1. Lr activex forever HEALTHCRAFTSynerPole System nes wwwActiveForever com z Installation Instructions DC100 1 800 377 8033 suite s04 85345 SP S SP HD SPB S SPB HD SPB AK STP S STP AK SP ACP SP ACP AK Sales ActiveForever com SAFETY WARNINGS VAN Please read SuperPole System Introduction carefully prior to proceeding with all product installations Embrace life SUPERPOLE SUPERPOLE BARIATRIC 4 5 SP S SP HD SUPERPOLE with SUPERBAR sssssssssessensnnnnnnnnnnnnnnn 6 7 SPB S SPB HD SPB AK B SUPERPOLE with SUPERTRAPEZE ccsssssssseese 8 9 STP S STP AK ie SUPERPOLE with ANGLED CEILING PLATE 10 11 SP ACP SP ACP Ak me SUPERPOLE SOLUTIONS FOR CEILING CHALLENGES 12 Ceiling Height Challenges For floor to ceiling ranges greater than 8 feet Vly 9 Ceiling Construction Challenges For Angled Ceilings and Large Joist Spacing HealthCraft Products Inc DC100 REV D Page 1 of 12 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 Specifications subject to change without notice THANK YOU Thank you for purchasing the SuperPole System We are confident that you will find the unique design and durable construction of this HealthCraft product to be of great assistance in your daily routine To fully enjoy your SuperPole System please take a few moments to read these instructions You should
2. 12 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 Specifications subject to change without notice SPB S SUPERPOLE WITH SUPERBAR SP P Pole Assembly SPB BX SuperBar Parts Box SP402 Base Plate Assembly SP403 Top Plate Assembly SP404 SuperBar Assembly SP411 Castellated Collar Assembly SP501 SuperBar Parts Pack SP403 Top Plate Assembly SP403HD Top Plate Assembly Heavy Duty SP403HDU Top Plate Assembly Ultra SP P Pole Assembly SP PHD Pole Assembly Heavy Duty SP PU Pole Assembly Ultra SuperBar Parts Pack SuperPole Instructions Brochure FHSCS 8 32x S S Screws x2 Hex Key Wrench 3 32 Hex Key Wrench 5 32 Cone Point Set Screw 5 16 24x x4 SuperBar Assembly SuperBar Weldment Grip 16 long SP402 Base Plate Assembly HealthCraft Products Inc 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 SUPERBAR SP102 Pivot Bushing x2 SP170 Spring Ring SP106 Castellated Collar HARDWARE HW100 Set Screw FHSCS 8 32 x 375 S S wc HW112 Set Screw Cone Point 5 16 24x3 8 w w M HW300 Hex Key 3 32 Short Arm HW320 Hex Key 5 32 Long Arm not to scale DC100 REV D Page 7 of 12 Specifications subject to change without notice SUPERTRAPEZE INSTALLATION INSTRUCTIONS Figure 9 Prior to installing the SuperPole with SuperTrapeze we recommend that you first read through these instructions C1 Complete step A1 to A2 on page 4
3. DC100 SuperPole Instructions MK100 Brochure SP402 Base Plate Assembly HealthCraft Products Inc 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 SP403 HD HDU TOP PLATE ASSEMBLY SP117 Top Rubber HW318 Nylon Washer HW302 Clevis Pin P115 HD HDU Top Plate Heavy Duty Ultra HW323 Cotter Pin SP P HD HDU POLE ASSEMBLY SP400 Pole with Grip P113 HD HDU Pole Heavy Duty Ultra GR101 Grip 20 Length SP114 Plastic Cover Sleeve SP105 Threaded Collar SP105HD Threaded Collar Heavy Duty SP105HDU Threaded Collar Ultra SP172 Jam Nut SP107 Extension Screw SP145 Plastic Washer SP402 BASE PLATE ASSEMBLY SP112 Base Plate SP118 Base Plate Rubber DC100 REV D Page 5 of 12 Specifications subject to change without notice SUPERBAR INSTALLATION INSTRUCTIONS Figure 5 Prior to installing the SuperPole with SuperBar we recommend that you first read through these instructions B1 Complete steps A1 to A3 on page 4 and then continue with step B2 B2 Remove the cover sleeve 6 from the pole assembly 2 B3 Unpack the contents of the SuperBar parts box B4 Using the small hex key wrench 11 and a countersunk screw 12 attach one white plastic pivot bushing 13 to the T bar assembly as shown in Figure 5 Set aside the other plastic pivot bushing and screw B5 Slide the spring collar 17 upwards on the castellated collar 14 assembly to ga
4. and then continue with step C2 C2 Unpack the contents of the SuperTrapeze parts box C3 Slide the support arm 20 onto the top of the pole with the strap hook facing towards the grip 21 as shown in Figure 9 Rest the support arm against the top of the grip C4 The SuperPole installation must be completed before continuing with the SuperTrapeze installation Complete steps A3 through A11 on page 4 then continue with step C5 Figure 10 e See pages 2 3 for recommendations on SuperPole Placement and Patient Entrapment Warnings C5 Hold the trapeze handle under the support arm such that the shorter rail 23 of the handle is closest to the head of the bed as shown in Figure 10 C6 Facing the foot of the bed rotate the strap 180 degrees away from the rail open the loop on the end of the strap 22 and slide it on to the shorter rail 23 of the trapeze handle as shown in Figure 11 Slide it past the grip and along the trapeze tube until it reaches the top bend of the trapeze The handle will now be hanging as shown in Figure 10 C7 Have the user lie on the bed and place their hands palm down on their thighs Rotate the support arm around the pole until the trapeze handle hangs directly above the user s hands C8 Slide the spring collar 17 upwards on the support arm 14 assembly to gain access to the threaded holes x3 C9 Raise the support arm 20 straight up the pole We recom
5. store these instructions in a safe place for future reference WARRANTY All HealthCraft Products are covered by a one year limited warranty with the exception of hand grips which are subject to normal wear Buyer hereby indemnifies agrees to hold harmless and defend HealthCraft Products Inc from and against any and all liabilities claims founded and unfounded losses damages costs and expenses including without limitation consequential damages and reasonable professional fees resulting from buyers specification application or improper use of goods described hereon buyers omission or neglect HealthCraft Products Inc does not assume any liability for damage resulting from services performed by others or faulty installation misuse or misapplication of goods sold by HealthCraft Products Inc HealthCraft Produts Inc shall not be liable for prospective profits or special indirect or consequential damages or for the cost of any corrective work done without HealthCraft Products Inc prior approval HealthCraft Products Inc total liability hereunder shall in no event exceed the purchase price of the goods specified hereon PRODUCT COMPATABILITY CHART Z N SAFETY CONSIDERATIONS SUPERPOLE INSTALLATION MAINTENANCE The SuperPole System should only be used in locations where the floor and ceiling surfaces are structurally sound It should not be installed on loose floor coverings in rooms with
6. the room such as wall corners etc D5 Once the SuperPole is set to a true vertical position lock the angle of the pivoting bracket on both sides with the supplied hardware Refer to Figure 3 for correct configuration bolt 31 flat washer 32 split washer 33 and nut 34 Tighten with hex key 35 Continue with step A7 on page 4 of the SuperPole instructions Your SuperPole for Angled Ceiling is now installed HealthCraft Products Inc DC100 REV D Page 10 of 12 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 Specifications subject to change without notice SP ACP SUPERPOLE WITH ANGLED CEILING PLATE SP P Pole Assembly SP402 Base Plate Assembly SP198 Angled Ceiling Plate Assembly SP 513 Angle Ceiling Plate Parts Pack Ceiling Anchor Plate Assembly Angled Ceiling Plate Top Rubber Clevis Pin Nylon Washer Hitch Pin Angle Ceiling Plate Parts Pack Instructions ACP Brochure Hex Key Wrench 5 32 Cone Point Set Screw 5 16 24x x4 Pole Assembly SP402 Base Plate Assembly HealthCraft Products Inc 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 POLE ANGLED CEILING PLATE ASSEMBLY HW318 Nylon Washer HW302 Clevis Pin SP113 Pole GR101 Grip 20 long HARDWARE HW322 Hex Key 5 32 Short Arm HW151 Screw SHCH 1 4 20 x 5 8 Length HW161 Nut Nylock 1 4 20 O HW154 Flat Washer 1 4 x 5 8 OD 9 HW155 Spli
7. ATHTUB ONLY Locate pole base against tub approximately half way along its length If using SuperBar option you will need to set the pivot locking positions of the bar As a suggestion positions B or D are suitable for standing from toilet C and F for transferring into bathtub E and D for transferring out of bathtub 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 of the knees and two to six inches to side of knees when seated If using SuperBar option you will need to set the pivot locking positions of the bar As a suggestion positions A or C are suitable for standing assistance while D and E are suitable for completing a transfer to a nearby walker or wheelchair Position B provides side support if this is preferred for standing DC100 REV D Page 3 of 12 Specifications subject to change without notice SUPERPOLE INSTALLATION INSTRUCTIONS Prior to installing the SuperPole we strongly recommend that you first read through these instructions A1 Unpack the top plate 1 from the rectangular box and the pole assembly 2 from the cardboard tube remove staples to avoid scratching the paint on the pole A2 Remove the clevis pin 3 from the top plate 1 A3 Align the locking pin holes of the pole and the top plate Insert the clevis pin 3 removed in step A1 and secure with nylon washer 4 and cotter pin 5 as shown in Figure 1 A4 To prepare turn the extension screw 8 until the distan
8. ILING PLATE INSTALLATION INSTRUCTIONS Prior to installing the SuperPole with Angled Ceiling Plate we recommend that you first read through these instructions D1 Unpack the angled ceiling plate 27 from the box and the pole assembly 2 from the cardboard tube remove staples to avoid scratching the paint on the pole Remove the clevis pin 28 from the pivoting bracket of the angled ceiling plate D2 Determine the location of the pole Secure the angled ceiling plate to the ceiling making sure that it is fastened to the ceiling joists with appropriate wood screws min 10 x 2 1 2 as shown in Figure 1 D3 Slide the top end of the pole 2 onto the pivoting bracket as shown in Figure 1 Align the locking pin holes of the pole and the bracket Insert the clevis pin 28 removed in step D1 and secure with nylon washer 29 and hitch pin 30 HINT Set the extension screw 8 such that the distance from the angled ceiling plate 27 to the bottom of the extension screw is about two inches less than the actual floor to ceiling height You may need to unscrew the jam nut 9 downward to allow the extension screw to rotate Incorrect D4 Place the circular base 7 on the floor at the intended location of the SuperPole Set the SuperPole to a true vertical position as shown in Figure 2 This may be facilitated using a construction level plumb bob or by visually comparing the pole with other vertical line features in
9. ations from being too close to each other and thereby weakening the pole C12 Slide the spring collar 26 down over the screws as shown in Figure 12a Failure do so may result in injury Your SuperPole with SuperTrapeze installation is now complete HealthCraft Products Inc DC100 REV D Page 8 of 12 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 Specifications subject to change without notice STP S SUPERPOLE WITH SUPERTRAPEZE Pole Assembly SuperTrapeze Parts Box Base Plate Assembly Top Plate Assembly Trapeze Arm Assembly Trapeze Handle Assembly SuperTrapeze Parts Pack Trapeze Arm Spring Ring Plug Strap Buckle Trapeze nates Trapeze Handle Grip 6 long Grip 10 long SuperTrapeze Parts Pack SuperPole Instructions Brochure Hex Key Wrench 5 32 Cone Point Set Screw 5 16 24x x4 Pole Assembly SP402 Base Plate Assembly HealthCraft Products Inc 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 SP408 TRAPEZE ARM HW500 Plug cy HW112 SP170 B Spring Ring A f n SP123 Trapeze Arm SP125 Strap HW305 Buckle SP409 TRAPEZE HANDLE SP124 Trapeze Handle GR102 _ _ Grip 6 long GR103 Grip 10 long HARDWARE HW112 Set Screw Cone Point 5 16 24x3 8 lt lt HW320 Hex Key 5 32 Long Arm not to scale x4 il DC100 REV D Page 9 of 12 Specifications subject to change without notice ANGLED CE
10. ce from the top plate 1 to the bottom of the extension screw is about two inches less than the actual floor to ceiling height as shown in Figure 2a You may need to turn the jam nut 9 downward to allow the extension screw to rotate A5 Place the base plate 7 on the floor at the intended location of the pole Move the pole into position as shown in Figure 2b Insert the stem at the bottom of the extension LOWER POLE amp RAISE POLE screw 8 into the hole of the base plate 7 as shown in TURN SCREW TURN SCREW Figure 2c COUNTER CLOCKWISE CW CLOCKWISE HINT It is easier to swing the pole up from the side of the top plate as shown in Figure 3 If the top plate hits the ceiling prior to reaching vertical you will need to shorten the length of the extension screw A6 Set the pole to a true vertical position This may be done using a construction level plumb bob or by visually comparing the pole with other vertical line features in the room such as wall corners etc A7 While the cover sleeve 6 is held up insert a bar such A Correct Level as the shaft of a screwdriver through the drive hole at the bottom of the extension screw Turn the extension screw Clockwise CW as shown in step 1 of Figure 4 to make the top plate contact the ceiling Continue turning the extension screw approximately two to five turns until the pole is secure and ready for testing in step A8 NOTE The top plate must contact the c
11. cure installation IMPORTANT The top plate has two holes that may be used to fix this plate directly to the ceiling or ceiling joists It is strongly recommended to install screws to prevent slippage in the following situations 1 If you expect to subject the pole to heavy usage i e pole is used for more than mild support for side to side stability 2 If you are not able to inspect or have inspected and tighten if neccessary the extension screw on a monthly basis Top Plate spanning across 2 joists e Consider adding the optional Ceiling Plate Extender SP CPE to the standard SuperPole ceiling plate to increase its span from 20 to 30 Ideal where ceiling joists have increased spacing such as 24 between centers e Do not use on angled ceilings Consider adding the Angled Ceiling Plate see page 12 for this application BEDROOM Locate pole adjacent to hip belt line and BATHROOM TOILET and or BATHTUB CHAIR Locate pole three to ten inches forward as close to bed as possible while allowing clearance for bed coverings If using SuperBar option you will need to set the pivot locking positions of the bar As a suggestion positions A and E are good for moving in bed B for pulling up to sitting C for pulling up to standing and D for transferring out of bed HealthCraft Products Inc Locate pole three to ten inches forward of the knees and two to six inches to side of knees when seated B
12. e that this product is not intended as a physical constraint or barrier to exiting the bed ACCESSORIES V APPLICABLE EACH SOLD SEPARATELY X CANNOT BE USED TOGETHER FLOOR TO CEILING OPTIONS EACH SOLD SEPARATELY MODEL DESCRIPTION NUMBER CAPACITY FLOOR TO CEILING RANGE USER WEIGHT SuperPole Floor to ceiling support rail SP S SP HD SuperPole Bariatric SuperPole with increased weight capacity Uni Fit Extender Extension tube attaches to SuperPole SP UF SP ULTRA SuperPole Ultra Longer version of the SuperPole SP CUSTOM Custom Cut SuperPole Floor to ceiling measurements required CEILING PLATE ACCESSORIES EACH SOLD SEPARATELY 300lbs 136kg 450lbs 205kg 300lbs 136kg 300lbs 136kg 300lbs 136kg 93 99 236 251cm 93 99 236 251cm 100 120 254 305cm 121 140 307 356cm Less than 93 236cm Ceiling Plate Extender Longer plate 30 76cm spans wider ceiling joists 24 61cm spacing l Angled Ceiling Plate Bolts to angled ceilings between 0 45 Top plate diameter 18 45cm HealthCraft Products Inc 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 DC100 REV D Page 2 of 12 Specifications subject to change without notice GETTING STARTED We strongly recommend that you give thought as to the optimal location of your SuperPole System before installati
13. eiling squarely This can be facilitated by having a second person hold the pole vertical while another turns the extension screw A8 Test the pole by firmly holding it at mid height and vigorously attempting to force the pole from side to side Use considerable body weight momentum to conduct an aggressive test If either the base or the top plate appear to slide or shift reset the pole to vertical tighten the extension screw up to one more turn and repeat the test until the pole will not move during this test A9 Turn jam nut 9 counter clockwise CCW to make contact with the bottom of the pole as shown in step 2 of Figure 4 A10 Lock the extension screw by simultaneously turning jam nut 9 and extension screw 8 counterclockwise until jammed tight as shown in step 3 of Figure 4 When finally tight remove the turning rod A11 Slide the cover sleeve 6 down to cover the extension screw Your SuperPole installation is now complete HealthCraft Products Inc DC100 REV D Page 4 of 12 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 Specifications subject to change without notice SP P SUPERPOLE Pole Assembly Pole Parts Box Base Plate Assembly Top Plate Assembly SuperPole Parts Pack SP403 Top Plate Assembly SP403HD Top Plate Assembly Heavy Duty SP403HDU Top Plate Assembly Ultra SP P Pole Assembly SP PHD Pole Assembly Heavy Duty SP PU Pole Assembly Ultra SP500 SuperPole Parts Pack
14. ify if the bar is in the correct location ENSURE HEIGHT ORIENTATION OF CASTELLATED COLLAR IS CORRECT BEFORE PROCEEDING B10 With the castellated collar 14 in the desired location insert and tighten the three set screws 15 with the larger hex key wrench 16 as shown in Figure 8a When tightening the cone points of the set screws will penetrate the pole leaving permanent indentations as shown in Figure 8b The set screws MUST be tightened until the back end of the screw is flush with the collar or injury may result e Should you need to change the position of the height angle setting we recommend that you change the height by at least one inch This will avoid set screw indentations from being too close to each other thereby weakening the pole For the SuperPole Bariatric you may notice it requires a great deal of effort to screw in these fasteners This is due to the thicker gauge of steel used to make the pole B11 Slide the spring collar 17 downward on the castellated collar 14 as shown in Figure 8a to retain set screws 15 while in service Inspect frequently to ensure screws and collar are tight B12 Lower the T bar assembly onto the castellated collar and install the remaining white plastic pivot bushing 13 securing it with the countersunk screw 12 using the small hex key wrench 11 Your SuperPole with SuperBar installation is now complete HealthCraft Products Inc DC100 REV D Page 6 of
15. in access to the set screws as shown in Figure 8a B6 Remove the three set screws 15 from the castellated collar 14 using the large hex key wrench 16 as shown in Figure 8a B7 Slide the items in order below and as shown in Figure 6 onto the pole as straight as possible to avoid scratching the pole pivot bushing 13 bolted inside T bar assembly 10 spring collar 17 with castellated collar 14 pivot bushing 13 and cover sleeve 6 removed in step B2 B8 The SuperPole installation must be completed before continuing with the SuperBar installation Complete steps A4 to A10 on page 4 and then continue with step B9 B9 Determine the desired height and locking positions of the SuperBar as shown in Figure 7 Height of T bar The height at which the castellated collar is secured will determine the T bar assembly height Consider the z optimal height H of the bar from sitting and standing positions Figure 7 Rotational Locking Positions of T bar Each groove on the castellated collar corresponds to a rotational locking position for the T bar assembly Fix the grooves to have the T bar assembly lock where required as discussed on page 3 Getting Started We recommend a placement test lightly installing only one set screw to hold the castellated collar in place to verify the settings are suitable With this one screw in place lower the T bar assembly onto the castellated collar gently engage the lock and ver
16. mend the top of the support arm be installed approx 84 from the floor Have someone hold it here for a test or Figure 11 lightly install one set screw to hold the support arm in place C10 Set the trapeze handle to the proper height by adjusting the length of the strap When adjusted properly the users fingers should be able to comfortably grasp around the bottom rail of the trapeze handle when lying down on the bed as shown in Figure 10 TEST Have the user go through the motions of sitting up in bed as the support arm is not completely installed do not exert full weight on trapeze handle If the trapeze handle is too close or too far away for suitable support remove the set screw turn the arm to a better location and reinstall the set screw Gently retry the trapeze again and repeat until the user is satisfied ENSURE HEIGHT ORIENTATION OF SUPPORT ARM IS CORRECT BEFORE PROCEEDING C11 With the support arm 20 in the desired location tighten the three set screws 25 with the hex key wrench 24 as shown in Figure 12a When tightening the cone points of the set screws will penetrate the pole leaving permanent indentations as shown in Figure 12b The set screws MUST be tightened until the back end of the screw is flush with the collar or injury may result e Should you need to change the position of the height angle setting we recommend that you change the height by at least one inch This will avoid set screw indent
17. on The following questions may help you to decide upon a location a What motions will you be going through pulling up to standing lowering to sitting transferring from chair to toilet etc b Where will you need the most support while walking while lifting etc c What is your strongest side hand d What is your complete transfer path Will the location allow for full support over most of your path of motion e Will the pole be far enough away to allow you to stand comfortably SUPERPOLE BARIATRIC SP HD For the SuperPole Bariatric verify that both the pole and ceiling anchor plate are labelled with Heavy Duty stickers Also note the following physical differences between the standard and bariatric models e Heavier gauge thicker wall pole e Smaller diameter pole receptacle on top plate IMPORTANT The top plate for the SuperPole Bariatric MUST BE secured to the ceiling using two fasteners which are appropriate to the ceiling material At least one of the two fasteners should secure directly into a ceiling joist These fasteners are intended to prevent the top plate from dislodging under heavy use SUPERPOLE PLACEMENT STANDARD SUPREPOLE TOP PLATE It is recommended that the top plate be installed to span across two joists in a ceiling as shown below In cases where this may not be possible i e one joist only be sure to test the pole rigorously after installation to be certain of a se
18. radiant ceiling heating or mobile homes Not more than 150 Ibs should be exerted on trapeze handle sitting up assistance only If you are not equipped to undertake the outlined work we would recommend that you have your SuperPole System installed by a qualified contractor The extension screw feature of the SuperPole System can generate enough force to damage a ceiling Exercise caution when tightening this screw The SuperPole System can loosen due to settling of the floor or ceiling particularly in the first hours and days following installation and sometimes with a change of season As a result we recommend that you test that the pole is secure and the extension screw tightened if needed during this time and then on a monthly basis CAUTION It is your responsibility to see that your SuperPole System is properly assembled installed and cared for Failure to follow instructions in this manual could result in serious injury ZA WARNING PATIENT ENTRAPMENT The potential risk of entrapment limb neck head torso between the pole and adjacent item i e bed toilet etc can be reduced or avoided by the following strategies 1 Situate the pole at a distance that is considerably smaller or larger than that which could result in entrapment 2 Consider situations that could change with time or usage such as mattress compression patient movement bed position changes due to electrically powered beds etc 3 Realiz
19. re ceiling joists have increased from 0 45 degrees Screws into the ceiling spacing such as 24 between centers HealthCraft Products Inc DC100 REV D Page 12 of 12 2790 Fenton Road Ottawa Ontario Canada K1T 3T7 Specifications subject to change without notice
20. t Washer _ x2 DC100 REV D Page 11 of 12 Specifications subject to change without notice HEALTHCRAFT SuperPole Solutions Embrace life for Ceiling Challenges www healthcraftproducts com Each Sold Separately See Product Compatability Chart on Page 2 Solutions for Ceiling Height Challenges Uni Fit Extender SuperPole SuperPole Ultra 90 229cm 90 229cm SuperPole 103 262cm Floor to Floor to Floor to Ceiling Range Ceiling Range Ceiling Range 93 99 100 120 121 140 236 251cm 254 305cm 307 356cm Custom cut Extension Tube SuperPole SP s Uni Fit Extender SP UF SuperPole Ultra SP ULTRA A floor to ceiling pole that expands between the An extension tube that mounts to the top of the A longer SuperPole used with a custom cut floor and ceiling up to 8 feet to create SuperPole to increase the floor to ceiling extension tube to increase the floor to ceiling unparalleled sturdiness and reliability range up to 10 feet range up to 11 5 feet REQUIRED FOR ANGLED CEILINGS Ceiling Plate TM Extender Standard Top Plate age age TM Angled Ceiling Plate see Page 10 Ceiling Plate Extender A circular top plate that replaces the standard top plate to allow a An extension plate that increases the span of the standard SuperPole SuperPole to be installed in rooms with angled ceilings Adjustable top plate from 20 to 30 Ideal whe
Download Pdf Manuals
Related Search
Related Contents
Warehouse of Tiffany 2848BB818 Instructions / Assembly Mise en page 1 JEUNESSE : NOUVEAUTES DECEMBRE 2012 LITTERATURE Handleiding Exchange (NUWD) op Android ICS aircoolair u.e._iom_mil122e-1401 06-2013 E-Sampler Operation Manual Samsung GT-E1107 Felhasználói kézikönyv Home Accents Holiday 6050-370-200L Instructions / Assembly Le rendez-vous annuel dédié aux enjeux stratégiques et solutions Copyright © All rights reserved.