Home

Stage pro spot 1000 PC teatro

image

Contents

1. LIGHTING We thank you for choosing the projector STAGE PRO SPOT 650 1000 1200 PC To make the most of this unit and to make it work correctly in the years before connecting it to its source and using it we suggest you to carefully read this manual In this way you will be more familiar with it and its connections and will be easier to use it All the sections of this manual have been studied to make as easy and complete as possible the use of the STAGE PRO SPOT 650 1000 1200 PC To make the manual more clear and easy to consult we have used the following symbols and conventions AN IMPORTANT very important warnings to be read with the maximum attention l important parts of the text that give details and or explanations on the use of the STAGE PRO SPOT 650 1000 1200 PC practical advices for an efficient use of the STAGE PRO SPOT 650 1000 1200 PC YOUR REFERENCE Cite the model and the serial number anytime you contact your retailer to ask for information or assistance STANDARD PACKAGE The standard package of the projector STAGE PRO SPOT 650 1000 1200 PC contains 1 Projector ON REQUEST 2 Mains connector Lamp code 060261 3 User s manual 4 Leaf barndoors code 040102 4 Guarantee Black clamp 50 code 194019 5 Colour frame Spare colour frame code 040099 AN IMPORTANT Make sure that the unit has not been damaged during the transportation In case it has happened or in case the unit does not
2. 1200 PC follow these instructions 1 Periodically clean the in out air grates 2 Periodically clean the lens and the reflecting parabole fig 5 using antistatic cloths and products e Do not absolutely use solvents or abrasive products Rev 12 2005 Working to make its products always more perfect LED reserves the possibility to make technical changes during the production The technical features and the drawings on this manual are not binding for LED and they could be changed at any time without notice LED it is not responsible for any inconven ience caused by an improper or different use of the unit respect to the one for what it has been made
3. to heat sources Never to lean the connecting cable on the hot unit The unit must be at a minimum distance of 30 cm from the walls or from any inflammable material and 1 mt from lighted objects The unit must be placed where it could be easily aerated To avoid obstructing the in out air gratings Do not directly look at the Lamp when it Is on STAGE PRO SPOT 650 1000 1200 PC CODE 991187 Us LIGHTING l Before installing the STAGE PRO SPOT 650 1000 1200 PC make sure that the carrying structure is safe and able to support the weight of the unit The STAGE PRO SPOT 650 1000 1200 PC is equipped with a bracket with a hole in the middle diam 10 mm to fix clamps and or screw bolts fig 1 and 4 To orientate the unit follow these instructions 1 Unscrew the Manual Orientation Knob on the side of the unit fig 1 2 Orientate the unit using the apposite handle at the back fig 4 3 Screw the Manual Orientation Knob e It is possible to turn the bracket up or down At the end of the assembling operations make sure that the unit has been correctly and safely fixed FIXING THE COLOUR FRAME AND THE 4 LEAF BARNDOORS The STAGE PRO SPOT 650 1000 1200 PC is already equipped with the Colour Frame fig 1 and 5 To insert the filter in the Colour Frame follow these instructions 1 Unhook the clamping lever on the left side of the unit fig 1 and 4 2 Take off the Colour Frame and insert the filter 3 Take of
4. AND REPLA CING THE LAMP In case of replacement of the Lamp or maintenance never open the unit IMPORTANT unless are passed at least 15 minutes after it went off 1 Disconnect the unit before replacing the Lamp Always wear protective gloves and goggles 3 4 Fit the new Lamp in its socket not forcing too much fig 5 2 Turn the key at the bottom of the unit for a quarter of turn left to right fig 5 Open the cover fig 4 and 5 Take care of not touching the glass of the new Lamp with the nude hands in case it accidentally happens clean the Lamp bulb with a dry cloth and alcohol 5 Close the cover turning the key for a quarter of turn right to left COLOUR FRAME SR To avoid any bad performance of the unit or the Lamp breakage LAY damaging the optics of the STAGE PRO SPOT 650 1000 1200 PC replace the lamp as soon as its maximum average time ends The lens must be replaced when is evidently damaged and if its efficiency has been reduced for example from slits or deep cuts LAMP REFLECTING PARABOLE KEY TO OPEN THE COVER LAMP ROOM LIGHT BEAM REGULA TION Correct regulation of the light beam e Turn the knob placed on the rear part of the unit fig 4 e Turning the knob from right to left the light beam amplitude is reduced from left to right it is enlarged MAINTENANCE Before operating any maintenance disconnect the mains For operating a correct maintenance of the STAGE PRO SPOT 650 1000
5. f the spring clip insert the filter and put back the spring clip 4 Put back the Colour Frame in its room making it sliding on its track 3 It is recommended to use only filters with an high temperature resistance To fix the 4 Leaf Barndoors on request fig 3 follow these instructions fig 3 1 Unhook the clamping lever on the left side of the unit fig 1 and 4 CODE 040102 2 Insert the 4 Leaf Barndoors in its room making it sliding on its track CONNECTION TO THE POWER SUPPLY SAFETY CHAIN FIXING EYE HANDLE an LED CLAMPING LEVER TO INSERT THE COLOUR FRAME AND THE 4 LEAF BARNDOORS vat a wall 3 YWueight alal Ha THREE POLES FEMALE CONNECTOR POWER SUPPLY INPUT FORTHECONNECTIONTOTHE MAINS LIGHT BEAM MANUAL BRACKET ORIENTATION KNOB COVER PHASE Brown The unit must be connected to the earth The inobservance of N NEUTRAL Blue 3 a l EARTH Green Yellow these instructions automatically makes the guarantee expiring L 7 Before connecting the unit to the mains make sure that the working voltage and frequency correspond to the values indicated on the label fig 4 The STAGE PRO SPOT 650 1000 1200 PC is made to work at a working voltage of 230V 50Hz 2 8 4 3 5 2 A depending LE The unit mains connections are described in fig 4 a LIGHTING STAGE PRO SPOT 650 1000 1200 PC CODE 991187 FITTING
6. work correctly immediately contact the Retailer If the unit has been directly sent to you immediately contact the Freight Company Only the final receiver the person or the Company that receive the unit is in the position to complain for the above inconveniences The safety of the unit is guaranteed only strictly following the instructions so it is recommended to accurately preserve them User s manual product code 991187 TECHNICAL FEATURES fig 1 MANUAL Halogen 650 1000 1200 W GX 9 eee l KNOB BRACKET LAMP With endless screw MOVEMENT VERTICAL 90 45 f MOVEMENT Manual orientation Fig 1 amp LIGHT BEAM Refer to Fig 2 O AMPLITUDE LEVER FOR INSERTING THE COLOUR FRAME AND THE 4 LEAF BARNDOORS e Nominal operating voltage 230 Vac 50 Hz INPUT POWER e Rated power supply 650 1000 1200 W e Nominal current 2 8 4 3 5 2 A 230 Vac WORKING Any position POSITION DIMENSIONS mm 290 x 370 x 400 Fig 1 W xD x H WEIGHT BODY Steel and aluminium Lux 1204 301 76 LUN 7200 1800 45 3 ii ih A A fig 2 LIGHT BEAM AMPLITUDE RELATED TO DISTANCES 13 62 Amplitude Distance in mt Do not dismantle and modify the unit Always make sure that you are using a safety chain fig 4 Do not install the unit outdoors directly exposed to rain or moisture To avoid any inflammable liquids water or metal objects entering the unit To avoid installing the unit close

Download Pdf Manuals

image

Related Search

Related Contents

在宅酸素療法における酸素供給装置の 保守点検業務に関する基準  Barco MDCG-5121  MAN-Win Scale-d - Sartorius Intec  Memorex MVD2113 TV DVD Combo User Manual  A Petits Pas Maternelle Mode d`Emploi juin 2010 VF  Allied Telesis Patch SB244-01 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file