Home

User manual - Electrokit

image

Contents

1. N NUT VM206 e e USER MANUAL UNIVERSAL TIMER MODULE WITH USB INTERFACE WWW VELLEMANPROJECTS EU Table of contents Description Features and specifications Plugging in your board for the first time Starting the software Timer operation modes Relay output Oc uU A A A U U Description of the timer operation modes Timing sequencer user interface 10 Timer Mode C 1 On Delay relay tume on after delay t C 2 Off Delay relay tums off after delay t C X One Shot a single pulse of length t2 after delay t1 C 4 Repeat Cycle after delay t1 relay turns on for 12 then repeats C amp Repeat Cycle relay tums on for time 11 off for 12 then repeats amp Toggle Mode C 7 Start Stop timer Staircase timer C 9 Trigger at release timer f 10 Programmable timing sequence E Let s get started Description No timer is universal except this one 2 reasons why this timer is truly universal 1 The timer comes with a wide variety of operating modes 2 If the built in modes or delays don t suit your application you can simply tailor them according to your needs using the supplied PC software Features e 10 operating modes toggle mode start stop timer staircase timer trigger at release timer timer with turn on delay timer with turn off delay single shot timer pulse pause timer pause pulse timer custom seq
2. 2 after delay t1 Timing begins on the leading edge of the Start signal When the first set time t1 has elapsed the relay contacts transfer to the ON state The contacts remain in the ON state until the second set time t2 has elapsed or the Reset signal is applied or power is interrupted USER MANUAL VM206 Start Reset Output 4 Repeat cycle after delay t1 relay turns on for t2 then repeats Timing begins on the leading edge of the Start signal A cycle is initiated when the output will be OFF for the first set time t1 then ON for the second set time t2 This cycle will continue until the Reset signal is applied or power is interrupted Start Reset Output 5 Repeat Cycle relay turns on for time t1 off for t2 then repeats Timing begins on the leading edge of the Start signal A cycle is initiated where the output will be ON for the first set time t1 then OFF for the second set time t2 This cycle will continue until the Reset signal is applied or power is interrupted Start Reset Output USER MANUAL VM206 6 Toggle mode When a Start signal is supplied the relay contacts transfer immediately to the ON state When the Start signal turns ON again the relay contacts transfer to the OFF state and on the next Start signal to ON state etc Start Reset Output 7 Start Stop timer When a Start signal is supplied the relay contacts transfer immediately to the ON state and the s
3. et time t1 begins When the settime t1 has elapsed the relay contacts transfer to the OFF state The timer is reset by applying the Start signal before the set time t1 has elapsed Start Reset VENETO ERES NI 5 Output i 8 Staircase timer When a Start signal is supplied the relay contacts transfer immediately to the ON state and the set time t1 begins When the set time t1 has elapsed the relay contacts transfer to the OFF state The timer is reactivated by applying the Start signal before the set time t1 has elapsed Start Reset Output fig 10 USER MANUAL VM206 8 9 Trigger at release timer On the trailing edge of the Start signal the relay contacts transfer to the ON state and the timing begins When the set time t1 has elapsed the relay contacts transfer to the OFF state The timer is reactivated by applying the next trailing edge of the Start signal before the set time t1 has elapsed Start Reset Output fig 11 10 Programmable timing sequence In this mode you can program a sequence of up to 24 timing events You can specify the relay state ON or OFF and the duration of each timing event The programmed sequence can be repeated You can save the timing sequence to file Start Reset Output fig 13 USER MANUAL VM206 Relay state Time fields Timing event list Timing bequencer min sec ms Timing Sequence lum t Delete Timing send lt lt C
4. lay t1 repeat cycle after delay t1 relay turns on for t2 then repeats repeat cycle relay turns on for time t1 off for t2 then repeats toggle mode start stop timer staircase timer trigger at release timer NI RK O 10 programmable timing seguence Now you can setup your first timing program for the VM206 1 select any of the options from 1 to 9 2 enterthe time or use the default 2sec and 1sec 3 now click the Send button USER MANUAL VM206 The VM206 is now programmed You can check the operation by pressing the TST1 Start button The RELAY ON LED indicates the operation You can stop the timer operation by pressing the TST2 Reset button Power supply Heavy duty relay 12 100 mA g For inductive loads X Ski aio CS BAI add optional VDR o e g Velleman VDR300 Velleman Y E 206 E x 8 250 VAC j CEN NO NC ENS PVM206 1 Relay output ARG IN2 GND ub R7RIRZS RAP Start Stop SENEC RITRIT Buffered inputs bs RELAY ON BEEN EE PONER ON contact or Status LEDs U open collector does Het TOE oc 0 We USB PC ny l Oy MDP st L ERE CSP Start Resef connector pushbuttons To get the relay functioning as well you need to connect the 12 V supply to the SK1 screw connector You can disconnect the USB cable and test
5. opy Timing Repeat Sustain the first state until start signal OFF Auto Start amp Repeat Timing sequence user interface Options e timing insert timing e delete timing e copy timing e repeat e sustain the first state until Start signal is OFF e auto start repeat By selecting the option Sustain the relay state of the first timing event is sustained as long as the Start signal is ON or the Start button is kept pressed down Start Reset Susfained a Output USER MANUAL VM206 By selecting the option auto start amp repeat the timing sequence restarts automatically when the power supply is connected or when there has been a power outage Timing Sequencer Timing Sequence ees Inde qe Insert Timing gt r Delete Timing SEDE Timing Repeat Sustain the first state until start signal OFF Mare gt gt fig 16 Normally the relay will be OFF after the last timing event of the seguence The relay can be forced to stay ON by setting the time of the last ON action to zero USER MANUAL VM206 11 vellement IMM A O Nelleman nv Velleman_RnD ORDERCODE VM206 gt 16353110 1485 llo Legen Heiweg 33 Gavere Belgium REVISION HVM206 1 5
6. the timer operation as a stand alone device with the 12 V supply There are two inputs on the board IN1 and IN2 for remote switches or NPN transistors to control the timer operation The switch or transistor connected between IN1 and GND acts as the Start button TST1 and the switch or transistor connected between IN2 and GND acts as the Reset button TST2 Relay output The relay contacts are connected to the SK3 connector e Common e NO Normally Open e NC Normally Closed Space is provided on the board for a transient suppressor option to reduce contact wear Mount VDR1 for sup pression of the NC contact Mount VDR2 for suppression of the NO contact USER MANUAL VM206 5 Description of the timer operation 1 On delay relay turns on after delay t1 Timing begins on the leading edge of the Start signal When the set time t1 has elapsed the relay contacts transfer to the ON state The contacts remain in the ON state until the Reset signal is applied or power is interrupted Start Reset MEME ss lt fig 3 2 Off delay relay turns off after delay t1 When a Start signal is supplied the relay contacts transfer immediately to the ON state Timing begins on the trailing edge of the Start signal When the set time t1 has elapsed the relay contacts transfer to the OFF state The timer is reset by applying the Reset input or by interruption of power 3 One shot a single pulse of length t
7. uence timer e wide timing range e buffered inputs for external START STOP buttons e heavy duty relay e PC software for timer configuration and delay setting Specifications e power supply 12 VDC 100 mA max e relay output 8 A 250 VAC max e minimum event time 100 ms e maximum event time 1000 h over 41 days e dimensions 68 x 56 x 20 mm 2 6 x 2 2 x 0 8 USER MANUAL VM206 Plugging in your board for the first time First you will need to plug your VM206 into an available USB port on your computer so Windows can detect your new device Then download the latest software version for the VM206 on www velleman eu via these simple steps 1 goto http www vellemanprojects eu support downloads code VM206 2 download the VM206 setup zip file 3 unzip the files in a folder on your drive 4 double click the setup exe file An install wizard will guide you through the complete installation procedure Shortcuts to the VM206 software can now be installed Starting the software 1 locate the VM206 software shortcuts programs VM206 2 click on the icon to start the main program 3 then click on the Connect button the Connected label should now be displayed Lonnected send You are now ready to program the VM206 timer Timer operation modes on delay relay turns on after delay t1 off delay relay turns off after delay t1 one shot a single pulse of length t2 after de

Download Pdf Manuals

image

Related Search

Related Contents

Serveur ADONIS 2 et analyse des SUMEHRs en ligne - Trix-Data  MANUALE UTENTE LP 30  Symantec Enterprise Security Manager 6.0 for PC, Unix  Crestron electronic Isys TPS-3000 User's Manual  IQ SmartLogger II Software Manual  Moltiplicatori di Pressione Serie P  Cat. N. 26-C  Belkin 15m 6 UTP  IronKey F200 2GB  ECHO-IRLP Nano-Node SE USER`S MANUAL - Micro-Node  