Home

Industrial Hygiene Vibration Monitor

image

Contents

1. Configured as a complete system including everything from sensors to software the IHVM 100 comes with everything needed to confidently generate meaningful exposure documentation From mechanical hand arm adapters that locate the sensors properly in relation to the operator s grip of the tool or a seat pad accelerometer for measuring Whole Body vibration you ll have all the right bits and pieces to make measurements accurately and consistently What s more with Blaze software you ll have a simple means of controlling the instrument and analyzing the resulting data To increase user friendliness the IHVM 100 comes standard with up to four out of eight possible language options including Italiano Espanol and Deutsch Any way you say it the IHVM 100 is the best solution for Safety and Health professionals when it comes to vibration exposure monitoring Glove Transmissibility How to know if your PPE is doing its job Only Larson Davis offers a unique Palm Adapter that locates a sub miniature tri axial accelerometer Sensor in a specially designed cup This cup fits unobtrusively in the worker s palm and can measure the vibration levels with and without a vibration damping glove in place thus providing you real data on how well your PPE is working Supported by BLAZE Application Software Blaze Novaprod Industries 1 Ape E aut Novaprod blz 1 OA TAS 11 20 44 to dai 799 1 i s l Se g Jaton Ca
2. LA praa ool Lrg taedia Hah Ir a 1 taedia Hah 07 111 2S mam ferret nt Edit Time History Data i BLAZE is the Industrial Hygiene and Safety Professional s analysis package of choice combining ease of use with powerful analysis and reporting capability BLAZE makes gathering and managing your vibration exposure data an absolute breeze Combining summary data and a concise color graph of the vibration levels over time on just one page you can easily present reports that are clear and understandable by workers and management alike The ability to present detailed time history reports and labeled graphs in addition to the summary reports gives even more presentation options Blaze makes instrument calibration setup and deployment a snap no need to press any keys if you prefer simply create and store multiple setup files in a Blaze library to cover all your possible measurement applications Blaze even stores individual calibration data on all your accelerometers and makes changing from Hand arm to Whole body measurement setups effortless and foolproof And for those who do noise exposure monitoring you ll be glad to know Blaze supports the Larson Davis Spark series personal noise dosimeters Contact your Larson Davis representative for info About Human Exposure to Vibration in the Workplace Risks to workers from exposure to high levels of vibration include decreased performance and even permanent inju
3. ENO26 CBL _Triaxial palm accelerometer 10 mV g ICP amp ICBLIZ5 _ _ISENO27 CBL Seat pad accelerometer triaxial amp ICBLI22 _ SWW_BLAZE Dosimetry software for IHVM100 and Spark family instruments Available Configurations IHVM100 L X NOTE X denotes LANGUAGE OPTION Select from L1 L2 L3 or L4 below OPTION L1 English Spanish German and Italian OPTION L2 English German Portuguese and Czech OPTION L3 English German Italian and French OPTION L4 English German Dutch and French IHVM100 L X HA Same as IHVM100 L X plus one each IHVM100 HA Hand Arm filter option ADPO60 Hand accelerometer adaptor T bar IADP061 Handle accelerometer adaptor straight bar ADP062 Clamp accelerometer adaptor mounting block with clamp NOTE Sensor and cable must be purchased separately IHVM100 L X HAGT Same as IHVM100 L X plus one each IHVM100 HA Hand Arm filter option IADPO60 Hand accelerometer adaptor T bar IADP061 Handle accelerometer adaptor straight bar IADPO62 Clamp accelerometer adaptor mounting block with clamp IADP063 Palm accelerometer adaptor NOTE Sensor and cable must be purchased separately IHVM100 L X GT Same as IHVM100 L X plus one each IHVM100 HA Hand Arm filter option IADP063 Palm accelerometer adaptor NOTE Sensor and cable must be purchased separately IHVM100 L X ALL Same as IHVM100 L X plus one each IHVM100 HA Hand Arm filter option IHVM100 WB Whole Body filter option IADPO60 Han
4. Industrial Hygiene Vibration Monitor Typical Applications J J C Worker Exposures Ergonomic Evaluation Workstation Design and Optimization Assess Risk of Injury Qualify Hand tool Performance Determine effectiveness of Anti Vibration gloves and materials Features 3 Frequency weightings and measurements for Hand Arm and Whole Body Vibration Conforms to ISO Standards 2631 and 5349 Simultaneous 3 channel Measurements X Y and Z axes plus Sum S Lightweight and Portable operates from two AA batteries or AC power supply Records up to 200 hours of measurement time history Programmable AC or DC Signal output Serial Interface to PC 115 2 kBaud Model IHVM 100 warsovoans HVM 100 Exposure of workers to high levels of vibration has been shown to cause permanent injury if left unchecked and untreated Determining the risk of exposure to excessive vibration levels that are routinely encountered when using machines in repetitive work activities should be considered as part of a comprehensive Ergonomic evaluation program Until now obtaining objective and repeatable vibration level data has been far more of a chore than is necessary The IHVM 100 from Larson Davis provides a practical means for quantifying exposure data on the job whether the work is performed inside manufacturing or process plants or at the most remote agricultural mining or logging sites Wherever there is work
5. clude one each ICBLO06 RS 232 Computer interface cable ICBL124 AC DC Output cable ICCS020 IHVM100 Hard shell carrying case PSA027 IHVM100 Power supply SWW _BLAZE Analysis software for IHVM100 Larson Davis A PCB Group Co NOTE 3 Input Channels for Single Axis Accelerometers or One Triaxial Accelerometer IHVM 100 Power Supply IPSA027 Cable Assemblies ICBL120 3 10 32 coaxial to 4 pin LEMO ICBL122 4 pin 1 4 28 thd to 4 pin LEMO ICBL125 4 pin mini to 4 pin LEMO System Details Printer Gln os g ICBL124 e AC DC Output gt gt ooon Cable IPCB 394C06 The 394B06 provides a controlled vibration level for verifying sensitivity of accelerometers of up to 85 grams in weight IPSA027 90 to 264V to 12V switching power supply for IHVM100 ISEN020 CBL Triaxial accelerometer 1 mV g ICP amp ICBL122 ISENO21 CBL Triaxial accelerometer 10 mV g ICP amp ICBL122 ISENO21F CBL Triaxial accelerometer 10 mV g ICP amp ICBL122 The ISENO21F has an internal filter which helps attenuate high frequency vibrations before they can overload the internal preamplifier in the accelerometer ISEN022 CBL Triaxial accelerometer 100 mV g ICP amp ICBL122 ISEN023 CBL Single axis accelerometer 1 mV g ICP amp ICBL120 _ISENO24 CBL Single axis accelerometer 10 mV g ICP amp ICBL120 _ISENO25 CBL Single axis accelerometer 100 mV g ICP amp ICBL120 _IS
6. d accelerometer adaptor T bar IADP061 Handle accelerometer adaptor straight bar IADP062 Clamp accelerometer adaptor mounting block with clamp IADP063 Palm accelerometer adaptor NOTE Sensor and cable must be purchased separately IHVM100 L X HAWB Same as IHVM100 L X plus one each IHVM100 HA Hand Arm filter option IHVM100 WB Whole Body filter option IADP060 Hand accelerometer adaptor T bar IADP061 Handle accelerometer adaptor straight bar IADP062 Clamp accelerometer adaptor mounting block with clamp NOTE Sensor and cable must be purchased separately IHVM100 L X WB Same as IHVM100 L X plus one each IHVM100 WB Whole Body filter option NOTE Cables and sensors available separately consult factory Larson Davis provides a complete line of acoustic measurement tools including dosimeters sound level meters real time analyzers preamps calibrators and microphones
7. eful and practicable for Safety and Industrial Hygiene professionals to implement This methodology uses a broadband measurement of only the frequencies of interest for determining the severity of the two main types of exposures This approach simplifies the number of readings that must be taken and coupled with the IHVM100 vastly increases the speed at and accuracy of which an assessment can be made BAD VIBES Hand Accelerometer Adaptor IADP060 Single Axis Accelerometers ISEN023 ISEN024 ISEN025 Handle Accelerometer Adaptor IADP061 Triaxial Accelerometers Clamp Accelerometer a ISENO20 Adaptor pz ISEN021 IADP062 ISEN021F ISEN022 Palm Accelerometer ISEN026 Adaptor IADP063 Triaxial Seat Pad Accelerometer with Cable ISEN027 CBL Hard shell Case ICCS020 IHVM100 ACC Hand held ICBLOO6 Accelerometer ICBL124 Calibrator IPSA027 1g RMS 159 2 Hz SWW_BLAZE IPCB 394C06 all in CCS020 Technical Specifications Input types ICP sensors charge output sensors direct voltage Input range gt 100 dB in multiple ranges Range gain x1 x10 x100 x1000 Calibration By level or sensor sensitivity entry Units m s cm s ft s in s g dB Metrics for each mode Vibration Arms Amin Amax Aeq Amp PEAK Hand arm Arms Amin Amax Aeq Amp PEAK A 1 A 2 A 4 A 8 A 8 AET Whole body Arms Amin Amax Aeq Amp Peak CFm
8. ort equipment or whose operator stations are in proximity to heavy rotating stamping or reciprocating machinery Physical effects to the worker can include damage to the spinal column and can manifest as low back pain or back neck and shoulder disorders Some studies point to possible negative reproductive effects in female populations exposed to high levels of Whole Body vibration Until now it has been difficult to quantify these exposures accurately and consistently Vibration must be measured in three directions or axes simultaneously and this acceleration information must be integrated into useful values and scientific units of measure Further measuring the frequency range of the vibration is critical to assessing the potential for physical damage For example the frequencies of interest in determining potential injury from hand tools are as high as 2500 Hz whereas Whole Body vibration exposures are most damaging at lower frequencies in the case of the spinal column primarily from about 0 2 to 8 Hz Shoulder Girdle Lung Volume Chest Wall 50 100 Hz Lower Arm 30 40 Hz Abdominal Mass 1 4 8 Hz aN gt 7 Seated Ferson ag Spinal Column axial mode 10 12 Hz Legs variable from ca AF 2 Hz with knees b flexing to over ZO Hz with rigid posiure Standing verson OD Wh ol e Body Recent ISO standards have been promulgated that define measurement criteria and exposure limits that are us
9. p CF VDV Frequency weightings Vibration Ws Severity Fa 0 4 Hz to 100 Hz Fb 0 4 Hz to 1250 Hz Fe 6 3 Hz to 1250 Hz Hand arm Wh Whole body Wb Wc Wd We Wg Wj Wk WB Setups Store up to 10 user setups Memory 100 measurements 1 min to 99 hr Time history 120 samples of Arms and PEAK at a period of 1 2 5 10 20 30 60 seconds Interface RS 232 on 8 pin DIN up to 115 kbps Printout Custom 3 line header data and time history Outputs for each channel AC Weighted or band limited DC rms min max peak sum rms sum max sum min sum peak Peak 0 5 dB accuracy Power 2 AA batteries IEC Type LR6 batteries included Weight 300 gm 10 6 oz Dimensions 1 1 x 3 3 x 6 0 in 28 x 84 x 152 mm Standards met ISO 8041 1990 Amd 1 1999 2631 1 1997 2631 2 1989 2631 4 2001 5349 1 2001 and 9349 2 2001 plus it provides the Whole Body frequency weighting Wg specified in the British Standard BS 6841 1987 CE compliant User manual included Accessories optional _IADPO60 Hand accelerometer adaptor T bar o o _1ADPO61 Handle accelerometer adaptor straight bar _ _1ADP062 Clamp accelerometer adaptor mounting block with clamp _IADP063 Palm accelerometer adaptor SSS _IADPO64 __IHVM100 adaptor kit includes hand handle clamp and palm adaptors ICB L006 Serial interface cable for IHVM100 Used to connect to a PC ICCS020 IHVM100 Hard shell carrying case IHVM100 ACC Accessories in
10. ry Two common types of vibration exposure have been identified as deleterious Hand Arm vibration and Whole Body vibration These exposures are prevalent in the following applications e Construction e Foundries Metalworking e Transportation Material Handling e Logging e Shipbuilding e General Industrial Hygiene Head axial mode intraocular 20 30 Hz structures Hand Grip 50 200 Hz Hand Arm Worker exposure to high levels of vibration from powered hand tools can cause vibration syndrome symptoms such as numbness pain tingling and blanching Vibration syndrome exposures induce adverse circulatory and neural effects in the fingers and hands that can become irreversible if left unchecked over as little as one year s time Reduced tactile feeling and dexterity resulting from these exposures decreases workers ability to perform critical tasks with precision Often called vibration white finger disease VWF this condition is progressive and debilitating Pneumatic and electric powered hand tools are often the cause of these unacceptable exposure levels and even hand tools that were initially selected to emit lower levels of vibration may degrade through typical use and lack of or improper maintenance leading to increasing and ultimately unacceptable levels over the working life of the tool High levels of Whole Body vibration exposure are common to workers who operate heavy machinery material handling and transp
11. to be done using heavy equipment or rotating or reciprocating hand tools powered by air electricity or internal combustion the IHVM 100 is the easy way to obtain and document the levels of exposure that have been proven to cause a wide range of potential injury including Vibration White Finger Disease VWF and other more insidious physical effects IHVM 100 Simplifies Vibration Exposure Monitoring The IHVM 100 is a hand held instrument for measuring human exposure to vibration performing relevant calculations and providing overall metrics on its LCD display Detailed vibration levels are easily stored in its built in data logger which can hold up to 100 separate time history test files including all required metrics This information can then be downloaded to a PC for analysis and archiving Measuring all three axes of vibration simultaneously greatly simplifies the setup of a test and enhances the repeatability and correlation of the vibration data From the three channels of measured data the IHVM 100 automatically calculates the important vector sum information and presents it as a fourth set of data values For compliance with the latest measurement standards the IHVM 100 employs digital filters for each channel that can be enabled as needed and will never be obsolete should standards change the filters can upgraded electronically j mpi id Amplitude Amplitude f Input Force h oystem Kesponse Vibration

Download Pdf Manuals

image

Related Search

Related Contents

LABORATOIRE PUBLIC D`ESSAIS ET D`ÉTUDES  Instrucciones de servicio EOT  CD Booklet_Oriya Ver4  GEBRUIKSAANWIJZING MODE D`EMPLOI  Manual de servicio SelfCooking Center®  チタニウムミッドYパイプ  CaddX Server  STREETSMART PRO® REFERENCE  Integración de EFI Digital StoreFront con Fiery Envío directo de  Powerplus POW30540 rotary hammer  