STAR 100R SW Manual(English)
Contents
1. 2 15 Device Setup 2 15 1 Communication Port Setup Setup Set ComPart Chrl h SetlO TECE STARIOOR Ctrl T Read Setting Value Ctrl Setup Set ComPart Ctrl h Set ID TECK STARIOOR Ctrl T Read Setting Walue Ctrl Crrl 0 Ctrl 0 Option Option 15 x Communication Setup Communication Setup Port No i Baud 9600 Interval of Checking 30 min Save Exit Figure 2 35 The communication port number currently connected to the STARIOOR is entered into Port No field Fig 2 35 and COM port status check interval period is entered into Interval of Checking field It is necessary to specify the time interval between PC to STAR1O0OR communication check because there is no continuous data exchange between the PC and STARIOOR The STARIOOR sends an output to the PC only when an event occurs For security purposes it is necessary to cause the PC to check the STAR100R hardware from time to time to ensure the data link integrity 2 15 2 STAR100R Communication Setup Same as 1 4 Communication Setup thru 1 11 Setting Other Outputs 2 15 3 To Read Device Setting Data from STAR100R Setup T Set ComPart Ctrl F ey Setup Set ComPort Ctrl M Set ID TECK STARITOOR Ctrl T viota ola SODC1000 B Fri Option Ctrl O Option Ctrl 0 Same as 1 8 Setting Output for Card or PIN either registered or unregistered thru 1 11 Settin
2. Clicking Person Search button in Fig 2 21 will bring up a search dialogue box Fig 2 22 J ID TECK STAR100R Application Software Insert Name or Card Number or Employee Ref or OK Passwor Lok Cancel m Figure 2 22 In above dialogue box Fig 2 22 the name card number PIN or employee reference number is entered Click on the name s of employee s This will bring up the list below Fig 2 23 when multiple employees are processed clicking one of the individual personnel data will bring up the dialogue box Fig 2 21 Person List Ea Company Department ae N ame Employee Ref Card Number Pasword 4 ABC DEPI PERSON 1 123456 12345678 ABC DEP1 ai Kim 12345 Fig 2 23 There is also an easy way to search by date Enter the date and click Search button A detailed log will be displayed as in Fig 2 21 1 To modify event logger records To modify event logger data if it is necessary double click on the appropriate item A field will be displayed and changes can be made Date InTime Out Time Work Cryer Time Early Le ave Late Status 03 09 2001 E Business Trip Figure 2 24 Next enter new time data in HHMM format Press the Enter button on the PC s keyboard to complete the procedure 2 To modify event logger status Double click the Status in Fig 2 21 This will bring up next screen Fig 2 25 Date Den Time Work Over i Early Leave Late S
3. ID TECK STAR100R Application Software ID TECK STARIOOR Application Software Version 4 02 00 Deleted J USER S MANUAL ID TECK STAR100R Application Software Table of Contents Program Installation 4 1 Using ID TECK STAR100R Application Software T 1 1 Log in procedure 7 1 2 Main Screen 1 1 3 Activating Program 8 1 4 Communication Port Setup 9 1 5 Selecting STAR100R Unit Mode of Operation 10 1 6 Assigning Configuration Card number or PIN 11 1 7 Configuration STARIOOR Input and Output Behaviors 11 1 8 Setting Output Responses Characteristics to Card or PIN 12 1 9 Setting Output for Auxiliary Input Devices 14 1 0 Output Setting for Door Contact and Reed Relay 16 1 11 Setting Other Outputs 18 2 Using the Program 20 2 1 Register Company Information 20 2 2 Register Departmental Information 20 2 3 Title and Position Information 21 2 4 Holiday Data Registration 21 2 5 Hours of Operation Registration 22 2 6 Registration of Authorized Personnel for Entry and Exit 22 2 7 Batch Download 24 2 8 Password and Authority levels 25 2 9 Copying Registered Card Number PIN from STAR100R hardware 26 2 10 Data Back Up and Data Restoration 21 2 11 To pause program operation 29 2 12 Time Event Logger Viewing 30 2 12 1 Desk Schedule in case of employee leave or absence 30 2 12 2 Viewing Individual Event Logger Records 31 2 12 3 Viewing All Event Logger Records 33 2 13 Viewing Entry and Exit Event History 34 2 13 1 Viewing entire event h
4. Software 3 Reminders 3 1 Communication STAR1OOR sends event and alarm input to the PC as a data file But when the PC program is not operating STAR1OOR data output cannot be sent or stored in the PC 3 2 PIN protocol Currently STARIOOR is configured to accept 4 to 6 digit PIN 3 3 Viewing Time Event Logger Records The STARIOOR application software assumes that when viewing time event logger record both entry and exit are made during the same day meaning that the earlier time is regarded as work start time and the later time entry is regarded as quitting time or stop time _4
5. message is activated 99 seconds is the maximum setting P Select Mode nelect Mode Reyer Msecure mode Decides in an event of receiving input signal from Door Contact whether to send output all the time or only when STARIOOR is set to the Secure Mode 17 ID TECK STAR100R Application Software gt Alarm Port Relaye Alarm Time 3 sec TTL Output Time sec Decides where to send output signal when an input from Door Contact is received over a preset length of time Also decides how long in seconds output will be sent 99 seconds is the maximum setting Reed Relay Decides where to send output and for how long in seconds when a magnetic object approaches to STARIOOR gt Mode Select Mode All the tite Relaydisvemm MYsecure mode In an event of a magnetic object approaching STARIOOR this step decides whether to transmit output all the time or to transmit only when STARIOOR is at Secure Mode gt Alarm Port Relave Alartn Time J sec TTL Output Time sec Decides which Alarm Port to send output signal when a magnetic object approaches STARIOOR Also decides for how long in seconds output will be sent 99 seconds is the maximum setting 18 ID TECK STAR100R Application Software 1 11 Setting Other Outputs x Output Setting Max 99 sec Bell Output Set input keypress tirme out Min 10 sec Enable Disable Chime Bell or Door 63 sec Set de
6. screen highlighted in red box shows the number of Card PIN numbers currently registered in the STAR100R hardware You can leave the code field blank for the option Registration of Authorized Personnel The registration of authorized personnel is done by entering their names in the appropriate fields and then by clicking Add button However this alone does not transmit the data to the STARIOOR Click Data Trans button for data transmission from the PC to the STARIOOR hardware Data Transmission Figure 2 9 Authorized Personnel Data Search Click Search button in Fig 2 8 A search prompt screen will appear as in Fig 2 10 24 ID TECK STAR100R Application Software Search x Insert Name or Card Number or Employee Ref or ae Password OK Cancel Figure 2 10 Enter the name of person or his her card number PIN or employee number then click OK button If more than one person share the same data their names and matching information will be displayed as Fig 2 11 Person List zz x Company Department Title Name Employee Ref Card Number Pasword ABC o ey a POS1 PERSON 1 123456 123457 ABC TEST1 POS1 PERSON 1 7894523 123458 Figure 2 11 If the name of person being sought is clicked in Fig 2 11 a display will show data entered in Fig 2 8 Modifying authorized personnel list Modify personnel data then click Modify button Deleting personnel data Se
7. sec Relay Alarm Time l sec TTL Output Time 0 sec Decides where to send output when an input signal is received from auxiliary devices connected to STARIOOR If Alarm Port has been selected you enter how long in seconds output signal should be sent to a selected alarm port 99 seconds is the maximum setting 16 ID TECK STAR100R Application Software 1 10 Output Setting for Door Contact and Reed Relay 1 0 Setup2 Part 2 Door Contact 3 Contact Set Contact Low gt High Register type and time output in Door Open Time out fo i case of intentional openning Select Mode fan the time 4 Reed Relay Relay2 Alarm Time 3 sec Register Motorola FlexPass SDC 1000 type and time output in TTL Output Time 0 sec case of approaching Magnetic Reed Relay Select Mode Al the time Relay2 Alarm Time 3 sec TTL Output Time 0 sec Cancel Fig 1 14 Door Contact indicates if a door is open or closed This I O set up step determines where to send output signal and for how long when an input is received from Door Contact gt Set Contact Input Level Set Contact settings operates as follows Low gt High Door Contact is made when contacts change from Low to High High gt Low Door Contact is made when contacts changes from High to Low gt Door Open Time out Sets how long in seconds a door should remain in open state before door contact error
8. LOCK OFF function is on DOOR LOCK doesn t work in door open status Upon completion of above set up procedures click Finish button and a following message will appear Fig 1 17 Data Transmission Figure 1 17 When the system completes the task of downloading setting values to STARIOOR a message indicating program initialization will appear Fig 1 18 Program Initializing Figure 1 18 20 ID TECK STAR100R Application Software 2 Using the Program Data Management Data Search Event Setup v2 Basi ar ae Hours of Operation cN User User Registration CrleR 2 1 Register Company Information Code Company Add Edit Delete Code Company 01 ABC Figure 2 1 Registration Enter your company s code in Code field Enter your company s name in Company field Click Add Edit button You can leave the code field blank for the option Editing Edit company name by clicking the entry to be changed Make changes then click Add Edit button Deletion Select entry to be deleted by selecting a company in the yellow box Click Delete Button oe ID TECK STAR100R Application Software 2 2 Register Departmental Information e Data Registration Se ae Code Department ae Add Edit Delete Code Department 01 TEST Figure 2 2 Registration editing and deletion procedures are the same as above Company Registration You ca
9. TECK STAR100R Application Software ae 1 1 Log in procedure Login Name Figure 1 1 Defaulted Login name is admin and defaulted password is 123456 1 2 Main Screen Era I 1 3 Activating Program D TECK STARI00R ID TECK STAR100R 128 Data Management DataSearch Event Setup FED Basi S 2 Basic Data i User Registration gt Entrance Y And Exit 3 Event Se Logger wr Ras Event Alarm _ Batch Download iS setup v4 Quick Mode A lication Software Login Name admin Login Time 06 04 2001 22 04 06 Quick Mode button shown in Fig 1 2 appears when STARIOOR is on PIN Only Mode and Card Only Mode Red font indicates that Quick Mode is ON and white font indicates OFF status Exiting while the Quick Mode is on and restarting the program will reset the setting to OFF status The bottom of screen in Fig 1 2 shows user name and log in time This information will be stored in the program folder with a file name including 8 digit MMDDYYYY that reads like HISTORY 11272001 dat This file will record if Quick Mode was turned on or off Screen will show a Please Wait message Fig 1 3 while the system is comparing the latest configuration setup performed via the Application Software to the current configuration stored in the unit Please wait ID TECK STAR100R Application Software If
10. ck NO RF Card PIN information stored in the PC will remain except entry exit data 1 6 Assigning Configuration Card number or PIN fae IO TECK STAR IOON Configuration Card Bs ID TECK STAN IOON Configuration Cand Figure 1 8 1 Figure 1 8 2 Notes 1 If operating mode is RF Card Only then enter Configuration Card number only Fig 1 8 1 2 If operating mode is RF Card PIN number then enter 8 digit Configuration Card number Fig 1 8 1 3 If using PIN only mode then only Configuration PIN number is required for this operation Possible to enter 4 6 digits PIN number Fig 1 8 2 1 7 Configuring STAR100R Input and Output Behaviors 1 0 Setup Figure 1 9 12 ID TECK STAR100R Application Software If Default is selected all I O registration values will be reset to defaulted values Customization of Input and Output responses can be made by selecting the Customs option If Default is selected and Finish button is clicked a dialogue box Fig 1 10 will appear Figure 1 10 If Customs is selected and Next button is clicked a different message Fig 1 11 will appear This is to indicate that current input and output settings stored in the STARIOOR unit is being read However default data will be read and will be displayed as the references Figure 1 11 1 8 Setting Output Responses Characteristics to Card or PIN Output Responses Figure 1 12 Output responses whe
11. d enter how long in seconds the output will be sent 99 seconds is the maximum setting 14 ID TECK STAR100R Application Software Output responses when an unregistered card or PIN is read gt Select Mode Secure mode Determines whether to send output all the time or only when STARIOOR is set to the Secure Mode gt Select Output Port and Activation Time Select the output port when an unregistered card is read or unregistered PIN is entered Zero sec Means no operation Select the activation time from 0 to 99 seconds 1 9 Setting Output for Auxiliary Input Devices 1 0 Setup Figure 1 13 15 ID TECK STAR100R Application Software Up to three 3 auxiliary input devices can be connected to STARIOOR Fig 1 13 shows to where and how long an output will be sent when input signal is generated by auxiliary devices gt Set activating logic for Input 1 Input 2 Input 3 ow gt High Set Input Level JIE Low gt High select Mode Hish gt Lov Select Low gt High if input signal is generated when input device terminal goes from Low to High Conversely select High gt Low if input device terminal generates signal when going from High to Low gt Mode Select Mode All the titne Secure mode Decides whether to transmit output all the time or only when STARIOOR has been set to Secure Mode Relayl Door O gt Alarm Port Relay l Door Open 0
12. ds is the maximum setting Register 2 digit Duress Alarm Password Duress No Duress Number is a 2 digit code except 77 which can t be used that can be entered before card number or PIN can be entered Use of duress code generates alarm 19 ID TECK STAR100R Application Software Alarm time when Duress Alarm detected Duress TTL Output Time Duress TTL OutputTime determines for how long in seconds TTL output will be activated when Duress Code is entered 99 seconds is the maximum setting Enable Disable Chime Bell or Door Bell output Chime Set Enable the use of the ESC key on the keypad to activate the Chime Bell output Chime Bell activating time Chime Delay Chime Delay determines for how long in seconds chime bell will be activated Enable Disable Melody sound Sound Set Sound Set determines whether or not feedback melody will be activated to Card or PIN or command Enable Disable Tamper Alarm Tamper Set Tamper Set determines if an alarm will be activated when STARIOOR is forcibly disassembled from its wall mounted or of the enclosures Set Tamper Alarm Output Port Alarm Port Alarm Port determines the output port for Tamper Alarm Door Status Setting about registered card pin After setting up door staus control if the registered person opens the door by card or PIN number door open status keeps on until next registered person close the door Lock off After door contact check When
13. e the Quick Mode button will appear The red font indicates that Quick Mode is ON and white font indicates an OFF status Clicking Quick Mode button turn on or off Quick Mode status Jfa user other than the System Administrator logs in a prompt dialogue box appears Fig 2 50 gt Quick Mode Login User Name Password Cancel Fig 2 50 Quick Mode can be turned on or off when Administrator username and password are entered 2 15 6 To view program log in log off history HISTORY03092001 Notepad Iof x Fie Edit Search Help Login Name admin Login 03092001 8 58 30 LogOff 03092001 9 05 45 Login Name admin Login 03092001 9 08 59 LogOff 63692661 9 16 61 Login Name admin Login 63692661 9 12 29 LogOff 63692661 9 18 61 Login Name admin Login 63692661 9 18 66 LogOff 63692661 16 62 53 Login Name admin Login 63692661 16 63 19 LogOff 63692661 16 65 22 Login Name admin Login 63692661 16 69 24 LogOff 636926601 16 69 56 Login Name admin Login 63692661 16 16 41 Fig 2 51 When a user logs in the program records the user name and the time when the user logs in and logs off This data is stored as a database file dat in the folder that contains the program In order to retrieve a file for a given day open HISTORT MMDDYYYY dat file This file also records when STARIOOR Quick Mode was turned on or off 40 ID TECK STAR100R Application
14. e 2 32 Enter dates and time into Period Date fields then click Search button This will bring up the display of exit and entry history for that date and time period 36 ID TECK STAR100R Application Software 2 14 Viewing Event Alarm History Event Setup Event List C EvyentfAlarm Alarm List v PA ae i a a Event List User 2001 03 09 10 56 54 gt DEPI PERSON2 11223344 Registration _ Event Alerm Batch Download Alarm List i Card Number 00 00822575 Unregster Card 2001 03 09 11 00 17 14719700 Unregister Card 2001 03 09 10 59 51 14720162 Unregister Card Login Name admin Login Time 03 09 2001 10 20 03 Figure 2 33 Event List screen above Fig 2 33 shows the list of persons who made exits and entries under normal conditions The Alarm List screen also shows the list of alarms generated under Alarm or abnormal conditions The Card Number PIN of a user other than the System Administrator is shown in Fig 2 34 Event List I ie i a ime Department Card Number Password vie o 2001 03 09 10 56 54 DEF FERSON 11223344 Registr ation gt Entrance Amil Esl EvontfAlarm rem List Alarm List Date Status 2001 03 09 11 00 31 Se o 0022575 Unregister Card 2001 03 05 11 00 17 14719700 Unreg eter Card 2001 03 05 10 59 41 14720162 Unreg eter Card Login Time 03 09 2001 10 20 03 Figure 2 34 AT ID TECK STAR100R Application Software
15. er Password Cirie Data UpLoad Ciri Exit In order to temporarily disable software operation click the Pause in the Data Management menu This will prevent others from using the software while the authorized user is away from the PC Moving the mouse cursor will bring up a password dialogue box Fig 2 16 The software will resume operation when the correct login password is provided F 235 wot d Insert Login Password B OK Figure 2 16 The PC will continue to receive data such as events and alarm data from the STARIOOR while the software pauses If you want to enter automatically screen save mode refer to the option field Refer to command 2 15 4 30 ID TECK STAR100R Application Software 2 12 Event Logger Viewing 2 12 1 Desk Schedule in case of employee leave or absence wat Event Data Search Event Setup we Logge Event Logger Desk Schedule Personal Document Total Document Desk Schedule Cts Personal Document Total Document Entrance and Exit gt tas Event When an employee is unable to directly record event logger data due to leave or absence his her event logger data can be pre entered Clicking Person Search button in Fig 2 17 will bring up a dialogue box Fig 2 18 gt Registration Desk Schedule Information Period Date Company 03 09 2001 03 09 200 il Department Status Title N T
16. g Other Outputs 2 15 4 Alarm Message Output and Alarm Sound Setting 38 ID TECK STAR100R Application Software Setup i Setup Set ComPort Ctrl M k Set ComPort Ctrl M Set Motorola SDC1000 Ctrl T Set Motorola SDC1000 Ctrl T Read Setting Value Ctrl V ap Exit Read Setting Value Ctrl Option CrO Option Ctri 0 This window allows to select alarm user wants to see and sound Alarm message will ne shown under selected alarm occurring alarm will sound every 4 seconds Alarta List Alarm Sound ee JEAN ew Folder Motorola SDC 1000 O Try Error Detect O Door Contact Error o ah OINI Input Detect EN OIN Input Detect CIN Input Detect l5 minutes O Temper W Detect O Duress Detect O Magnatic Detect l O Exit Button nave Exit Fig 2 49 The Alarm setting and alarm sound can be set by choosing the setup option selection Next select the alarm type in Alarm List in Fig 2 49 Select a sound file for the speaker wav file from Alarm Sound by clicking the Search When you select Screen Saver time then the program automatically enter the screen save mode after the time settings Refer to pause command 2 11 2 15 5 To turn on off Quick Mode 1D TECE STAA TIOR VIA ni Event Logger Login Hame admin Legia Time 06 04 2001 22 04 06 Fig 2 49 39 ID TECK STAR100R Application Software If STAR1OOR is set to RF Card Only mode or PIN Only mod
17. ick Next to continue with the Setup program WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law Next gt Cancel a ID TECK STAR100R Application Software Click Next gt button STEP 4 Designate directory folder to store the program When selecting a different location for program folder click Browse button If you are installing the program in the default directory folder click Next gt button STEP5 Choose Folder E cS E gt Program Files E gt Motorola As described in Step 3 clicking Browse button for selecting a different directory folder will bring up a dialogue box shown above Select the desired folder STEP6 5 ID TECK STAR100R Application Software STAR100R ACCESS CONTROL GlobalS Hanwha InstallShield 5 5 Professional Edition Internet Explorer MediaPAC Display Utility Microsoft Visual Studio 6 0 Microsoft Web Publishing Motorola SDC1000 Select a folder in the Program Folder This will provide program icon STEP7 Start Copying Files STEP 8 ST lit TOOR ACCESS CONI ROI STEP9 6 ID TECK STAR100R Application Software After Steps 7 9 click Finish button 1 Using ID
18. in text file Date lv 8 Time v 4 Employ Ref Iv 8 Company E Department E 0 Title E 0 Name Iv 10 Card or Pin number V g Select appropreate simbol to devide each field saved in text file OK Figure 2 15 1 In Fig 2 15 1 select the field to be backed up by clicking on the field Also specify the length of field string If the length of stored field is shorter than the specified field length the blank space will fill the remaining unoccupied field Provide a code to distinguish those fields that will be stored as a text file For importing into common applications like Microsoft Excel a comma can be used for Comma Separated Variables csv format Upon completion of specifying the type and length of fields click the OK button A dialogue box Fig 2 15 2 showing file path will appear when above procedure is successfully completed STARIOOR l x WIOORWEnglisht Test txt G Information Back up Complete Backup Filename CaN Figure 2 15 2 Restore from database file To restore from database file first select Backup in Fig 2 14 then click Search button and select the database file mdb extension that contains desired data finally click the Backup Restore button to complete the procedure 29 ID TECK STAR100R Application Software 2 11 To pause program operation Data Management Data Search Event Basic Data k User Registration Ciri A Log in Login Us
19. istory 34 2 13 2 View individual exit entry event history 35 ID TECK STAR100R Application Software 2 14 Viewing Event Alarm History 36 2 15 Device Setup 37 2 15 1 Communication Port Setup 37 2 15 2 STAR100R Communication Setup 37 2 15 3 To Read Device Setting Data from STAR100R 37 2 15 4 Alarm Message Output and Alarm Sound Setting 38 2 15 5 To turn on off Quick Mode 38 2 15 6 To view program log in log off history 39 3 Reminders 40 ID TECK STAR100R Application Software Program Installation The software operating environments CPU Pentium IT 350MHz or higher Pentium II is recommended RAM 32MB or higher 64MB 128MB is recommended Hard Disk 40MB free space CDROM drive required for Software installation Operating OS Windows 95 98 2000 with MS Access Database STEP 1 Insert ID TECK STAR100R Application Software CD in the CD ROM drive Application Software will be installed automatically and you can see the screen as Step2 STEP 2 a ODBC DAO RDO Template Setup is preparing the InstallShield R Wizard which will guide you through the rest of the setup process Please wait 99 STEP3 Welcome to the STAR100R ACCESS CONTROL Setup program This program will install STAR100R ACCESS CONTROL on your computer It is strongly recommended that you exit all Windows programs before running this Setup program Click Cancel to quit Setup and then close any programs you have running Cl
20. lay time to activate Secure Mode Chime Bell activating time Max 99 min 69 eae 69 Keypad lock out time when Try Out error detected 63 min Enable Disable Melody sound On Register 2 digit Duress Alarm Password Enable Disable Tamper Alarm 69 fott Alarm time when Duress Alarm detected Set Tamper Alarrn Output Port No 69 sec Door status setting about registered card pin Look off after Door Contact Check lott Cancel lt lt Back Figure 1 15 Set input keypress time out Set the length of time in seconds allowed for entering required data or command sequence using the keypad If proper data is not entered within the specified time limit the incompleted data or command sequence will be discarded and the next data or command sequence will be processed 99 seconds is the maximum setting and 10 seconds is the minimum setting Set delay time to activate Secure Mode Alarm Delay Alarm Delay decides when Secure Mode will actually be activated after Secure Mode has been selected This setting is measured in minutes and 99 minutes is the maximum setting Keypad lock out time when Try Out error detected Hold Time Hold Time inhibits the STARIOOR keypad from operation for the specified time when number of attempts to use unregistered card number or PIN exceeds the allowable number of attempts The length of time is in seconds and 99 secon
21. lect appropriate field then click Delete button Personnel Search List of personnel and their data can be displayed by clicking User List 2 7 Batch Download When data stored in the STARIOOR hardware is erased either due to equipment problem or by error data can be restored by batch download from the PC Click Batch Download button in the main screen Figure 2 11 1 2 8 Password and Authority levels D5 ID TECK STAR100R Application Software Log in Login User Name Password Login User Name Explanation Administrator TEST Login User Name Password Login User Name Sa Password Pe Confirm PO Explanation FC This user allows to use and all Add Edit Delete functions in this program EXIT Figure 2 12 There are three 3 levels of authorities Administrator Power User and User A person s ability to access different features of the program is based on his her authority level as defined by the user ID and pass word 1 Administrator Administrator has full access to all program features 2 Power Login User Power login user has access to program features but Cannot use the program to register modify or delete Card number PIN in the STARIOOR _ Cannot copy or download Card number PIN stored in the STARIOOR Cannot assign login user password authority level Cannot restore or back up database 3 Login User User can only view or download exit entr
22. n a registered card or PIN is read gt Door Open Time Bee ID TECK STAR100R Application Software Sets how long in seconds the door connected to STARIOOR will stay open when a registered card is read The maximum setting 1s 99 seconds gt TTL Output Time Sets how long in seconds the TTL output signal will be active when a registered card is read The maximum setting is 99 seconds gt Set Exit Detection Level Set Exit settings operates as follows Low gt High exit requested is detected from Low to High High gt Low exit requested is detected from High to Low gt Set TTL Output Level Low gt High TTL out put changes from Low to High High gt Low TTL output changes from High to Low Output responses when an unregistered card or PIN Try Out is read gt Set number of times for Try Out Try Out alarm is generated when number of attempts to pass an unregistered RF card or to enter unregistered PIN exceeds the allowed number of attempts gt Select Mode Select Mode Relay2 Alarm Time There is no mode selection for Relay2 Alarm Time In an event of Try Out situation this setting determines whether the selected output port is activated in all modes of operation or just in the Secure Mode gt Select output Port and Activation Time RelayeAlartn Time J sec TTL Output Time l sec In an event of Try Out situation determines where to send output If Alarm Port is selecte
23. n leave the code field blank for the option 2 3 Title and Position Information 215 xj Department Data Registration Add Edit Delete Code Duty 4 02 POS Figure 2 3 Registration editing and deletion procedures are the same as above Company Registration You can leave the code field blank for the option 2 4 Holiday Data Registration ef Data Registration Department Holiday Holiday Date Delete Date a 03 07 2001 Figure 2 4 Holiday registration editing and deletion procedures are the same as above Company Registration 37 ID TECK STAR100R Application Software Clicking Date field Fig 2 4 opens a calendar You can choose a date and it will be entered in the Date field You can also make direct input by typing in MMDDYYYY in the Date field You can leave the code field blank for the option am Data Registration Ml x Department Holiday Holiday Date lt March 2001 gt M2 2 27 83 1 2 3 TE 4 5 6 7 8 10 1112 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 3 i 2 36 5 6 OF La 23 Today 03092001 EE Exit Figure 2 5 2 5 Hours of Operation Registration i JD Basi Basic Ns ng Basic Da ours of Operation a Hours of Operatio User Registration Cirle User amp Hours of Operation Registration Compan sages Open Time 0900 ABC gt Clo
24. on in above screen will bring up and display Fig 2 14 g gt DB Backup Restore DB Backup Restore f C Backup C Restore Date File Name ooo OE Search Figure 2 14 Database Backup Click Back Up button 1 In order to backup database corresponding to a given date click in the Date field A calendar Fig 2 15 will be displayed Select a desired date and click gt DB Backup Restore OE xi DB Backup Restore Backup C Restore Backup Restore March 2001 STE Fel Exit Date 25 25 27 123 4 5 6 7 8 10 wm 11 12 13 14 15 16 17 File Nan jg 19 20 21 22 23 24 2 2 27 28 29 30 31 B 1 e a r Search 3 Today 03092001 Figure 2 15 2 To backup database using MS Access To backup the database as a MS Access file mdb file click Search button and select a name for the file with a mdb extension Next Backup Restore button and the file will be saved as an MS Access file 28 ID TECK STAR100R Application Software 3 Text file back up Unlike MS Access files a text file cannot be used for file restoration To backup as a text file click Search button This will bring up the list of files Select the file then click Backup Restore button At this point Text Back up dialogue box Fig 2 15 1 will appear fi Text Backup E i a Select field and length of that which willbe saved
25. play Fig 2 29 will appear Next enter the date time period and select the desired event or alarm event from the Status field Click the Normal to view the history of normal exit entry data Click the Alarm to view the history of alarm events 35 ID TECK STAR100R Application Software 2 13 2 View individual exit entry event history Data Search Event p Entrance Event Logger bd And Exit Total Document Entrance and Exit gt Total Document T F ME eee ersonal Document Personal Document ot Time Entrance and Exit Personnal Document Period Date Date Time a 03 09 200 1 03 09 200 1 Period Time 0o00 2359 Information Company Ey Department i O Tite i O Name Loo Employee Ref fo Card Number OoOo Password Print Data Search Exit xj Figure 2 30 Clicking Person Search in gt 2 30 will bring up a aoe es box below Fig 2 31 Search a x Insert Name or Card Number or Employee Ref or OK Password OK Cancel Figure 2 31 In above dialogue box Fig 2 31 enter the name card number PIN or employee reference number to begin the search This will bring up a display of list shown below Fig 2 32 This list will include all personnel linked to the data provided in the dialogue box 2 Person List ee sepe mE Name Employee Ref Card Number Pasword EIET PERSON 12345 6 12345678 eae ina aE Kim 12345 Figur
26. raining aiiz Business Trip Employee Ref Vacation Leaving earl Card Number Password Search E x Insert Name or Card Number or Employee Ref or Password Cancel Figure 2 18 In above dialogue box Fig 2 18 the name card number PIN or employee reference number is entered This will bring up a list shown below Fig 2 19 It will show multiple names if they are linked to the data just entered Person List Company Department Title Name Employee Ref Card Number Pasword ABC I DEP1 POS PERSON1 1234567 12345678 ABC DEP1 POS Kim 12345 Figure 2 19 diie ID TECK STAR100R Application Software After selecting the name of the person input the range of period for event logger data entry by clicking the Period field in Fig 2 17 Registration Desk Schedule Screen A calendar will appear Fig 2 20 Registration Desk Schedule Peai eoar Sun Mon Tue Wed Thu Fri Sat 27 28 6 7 13 14 20 21 27 28 ae coe Figure 2 20 Next select the dates and click on the calendar This also enters the same dates into the Period Date fields Now click the appropriate duty status in Status fields This will account for the employee s absence from the company facility 2 12 2 Viewing Individual Event Logger Records a Event Logger Time Attendance Personal Document Pije x 1 a a SS TT 03 09 2001 03 09 2001 Business Trip 1234567 12345678 Figure 2 21
27. se Time 1730 Saturday 1230 Figure 2 6 Hours of Operation Registration enable each company to register its operating hours Select a company then enter the open time in Open Time field and the close time in Close Time field Enter the Saturday close time in Saturday Close Time field Click Save button to save work hour settings To edit each company s work hours click on the company to display previously set working hours Make changes as necessary then click Save button 2 6 Registration of Authorized Personnel for Entry and Exit A message Fig 2 7 will appear prior to personnel registration screen During this time the system compares card or PIN numbers stored in STAR1OOR to those stored in the PC Eee ID TECK STAR100R Application Software Please wait Figure 2 7 When above procedure is completed those Card PIN numbers stored only in the STARIOOR hardware will show under the heading Registered in Hardware Only 1 in Fig 2 8 and Card PIN numbers stored only in the PC will show under the heading Registered in Software Only 2 in Fig 2 8 Rregistered in Hardware only Company _CARD NUMBER PIN NUMBER Modify Department aa 1 Title i o De e Name sY Search a Rregistered in Software only SMUG iai _ am CARD NUMBER PIN NUMBER Card Number Mata Trane Password 2 Figure 2 8 The status bar on the top of
28. tatus 2000 11 27 19 25 11 02 Figure 2 25 A change is made by clicking on a different status item 33 ID TECK STAR100R Application Software 2 12 3 Viewing All Event Logger Records Figure 2 26 To view the daily event logger records enter a date and select company in Fig 2 26 Select a department in the Department column then click the Search button Next a list of event logger information will be displayed Fig 2 26 Repeat the process described in 2 11 2 for viewing individual event logger 2 Viewing event logger records during a given period 1230567 PERSONI 3 EHS Kim Figure 2 27 34 ID TECK STAR100R Application Software In Fig 2 27 dates entered in Period Date field will cause the frequency of corresponding events to be displayed To view the detailed event logger record of a person click the Employee Ref or Name field Next a detailed display will be shown as below Fig 2 28 amp Time Attendance Personal Document ile x oe 03 09 2001 03 09 2001 a Absence 12345678 Figure 2 28 2 13 Viewing Entry and Exit Event History 2 13 1 Viewing entire event history Entrance _ And Exit Entrance and Exit gt a Time Entrance and Exit Total Document p x a E a E foo00 2359 Figure 2 29 To view the entrance and exit select the Data Search Entrance and Exit Total Documents the dis
29. the two settings are different you will see a prompt message below Fig 1 4 ID TECK STAR100R Figure 1 4 Select Yes to begin the configuration sequence to establish new settings or operation behaviors of the STARIOOR unit click No to skip the configuration steps 1 4 Communication SetUp Operation ae The first screen Fig 1 5 in the configuration sequence is the selection of the communication port available from the PC for use by the ID TECK STAR100R Application Software and STAR1OOR unit Figure 1 5 Select the appropriate COM port if a COM port other than 1 thru 4 then enter that port ID TECK STAR100R Application Software number in Port No field If communication between the unit and the application software is required during normal usage even after the configuration is completed then monitoring this communication link on a regular interval is highly recommended 10 ID TECK STAR100R Application Software 1 5 Selecting STAR100R Unit Mode of Operation The STARIOOR unit can be set to operate in one of three modes shown below x STAR100R Mode Select ae This Mode allows users to use the RF card only Card Maximum numbers of registered users are 147 possible to enter digit Card number This Mode allows users to use both Card and PINnumber The maximum numbers of registered users are 63 An d digtt Card number registration is available A 4 6 digit PIN number registration is a
30. vailable Card And Pin Number This Mode allows users ta use PIN number only C PIN Number Maximum number of registered users are 127 possible to enter 4 6 digit PIN number This Mode allows users to use both Card or Pl Number The mammum numbers of registered users are 63 An digit Card number registration is available A 46 digit PIN number registration is available c Card Or Pin Number Cancel lt lt Pre Next gt gt Figure 1 6 Card Card Mode RF Card Only This mode requires RF card alone for granting entry and exit privileges Card PIN Card and PIN Mode RF Card PIN This mode requires both RF Card and PIN for entry and exit PIN PIN Mode PIN Only This mode requires PIN alone for entry and exit Card or PIN Card and PIN Mode RF Card or PIN This mode requires RF Card or PIN for entry and exit Note If a change in operating mode is made all Card or PIN data currently stored in the STAR100R unit will be erased and a prompt will appear as shown in fig 1 7 Mode change is done by clicking Finish button in fig 1 9 or 1 15 1D TECK STAR100R x Applied Mode of ID TECK STAR100R wil be changed If so it will delete all information saved in ID TECK STAR100R Continue Yes No ID TECK STAR100R Application Software Figure 1 7 If you also select Delete all information saved in PC all registered database information stored in the PC will be erased If you cli
31. y data personnel data Card number PIN will be displayed as when viewed by login users other than the administrator To register a login user Enter a PC program login user s name and password Confirm the password by repeating the password Enter notes in Explanation field To modify login user information Click the login user information fields shown in Fig 2 12 to be modified Modify login user information and click Add Edit button To delete a login user Click the login user information fields shown in Fig 2 12 to be deleted Delete by clicking Delete button 26 ID TECK STAR100R Application Software 2 9 Copying Registered Card Number PIN from STAR100R hardware Data Management Data Search Event Basic Data I User Registration Ctri A Log in Login User Password Ctrl Card Number Upload screen Fig 2 13 will be displayed when Data Upload is clicked as shown in the red box Card Number UpLoad Address Pin Number 4 1 123457 2 123458 3 123459 4 123479 5 6 7 8 9 10 1i Figure 2 13 Card PIN numbers stored in the STARIOOR will be displayed when Upload button in Fig 2 13 is clicked 57 ID TECK STAR100R Application Software 2 10 Data Back Up and Data Restoration Data Management Data Search Event Basic Data User Registration Ctrl Log in Login User Password Cirle Ctrl Clicking Data Backup Restore butt