1. e Ensure that the 4 adjustable castors are fitted with the protruding centre screw e Report any deficiencies to the distributor who supplied the appliance e Check that the available gas supply is correct to that shown on the rating plate located on the right hand panel Location Pp Installation must allow for a sufficient flow of fresh air for the combustion air supply 2 Installation must include adequate ventilation means to prevent dangerous build up of combustion products 3 Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble free operation The minimum installation clearances shown below are to be adhered to 4 Position the appliance in its approximate working position 5 All air for burner combustion is supplied from underneath the unit The legs must always be fitted and no obstructions placed on the underside or around the base of the unit as obstructions will cause incorrect operation and or failure of the appliance 6 Components having adjustments protected by manufacturer are only allowed to be adjusted by an authorized service agent They are not to be adjusted by the installation person Thor Fryer Manual 12082014 Page 6 Installation Clearances NOTE Only non combustible materials can be used in close proximity to this appliance Combustible Surface Non Combustible Surface Left Right Hand Side 355mm Omm Rear 250mm Omm Assembly NOTE e This appliance
2. supporting this control to absorb these shocks Wiring Diagram Pilot outlet Thernocouple Connection Interrupted Connector Thor Fryer Manual 12082014 Page 16 Explosion drawing GL165 P GL165 N GL166 P GL166 N Thor Fryer Manual 01112013 Page 17 Spare Parts List NO DESCRIPTION MODEL CODE QTY 1 Drain Extension a GEN 01 02 1005325 2 2 Combination Valve GE 01 20 1068561 1 GL165 P GL165 N 3 Valve Ball GL166 P GL166 N 01 20 1068560 1 GL165 P GL165 N 3 4 Burner GL166 P GL166 N 01 03 1015095 4 GL165 P GL165 N 5 Crumb Screen GL166 P GL166 N 01 11 1062050 1 Flame Device System S Does not include Ee GE 01 22 1069545 1 injector S ODS injector 0 01 GL165 P GL166 P 01 20 1068567 1 ODS injector 0 026 CLS N ECS 01 20 1068571 1 GL165 P GL165 N 7 Basket GL166 P GL166 N 01 10 1061027 2 8 Flue Rear GL165 P GL165 N 01 15 1066336 1 AMES GL166 P GL166 N 01 15 1066411 9 Fryer Restraint Chain SECH See 06 05 1472505 1 GL165 N 01 20 1068636 3 10 Orifi GL166 N 01 20 1068631 4 ep Ge 01 20 1068652 S GL166 P SE 4 11 Valve Connection Aie GER 01 18 1067440 1 12 Foot optional TR GE 01 02 1005382 4 High Temperature GL165 P GL165 N 13 Protector GL166 P GL166 N 03 99 1290101 1 g GL165 P GL165 N 14 Piezo Igniter GL166 P GL166 N 03 99 1290085 1 GL165 P GL165 N 15 Fixed Caster GL166 P GL166 N 01 02 1
3. the above Directive s and Standard s Ik de ondergetekende verklaar hierbij dat de hierboven gespecificeerde uitrusting goedgekeurd is volgens de bovenstaande Richtlinien en Standaard en Je soussign confirme la conformit de l quipement cit dans la pr sente la aux Directive s et Norme s ci dessus Ich der die Unterzeichnende erkl re hiermit dass das oben angegebene Ger t der den oben angef hrten Richtlinie n und Norm en entspricht ll sottoscritto dichiara che l apparecchiatura di sopra specificata conforme alle Direttive e agli Standard sopra riportati El abajo firmante declara por la presente que el equipo arriba especificado est en conformidad con la s directiva s y est ndar es arriba mencionadas Eu o abaixo assinado declaro que o equipamento anteriormente especificado est em conformidade com a s anterior es Directiva s e Norma s Date Data Date Datum Data Fecha Data Signature Handtekening Signature Unterschrift Firma Firma Assinatura Full Name Volledige naam Nom et pr nom Vollst ndiger Name Nome completo Nombre completo Nome por extenso Position Functie Fonction Position Qualifica Posici n Fun o 30 10 14 Richard Cromwell Commercial Director thor
4. 005320 2 GL165 P GL166 P 16 Universal Caster GL165 N GL166 N 01 02 1005319 2 Thor Fryer Manual 01112013 Page 18 DECLARATION OF CONFORMITY Conformiteitsverklaring D claration de conformit Konformitatserklarung Dichiarazione di conformit e Declaraci n de conformidad Declara o de conformidade Equipment Type Uitrustingstype Type d quipement Ger tetyp Tipo di apparecchiatura Tipo de equipo Tipo de equipamento Model Mod le Modell Modello Modelo Malli Application of Council Directives s Toepassing van Europese Richtlijn en Application de la des directive s du Conseil Anwendbare EU Richtlinie n Applicazione delle Direttive Aplicaci n de la s directiva s del consejo Aplicac o de directiva s do Conselho Standards Standaarden Normes Normen Standard Est ndares Normas Producer Name Naam fabrikant Nom du producteur Name des Herstellers Nome del produttore Nombre del fabricante Nome do fabricante Producer Address Adres fabrikant Adresse du producteur Anschrift des Herstellers Indirizzo del produttore Direcci n del fabricante Endere o do fabricante Gas Fryers GL 165 P GL165 N GL166 P GL166 N GAS APPLIANCE DIRECTIVE 2009 142 EC BS EN 203 1 2005 A1 2008 BS EN 203 2 4 2005 Thor Fourth Way Avonmouth Bristol BS11 8TB United Kingdom I the undersigned hereby declare that the equipment specified above conforms to
5. KEE ne 10 Operation Guide Filling the Fryer Pot Shutdown Procedure Relighting Automatic Pilot Valve High Limit Control Cleaning and Maintenance RER REE RK ERR ERKEEK KREE RRE E KEE RK ERR ERR KEE KEE KREE EE KEE K KK EK EN 13 Routine Maintenance Daily Cleaning Weekly Cleaning Service amp Adjustments mmmssmmenmennennnnennnnnnnnnenennenennennennnnnnnnnennennnnnnnn 15 Trouble shooting smemmennnnnnennennennennenmnennnnnemnnmennennennnnnnnnmnnennnnnnnnnne 16 Wiring Diagram TTT 16 Explosion DraWing ss mmnnssmssmnnnnnnennennnnnnnnenmnnnnnnmnenmennennnnnnnnnnnnnnnnnnnn 17 Spare Parts List uses assscasensennmmecsnsnmmnsataemnaman a nsnssmemmn a ninnssnmnnss 18 Thor Fryer Manual 12082014 Page 2 Introduction We are confident that you will be delighted with your Thor Gas Fryer and it will become a most valued appliance in your commercial kitchen To ensure you receive the utmost benefit from your new Gas Fryer there are two important things you can do Firstly Please read the instruction book carefully and follow the directions given Secondly If you are unsure of any aspect of the installation instructions or performance of your appliance contact your dealer promptly In many cases a phone call could answer your question CE Only These instructions are only valid if the country code appears on the appliance If the code does not appear on the appliance refer to the supplier of this appliance to o
6. STMENTS PROTECTED E G PAINT SEALED BY THE MANUFACTURER SHOULD NOT BE ADJUSTED BY THE USER OPERATOR Open the burner compartment door and do the following 1 Turn thermostat to 0 before lighting the pilot 2 Press down the ka ignition button and hold down Shut down Button Piezo Ignitor Pilot Position 3 While pressing the ignition button down use a lit match or piezo ignitor to ignite the pilot Continue to press the knob down for about 30 seconds If the pilot does not stay lit when the ignition button is released repeat the lighting procedure and keep the ignition button down longer Adjustment of pilot flame may be necessary 4 When the pilot stays lit turn the knob counter clockwise to the temperature required Do not press down on the knob in this step 5 Do NOT turn the thermostat on until the fryer pot is filled with oil or solid shortening 6 Once the fryer pot is filled with oil set the thermostat to the desired temperature Filling the fryer pot 1 Close drain valve completely before filling the fryer pot 2 When the fryer is new fill the fryer pot with water and clean thoroughly see Weekly Cleaning on page 14 in order to remove protective coatings and any foreign matter 3 The recommended solid shortening capacity for the fryer pot 35lbs 16kgs 45lbs 20kgs 55lbs 25kgs is described on the serial plate which is located inside the front door 4 Remove the basket support frame when filling t
7. Specifications General Stainless steel enclosure All burners have flame safeguard The valve is the modulating thermostat with on off function with temperature selecting knob Cast iron burner Thermostat with manual reset limit switch Three four burner Three four combustion tube Oil Tank size14 14 Pack Contents The following is included o Gas Fryer Castors Instruction Fryer Restraint Chain Gas Supply Requirements Natural Gas G20 Propane G31 Butane G30 GL165 N GLi66 N GL165 P GL166 P GL165 P GL166 P Single burner Heat Input 8 8 KW 8 8 KW 8 8 KW 8 8 KW 8 8 KW 8 8 KW Heat Total 26 4KW 35 2 KW 26 4KW 26 4KW 35 2 KW 26 4KW Burner Operating 17 mbar 14 mbar 36 mbar 34 mbar 27 29 mbar 20 mbar 37 mbar 28 30 mbar Supply Pressure 34 BSP Male 34 BSP Male 34 BSP Male Gas Connection The burner operating pressure is to be measured at the gas control valve outlet test point with one burner operating at High setting The operating pressure is ex factory set through the appliance regulator and not to be adjusted Thor Fryer Manual 12082014 Dimensions GL165 P GL165 N GL166 P GL166 N Thor Fryer Manual 12082014 Page 5 Installation Installation Requirements NOTE It is most important that this appliance is installed correctly and that operation is correct before use Installation shall comply with local gas health and safety requiremen
8. Thor Gas Fryer CE a Installation and Operation Instructions PIN 359001374 BS EN203 1 2014 Gas heated catering equipment TYPE A Model GL165 P GL165 N GL166 P GL166 N IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment For Warranty Service and or parts this information is required Model Number Serial Number Date Purchased WARNING For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliances Keep the area free and clear of combustible materials WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Instructions must be posted in a prominent location All safety precautions must be taken in the event the user smells gas Safety information can be obtained from your local gas supplier thor Fourth Way Avonmouth Bristol BS11 8TB Contents IntrOQUCTION ccoo ina 3 Specifications iii a lia ca 4 General Pack Contents Gas Supply Requirements DIMENSIONS siii 5 Installation gege Eet d ENN Ee ee idee Raai 6 Installation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning Operation enee EN EEN EEN EE EEN NEEN NEEN E EE ENEE ENEE EN ENN ENEE ENEE
9. btain the technical instructions for adapting the appliance to the conditions for use in that country WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED INTHE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION CAUTION THIS APPLIANCE IS FOR PROFESSIONAL USE AND IS TO BE USED BY QUALIFIED PERSONS ONLY ONLY QUALIFIED SERVICE PERSONS ARE TO CARRY OUT INSTALLATION SERVICING AND GAS CONVERSION OPERATIONS COMPONENTS HAVING ADJUSTMENTS PROTECTED BY THE MANUFACTURER SHOULD NOT BE ADJUSTED BY THE USER OPERATOR DO NOT OPERATE THE APPLIANCE WITHOUT THE CASTORS SUPPLIED FITTED Thor Fryer Manual 12082014 Page 3
10. e ignition problems abnormal burner flame burner control problems partial or full loss of burner flame in normal operation be noticed the appliance requires IMMEDIATE service by a qualified service person and should not be used until such service is carried out Thor Fryer Manual 12082014 Page 12 Cleaning and Maintenance Thor equipment is constructed with the best quality materials and is designed to provide durable service when properly maintained To expect the best performance your equipment must be maintained in good condition and cleaned daily Naturally the frequency and extent of cleaning depends on the amount and degree of us age Following daily and more extensive periodic maintenance procedures will increase the life of your equipment Climatic conditions e g salt air may result in the need for more thorough hand more frequent cleaning in order to keep equipment performing at optimal levels If necessary to move the fryer for cleaning etc drain oil first to avoid death or serious injury If disconnection of the restraint is necessary to move the appliance for cleaning etc reconnect it when the appliance is moved to it originally installed position DAILY CLEANING Turn thermostat knob to 0 position Place hot oil safe container under the drain and drain the fryer pot completely Remove the basket support frame if applicable and flush out any sediment remaining in the fryer pot with a lit
11. he fryer pot with solid shortening Thor Fryer Manual 12082014 Page 10 Operation 5 When solid shortening is used be careful not to bend break or twist the thin capillary wires of the elements located in the fryer pot 6 Pack solid shortening into the zone below the tubes all spaces between the tubes and at least an inch above the top of the tubes before lighting the fryer If any air spaces are left around the heat tube surfaces when the heat is turned on the tube surfaces will become red hot burn the solid shortening weaken the fryer pot and could result in a fire AN CAUTION NEVER ATTEMPT TO MELT A SOLID BLOCK OF SHORTENING ON TOP OF THE HEAT TUBES NEVER START THE BURNERS WHEN THE FRY POT IS EMPTY 7 To prevent burning or scorching the solid shortening keep the thermostat set at the lowest temperature until all the solid shortening between and above the tubes has been melted Additional solid shortening can then be added until the desired frying depth has been reached 8 Replace the basket support frame over the fryer pot heat tubes Shutdown Procedure Standby Turn thermostat on the combination gas valve to the O position At this setting only the pilot burner will remain ignited Complete Shutdown Press the shut down button to extinguish pilot burner and main burner and turn thermostat completely off Relighting In the event of a main burner ignition failure a five minute purge period must be
12. is assembled before delivery except castors e This appliance is fitted with adjustable castors to enable the appliance to be positioned securely and level This should be carried out on completion of the gas connection Refer to the Gas Connection section e When a fryer is installed on castors the fryer restraint chain must be attached to the back of the unit and adjacent wall Thor Fryer Manual 12082014 Page 7 Gas Connection NOTE ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON A 3 4 male BSP line for the gas connection is located near the lower right rear corner of the fryer The serial plate located inside the front door of the fryer indicates the type of gas the unit is equipped to burn natural gas or propane The fryer should be connected ONLY to the type of gas for which it is equipped If applicable the vent line from the gas appliance pressure regulator shall be installed to the outdoors in accordance with local codes or in the absence of local codes with the Australia AS 5601 AG 601 to be AS 5601 Gas Installations or New Zealand NZS 5261 Gas Installation An adequate gas supply is imperative Undersized or low pressure lines will restrict the volume of gas necessary for satisfactory performance A combination gas valve and pressure regulator which is provided with each unit is set to maintain a 1 0kPa manifold pressure for natural gas or 2 75kPa manifold pressure for propane gas Fluctua
13. nless steel and are not harmful Heat tint can normally be removed by the above cleaning techniques but tint which does not respond to that procedure calls for a vigorous scouring in the direction of the polish lines using SCOTCH BRITE scouring pads or a STAINLESS scouring pad in combination with a powered cleanser Heat tint action may be lessened by not applying or by reducing heat to equipment during slack periods Thor Fryer Manual 12082014 Page 14 Service For Authorized Service Technician Only NOTICE Service work is performed by other than a qualified technician OR Other than approved Thor replacement parts are installed N WARNING Adjustments and service work may be performed only by a qualified technician who is experienced in and knowledgeable with the operation of commercial gas cooking equipment However to assure your confidence contact your Thor Service Representative for reliable service dependable advice or other assistance and for genuine factory parts All units are adjusted at the factory In case of problems in operation at initial installation check type of gas and manifold pressure and compare with information listed on the serial plate A mill voltage circuit diagram is located inside the front door of the fryer and also on page 18 CHECKING AND ADJUSTING MAIN BURNERS The main burners should burn with a steady blue flame and the inner cone of the flame from each port should be abou
14. observed prior to re establishing the ignition source 1 Shut off all gas 2 Wait five minutes 3 Follow the Lighting procedure described on pageli Automatic Pilot Valve The Automatic Pilot Valve provides an automatic safety shut off or the fryer when the pilot flame is extinguished When the pilot flame is burning the valve is held open electromagnetically by the electrical current from a thermopile in the pilot flame When the pilot flame goes out generation of current ceases and the valve closes automatically Thor Fryer Manual 12082014 Page 11 Operation High Limit Control Thor Fryers are equipped with a secondary heat control that prevents the oil temperature from rising above 195 C 450 F Because of the accuracy tolerance of the sensor the oil temperature may reach as high as 200 C 475 F In the event the fryer shuts down due to this condition the oil must be cooled to below185 C 400 F before the pilot burner can be re ignited When the oil has cooled use the Lighting procedure on page 11 to place the fryer back in operation If the problem persists contact our Thor Service Representative or the Thor Service Department Main burner air supply 1 For efficient burner operation a proper balance of gas volume and primary air supply must be maintained which will result in complete combustion Insufficient air supply results in a yellow streaming flame Primary air supply is controlled by an air shut
15. of the unit After connecting the gas supply check again that the fryer is level Use along spirit level four ways across the front and rear of the fryer pot and along each edge Commissioning 1 Before leaving the new installation a Check the following functions in accordance with the operating instructions specified in the Operation section of this manual e Light the Pilot Burner e Light the Main Burner e Turning OT the Main Burner Pilot b Ensure that the operator has been instructed in the areas of correct lighting operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and a record of the Date of Purchase Date of Installation and the Serial Number of the Appliance must be recorded and kept with this manual These details can be found on the Rating label refer to the Gas Connection section NOTE If for some reason it is not possible to get the appliance to operate correctly shut off the gas supply and contact the supplier of this appliance Install the Regulator Propane Applications Proper Regulator Must Be Installed E Regulator Thor Fryer Manual 12082014 Page 9 Operation Operation Guide CAUTION e THIS APPLIANCE IS FOR PROFESSIONAL USE AND IS ONLY TO BE USED BY QUALIFIED PEOPLE e ONLY QUALIFIED SERVICE PERSONS ARE TO CARRY OUT INSTALLATION SERVICING OR GAS CONVERSION OPERATIONS e COMPONENTS HAVING ADJU
16. ports are unobstructed CLEANING STAINLESS STEEL SURFACES To remove normal dirt grease and product residue from stainless steel use ordinary soap and Water with or without detergent applied with a sponge or cloth Dry thoroughly with a clean cloth Never use vinegar or any corrosive cleaner To remove grease and food splatter or condensed vapors that have baked on the equipment apply cleanser to a damp cloth or sponge and rub cleanser on the metal in the direction of the polishing lines on the metal Rubbing cleanser as gently as possible in the direction of the polished lines will not mar the finish of the stainless steel NEVER RUB WITH A CIRCULAR MOTION Soil and burnt deposits that do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of the finish NEVER USE A WIRE BRUSH STEEL SCOURING PADS EXCEPT STAINLESS SCRAPER FILE OR OTHER STEEL TOOLS Surfaces that are marred collect dirt more rapidly and become more difficult to clean Marring also increases the possibility of corrosive attack Refinishing may then be required Darkened areas called heat tint some times appear on stainless steel surfaces where the area has been subjected to excessive heat These darkened areas are caused by thickening of the protective surface of the stai
17. t 19mm long The flame from each main burner should enter each heat tube without touching the front of the fryer pot or the sides top or bottom of each tube YellowTips ee little air or Blowing or Lifting Flames Normal Flame 00 much gas too much air Thor Fryer Manual 12082014 Page 15 Trouble shooting Pilot won t light Pilot goes out when gas control knob released Main burner will not light No gas supply Releasing knob before the thermocouple has heated Pilot flame too small Gas pressure too low Partially blocked pilot injector Thermocouple connection to the gas control is loose or faulty Thermocouple faulty Electromagnet in the rear of the gas control unit is faulty Incorrect supply pressure Faulty gas control Ensure gas isolation valve is turned on and that bottles are not empty Call the service provider Hold knob in for at least 20 seconds following ignition of the pilot Clean or replace the pilot injector Tighten the thermocouple connection Check that the thermocouple is producing between 20 30mV Inspect and replace if not in good working order Call the service provider Call the service provider Call the service provider NOTE Vibration shock caused by shaking or pounding baskets on top surface or by slamming door may cause Hi Limit Control Switch to open If this condition persists additional cushioning may be added to the rubber grommets
18. ter on the front of the burner 2 Loosen the screws on the front of the burner and adjust the air shutter to just eliminate the yellow tips of the burner flame Lock the air shutter in place by tightening the screws CAUTION The space between the castors at the bottom admits combustion air DO NOT BLOCK THIS SPACE All burners are lit from constantly burning pilots Turning the valve to the desired flame height is all that is required to put the unit in service Do not permit fans to blow directly at the unit Wherever possible avoid open windows next to the units sides or back Avoid wall type fans which create air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a subnormal atmospheric pressure will occur affecting operation and causing undesirable working conditions A properly designed and installed hood will act as the heart of the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions All valves must be checked and lubricated periodically This must be done by an authorized service representative in your area Note Please wait at least 15 seconds to restart the main burners to maintain the best function of the thermostat valve after turning off the main burners IMPORTANT Should any abnormal operation lik
19. tions of more than 25 on natural gas or10 on propane gas will create problems and affect burner operating characteristics Purge the supply line to clean out dust dirt or other foreign matter before connecting the line to the unit It is recommended that an individual manual shutoff valve be installed in the gas Supply line to the unit Use pipe joint compound that is suitable for use with both natural and LP gas on all threaded connections ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS USE GAS LEAK DETECTION FLUID FOR TESTING ON ALL GASES NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE UNIT HAS BEEN PUT INTO OPERATION TEST PRESSURE SHOULD NOT EXCEED 3 45kPa Thor Fryer Manual 12082014 Page 8 Installation N CAUTION THIS APPLIANCE AND ITS INDIVIDUAL COMBINATION GAS VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF 14 WC 1 2 PSIG or 3 45kPa If the incoming gas pressure is in excess of 14 WC 1 2PSI 3 45kPa a proper step down regulator will be required Connect the gas supply directly to the 3 4 male BSP connector located near the lower left rear corner of the fryer When tightening the supply pipe be sure to hold the mating connector extending from the unit securely with a wrench This will prevent any damage or distortion to the internal piping and controls
20. tle hot oil Wipe off the basket support frame and the inside of the fryer pot with a clean cloth A CAUTION SOME AREAS OF THE FRYPOT MAY BE HOT 5 oO N ONO Close drain valve and strain the oil back into the fryer pot through several thicknesses of cheese cloth or filter it back using a filter machine Replace the basket support frame if applicable Add oil or shortening to MIN oil level mark on rear of fryer pot To resume cooking turn the thermostat on WEEKLY CLEANING Follow steps 1 through 4 of the Daily Cleaning procedure see previous section Close drain valve and fill fryer pot with a solution of warm water and boil out compound Relight the fryer and bring the solution to a gentle boil for at least five minutes Turn off main burners and let the solution stand until the gum deposits are softened and the carbon spots and burned grease spots can be rubbed off Scrub the fryer pot walls and heat tubes then drain out fryer pot and rinse it with clean water Refill the fryer pot with clean water and boil again Turn off gas and drain and rinse well until clean Wipe dry with a clean cloth Refill as specified in the Filling the Fryer pot section Thor Fryer Manual 12082014 Page 13 Cleaning and Maintenance MONTHLY CLEANING 1 Perform the Weekly Cleaning procedure see previous section 2 Clean around burner and orifices if lint has accumulated 3 Visually check that burner carry over
21. ts eThis appliance shall be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to health Our Gas Fryers are designed to provide years of satisfactory service and correct installation is essential to achieve the best performance efficiency and trouble free operation This appliance must be installed in accordance with National installation codes and in addition in accordance with relevant National Local codes covering gas and fire safety Australia AS 5601 AG 601 to be AS 5601 Gas Installations New Zealand NZS 5261 Gas Installation United Kingdom Gas Safety Installation and Use Regulations 1998 BS 6173 Installation of Catering Appliances BS 5440 1 amp 2 Installation Flueing amp Ventilation Ireland IS 820 Non Domestic Gas Installations Installations must be carried out by qualified persons only Failure to install equipment to the relevant codes and manufacturer s specifications shown in this section will void the warranty Components having adjustments protected by the manufacturer are only to be adjusted by an authorized service agent They are not to be adjusted by the installation person Unpacking e Remove all packaging and transit protection from the appliance including all protective plastic coating from the exterior stainless steel panels e Check equipment and parts for damage Report any damage immediately to the carrier and distributor