Ingecon Sun Smart TL Installation Manual
Contents
1. The MAIN MENU may be accessed by pressing OK once on the display The main menu contains the following submenus 12 00 12 04 10 12 00 12 04 10 MAIN MENU Arona E Change date Monitoring Start Stop Configuration Reset partial data Language Change inverter number Change date MONITORING This displays the main internal parameters and variables that indicate the operation status of the unit CONFIGURATION Certain firmware parameters can be changed in this menu to adapt it to differ ent operating conditions LANGUAGE The display language can be selected between English and Spanish in this menu CHANGE DATE The inverter time can be adjusted in this menu ON OFF Inverter operation can be started and stopped manually from this menu RESET PARTIALDATA PARTIAL DATA Sets the Sets the partial date for Part E Tp con and Npcon to zero date for Part E Tp con and Npcon to zero a NN NUMBER The inverter is allocated an SEE number within the PV installation from this menu 9 4 Monitoring This is accessed by pressing LOK once the MONITORING menu has been selected The first screen displays a menu for selecting each of the three output phases of the unit with a separate data display for each of them To 12 00 12 04 10 display for example Phase 1 select it and press OK 12 00 12 04 10 MAIN MENU MONITORING Monitoring Language se Phase 3 Change date
2. state otherwise A A A gt y AAY2000IKI03 Rev Date March 2011 The various maintenance tasks must be performed by qualified personnel Danger of electric shock To access the various compartments take the recommendations of the chapter on Safety Instructions into account All the maintenance checks included here must be carried out with the machine stopped under safe conditions for handling including those specified by the client for these types of operation Check status of the enclosure A visual check of the status of the enclosure must be performed verifying the status of locks doors IP65 protection seals and handles and the unit fixings at both lower and if any upper anchorage points In addition the condition of the enclosure must be checked for dents scratches or rust that might degrade the cabinet or cause it to lose its protection classification If this type of defects are noticed the parts affected must be substituted Check the status of cables and terminals Check the correct path of the cables so they do not come into contact with live parts Check the insulation deficiencies and hot spots by checking the colour of the insulation and terminals Tightness of strip fasteners and power cables Check tightness as per following clamping force M8 24 Nm M10 47 Nm M12 64 Nm As per DIN 13 Visually check that the AC feeds comply with safe distances
3. 12 00 12 04 10 Six screens will appear showing the main variables being monitored The right hand screen shows the MONITORING Phase 1 first one Pac 5000 W You can move through them using the and Vac 229 V keys Iac 21 83 A Fac 49 89 Hz PhiCos 0 998 AAY2000IKI03 Page 45 of 64 Rev Date March 2011 Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 Below we can see the structure and interpretation of the variables in this menu Screen 1 Pac Power which inverter is delivering to the grid in W Vac Inverter output voltage V in the electricity grid connection lac Inverter output current A Freq Output current frequency to the electricity grid Hz PhiCos Cosine of Phi Cosine of the phase shift angle between grid voltage and current supplied by the inverter If the phase shift is zero 0 the cosine of phi is 1 cos O 1 Screen 2 Vsolar Voltage supplied by solar panels to the inverter Isolar Current supplied by solar panels to the inverter Screen 3 Alarms Status of inverter alarms The meaning of the alarms is listed below 0000H No alarms 0001H Insufficient input voltage 0002H Grid frequency out of range 0004H Grid voltage out of range 0008H Overcurrent in the inverter bridge 0010H Overcurrent in the DC DC converter 0020H Insulation fault 0040H Grid overcurrent 0080H Overtemperature 0100H Bus overvoltage 0200H Configuration ch
4. Compliance with these standards calls for compliance with limits and procedures in other standards 1 3 2 VDE0126 1 1 disconnection device In countries such as Germany Portugal and France incorporating a device of this type facilitates compliance with the regulations in force for photovoltaic and microgeneration facilities As such our units comply with the standard VDE 0126 1 1 Automatic disconnection for generating installations connected in parallel with the low voltage grid 1 3 3 Regulations for connection to the ENEL Distribuzione grid In Italy to connect to the company ENEL s grid it is necessary to comply with the regulations the company de mands Hence our units comply with the applicable part of standard RTC alle rete BT di Enel Distribuzione Compliance with this standard must be requested on ordering the unit 1 3 4 Engineering Recommendation G83 1 In the United Kingdom there is document G83 1 which recommends the characteristics a microproduction genera tor needs to have Recommendations for the connection of small scale embedded generators in parallel with public low voltage distribution networks Compliance with this standard must be requested on ordering the unit 1 3 5 Compliance with Australian and New Zealand regulations The two standards to be met in Australia are AS NZS 3100 General requirements for electrical equipment AS NZS 4777 Grid connection of energy systems via inverters Comp
5. Date March 20 11 4 4 f pott L Installation Manual INGECON SUN SMART TL AAY20001K103 related documentation CATALOGUES Ingecon Sun a Commercial Catalogue a Spanish PCOOISAO0O English PCOOISA071 Ml Italian PCOOISAO3 German PCOOISA02 French PCOOISA04 and Portuguese PCOOISA05 MANUALS Ingecon Sun LITE Spanish AAY2000IKH01 English AAY2000IKI01 Italian AAY 2000IKRO1 German AAY2000IKQ01 French AAY2000IKV01 and Portuguese AAY2000IKP01 Ingecon Sun SMART Spanish AAS20001KH02 English AAS2000IKI02 Italian AAS2000IKR02 German AAS20001KQ02 and French AAS2000IKV02 Ingecon Sun POWER Spanish AAS2000IKH01 English AAS2000IKI01 Italian AAS2000IKR01 German AAS20001KQ01 and French AAS2000IKV01 Ingecon Sun POWERMAX Spanish AAV2000IKH01 English AAV2000IKI01 Italian AAV2000IKRO1 German AAV2000IKQ01 French AAV2000IKV01 and Czech AAV2000IKZ01 Ingecon Sun SMART TL Spanish AAY20001KH03 English AAY2000IKI03 Italian AAY2000IKRO3 German AAY20001KQ03 and French AAY2000IKV03 AAY2000IKI03 Rev Date March 2011 Ingecon String Control Spanish AAS20021KH01 English AAS2002IKI01 Italian AAS20021KR01 German AAS20021KQ01 and French AAS2002IKV01 Communications accessories Spanish AAX20021KH01 English AAX2002IKI01 Italian AAX20021KRO01 German AASX20021KQ01 and French AAX20021KVO1 Ingeco
6. Pressing OK again confirms the selection AAY2000IKI03 Rev Date March 2011 12 04 10 LANGUAGE SELECTION Espa ol English German Italiano French 12 04 10 LANGUAGE SELECTION ENGLISH Language Continue Confirm OK 12 04 10 MAIN MENU Monitoring Configuration Change date 12 00 09 01 09 CHANGE DATE Save OK Cancel ESC Page 51 of 64 Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 9 8 Start Stop The operation of the inverter can be stopped and started manually using this menu The Start or Stop status remains unchanged even if the unit losses its power supply Press ok to toggle from one status to the other The display shows the following message Select the desired option and press OK again The stopped status is maintained until the menu is accessed again 12 04 10 09 01 09 ON OFF Change to Stop OK MAIN MENU Change date Start Stop Reset partial data Change inverter number Cancel ESC 9 9 Partial Data Reset The partial counters Part E Tpar con and Npcon are set to zero from this menu Press OK to set the counters to zero The following message is shown on the screen Pressing OK again confirms the selection 12 04 10 09 01 09 MAIN MENU RESET PARTIAL DATA Change date Confirm OK S S Reset partial data
7. 1 CONE chennai A n 20 A NAE MMO ONS rita 20 4 3 Definition of the tasks to be carried out ooccconccoccconcconcconccoonconnnonnncanocanonnncnnnonancnnnnos 20 4 3 1 Inspection tasks roer cs 22 4 3 2 Control tasks criando wu arem 22 o Tas A 22 44 General 018 lt n ee en rene ne neers piaas 22 4 4 1 General risks existing and preventive measures cccooccccoccccocncoocncncnconcncnonnnnnnnnons 22 4 4 2 Additional risks and measures in handling tasks ocooocccococcniconconcocnnconcnnnnos 22 4 4 3 Personal Protective Equipment PPE occocccccccnccccccncnccncnonanocnnnnoncnonancnnnnnons 23 5 tici AU OUD e CETTE I EUM 24 5 1 General requirements for installatiON coocccoccconnconnconncorncornonononcnconocanocononono 24 24 po C Y 7 Page 8 of 64 AAY2000IKI 3 Rex _ Date March 20 11 Installation Manual INGECON SUN SMART TL AAY20001KI03 ingeteum 9 2 FINO The PIE TO The Wall zoe cocci voee pute cuu n tud e ERE Pb ned cto umi PA ep ad 25 9 3 Electrical COINS CU ras 28 5 3 1 Description of cable inlets NETT RTT TETTE 28 5 3 2 Order of connecting the UNlt ccooccccocccccnccocncccnicnnnocannnnonocnnnonanonnnnnnanonannnnaninos 31 A TOV OUIE E E P EAEE E EE E A T I Dee U DUEEUE 32 5 3 4 Connection for communication over RS485 serial line 32 5 3 5 Connection for communicat
8. Grid voltage out of range Chances are that the problem is a power failure It must be borne in mind that the alarms are additive hence when this fault occurs the alarm shown will be 0006h which is the sum of 0002H 0004H When power returns the inverter will restart If not check the connections to the grid If the grid has the appropriate grid quality parameters check the grid connections If the problem persists contact Ingeteam Energy S A 0020H Insulation fault in DC circuit Possible causes are There is an insulation fault on the circuit panels The varistor thermal fuse protection has tripped The fault current or differential current protection has tripped An insulation fault can pose a hazard to personnel The repair of an insulation fault must be carried out by qualified personnel Procedure for determining which of these two conditions caused the insulation fault Check that the insulation fault is not in the solar panel circuit by disconnecting the different circuits f possible connect the inverter to an alternative panel circuit which does not have this problem f the fault persists measure the voltage between each panel array branch and ground f the voltage measured is constant and coincides approximately with open circuit current there is a ground fault in this branch Each branch must be checked f the fault persists after fixing the ground fault check varistor thermal fuse protec
9. all the notices located on the unit Ensure that all the notices are perfectly legible and that those which are damaged or have disappeared are restored AAY2000IKI03 Page 21 of 64 Rev Date March 2011 Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 4 3 1 Inspection tasks May involve opening the housing for visual inspection tasks 4 3 2 Control tasks Tasks to load software from the communications connector 4 3 3 Handling tasks Tasks for the mounting and or replacement of parts switchgear in general arresters etc tasks for disconnecting and reconnecting voltage connecting the inverters to equipment and connecting communications cabling to the equipment All those tasks which are neither Inspection or Control will be considered to be Handling 4 4 General points This section defines the preventive measures to take to carry out all types of tasks on the unit working safely and controlling risks which cannot be avoided Protection against direct contact is by means of the housing which has IP 65 protection class The unit has been tested according to the applicable regulations to comply with the safety requirements the values for insulation distances and leakage paths for the voltages used The tools and or equipment used in handling tasks must have double reinforced insulation class II 4 4 1 General risks existing and preventive measures Impact against immovable objects Inform workers of
10. and maintain their initial electrical properties Check that there is no moisture inside the cabinet If moisture exists dry before making electrical connections Page 39 of 64 i Installation Manual INGECON SUN SMART TL ingeteam AAY20001KI03 y Check the correct fixing of the cabinet components to their corresponding anchorage points The units are cooled by forced convection using six fans three inlet and three outlet each capable of handling a flow of 78 m h P Ensure adequate ventilation of the unit by Checking for obstructions in air inlets and outlets W Checking the status of exhaust fans cleaning and replacing them if necessary Clean vents When on the inverter generates a buzzing sound Check the environment to avoid amplifying or transmitting the buzz The unit should be located in a place readily accessible for installation and maintenance work enabling keyboard handling display reading and access to the unit s various internal components ES t7 Page 40 of 64 AAY2000IKI 3 Rex Y Date March 2011 4 d EL 4 7 L Installation Manual INGECON SUN SMART TL AAY20001K103 O Troubleshooting This is a guide for troubleshooting problems that may arise in the installation and operation of INGECON SUN TL SMART units It also explains how to perform simple operations such as component replacement and unit configuration Troubleshooting for the I
11. not used have been properly sealed Safety measures The front door should be opened only after disconnecting the unit from the grid and the PV array It is also essential to close the unit before connecting it to the PV array or the mains The guarantee does not cover damage caused by inadequate sealing of the unit AAY2000IKI03 Page 37 of 64 Rev Date March 2011 7 t 17 s y HE 7 X AG i 3 i 4j Va od Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 6 2 Start up Once a general visual inspection wiring check and sealing check has been carried out proceed to connect power to the unit while keeping it switched off following the guidelines in the instruction manual for the unit installed The tasks outlined for this step must be carried out with the unit door always closed thus avoiding possible contact with live parts without IP6X protection 6 2 1 Adjustments Change date Go to the CHANGE DATE menu Adjust the date and time of the unit s internal clock The section on Display control explains how to do this Check that the monitored variables have coherent values using the keyboard and flat screen ES Page 38 of 64 AAY20001KI 3 Rev _ Date March 2011 4 4 f pott L Installation Manual INGECON SUN SMART TL AAY 2000IKI03 Preventive maintenance The recommended preventive maintenance tasks must be carried out at least ANUALLY except for those which
12. opening their main circuit connection emitting a signal that is read by the control triggering in turn an alarm and a shutdown of the unit When this occurs the following alarm appears 0x0200 DC circuit protection When this happens the arresters show an error message on their display screen changing colour In these cases INGETEAM ADVISES CHANGING THE ENTIRE ARRESTER BLOCK Page 55 of 64 i j 3 27 74 r t1 s Y HE 7 X v Y od Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 10 3 DC isolating switch INGECON amp SUN SMART TL units can have an optional continuous DC isolator The advantage provided by this isolator is that it can isolate under load in case of emergency In any case we recommend that other than in the case of an emergency the unit be shutdown by means of the display before isolating CAUTION As long as the panels are exposed to the light the DC cables will carry potentially dangerous voltage levels Never handle the connections before disconnecting the inverter from the grid and the PV array 4 Page 56 of 64 AAY 2000IKI 3 Rex _ Date March 2011 f ed Installation Manual INGECON SUN SMART TL AAY 2000IKI03 10 4 Communications SMART TL units are made up of three power modules Each one has its own control card The communications kit is shown on the module 3 control card L C T BH The following sections des
13. status of the process is displayed at the bottom of the screen at the same time Bear in mind that the phase shown in the title is the one on which the AUTOTEST is being performed Phase 2 in the figure and that the phase specified in the Result line is the phase for which data was saved during the last AUTOTEST Phase 1 in the figure The memory has capacity only for the data of one complete AUTOTEST which means that any previous AUTOTEST data is automatically deleted on AUTOTEST to access the menu The first screen lets you select the phase you wish to perfrom the OK 12 00 12 04 10 AUTOTEST Phase 2 Phase 3 12 04 10 AUTOTEST Phase 2 Initiate Autotest Result Phase 1 Status Start The statuses through which the AUTOTEST algorithm passes and which are shown at the bottom of the screen are Status Completed There is no AUTOTEST in progress Status Start An AUTOTEST process is starting Status Vmax When it is evaluating the upper limit for voltage protection This shows the voltage protection value as the algorithm varies it until disconnection is confirmed Status Reconnection Each time a Vmax Vmin Fmax or Fmin status is completed the connection status appears to indicate that it is starting the next AUTOTEST measurement Status Vmin When it is evaluating the lower limit for voltage protection Status Fmax When it is evaluating the upper limit for frequency protection S
14. the Delivery Note sign the MERCHANDISE RECEPTOR SIGNATURE field and return the copy to the return address gt Keep the unit in its packaging until immediately before installation Once unpacked the inverter must be kept in the VERTICAL POSITION at all times to ensure its sealing Unit packaging will be of the following size HEIGHT WIDTH CONTENTS PACKING WEIGHT k LENGTH mm Ingecon Sun 10 TL with foam Ingecon Sun 15 TL Ingecon Sun 12 5 TL NES Cardboard box EN 770 780 300 Ingecon Sun 18 TL NS Never place more than four units on a single pallet Place them vertically and do not pile units on top of each other AAY2000IKI03 Page 15 of 64 Rev Date March 2011 Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 The serial number of the equipment is its unique identifier This number must be referenced in any communication with Ingeteam Energy S A INGETEAM ENERGY S A Ingeteam si Godse ta a imoacer mii 31621 Sariguren Nayere SPAIN TONTA Een com INGECON SUN SMART Ingecon Sun 18 TL Pac 18 kW Vac 3 x 400 Vac a SO d S N 150 550 Vdc 420011041012 fee h LS Il Il 1041012 42001 ii AM ih i Jj If the equipment has been damaged during transport Transport damage 1 do not proceed with the installation 2 notify the distributor immediately within 5 days of receipt If ultimately the unit has to be returned to the manufacturer you must use the sam
15. 1 3 Compliance with regulations This unit can incorporate kits making it adaptable to the regulations for all European countries and countries in other continents 1 3 1 CE marking CE marking is mandatory for the sale of any product within the European Union without prejudice to standards or laws INGECON SUN LITE TL units have CE marking by reason of their compliance with the following directives Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC 4 Page 10 of 64 AAY 2000IKI3 Rex _ Date March 2011 f ed Installation Manual INGECON SUN SMART TL AAY20001KI03 ingeteum To comply with each directive it is sufficient to comply with the parts of the appropriate harmonised standards which are applicable to our equipment 1 3 1 1 Low Voltage Directive INGECON SUN LITE TL units comply with this directive by means of compliance with the applicable parts of harmonised standard EN 50178 Electronic equipment for use in power installations 1 3 1 2 Electromagnetic Compatibility Directive INGECON SUN SMART TL units comply with this directive by means of compliance with the applicable parts of harmonised standards EN 61000 6 2 Electromagnetic Compatibility Part 6 2 Generic standards Immunity for industrial environments EN 61000 6 3 Electromagnetic Compatibility Part 6 3 Generic standards Emission standard for residential commercial and light industrial environments
16. 20 E uw V1 2004 for changes to configuration for ITALY Vac 3 x 400 Vac Two labels will be included together with the unit documentation to ser hz stick under the ratings plate in these cases The illustration shows SNC EID vde where these are to be located 1P65 2011 CE VDE 0126 Mi ald 420011041012 em AAO RTC alle rete Enel Distribuzione NEVER PLACE THE LABEL UNLESS THE INVERTER FULFILS THE IDENTIFIED CONFIGURATION Incorrectly marking a unit can constitute a breach of laws or regulations INGETEAM ENERGY S A accepts no liability for the consequences which can result from erroneous or fraudulent marking of its units due to failure to comply with these instructions 9 5 2 Nominal grid voltage This menu is for configuring the output voltage on the terminal strips It is not used for any of the models to which this manual refers 7 po t et ZOOS Page 49 of 64 po Rev _ Date March 2011 y P Installation Manual fea INGECON SUN SMART TL inge AAY20001KI03 9 5 3 Other adjustments Press OK on the OTHER ADJUSTMENTS option from the CONFIGURATION submenu Press OK to display the upper and lower limit values for the voltage and frequency protections You can browse through the four magnitudes for the value by means of the LA and keys 12 00 12 04 10 12 00 12 04 10 CONFIGURATION OTHER ADJUSTMENTS COUNTRY NORMATIVE
17. CEI 11 20 CEI 11 20 V1 CEI 0 16 CE Marking Page 62 of 64 t Date March 7 Installation Manual INGECON SUN SMART TL AAY20001KI03 AAY2000IKI03 Rev Date March 2011 NOTES Page 63 of 64 N A d Avda Ciudad de la Innovaci n 13 31621 Sarriguren Navarra SPAIN Tel 34 948 288 000 Fax 34 948 288 001 http www ingeteam com Ingeteam Ingeteam Energy S A www ingeteam com
18. Cancel ESC Change inverter number 9 10 Change inverter number From this menu a number is assigned to each phase of the inverter This is required for configuring communications Press OK on the phase whose number you wish to change 12 00 12 04 10 CHANGE INV NUMBER 12 04 10 MAIN MENU Change date Start Stop Reset partial data Phase 2 Change inverter number Phase 3 09 01 09 CHANGE INV NUMBER When you are in the menu of the selected Ex change the inverter number by pressing Aland gt o Press LOK to confirm the number selected Inverter number 101 Confirm OK Cancel ESC ES Page 52 of 64 AAY20001KI 3 Rey Date March 2011 4 y EL 4 Y d Installation Manual INGECON SUN SMART TL AAY 2000IKI03 9 11 Autotest ingeteam In some of the unit configurations there is an additional AUTOTEST submenu In these configurations this additional submenu will appear at the end of the main menu OK Press AUTOTEST on Highlight the phase you wish to test and press 12 04 10 MAIN MENU Start Stop Reset partial data Change inverter number Autotest Once in the menu you can carry out tests on the voltage and frequency protections by varying their limits and checking that they disconnect correctly To do this you can access the START AUTOTEST and RESULT functions can be accessed using the LAN and 5 keys The
19. E IOS d MR 55 10 2 DE arrester kit arado 55 19 3 DC ISOIAUNO SWIC RN RIEN 56 10 4 Communications sn 57 10 4 1 Installing a GPRS modem escena sirnccatueonedp Gubu biu mici ssesbudsdtad oem t pisdecet 58 10 4 2 Installing an Ethernet Card coocccoccconcconcconiconiconnconcnoncnononononononanenanenanos 60 TT SOCCIICAUOINS a 62 AAY2000IKI03 Page 9 of 64 Rev Date March 2011 Installation Manual fea INGECON SUN SMART TL inge AAY20001KI03 1 Overview 1 1 Introduction The purpose of this manual is to describe the INGECON SUN SMART TL units and to give appropriate information for their correct receipt installation start up operation and maintenance 1 2 Description of the unit An inverter is a circuit used to convert direct current to alternating current The function of the INGECON amp SUN SMART TL units is to convert the direct current generated by photovoltaic solar panels to alternating current and so enable it to be fed to the electricity grid PSI grid 1 2 1 Models The main models in the INGECON SUN SMART TL range are INGECON SUN 10 TL NGECON SUN 12 5 TL INGECON SUN 15 TL INGECON SUN 18 TL 1 2 2 Options All these models in the INGECON SUN SMART TL range can incorporate the following options DC isolating switch Overhead RS485 communications connector FV Type 3 or Type 4 quick connectors DC and or AC arresters RS485 ethernet communications card GSM GPRS modem
20. Ingeteam INGECON SUN SMART TL Ingecone Sun Smart TL Installation manual gt o m co Ss z N gt lt lt Installation Manual fear INGECON SUN SMART TL inge AAY20001KI03 The copying circulation or use of this document or its content requires written permission Any breach thereof will be reported for damages All rights reserved including those resulting from patent rights or design registration The conformity of the document content with the hardware described has been checked However discrepancies may exist No liability will be accepted for lack of total agreement The information contained in this document is regularly revised and it is possible that there may be changes in subsequent editions This document is subject to change The copy distribution or use of this document or of its content requires written authorisation Any breach thereof will be reported for damages All rights reserved including those of patent rights or design registration The conformity of the document content with the hardware described has been checked However discrepancies may exist Liability will not be assumed for total concordance The information contained in this document is regularly revised and it is possible that there may be changes in subsequent editions Other functions may be available which are not covered by this document This document may be changed ES Page 2 of 64 AAY2000IKI 3 Rev _
21. NGECON SUN SMART TL unit must be performed by qualified personnel in compliance with the general safety instructions in this manual 8 1 LED messages Some of the LEDs indicate some kind of problem in the PV installation 8 1 1 Green LED This is the LED that should light up in normal start up and operating conditions while the others remain off It has three modes 8 1 1 1 1 second flashing This type of blinking indicates that the PV array is feeding the right amount of voltage to the inverter and it is about to start up In this state the inverter checks the grid parameters to feed current into the grid at the latter s precise voltage and frequency This process takes about 1 minute 8 1 1 2 3 second flashing Standby due to low solar radiation Flashing every 3 seconds This alarm is triggered when the PV array does not receive enough solar radiation to supply the minimum voltage required by the inverter to inject power This occurs commonly between sunset and sunrise or at times when rain clouds or other atmospheric phenomena produce overcast conditions above the PV array If this situation occurs on a day which is not particularly dark check that the panels are clean and properly installed 8 1 1 3 Steady light Inverter connected to the grid 8 1 2 Orange LED This LED indicates that alarms have been set off in the inverter 8 1 2 1 0 5 second flashing lf accompanied by the message COMMS on the display mean
22. ON SUN SMART TL inge AAY20001KI03 5 4 Electrical disconnection To disconnect the unit follow the steps presented in the Section Order of connecting the unit of this manual in reverse order Take careful note of the following warning There are electrical capacitances in the unit which can maintain high voltages even after having disconnected the inverter from the solar panels and the grid And remember Ingecon Sun units may only be opened by authorised personnel During installation and maintenance operations on the units the use of personal protective equipment hard hat gloves and safety footwear is mandatory Do not touch the sides of the inverter They may reach high temperatures Installation work requiring opening the unit should be done in a dry environment so that no moisture left inside could condense and damage the electronics Ingeteam Energy S A is not liable for any damages caused by improper use of their equipment d Page 36 of 64 AAY20001K163 Rev _ Date March 2011 po Installation Manual INGECON SUN SMART TL AAY20001K103 6 Commissioning 6 1 Checking the unit This section contains instructions on how to make the unit work once correctly wired and closed INGECON SUN SMART TL units manage a generating installation or part of one The correct condition of this installation must be checked before start up Each installation is different depending on it
23. SMART TL units are designed to operate between 20 C and 70 C To operate in HT mode maximum ambient temperature must not exceed 45 C To operate in HP mode maximum ambient temperature must not exceed 40 C Page 12 of 64 AAY 2000IKI3 Rex _ Date March 2011 Installation Manual INGECON SUN SMART TL AAY20001KI03 ingeteum 2 1 4 Atmospheric conditions The ambient air must be clean and relative humidity must not exceed 50 at over 40 C Higher levels of relative humidity up to 95 can be tolerated at below 30 C It should be borne in mind that moderate condensation may occasionally occur as a consequence of temperature variations and apart from the unit s own protection vigilance of these units is necessary once they have been started up on sites where it is suspected that the conditions described above will not be present 2 1 5 Pollution degree The pollution degree for which the units have been designed is level 3 2 1 6 Noise pollution When on the inverter generates a slight buzzing sound Do not place it in an occupied room or on light supports which might amplify this buzz The mounting surface must be firm and appropriate for the weight of the unit 2 1 7 Ventilation A clear space must be kept no less than 30 cm from the top bottom and sides of the unit as well as 80 cm from the front to allow the door to be opened Only in this way will the unit s cooling system be able to operate correc
24. TRY NORMATIVE first press the LA key followed by ESC and then keep them both pressed for 4 seconds A list of COUNTRIES will appear on the screen AAY2000IKI03 Rev Date March 2011 The following screen will appear 12 00 12 04 10 COUNTRY NORMATIVE Country ESPANA Normative RD1663 Code 1 STE 12 00 12 04 10 COUNTRY NORMATIVE DANMARK ESPANA ENGLAND gt DEUTSCHLAND ITALIA Page 47 of 64 Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 The gt sign shows the current selection Select the COUNTRY NORMATIVE you wish to change using the COUNTRY NORMATIVE S and gt key then press LOK The following screen will be shown Press OK to confirm ESPANA RD1663 gt gt gt gt gt gt DEUTSCHLAND VDE0126 1 1 CONTINUE Confirm OK Cancel ESC CAUTION Changing from any other configuration to ESPA A is irreversible using the instructions in this manual Contact the Sales Department of INGETEAM ENERGY S A if you wish to change the configuration of any other country When SPAIN is changed to any other Country you will be asked for PASSWORD 2 PASSWORD 2 is personal and non i transferable and will appear on the following screen COUNTRY NORMATIVE Enter PASSWORD 2 Paena D On pressing Ok a screen will appear showing the status while configuration is taking place It
25. Y2000IKI03 Page 23 of 64 Rev Date March 2011 Installation Manual ewm INGECON SUN SMART TL inge AAY20001KI03 5 Installation The installation of the Ingecon Sun inverter must be performed by qualified personnel in compliance with the general safety instructions in this manual The inverter handles voltages and currents that can be dangerous Before installing the INGECON SUN SMART TL the packaging must be removed taking special care not to dam age the housing The inside of the box must be checked to ensure there is no moisture If there are signs of moisture the unit must not be installed until it is completely dry All installation operations must obey the regulations in force Before starting the actions described under this point it is important to identify each of the parts described in it and to have gathered the necessary tools to carry them out 5 1 General requirements for installation The unit s environment must be appropriate and meet the guidelines described in Chapter 2 Additionally the parts used in the rest of the installation must be compatible with the unit and comply with the applicable legislation Pay special attention to Ventilation and the space for work which must be suitable for maintenance tasks according to the applicable regulations in force The external connection devices which must be suitable and sufficiently close as laid down in the regulations in force The c
26. aces GRID VOLTAGE GROUNDING 50 20 Hz OTHER ADJUSTMENTS To change the values of these magnitudes hold the key 12 00 12 04 10 down for 4 seconds The following screen will appear requesting a password in this case PASSWORD 3 As for OTHER ADJUSTMENTS the other options in the CONFIGURATION submenu enter Password 3 PASSWORD 3 individual and non transferable for each inverter and press OK og ok Each time and are pressed four screens will appear offering the option to change the upper and lower voltage and frequency protection limits Shown as an OTHER ADJUSTMENTS example is the screen for changing the upper frequency limit Fac max Press OK The value for the maximum frequency limit can be varied using the 25 and keys Once you have selected the desired value press OK Change Ok 50 20 Hz The following screen will appear requesting confirmation or 35 00 VV cancellation of the modified value using the OK or ESC respectively OTHER ADJUSTMENTS The unit must be restarted for the new configuration to be operational To do this open the DC isolating switch and Haas wait 5 seconds after the display goes dark The unit will be reinitialised when switched back on Change Ok 50 20 Hz Change Ok Cancel ESC Changing the protection limits for voltage and frequency may result in failure to comply with the standards to
27. am 10 1 AC arrester kit SMART TL inverters may optionally have built in overvoltage protection on the AC input Overvoltage protection is Type II with the following characteristics Nominal current 20 kA 8 20 uS Maximum current 40 kA 8 20 uS Residual voltage 1 5 kV Overvoltage protections limit the power coming from the grid due to atmospheric disturbances and transient overvoltages on the grid Their power dissipation is limited If the protections exceed the power they can withstand they self protect by opening their main circuit connection emitting a signal that is read by the control triggering in turn an alarm and a shutdown of the unit When this occurs the following alarm appears 0x0100 AC circuit protection When this happens the arresters show an error message on their display screen changing colour In these cases INGETEAM ADVISES CHANGING THE ENTIRE ARRESTER BLOCK 10 2 DC arrester kit AAY2000IKI03 Rev Date March 2011 SMART TL inverters may optionally have built in overvoltage protection on the DC input Overvoltage protection is Type II with the following characteristics Nominal current 20 kA 8 20 uS Maximum current 40 kA 8 20 uS Residual voltage 4 5 kV Overvoltage protections limit the power coming from the PV array due to atmospheric disturbances and transient overvoltages Their power dissipation is limited If the protections exceed the power they can withstand they self protect by
28. ange 0400H Manual stop 0800H HW error 1000H Instantaneous grid overcurrent 2000H Detection of island mode operation 8000H Hardware fault alert The value displayed in Inv Alarm can be the result of the hexadecimal sum of two or more of the values listed above E g Inv Alarm 0006H means that The Grid Frequency and Voltage are out of range Numlnv Number allocated to the inverter through the menu accessible in the display Cod1 Unit operating code This can be requested from Ingeteam s customer services Cod2 Unit operating code This can be requested from Ingeteam s customer services SN Serial Number Screen 4 TotE Total energy in kWh delivered by the inverter to the grid from the date it was manufactured Recording the serial number of the equipment marks the start of this power log T Con Number of hours the inverter has been connected to the grid Num Con Number of grid connections made during all hours of operation Screen 5 ParE Total energy in kWh delivered by the inverter to the grid since the last time the counter was reset Tp Con Number of hours the inverter has been connected to the grid since the counter was last reset Npcon Number of grid connections since counter was last reset d Page 46 of 64 AAY2000IKI 3 Rev _ Date March 2011 f ed Installation Manual INGECON SUN SMART TL AAY 2000IKI03 Screen 6 FW Ver Unit firmware version DFWVer Unit display firmware vers
29. ation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 5 3 1 4 Multipurpose cable gland Multipurpose cable glands can be requested as an option If these are not requested the plate will be supplied with its hole pre cut to be able to open it If the hole is opened and a cable gland is not fitted for correctly installed IP 65 units the unit will lose its IP 65 protection rating Four M16 glands and one M20 gland suitable for installing communications kits Once the connection has been made check that the cable glands used have been closed appropriately to guar antee sealing of the box A closure which is not sealed may allow moisture to enter and seriously damage the unit invalidating the manufac turer s warranty in addition If a knock out which is not to be used is opened accidentally or one which has been fitted with a cable gland is no longer used these open orifices must be closed with a sealing plug which maintains the unit s hermetic seal See the Section Closure of the unit y EL Page 30 of 64 AAY20001KI 3 Rey _ Date March 2011 4 y if A Y Installation Manual INGECON SUN SMART TL AAY 2000IKI03 5 3 2 Order of connecting the unit The basic connections to be made with the inverter are as follows in this order Connecting auxiliary equipment optional Communication line optional Connecting the inverter to the grid Connecting the DC cables from the PV array The fo
30. cribe the installation of the GPRS modem card and the ethernet card For more information about other available communications kits as well as other types of interface with different equipment please consult the Installation Guide for Communications Devices AAX2002IKI01 AAY2000IKI03 Page 57 of 64 Rev Date March 2011 AAY2000IKI03 Installation Manual ingeteam INGECON SUN SMART TL 10 4 1 Installing a GPRS modem The steps for installing the modem are as follows 1 Fit the GPRS modem card to connectors J11 and J12 of the Module 3 control card a J4 RS485 Bus 5 PIN1 RS485 B PIN2 RS485 A Al J11 PIN 4 GND J12 J3 PC PIN1 RS485 B PIN2 RS485 A IM i As JER AAE ZAE E mua PIN 4 GND Antenna connector 2 Connect connector J1 of wiring AQLOO89 to connector J4 of the GPRS modem card Disconnect the end of wiring AQLO121 which is connected to connector J19 of the Module 3 power card and con nect it to connector J2 of wiring AQLO089 AQLO121 E 4 f ed AAY 2000IK1037 Rey _ Date March 20 11 Page 58 of 64 Installation Manual INGECON SUN SMART TL AAY 2000IKI03 3 Remove the cut out shown in the figure and fit the BLACK M 23 gland with its nut 4 To install the antenna place the end of the cable with the antenna connector through the PG and to the antenna connector on the GPRS modem card Cable from the modem to the right hand side and to th
31. done manually as the START or STOP condition does not change even when the unit loses power In the main menu highlight the START STOP option and press OK to toggle the status The display shows the following message Highlight the desired option again and press AAY2000IKI03 Rev Date March 2011 OK 12 04 10 MAIN MENU Start Stop Partial Data Reset Change inverter number Other adjustments 12 00 09 01 09 ON OFF Change to Stop OK Cancel ESC Page 43 of 64 7 t 17 s 7 X A 3 e 71 Va od Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 Q Display control INGECON amp SUN SMART TL inverters incorporate a display and keypad unit to interface with the installer and the user E This interface allows the display of the main internal parameters and the configuration of the entire system during installation Parameters variables and commands are organised as menus and submenus 9 1 Keypad and LEDs The keypad has four keys Esc To exit a parameter leave a menu and returning to the next level up in the structure to not confirm ESC a change or not accept a proposal pm Up With this key you can scroll up the list of parameters or folders within the same level or increase the value of an editable parameter by one base unit VLA Down With this key you can scroll down th
32. e cut out on the bottom of the equipment housing Finally use flanges to fix the cable and the antenna to the RS485 connector A o ENG AAY20001KI03 Page 59 of 64 y Rev _ 4 Fi Date March 2011 3 d p i RNY ane gt Installation Manual ingeteam INGECON SUN SMART TL AAY2000IKI03 10 4 2 Installing an Ethernet card The steps for installing the ethernet card are as follows 1 Fit the ethernet card to connectors J11 and J12 of the Module 3 control card J4 RS485 Bus PIN1 RS485 B PIN2 RS485 A J11 PIN 4 GND J12 RJ45 e T Eu a EB gg cee ee 2 Connect connector J1 of wiring AQLOO89 to connector J4 of the ethernet card Disconnect the end of wiring AQLO121 which is connected to connector J19 of the Module 3 power card and con nect it to connector J2 of wiring AQLO089 J4 J1 AQL0089 vee AQLO121 E 4 Page 60 of 64 AAY 2000IKI3 Rex _ Date March 20 11 f ed Installation Manual INGECON SUN SMART TL AAY 2000IKI03 3 Remove the cut out shown in the figure and fit the BLACK M 23 gland with its nut 4 To install the network cable place the end of the cable with the RJ45 through the PG and to the RJ45 connector on the ethernet card Cable from the card to the right hand side and to the cut out on the bottom of the equipment housing A o NY AAY2000IKI03 Page61 of 64 f Rev GK Date Ma
33. e list of parameters or folders within the same level or decrease the value of an editable parameter by one base unit OK OK Serves to accept a parameter as valid to enter a lower level menu in the structure to confirm a change or accept a suggestion The front panel has three LEDs Q Green LED 1 second flashing Start up process 3 second flashing Standby due to low irradiance On Inverter connected to the grid Orange LED 0 5 second flashing The external fan is not working correctly The unit has lost communication 1 second flashing The internal fan is not working correctly 3 second flashing Inverter limiting power due to high temperature On Presence of alarm Q RedLeED On Manual shutdown 9 2 Display The display features 12 00 12 04 09 The current date and time on the top line The internal clock automatically changes the time from summer to winter and vice l S SMART 18 0 TL versa The middle diagram shows on the right hand side the instantaneous P 17887 W voltage values from the PV array of the three strings which feed 305 V 230 V 50 00 Hz each of the three power cards and on the left hand side the power oe M y io Ha injected by the inverter and the voltage and frequency of each phase of the grid ES t7 Page 44 of 64 AAY2000IKI 3 Rex Y Date March 2011 f 4 7 A Installation Manual INGECON SUN SMART TL AAY2000IKI03 ingeteam 9 3 Main Menu
34. e original packaging Recycling the Packaging All the packaging can be delivered to a non hazardous waste management company In any event each part of the packaging may be recycled as follows Wood crate pallet corner protectors Authorised non hazardous waste agent Plastic bag and bubble wrap Recyclable plastic container and packaging Cardboard Recyclable paper and cardboard container d Page 16 of 64 AAY20001KI 3 Rev _ Date March 2011 f ed Installation Manual INGECON SUN SMART TL AAY 2000IKI03 3 3 Handling and transport Correct handling of the units is vitally important in order to Prevent damage to the packaging which enables them to be kept in optimum condition from shipping until they are unpacked Avoid knocks and or falls which may harm their mechanical characteristics e g cause incorrect closure of doors loss of IP rating etc Avoid as far as possible vibrations which may cause subsequent malfunction If you observe any anomaly please contact INGETEAM immediately Appropriate transport and storage of the unit are the necessary first steps for correct use and operation Taking that indicated at the beginning of this section into account and as a preventive measure INGETEAM recommends the use of transport companies specialised in the transport of special and or fragile equipment All units packaged according to the Section Receipt and unpacking of the unit must be handled wi
35. f Contents Table 0r Conte sien ito pase iii bobadas 8 UESTRAE OSEE 10 AMOO ota 10 1 2 Description of the ERE canoa ita 10 NIS MOI Soo abit 10 AAA o OO PA 10 1 3 Compliance with regulations Susaeta aida eine 10 dl CE MIKINO o E A O m 10 1 3 2 VDE0126 1 1 disconnection device insert 11 1 3 3 Regulations for connection to the ENEL Distribuzione grid 11 1 3 4 Engineering Recommendation G83 1 ocoocccncccccccocccoccconoconoconocoronorocnnnonnnonnnnnons 11 1 3 5 Compliance with Australian and New Zealand regulations 11 2 System dllescriptiON ooccoccccncoccconcconccnnconnconcconcnnncnnrcnnrnnncnnnennrnnnrnnrrnrnnnrnanennrnanenns 12 2 li LOCO ria 12 2 ok VAP OFM RC anatomia 12 AA A 12 2 1 3 Ambient temperature eno oercicd s 12 2 1 4 Atmospheric conditions crias 13 Ze o os Ae 13 Za lO NOISE DOLO ocre cont 13 1 o sieayoiauaedmuascenriesdddeco A 13 2 2 Environmental characteristics ooccoccconconcccnconeconeononononcncanconncnnnnnonanonnncancnnonanonos 14 2 9 EMC T gull ele Scirocco E 14 3 Operating conservation and transport conditions 15 ON SN NEN A 15 3 2 Receipt and unpacking of the unit oocccocccocccocccocccocncocncncnnocnnncnonnnonnnnnnnoncnconocanonoso 15 3 3 Handling and transport MERE 17 4 OO AO ire 18 A e EEE 18 o Waste ACI VC ciao 18 4 Safety WAS FUC UOS pisito 20 4
36. has 3 independent MPPTs each with the same nominal power i e one third of the nominal power of the whole unit The inverter is connected to the PV array by means of three sets of quick connect terminals specifically designed for the purpose This type of quick connect terminal requires the use of specific tools Each PV input set of quick connectors is suitable for connecting up to four STRINGS The three PV arrays must be independent If the same PV array is connected to more than one of them the unit will not be connected to the grid Never forget that whenever they receive solar radiation the panels generate voltage in their terminals The inverter can therefore have voltages of up to 550 volts inside even when not connected to the grid The inverter has a maximum system voltage of 550 Vdc Check that the PV array configuration cannot supply this voltage to the inverter even under the most adverse conditions e g an ambient temperature of 10 C In the case of damage due to the DC voltage exceeding 550 Vdc Ingeteam Energy S A sill accept no liability for such damage CAUTION Connect the positive pole of the solar panels to the terminals marked and the negative pole to the terminals marked The inverter s factory fitted terminals support a maximum current of 20 amperes AAY2000IKI03 Page 35 of 64 Rev Date March 2011 7 A t s Y HE 7 X AGE i 3 i 4 Va od Installation Manual fem INGEC
37. hecking that there is no voltage wearing dielectric gloves and safety goggles approved for electrical hazards is required After disconnecting the unit from the PV array and the grid wait at least 10 minutes before opening the door Internal capacitances may still hold hazardous voltages As long as the panels are exposed to the light the DC cables will carry potentially dangerous voltage levels Once the unit has been mounted in its final position and has been solidly secured make the electrical connections to it 5 3 1 Description of cable inlets INGECON SUN SMART TL units have cable inlets through the bottom of the housing Each type is described below 5 3 1 1 Quick connectors for DC connection The units have three sets of CD inputs each suitable for connecting up to 4 strings The connectors supplied as standard are FV Type 4 quick connectors though Type 3 connectors may be specially ordered ES Page 28 of 64 AAY20001KI 3 Rey _ Date March 2011 y EL 4 Y d Installation Manual INGECON SUN SMART TL AAY 2000IKI03 5 3 1 2 Connector for AC C 9000 6000 6000 6006000602 6000 An AC bayonet connetor See Mains connection 5 3 1 3 Quick connector for communications This is a female quick connector A cable with a compatible connector must be connected ES Y fp m A AAY2000IKI03 Page 29 of 64 fv Rev _ Date March 2011 Dy 4 7 7 Install
38. ho have access to parts of the installation into account All equipment must be appropriate to protect exposed workers against the risk of di rect or indirect contacts In any case the electrical parts of the work equipment must comply with that laid down in the corresponding specific regulations All workers who carry out work outdoors will suspend their work in the case of storms rain or strong winds snow or any other unfavourable environmental condition which makes visibility or handling tools difficult Work on installations directly connected to overhead electricity lines must be interrupted in the case of storms INGETEAM accepts no liability for any damages caused by improper use of the equip ment Any work carried out on any equipment which implies a modification of the original electrical arrangements must be proposed in advance to INGETEAM These must be studied and approved by INGETEAM The necessary means must be arranged to prevent people from outside the installation approaching or handling the equipment Care people working signs like the one to the right Elements for setting or mechanical locking using padlocks and keys for automatic mechanisms of appropriate models gt PPE PRE Nh ge These instructions must be easily accessible close to the unit and located with in reach of all users Before installation and start up please read these safety instructions and warnings carefully as well as
39. ible service life for the unit and the devices to which it is connected 4 3 Definition of the tasks to be carried out Installation start up inspection and maintenance operations may only be carried out by personnel appropriately qualified and trained in electrical subjects hereinafter qualified personnel You are reminded of the obligation to comply with the legislation applicable to electrical work The fact that the various compartment housings are open in no way implies the ab sence of voltage Only qualified personnel following the safety guidelines described in this document may access the compartments 4 Page 20 of 64 AAY 2000IK1037 Rex _ Date March 2011 frm Installation Manual INGECON SUN SMART TL AAY 2000IKI03 The set of conditions listed below should be considered as minimum requirements It is always preferable to shut off the general power Installation defects may result in unwanted feedback Danger of electric shock In addition to the safety measures indicated in this manual the general measures that apply in this area specific to the installation country etc must be taken into account The electrical installation must not involve a risk of fire or explosion Workers must be duly protected against accident risks from direct or indirect contact The electrical installation and protection devices must take the voltage the external determining factors and the competence of the people w
40. ical equipment to their personnel and for familiarising them with the contents of this manual CAUTION Opening the doors to the different cubicles does not imply lack of voltage inside Only qualified personnel may open them following the instructions in this manual CAUTION There is a risk of electric shock even after disconnecting the network and PV array d Page 4 of 64 AAY 2000IKI 3 Rex _ Date March 2611 f Z Installation Manual INGECON SUN SMART TL AAY20001KI03 AAY2000IKI03 Rev Date March 2011 CAUTION Carry out all control and handling without voltage As a minimum security measure in this operation the so called five golden rules should always be followed 1 Disconnect 2 Prevent any possible feedback 3 Check there is no voltage 4 Ground and short circuit 5 Protect from live elements if any and put up safety signs around the work zone Until these five steps are completed the work area cannot be considered voltage free and any work performed will be considered to be work on live equipment Following is a list of the basic obligatory safety standards for each country RD 614 2001 in Spain CEI 11 27 in Italy DIN VDE 0105 100 and DIN VDE 1000 10 in Germany UTE C15 400 in France CAUTION Compliance with the safety instructions set out in this manual or in the suggested legislation does not imply exemption from other specific standards for the installatio
41. ing communications card See AAX20021KH01 Installation Guide for Communications Devices 4 Page 32 of 64 AAY 2000IK1037 Rex _ Date March 2011 f ed Installation Manual INGECON SUN SMART TL AAY20001KI03 ingeteam 5 3 6 Mains connection The inverter s metal parts unit ground are electrically connected to the ground pin in the grid connection quick connector To ensure the safety of personnel this terminal must be connected to the installation s ground Connection of network neutral three phases and ground to the inverter is via a bayonet connector with five terminals The AC bayonet connector is suitable for cables from 13 to 20 mm diameter The following sequences must be followed during installation 1 Cut and strip the cables as shown in the figure 54 5 PE 55 Note For cables from 16 to 20 mm cut the inside of the internal ring in the sealing gasket 2 Install as shown in the figure 3 Connect the cable ends to the connector terminals according to the pins shown in the figure Tightening torque 0 7 Nm 1 N Neutral 2 L1 phase 3 L2 phase 4 L3 phase _ Ground PRECAUTION Observe the pin assignations on the AC bayonet connector Applying the wrong pins could lead to the destruction of the equipment The diagram shows the connections inside the AC connector 4 Screw the housing to the connector by pushing the outside ring on the connector towards the housing Tigh
42. ion D Boot Version of the display program enabling firmware housing 9 5 Configuration Enables verification of certain parameters for which the inverter has been configured Access restricted to installer Press LOK on the CONFIGURATION option in the MAIN MENU Giving access to the following screen 12 00 12 04 10 12 00 12 04 10 MAIN MENU Monitoring Configuration Language Change date CONFIGURATION COUNTRY NORMATIVE GRID VOLTAGE GROUNDING OTHER ADJUSTMENTS Do not change any of these parameters if you are not the installer and you are not completely sure INGETEAM ENERGY S A accepts no liability for damage to the unit or the installation due to configuration changes The following passwords are necessary for some configuration changes CODE 1 PASSWORD 2 PASSWORD 3 Given that configuration changes occur in extraordinary installation situations the passwords are not supplied with the unit but rather need to be requested from INGETEAM ENERGY S A s Commercial Department The menu will display only the configurations corresponding to the device hardware The various available configuration changes are described below 9 5 1 Country Normative Press OK on the COUNTRY NORMATIVE option from the CONFIGURATION submenu 12 00 12 04 10 CONFIGURATION COUNTRY NORMATIVE GRID VOLTAGE GROUNDING OTHER ADJUSTMENTS In order to make a change to COUN
43. ion by other means sees 32 5 3 6 Mains connection ssvsaneiidkotixt x dacennactxi rimis E Elan diete ola cena DE PI RIMIS 33 5 9 7 COANECHON to the PV aray carr art UO 5 4 Electrical diSCOITIe6LIOLTcssssseseriessxedessasutrxvus ek RE U PUN as 36 6 Commissioning eeeeseeeseeniee inen enm hhn nnne nnn h una heh ash u asas a uana nenen nana 37 01 CSCIC REUN MR 3f NNI seien MNT 37 TESTE U E S as 38 A IMONI ea E E A 38 PReventive MamtenancCe arier E E iia 39 o IFOUDIESNOONO ari aia centeweaddanstennagead 41 8 1 LED messages cuisine 41 Dt Green A E E E E AA E 41 OA 41 O C 43 S DISP CONT Orna c 4 9 1 Keypad and RD 44 de BISP as ada 44 SENE Uii mr 45 SE MONON eR otc 45 J9 S enero p MER 47 9 5 1 Country reir il i r 47 99 2 Nominal grid volage stories eee 49 9 5 3 Other adjustments catar 50 96 gt 62 02 Le O NU PP eaen a eana ea EE eaS e 51 AE aa 51 TS MEA O aa 52 g9 FA ATA ROS aE E E E E EEE E E N E 52 9 10 Change inverter NUMDeT oocccccncccccccccccocncconccnonncnnonnnnnonnnonannnnnnnnnnnonannnnanonaninnnnnnnnnns 52 A TPCTREE m o3 10 Kits and Accessories eelleeseeeeeee unen enne nnne nenne nnn nnn nnn n nana 54 SE
44. ion is shown in the following images o WW ee eee E El AAY2000IKI03 Rev Date March 2011 Page 19 of 64 Installation Manual Me INGECON SUN SMART TL inge AAY20001KI03 4 Safety instructions 4 1 Content This section contains safety instructions which must be followed when installing operating and accessing the unit Failure to comply with the Safety Instructions may cause injury or even death or cause damage to the unit Read the Safety Instructions carefully before working on the unit 4 2 Symbols The warnings advise of conditions which may cause serious injury or death and or damage to the equipment The means of avoiding the hazard to both people and the unit is indicated along with the warning The symbols and an explanation of their meaning can be seen below Danger high voltage Stay clear Warning of high voltage warns of high voltage which can cause injury or even death and or damage to the equipment General warning warns of conditions which can cause injury and or damage to the equip ment Care hot surface warns of the existence of hot parts which can cause serious burns The specific sarety warnings and notes which affect specific tasks are included in each affected chapter and are repeated and completed within each chapter in the corresponding critical points Please read this information carefully as it is written for your personal safety and to ensure the longest poss
45. lation Manual INGECON SUN SMART TL AAY20001KI03 ingeteum POTENTIAL HAZARDS FOR THE EQUIPMENT The main damage that the unit may suffer due to incorrect use are shown below CAUTION Ventilation The unit requires quality air flow while it is operating Keeping the unit in the upright position and the inlets free of obstacles is essential for this air flow to reach the inside CAUTION Connections After all duly authorised handling check that the inverter is ready to start operation Only after this can it be connected following the instructions in the manual CAUTION Electrical damage Do not touch boards or electronic components The most sensitive components can be damaged or destroyed by static electricity CAUTION Operation Do not disconnect or connect any terminal while the unit is operating Disconnect and check for absence of voltage first PERSONAL PROTECTION EQUIPMENT PPE CAUTION The standard personal protective equipment is Safety goggles for mechanical hazards Safety goggles for electrical hazards Safety footwear Helmet The situations in which each is used is specified in the Section Safety Instructions CAUTION Operation Do not disconnect or connect any terminal while the unit is working Disconnect and check for absence of voltage first AAY2000IKI03 Page 7 of 64 Rev Date March 2011 Installation Manual fea INGECON SUN SMART TL inge AAY20001KI03 Table o
46. liance with this standard must be requested on ordering the unit AAY2000IKI03 Page 11 of 64 Rev Date March 2011 71 3 27 74 r t1 s y HE 7 X v Y od Installation Manual fea INGECON SUN SMART TL inge AAY20001KI03 2 System description 2 1 Location INGECON SUN SMART TL units can be located in practically any environment favourable for PV farms Guidelines are provided in this section for choosing a suitable environment and adapting the unit to it properly 2 1 1 Environment Place the units in a place which is accessible for installation and maintenance work and which permits use of the keyboard and the reading of the front indicator LEDs Do not place any object on top of the unit Caution Do not place any material sensitive to the high surrounding air temperatures close to the inverter Avoid corrosive environments 2 1 2 IP rating INGECON SUN SMART TL units have an IP level of protection against external agents which enables them to be installed outdoors IP65 means that the unit is fully protected against the ingress of dust and also against water jets from any direction as defined for this level of protection in standard IEC60529 However excessive moisture can cause a safety shutdown of the unit to protect it Hence the following is recommended Locate the units in a place protected from the rain 2 1 3 Ambient temperature INGECON SUN
47. llowing sections describe how to make these connections AAY2000IKI03 Rev Date March 2011 Page 31 of 64 Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 5 3 3 System layout The layout will correspond to those in the figures in the majority of installations The regulations applicable to each installation and to each country in which the inverter is located must always be observed DC DC ar breaker resters pes p 8 A PVinput1 ES Inverter AC ar Electricity com resters pany panel n cr ua mE mum J Pd PVinput2 di l hermomagheti drcutt breaker 7 Optional PE Optional 5 3 4 Connection for communication over RS485 serial line All INGECONG SUN SMART TL units have communication over an RS485 serial line As the RS485 communica tion board is already wired to the female Hartingconnector simply plug in a male connector of the same type Refer to AAX20021KH01 Installation Guide for Communications Devices for how to wire correctly the male con nectors which need to be plugged into the connector on the inverter This connector can be supplied by Ingeteam if requested together with the unit 5 3 5 Connection for communication by other means At the request of the installer inverters may optionally incorporate hardware for communicating via GSM GPRS telephone Ethernet In all these units the auxiliary signals connect directly to the correspond
48. n place country or other circumstances that affect the inverter CAUTION Required to check there is no voltage Use Category lll 1000 Volt measuring instruments Ingeteam Energy S A is not liable for any damages caused by improper use of their equipment Page 5 of 64 Page 6 of 64 Installation Manual INGECON SUN SMART TL AAY2000IKI03 POTENTIAL HAZARDS FOR PEOPLE The main injuries to people which may result from incorrect use of the equipment are shown below DANGER Electric Shock The equipment can remain charged even up to 5 minutes after disconnecting the PV array and mains power Carefully follow the mandatory steps in the manual for removing the voltage DANGER Explosion There is a very low risk of explosion in very specific cases of malfunction The casing will protect people and property from the explosion only if it is correctly closed DANGER Crushing and joint injuries Always follow the indications in the manual on moving and placing the unit The weight of this unit can cause lesions serious injury and even death if not handled correctly CAUTION In Inspection Control and Handling tasks the requirements laid down in the Section Safety Instructions must be followed carefully DANGER High temperature The flow of air from the side outlets can reach high temperatures which can cause injury to people exposed d AAY20001KI 3 Rev Date March 2011 po Instal
49. n HYBRID single phase Spanish AAR2000IKH01 English AAR2000IKI01 Ingecon HYBRID MS Spanish AAR2000IKH02 English AAR2000IKI02 Page 3 of 64 iy A d Installation Manual fear INGECON SUN SMART TL inge AAY20001KI03 IMPORTANT SAFETY CONDITIONS KEEP THESE INSTRUCTIONS IN A SAFE PLACE This manual contains important instructions for the installation handling and use of the following models INGECON SUN 10 TL INGECON SUN 12 5 TL INGECON SUN 15 TL INGECON SUN 18 TL and any models derived from these CAUTION The operations described in the manual may be performed only by qualified personnel All applicable safety related for electrical work must be complied with Danger of electric shock The entire manual must be read and understood in full prior to manipulating installing or operating the unit CAUTION The status of qualified personnel referred to in this manual will be as a minimum that which meets all the standards regulations and laws regarding safety applicable to the tasks of installing and operating this unit The responsibility for designating qualified personnel will always fall to the company to which the personnel belong It is necessary to decide which workers are suitable or not for carrying out specific work to preserve their safety at the same time as complying with occupational safety legislation These companies are responsible for providing appropriate training in electr
50. ng wall plugs and stainless steel screws to prevent corrosion The use of the appropriate screws minimum external diameter 6 mm washers and wall plugs minimum external diameter 18 mm is recommended to secure the plate Suspend the unit from the plate Screw on the bottom attachment Check that the unit is well secured ES Page 26 of 64 AAY20001KI 3 Rey _ Date March 2011 4 y EL 4 4 Y d Installation Manual INGECON SUN SMART TL AAY2000IKI03 ingeteam The four upper drilled holes are made first The measurements to be used are shown in the figure The bottom hole must be drilled when the unit is hung on the wall The figure also shows the approximate distances between the horizontal line formed by the four upper drilled holes and where the bottom hole will be AAY2000IKI03 Page 27 of 64 Rev _ Date March 2011 Dy p 7 Installation Manual fem INGECON SUN SMART TL inge AAY20001KI03 5 3 Electrical connection Before opening the front door ensure that there are no live voltages inside the cabinet This requires disconnecting the unit from the PV array and power supply It is also essential to close the unit before connecting it to the PV array or the mains In inspection control or handling tasks Conduct an electrical test to check that neither the no part of the unit is connected electrically to the grid or any of the photovoltaic panels When c
51. nutes for the internal capacitances to discharge the hot parts to cool and the fan blades to stop turning V Open the door and discharge the Vbus by means of a suitable discharge resistance between the VBUS and VBUS Check there is no voltage To carry out steps ll Ill IV and V it will be necessary to use the PPE stated in the section on PPE in this document for work with live parts Any work carried out which implies a modification of the original electrical settings must be proposed to and accepted by INGETEAM Safety measures Accessing the housing through any other cubicle other than that described is strictly prohibited 4 4 3 Personal Protective Equipment PPE The preventive maintenance tasks for the electrical panels involve Inspection Con trol and Handling actions depending on the case Inspection The use of safety footwear to standard EN 345 1 1992 is mandatory The use of kid leather type gloves is also mandatory Control The use of safety footwear to standard EN 345 1 1992 is mandatory The use of kid leather type gloves is also mandatory Handling The use of safety footwear to standard EN 345 1 1992 is mandatory The use of kid leather type gloves is also mandatory It is also mandatory to use dielectric gloves meeting standard EN 60903 1992 and protective face mask against electric shock complying with EN 168 1994 for voltage testing tasks and opening or closing automatic switches under load AA
52. onnecting cables must be of the appropriate section for the maximum current Special care must be taken to ensure that there are no external elements near the air inlets and outlets to obstruct proper ventilation of the unit 4 Page 24 of 64 AAY 2000IKI 3 Rex _ Date March 2011 f ed Installation Manual INGECON SUN SMART TL AAY 2000IKI03 5 2 Fixing the unit to the wall INGECON SUN SMART TL units have a system for anchoring to the wall To guarantee good heat evacuation and promote sealing the units must be placed on a perfectly vertical wall or failing this with a slight slope of a maximum of 10 o 80 with respect to the vertical but never forwards Never place the inverter on its side or with the connectors facing upwards AAY2000IKI03 Page 25 of 64 po Rev _ f Date March 2011 j iy NO Installation Manual tem INGECON SUN SMART TL inge AAY2000IKI03 A solid wall must be reserved for fixing the inverter Bear in mind that it must be possible to drill the wall and fit suitable wall plugs and bolts to support the unit s weight A fixing plate is supplied with the unit This plate must be fixed to the wall on which the unit is subsequently to be fitted Follow these steps for fixing to the wall Mark the attachment points for the plate on the wall Drill holes in the wall with a bit recommended for the screws to be used to secure the plate to the wall later Fix the plate usi
53. oth hands on the top and bottom 2 Follow the necessary ergonomic advice for lifting weights The unit weighs between 60 and 65 kg depending on its power 3 Do not release the unit until it is perfectly secured or placed 4 Ask someone else to guide the movements to be made K 24 Wr AAY2000IKI03 Page 17 of 64 po Rev _ f Date March 2011 4 Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 The unit has two lifting eyes on top to allow it to be lifted by a crane These eyes may be removed once the unit has been installed The unit has two feet on the bottom to avoid damage to the connectors when placed on a horizontal surface These feet may be removed if desired once the unit is fixed to a vertical surface 3 4 Storage If the unit is not installed immediately after receipt the following points should be taken into account in order to prevent damage The package must be stored in the position in which the box arrived Keep the unit free of dirt dust shavings grease etc and away from rodents Keep away from water splashes welding sparks etc Cover the unit with a breathable protective material in order to prevent condensation due to ambient humidity Neither units stored at the manufacturing plant or in the client s facilities must be subjected to climate conditions other than those indicated in the Section Environmental characteristics It is very important to protect the
54. rch 2011 HN pr A v Ax Mer Paper M N Installation Manual INGECON SUN SMART TL AAY2000IKI03 ingeteam 11 Specifications Sun 12 5TL Input Values DC Power Range Recommended PV 11 4 12 9 kWp 14 25 16 25 kWp 17 1 19 5 kWp 18 9 21 kWp array MPP voltage range 155 450V 145 450V 160 450 V 190 450 V Maximum DC voltage 125 550 V 125 550 V 125 550 V9 125 550 V Maximum DC Current 22A 33 A 33A 33A No of DC inputs 12 12 12 12 MPPT 3 3 3 3 Output values AC Rated AC power in HT mode 10 kW 12 5 kW 15 kW 16 2 kW Maximum AC power in HP mode 11 kW 13 8 kW 16 5 kW 18 kW Maximum AC Current 17A 24 2 A 25 5 A 26 2 A Rated AC voltage 400V 400V 400V 400V Rated AC frequency 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz Phi Cosine 1 1 1 1 Adjustment of Cosine Phi 0 9 at Phom 0 9 at Pnom 0 9 at Phom 0 9 at Phom THD lt 3 lt 3 lt 3 lt 3 Ventilation airflow Inlet fans 3x 78 m h 3x 78 m h 3x 78 m h 3x 78 m h Outlet fans 3x 78 m h 3x 78 m h 3x 78 m h 3x 78 m h General Information Standby energy consumption 30W 30W 30W 30W Energy consumption at night OW OW OW OW Operating temperature 20 C to 70 C 20 C to 70 C 20 C to 70 C 20 C to 70 C Relative Humidity 0 95 0 95 0 95 0 95 Protection class IP 65 IP 65 IP 65 IP 65 Normative references VDE0126 1 1 EN 50178 RD 661 2007 RTC alle rete BT di Enel Distribuzione
55. s appearance is as follows While this screen is displayed the internal actions which SAM OIE take place are ESPA A RD1663 gt gt gt Sending of a configuration change command to the DSP gt gt gt DEUTSCHLAND VDE0126 1 1 Request for reading of configuration Awaiting Configuration response L TE Once configuration has been completed to 100 the following screen will appear NTRY NORMATIVE The unit must be restarted for the new configuration to be oom Do operational To do this open the DC isolating switch and ESPA A RDI663 wait 5 seconds after the display goes dark The unit will gt gt gt DEUTSCHLAND VDE0126 1 1 be reinitialised when switched back on Prozess beendet OK ES Page 48 of 64 AAY20001KI 3 Rev _ Date March 2011 y EL 4 Y d Installation Manual INGECON SUN SMART TL AAY2000IKI03 ingeteam To complete the configuration change the unit must be marked appropriately There is a space on the ratings plate on which to mark some of the standards with which the unit complies because this is the way the authorities which demand compliance require it The standards which it is obligatory to mark are INGETEAM ENERGY S A Ingeteam e deis 13 Biens Sariguren Navarre VDEO0126 1 1 for changes to configuration for GERMANY and INGECON SUN SMART FRANCE AA RTC alle rete BT Enel Distribuzione CEI 11 20 2000 CEI 11
56. s characteristics the country in which it is located or other special conditions which may apply In any case before starting up it is necessary to ensure that the installation complies with the applicable legislation and regulations and that at least the part to be started up is complete 6 1 1 Inspection Before inverter start up a general inspection of the units must be carried out involving mainly Check that the cables are correctly connected to their connectors at the bottom of the housing Check also that these cables are in a good condition and that there are no hazards in their environment which damage them such as sources of intense heat objects which could cut them or arrangements which put them at risk of impacts or pulls Removing the perspex type protections for performing this inspection is strictly forbidden If you have chosen to incorporate DC or AC arresters check that they are correctly installed in their bases and that the status window is not red see Kits and accessories Check that the unit is firmly fixed and there is no danger of it falling off Check that the isolating switch is in the ON position 6 1 2 Sealing of the unit During installation make sure that the protection grade of the equipment has not been altered In all connections through cable glands give cabling enough length inside the unit so it does not pull on the internal electrical connection terminals Ensure that the cutouts
57. s that communication has been lost This may be due to problems with the communications cable if the communications installation is fixed or because the inverter is resetting in which case the flashing will be momentary If the flashing is not accompanied by this message on the display the problem is that the external fan is not working correctly Check that no foreign bodies have entered the fan preventing it turning Ensure that an adequate flow of air arrives 8 1 2 2 1 second flashing The internal fan is not working correctly Contact Ingeteam Energy S A AAY2000IKI03 Page 41 of 64 Rev Date March 2011 Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 8 1 2 3 3 second flashing The inverter is in self limiting mode because it has reached the maximum permissible temperature In this situation check that the fans are running that the air inlets and vents are free from obstacles and that there are no sources of intense heat near the inverter If the problem persists contact Ingeteam Energy S A 8 1 2 4 Steady light This LED indicates that an alarm has occurred in the inverter Shown below are some of the alarms which can indicate problems in the inverter which can be checked and or resolved 0400H Manual stop The unit has been stopped manually Check that the manual stop is not activated If it is release it from the display 0001H Vin out of range 0002H Grid frequency out of range 0004H
58. tatus Fmin When it is evaluating the lower limit for frequency protection Status Completed When the AUTOTEST is complete The AUTOTEST process can be interrupted at any time by selecting the STOP AUTOTEST option which appears in place of START AUTOTEST while it is being carried out Once an autotest has been completed the results can be displayed by selecting RESULT The results are accessed by pressing OK and you move between the four available screens of results such as the screens shown below as example results screens for Vmax and Fmax 12 04 10 AUTOTEST Phase 2 Result Vmax Vmax 238 V Vac 236 V Time 070 ms AAY2000IKI03 Rev _ Date March 2011 12 04 10 AUTOTEST Phase 2 Stop Autotest Result Status Vmax 12 04 10 AUTOTEST Phase 2 Result Fmax Fmax 50 02 Hz Fac 49 99 Hz Time 060 ms Page 53 of 64 Installation Manual Rea INGECON SUN SMART TL inge AAY20001KI03 10 Kits and Accessories The following describes the various accessories that can be installed on units Commu nications kits DC discon nect kit m a E m me m s F m m x iE A A EEG m NUNG SH Ee 5 NE EN NEED NN TOC pum M E _ E pa aa 2 AA a DC arrester kit AC arrester kit if Page 54 of 64 AAY20001KI 3 Rey Date March 2011 y if 4 4 pe eh 7 Y Installation Manual INGECON SUN SMART TL AAY2000IKI03 ingete
59. ten ing torque 1 2 Nm 5 Tighten the screw Tightening torque for cables from 13 to 20 mm 6 8 Nm If the inverter and the grid connection point are far enough apart to require the use of cables of a greater section AAY2000IKI03 Page 33 of 64 Rev Date March 2011 Installation Manual lemm INGECON SUN SMART TL inge AAY20001KI03 an external junction box close to the inverter to make this section change is recommended 5 3 6 1 Protection of the connection to the Electricity Grid It is necessary to install protection elements in the connection between the inverter and the Electricity Grid Thermomagnetic circuit breaker A thermomagnetic circuit breaker and or fuse needs to be installed in the connection from the inverter to the Elec tricity Grid The following table provides the necessary data for the selection of these devices by the installer All data in Am peres Ingecon Sun Maximum inverter Nominal current current of type gL ther momagnetic fuse Type B When selecting the protection in an installation it must be borne in mind that its circuit breaking capacity needs to be higher than the grid connection point s short circuit current It must be taken into account for correct selection of the protection that the ambient working temperature influences the maximum current permitted by these protections as indicated by the manufacturer Differential switch Never install in the grid connection for SMART TL uni
60. th tools which prevent damage to the packaging The unit must be protected during transport and storage from mechanical knocks vibrations water splashes rain and any other product or situation which may damage it or alter its behaviour Transport must be carried out using a pallet truck forklift truck or crane whenever possible Transport using a pallet truck At least the following requirements should be observed 1 Place the packaged unit centred with respect to the forks 2 Try to locate it as close as possible to the connection between the forks and the steering unit 3 In any case observe the instructions in the pallet truck s user manual Transport using a forklift truck At least the following requirements should be observed 1 Place the packaged unit centred with respect to the forks 2 Try to locate it as close as possible to the connection between the forks and the chassis 3 Ensure that the forks are perfectly level to avoid overturning the unit 4 In any case observe the instructions in the forklift truck s user manual Transporting the unpacked unit Once the unit has been transported to the place where it is to be located and only when it is to be installed unpack the unit At this time it can be transported vertically over a short distance without packaging The following guidelines must be observed At least the following requirements should be observed 1 Hold the unit between two people using b
61. the risk Adequate lighting Work with care Keep sufficient distance to prevent contact with the part causing the risk control rod in the isolating switch door Knocks punctures and cuts from objects and or tools Keep the lid closed if not working inside Adequate lighting Order and cleanliness Mandatory use of hard hat safety footwear and gloves when necessary Flying particles fan Recommended use of anti impact glasses when accessing the fan inlet and outlet zones Electrical risk Comply with that laid down in the PPE section and in the general safety standards Inform the worker of the risk Comply with that laid down in the legislation applicable to the installation in which the unit is lo cated both that for the type of installation and the country where it is located itself 4 4 2 Additional risks and measures in handling tasks Thermal Contact Inform workers of the risk Recommended use of gloves Disconnect the power and wait 10 minutes for the hot parts inside the unit internal radiator to cool To carry out handling on the unit the voltage must be disconnected To disconnect the voltage it is necessary to d Page 22 of 64 AAY2000IKI 3 Rev _ Date March 2011 f ed Installation Manual INGECON SUN SMART TL AAY 2000IKI03 I Stop the unit Il Disconnect the PV DC power cable isolate it sign it and protect it Ill Disconnect the grid AC power cable IV Wait 10 mi
62. tion For the following check take careful note of the following warning There are electrical capacitances in the unit which can maintain high voltages even after having disconnected the inverter from the solar panels and the grid Always wait 10 minutes after disconnection before opening the inverter L Page 42 of 64 AAY 2000IK1037 Rex _ Date March 2011 Installation Manual INGECON SUN SMART TL AAY 2000IKI03 Procedure to determine what has caused the insulation fault 1 Disconnect the solar panel circuit from the inverter ingetearn 2 Open the inverter taking the safety warnings in this section into account and treating the operation as handling with which that laid down for handling operations in the Section Safety Instructions will apply 3 Three varistors are fitted to each of the three power cards Remove the varistors 4 Check with a multimeter that there is high impedance in the varistor terminals and continuity at the thermal fuse terminals or each card If this is not the case the varistor or thermal fuse which does not pass the check above will need to be replaced 1 3 fuse 5 If the problem persists and the check is correct contact Ingeteam Energy S A 6 Fit the three varistors in their correct position on the each card before closing the unit 8 1 3 Red LED This is the continuously lit LED indicating that the inverter is manually stopped To start it up this must be
63. tly The units are cooled by forced convection using six fans three inlet and three outlet each capable of handling a flow of 78 m h if T r Y t AAY2000IKI03 Page 13 of 64 po Rev _ f Date March 2011 i P Installation Manual fea INGECON SUN SMART TL inge AAY20001KI03 In all cases there must be an unobstructed flow of air through the grills on the side of the unit 2 2 Environmental characteristics The environmental conditions for operation are Minimum temperature 20 C Minimum surrounding air temperature 20 C e Maximum surrounding air temperature 70 C Maximum humidity without condensation 95 2 3 EMC requirements The INGECON SUN LITE TL System is equipped with the necessary filtering elements to comply with EMC re quirements for industrial applications in order to prevent disturbances in other equipment outside the installation ES t7 Page 14 of 64 AAY2000IKI 3 Rex M Date March 2011 f 4 7 L Installation Manual INGECON SUN SMART TL AAY20001KI03 ingeteum 3 Operating conservation and transport conditions 3 1 Safety warning Failure to follow the instructions provided in this section may lead to damage to the equipment Ingeteam Energy S A accepts no liability for damage resulting from the failure to follow these instructions 3 2 Receipt and unpacking of the unit Reception Upon receipt of the shipment check the terms specified in
64. ts without a transformer a differential switch with a limit cur rent below the maximum fault current which may occur in the PV installation under all its operating conditions The ground capacitance of the PV modules varies depending on the manufacturing technology e g thin layer modules with cells on metal support The PV modules used with the INGECON SUN SMART TL unit must have a coupling capacitance of less than 50 nF kWp During feeding to the grid a shunt current is produced from the cells to ground the value of which depends on the type of module assembly and also varies with atmospheric conditions rain snow This service conditioned shunt current must not exceed the breaking current value of the differential switch If it does so the connection of the inverter to the grid may trip the differential switch external to the inverter The unit will need to be started up manually as the ON OFF status is conserved even though the apparatus is disconnected The section on Display control explains how to connect it ES Page 34 of 64 AAY2000IKI 3 Rev _ Date March 20 11 4 4 f pott L Installation Manual INGECON SUN SMART TL AAY20001K103 ingeteam 5 3 7 Connection to the PV array The INGECON SUN SMART TL family of inverters works with 3 independent PV arrays and each one has an ad vanced maximum power point tracking MPPT system to extract the maximum energy from each PV array This means that the unit
65. unit from chemical products which can cause corrosion as well as from salty atmospheres 3 5 Conservation In order to permit correct conservation of the units they must not be removed from their original packaging until it is time to install them In case of prolonged storage the use of dry places avoiding as far as possible sharp changes in temperature is recommended Damage to the packaging cuts holes etc prevents the units from being kept in optimum conditions before instal lation INGETEAM ENERGY S A accepts no liability in the case of failing to observe this condition 3 6 Waste handling During the various processes for installation start up and maintenance waste is generated which must be handled appropriately according to the regulations in the corresponding country At the end of the unit s life the waste must be processed by an authorised waste management company Ingeteam Energy S A in accordance with its policy of respect for the environment will inform the authorised manager via this Section of the location of components to be decontaminated ES Page 18 of 64 AAY2000IKI 3 Rev _ Date March 2011 4 4 f pott L Installation Manual INGECON SUN SMART TL AAY 2000IKI03 The elements within the unit that must be handled individually are 1 Electrolytic condensers or condensers containing PCB 2 Batteries and accumulators 3 Printed circuit cards 4 Liquid crystal displays Their locat
66. which the original unit was certified In this case the certificates prior to the change will be invalid INGETEAM ENERGY SA accepts no liability for any type of problem caused by changing these limits ES Page 50 of 64 AAY20001KI 3 Rey M Date March 2011 f 7 A Installation Manual INGECON SUN SMART TL AAY 2000IKI03 9 6 Language Pressing once the MONITORING menu has been selected accesses this 12 00 12 04 10 MAIN MENU Monitoring Configuration Change date The language can be changed from this menu Select the desired language using the and keys Pressing OK when the cursor is positioned over the desired language selects it The display shows the following message Pressing OK again confirms the selected language and the MAIN MENU appears now changed to the selected language 9 7 Change date From this menu you can change the date and time The internal clock automatically changes the time from summer to winter and vice versa Each time OK is pressed the data blinks in the top part of the display where it is shown to be operating in the following order hours minutes day month and year The part of the date or time which it is desired to modify is changed using the LA and keys The new date and time is stored by pressing OK when the year is blinking The display shows the following message
Download Pdf Manuals
Related Search
Related Contents
Manual de instrucciones SANDWICHERA Cypress CY7C185 User's Manual Betriebsanleitung FST CDE-T Ableiter 仕様書 IBUKI 取扱説明書 Sony XM SD22X User's Manual Sharp LC-40LE361EN-BK 40" Full HD Wi-Fi Black LED TV MC92N0-G Series Regualtory Guide [English] (P/N 72-161752 none 18102 Installation Guide Copyright © All rights reserved.
Failed to retrieve file