km FX SC fiber ports Two port Gigabit module for 6K8 Series Switches with two GBIC receptacles for user selectable GBIC transceivers see below One slot Gigabit module for 6K8 Series Switches with one GBIC receptacle for a user selectable GBIC transceiver module see below GBIC 1000Mb Transceiver options for Mangum 6K8 Series GBIC SXSC GBIC LXSC10 GBIC LXSC25 GBIC ZXSC40 GBIC ZXSC70 GBIC TP CONSOLE CBL One 1OOOBASE SX port with 850nm multi mode SC fiber connector One 1IOOOBASE LX LH port with 1310nm single mode SC 10km fiber connector One 1OOOBASE LX LH port with 1310nm single mode SC 25km fiber connector One 1OOOBASE ZX port with 1550nm single mode SC 40km fiber connector One 1OOOBASE ZX port with 1550nm single mode SC 70km fiber connector One 802 3ab LOOOBASE T port RJ 45 connector Industry standard serial cable DB 9 co
31. 8 Series Industrial Field Switches are designed to naturally include fiber ports and support mixes of multi mode and single mode 10 Mb 100Mb and 1000Mb speed full and half duplex classic Small Form Factor SFF and GBIC fiber connectors RJ 45 10 100 ports can also be configured in the mix of port types E S Ring and Link Loss Learn for reliable high availability using ring topology S Ring and Link Loss Learn provide reliable fast recovery of a fault in ring topology E Relay Contacts for monitoring internal power and user defined software events Two Alarm Relay contacts monitor basic operations One is for hardware and will signal loss of power internally The other is software controllable and will signal user defined software event traps such as a security violation or an S Ring fault condition E Vertical mounting for efficient convection cooling no fans extended temp Vertical mounting brackets are included DIN Rail mounting hardware is optional Ethernet signal and power cables attach in the bottom Two sets of status LEDs are on the switch one set viewable at the port connector and one set viewable from the front E Standard AC power input 48VDC or 24VDC or 125VDC input is optional Standard AC power input is IEC plug auto ranging for worldwide use For special applications models with 48 VDC or 24VDC or 125VDC are available Dual Source DC input can also be selected and configured on the DC power input models E Heavy dut
32. 8 port interfaces are designed to support all standard Ethernet media types at 10 or 100 or 1000Mps speed Each 6K8 Series PM provides a wide selection of connecting Ethernet media segments with all similar or combo connector type Note The 6K8V Port modules are exactly similar in the functions size and price compared to 6K8 but addressed as e g 6KP8V RJ45 For a correct list of 6KS8 Port Module types refer to Section 1 2 Each 6K8 Series PM is individually described in the following sections NOTE The 10 100 RJ 45 ports on all the modules either all RJ 45 ports or used for COMBO module are featured with Auto negotiation and Auto Cross MDIX _ www GarrettCom com 49 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 5 2 1 6KP6 RJMST 4 10 100Mbps RJ 45 and 2 100Mb multi mode FX ST twist lock Combo Module The Magnum 6KP6 RJMST is a combo 6 port module of four RJ 45 s at 10 100Mbps and two fiber optic ports at 100MB The Combo module is equipped with dual mode ST type connectors 6KP6 RJMST 4 Port 10 100Mbps and 2 100 Mb ST Fiber Port and dual speed copper ports The ST connector functions as a fiber optic transceiver to support OOBASE FX network E er ie L i segments When installed in a i gt tie Magnum 6K8 Series Managed IX DK kx Switch the copper port C1 LINK a 10 100 supports the standard distance ACTIVITY 4 FULL HALF 100m on each port and the fiber
33. Ds Keep an open area around the unit so that cooling can occur from convection while the unit is in operation The 6K8 Series has no fans so it is silent when in operation Internal electronics use the case as a heat sink so the unit may normally be quite warm to the touch 3 2 Connecting Ethernet Media The Magnum 6K8 Series Switches are specifically designed to support all standard Ethernet media types within a single Switch unit This is accomplished by using a family of different port Modules that can be individually selected and configured per port See Section 2 4 for a description of the PMs The various media types supported along with the corresponding IEEE 802 3 802 3D 802 3u 802 3AB and 802 3z standards and connector types are as follows IEEE Standard Media Type Max Distance Port Module Fiber mm Fiber sgl m Fiber mm Fiber sel m Fiber small form factor mm Fiber small form factor sgl m Fiber Copper 10BASE T 100BASE TX twisted pair 1000BASE TX 1000BASE FX 100BASE FX l mm multi mode 220m ft GBIC SXSC 5 10 25 70Km GBIC LXSC 2 0km 6 562 ft 6K6 MSC MST 18 0km 95K ft SSC SSCL 2 0km 6 562 ft 6K8 MTRJ MLC 15 km 6KP8V SLC 100m 328 ft 6K8 RJ45 GBPM RJ45 2 sgl m single mode 26 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 3 2 1 Connecting Fiber Optic ST type twist lock The following procedure applies to installations using a PM wit
34. LED is ON 1OOMbps if it is OFF 1OMbps 5 2 1b 6KP4 F10ST 4 10Mb multi mode FX ST twist lock Module The Magnum 6KP4 F10ST 6KP4 RJ10MST is a 1OMb multi mode 4 Port 10Mb ST Fiber Port fiber module with 4 ST Fiber ports All four fiber ports are ST connectors and configured as 10Mb 3 half duplex by default The 10Mb ST fiber ports allow the user to connect their legacy 10Mb network to the Magnum 6K8 Series switch They also provide a convenient way for the half duplex Hub to connect to the switch through 10Mb fiber ports It supports distances according to the 10Base FL standard i e 2Km distance for multi mode fiber Single mode for 10Km distance may be available as a special order Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and FDX HDX LED 6KP4 RJ10MST indicating full duplex 4 Port 10Mb ST Fiber Port mode when lit or half duplex if off 5 2 lc 6KP4 FLSTFX 2 10Mb amp 2 100Mb multi mode FX ST twist lock Module The Magnum 6KP4 j 3 FULL HALF FLSTFX is a combo fiber _ www GarrettCom com a 51 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 module with two 1OMb two 100Mb multi mode fiber module and in combine 4 ST Fiber ports All four fiber ports are ST connectors and configured as 1OMb half duplex by default for 1OMb fibe
35. Module is a combo 4 Port 10 100Mbps amp 4 port 100Mbps module with a combination of Multi Mod LC ON copper and Fiber Small Form Factor LC type ports The TE E small size of LC connectors allows an advantage of having more ports on one module y A The 6KP8 45LC is equipped 3 with 4 10 100 RJ 45 ports and 4 LC Small form factor LINK 10 10 multi mode fiber ports G ACTIVITY 4 FULL HALF ein it m LKE o LK LK 56 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 When installed in a Magnum 6K8 Series Switch it supports the standard distances as per mentioned on 5 2 8 and the LEDs also act similarly as mentioned above 5 2 9 6KP8 RJ45 Twisted Pair 6KP8 RJ45 10 100Mb 8 Port 8 Port 10 100Mb Copper ports The 6KP8 RJ45 module supports D Ethernet twisted pair segments of any standard length It is equipped with an eight port RJ 45 connector and offers 10 100 full half duplex auto negotiating capability on each port The RJ 45 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections The 6KP8 RJ45 modules are equipped with a Media Dependent Auto Crossover MDI X switch which controls all ports for cascaded connection This feature eliminates the need for a special twisted pair crossover cable when connecting to a hub or another switch Each port has an Activi
36. OTE It is recommended that high quality CAT 5 cables which work for both 10 Mb and 100Mb be used whenever possible in order to provide flexibility in a mixed speed network since dual speed ports are auto sensing for either 10 or 1OOMDY s The following procedure describes how to connect a LOBASE T or 1 OOBASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 Using standard twisted pair media insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established 4 The auto cross Auto MDIX feature will eliminate the use of crossover cable while connecting the RJ 45 ports to any other RJ 45 device _ www GarrettCom com a 28 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity 1 e less than 2 meters or 6 5ft
37. RJ 45 ports except they have capability of D PoE C4 FULL HALF providing power on each port to power up the PD devices per the IEEE802 3af PoE standard The Power Pass through PoE modules are totally dependent upon the powerful 48VDC input power supply to support more RJ 45 10 100 ports Each port requires at least 15 watts to power up the PoE PD devices In this Fig the top 8 RJ45 ports are enhanced with POE option The 8 RJ45 POE modules are also available with mix n match with fiber modules Please check the ordering information Sec 1 2 for all the various P6K PoE modules option The LEDs on 6KP8 RJ45 PoE modules are slightly different compared to regular non PoE RJ 45 modules as shown in Fig 2 When the PoE port is in use the PoE LED is ON when connected properly to an 803 af compliant PD device on that port When non PoE devices are connected the PoE LED is OFF PoE does not affect operation of Ethernet data traffic LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK ACT as shown in the diagram PoE LEDs Summary e For PoE devices each RJ 45 PoE port supports only 802 3af complaint devices The PoE LED is ON when the attached PD is drawing power from the port e For non PoE devices connected the PoE port will act as a normal RJ 45 port and the PoE LED is OFF No power is being sent out from the port e The PoE ports in Magnum 6K s with 48VDC power input act as a pass throu
38. Rail clip must be on top while positioning the clip as shown in Fig 2b with arrow mark Fig 2a 10 32 Screws on indented side Fig 2b Din Rail assembly w plate applied to mount the Din Rail assembly underneath 5 Remount the Din Rail assembled plate onto the Magnum 6K8 using the 4 40 screws Note Torque 5lb in max on the 4 40 screws while tightening the screws The final Din Rail assembly mounted on the Magnum 6K8 is shown below on Fig 3 32 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Fig 3 3 3 2 Mounting Dimensions for 6K8 with metal brackets Each Mangum 6K8 is supplied with metal mounting brackets and screws to mount the unit securely It is recommended to mount the 6K8 vertically as shown below for proper cooling and long life reliability It is also advisable to mount the unit with space for air movement around the top and the sides typically a minimum of 1 inch Note that the back of the 6K8 unit is held out from the panel or wall behind it creating a rear space of about 4 inch or lcm This allows air circulation and cooling of the rear part of the case Since the 6K8 uses special internal thermal techniques patent pending to move the heat generated by the electronic components inside into the case the case may be quite warm to the touch during normal operation 33 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 The unit can be m
39. SC type connectors It provides a combination of copper and Fiber functions in one module to the 6K8 Series Switches supporting four Copper and two single mode Long Reach fiber network segments The 6KP6 RJSSC when installed in a Magnum 6K8 Series Switch has copper supporting the 100m distances and Fiber supporting single mode fiber cable lengths of as much as 40 Km see Power Budget Section 4 5 Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and a _ www GarrettCom com a 53 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 FDX HDX LED indicating full duplex mode when lit or half duplex when off The 10 100 LED indicates the speed for the copper port which is 1 OOMbps when the LED is ON and 10 MB when the LED is OFF 5 2 4a 6KP6 RJ10ST 4 10 100 MB copper port and 2 10Mbps multi mode FL ST type twist lock connector The Magnum 6KP6 RJ10ST is also a Combo module equipped with 4 dual speed copper ports and 2 multi mode 10 MB fiber ST type connectors It provides a combination of copper and Fiber functions in one module to the 6K8 Series Switches supporting four Copper and two 10Mb of ST fiber network segments The 6KP6 RJIOST when installed in a Magnum 6K8 Series Switch has copper supporting the 100m distance and Fiber supporting multi mode fiber cable allow to connect the legacy netwo
40. Series Console Port the RS 232 port on the 6K8 Series Switch to the your PC so that your PC becomes the 6K8 Series s Console Terminal For Hyper terminal configuration to communicate with 6K Series Switches please follow the Quick Step Guide come along with the Switch http www garrettcom com techsupport software upgrade mns6k pdf Note A console cable either of the two types may be purchased as a separate item with the 6K8 Series unit They are not bundled with the unit Console or Serial DB 9 Port Fig 3 7 Enlarged view of Magnum 6K8 Series Console Port area Note For a detailed description of Managed Network Software MNS 6K and Magnum 6K8 Series Switch configuration for Network Management please refer to Magnum 6K8 Series Software Manual available on GarrettCom s FTP site Please refer Section 2 2 9 of this manual for download information 42 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 3 7 1 RS 232 DB 9 Console Com port Serial port pin assignments DB 9 Console port connector Pin Signal Description 1 CD Carrier detect not used 2 RXD Receive Data input 3 TXD Transmit Data output 4 open not used 5 GND Signal Ground 6 9 open not used The above information enables a management station a PC or Console terminal to connect directly to the Switch Console using a straight through serial cable NOTE for Power Substations In support o
41. UTO NEGOTIABLE WITH FIBER OPTION PERSONAL HUBS 100MB OR 10 100MB 8 PORT WITH 2 SWITCHED PORTS 1 FIBER BUILT IN PERSONAL HUBS 10MB SERIES 8 PORT AUI STACKABLE TO 5 HIGH OPTIONAL BNC OF FIBER PORT 8 OR 9 PORT AND 4 OR 5 PORT PERSONAL HUBS W MAN UP LINK SW MEDIA CONVERTERS 10MB AND 100MB SERIES ALL MEDIA COMBINATIONS INCL FIBER ST SC MM SINGLE MODE THE X LINE OF CONFIGURABLE MIXED MEDIA PRODUCTS STACKABLE CONCENTRATORS SNMP OPTIONAL 13 PORTS MINI CONCENTRATORS 7 PORTS REPEATERS 2 PORTS REPEATER PORT MODULES RPMS 6 TYPES FOR ETHERNET MEDIA COAX TRANSCEIVERS 10MB SERIES Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 1 0 1 1 SPECIFICATIONS Technical Specifications Performance Filtering Forwarding Rate Ethernet 1OMb 14 880 pps Fast Ethernet 1OOMb 148 800 pps Gigabit Ethernet LOOOMb 1 488 000 pps Switching Processing Type Store and Forward with IEEE 802 3x full duplex flow control non blocking Data Rate 1OMbps 100Mbps and 1000Mbps Address Table Capacity 4K nodes self learning with address aging Packet buffer size 240KB for 10 100 and 120KB for 1OOOMb Latency 5 us packet time 100 to 1OOMbps 15 us packet time 10 to 10 Mbps and 10 to 1OOMbps Network Standards and Compliance hardware Ethernet V1 0 V2 0 IEEE 802 3 1OBASE T IEEE 802 3u 100Base TX 10OBASE FX IEEE 802 3z 1000BASE TX Ethernet Auto Negotiation IEEE 802 3ab 1OOOBASE TX
42. age 88 to 300 VDC 125VDC Input current 0 1 Amps max for all RJ 45 ports Input current 0 125Amps max for all Fiber ports Power Consumption 25 watts max for fully loaded fiber ports 24V 48V 125V DC 8 watts typical for all RJ 45 Ports B2 0 48VDC 24VDC and 125VDC POWER THEORY OF OPERATION The 48 VDC 24VDC and 125VDC power options are designed using diodes inside on each DC power input line behind the two external power connection terminals so that the power from an external source Switch can only flow into the switch This SUPPL A allows the Switch to operate only whenever DC power is correctly applied z CHASSIS to the two inputs It protects the Switch OND from incorrect DC input connections An incorrect polarity connection for example aio Bun or aia will neither affect the switch or its internal ta gt ak eee es POWER i as ae es power supply Nor will it blow the fuse in the ae 2 a aM ee internal power supply B3 0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES Magnum 6K8 Series Switches are easily installed in a variety of applications where 48VDC 24 or 125VDC or 5VDC power is used as the primary power source The DC power configuration capability DC terminal block provides an Ethernet networking solution utilizing a special power supply in switches with a proven track record 66 Magnum 6K8 Series Industrial Field Swit
43. ance LAN connections The entire network is sharing a higher bandwidth of multicast packets used for secure camera monitoring and data mining for the vital database located in a controlled center secured building The entire spread network will be manageable to provide easy detectable uninterrupted support through a viewable SNMP monitor The NEMA TS 2 and TEES along with IP53 approval with the mix of copper and fiber ports on the 6K8 Series Industrial Field Switch provides an economical and seamless solution to the requirements The user configurable Magnum 6K8 provides an extra boost to the network requirements by providing copper fiber media along with the higher bandwidth support of 10 100Mbps The user can utilize the SNMP feature equipped with 802 1Q VLAN RMON RSTP and other standard managed LAN features to provide a secure and stable network The 6K8 Series Industrial Field with S ring and Link Loss Learn feature easily fulfilled the redundancy requirement in a secure and fast reconfiguration time for cable breakup by setting up a ring topology SNMP Control Center Lo mmes gt Magnum 6K25 Interne E EEE E 7 2i TV Ll ll CCTV a A J z CCTV 23 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Fig 2 4b Magnum 6K8 equipped with S Ring in redundant ring in a outdoor Traffic application Example 3 In another example a large Power Su
44. at even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established 3 2 6 Connecting Gigabit Media Using GBICs The Gigabit ports accept industry standard GBICs for _ www GarrettCom com 29 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 user selection of the gigabit media type desired A selection of fiber and copper GBICs are available 3 3 DIN Rail Mounting The Magnum 6K8 is designed for use in a factory floor industrial environment It is available with optional DIN Rail brackets to mount it securely in a metal factory floor enclosure maintained vertically for proper convection cooling of the unit The Magnum 6K8 requires two DIN Rail mounting clips or latches for secure mounting and these may be ordered as Model DIN RAIL 6K8 See a 6K8 viewed from the rear at right with model DIN RAIL 6K8 in place on the unit The Din Rail Latching clips are mounted on the upper rear corners of the 6K8 unit Two threaded holes are provided on the sides of 6K8 for DIN Rail mounting purposes See side view at the left with the top of the unit pointed to the right The required two screws are included with the DIN Rail brackets and are no 10
45. ations applications _ ww GarrettCom com a 24 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 3 0 Installation Before installing the equipment please note the following UL CSA60950 product safety listing requirements 1 The external power supply for 24VDC units shall be a Listed Direct Plug In power unit marked Class 2 or a Listed ITE Power Supply which has a suitably rated output voltage i e 24VDC and suitably rated output current Mounting Instructions A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer B Reduced Air Flow Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not compromised C Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Appropriate consideration of equipment nameplate ratings should be u
46. bstation Electric and Gas needs a Secure Ethernet LAN network to collect monitor and provide a simplified communications backbone for local and remote control of real time operational and fault analysis data The Ethernet backbone should pass the information of SCADA local monitoring and control via a HMI The heart of the system evolves around several communications processors The Hardened enclosed 6K8 125VDC Industrial field switch with IEEE 1613 and IEC61850 approved for power stations is equipped with its modularity secured management features un controlled temp ratings along with a hardware software controlled Alarm Relay which easily qualifies it to provide all the requirements of substations The successful track record of previous members of the 6K family in sub stations also adds another example of success for this product to deploy in sub station environments The combination of 6K25 as the backbone and 6K8 at the edge provides a seamless secure solution which can easily monitor real time operations Enriched with Fiber and copper options make this switch ready to provide this solution and also control any emission noises via a fiber approach SCADA Event HMI Comm Monitor Monitor processor PIC Control Center SNMP Monitor WN 3 jena ae eee 2 Interne Comm processor A A omm i processor Comm S Comm pn processor processor Magnum 6K8 Industrial Field switch in Power Subst
47. cause the NC contacts will open when internal power is lost either from an external power down condition or by the failure of the power supply inside of the Magnum 6K8 Switch Useful info about Alarm contacts 1 There is four terminal block 1 2 3 4 provided next to AC DC power supply 2 The top two pins 1 2 are software operated 3 The bottom two pins 3 4 are hardware operated 4 By default it is NC normally closed 5 The software operation needs to be enabled and set to get the Alarm traps For detail information about the Software Alarm and software control of SNMP alarm traps please reference the Magnum MNS 6K Software User Manual Chapter 19th The Alarm Contact is on the front left area next to the DC power source of the Magnum 6K8 Series unit and is green in color as shown in the picture 35 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 3 6 6K8 Series Port Module 6KPMYV Installation Note The modules used in the 6K8 Series vertical mount unit are similar to those used in 6K16V units The modules have the letter V in the model numbers to order the right module for this unit In the Port Module materials below all modules are referred to as 6K PMV for convenience in describing port module installation Magnum 6K8 Series Switches are normally received from the factory with all required 6KPMV modules installed There may be situations where 6K PMV cards need to be added
48. ch Installation and User Guide 04 07 Figure C5 0 48VDC wiring connections to the External Terminal Block on a Magnum 6K8 48VDC The 48 VDC solution is particularly useful in the telecommunication industry where it is common for facilities to operate on 48VDC power Such companies include regular and wireless telephone service providers Internet Service Providers ISPs and other communication companies In addition many high availability equipment services such as broadcasters publishers newspaper operations brokerage firms and other facilities often use a battery backup system to maintain operations in the event of a power failure It is also frequently used for computer system backup management and Operations monitoring equipment The 24V and 125VDC options are particularly useful in the Industrial environment where it is common for facilities to operate on 24VDC or 125VDC power The 125VDC options are mainly used in power utilities such as electrical substations electrical generating plants etc The 24VDC applications are mainly in the Industrial environment such as factory floor HVAC equipment military equipment etc The 5VDC options are mainly used for military or Industrial factory floor applications B4 0 6K8 SERIES 48V 24 125 OR 5VDC INSTALLATION This section describes the proper connection of the 48VDC leads or 24VDC 125VDC S5VDC leads to the DC power terminal block on the Magnum 6K8 Series Switch The DC
49. com Email support garrettcom com Federal Communications Commission Radio Frequency Interference Statement Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his her own expense will be required to take whatever measures may be required to correct the interference Canadian Emission This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil respecte toutes les exigences du R glement sur le mat riel du Canada Cet appareil est Classe A RegulatoryUL60950 Voltage Range 18 36VDC 24vdc option 38 60VDC 60vdc option 100 I150VDC 125vdc option 100 240Vac AC option Test Temp 40 C www GarettCom con E Magnum 6K8 Series Industrial Field Switch Installation amp User Guide 04 07 Table of Contents aceron ioe Page LY SPECIFICATIONS sonein rin 2 1 1 Technical Specificati
50. cribed below Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addresses are on the same port segment will be filtered constraining them to that one port and relieving the rest of the network from having to process them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Traffic needed for maintaining the un interrupted operation of the network such as occasional multi cast packets is forwarded to all ports The Magnum 6K8 Series Switches operate in the store and forward switching mode which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network Address Learning All Magnum 6K8 Series units have address table capacities of 4K node addresses suitable for use in larger networks They are self learning so as nodes are added removed or moved from one segment to another the 6K8 Series Switch automatically keeps up with node locations An address aging algorithm causes least used addresses to fall out in favor of frequently used addresses To reset the address buffer cycle power down and up 4 2 Dual LEDs Status on TOP and Front of the 6K8 Series unit iOMb s FE is E LINK e ACT Mi 7 oe 10 100 ae fae eee 10 100 10
51. dn GarrettCom Industrial Networking at Its Best Magnum 6K8 Series Industrial Field Switch Hardware Installation and User Guide Magnum 6K8 Series Industrial Field Switch Installation amp User Guide 04 07 Magnum 6K8 Series Industrial Field Switch Hardware Installation and User Guide Part 84 00160 Rev B Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum 6K8 Series Industrial Field Switch contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum 6K8 Series Switch products consult Section 6 Troubleshooting of this User Guide Copyright 2006 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America Magnum 6K8 Series Industrial Field Switch Installation amp User Guide 04 07 Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom
52. dvanced managed network software operation at extended temperatures fiber ports modularity support for self healing ring structures redundancy security and gigabit backbone configurability The Magnum 6K8 has all of these in a very tough and robust metal case with a wide choice of popular DC options or industry standard AC internal input The plug n play Magnum 6K8 Industrial Field switches should be mounted rtically using the vertical mounting brackets which come along with the unit or by using the DIN RAIL KIT optional for Din rail mounting Loaded with versatile and secured management software MNS 6K the 6K8 switch can be easily managed and monitored via SNMP or secured Web Supporting dual Gigabit ports copper or fiber in one slot defines the Magnum 6K8 Field switches role as an effective Managed Gigabit media converter Switch that meets any secured Gigabit media requirements Dual LEDs on the front and side help the vertically mounted 6K8 to be monitored easily The modular designed Magnum 6K8 Industrial Field switch can support a maximum of two Gigabit modules fiber or copper to meet any demand of bandwidth required applications In an on going demand of diversified designed Ethernet applications the Magnum 6K8 is a fine solution to meet and satisfy any requirements through its rich modular structure The Relay contact for external ALARM is another additional _ www GarrettCom com a 10 Magnu
53. e twist lock cc eeeeeeeeeees 27 I2 Connecting Fiber Optic SC type Snap In ee eeeeeeeees 27 3 2 3 Connecting Single Mode Fiber Optic ssssssssssosooeeeeesssssssssss 2d 3 2 4 Connecting Twisted Pair RJ 45 CAT3 CATS ee 28 3 22 3 Connecting Twisted Pair CATSE or better ccceeeeeeeeeees 29 3 2 6 Connecting Gigabit Media Using GBICs snsssosssoosoeeeesessssss 29 3 3 DIN Rail MOU 109 ircaaiiarcncssncaaineyontassruanet exndntntetenats uasdwandeusncisiacanuens 30 3 3 1 Installing DIN RAIL variable brackets on Magnum 6K 8 31 3 3 2 Mounting Dimensions for 6K8 with metal brackets 33 3 4 Powering the Magnum 6K8 Series Industrial Field Switch 34 3 5 Alarm Contacts for monitoring internal power and Software Traps 35 3 6 6K8 Series Port Module 6KPMYV Installation cece 36 3 6 1 Preparation for Installing and Removing 6KPMVs from 6K8 s 36 3 6 2 Installing 6KPM Cards in the Magnum 6K8 Series 38 3 6 3 Removing 6KPM Cards iscceccscsiesscecessaieagnctgaancacnandcesseasnaaasenentannas 41 3 7 Connecting a Management Console Terminal to Magnum 6K8 42 3 7 1 RS 232 DB 9 Console Com port Serial port pin assignments 43 O COIN agar ca sasccons saeeccnsecncuceracecnsasasnesensiccevsasecasseszissasscevseassinue 43 4 1 Switching Functionality cccccccccccccccccccsssssseesseeeeeeeeeeeeeeeeeeaeeeeeeeees 43 4 2 D
54. e and return the enclosed Product Registration Card to GarrettCom Inc as soon as possible In the event there are items missing or damaged contact the party from whom you purchased the product If the unit needs to be returned please use the original shipping container if possible Refer to Section 6 Troubleshooting for specific return procedures NOTE This Hardware user manual only contains the hardware related information about the Magnum 6K8 and provides help for Network installation wiring and other hardware features Refer to our Software user Manual for management software features and configurations e g VLANS RSTP SNMP RADIUS TACACS etc using this URL www garrettcom com techsupport software userguides 6kseries_softugrel3 pdf Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 2 a Product Description Magnum 6K8 Series 6K8 The Magnum 6K8 Series Industrial Field Switch is the smallest member of the Managed 6K Switch family Itis equipped with one module slot configurable to 8 ports It is specially designed to meet industrial power substation and e AOAN x TAA outdoor Ethernet specifications while es fulfilling the needs of hardened applications 6K8 Series managed field switches provide modularity of fiber and copper ports They come with a combination of 1OMb 1OOMb and 1000Mb speed ports with comprehensive management software in a compact industrial grade package The
55. ensures that all forwarded frames are of a valid length and have the correct CRC 1 e are good packets This eliminates the propagation of bad packets enabling all of the available bandwidth to be used for valid information While other switching technologies such as cut through or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscriminate cut through forwarding is greater traffic congestion especially at peak activity Since collisions and bad packets are more likely when traffic is heavy the result of store and forward operation is that more bandwidth is available for good packets when the traffic load is greatest When the Magnum 6K8 Series Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to the devices sending packets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows a traffic catch up to occur without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a fraction of a second
56. erver in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port Extended temp ratings 24V 125VDC power supply options and IP53 approval qualifies this managed 6K8 Series switch for use in temp un controlled network floors and many others temp sensitive critical Industrial applications where above normal room temp is present in the room the network operates Full duplex future proof fiber media can easily connect long distance subnets and provide a stable secure network to all applications The SNMP QOS management capability of the Magnum 6K8 Series Switch helps create a database of all the network subnets to easily manage the network and prioritize the sensitive and useful data The Relay contact for the Alarms feature operated through software and hardware provides extra reliability to monitor the switch operation or any power failure _ www GarrettCom com 22 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Example 2 In another outdoor Ethernet Traffic monitoring application a managed network is needed to provide a redundant ring topology for a maximum redundant network This is needed where any faulty cable cable disconnection or power failure in a ring switch needs to be reconfigured in milliseconds The ring topology of the network consists of high speed LAN segments supported by 100Mbps full duplex future proof fiber media to provide secure long dist
57. es Industrial Field Switch Installation and User Guide 04 07 3 6 3 Removing 6KPM Cards To properly remove a 6KPM card from the 6K8 Series Industrial Field Switch follow the 3 steps below Step 1 Remove chassis cover See procedures in Section 3 6 1 above Caution Be sure the power cord is unplugged Step 2 Remove retaining screws placed on top of the 6K PMV and Face Plate Each 6KPMV module is secured with nine retaining screws 440x3 8 These screws are used to secure a 6KPM card in position see Figure 3 6 3a Remove the 9 screws to take off the daughter module and thereafter three standoffs underneath holding the Granddaughter board with the chassis Figure 3 6 3a 8 retaining screws shown by arrows Step 3 Remove 6KPM Card Carefully and gently pull out the daughter board from the latching connectors using both hands gripping the board near the latch up connectors as shown in Fig 3 6 3b Figure 3 6 3b Removing a 6KPM Card 4 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 All the same procedures will apply for replacing any 6KPMV module from 6K8 Series managed switches Follow the steps as described for installing a 6KPMV card discussed in step 3 7 1 3 7 Connecting a Management Console Terminal to Magnum 6K8 Use a DB 9 null modem cable use on any serial port or one DB 9 and one USB USB port on the laptop null modem cable to connect the Magnum6K8
58. et of software programs and options Magnum 6K8 Series Industrial Field Switches have heavy duty metal cases and auto ranging power supplies for operation with standard AC power worldwide Internal DC power supplies are optional All DC power input types 24V 48V 125V are supported and dual source input is optional Alarm Relay contacts provided on each Magnum 6K8 Series Switch are monitored via the hardware and software providing a loss of power signal and user defined software events through traps See Section 3 5 for details The wide selections of port modules are key to the flexibility and adaptability 2 2 la Magnum 6K8 Series Industrial Field Switch The Magnum 6K8 Series is primarily designed for use in vertical mount applications Equipped with multi media fiber copper solutions multiple speed 10 100 1000Mb support rich MNS 6K management features hardware and software alarms and _ www GarrettCom com a 9 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 convection cooling no fans the Magnum 6K8 easily qualifies for use in transportation and traffic control systems power utilities and industrial factory floors For the fast growing demands of video surveillance systems with segments requiring Gigabit backbone interconnections the Magnum 6K8 managed switches are easy to install and operate with Magnum 6K management firmware The advanced generation of industrial applications requires a
59. f the IEEE 1613 Class 2 standard GCI advises that for substation applications the serial RJ 45console_ports are intended for temporary connectivity to other equipment such as PCs Since the console port connection is temporary it is excluded from IEEE 1613 packet loss testing per the 1613 standard defined test procedure 4 0 OPERATION This chapter describes the functions and operation of the Magnum 6K8 Series Switch 4 1 Switching Functionality A Magnum 6K8 Series provides switched connectivity at Ethernet wire speed among all of its ports The Magnum 6K8 Series supports10 100Mbs for copper media and 10 or 1OOMb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance All ports can communicate to all other ports in a Magnum 6K8 Series but local traffic on a port will not consume any of the bandwidth on any other port _ www GarrettCom com 43 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Magnum 6K8 Series units are plug and play devices There is no software configuring necessary to be done for basic operation at installation or for maintenance The only hardware configuration settings are user options for an UP LINK Switch resides inside the unit on the 6K8 RJ45 Optional Half Full duplex mode and 10 or 100Mbps selection for the switched ports must be configured through MNS software per unit as per the requirement The internal functions of both are des
60. f the problem Any changes to system administration procedures should all be noted in this record Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form 63 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if GarrettCom cannot duplicate the problem or condition causing the return the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 6 4 Shipping and Packaging Information Should you need to
61. gh so the 48VDC power source must be strong enough to provide power to the 6K switch and to all the 8 RJ 45 ports with PD devices connected up to 15 watts per PoE port _ www GarrettCom com 58 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 e In the case where the 48VDC power in not internally connected and no power is coming to the PoE ports for some reason all the PoE port LEDs are ON simultaneously to indicate a trouble condition The ports will still operate properly for data traffic 5 2 11 6KP8 45 2MT 6 10 100Mbps RJ 45 and 2 100Mb multi mode FX MTRJ Small Form Factor The Magnum 6KP8 6KP8V 45 2MT eight ports Module is a 6 Port 10 10Mbps amp 2 port 100Mb Multi Mode Ag combo module with copper and fiber Small Form Factor MTRJ type ports The small sizes of MTRJ connectors give an advantage of placing more fiber ports on one module The 2 LINK 10 100 6KP8 45 2MT is equipped with six 10 100 RJ 45 ports and two ACTIVITY Q FULL HALF 100Mb MTRJ fiber ports When installed in a Magnum 6K8 Series Switch it supports the standard distances as mentioned on 5 2 3 and the LEDs also act similarly 6 Port 10 100Mbps amp 2 port 100Mbps SingleMode Ady LC 5 2 1la 6KP8 45 2LC 6 10 100Mbps RJ 45 and 2 100Mb single mode FX LC Small Form F actor The Magnum 6KP8 45SLC eight ports Module is a combo module with copper and fiber QO LINK 10 100
62. gital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage lead from 48V or 48V supply must be connected to the post labeled The connection procedure is straightforward Simply connect the DC leads to the Switch s power terminals positive and negative screws Ensure that each lead is securely tightened The 24VDC amp 125VDC terminal block on Magnum 6K8 Series s is similar to that described in the 48 VDC information above 70 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 C5 1 UL Requirements C6 0 C7 0 eS E pn The following must be adhered to in order to conform to UL requirements Minimum 18 AWG cable for connection to a Centralized DC power source Minimum 14 AWG cable for connection to earthing wiring Use only with Listed 10 A circuit breaker provided in building installation Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent Fastening torque of the lugs on the terminal block 9 inch pound max Centralized DC Power Source cable securement use at least four Minimum 14 AWG cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block ORDERING INFORMATION Optional To order the optional Dual Source 48VDC power supply factory installed order Dual Src48V
63. gle mode While connecting fiber media to SC connectors simply snap the two square male connectors into the SC female jacks of the 6PM module until it clicks and secures 3 2 3 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx _ www GarrettCom com 27 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 are the diameters of the core and the core plus the cladding respectively Single mode fiber allows full bandwidth at longer distances and may be used to connect 10 MB nodes up to 10 Km apart or 18Km with the 6K SSC The same procedures as for multi mode fiber applies to single mode fiber connectors Follow the steps listed in Section 3 2 2 above 3 2 4 Connecting Twisted Pair RJ 45 CAT3 CATS Unshielded or Shielded The RJ 45 ports of the Magnum 6K8 Series can be connected to the following two media types LOOBASE TX and 10BASE T CAT 5 cables should be used when making 1OOBASE TX connections When the ports are used as IOBASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 3 4 5 1OBASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 N
64. h ST type fiber connectors This procedure applies to ports using a 6K8 Series module MST type port 1 Before connecting the fiber optic cable remove the protective dust caps from the tips of the connectors on the PM Save these dust caps for future use 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated ports at each end of the fiber optic segment 3 Connect the Transmit TX port light colored post on the Magnum PM to the Receive RX port of the remote device Begin with the color coded strand of the cable for this first TX to RX connection 4 Connect the Receive RX port dark colored post on the PM to the Transmit TX port of the remote device Use the non color coded fiber strand for this 5 The LINK LED on the front of the PM will illuminate when a proper connection has been established at both ends and when power is ON in the unit If LINK is not lit after cable connection the normal cause is improper cable polarity Swap the fiber cables at the PM connector to remedy this situation 3 2 2 Connecting Fiber Optic SC type Snap In The following procedure applies to installations using a PM with SC type fiber connectors 1 e using 6K MSC 6K SSC sin
65. her input will not damage the Switch or power supply internally nor will it blow the fuse in the internal power supply because of the blocking action of the diodes This is true even if one input connection is reversed while the Switch is operating from the other source e The Switch will not receive power and will not work when both inputs are simultaneously absent or are both incorrectly connected C5 0 INSTALLATION This section describes the proper connection of the 48VDC 24VDC and 125VDC dual source leads to the 48VDC 24VDC amp 125VDC power terminal block on the Magnum 6Ks Switch as shown in Fig The 48VDC terminal block on the Magnum 6K8 Series Switch as shown in Fig C5 0 is located on the left front of the unit and is equipped with five 5 DC Terminal screw down lead posts The primary terminals are identified as positive A negative A and the secondary power terminals as negative B positive B The chassis earth or ground GND is a threaded post with a 6 nut The Dual Source terminal block for the 24VDC and 125VDC are similar Figure C5 0 48VDC Dual Src wiring connections to the External Terminal Block on a Magnum 6K8 48VDC Note The GND should be hooked up first The 6K8 Series unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use Before connecting hot lines to the Terminal Block of 48VDC 24VDC or 125VDC always use a di
66. hile up to two Gigabit modules maxm can be configured in the modular slot for GBPM 2OTX The Dual Gigabit port option for the modular slot provide a wide option of choice for various Gigabit transceivers covering a long range of distance The GBPM 20TX also meets the requirement for those applications where a managed Gigabit media converter is required The two Gigabit slot can be filled with copper Fiber or mix as per the application The 6K16 Series Modules provide a GBIC opening for insertion of industry standard GBICs to provide Gigabit Gb transceivers media flexibility GBIC models are available for both multi mode 550m and single mode 10 25 40 70 km fiber options and Gigabit copper as well with new models appearing often Each port has an Full and Half Duplex F H Activity ACT LED indicating packets being received and a Link LK LED indicating proper connectivity with the remote device when lit _ www GarrettCom com 61 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 5 2 14 6KM BLNK The 6K8 BLNK is a blank face plate or cover plate that must be installed in any empty 6K16 Series PM slot to maintain proper cooling air flow safety etc Two screws underneath the front panel hold the 6K8 BLNK in place 6 0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of a
67. ial Field Switch Installation and User Guide 04 07 4 6 2 6 3 If the problem is isolated to a network device other than the Magnum 6K8 Series Switch product it is recommended that the problem device be replaced with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum 6K8 Series Switch and its associated cables are functioning properly If the problem continues after completing Step 4 above contact your supplier of the Magnum 6K8 Series Switch unit or if unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance When Calling for Assistance Please be prepared to provide the following information A complete description of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components involved in the problem d Any particular application that when used appears to create the problem An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier It is useful to include other network equipment models and related hardware including personal computers workstations terminals and printers plus the various network media types being used A record of changes that have been made to your network configuration prior to occurrence o
68. ion 5 2 5a 6KP6 MTI0ST 4 100Mb multi mode FX MTRJ Small Form Factor and 2 10Mb Multi mode ST Fiber port The 6KP6 RJ1OST is a combo module with two different kinds of fiber flavor with two different speeds The top four ports of MTRJ Small form factor fiber support at 100Mb full duplex whereas the bottom two ports multi mode ST Fiber support 1OMb half duplex This combo module provides more flexibility to the user to connect their legacy 10Mbfiber as well as 1OOMb to the Magnum 6K8 Series Switch When installed in a Magnum 6K8 Series Switch the 1OOMb MTRJ connector supports fiber optic cable distances up to the IEEE standard 100Mbps distance limits 1 e typically 2km at full duplex and 412m at half duplex Thel1OMb Multi mode ST Fiber connector supports the standard fiber optic distance limit of 2Km at full and half duplex both The functionality of this OOBASE FX multi mode 4 port module is essentially the same as the ST and SC types It has the same LEDs per port indicating port activity ACT Link LK and FDX or HDX operation 5 2 6 6KP8 45MT 4 10 100Mbps RJ 45 and 4 100Mb multi mode FX MTRJ Small Form Factor The Magnum 6KP8 45MT Module is a combo module with 6KP8 45MT copper and fiber Small Form Factor 4 Port 10 100Mbps amp 4 port 100Mbps MTRJ type ports The small size of Multi Mode AS MTRJ connectors provides an ae ey advantage of placing more ports on one module The 6KP8 45MT is equipped with 4
69. ips on either side of the transceiver at the same time and pull the transceiver out Each port has an Activity ACT LED indicating packets being received and a Link LK LED indicating proper connectivity with the remote device when lit 5 2 12a GBIC LXSC Gigabit fiber 1L000Mb multi mode SC Connector The Magnum GBIC LXSC is a single mode Gigabit fiber connector equipped with SC type connectors and can be easily snapped in and out The Gigabit fiber ports are most popular as server to switch and switch to switch applications It supports cable distances up to the IEEE 802 3z gt standard 1 1000Mb Fiber SC 2 CT ko 100Mb SC TX ELK RX p i 1000Mbps distance limits i e 10 25 40 TAERA IX NRX or 60 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 70Km at full duplex and depend upon the Gigabit modules used The two Giga port has been offered as GBPM 2OTX fiber or RJ 45 whereas the single Gigabit module comes in flavor of G 4 10 100 RJ 45 ports or G 2 100Mb fiber ports as shown below in the above figure Each port has an Activity ACT LED indicating packets being received and a link LK LED indicating proper connectivity with the remote device when lit 5 2 13 GBPM 20TX Two Gigabit option The Magnum 6K16 Series offered a wide selection of Gigabit speed with multiple choice of copper or Fiber or mix for the modular slot via GBPM 2O0TX 2 x Giga module W
70. l Field Switch Installation and User Guide 04 07 5 2 3 6KP6 RJSSC 4 6KP6 RJMSSC 10 100Mbps RJ 45 Ports 4 Port 10 100Mbps and 2 100 Mb SSC Fiber Port and 2 100Mbps single mode FX SC type snap in connector The Magnum 6KP6 RJSSC is also a Combo module equipped with 4 dual speed 2 LINK 10 100 copper ports and 2 Single mode SC type connectors It 3 aie ati Q Mate provides an advantage through combining copper and Fiber functions in one module of the 6K8 Series Switch supporting four Copper and two single mode fiber network segments The 6KP6 RJSSC when installed in a Magnum 6K8 Series Switch operates on copper at the 100m distances The Fiber is single mode and cable lengths can be as much as 25 Km see Power Budget Section 4 5 Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and a FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates 100Mbps speed when lit and at 10Mbps speed when off To distinguish the single mode 6 K6 RJSSC from the multi mode 6K6 RJMSC the label Sel M is at the top of the faceplate of the 6K6 RJSSC 5 2 4 6KP6 RJSSCL 4 10 100 MB copper port and 2 100Mbps single mode FX SC type snap in connector The Magnum 6KP6 RJSSC is also a Combo module equipped with 4 dual speed copper ports and 2 Single mode Long Reach
71. lex when OFF and the blinking ACT LED indicates receiving Activity on the port A fiber cable must be connected into a SFF port and the Link LK indicator for that port must be ON indicating there is a 1 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 powered up device at the other end of the cable in order for a LK LED to provide valid indications of operating conditions on that port 2 2 3 Eight Port Copper Module 6K8 RJ45 The 6K8 Series s 8 port Copper port module model 6K8 RJ45 provides eight 10 100Mb switched RJ 45 ports The 10 100Mb switched ports normally as a default setting are independently N way auto negotiating and auto crossover MDIX for operation at 10 or 1OOMb speed in full or half duplex mode 1 e each independently selects a mode and speed to match the device at the other end of the twisted pair cable See Section 4 3 for auto negotiation and MDIX details The auto crossover feature will automatically determine the other side of connection to make the connection and eliminate the need of crossover cable On the model 6K8 RJ45 module there are four LEDs for each port two in the connector and two separate The LK Link LED indicates ready for operation on that port when lit The blinking ACT Activity LED indicates receiving Activity on that port when lit The 10 100 LED indicates operation at 100Mb speed when ON and at 10 MB speed when OFF when auto nego
72. m 6K8 Series Industrial Field Switch Installation and User Guide 04 07 feature which allows the Magnum 6K8 to monitor the internal power failure and controlled via hardware or software trap controls The options for universal AC and 24V 48V 125VDC power options offer a widely accepted managed switch with high reliability 2 2 2 Eight port SFF fiber modules 6K8 MTRJ 6K8 MLC 100Mb fiber 5 7i ACT 00 Fig 2 2 2 ACT SFF Fiber Port Modules F H T mT Tw EEE EE 6K8 MTRJ to the left LILIJCICI and g Q TLK FK 6K8 MLC or SLC below In an eight port SFF fiber port module all of the fiber ports are of the same speed 100Mb mode and connector type Models available with Small Form Factor SFF are multi mode MT RJ or LC type connectors and single mode LC type connectors The 100Mb fiber eight port modules for the Magnum 6K8 Series H C a o normally are set factory default to R Hii operate in full duplex mode forest os a i ik rm fe Px g fiber distance and performance Using AIR g BLK the 6K MNS software the user may select full or half duplex mode per port through set up of the software See Magnum 6K MNS Software Manual for the flexibility to adapt to any FDX or HDX type of Fast Ethernet devices There are three LED s per fiber port The Link LK LED indicates ready for operation on that port when lit the F H LED indicates operation in full duplex mode when ON half dup
73. m 6K8 Series Switches incorporate a flow control mechanism for Full Duplex mode The purpose of flow control is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full This is most likely to occur when data is moving from a 100Mb port to a 10 MB port and the 10Mb port is unable to keep up It can also occur when multiple 100Mb ports are _ www GarrettCom com 46 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 attempting to transmit to one 100Mb port and in other protracted heavy traffic situations Magnum 6K8 Series Switches implement the 802 3x flow control non blocking on Full Duplex ports which provides for a PAUSE packet to be transmitted to the sender when the packet buffer is nearly filled and there is danger of lost packets The transmitting device is commanded to stop transmitting into the 6K8 Series Switch port for sufficient time to let the Switch reduce the buffer space used When the available free buffer queue increases the Switch will send a RESUME packet to tell the transmitter to start sending the packets Of course the transmitting device must also support the 802 3x flow control standard in order to communicate properly during normal operation Note When in Half Duplex mode the 6K8 Series Switch implements a backpressure algorithm on 10 100 MB ports for flow control That is the switch prevents frames from ente
74. multi mode LC small form factor 56 5 2 9 6KP8 RJ45 Twisted Pair 10 100Mb 8 Port ossee 57 5 2 10 New PoE Power Pass through model 10 100Mb 8 port 58 5 2 11 6KP8 45 2MTmulti mode FX MTRJ Small Form Factor 59 5 2 lla 6KP8 45 2LC single mode FX LC Small Form Factor 59 5 2 12 GBIC SXSC Gigabit fiber 1LOOOMb SC Connectot 60 5 2 12a GBIC LXSC Gigabit fiber LOOOMb SC Connector 60 5 2 13 GBPM 20TX Two Gigabit Option cccc cece cece cece ee enees 59 D214 OIRIMEBINR chess nisotieannedenssniiotiedsiesenbsan dacs iunedenssandaoubdeledonssancieneles 62 60 TROUBLESHOOTING oe iaaa 62 6 1 Before Calling for Assistance sixi ssc ivesdasesdcsnndesensvcneuddiatsubonteceubaiaadehenss 62 6 2 When Calling for Assistance c c csccsseeeccceceecceeceaeeeesesseseeeeeeeess 63 6 3 Return Material Authorization RMA Procedure cccceecc ees 63 6 4 Shipping and Packaging Information ccceccccecceeeesssseseeeeeeeeeeees 64 APPENDIX A WARRANTY INFORMATION ccccccssssssscssscsssscsees 65 APPENDIX B Internal DC Power Supply Options cccccccccccsccceees 65 APPENDIX C Internal DC Dual Source Power Option 000000e 68 Revisions Rev B 06 07 small update of the DC power supply options Rev B 05 07 Update to Agency Approvals and notes on Power Substations Rev A 04 07 Minor update as per UL Rev A
75. nd needs to be mounted vertically with airflow space in the front rear and sides Fig 3 3 Magnum 6K8 mounted vertically with DIN Rail brackets and latches The DIN Rail mounting brackets and latches are optional and need to be ordered as separate items e g Model DIN RAIL 6K8 3 3 1 Installing DIN RAIL variable brackets on Magnum 6K8 Magnum 6K8 Din Rail kit comes along with the following BOM Item Quantity Description 1 1 DIN Rail Clip assy 2 2 10 32 x Phillip Flat head screws with undercut 3 8 4 40 x 3 8 Phillip Flat head screw Din Rail kit Installation procedures 1 Remove the back plate from Magnum 6K8 UNIT a There are eight screws along the edge of the unit to remove b Do not re use the old screws 2 On the back plate a Locate the indented side with 1 lees b 1 indentation signify center of the mounted Din Rail clip location c Each indented locations 1 11 111 are inches apart from the center Fig 1 3 Select the height position via indented side marking 4 Place the DIN Rail Clip assembly _ www GarrettCom com 31 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 under indented side of the plate Place two of the screws came along the kit 10 32 x 4 Phillip Flat head screws with undercut onto the indented side and screw tight the assembly as shown in Fig 2a Note Make sure the screws must have the 5lbs in torque minimum a The Din
76. ng secure VLAN performance upgrades to departmental networks and stream traffic for VOIP and audio video applications for a diversified combination of mixed media for monitoring and signaling in Industrial floor applications The performance characteristic of the 6K8 Series Switches enable them to inter connect a series of subnets one subnet per 6K8 Series Switch port in a LAN traffic center The subnet connections may be via fiber or twisted pair cabling 1000Mbps 100Mbps or 10 Mbps speed and full or half duplex The mixed media modular capability is ideal for Industrial applications where existing Ethernet LAN network cabling must be accommodated The fiber built in media capability is ideal for integrating future proof fiber cabling into the LAN structure Example 1 Magnum 6K8 Series Switch for an Industrial application Equipped with lots of useful features such as a hardened Industrial enclosure a wide spread of AC DC power supply options extended temperature rating and secured management features qualifies the Magnum 6K8 Series Managed switch for any Industrial factory floors traffic control transportations systems monitoring and signaling and power utilities applications The bundle of MNS 6K software operated features diversifies this managed switch to operate and perform securely and reliably in all critical applications The addition of the S Ring and Link Loss Learn software feature allows this Managed switch to provide a very
77. nnectors for RS 232 null modem connection sometimes called an X modem cable used to connect a PC or a character terminal to the Management port CONSOLE USB Industry standard serial cable DB 9 connectors for RS 232 null modem connection sometimes called an X modem cable to connect to a managed switch and a USB port to connect to a PC GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 2 0 Introduction 2 1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product notify the carrier of any damage that you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 Magnum 6K8 Series Industrial Field Switch base unit configured with user selected port module options installed 1 AC Power Cord U S and other 115 VAC only if AC version 1 Set of two metal vertical mounting brackets with screws to the case 1 Installation and User Guide this manual 1 Product Registration Card Remove the items from the shipping container Be sure to keep the shipping container should you need to re ship the unit at a later date To validate the product warranty please complet
78. ons cccscsseseecccececcecceaaaaeesssseeeeeeceeeeeeeeeeeeeaaas 2 1 2 Ordern Informa ON iseer EE ANE T EE ATE 5 20 IMC OU NoD sesa 7 2l Inspecting the Package and Product cc csscsssssseeeeeeeeeeeeeeeeeeeeeeaas 7 2 2 Product Description Magnum 6K8 Series 6K8 ccccceceeessees 8 2 2 la Magnum 6K8 Series Industrial Field Switch 0 eee 9 222 Eight port SFF fiber modules 100Mb fiber seese 1 223 Eight Port Copper Module 6K8 RJ45 0 0 ceseeeeeeeseeeeeeeeees 12 2 2 4 S1x Port 4 2 Combo Modules fiber ST or SC ee 13 2 2 5 New PoE Power Pass through model P6KP8 RJ45 MDIX 14 2 2 6 Four Port 10 MB and 1OOMb mm Fiber ST Modules 14 227 Gigabit LOOOMbps port modules eccccceseeteeeeeeeeeeees 15 2 2 a GBPM 20TX Two Gigabit port Option cc ceccceeeeeeees 16 2 2 8 Packet Prioritization 802 1p QOS cccsssssssssseseseseeeeeeeeees 17 220 Frame Buffering and Flow Control cccccccccsssssseeseseeeeeeeeees 18 2 2 10 Managed Network Software MNS 6K for 6K8 Series 18 2 Foar s and BONGI S sates aani aE EAEN 19 De POPC AUIONIG eira siete eutatecueuis ubnanenuandaacouecbenenoscosesdanedantes 21 30 SCAN Om sia 25 3 1 Locating Magnum 6K8 Series Switches ssceeceeeeeeeeeeeeeeeees 26 3 2 Connecting Ethernet Media cc cecesssssssseeeceeeeeceeeeaaeeeessseeeeeeeeeees 26 3 2 1 Connecting Fiber Optic ST typ
79. or replaced In cases where additional 6KPMV cards are needed the faceplate for an available front mounted slot must be removed The following procedure describes this operation The pictorial view of the hardware assembly can be seen here http www garrettcom com Pictorial 6k8_pictorial pdf 3 6 1 Preparation for Installing and Removing 6KPMVs from 6K8 s STOP Be sure the power cord is unplugged from the chassis before attempting to remove and or replace any PM cards Failure to do so may result in damage to the unit and will void the warranty Caution Opening of the 6K8 chassis can only be performed by trained service persons Avoid Static Discharge The port modules like most electronic equipment are sensitive to static discharge Use proper ESD measures when handling port modules Step 1 Make sure the 6KPMV Card package has all necessary accessories and use the proper tool to install it properly Each 6K PMV Card package for field installation contains Daughterboard Bigger and Granddaughter board smaller three 5 8 stand offs for Granddaughter board 6 standoff for daughter Board nine 4 40x3 8 Pan Head screws along with Front panel face plate package NOTE Every 6KPMV Card package comes with their matching Daughter and Granddaughter board The copper 6KPMV card should not work properly if mixed with other Fiber combo 6KPMV card packages Always install the PM module separately one by one to avoid the mixing
80. ounted using the brackets turned outside normal or inside if space is tight Attach the mounting bracket either outside or inside as shown in the illustration above dotted line shown for the brackets inside The spacing for the mounting screws into the supporting wall or panel is a rectangle 11 89 x 7 85 center to center 3 4 Powering the Magnum 6K8 Series Industrial Field Switch The Magnum 6K8 Series Switches incorporate an internal universal power supply and have a recessed male IEC connector for the AC power cord at the left rear A manual power ON OFF switch is adjacent A six foot 115 VAC 60 Hz standard power cord is supplied with each unit shipped within the United States and Canada The auto ranging power supply supports installation environments where the AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz The 16 port units will consume over 20 watts of power typically When connecting the _ www GarrettCom com 34 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Ethernet cabling there is no need to power down the unit Individual cable segments can be connected or disconnected without concern for AC power related problems or damage to the unit Power supply options are available to suit the 6K8 Series Switches to special high availability communications and or heavy industrial grade applications including 48VDC 24VDC and 125VDC with single DC input
81. port supports fiber optic cable distances up the IEEE standard 100Mbps distance limits 1 e typically 2km at full duplex and 412m at half duplex Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates the speed if the LED is ON 100Mbps if it is OFF 10Mbps 5 2 la 6KP6 RJ10ST 4 10 100Mbps RJ 45 and 2 10Mb multi mode FX ST twist lock Combo Module The 6KP6 RJIOST is a six port combo module that looks similar to the 1OOMb combo module with the exception of 1OMb speed at the ST fiber module The ST connector functions as a fiber optic transceiver to support 1 OBASE FX network segments When installed in a Magnum 6K8 Series Managed Switch the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up the IEEE standard 10Mbps distance limits 1 e typically 2km at full duplex and half duplex Each port has an Activity ACT LED indicating packets being received a _ www GarrettCom com 50 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Link LK LED that indicates proper connectivity with the remote device when lit and FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates the speed if the
82. r and 100Mb Full duplex for the 1OOMb fiber The 1OMb ST fiber ports allow the user to connect their legacy 10Mb network to the Magnum 6K8 Series switch They also provide a convenient way for the half duplex hub to connect to the switch through 10Mb fiber ports Whereas the 100Mb ST fiber module allow to connect the 1OOMb demand of Switch devices It supports distances according to the 10Base FL standard 1 e 2Km distance for multi mode fiber Single mode for 10Km distance may be available as a special order Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and FDX HDX LED indicating full duplex mode when lit or half duplex if off 5 2 2 6KP6 RJMSC 4 10 100Mbps RJ 45 and 2 100Mb multi mode FX SC snap in Fiber connector The Magnum 6KP6 6KP6 RJMSC RIMSC is also a Combo 6 Port 4 Port 10 100Mbps and 2 100 Mb SC Fiber Port module equipped with 4 10 100Mb RJ 45 ports along with 2 multi mode 100Mbps fiber optic transceivers all in one module This is similar to the 6K6 RJMST It has the same LEDs indicating port 3 ACTIVITY 4 FULL HALF activity ACT Link LK and FDX HDX and 10 100 operation and the same faceplate lettering While the functionality of these two modules is essentially the same the 6KP6 RJMSC is equipped with an SC type snap in connector instead of an ST type 52 Magnum 6K8 Series Industria
83. reliable highly available redundant network capability in any ring topology network In an Industrial environment where the factory floors are networked with Ethernet based mixed media LANs and equipped with PLC computers to take readings and data from M C Client Server databases and transport this important data to the central office data warehouses the Managed 6K8 Series shines The Managed 6K8 Series s modularity along with MNS 6K management software features handle these _ www GarrettCom com 21 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 kinds of networks very securely and reliably through out the Factory floors The DIN Rail Mounting options on the Magnum 6K8 allow the Industrial Factory floor user to mount the 6K8 securely anywhere on their Network setup The option for setting the ports at 10 or 100Mb on copper and supporting the 10 or 1OOMb fiber media provide widespread options to the users to mix and match their legacy and advance network needs The modularity of the 6K8 Series Industrial Field Switch makes it an attractive choice for use in applications with LAN connections to an organization s multiple site offices and factory floors The different locations can be easily connected together with the Fiber ports supported by the Magnum 6K8 Series Magnum 6K25 Interne Magnum 6KS8 in a Industrial floor application to monitor and signaling PLC units Switch A main NT s
84. rettCom GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty Please complete the warranty card as this acts as a product registration and mail it to GarrettCom within two weeks of your purchase APPENDIX B Internal DC Power Supply Options B1 0 SPECIFICATIONS FOR MAGNUM 6K8 SERIES SWITCHES DC POWER Magnum 6K8 Series models for 48V and 24V DC amp 125VDC Power input Each Magnum Model 6K8 Series Managed Switch DC option requires a DC power source for 24VDC 48VDC and 125VDC option power input The wide range of power input qualifies this product for use in 24VDC 48VDC as well as 125VDC environments The 24VDC 48VDC or 125VDC power input provides an Ethernet networking product utilizing a special type of power supply with a proven high reliability record to fulfill the DC requirement _ www GarrettCom com a 65 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 99 66 99 DC Power Terminals internally floating GND Terminal for earth or ground wire connection to the 6K8 Series chassis Input Voltage 18 to 36 VDC 24VDC Input current 0 6Amps max for all RJ 45 ports Input current 1 2Amps max for all Fiber ports Input Voltage 36 to 70 VDC 48VDC Input current 0 4Amps max for all RJ 45 ports Input current 0 7Amps max for all Fiber ports Input Volt
85. ring the device by forcing a collision indication on the half duplex ports that are receiving This temporary collision delay allows the available buffer space to improve as the switch catches up with the traffic flow The flow control option may enable disable through setport command of MSN 6K software as per the requirement of network By default the Flow control is disabled 4 5 Power Budget Calculations for Magnum 6K8 Series PM s with Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power Budget Py min Pp min where P Transmitter Output Power and Pg Receiver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um Mm is 2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km and the Cable Loss for 9 125 Single mode is 0 4 dB km LXSC25 and the Cable Loss for 9 125 Single mode is 0 25 dB km LXSC40 and the Cable Loss for 9 125 Single mode is 0 2 dB km LXSC70 The following data has been collected from component manufacturer s Agilent s and Lucent s
86. rk of 1OMb requirement in the network Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and a FDX HDX LED indicating full duplex mode when lit or half duplex when off The 10 100 LED indicates the speed for the copper port which is 10Mbps when the LED is ON and 10 MB when the LED is OFF 5 2 5 6KP8 MTRJ 8 100Mb multi mode FX MTRJ Small Form factor Magnum 6KP8 MTRJ is a multi mode fiber optic 8 port module equipped with a small form factor MTRJ type OKPS MTR Som all form factor 8 Port 100Mbps Multi Mode Fiber port connector It looks almost like an RJ 45 port but it is black in color The MT RJ s small size C and ease of connection make it 1 3 5 7 a good choice for 100Mbps a L L Ld Aer LKO Irk O Lk Ne fiber to the desktop Ethernet F N connectivity When installed in if LKB Gi GO uw oO IK if a Magnum 6K8 Series Switch ACTIVITY 2 it supports fiber optic cable Q FULL HALF distances up the IEEE standard LINK 100Mbps distance limits 1 e typically 2km at full duplex and 412m at half duplex 54 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 The functionality of this 1 OOBASE FX multi mode 8 Port modules is essentially the same as the ST and SC types It has the same LEDs per port indicating port activity ACT Link LK and FDX or HDX operat
87. s the same as the other 6K8 Series modules The fiber ports support fiber cabling distances according to the IOBASE FL and 1OOBASE FX standards i e 2km distance for multi mode fiber Single mode for up to greater distance may be available as a special order request quote 2 2 7 Gigabit 1000Mbps port modules The Magnum 6K8 Series offers a wide range of optional Gigabit modules and one or two Gigabit ports can be configured in one modular slot The Gigabit modules are the two ports GBPMV 2O0TX the 6KP5V G4RJ single Gigabit 4 10 100 RJ 45 ports or the 6K P3V G2SC single Gigabit 2 100Mb fiber ports as shown below in the figure E ko TX BLK RX r j ACT I9 P TXE RX 1 1000Mb Fiber SC 2 100Mb SC 1 1000Mb Fiber SC 4 10 100Mb The 6K8 Series Modules provide a GBIC opening for insertion of industry standard GBICs to provide Gigabit media flexibility GBIC models are available for both multi mode 550m and single mode 10 25 40 70 km fiber options Gigabit copper is also available with new models appearing often The 1000Mb Gigabit fiber port modules on the Magnum 6K8 Series are normally set factory default to operate at AUTO mode for best fiber distance and performance The 1000Mbps SC fiber optic module on the Gigabit SX and Gigabit LX transceivers are compatible with the IEEE 802 3z Gigabit standards There are two LEDs mounted on each Gigabit port module The Gigabit fiber port is by default configured
88. sed when addressing this concern E Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips F Replacement of fuses should be only by qualified service personnel G A readily accessible disconnect device shall be incorporated in the building installation wiring H When connected to a 48 V centralized dc source this product is to be installed only in Restricted Access Areas Dedicated Equipment Rooms Electrical Closets or the like and shall be provided with a Listed 5 A DC fuse or circuit breaker in the supply circuit This section describes installation of the Magnum 6K8 Series Switches as well as connection of the various Ethernet media types _ www GarrettCom com 25 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 3 1 Locating Magnum 6K8 Series Switches For vertical panel mounting and wall mounting see Section 3 4 For vertical DIN Rail mounting see Section 3 3 For DC power options see Appendix B For Dual Source see Appendix C For AC power input locate an AC receptacle that is within six feet 2 meters of the intended Magnum 6K8 Series site The rugged metal case of the Magnum 6K8 Series will normally protect it from accidental damage in a lab or workplace setting Maintain an open view of the front to visually monitor the status LE
89. ship the unit back to GarrettCom please follow these instructions 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 64 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification not by Gar
90. t Two separate sources each at 36 70 VDC Power Supply Internal 24VDC Dual Source model Dual Src 24V DC Power Connector First Source A ihe 2nd Source B B GND Terminal for earth or ground wire connection to the hub chassis Input Two separate sources each at 18 36 VDC Power Supply Internal 125VDC Dual Source model Dual Src 125V _ www GarrettCom com a 68 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 DC Power Connector First Source A HAs 2nd Source B B GND Terminal for earth or ground wire connection to the hub chassis Input Two separate sources each at 88 300 VDC With the exception of the dual DC input power connections and the power supply all specifications and configuration options for the Magnum 6K8 Series 48 VDC 24VDC and 125VDC models with this Dual Source option are identical to those listed in the Magnum 6K8 Series Fiber Switches Installation and User Guide including Appendix B Internal DC Power Supply Option C2 0 MAGNUM 6K8 SERIES with 48VDC 24VDC and 125VDC Dual Source option OPTIONAL The 6K8 Series Switch models with the internal 48 VDC 24VDC and 125VDC Dual Source power supply are designed for installations where a battery plant is the power source and where two separate power sources are utilized in order to increase operational uptime and to simplify maintenance The functionalit
91. ter board and a latch _ www GarrettCom com 38 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 connector to hold it securely Fig 3 6 2c Granddaughter Board placed in slot amp secured with three 5 16 standoff s Step 3 The figure here illustrates the basic layout of an individual PM card Each 6KPM card fits into the space provided on L m ri nAi E a i aN gaiil T the main board Fig 3 6 2d Daughter Board top view of 4 copper 10 100 ports Fig 3 6 2e Daughter Board shown upside down with two j ieee FFT 2i a d male latch connectors Bg pe ves a id ai Step 4 Hold the daughter board with both hands at the end and insert the 6KPMV module inside the front faceplate slot carefully Then align the two cream color latching connectors male placed at the bottom of the daughter board with the other female connector placed on the Granddaughter and main board As shown below in Fig 3 6 2f Fig 3 6 2f Magnum 6KPM daughter board aligned with the bottom latch connector after inserted properly in front plate slot Step 5 Once the latching connectors are aligned properly and the mounting holes are aligned with stand offs then _ ww GarrettCom com a 39 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 press slowly and firmly with two fingers as shown below in Fig 3 6 2f on the top of the latching connectors until the
92. tiation is not disabled The FDX HDX LED is ON to indicate full duplex operation and OFF to indicate half duplex mode A twisted pair cable must be connected into an RJ 45 port and the Link LK indicator for that port must be ON indicating there is a powered up device at the other end of the cable in order for a LK LED to provide valid indications of operating conditions on that port Using the 6K8 Series MNS 6K management software the user may disable auto negotiation and fix the desired operation of each RJ 45 port User may select 1OMb or 1OOMb speed and full or half duplex mode per port as per user requirement See Magnum MNS 6K Software Manual for details info 12 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 2 2 4 Six Port 4 2 Combo Modules 4 10 100 RJ 45 and 2 100Mb fiber 4 RJ 45 2 100Mb ST or SC The combo six port modules are combinations of copper and fiber media available as four 10 100 switched RJ 45 copper ports and two 100Mb switched multi mode fiber in either ST SC single mode SC or Long Reach SC ports For port numbering ports 1 3 5 7 are copper ports 2 and 6 are fiber and ports 4 and 8 are not present The four RJ 45 ports operate just like the 8 port copper module with auto cross MDIX features to eliminate the use of crossover cables The two fiber ports operate at 100Mbps full duplex default User mode control per port through the MNS software is
93. to AUTO mode and can be fixed at 1OOOMbps speed full duplex mode at any time The Gigabit fiber port has LEDs that indicate LK Link status and ACT receiving activity on that port when lit _ www GarrettCom com 15 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 NOTE For detail information about the various port module 6KPMV options being used for Magnum 6K8 please check section5 2 6KPM Module Description 2 2 a GBPM 20TX Two Gigabit port option The Magnum 6K16 Series offered a wide selection of Gigabit speed with multiple choice of copper or Fiber or mix for the modular slot via GBPM 20TX module While up to two Gigabit modules maxm can be configured in the modular slot for GBPM 20TX The Dual Gigabit port option for the modular slot come in couple of different configuration to provide a wide option of choice of various Gigabit transceivers covering a long range of distance The GBPM 2O0TX also meets the requirement for those applications where a managed Gigabit media converter is required The two Gigabit slot can be filled with copper Fiber or mix as per the application 16 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 Model GBIC Description One 1000BASE SX GBIC SXSC port with multi mode SC fiber connector One 1000BASE LX LH GBIC LXSC10 port 1310nm single mode SC 10Km One 1000BASE LX LH GBIC LXSC25 port 1310nm single mode SC
94. ty ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit a FDX HDX LED to indicate full duplex mode when lit or half duplex when off and a 10 100 LED indicating 100Mb when lit or 10 Mbps when off Important Note The 10 100 RJ 45 ports are supported with Auto negotiation and Auto crossover MDIX which allow the RJ 45 ports to automatically Link with any RJ 45 device and eliminate the use of crossover cable NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6KS It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce kigh greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The 6KS passes the 1613specifications for zero packet loss with fiber ports amp with RJ45 ports used as indicated here _ www GarrettCom com 57 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 5 2 10 New PoE Power Pass through model P6KP8V RJ45 MDIX 10 100Mb 8 port 6KP8 45R1 The 8 Port 10 100Mhb Conner ports PoE RJ 45 ports act similar to regular
95. ual LEDs Status on TOP and Front of the 6K8 Series unit 44 www GarettCom com E Magnum 6K8 Series Industrial Field Switch Installation amp User Guide 04 07 4 3 Auto Cross MDIX and Auto negotiation for RJ 45 ports 45 4 4 Flow control IEEE 802 3x Standard cee ceeceeccecceccecceecesceecs 46 4 5 Power Budget Calculations for 6K8 Series PM s with Fiber Media 47 5 0 Introduction Magnum 6K8 Industrial Field Switch Port Modules49 5 1 Inspecting the Package and Product cc ceeesssssesseseeeeeeeeeeeeeeeenaes 49 52 OKPMY Module Description sicsincsvccostscsstastcavecrsecerecancteussdetwlavesenseaneds 49 5 2 la 6KP6 RJIOST multi mode FX ST twist lock Combo Module50 5 2 1b 6KP4 F10ST 4 10Mb multi mode FX ST twist lock Module51 5 2 lc 6KP4 FLSTFX 2 10Mb amp FX ST twist lock Module 51 5 2 2 6KP6 RJMSC multi mode FX SC snap in Fiber connector 52 5 23 6KP6 RJSSC Ports single mode FX SC type snap in 53 5 2 4 6KP6 RJSSCL single mode FX SC type snap in connector 53 5 2 4a 6KP6 RJIOST multi mode FL ST type twist lock connector54 5 2 5 6KP8 MTRJ 8 100Mb multi mode FX MTRJ Small Form factor54 5 2 5a OKP6 MTIOST Multi mode ST Fiber port cc ccecceeeeeeeeees 55 5 2 6 6KP8 45MTmulti mode FX MTRJ Small Form Factor 55 32 7 6KP8 MLC multi mode LC connector Small Form Factotr 55 5 2 8 6KP8 45LC Combo
96. wer input is 48VDC Magnum 6K8 125VDC Same as 6K8 except the power input is 125VDC Configuration Options Each Magnum 6K8 base unit has one port module slot which can be equipped with one of the following single or multi mode fiber copper 1000 100 or 1OMbps modules Magnum 6K8 Port Modules 6KP8V RJ45 TP Module with 8x10 100Mbps auto negotiating RJ 45 ports 6KP8V MTRJ SFF Fiber modules with 8x100Mb mm FX MT RJ connectors 6KP8V MLC SFF Fiber modules with 8x 100Mbps mm FX LC connectors 6KP8V SLC SFF Fiber modules with 8x100Mbps single mode FX LC connectors 6KP4V FXSC 2 2 100Mb Fiber module with 4x 100Mb 2km FX SC connectors 6KP4V FXST 2 2 100Mb Fiber module with 4x100Mb 2km FX ST connectors 6KP4V F10ST 2 2 10Mb Fiber module with 4x10Mb 2km FL ST connectors 6KP4V FLSTFX 2 2 ST Fiber module with 2x100Mb amp 2x10Mb ports 2km 6KP8V 45 2MT 6 2 module with 6xRJ 45 ports and 2x100Mb 2km FX MTRJ 6KP8V 45 2SLC 6 2 module with 6xRJ 45 ports and 2x100Mb s m 15km FX LC 6KP8V 45MT 4 4 module with 4xRJ 45 ports and 4x2km mm FX MTRJ 6KP8V 45MLC 4 4 module with 4xRJ 45 ports and 4x2km mm LC connectors 6KP8V 45SLC 4 4 module with 4xRJ 45 ports and 4x2km single mode LC 6KP6V RJMST 4 2 module with 4xRJ 45 ports and 2x2km mm FX ST 6KP6V RJMSC 4 2 module with 4xRJ 45 ports and 2x2km mm FX SC 6KP6V RJSSC 4 2 module with 4xRJ 45 ports and 2x20km single mode FX SC 6KP6V RJSSCL
97. y design for Industrial Ethernet and un controlled temp operation Fiber ports take more power than copper ports but the Magnum 6K8 Series design provides for this with heavy duty components The ambient temperature dual rating is 60 C per UL methods and 95 C per type test methods E MNS 6K licensed Network Management Software included S Ring optional Release 3 1 2 fall 05 includes SNMP Switch Management with secure access control RMON CLI Port Security Port Mirroring Port Settings Control Telnet TFTP FTP support Spanning Tree Protocol Link Loss Learn S Ring with license key multi level QoS Port and tag based VLANs GVRP IGMP Snooping SNMP GUI support Event Log SNTP client for time of day BootP and DHCP client for IP configuring and password security Secured Web Management RADIUS X and TACACS MNS 6K software is factory installed supported and updated via Internet and GCI FTP Server _ www GarrettCom com 20 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 2 4 Applications Magnum 6K8 Series Fiber Switches offer high performance modularity and higher availability to provide an effective solution for Industrial Ethernet needs They provide the flexibility of 1OOMbps fiber and copper ports as well as single or dual Gigabit 1000Mb ports with industry standard MNS 6K software Magnum 6K8 Series Switches are easily used in a variety of applications including client server computi
98. y of the Magnum 6K8 Series Switch 48 VDC 24VDC and 125VDC Dual Source Option units is identical to the standard AC powered models Refer to the main sections of this Installation and User Guide for a detailed description of the Magnum 6K8 Series Switches C3 0 DUAL SOURCE OPTION THEORY OF OPERATION The Dual Source DC power option is designed using diodes inside of the chassis on each DC power input line A diode is placed in each of the four input lines behind the four 2 2 re external power connection terminals so that power from an external source can only flow into the unit This allows the unit to operate whenever DC power is correctly applied to either or both of the two inputs C4 0 FEATURES AND BENEFITS OF THE DUAL SOURCE DESIGN a The Switch unit can receive power from either input A or B The hub will normally draw its power from the DC source with the highest voltage at a given time b The Switch unit will not allow power to flow from a higher voltage input to a lower voltage input i e the two DC power sources are not mixed together by the hub c When one correct DC input is present the Switch will receive power if the other DC input is _ www GarrettCom com a 69 Magnum 6K8 Series Industrial Field Switch Installation and User Guide 04 07 absent or even if it is connected with reverse polarity or shorted or grounded d Reverse polarity connections if they should accidentally occur on eit
Download Pdf Manuals
Related Search
Related Contents
HQ Power LED QUAD FLOWER Creating Subcircuits and Hierarchal Blocks in LT Spice plaquette de programmation VM 430 - Domyos in PDF - RPA Redut Ltd. • Préparation équilibrée d`azote uréique et nitrique contenant 52 % d 取扱説明書|BCブースター BCB33N:マスプロ電工 Manual - Omega Bio-Tek QuartzWeb User Guide IV Report Submission Copyright © All rights reserved.
Failed to retrieve file