9560 User Manual - English

image

Contents

1. heat Does not have separate wire for emergency heat jump W2 amp TTT 9560 WIRING SAMPLE 4 Typical heat pump with cool active reversing valve auxiliary emergency heat and second stage of cooling System fault indicator connected L terminal BESHE 110 1033 En qxd 5 13 03 pe PM Page 6 TERMINAL LEGEND 9560 Black EQUIPMENT TO CONNECT REQ TERMINAL FUNCTION 24VAC common connection System fault indicator connection Yes For input of 24VAC common side of transformer For input of system fault indicator if present 24VAC hot connection For input of 24VAC hot side of transformer Second stage cooling connection First stage compressor connection Energizes on a call for second stage cooling Energizes on a call for first stage heating or cooling Emergency heat connection Energizes on a call for heat in the EM mode only Indoor fan connection Energizes with Y1 2 and W2 terminals or with FAN option switched to the ON position Second stage heat connection Energizes on a call for second stage heating auxiliary heat Cool active reversing valve connection Energizes when in the in COOL mode Heat active reversing valve connection Energizes when in the HEAT or EM modes For systems using a backup heat source If separate terminal connection is not available jumper E
2. Soe PAULA 555 Ord weg iN Eg o 6 RESET J ORO Q NO NORMAL LO LO A it EMER HEAT Figure 4 7 If mounting on drywall tap plastic anchors into wall NOTE ENCLOSED PLASTIC ANCHORS DO NOT REQUIRE A DRILLED HOLE FOR DRYWALL 8 Drill the marked holes using a 3 16 drill bit if mounting on a sur face other than drywall 9 Align base with plastic anchors and feed wires through opening 10 Secure base to wall with supplied screws NOTE THE THERMOSTAT WILL MOUNT HORIZONTALLY ON A SINGLE GANG JUNCTION BOX 11 Strip end of wires 5 16 if needed _ 110 1033 En qxd 5 13 03 3505 Page 5 Black plate 12 Terminal screws are already loose and ready for wire insertion Insert wires into terminal strip Figure 5 matching the label to the corresponding terminal see Wiring Diagrams below Tighten screws 13 Make sure wire connections are secure 14 Push access wire back through opening J LA 0 0 0 0 0 0 cACM D9 aooaa Figure 5 Wiring Diagrams for 9560 9560 WIRING SAMPLE 1 Typical heat pump with cool active reversing valve and auxiliary emergency heat 9560 WIRING SAMPLE 2 Typical heat pump with heat active reversing valve and auxiliary emergency heat 9560 WIRING SAMPLE 3 Typical heat pump with heat active reversing valve and
3. the buttons Press either the or button to change the display 2 After three seconds the display will switch to the differential settings The display will read DIFFERENTIAL 1 3 The temperature differential is factory set at 1 F 0 5 C for the first stage Press either the button to adjust the 1 stage differential between 0 5 F 3 F 4 Either wait three seconds or press the lt button The display will indicate DIFFERENTIAL 2 5 The 2nd stage differential is factory set at 2 F 1 5 C Press either the or button to adjust the 2nd stage temperature differential between 1 F 6 F 1 C 3 C 6 Press the or button to adjust the 2nd stage timed differential between 5 to 40 minutes Either wait 5 seconds or press the amp button 7 Either wait three seconds or press the lt button The display will indicate AUTOCHANGE DEADBAND 8 Press either the or button to adjust the deadband between 2 F 8 F 1 0 4 5 C 9 Either wait three seconds or press the button The fan icon and ON will be displayed 10 Press either the or button to adjust the residual cool fan delay between 0 30 60 or 90 seconds 11 The display will return to the original room temperature display after a few seconds LED Indicators The Robertshaw 9560 uses three LED indicators in addition to icons on the LCD display to indicate functionality of the thermostat When illumi n
4. F Celsius C proper room temperature settings see Changing Fahrenheit F to Celsius C section Er on display If error occurs after turning on EMERGENCY HEAT make sure the system switch is in HEAT also If Er is still on display call technical service If problems with thermostat cannot be resolved call Technical Support 800 445 8299 Monday Friday 7 30 AM 5 30 PM CST 11 Memm o 110 1033 En qxd 5 13 03 p PM Page 12 Two Year Limited Warranty Climate Controls Americas warrants to the original contractor installer or to the original consumer user each new Robertshaw thermo stat to be free from defects in materials and workmanship under normal use and service for a period of two 2 years from date of purchase This warranty and our liability does not apply to batteries or merchandise that has been damaged by misuse neglect mishandling alterations improper installation or use in a way other than in accordance with Climate Controls Americas recommendations and instructions Climate Controls Americas agrees to repair or replace at its option any thermostat under warranty provided it is returned within the warranty period postage prepaid with proof of the date of purchase Cost of thermostat removal or reinstallation is not the responsibility of Climate Controls Americas Repair or replacement as provided under this warranty is the exclusive remedy of the consumer Climate Controls America
5. and W2 Most heat pump systems will have a cool active OR heat active reversing valve Use the appropriate terminal Jo org U g sa ol IC ai OIG RESET J OKO OKO NORMAL o ge EMER HEAT Figure 6 15 A temperature limiting jumper has been included in this thermo stat Cutting this jumper J3 limits the heating setpoint to no greater than 72 F and the cooling setpoint to no lower than 78 F Figure 7 es 16 Replace thermostat cover by snapping into place 110 1033 En qxd 5 13 03 pe PM Page 7 Black Cut the J3 jumper to enable temperature limiting RAINS 5 org Ua OFS O Jo k 089 ORO NORMAL EMER HEAT Figure 7 17 Turn on power to system Test thermostat as described in the following section Step 3 Testing the Thermostat A WARNING DO NOT SHORT JUMPER ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPER ATION THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY CAUTION DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE
6. into the AUTO position The blower fan should turn off AUTO 2 amp gt Memm o 110 1033 En qxd 5 13 03 g PM Page 9 Black Step 4 Customizing the Thermostat Settings System Cool The thermostat controls the cooling Off The heating and cooling systems are off Heat The thermostat controls the heat AUTO The thermostat automatically selects heat or cool depending on the temperature Fan Auto Equipment controls the fan On The fan operates continuously Temperature The default setpoint temperature for heating is 70 F 21 C for cool ing is 78 F 25 C and for auto is 72 F 22 C After putting the sys tem switch in heat cool or auto press either the or button to adjust the temperature setting up or down The display will return to the current room temperature five seconds after the last input and the new setpoint will be saved AUX CHECK EMER Figure 8 Temperature Differential and Deadband The temperature differential is factory set at 1 F 0 5 C for the 157 stage differential and 2 F 1 0 C for the 2 stage This means that whenever the room temperature changes by one degree Fahrenheit from the tem perature setting the system will turn on If the system turns on too often increase the temperature differential The 2 stage will turn on when the room temperature changes from the desired temperature by the sum of the 1 an
7. r All wiring must conform to local and national building and electrical codes and ordinances Do not short jumper across terminals on the gas valve or at the system control to test installation This will damage the thermostat and void the warranty Step 1 Replacing Existing Thermostat 2 Remove cover from 1 Turn off power to heating and cooling system d thermostat to expose wires Figure 1 Figure 1 3 Disconnect wires one at a time from existing terminals Use enclosed labels to mark existing wires Refer to cross references in Table 1 if existing wiring does not directly match the labels Old Terminal New Label Description L L System Check R V VR or VR R R 24 VAC Return Y Y1 or M Y1 1st Stage Cooling Control OorR 0 Cool Active Reversing Valve B Heat Active Reversing Valve ForG G Fan Control Relay Y2 Y2 2nd Stage Cooling Control W2 or W U W2 2nd Stage Heating Control C XorB 24 VAC Transformer Common Side W1 or W E Emergency Heating Relay NOTE THIS THERMOSTAT REQUIRES A 24V COMMON WIRE FOR PROPER OPERATION Table 1 2 110 1033 En qxd 5 13 03 pe PM Page 3 Black i If you have any questions about cross referencing the old terminal to the new label reference your equipment installation manual a licensed contractor or call Robertshaw Technical Support at 800 445 8299 4 Remove existing thermostat base from
8. wall Recycling Thermostat If this thermostat is replacing a thermostat that contains mercury in a sealed tube do not place your old thermostat in the garbage Contact your local waste management authority for instructions regarding proper disposal of the thermostat If you have any ques tions call Robertshaw technical support at 1 800 445 8299 Step 2 Installing Model 9560 Thermostat NOTE FOR NEW INSTALLATIONS MOUNT THERMOSTAT ON INSIDE WALL FIVE FEET ABOVE THE FLOOR DO NOT INSTALL BEHIND A DOOR IN A CORNER NEAR AIR VENTS IN DIRECT SUNLIGHT OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES INSTALLATION AT THESE LOCATIONS WILL AFFECT THERMOSTAT OPERATION 1 Turn power off to the heating and cooling systems 2 Place AUTO HEAT OFF COOL in OFF position Figure 2 3 Place 4 ON AUTO switch into AUTO position Figure 2 ALR AUX CHECK EMER Figure 2 en 110 1033 En qxd 5 13 03 g PM Page 4 Black 4 Remove the cover using a coin or screwdriver Figure 3 Set aside Figure 3 5 Place thermostat against the wall at desired location Make sure wires will feed through opening Figure 4 on base of thermostat 6 Mark placement of mounting holes Figure 4 Set base aside Mounting Holes
9. 110 1033 En gxd 5 13 03 oe PM Page 1 Black ila DELUXE 9 5 NON PROGRAMMABLE THERMOSTAT HEAT PUMP 2 Heat 2 Cool with Auto Changeover User s Manual m l Installation 110 1033 Application The Robertshaw 9560 is a multi stage auto changeover thermostat designed to control 24 VAC heat pump systems up to 2 stage heat and 2 stage cool The 9560 requires the use of a common wire Features e Multi stage control e Auto changeover deadband adjustable from 2 F to 8 F 1 0 C 4 5 C Large back lit display e Adjustable 1 and 2 stage temperature differential Compressor short cycle protection Adjustable fan delay on cooling LED indication of system status Zone system compatible as a master thermostat Battery free EEPROM memory retention Optional temperature limiting settings e Fahrenheit Celsius display option Adjustable from 45 F to 90 F 7 C 32 C Quick wire terminal block 110 1033 En qxd 5 13 03 oe PM Page 2 AX IMPORTANT SAFETY INFORMATION WARNING Black Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing removing cleaning or servicing thermostat Read all the information in this manual before installing or program ming this thermostat This is a 24 VAC low voltage thermostat Do not install on voltages higher than 30 VAC
10. IS BELOW 50 F 10 C THIS CAN DAMAGE THE AIR CONDITION ING SYSTEM AND CAUSE PERSONAL INJURY 1 Place the AUTO HEAT OFF COOL switch into the COOL position 2 Press the button until the temperature setting M HEAT is at least 3 degrees below the room temperature OFF COOL The air conditioning system should turn on within a few seconds NOTE ONCE THE THERMOSTAT TURNS OFF WHEN IN THE COOL MODE A BUILT IN 5 DELAY PREVENTS THE SYSTEM FROM TURN ING ON AGAIN THIS PROTECTS THE COMPRESSOR NO ADDI TIONAL TIME DELAY RELAY IS REQUIRED TO OVERRIDE THE 5 MINUTE DELAY FOR INSTALLATION PRESS THE RESET BUTTON es 110 1033 En qxd 5 13 03 pe PM Page 8 Black i 3 Put the AUTO HEAT OFF COOL switch into the OFF position The air conditioning system ne should turn off 4 Put the AUTO HEAT OFF COOL switch into the HEAT position HEAT 5 Press the button until the temperature setting is at least 3 degrees above room temperature The heating system should turn on The fan may not turn on immediately depending the fan delay built into the furnace 6 Put the AUTO HEAT OFF COOL switch into the OFF position The heating system should turn off The fan may continue to run for a AUTO HEAT short period of time 7 Put the ON AUTO switch into the ON position The blower fan should turn on AUTO e W 8 Put the 4 ON AUTO switch
11. ated the right red LED indicates that the thermostat is calling for emer gency heat The left green LED indicates a call for auxiliary cool When the middle amber LED is illuminated the system is not functioning Call your local HVACR service contractor 10 Memm 110 1033 En qxd 5 13 03 ps PM Page 11 Black Backlit Display This thermostat is equipped with a backlight to make nighttime tempera ture adjustments quick and easy Press the button to activate the backlight The backlight will turn off after about 15 seconds of inactivity Emergency Heat The Emergency Heat switch is located on the bottom right corner To activate emergency heat slide switch from NORMAL to EMER HEAT Reset To reset the thermostat to factory preprogrammed conditions press the RESET button located beneath the lower left corner of the display aE PENIN z LJ S ezo CO yee N HEAT RESET Switch Step 5 Troubleshooting Symptom Remedy Thermostat does not turn on system Check wiring see Installation section Thermostat turns system on and Increase temperature differential off too frequently see Changing the Temperature Differential section CHECK LED is lighted Monitors system status Call your local HVAC service provider Thermostat does not display Check Fahrenheit
12. d 2 stage differential set tings The 2 stage will also turn on if the temperature has not increased or decreased in the event of cooling for a period of twenty minutes Although programmed at the same time as the temperature differentials the deadband is used only during the AUTO mode In the AUTO mode the thermostat will automatically cycle either the heating or cooling system to maintain optimal comfort The deadband is the minimum allowable tem perature which must occur to switch to the opposite mode For example if the deadband is set at 3 F and the setpoint is set at 70 F the thermostat will switch to cooling mode when the temperature reaches 73 F NOTE IF THE TEMPERATURE LIMITING JUMPER J3 IS CUT FIGURE 7 THE DEADBAND IS NOT ADJUSTABLE AND IS AUTOMATICALLY SET TO 6 F 3 C 9 110 1033 En qxd 5 13 03 10 Black Changing Fahrenheit to Celsius Temperature Differential Deadband and Residual Cool The temperature differential is factory set at 1 F 0 5 C for the 1 stage differential and 2 F 1 0 C for the 2 stage The deadband for auto changeover is set at 3 F 1 5 C To change settings 1 The thermostat is preset to display the temperature in degrees Fahrenheit U S models or degrees Celsius Canadian models The temperature display can be changed Press and hold both the or A buttons for three seconds The display will read F or C Release
13. s shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product or under any other theory of liability Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose on this product is limited to the duration of this warranty Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For warranty returns send thermostat shipping prepaid to Climate Controls Americas Warranty Claims Department 515 S Promenade Corona CA 91719 Climate Controls Americas 191 E North Avenue Carol Stream Illinois 60188 United States of America 2003 Climate Controls Americas 110 1033 12 en Black