1. position Wait one minute and repeat step 3 Do not continuously hold down the control knob as you may cause a build up of gas 6 Once the pilot is lit hold down the control dial for at least 10 seconds until the main burner lights Operate the fire between the high and low flame settings as required 7 If the pilot and main burner do not stay lit on releasing the control knob turn the control knob to the ignition position and repeat steps 3 to 4 8 The is a pilot setting only 1 Turn the control knob to position 2 Turn off the gas at the cylinder regulator valve The pilot light will remain alight until the cylinder regulator is turned off 3 Disconnect the regulator from the cylinder when the heater is not in use 4 Remember to remove battery during periods of non use to prevent battery leak Read all of the instruction Manual before using this appliance This appliance must be installed in accordance with such regulations as are in force Installation to be carried out by a competent person The guard glass door on this appliance is to prevent risk of fire or injury from burns and no part of it should be permanently removed IT DOES NOT GIVE FULL PROTECTION FOR YOUNG CHILDREN OR THE INFIRM For the full protection of young children or the infirm we recommend a fireguard conforming to BS 8423 be fitted MANHATTAN 3kw Portable Gas Fire User Manual manufactured by Attempt to use the heater in high rise flats basement
2. Dear Customer We tried to achieve two targets when developing this product The first was to produce the best quality heater on the market The second was to produce the most cost effective heater We feel that we have achieved these two objectives however we would be delighted to hear from you if you have any comments Thank you for purchasing one of the products in our range We wish you many enjoyable warm hours Yours Sincerely S bE Chairman The Manhattan gas stove is made by Universal Innovations It is made to an exacting quality standard and is covered by the following guarantee THIS PRODUCT IS FULLY GUARANTEED FOR 2 YEARS REGARDING PROPER USE This guarantee does not affect your statutory rights in any way HELPLINE Dublin Ireland 00 353 1 2873797 or at www uigroup ie IF YOU NEED ANY ASSISTANCE PLEASE DO NOT HESITATE TO CONTACT US DIRECTLY AT THE FACTORY DO NOT BRING GOODS BACK TO PLACE OF PURCHASE When lighting for the first time burn outdoors for 4 hours minimum to cure the synthetic coals The coals give off an odour when curing The appliance must be installed amp used in accordance with the regulations which are currently in force The heater should be positioned on a level surface Only use in a well ventilated area The minimum room size when using this appliance is 64 cubic metres with a minimum ventilation of 80 cm squared area Attach regulator to end of hose and secure with hose clip Note
3. approximately Heat input 3 0kW Gross Gas consumption 215 grams per hour at maximum setting Gas category 3B using butane gas at 28mbar Gas type amp Supply pressure Butane 28mbar Injector size 0 84 mm Regulator type 28 mbar Regulator Outlet pressure 28 mbar Cylinder sizes 11 4kg cylinder Eire and 15kg or 7kg cylinder U K Hose BS3212 length 40 cm Destination Countries GB amp IE The product is fully guaranteed for two years regarding proper use This guarantee does not affect your statutory rights For servicing contact your local gas supplier Servicing to be carried out by a qualified competent registered gas engineer before the start of every heating season Call 0800 662 663 to speak to you nearest Calor retailer and to order gas Call 01 450 5000 if calling from ROI s Djy isit calor co uk and click on Order Gas For help on this product and our range of products see our website www uigroup ie or contact the factory direct on our Helpline 00353 1 2873797 Helpline hours are 9am to 5pm Monday to Friday We are located at Universal Innovations Ltd Kilcoole Industrial Estate 0086 Kilcoole Co Wicklow Ireland Fit Glass Panel in place as shown Secure in position with fixings as shown Ignition Button Fit back door onto the brackets as indicated above NOTE When fitting gas regulator to the cylinder ensure that the regulator is in the off position To fit battery unscrew igniti
4. for ease of fitting hose lubricate ribbed nipple of regulator with a soap solution Ensure that the area is free from any unprotected combustible material or substance 1 The changing and connection of LPG cylinders must be undertaken in a flame free atmosphere 2 Attach the regulator to the new cylinder Ensure that the hose is not twisted or damaged in any way 3 Use gas cylinders with a gas capacity of 7 15kgs 4 In order to remove the regulator you must ensure that the regulator is in the off position 1 Inspect the hose assembly If the hose is cut or shows signs of excessive wear or is leaking it must be replaced prior to operation of the heater 2 Ensure the heater is positioned with a minimum clearance above and beside of 0 6 metres from flammable materials both vertically and horizontally D 3 Ensure that the glass panel is closed securely F 1 Fit battery type AA provided into ignition button side up See Fig 1 lt Remove battery during periods of non use to prevent battery leak A 2 Turn on gas supply at gas cylinder regulator Unscrew ignition button 3 Push control knob down and turn the control knob to the d position and to fit battery 1 5V type AA at the same time press sparker button to light the pilot 4 If there is no spark check the battery type AA is correctly fitted the pilot flame can be viewed at the right hand side of the coal bed 5 If pilot does not light turn control dial to
5. mes extinguished during use Ensure that all naked flames are extinguished before fitting a new cylinder Store gas cylinders outdoor above ground level in a safe and secure environment Make sure that the gas supply at the gas cylinder is turned off after use Ensure that servicing of the unit is carried out by a competent person in accordance with the instructions enclosed Allow the unit to cool down for one hour before touching the front or sides Follow any safety instructions supplied with gas cylinders Keep unit well away from glass doors and windows to ensure no possibility of heat build up and damage We recommend servicing once a year or after a prolonged period of non use Ensure that there is no blockage of airflow For example sooting and poor burning can be caused by dirt insects cobwebs blocking the airflow to in the burner Abrasive cleaners are not to be used Clean unit with a damp cloth when fully cooled This unit is designed for use with a 7kg or 15kg UK and 11 4kg gas cylinder Eire Remove the glass panel and place the coals in position as shown above This appliance is designed for indoor use only using Butane gas at a supply pressure of 28 millibar and must be serviced by a fully qualified competent registered gas engineer in accordance with the instructions included Please read all accompanying documentation carefully Overall height 680 millimetres approximately Overall width 375 millimetres
6. on button and place battery in housing Refit ignition button securely place battery side up Stove Back Door Glass Panel Synthetic Coals Flexible Gas Hose amp Regulator Item Description Price euro sterling Glass Panel 39 50 40 50 StoveDoor 39 50 40 50 Flexible Gas Hose 10 85 11 85 Regulator 15 00 18 00 Synthetic Coals 34 50 35 50 Parts orders may be placed by contacting us directly at the factory at 00353 1 2873797 by post at Universal Innovations Kilcoole Industrial Estate Kilcoole Co Wicklow Ireland Or by emailing us at info uigroup ie e Model Name e Serial Number e Kilowatt Rating e Month and Year of Purchase e Name and Location of Retailer e Your Name Address and Contact Number ALTHOUGH EVERY PRECAUTION HAS BEEN TAKEN TO ELIMINATE SHARP EDGES ALWAYS TAKE CARE WHEN HANDLING METAL COMPONENTS
7. s bathrooms or bedrooms Use any other gas except Butane Attempt to clean the heater until it is turned off and fully cooled Use naked flame to detect suspected gas leaks Allow children or pets to play near the heater Twist the flexible gas hose Touch the glass panel or front and sides of the unit while the heater is operating Use in leisure vehicles such as caravans and auto caravans Position the appliance close to walls furniture hangings net curtains bed linen and other inflammable materials as this would result in the risk of fire In the event of a gas leak ie If you smell gas turn off the cylinder valve Disconnect the cylinder take it outdoors and contact a competent service technician Never attempt to light the unit if the hose is loose or damaged in any way Also never attempt to light the unit if you have reason to believe that the unit may be leaking gas In the event of a gas leak turn off the gas supply at the cylinder and have the unit fully checked by a competent person in accordance with the instructions enclosed We recommend servicing at the start of every heating season Should you need to change the gas bottle confirm that the gas supply is turned off at the cylinder and that there are no sources of ignition near before proceeding Place heater on a flat level and solid surface at all times Leak test the unit after long periods of storage Wait for 3 minutes before relighting if the burner flame beco