Essentials of Motion Capture v1.2
Contents
1. CONTENTS V CON MOTION SYSTEMS Using the pipeline 41 The processing log 44 CLEANING UP DATA Types of problem in 3D data 46 Diagnosing the cause of problems 47 Viewing trajectories 49 Editing 3D Data 50 Using BodyBuilder for data editing 58 INDEX 59 Revision history NAVIGATION PUBLICATION E2 E ESSENTIALS OF MOTION CAPTURE THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Setting up the Eclipse database Workflow This chapter takes you through all the basic steps required for motion capture once you have prepared the system The later parts of this section provide more detail about these individual steps The workflow described here is e Set up the Eclipse hierarchy to organise you motion capture data e Check the system is working correctly e Calibrate the system e Capture a static trial e View the captured data e Label subject and create a Subject Calibration e Capture a dynamic trial e Reconstruct and label the data e Clean up and edit data Before performing motion capture you should have e Software installed hardware connected and the system functioning correctly e Capture Space set up e A subject with markers attached Datastation and Workstation have both been started and Link established Motion Capture Before starting you should decide where you wish to store your Vicon data You then implement this using the Eclipse data managemen
2. Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE VIEWING DATA VICON MOTION SYSTEMS Opening a Trial Navigation The Workstation Time Bar Replaying the Trial Workstation offers many different ways of visualising and interacting with captured data The most frequently used tools are the 3D Workspace window and the Time Bar You can open trial data windows directly from the Data Directory window by double clicking the appropriate icons for Movie for Analog for 2D Video Monitor for 3D Workspace or the trial name for the default view either 3D Workspace or 3D Workspace plus Movie You can also access these windows as well as the Continuity Chart from the Windows menu Navigate around the 3D Workspace using the mouse e Drag the mouse with the left button down to rotate the viewpoint at a fixed distance about the centre The rotation centre is marked with a purple diamond in the window If you do not see the purple diamond select View Rotation Center e Drag the mouse vertically with the right button down to zoom in and out of the space e Click and drag with both buttons pressed or Control plus the left button pressed to move the centre of the view Using the Time Bar to control playback D M vomon M ef e laoa e a E mel To view the motion click Play m in the Time Bar at the bottom of the Workstation window your captured sequence will automatically loop
3. PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS Crossovers The purple rotation centre will appear at the centre of the trajectory allowing you to zoom in and move around If you have already defragmented your trajec tories then the rotation centre may appear at the origin of the Workspace This means that the centre of the trajectory is actually a gap In this case use the Step Forward or Step Back buttons in the Time Bar until you see the yellow labelled trajectory You may also find it useful to use the triangular sliders to extend the range of the visible trajectory You can also use the Continuity Chart to view unlabelled trajectories Here all trajectories are laid out in order and you do not have to struggle through the mass of other trajectories Ghosts and phantoms will be apparent due to their short lifetimes You can find and select trajectories in the same way you do in the 3D Workspace That is as you click on the trajectories they will change colour as the do in the 3D Workspace Also you can switch between the two views and the selections of the trajectories will remain If there are many crossovers check that markers are correctly located on the subject You should also check the reconstruction parameters in particular the Intersection Limit and the Predictor Radius Reconstruction Parameters are discussed in The Essentials of Motion Capture You should also check the calibrat
4. Note that it will not loop back to the start when you finish Drag slider to change speed Right for forward play Left for reverse play Shuttle button in Shuttle position Click on any frame in the Time Bar to jump to that specific frame or drag the large empty square slider to scroll through the trial You can also step through the trial frame by frame using Step Forward and Step Backward 4 Click Previous Next m mi to jump to the start or end of the trial If events have been defined this will take you to the previous next event instead see the Gait Analysis scenario In some trials the subject may move into the capture volume after the trial has already begun and move out of the volume before the trial has ended This is a good practice if the subject needs to get up to speed or you are trying to maximize the amount of data captured for a particular activity such as the NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE VIEWING DATA VICON MOTION SYSTEMS View only the interesting frames Using the Time Bar Ruler to display the trial Marking Events number of gait cycles in a walking trial In such cases there may be time at the beginning and end of the trials that has no or meaningless data in it The Time Bar allows you to trim any unwanted frames The two triangular Save Range Sliders at the top of the ruler allow
5. e Click New in the Define Subjects dialog e Enter the unique subject name when prompted and click OK e Click Close Now when you open the Create Autolabel Calibration dialog you can select the new subject from the Subject name list The User Preferences dialog includes a setting to create a default subject when you create a new session e Select File User Preferences e Select or Clear Create a Default Subject If you select the option then a new subject will be created for each session This will be displayed in the Subject Name lists in Capture Trial and Create Autolabel Calibration dialogs as Subject You can still create a new the subject at the time that you create the autolabel calibration simply by specifying a new name in the Subject Name field NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE AUTOLABELLING VICON MOTION SYSTEMS Check the green stick figure Find Unlabelled Trajectories Using the Mouse Helper Checking the Autolabel results To check the autolabel results you can play the trial and look for several tell tale signs Check the shape and attachments of the green stick figure As you get more comfortable working with a particular marker set you will find that you can tell a lot about the quality of the autolabel results by watching it move through your capture volume If the shape does not look right then some labels have been applied to the
6. also found in the Edit menu is used to fill large gaps by copying the points from a similar trajectory To decide which trajectory to copy from view the trajectories on the same body segment as the broken trajectory e Select each trajectory in turn e Select Workspace Show Trajectories A visual inspection will indicate which trajectory most closely follows that of the broken trajectory When you decide which one to use e Select the ends of the gap in the trajectory you wish to copy to You can do this by extending the trajectory paths as described above under Viewing trajectories Once the path of the trajectory with the gap is extended to the point that you can see data on both sides of the gap then you can click on both ends of the gap Hold the Ctrl key down while you select the second point If you have done this correctly you should see a white cross at end of the gap in the selected trajectory A more efficient way to do this is to use the Find Next Gap command on the Workspace menu e Click anywhere on the trajectory you wish to copy from e Select Edit Copy Pattern After performing a Copy Pattern you should look closely at the three dimensional movement to ensure that it is correct If it is clearly wrong you can use the undo feature You may occasionally come across odd points or sections of trajectories that are clearly at odds with the main flow spurious points and overlaps These often occur near the start and
7. Label Fill Gaps Cei Apply Woltring filtering routine Process Now Save Trial Save Subjects Separately Export data to ASCII file Create CSM File s Distance Statistics Collection Process Options OCapture Next Trial Rt Subject Calibrator Kinematic Fitter Using the pipeline The pipeline is a very simple dialog comprising a list of available features To set a pipeline option e Open the Pipeline dialog either from the Trial menu the Trial Types dialog or the Trial Data capture dialog e Click the selection box next to the function you wish to run e When selected a tick check mark appears in this box Click again to clear the selection and turn off remove the pipeline function If appropriate as seen in the figure above you can make multiple selections If you have a trial open then you can click Process now to run the Pipeline on that trial Some functions have a series of options available For example for Reconstruction you can set the reconstruction parameters to be used To set the options e Click the text of the required function e Click Options The appropriate Options dialog opens Set the parameters and close the dialog to return to the pipeline When you click the name of the function it will be highlighted but not selected as a pipeline function If you click the selection box to the left it will be selected as a pipeline option and highlighted at the same time One very useful Pipeline opt
8. TRIAL TYPES V CON MOTION SYSTEMS e Using Sample Skip to alter the capture rate e Adding pipeline options for example to always reconstruct and label the subject analyse save and export NAVIGATION PUBLICATION ESSENTIALS OF MOTION CAPTURE THE VICON PIPELINE VICON MOTION SYSTEMS The Pipeline offers a method of automating you motion capture and data processing The pipeline can be used in three different situations e Immediately after capture in conjunction with a trial type e Onan open trial e On a group of selected trials The pipeline allows you to set a number of processing options such as reconstruction and labelling These options may be included in a trial type so that they are run every time the type is used Alternatively you can open the pipeline dialog for any trial set the options and run them directly If you have captured a lot of data in several trials and want to process these later you can select these trials in Eclipse and run the pipeline as a batch process A number of pipeline options are available with every system You may also have purchased any of a number of Vicon plug ins or have created your own plug ins These are specific data processing modules such as Plug in Modeller and Plug in Gait When these are installed with your Vicon system they will appear in the Pipeline dialog and are run as pipeline processes Default pipeline capture and reconstruct d
9. To stop the playback click Stop To the right of the Play button a series of buttons allow you to step through the trial frame by frame or to jump to the start and end The slider to the left is normally used to control the speed of playback Dragging to the right increases speed forwards Dragging to the left increases speed in reverse NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE VIEWING DATA VICON MOTION SYSTEMS Save only the Range of Playback slider in Normal mode Playback in shuttle mode Displaying Specific Frames Interesting Frames Drag slider to change speed ae button right for forward play in Normal left for reverse play position If View Real time Playback is switched on you can set your playback rate by adjusting the slider to any rate up to 4 0 double clicking on the slider restores the standard rate 1 0 Alternatively if View Real time Playback is switched on and you can select Shuttle Mode e Click the Shuttle button 4p To the left of the main Play button You will notice the background colour of the slider changes In Shuttle Mode the position of the slider controls the speed of playback though a single pass of the trial e Move the shuttle slider to the left to play at rate indicated to the start of the trial e Move the slider to the right to play at the indicated rate to the end of the trial
10. Trial Trial Types to open the Trial Types dialog e Select the type you wish to delete from the Trial Types drop down list e Click Delete You will be prompted to confirm that you do indeed wish to delete the type On clicking yes the drop down list will be refreshed Finally click OK to close the dialog This section serves to reiterate some of the uses of the trial types feature Trial types are used to store settings for specific capture protocols These can then that can be used with a couple of clicks of the mouse instead of resetting every parameter every time Note that trial types are greatly enhanced by the use of the Vicon Pipeline This stores data processing options More about the Pipeline is discussed in the next chapter In each of the following examples the capture and processing options could be selected on a trial by trial basis but the trial types feature allows these settings to be selected consistently quickly and easily for many trials e Subject Calibration or static trial capturing video data for three seconds only e Trials involving capture of specific combinations of data video movie or analogue e Timed Capture for predictable situations such as the static capture e Using Post Triggering for unpredictable trials such as children or animals e Including a specific marker set for a number of trials NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE
11. Vicon folder e Click OK A list of marker names will appear in the Labelling Control Bar at the right of the Workstation window You could have specified a default marker set in the Trial Types dialog above in which case this marker set would already have been attached when you captured your data To attach a default marker set to the Static Trial type e Select Trial Trial Types e Select Static Trial in the Trial Types drop down list e Under Default Marker Set click Browse and locate the marker set e g HumanRTkm mkr e Click OK The next time you perform a Static Trial capture this marker set will be automat NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Label a marker Create the Subject Calibration Check the Subject Calibration ically attached to the subject e Adjust the workspace until you have a clear view of at least one marker you recognise e Move the mouse over the marker A small window will appear showing the label for that marker currently dashes since the marker has not been labelled e Click to select the marker It should turn yellow if you accidentally select the wrong one click the right mouse button to deselect and then try again Click on the corresponding label in the Labels List in the Labelling Control Bar The marker should turn light blue and a number one should appear next
12. as short timed trials where you do not want to go through the complete process of specifying capture parameters For efficient off line processing of multiple pipeline options on a single trial For off line processing of multiple trials including e Reconstruction and labelling e Modelling for gait analysis or kinematic fitting e Export of files to ASCII and CSM NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS Broken trajectories Phantom markers Ghost trajectories Unlabelled trajectories Blooming flickering and merging Ideally each marker on your subject will be reconstructed to produce a smooth trajectory throughout the trial Unfortunately there will frequently be frames where some markers cannot be reconstructed leading to breaks in trajectories There may also be some spurious data phantom markers and ghost trajectories and odd spikes points in trajectories that clearly do not lie on the general curve This chapter describes the nature and sources of typical problems and how to edit your data to correct them Types of problem in 3D data Broken trajectories are the most common problem They arise from markers being hidden from sufficient camera views such that Workstation cannot reconstruct the trajectory at that point This is known as occlusion and can occur for example when a body segment subject or prop obscures the
13. cameras contributing to the re construction in each frame This is easy to use as all trajectories are parallel lines and it is easy to scan through to locate breaks Locate the break and check which cameras were contributing to the trajectory just before the gap occurs NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS The subject walks out of the volume Loss of calibration Unlabelled markers The most certain way to determine whether reconstruction parameters or lack of complete 2D video data is to blame for poor 3D data is to check the video data in the Video Monitor window for the period of time in which there is a break Remember there must be video data for a given marker in at least two camera views in order for the system to be able to reconstruct any 3D data If it is determined that the poor 3D data is the result of improper Reconstruction Parameters the best way to start cleaning up the data is to go back change the Reconstruction Parameters and then re reconstruct the 3D data The loss of calibration in one or two cameras is most obviously seen as an increase in the number ghost trajectories To be sure of these open a new continuity chart and locate the ghosts You will notice that the same cameras are contributing to these trajectories The best solution is to open a new session and recalibrate If the subject is
14. ghost 46 label manually 51 overlapping 52 unlabelled 30 viewing 49 Trial replay 21 run pipeline on 43 Trial Type 34 dialog 34 for dynamic trial 06 for static trial 06 Trouble shooting reconstruction problems 25 U Unlabelled Trajectories finding 31 Unlabelling trajectories 27 V View menu 24 multiple labelled trajectories 49 part of a trial 23 trajectories 47 E2 ESSENTIALS OF MOTION CAPTURE
15. marker An example would be when a subject bends over at the waist If all your cameras are mounted above head height then the chest markers might be occluded by the subject s own body If you have more cameras and optimise their position for a given task then this is less likely to cause a problem Phantom markers are recognised as single markers some distance from the main subject often near the edge of the capture volume and only visible fleetingly during playback These appear rarely when rays from two coplanar cameras intersect each other at more than two locations The result is multiple reconstruction points manifesting as extra markers A ghost trajectory can be recognised as an additional trajectory very close to an existing one appearing over a short duration The real and the ghost trajectory are usually separated by a value similar to the Intersection Limit set in the Reconstruction Parameters dialog This parameter is related to the calibration results and either may be the cause Unlabelled markers may be phantom markers ghost trajectories or trajectories that the autolabeller has missed How many of these you have are indicated in the Unlabelled pane of the Labelling Control Bar when the 3D Workspace is open for a given trial This displays the number of unlabelled trajectories in the current frame and in the whole trial Blooming flickering and merging are all manifestations of poor video data This may be a consequence o
16. of trials that need to be processed It is usually a good idea to process one or two of the trials manually in a step by step fashion so you can check the quality of your data and verify what the appropriate settings are Having done this you can batch process all of the trials through the same pipeline e Open the Eclipse Data directory window by pressing F2 e Locate several trials in a calibrated session which are ready for reconstruction and autolabelling e Right click each of the required trials and select Batch Process from the short cut menu e Select Pipeline from the Trial menu in the main Workstation window e Select Reconstruct and Label from the list of pipeline processes choosing appropriate options e Click Process Now The data processing log opens and details the progress of the pipeline see below This is useful if things go wrong during the pipeline process When complete you will be asked whether you wish to save the changes the trials individually There is also a pipeline option for saving the trial If you choose this option the processed trials are saved automatically You can select as many trials as you wish to batch process so it is quite possible to spend a day in the studio capturing data and then leave your system to process the data over night We recommend checking the quality of each individual trial after batch processing NAVIGATION lt PUBLICATION ESSENTI
17. or General to apply an event at the currently selected frame e Click Clear Events to remove all events from the current trial NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE VIEWING DATA VICON MOTION SYSTEMS Icons for labelling events in trial Select to place left side 2 Place Foot Off event m event gt Select to place right side Place Foot Strike R event e Event Select to place general e event l Place General Event Clear all events a Note that Plug in Gait available with the Science and Engineering version of Workstation can automatically detect some events These buttons are used manually adding events to a trial General viewing options the View menu The View menu provides a number of options for enhancing the view in the 3D Workspace All are toggle switches i e selecting them on the menu switches them on if they are off and off if they are on On is indicated by a check mark Reconstruction Volume displays a rectangle defining the reconstruction volume described above in Reconstructing 3D Data Force Plates displays the position of force plates if their locations have been specified in the Force Plates Setup dialog see Capturing Analogue Data Floor and Furniture displays the 2D grid representing the floor and if configured furniture Objects such as furniture can be specified in the 3D workspa
18. save the file for your records then the file may be renamed in the normal manner using the Windows utilities Whether or not you wish to view the log file is a matter of user preferences e Select User preferences from the File menu In the bottom right of the User Preferences dialog a small panel labelled Open Processing Log Window This offers any or all of the three selections After Capture Running pipeline on an open trial Running pipeline on selected trials NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE THE VICON PIPELINE VICON MOTION SYSTEMS Some common uses of the pipeline The default setting has the window displayed only when the batch processing option is being used You can also view the Processing Log at any time by go to View Processing Log on the menu The following merely provides a reiteration of some of the common uses of the pipeline As part of a trial type to provide specific processing options immediately after capture In the example trial types e Subject Calibration includes reconstruction in the pipeline e Pipeline Capture includes reconstruction and labelling e Repeated Capture includes Capture Next Trial Create your own pipelines as part of a trial type for example e To process atrial for gait analysis using the Plug in Gait options if available e To automatically save trials when they are captured e For repetitive work such
19. trajectory LFIN e Select the second trajectory LFIN at a position just before the crossover starts NAVIGATION PUBLICATION gt ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS e Hold down the Control key and select the same trajectory just after the crossover e Select Edit Snip Trajectory LTHI This removes all points between the two selected Repeat this for the trajectory LFIN e Select the second trajectory LFIN at a position just before the crossover starts e Hold down the Control key and select the same trajectory just after the crossover e Select Edit Snip Trajectory LTHI The crossover section of this trajectory is also removed The next steps are relabelling defragmentation and filling the gaps e Click Select in the Mode panel of the labelling control bar e Select the segment of LTHI after the break e Click Unlabel e Select the segment of LFIN after the break e Click Unlabel These unlabelled segments should be displayed white as compared to the blue for labelled trajectories e Click Label in the Mode panel of the Labelling Control Bar e Select the unlabelled segment that was incorrectly labelled LFIN e Label it LTHI e Select the unlabelled segment that was incorrectly labelled LTHI e Label it LFIN Now defragment to ensure that Workstation recognises all identically labelled segments as belonging to the same trajectory e Select E
20. wrong trajectories or some trajectories have not labelled at all Asa side note you should make a practice of building asymmetry into your marker sets This asymmetry will help you determine quickly by looking at the green stick figure whether or not the autolabel calibration has produced good results You should also look for any white unlabelled trajectories An easy way to locate any trajectory that may have escaped auto labelling is to e Select Workspace Next Unlabelled Trajectory The next unlabelled trajectory will be displayed and selected If you recognise this you can label it manually as above and repeat until all trajectories are all labelled Note the menu option will be greyed out if there are no unlabelled trajectories in your trial For a visual inspection you can hover the mouse pointer over a labelled marker The Mouse Helper pop up window displays the label assigned to that marker Check each marker to verify that it has the correct label To use this feature ensure that Mouse Helper is selected in the View menu Reasons for poor autolabelling Autolabelling can result in three likely outcomes e All the trajectories are labelled correctly e None of the trajectories have been labelled e Some trajectories remain unlabelled or are labelled incorrectly The first is obviously the most desirable outcome but if this is not the case there are a number of possible reasons for a less than perfect result If no trajecto
21. you to define which frames you want to save for subsequent use The regions to discard are indicated by the purple region on the Time Bar This is the same as selecting Trial Trajectory Save Range and then setting the frame numbers manually Double click on a range slider to toggle the range between the first or last frames and the last user defined frame If you want to only view a portion of the trial and have the particular section keep looping you can drag the Play Range Sliders 9 to set the range for viewing If you then click Play m only the portion of the data in that time range will be displayed It can be useful when editing to replay a small section of the trial to make sure your edits are done correctly More accurate positioning of sliders can be achieved by zooming in on the Time Bar Click and drag with right mouse button on the Time Bar ruler to zoom the scale Drag to set Drag to scroll Click to the save range through trial jump to for the trial y frame Drag to set Drag to set visible limit of playback limits of trajectories Marking events is mostly used when studying clinical or sports motion for example in Gait Analysis Events are displayed as icons in the Time bar Canvas beneath the Time Bar Ruler The Canvas comprises three parallel lines to display Left side Right side and General events respectively e Select the Left Right or General to activate display of an event e Click Foot Strike Foot Off
22. ALS OF MOTION CAPTURE THE VICON PIPELINE VICON MOTION SYSTEMS To save time when selecting trials for batch processing you can select a whole session e Right click a session that is ready for processing and select Batch Process from the shortcut menu This should select every trial within that session and display a red tick by each one Now when you run the pipeline every trial will be processed in turn The log will display when each trial is opened for processing The processing log The processing log is a text file log txt usually stored in the System sub folder of the main Vicon installation folder The file is displayed by default when you use the pipeline to process a number of trials for batch processing in the Eclipse Data Directory window During the pipeline process you can click e Pause and Resume to temporarily halt and restart the pipeline e Stop to terminate at a specific point e Cancel to stop the process without saving any changes When the pipeline has finished e Close to close the log file window e Clear to empty the contents of the log file e Browse to locate the log txt file if it has been saved to a different location Notice that the log file appends any new information to the bottom of the current log file so you will have to scroll to the bottom each time to see the latest information It may be useful to clear the contents from time to time You will be asked to confirm this action If you wish to
23. AVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE RECONSTRUCTING 3D DATA V CON MOTION SYSTEMS Have you got the best What are the causes of results a high segment count Swapping Improper reconstruction Either of these can cause misidentification parameters of trajectories at a certain frame The OR autolabeller then mislabels and the effect Markers too close to each is that the trajectories cross over or swap other paths at that frame If you come to the conclusion that the reconstruction is unsatisfactory then you can simply run the reconstruction again e Select Trial Reconstruction Parameters e Make changes according to Optimising Reconstruction Parameters below then click OK e Select Trial Reconstruct The trial is reconstructed again from the raw video data and overwrites the previous reconstruction A message will appear indicating this e Click OK The quality of the reconstruction There are several ways to check the quality of your 3D reconstructions The first is to watch the left side of the status bar during the reconstruction process This tracks the number of frames also called fields reconstructed When complete it will state the number of segments created If all trajectories are unbroken then there should be one segment per marker If some trajectories are broken then there will be more segments than markers This of course gi
24. Fill Gaps In name of selected trajectory Fill gaps in a selected range e Select a trajectory e Click to select the first point in the range e Holding down the Control key press the last point at the range The two ends of the range are highlighted with crosses e Select Edit Fill Gaps In label of trajectory Filling all gaps in all trajectories e Select Edit Fill All Gaps Only gaps below the maximum fill size will be filled Define the maximum size of gaps to be filled Define the maximum size of gaps to be filled The cubic spline interpolation used to fill gaps can give unrealistic results if used on large gaps You should therefore set a maximum gap size for the Fill Gaps method NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS Copy Pattern large gap fixing Specific points e Select Edit Maximum Fill Gap e Set the maximum size as an integer in the Restricted to Samples field You can alternatively select No Restriction to allow this method to be used for all gaps This should only be used if you know that all the gaps are fairly small A better method for fixing large gaps is the Copy Pattern method see below After performing a Fill Gap command look closely at the three dimensional movement to check that the result looks realistic If not you can use the edit menu to undo the fill The Copy Pattern command
25. Select Default or last used subjects Subject Video None Time 3s Static Trial Calibration Include subject names in labels Timed Video None Time 1s Include subject names in Capture labels Select Default or last used subjects Video and Video None Time 5s Include subject names in Analogue Analog labels Select Default or last used subjects Video and Video Video monitor Indefinite Include subject names in Movie Movie Movie data labels Select Default or last Capture used subjects You can use any of these trial types or use them as a starting point to create for your own To modify them you might rename them or simply change the settings To rename a Trial Type e Open the Select Trial Trial Types to open the dialog e Select the type you wish to rename from the Trail Type drop down list e Click Rename NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE TRIAL TYPES VICON MOTION SYSTEMS Edit a Trial Type Delete a Trial Type Some common uses of the Trial Types feature e Type the new name in the pop up dialog and click OK e Click OK to close the Trial Types dialog To change any of the settings for a trial type e Select Trial Trial Types to open the Trial Types dialog e Select the type you wish to edit from the drop down list e Change any settings as appropriate e Click OK To delete a Trial Type e Select
26. To look at the setting for this trial type e Select Trial Trial Types e Select General Capture in the Trial Type dropdown list If you do not see this trial type in the list then you will have to create it To create a new trial type e Click New e Enter the Trial Type name General Capture e Click OK You have now created the type The next step is to enter the settings that will be stored under this name The Trial Types dialog is divided into a number of panels To create the General Capture trial type set options as directed below The name of the type is displayed in a drop down list at the top of the dialog This is the name added in the Enter Trial Type name dialog To select a different NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE TRIAL TYPES VICON MOTION SYSTEMS Capture Open Windows Default Duration Default Marker Set Sample Skip Post Triggering trial type just select it from the drop down list The Capture panel shows three options and allows you to select what type of data you wish to capture You can choose any combination of Video Analogue or Movie data though you must choose at least one Click to select or clear each option For General Capture you are only interested in video data not movie or analogue so select Video Data and clear Movie and Analogue options Open Windows allows you to select which windows will open a
27. VICON MOTION SYSTEMS NAVIGATION PUBLICATION 2 ESSENTIALS OF MOTION CAPTURE CONTENTS V CON MOTION SYSTEMS This section describes the common workflow of a motion capture session Whether you are performing routine motion capture or using advanced techniques you will need to perform the tasks outlined in The Motion Capture Session More complex motion capture techniques are described in Advanced Capture Techniques This section assumes that you have performed all of the tasks described in Preparation The following chapters describe the individual steps in detail Finally Clean Up describes methods of solving problems with your data THE MOTION CAPTURE SESSION Workflow 04 Motion Capture 04 CHECKING THE QUALITY OF THE VIDEO DATA 15 RECONSTRUCTING 3D DATA Reconstruction Parameters 16 The quality of the reconstruction 17 Optimising Reconstruction Parameters 18 VIEWING DATA Using the Time Bar to control playback 21 General viewing options the View menu 24 Other Windows 25 LABELLING THE DATA How to assign a label 27 AUTOLABELLING Autolabel calibration 29 Checking the Autolabel results 31 Reasons for poor autolabelling 31 Autolabel parameters 32 TRIAL TYPES Default trial types General Capture 34 Default Trial Types More examples 37 THE VICON PIPELINE Default pipeline capture and reconstruct data 40 NAVIGATION PUBLICATION gt ESSENTIALS OF MOTION CAPTURE
28. ata The pipeline trial type A number of useful default trial types that include pipeline options are included with the Vicon installation In the example earlier in this chapter you might have looked at some of the settings for the Pipeline capture trial type If you used the Pipeline trial type immediately after you stopping capture you would be able to observe Workstation going through the motions of reconstructing the data and autolabelling look at the status bar When complete the 3D Workspace window should open and the green stick figure should appear in the 3D Workspace window Take a look at the Pipeline dialog below to see what was done here This may be opened directly from the Trial menu or by using the Pipeline button in the Trial Data Capture and the Trial Types dialogs The dialog displays the list of pipeline options available in your version of Workstation You may have more or fewer options in your pipeline depending on the software packages you purchased and any plugs ins you have created or acquired In this example pipeline the Reconstruct and Label options have been selected Each selected option is processed in logical order NAVIGATION PUBLICATION I ESSENTIALS OF MOTION CAPTURE THE VICON PIPELINE VICON MOTION SYSTEMS The Pipeline dialog The list of functions depends on your version of Workstation Basic functionality Repeating captures i 2x MReconstruct
29. bel and possibly the subject s name You can unlabel individual trajectories using the Labelling Control Bar at the right of the main Workstation window e Select the trajectory you wish to Unlabel by clicking the light blue circle in the Workstation window e Inthe Control Bar click Unlabel NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE LABELLING THE DATA VICON MOTION SYSTEMS Label multiple trajectories Related topics If you notice half way through labelling that you are using the wrong marker set it is tempting to load the correct marker set and continue This can however lead to markers disappearing altogether if they are different in the two sets You should therefore unlabel all trajectories before changing marker sets You can at any time unlabel all the trajectories e Select Edit Unlabel All Trajectories Labelling trajectories one by one can be tedious especially when you come to recognise the markers and their names easily To speed things up Workstation will allow the user to select multiple markers remembering the order in which you selected them To label multiple trajectories e Adjust the 3D Workspace until you have a clear view of several unlabelled trajectories you recognise e Select a number of trajectories remembering the order in which you select them Note the colours as you select them the first yellow then red pu
30. cally defragmented Crossovers may be found by visual inspection Perhaps the first clue will be that during playback the green stick figure will change unexpectedly Where the crossover occurs the link between markers will change as the labelling changes between the trajectories You may inadvertently cause a cross over if you do not verify the labelling of trajectory fragments before you defragment To locate the NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS crossover accurately e Select the two trajectories suspected of crossing over e Select Workspace Hide Other Trajectories e Adjust the visible trajectory range using the two small sliders attached to the main slider on the Time Bar e Play back the trial in slow motion or step through a frame at a time The crossover will appear as a definite exchange between two trajectories where you would expect them to carry on smoothly If you wish to create a false crossover just to see what one looks like e Select two trajectories preferably two that are naturally close together e Select Workstation Show Trajectories to display only these e Adjust the visible trajectory range using the Time Bar e Zoom in on the trajectories to improve your view e Click to select a distinct position on the second trajectory selected e Select Edit Exchange Points The result is that the selected po
31. ce by modifying the file default wks found in the Vicon Wkspace folder The X Y Z coordinate axes object although not furniture is an example of an object defined in this file Camera Positions displays circles representing the camera positions as calculated by the calibration Camera Rays displays lines representing the cameras that contributed to the reconstruction of a selected marker NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE VIEWING DATA VICON MOTION SYSTEMS Video Monitor Continuity Chart e Click to select a marker e Select View Camera Rays e Click with the right mouse button to deselect the marker This can be useful when assessing the reconstruction as rays disappear when they do not contribute to a marker reconstruction For example if one camera consistently does not contribute then there may be a problem with the camera or its calibration Flicker Free When Workstation is run on older computer systems and some graphics cards flicker mode will allow the data to playback faster but is harder on the eyes Flicker Free is smoother but can be slow in playing captured data on these older computer systems Always Refresh Always Refresh is of more relevance to older computer systems The playback with this setting Off will be faster and smoother but the background and furniture will be overwritten by the movement of the subject With the se
32. ct you will need to create the Autolabel Calibration in the current session e Move to a frame in the current trial where all the markers are present and labelled e Select Trial Create Autolabel Calibration e Look in the Subject Name drop down list for the name of your subject e f you find your subject then select the name if not type the name in the Subject Name field e Under Field Range select Fields around current field and specify O e Click OK You have now saved the marker patterns for the current locations of the markers on your subject These are stored in the subject file lt subject name gt sp This autolabel calibration is only good for the current marker locations on this subject Should markers fall off or be moved you will probably have to create a new Autolabel calibration Finally as a precaution e Select File Save to save the trial including the manual labelling It is possible to calibrate a subject from any trial simply stop the trial playback in a neutral pose with all markers present and labelled and perform the actions described above It is found that better autolabel calibration is obtained if you set the field range to O even for static trials This is especially important if using a dynamic trial but also works for a static trial To create an autolabel calibration from a dynamic trial e Stop the trial playback in a neutral pose with all markers present and labelled e Repeat the steps given above
33. cting Mistakes Reconstructed data consists of three dimensional trajectories that represent the markers placed on the subject At this stage the software does not have a way to distinguish one trajectory from another The process of labelling allows the software to make this distinction This is necessary for future processing modelling visualisation and analysis The labels and the connections between them are stored in a text file called a marker set Labelling is the process by which labels are assigned to specific trajectories There are two main methods of labelling your subject manual labelling and autolabelling using the Autolabel function in Workstation How to assign a label Although you can manually label any trial it is common practice to use a static trial This makes it easier to recognise individual markers and have them all visible in a given frame The basic labelling technique is e In the Mode pane at the bottom of the Labelling Control Bar ensure that Label is selected e Select a trajectory in the 3D Workspace by clicking on the white circle that represents it When you click it should turn yellow e Click the label name in the Labels List of the Labelling Control Bar Mode Label C Select Unlabel When a trajectory is labelled it becomes a light blue colour in the 3D Workspace If you hover the mouse pointer over a labelled trajectory a window will pop up with the name of the assigned la
34. data e Select View Diagnostic mode again to return to the normal view You should use the diagnostic mode of the live monitor at the beginning of a data capture session to ensure that you are getting good quality video data This tool can also be used with the Video Monitor to help solve problems with poor quality three dimensional reconstructions For example if you have captured a trial with ten markers and only reconstruct eight then you can determine whether the cause of the missing data is due to lack of video data Alternatives would be improper reconstruction parameters or poor calibration NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE RECONSTRUCTING 3D DATA V CON MOTION SYSTEMS Possible outcomes of reconstruction The Vicon hardware captures two dimensional video data of marker reflections in each camera The Workstation software then takes this information and combines it with calibration data and a set of reconstruction parameters to create three dimensional positions for each marker in the Capture Volume The positions are calculated frame by frame and combined to create a complete set of trajectories of the markers positions throughout the time span of the trial Reconstruction Parameters Ideally the reconstruction should result in smooth and continuous trajectories the path of each marker for the duration of the trial through the capture volume Some
35. dit Defragment Trajectories You can now fill the gaps in the trajectories as described below NAVIGATION PUBLICATION E2 ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS Fill Gaps small gap fixing After defragmenting you may find that you have gaps in your trajectories where the fragments were joined Because gaps in defragmented trajectories are common problems the tools available for fixing them are comprehensive giving you complete control over how you handle them The tools are all found in the Edit menu though you will also use the tools in the Workspace menu to find the gaps After defragmenting you may find that you have gaps in your trajectories where the fragments were joined Because gaps in defragmented trajectories are common problems the tools available for fixing them are comprehensive giving you complete control over how you handle them The tools are all found in the Edit menu though you will also use the tools in the Workspace menu to find the gaps Fill a single gap e Select Workspace Find Next Gap to locate the next break in the selected trajectory Workstation centres on the break and selects the point on either side e Select Edit Fill gaps in name of selected trajectory Workstation fills the selected gap using a cubic spline interpolator Fill several gaps in a selected trajectory e Select a trajectory with a gap e Select Edit
36. e Plates viewing in 3D Workspace 24 G General Capture 34 Green stick figure sudden change of 52 Intersection Limit 19 and crossovers 47 L Label markers 12 Labelling multiple trajectories 28 trajectories 27 Loss of calibration 48 M Markers unlabelled 48 Max Accn 19 Max Noise Factor 20 Maximum vector 18 Maximum Deviation 33 Maximum Fill Gap 57 Maximum Overlap 33 Minimum vector 18 Movie window 35 Multiple gaps filling 57 N No Restriction 56 gt ESSENTIALS OF MOTION CAPTURE 60 VICON INDEX MOTION SYSTEMS O Occlusion definition 16 Open Database 04 Optimise reconstruction parameters 16 P Phantom 46 Pipeline 40 offline processing 43 Play Range Sliders 23 Post Triggering 35 Predictor Radius 19 and crossovers 47 Primary post trigger delay 35 Problem diagnosing cause of 47 types of 46 Process in Chunks 33 Processing log 43 R Reconstruction Parameters about 16 as cause of problems 46 optimising 16 recommended values 07 Reconstruction quality segment count 17 Reconstruction Volume 18 Residual Factor 18 S Sample Skip 35 Save range 23 trial 45 Save batch processing 43 Secondary post trigger delay 35 Segment count 17 causes of 17 Show Trajectories 49 Single gap fill 56 Single point deletion 57 Static Trial 10 gt ESSENTIALS OF MOTION CAPTURE VICON INDEX MOTION SYSTEMS 1 Time Bar 21 Trajectory defragment 49
37. e interested in using captured motion for animation BodyBuilder includes its own comprehensive user manual that describes the editing and modelling tools in detail Please refer to this manual for further information about editing and cleaning data with this product NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE VICON INDEX MOTION SYSTEMS A Always Refresh 25 Analogue window 26 Autolabel Calibration 29 checking results 15 Autolabel parameters 32 recommended values 09 Autolabelling 29 B Batch processing 43 Blooming 10 BodyBuilder for data editing 58 C Calibration loss of 48 quality and segment count 17 Camera Positions viewing in 3D Workspace 24 Camera Rays viewing in 3D Workspace 24 Camera sensitivity 09 Capture dynamic trial 13 next trial 41 static trial 10 Clean up using BodyBuilder 58 Continuity Chart 26 Copy pattern 57 Crossover 49 definition 47 fixing 49 locating 47 D Default Marker Set 35 Defining a new Subject 29 Defragment Trajectories 52 Delete a single point 57 trajectory 51 unlabelled trajectories 50 Dynamic trial capture 13 gt ESSENTIALS OF MOTION CAPTURE VICON INDEX MOTION SYSTEMS E External post trigger delay 35 F Find Next Gap 49 Fix large gaps in trajectories 57 small gaps in trajectories 56 Fix crossover 49 Flicker Free 25 Floor and Furniture viewing in 3D Workspace 24 Forc
38. e of a poor quality with a poor reconstruction too many ghost markers or markers swapping See Data Processing It is important when you place the asymmetrical markers on your subject so that they are significantly asymmetrical If they are not then there may be markers patterns that are very alike in the 3D Workspace and this which will confuse the autolabel process Marker placement is described in Preparation If the attachment points of the markers on your subject move significantly i e because of loose clothing or poor attachment you will find that the patterns in your subject s autolabel calibration no longer match the actual marker locations on your subject In this case you will need to create a new autolabel calibration If you created the autolabel calibration from a frame of data that did not have all the markers present and labelled then you will need to go back and re create the autolabel calibration As stated above in the cases where poor data or calibration is suspected to be the reason that you got poor auto labelling you will have to recapture or recalibrate to try and improve matters Autolabel parameters There are three Autolabel Parameters that can be adjusted to aid the system in auto labelling your trial from a given subject calibration The default parameters NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE AUTOLABELLING VICON MOTION SYSTEMS How the Au
39. e of trial e g Dynamic Trial Click OK to close the dialog In the capture pane select Video data only In Default Duration select Indefinite Under Default Marker Set enter the Marker diameter in millimetres for the markers you are using Under Options select Include subject names in labels and Select default or last used subject are the only options selected Click Pipeline Click to highlight Reconstruct Click Options Ensure that the settings in the Reconstruction Parameters dialog are as shown in the figure above NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE i THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Checking camera sensitivities prior to capture e Click OK to close this dialog e Click to highlight Label e Click Options This opens the Autolabelling Parameters dialog RECOMMENDED VALUES FOR Parameter Name Value PARAMETER SINI TUE 7 TEPEE a AUTOLABELLING PARAMETERS Maximum Deviation 3 BRIG Maximum Overlap 30 fields Process in chunks of Clear check box O fields e Ensure that the settings are as shown in the table above e Click OK to close the dialog e Ensure that Reconstruct and Label are the only options selected in the Pipeline dialog e Click OK to close the Pipeline e Click OK to close the Trial Types dialog You may need to adjust camera sensitivity at this stage because the calibration objects use larger
40. edictor Radius is half the minimum marker separation about 30mm for normal human movement analysis If you are using large markers you may need to increase in the Intersection Limit More about the Intersection Limit is described below The Max Accn parameter relates to how fast your subject is accelerating This parameter is used when starting new trajectories For most scenarios the maximum acceleration should be left at the default value of 50 mm s s If it is set too low new trajectories will not start resulting in missing data too high and points may be assigned to the wrong trajectory especially when many markers are in close proximity Increase both Max Accn and Predictor Radius for fast or erratically moving subjects for example when analysing golf swings and decrease them for slow ones The Minimum cameras to start trajectories helps eliminate noise from stray reflections marker ghosting and can speed up reconstruction when you have a lot of cameras In configurations where few cameras are expected to see each marker it should be set to zero one or two Please note that you should always use zero as a Starting point and only increase this number if you feel confident that you are getting excessive camera contribution to marker trajectory reconstruction Also positioning cameras at steeper angles say about 38 degrees can help reduce co linearity in feet and hands The average calibration residual see calibrating the Sys
41. end of a trial and it may be prudent to remove these data rather than allow them to lower the quality of the whole trial or to cause problems with other editing processes such as defragmentation To delete a single point e Locate and select the point in the trajectory NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS e Select Edit Delete Point The point highlighted with a white cross is deleted To delete a range of points e Select the first point in the range e Holding down the control key lt Ctrl gt select the point at the end of the range e Select Edit Delete Points This will leave you with a gap in your trajectory For single points or short gaps you can perform the deletion and fill the gap by cubic spine interpolation e Select the point or range to be deleted Select Edit Delete and fill Using BodyBuilder for data editing BodyBuilder is a companion to Workstation that if purchased enables you to edit and manipulate Vicon data Key features are e Edit modify and create new points and trajectories e interpolate broken trajectories e Filter and resample data e Create kinematic models and calculate model parameters e Model body segments and joints e Export results to ASF format for import by animation packages These features combine to make BodyBuilder an important tool for those interested in biomechanics and thos
42. ensibly positioned and in NAVIGATION lt Vv HII PUBLICATION ESSENTIALS OF MOTION CAPTURE VIEWING DATA VICON MOTION SYSTEMS Movie Analogue Data troubleshooting reconstruction problems This window displays each trajectory as a horizontal line Below each line are a number of dots each dot representing the contribution of a camera to the reconstructed data in that frame Thus you can easily find which cameras are contributing to a particular trajectories reconstruction Breaks in the solid line indicate that the trajectory could not be reconstructed at that point in time This is very useful when trying to solve problems with reconstruction For example if one camera never contributes to any trajectory then it is either poorly placed not well calibrated or has a mechanical or electrical problem At this point you could decide to check the camera directly using the Video Monitor window Live Monitors and or check the calibration data for that camera The Movie Window displays captured Movie data in MPEG or AVI format See Movie Capture for more information See Capturing Analogue Data in System Options NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE LABELLING THE DATA VICON MOTION SYSTEMS Manual labelling The Mode pane found below the list of labels at the foot of the Labelling Control Bar Corre
43. f horizontal video lines The Datastation receives signals representing these lines and sends coordinates of the lines to the Workstation The Workstation application uses these to calculate a central coordinate for the marker called a centroid How the calculation is done depends on the number of video lines e lf there is only one or no video lines then no centroid is calculated e If there are two video lines then the centroid is calculated from a simple cross algorithm e lf there are three or more video lines then the centroid is calculated using a more precise circle fit algorithm To get the best possible three dimensional data all markers in each camera view would have at least three video lines of data representing a stable circular shape You can view these lines using Diagnostic Mode in the Live Monitors view for live data and in the Video Monitor for captured two dimensional video data With the Live Monitor or Video Monitor open Select View Diagnostic Mode In this window you should see some markers represented by a number of horizontal lines If you cannot see this then you can change the view e Click and drag with the left mouse button to move the view up and down or left and right e Click and drag with the right mouse button to zoom in and out By moving the view and zooming in you should be able to locate a single marker and examine the video lines When you are finished using checking the quality of the video
44. f not taking enough care to set the apertures and sensitivities of cameras correctly Blooming occurs when a marker is close to a camera with a high sensitivity The system may interpret the high intensity of the reflection as two smaller markers and derive two false centres Flickering occurs in the opposite situation a marker some distance from a camera with low sensitivity It may appear to be coming in and out of view and the reconstructed point consequently flickers Merging is two markers quite close to each other appearing as a single marker There are two common causes two markers already close to each other being aligned in the view of one camera and too high sensitivity NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS Crossovers Occlusions versus poor parameters These problems relate in general to 3D data quality and cannot be used to clean data at this point If you have an excess of blooming flickering or merging you may need to plan your capture out more carefully and capture data again Crossovers occur during reconstruction when markers pass very close to one another and the two trajectories become collinear When they separate they may then be mislabelled swapping to the incorrect trajectory Crossovers are more likely to occur in trials where markers come in very close proximity to each other In general
45. for the static trial subject calibration NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE AUTOLABELLING VICON MOTION SYSTEMS Create a calibration from selected trajectories Defining a new subject Using a default subject You can also produce the subject calibration from a subset of trajectories This is useful if you wish to produce a separate subject calibration for multiple subjects in the same trial This additional subject may be another person or an inanimate object such as a prop To create an autolabel Calibration when capturing multiple subjects or a subject using a prop e Make sure all trajectories are labelled e Select the labelled trajectories for only one subject in the 3D Workspace e Continue with Autolabel Calibration as described above e In the Create Autolabel Calibration dialog ensure that Selected trajectories only is selected in the Trajectories pane How to capturing multiple subjects is described in more detail under Capturing Multiple Subjects in Advanced Techniques If you choose you can define a new subject and then create an autolabel calibration for this subject You may choose to do this if capturing data for the same subject under different circumstances or if markers have moved or fallen off Remember that the subject file contains data about the subject including the marker locations and marker set used e Select Trial Define Subjects
46. fter the capture is complete By default the 3D Workspace window will open even if it is no windows are selected Movie and Analogue options only become available if they are selected in the Capture panel For the general capture you need not select any of these options Under Default Duration you can select either a fixed or an indefinite time for capture If you select Indefinite then the system displays Start and Stop commands or enables triggering The Time Seconds option allows you to define a specific time for capture The time option is useful for static trials often used for subject calibration purposes When creating the Static Trial type a default duration of 3s was set for this purpose For General Capture select Indefinite The Default Marker Set box is by default empty and this option should be kept for the General Capture Trial Type This is very useful however to apply a marker set that is to be used for all trials of this type This saves you having to attach a marker set after capturing a trial You can type the path to the marker set required or use the Browse button to locate the mkr file on your system You can also set the size of the markers used on the subject This is used only for the display in the 3D Workspace and has no effect on the reconstruction itself Sample Skip is set to the default Video Rate Divider value of 1 This setting can be used to reduce the amount of data saved You might use this when cap
47. here are two options e Manually label good trajectories e Delete unwanted trajectories To manually label a trajectory e Locate and select the trajectory e Click on the label name in the Labels list To delete an unwanted trajectory e Locate and select the trajectory e Select Edit Delete Trajectory If you are certain that all the unlabelled trajectories remaining are ghosts and phantoms you can delete them all together e Select Edit Delete Unlabelled Trajectories As discussed above trajectories may break during reconstruction resulting in more segments trajectories than you actually have on your subject In some NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS Crossovers cases the trajectories are portions of the same trajectory that are merely separated by a break in the data and their position in time For example if the shoulder marker is reconstructed for several frames then occluded for a couple of frames and then is reconstructed again for several frames then two trajectories will be created One trajectory will be created for the shoulder marker before the break and one for the shoulder marker after the break Since by default the autolabel routine tries to label each frame of data both trajectories will be labelled as the left shoulder You can see the number of such trajectories immediately after autolabell
48. if markers are placed correctly a good calibration is obtained and suitable reconstruction parameters are used then they should not be an issue The Intersection Limit and Predictor Radius are key parameters in avoiding crossover problems Diagnosing the cause of problems If only two or three cameras are contributing to a reconstructed trajectory then it is likely that the break is due to an occlusion If you there are several cameras contributing then poor reconstruction parameters is the probable cause There are two simple ways to assess the number of cameras contributing to a reconstruction The first is to use the View Camera Rays and View Cameral Positions features both found in the View menu when the 3D Workspace window is open e Open atrial that has been reconstructed e Select a trajectory of interest e Select View Camera Rays A number of straight lines appear attached to the trajectory you have selected The lines are colour coded in the same order as markers and indicate which cameras are contributing to the reconstruction To identify cameras select View Camera Positions and zoom out to see labelled circles representing cameras As you step through the trial you will see rays disappear when no contribution is being made The second is to use the Continuity Chart e Select Window New Continuity Chart This displays trajectories as straight lines below which are displayed series of dots The dots indicate the number of
49. ils on using Eclipse see Managing Vicon Data in the Reference section First check that the system can view the calibration objects and that settings are correct e Place the L Frame in the middle of your capture volume e Select System Live Monitors and visually inspect each camera to check that it can only view the four markers of the L Frame e f there are additional reflections these need to be eliminated either by removing them covering them or if necessary adjusting camera sensitivities strobe intensities or camera apertures see Preparation NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Calibrate the system Create Trial Types e Verify that the L frame can be fully seen by at least two cameras e Select View Diagnostic Mode and adjust camera sensitivities until you have at least three lines of video per marker video lines are stable and represent a sphere Details of using the Live Monitors in diagnostic mode are given on page 15 To perform the calibration e Select System Calibrate Cameras to open the Calibrate Cameras dialog e Ensure that all of the cameras are selected even if it lists more cameras than you know you have connected to the system e Under Reference Object ensure that the correct Calibration Reference Object file e g example cro is selected and that the appropriate name of y
50. ime Seconds and enter 3 in the edit boxes e Under Default Marker Set enter the Marker diameter in millimetres for the markers you are using e Under Options select Static trial and Include subject names in labels are the only options selected e Click Pipeline e Click to highlight Reconstruct e Click Options This opens the Reconstruction Parameters dialog RECOMMENDED VALUES FOR Parameter Name Value eee Minimum Vector X 3500 Eem PARAMETERS Minimum Vector Y 3500 Minimum Vector Z 100 Maximum Vector X 3500 Maximum Vector Y 3500 Maximum Vector Z 3000 Max Accn mm s s 50 Max Noise Factor 7 Intersection Limit mm 12 Residual Factor 2 Predictor Radius 30 Min Cameras to start O NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Parameter Name Value trajectory Non circular markers Discard Ensure that the settings in this dialog are as shown in the table above More details of reconstruction and reconstruction parameters are given on page 16 Click OK to close this dialog Ensure that Reconstruct is the only option selected in the Pipeline dialog Click OK to close the Pipeline Click OK to close the Trial Types dialog Create a Trial Types for a dynamic trial Select Trial Trial Types Click New Enter a name for the typ
51. ing A number to the left of the label in the Label List will indicate the number of such similarly labelled trajectories The process of combining these multiple trajectory fragments into one long trajectory is called defragmenting You should always defragment any fragmented trajectories Before defragmenting however you may want to look at the fragments and verify that the have been labelled correctly If there are no such breaks then the number next to each label being used should be 1 If you have fragmented trajectories you can join them together using the Defragment command e Select Edit Defragment Trajectories All trajectories with the same label are joined together by aligning them This can be easily seen by looking at a fragmented trajectory in the Continuity Chart as you defragment A message will appear after defragmenting indicating how many trajectory fragments were joined and if any overlaps resulted Where overlaps in trajectories occur the overlap is saved as a separate trajectory with a label based on the original You may then delete this or if mistakes have been made such as mislabelling use it to repair the data You will want to use or remove overlapping trajectories before moving on To delete an overlapping trajectory e Find and select the trajectory in the Continuity Chart e Go to Edit Delete trajectory lt overlapping trajectory name gt Note that when the trial is saved to disk trajectories are automati
52. int and the matching point on the first trajectory are exchanged creating a crossover Of course this feature is really designed for fixing crossovers but this will give you an idea of what you are looking for If the crossover occurs at a single point then you may be able to fix it using the Exchange Points command e Select one of the crossover trajectories e Select the second crossover trajectory e Select the second trajectory at the point where the crossover occurs e Select Edit Exchange Points If you select the correct point then the crossover will be fixed directly If you are unable to locate the crossover point easily or the crossover is more complex you will need to ship the trajectories relabel and then defragment This example assumes a crossover between two markers LFIN and LTHI and is illustrated over page NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS Schematic diagram of fixing a cross over error LTHI Snip Snip both trajectories 7 LEIN _ y IN THI Relabel the segments defragment and fill gaps J e Select the first trajectory e g LTH at a position just before the crossover starts e Hold down the Control key and select the same trajectory just after the crossover e Select Edit Snip Trajectory LTHI This removes all points between the two selected Repeat this for the
53. ion is Capture Next Trial This is usually used in NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE THE VICON PIPELINE VICON MOTION SYSTEMS conjunction with a trial type This option can be a practical solution to the problem of having to capture a lot of data in a short time when you know the moves to be made and you do not have time to process and clean up data while in the studio You may be able to find the Repeated Capture type in the list in the Trial Types dialog To view the details of this trial type e Select Trial Trial Types e Select Repeated Capture from the Trial Type drop down list If you do not see this trial type you may want to create a new one with the options discussed below For more details on creating Trial Types please reference the previous chapter e Click Pipeline The Pipeline dialog opens If necessary scroll down until you find the single selected item Capture Next Trial Now e Select the text Capture Next Trial so that it is highlighted in blue e Click Options This opens the Capture Next Trial options dialog This offers two options Display Trial Capture dialog If you select Display Trial Capture dialog after the trial capture is complete the Trial Data Capture dialog will be displayed automatically allowing you to confirm or change the settings before capturing the next trial This saves time and keystrokes Use settings from la
54. ion residuals For residuals of 2mm or less the recommended Intersection Limit is 12 If this is higher it may lead to more crossovers in your data The recommended value for the Predictor Radius is half the minimum marker separation normally around 30mm for normal human movement A high value can lead to more crossovers Viewing trajectories Before editing data it will be useful to familiarise yourself with methods of viewing trajectories One of the easiest ways is to use the Continuity chart Because each trajectory is presented as a straight line it is simple to scan through and see where breaks occur When fixing breaks however it is useful to be able to see the shape of the trajectory To do this view the 3D Workspace and use the two small sliders on the main slider to extend the range of visible trajectory When you use the Find Next Gap command Workstation automat ically extends the visible range to 10 frames It is useful to zoom in and look closely at the breaks in a trajectory though you may find the presence of all the other trajectories confusing You can display only selected trajectories e Select Workspace Hide Other Trajectories If no trajectories are initially displayed e Click to select the desired trajectories e Select Workspace Show Trajectories NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS You can also se
55. lect trajectories using the Labels List in the Labelling Control Bar e Click Select in the Mode panel at the foot of the Labelling Control Bar e Select the label names in the Label List for trajectories you wish to view e Select Workspace Show Trajectories To hide only selected trajectories e Select Workspace Hide Trajectories To hide all trajectories e Select Workspace Hide All Trajectories To display all trajectories e Select Workspace Show All Trajectories Another useful tool is the Select Centre command When you zoom in to view the workspace at close quarters and drag to rotate the view the rotation still occurs around the centre of the Workspace which can result in you losing the subject from view altogether You can see the centre of rotation as a purple marker when Rotation Centre is selected in the View menu You can make a specific marker the centre of rotation so that any rotation occurs around that marker and you do not lose the subject from view e Select the marker to use as the centre of rotation e Select Workspace Select Center The centre of rotation is moved back to the centre of the Workspace when you click Play in the Time Bar Editing 3D Data The first part of this section describes how to reconstruct and autolabel your data If you have perfect 3D data then you are ready to go on to the next step of visualising modelling analysing or applying your data to an animated character If however
56. markers than you normally use for capture Adjusting the sensitivity will not affect the system calibration Also note that you should only need to perform these checks once at the start of your capture session e Have your markered subject stand in the Capture Volume e Select System Live Monitors e Select Camera 1 e Have the subject walk to the edge of the Capture Volume furthest from Camera 1 e Select View Diagnostic Mode e Adjust Camera Sensitivity to the point that visible markers are stable and have at least three lines of video data e Have the subject walk to the side nearest Camera 1 NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE 2 THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Capture Data Static Trial View the trial in the 3D Workspace e Ensure that the markers are still spherical and are not blooming When markers are reflecting too much light their image in the camera will sometimes distort This causes the captured shape to be non circular This is called blooming By default the system discards all data from non circular markers If you need to reduce camera sensitivities to keep markers from blooming then you should check that markers are still visible when the subject moves to the far side of the Capture Volume e Continue the same checks on each of your cameras in turn More details on using the Diagnostic Mode of the Live Monit
57. moving near the edge of the capture volume then they may accidentally walk out and back inside This is easy to spot since you will be able to see this during playback The solutions to this are either recapture the trial or remove the unwanted data The latter can be achieved by using the save range markers on the Time Bar Ruler Visual inspection should tell you whether an unlabelled trajectory is useful data missed by the autolabeller or a phantom or ghost trajectory Unlabelled trajectories are white whilst labelled trajectories are light blue Phantoms and ghosts may be less obvious as they only appear for short periods and may be far from the main subject or lost in the mass of other trajectories Fortunately Workstation has tools to locate them for you The following instructions assume you have reconstructed and labelled your data as described in the sections above If there are no unlabelled trajectories in your trial then the menu options and icons discussed below are greyed out e Click the Next Unlabelled Trajectory icon e Select Workstation Next Unlabelled Trajectory e Press F10 Any of these will locate and select the next unlabelled trajectory and highlight in yellow If you think you have missed a trajectory locate the previous unlabelled one e Click the Previous Unlabelled Trajectory icon e Select Workspace Previous Unlabelled Trajectory e Press Shift F10 NAVIGATION lt Vv III
58. nsistency during capture sessions because you only have to select the Trial Type to load the settings you desire You can also speed up processing because a Trial Type can include settings in the Vicon Pipeline Trial Types have already been created and used when performing the captures in The Motion Capture Process at the start of this section For the purpose of capturing a static trial you created or selected the Static Trial type which automatically captures for three seconds only For the subsequent capture you used the Dynamic Trial type This allowed you to capture for as long as necessary and then reconstructed the data automatically The Dynamic Trial type is an example of a trial type that includes some pipeline options The Pipeline can also be used on its own and is described in detail in the following chapter Trial Types are defined using the Trial Types dialog opened from the Trial menu or from the Trial Data Capture dialog Default trial types General Capture A number of trial types are included with the Vicon installation They have been provided as examples but can be modified as you see fit You can also delete trial types and create new ones If some of the trial types described below are not on your system or have been modified you can re create them by following these instructions and using the table below as reference The General Capture trial type is included with the system as an example of a very simple trial type
59. ors is given on page 16 A static trial is used for Subject Calibration In preparation for the Subject Calibration ask your subject to take up a neutral pose in the centre of the capture volume This pose should be standing head level feet forward and arms at the sides with palms facing in You can now capture data Note that for some third party applications or modelling a specific pose is required in setting up the data to process Check with the documentation of the application you are using for details on poses If you are not sure the neutral pose described above is a good starting point e Select Trial Capture or click the New Trial button in the Data Directory to open the Trial Data Capture dialog If you cannot start a trial check that your session is open You must have an open session in order to capture data To open a session double click on the session name You should now see the name of the session in the right hand side of the Status Bar e Under Trial Type select the Static Trial you have created e Under Reference enter the name you wish to use for the trial e Click Capture Warn the subject that capture is about to begin and that they should stand still in their neutral pose When ready e Click Start The system captures data for three seconds and begins reconstruction On completion the white circles representing markers appear in the 3D Workspace The 3D Workspace is automatically opened after the capture sto
60. our calibration object is specified If you are unsure which calibration objects you have refer to the diagram in Vicon Hardware e Inthe Calibration panel ensure that Capture is set to all new data e Click Calibrate The Data Capture Calibration Static dialog opens When you are ready e Click Start e When the Data Capture Calibration Dynamic dialog appears remove the L Frame e Ensure the wand is in the volume e Click Start e Perform the wand wave e When you have completed the wand wave click Stop Complete information on calibrating the system is presented in Preparation The Trial Types feature allows you to set all the parameters for capturing a trial This means that you can save these settings for future use In this section you will create two trial types one for capturing a static trial and one for capturing a general dynamic trial You may find that these trial types have already been created In this case you can use the instructions below to verify the settings in the trial types are correct NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE 6 THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Create a Trial Type for a static trial e Select Trial Trial Types e Click New e Enter a name for the type of trial e g Static Trial e Click OK to close the dialog e Inthe capture pane select Video data only e In Default Duration select T
61. ps You can see the floor represented as a grid A set of axes indicates the NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Attach a Marker Set orientation of the view as defined by the calibration You should also see the captured markers represented by white circles If you do not then it may be that they are just not visible at the beginning of the trial The Time Bar can be used to replay the trial display specific frames set the range of interesting frames or to set up events To view the trial use the Time Bar at the foot of the main window e To start replay click Play or press the Ctrl key and the Right Arrow at the same time e To stop the playback click Stop or press the space bar Alternatively you can drag the large rectangular cursor in the Time Bar ruler A more detailed description of data viewing options is given on page 21 So that the system can associate captured markers with known positions or labels you must first associate a marker set with the current trial The marker set must be compatible with the markers you have attached to the subject If you have used the arrangements of markers described in Attaching Markers then you can use the file HumanRTkm mkr To attach the marker set e Select Trial Attach Marker Set e Locate and select the file HumanRTkm mkr in the Models sub folder of the main
62. reaks in trajectories many trajectories do not exist for the whole trial The autolabeller looks for patterns of trajectories that co exist or overlap for at least the number of fields defined by the Minimum Overlap parameter The default value is 30 fields If the trial is short and very fragmented then you could reduce the overlap If it is a long trial with a large number of continuous trajectories then increase the overlap value The autolabeller scans through the whole trial to determine the relationships between the markers For long trials this can take time The Process in chunks option allows you to break this down into smaller sections and this increases the speed of the processing The downside is that this increases the risk of not being able to label every trajectory The default setting is to have this option clear This means that the autolabel process will attempt to label every frame of data For very long trials with good quality data you may get good auto labelling results faster with values between 100 and 300 NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE TRIAL TYPES VICON MOTION SYSTEMS General Capture Trial Type name There are many parameters and settings that are used to control a trial capture Using the Trial Types feature you can store these settings to use for any capture session for which they are appropriate This saves time and gives co
63. rial Type drop down list e Ensure the correct subject is selected in the Subjects list e Add a description and notes in the appropriate edit boxes e Click Capture e Warn your subject that you are about to start capturing data e Click Start e When the move is complete click Stop NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Because of the options you chose in the Trial Type pipeline you will see the reconstruction process taking place when the capture is stopped The Autolabelling process will follow this You will know this is complete when the green stick figure appears in the 3D Workspace window For more information on automation see Trial Types Page 34 and the Pipeline Page 40 NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE CHECKING THE QUALITY OF THE VIDEO DATA VICON MOTION SYSTEMS How Vicon produces the video signal Using the Diagnostic Mode When to use the diagnostic mode Three dimensional Vicon data is produced by the combination of two dimensional data from each camera You can only ensure high quality results by capturing high quality two dimensional data Therefore it is important to check the quality of the video data at the start of each motion capture session The camera sensor plate senses reflected light from the markers as a series o
64. ries have been labelled e You forget to create an autolabel calibration for your subject e Check that the correct subject has been selected for the trial Trial Options NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE AUTOLABELLING VICON MOTION SYSTEMS e The trial itself may be of a poor quality with a poor reconstruction too many ghost trajectories or trajectories swapping e The subject calibration may be poor this can be the case if you are using frames where some markers are occluded or even missing e The Autolabel Parameters may be incorrect see below In the cases where poor data or calibration is suspected to be the reason that you got poor autolabeling you will have to recapture or recalibrate to try and improve matters If it turns out that your subject calibration is poor you will need to create a new one It is important to verify that the frame you are using to create the autolabel has all markers present and labelled Refer to the section above for more information on creating the autolabel calibration If some trajectories remain unlabelled or trajectories are labelled incorrectly the following may be reasons e The patterns in your autolabel calibration are not unique e Markers have moved since the autolabel calibration was created e The autolabel calibration was not created from a completely labelled frame of data e The trial itself may b
65. rple blue and then back to yellow You can select up to twenty markers at one time e Click on the label corresponding to each selected marker in the same order As before the trajectories should turn light blue when labelled Manual labelling can be tedious particularly when trajectories are broken in several places To automate the process use the autolabel feature To label more than one subject in a trial using the same marker set see Capturing Multiple Subjects in the Advanced Capture Techniques section NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE AUTOLABELLING VICON MOTION SYSTEMS Calibrate a subject from a static trial Calibrating from dynamic trials Preparing the Autolabel feature involves taking a manually labelled trial and assigning it to a subject Behind the scenes the system stores the patterns of the marker locations on a particular subject This process is called autolabel calibration or subject calibration and the patterns are stored in your subject file In subsequent trials Workstation compares the patterns of markers in the 3D workspace in order to identify individual trajectories and label them automatically Before creating the subject calibration you must have captured and manually labelled a trial A static trial will most often be used for this purpose though in principle you can use any trial Autolabel calibration To calibrate a subje
66. s accidentally moved you will see additional reconstructions causing the segment count to increase This is why it is useful to calibrate your volume at the start and end of a capture session If you find you have poorly reconstructed data and this is rectified by applying the later calibration it would imply that one or more cameras have indeed moved during the session Optimising Reconstruction Parameters The reconstruction parameters are edited in the Reconstruction Parameters dialog This allows you to control several parameters These are described below but you can see how these affect the reconstruction using any of the sample data in the examples Vicon Examples database or your own data Because to raw 2D video data the TVD file is always available as the complete source data for reconstruction you should feel comfortable to experiment with different Reconstruction Parameters to find the ones that are optimal for your activity volume and calibration In fact you may want to make a practice of doing a test capture any time you change your activity or volume size significantly This will allow you to find the optimal reconstruction parameters and verify camera placement before your subject arrives The Minimum and Maximum Vector values are the dimensions of the Reconstruction Volume in millimetres you can view this as a purple box in the workspace by selecting View Reconstruction Volume For best results and fastest reconstruction yo
67. st captured trial Selecting Use settings from last trial causes the system to move directly onto the next trial start dialog This new trial uses the settings already entered and automatically augments the trial name by one When you have finally completed your set of captures click Cancel in the Data Capture dialog to break the cycle Set Pipeline options Most of the options available in the pipeline dialog have their own set of parameters The dialogs used to control these parameters are available from within the pipeline dialog itself using the Options button For example to set reconstruction parameters e Select Trial Pipeline e Select Reconstruct so that the text is highlighted NAVIGATION PUBLICATION S2 ESSENTIALS OF MOTION CAPTURE THE VICON PIPELINE VICON MOTION SYSTEMS Running a pipeline on an open trial Offline processing with the pipeline e Click Options Complete the dialog as you would normally do so and close to return to the Pipeline dialog Note that when you select an option some explanatory text appears in the panel at the bottom of the dialog window The pipeline can be used on an individual trial To run selected pipeline options on an open trial e Select Trial Pipeline to open the pipeline dialog e Select the options you wish to run e Click Process Now If you were to use atrial type such as the Repeated Capture example you could produce a lot
68. st used subject The former does exactly what it says and whenever you use the Mouse Helper to identify a marker or trajectory the subject name will appear in the pop up in addition to the marker label This is especially useful if you have more than one subject The latter is more often used when performing repeated captures using the same subject so that you do not have to continually reselect the subject Static Trial is used by some processing operations as a flag in certain calculations for which it may be useful to know whether or not the subject is moving NAVIGATION l gt PUBLICATION ESSENTIALS OF MOTION CAPTURE TRIAL TYPES VICON MOTION SYSTEMS Default trial type settings Rename a Trial Type Cue Capture from Audio file allows audio data to be used alongside the capture and the capture may be cued from any point in the audio file or an audio file may be started at a preset point during the capture Default Trial Types More examples Try selecting different Trial Types from the drop down list you will see the settings for each change The trial types available depend on your system The default settings for some of these are detailed in the Table below Type Capture Open Windows Default Options Duration General Video None Indefinite None Movie only Movie Movie Data Indefinite None Pipeline Video 3D Workspace Indefinite Include Subject names in Capture labels
69. subsequent trials Capture a dynamic trial e Select Edit Unlabel all trajectories e Select Trial Options e Verify your subject is selected e Click OK The name of the subject and the list of markers will appear in the Labelling Control Bar on the right of the Workstation window e Select Trial Autolabel or click the Autolabel button from the toolbar The labelling may take a few moments to complete and if successful the green stick figure will be drawn After the Autolabel is complete check that the left and right side are marked are correctly You can do this by holding the mouse cursor over any labelled trajectory to view the label assigned in the mouse helper window As you become more familiar with the system you will begin to recognise the green stick figure If the markers are not labelled correctly and or the stick figure does not appear correct please refer to the Autolabelling chapter Page 30 for troubleshooting details Whenever you capture a new trial you can select the Subject in the Trial Data Capture dialog When you do this the subject file will be associated with the trial and there will be no need to select it in the Trial Options dialog before autolabelling You can also use the Pipeline feature to label the trial after reconstruction To capture a dynamic trial e Select Trial Capture or select new trial from the Eclipse Data Directory window e Select the Dynamic Trial type that you created from the T
70. t system To create a new Eclipse database e Start Workstation form the Windows Start Programs menu e Select File New Database e Click to open the Browse dialog e Navigate to the location where you wish to create the database and click OK e Enter a Name and Description for the database e Select one of the templates lt Name of Template eni gt NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Check the system e Click Create The Open Database dialog now opens with the new database selected in the displayed list e Click Open You can now build the database hierarchy The nomenclature used by Eclipse depends on the template used For Science and Engineering users e Click New Patient Classification and enter a name e Click New Patient and enter a name e Click New Session and enter a name For Entertainment and Animation users e Click New Project and enter a name e Click New Capture Day and enter a name e Click New Session and enter a name If you are using the Generic template e Click New Top Level and enter a name e Click New Subject and enter a name e Click New Session and Enter a name To use an existing database choose Open Database from the file menu and select the database from the Open Database dialog If the database is not listed then click Browse to locate the database For more deta
71. tem influences two reconstruction parameters These are Intersection Limit and Residual Factor Intersection Limit is used to define the upper limit on the separation of the rays from two cameras in order for them to contribute to the reconstruction of a marker It should be set to 12 for calibration residuals around 2 0mm or less but increase it for higher calibration residuals and reduce it if trajectories start to crossover or fail to start The Residual Factor should be set such that multiplying by the Intersection Limit and then dividing by the average camera residual yields a result between 3 and 10 Higher values will cause fewer ghost trajectories to be generated but may produce spiky data as points are assigned to the wrong trajectories lower values may give more accurate trajectories but are likely to produce more ghosts NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE RECONSTRUCTING 3D DATA V CON MOTION SYSTEMS Hints for improving trajectories If there are too many trajectory breaks or trajectories fail to appear at all try increasing the Max Noise Factor default value 7 the Intersection Limit or the Predictor Radius If there are too many mismatches or crossovers try reducing these parameters You should probably make a practice of only changing one parameter at a time however so you can determine the cause of the effect NAVIGATION lt
72. times the captured data is incomplete some markers not being seen by at least the two cameras required to calculate the position of each marker for each frame When a marker is obscured from view it is called an occlusion This results in broken trajectories Sometimes markers are so close in the view that the calculation mistakes one for another resulting in a phenomenon known as a crossover Sometimes the calculation produces trajec tories for markers that are not really there these are known as ghost markers You can improve the reconstruction process by optimising the Reconstruction Parameters Outcome Reason Notes The correct Good calibration no occlusions number of correct reconstruction trajectories parameters Too few Occlusions Markers blocked from view throughout trial trajectories Missing markers Markers have fallen off during trial Improper reconstruction parameters Too many Occlusions Intermittent occlusion means reconstruction trajectories cannot occur for some frames leading to breaks in the trajectory These fragments are initially counted as separate segments Improper reconstruction Reconstruction parameters mean that parameters reconstruction cannot occur in all frames leading to breaks and more segments as above Ghost trajectories Poor calibration results or reconstruction parameters can lead to false reconstructions showing up as extra trajectories N
73. to the label in the Labels List Moving the mouse over the marker now displays the label in the small pop up window You can now continue selecting and labelling the markers You will find as you continue you probably have to move around the figure zooming in and out to make sure you can identify individual markers You will also see that as you label more markers the green stick figure appears How this is drawn is defined in the marker set which includes lists of markers which combine to make body segments For more information on labelling see page 27 To create a Subject Calibration in the current session e From the Trial menu select Create Autolabel Calibration e Look in the Subject Name drop down list for the name of your subject e f you find your subject then select the name if not type the name in the Subject Name field e Under Field Range select Fields around current field and specify O e Click OK e Select File Save to save the trial including the labelling To check the Subject Calibration verify that the Autolabel feature works for your subject First save the trial e Select File Save This is a precaution should you have a system failure If this should happen then you will not have to re label your trial Now check the Autolabeller NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE THE MOTION CAPTURE SESSION V CON MOTION SYSTEMS Labelling in
74. tolabeller works Maximum Deviation Maximum Overlap Process in Chunks usually work well for autolabelling a variety of marker sets and subjects However in some cases adjusting the following parameters will improve your auto labelling results To open the Autolabel Parameters dialog e Select Trial Autolabel Parameters To understand these parameters it is helpful to know a little about how the autolabel feature works As the subject moves the separations and patterns between markers on any rigid body segment remain relatively constant while those between markers on different segments tend to change The autolabelling algorithm works partly by testing the separations between every marker and all the others during the trial looking for the patterns stored by the autolabel calibration in the subject file The following parameters control the execution of the autolabel feature Maximum Deviation Maximum Overlap and Process in Chunks Maximum Deviation is the percentage deviation allowed in the separation between two markers in the dynamic trial compared to the corresponding markers in the subject calibration The default setting is 3 Setting this too low may result in few trajectories being labelled too high may result in incorrectly labelled trajectories Increase Maximum Deviation if the autolabeller is failing to recognise segments where markers are close together or there is a lot of body movement Because occlusions cause b
75. tting on the screen is refreshed between frames showing the complete screen but slowing down the playback Other Windows A number of other windows are available for viewing the trial data in a different ways The Video Monitor is similar to the Live Monitor but shows the captured 2D data for each camera instead of the live view It is also different in that it has the Time Bar which works in the normal way and the Labelling Control Bar instead of the Camera Settings Bar Use the numbered buttons below the main window to select cameras to view all the View menu options available with Live Monitor also apply to the Video Monitor This is a great tool for trouble shooting reconstruction problems If you are having trouble reconstructing a marker in the 3D Workspace you may want to go to the 2D video to view the raw video for each camera If at least two cameras have captured the marker then you know the reconstruction problem lies somewhere in the calibration or reconstruction parameters If you do not find the marker in at least two camera views then the problem is in marker placement marker occlusion or camera positioning In the latter case the only ways to solve the problem are to recapture the data or mathematically create this missing data The Continuity Chart is only available once data has been reconstructed and shows which cameras contributed to the reconstruction of each trajectory Its main purpose is to check that cameras are s
76. turing slow moving subjects or capturing for long periods A video rate divider of 2 will halve the capture rate of your cameras 4 will quarter the rate and so on The effective capture rate is shown For General Capture this should be set to 1 Enable post triggering allows the capture of something that has already happened This can be used for capturing movements of unpredictable subjects or for unpredictable events A typical example would be the movement of young children or animals For the General Capture this should be left blank There are two main parameters Primary post trigger delay and Secondary post NAVIGATION lt N7 III PUBLICATION ESSENTIALS OF MOTION CAPTURE TRIAL TYPES VICON MOTION SYSTEMS Options trigger delay A third External post trigger delay allows you to control the delay if are using external triggering With post triggering enabled the Data Capture dialog includes two extra buttons marked with the values set in the Primary and Secondary post trigger delay boxes Data within durations specified is constantly being buffered by the system Therefore when the event occurs you trigger the capture but data within these periods has already been stored and is saved in the trial You stop the trial in the normal manner The primary and secondary settings allow you to choose at the time of capture how much data will be stored When you arm the system for capt
77. u can set this volume to just enclose your Capture Volume All data outside this volume is discarded by the calculation This means that sources of extraneous light such as stray markers or reflections from around the studio can be ignored If it is set too large reconstruction will be slower and ghost trajectories may appear too small and useful trajectories may be lost AS a reminder the actual volume in which you will be able to reconstruct data is the intersection between this Reconstruction Volume and the Calibration Volume It is recommended that the minimum Z be set below the lowest capture point to account for unevenness in the floor During the reconstruction the software tracks the position of each marker from frame to frame creating trajectories from marker position between frames The NAVIGATION lt Vv III PUBLICATION ESSENTIALS OF MOTION CAPTURE RECONSTRUCTING 3D DATA V CON MOTION SYSTEMS Subject Acceleration Camera Parameters and Positioning Calibration Quality important parameter for this is the Predictor Radius which sets a limit to the space used in predicting where a given marker may appear in the next frame If set to a large value the search can go further resulting in fewer breaks in the trajectory but may also associate an incorrect marker with the trajectory causing a swap If it is too small it results in more breaks The recommended value for Pr
78. ure the Data Capture dialog shows the Start button as three separate buttons Using the default settings of 5 and 10 seconds for primary and secondary delay these would be e Start used to start the capture without post triggering e 5s used to store data 5 seconds prior to the capture being triggered e 10s used to store data 10 seconds prior to the capture being triggered For example you might be studying the movement of a young child who has just learned to walk or want to apply such movements to a movie character The child will be sitting and encouraged by the mother to stand and walk You probably cannot tell when exactly the child will actually stand and start walking and so use post triggering You choose to use the default 5 and 10 second settings When you are ready you click Capture in the Trial Data Capture dialog and wait The child decides that they will stand and walk around the capture volume At this point you decide how much data before they stand you wish to save If nothing much has happened you click the 5s option If the child has been making a slow standing movement you might choose to save more and so select the 10s option When the movement has finished you click Stop in the usual manner It is important to note that this feature does not work with Movie capture Options offers four additional settings of which two are selected for General Capture Include subject names in labels and Select default or la
79. ves only an overview and you will be interested in which particular trajectories are broken There are three main reasons for high segment count Incorrect reconstruction parameters Incorrect choice of reconstruction parameters is a common cause of a high segment count and broken trajectories To optimise parameters you need to revisit the Optimise Parameters dialog See below Markers obstructed from view There are a number of situations where there is a higher risk that cameras may not be able to view all of the markers all of the time These include capturing multiple subjects using props or furniture in the Capture Volume subjects bending over or rolling on the ground There are a number of possible solutions You could e Reposition cameras to improve visibility e Use more cameras NAVIGATION lt PUBLICATION ESSENTIALS OF MOTION CAPTURE RECONSTRUCTING 3D DATA V CON MOTION SYSTEMS Reconstruction Volume Marker Size and Placement e Use extended markers so that they are visible more of the time e Use more redundant markers Redundant markers can be used in modelling or visualisation when other markers are occluded Poor calibration You will usually judge the quality of your calibration from the values of the residuals displayed in the Calibrate Cameras dialog You can however get an indication from the number of segments produced during reconstruction If a camera i
80. your data is not exactly perfect at this point then you will need to edit and clean it up some before moving on The general steps for cleaning and editing data are e Label any unlabelled trajectories of interest e Delete remaining unlabelled trajectories NAVIGATION PUBLICATION S2 ESSENTIALS OF MOTION CAPTURE CLEANING UP DATA VICON MOTION SYSTEMS Ghosts and phantom trajectories Defragment Trajectories e Check trajectory fragments e Defragment trajectories e Delete any erroneous overlaps e Check for crossovers e Check for gaps in data e Fill small gaps e Use Copy Pattern to fill larger gaps e Use Delete and Delete amp Fill to remove spurious data points in trajectories You may not need any of these steps or you may need them all depending on the state of your data It is important to remember that extensive data cleaning and editing can take a lot of time The Vicon system has been designed to give very clean data that requires little or no editing when used correctly If you find yourself doing a lot of cleaning and editing you may want to take some time and go over your capture set up and techniques as described in earlier sections It is often true that 30 extra minutes spent in optimising your camera set up and capture protocol saves numerous hours of cleaning and editing Having located unlabelled trajectories and decided whether they are useful data or ghosts and phantoms t
Download Pdf Manuals
Related Search
Related Contents
3-Phase ac BLDC High-Voltage Power Stage HIVERNAGE 40 CP 155 - Interempresas USE THIS MANUAL WITH: GSF1200/S SERVICE MANUAL (99500 none I 3063 Instructions / Assembly TNC 640 - Heidenhain Samsung S1050 Lietotāja rokasgrāmata Sensor Installation Manual TABLE DES MATIERES Manual SolarPak - Schneider Motobombas Copyright © All rights reserved.