1. BODYMeDIA FIT gt Manual amp Quick Start Guide Wireless LINK Armband Model AB185 Contents Purpose of the System Cautions Get Started Your Armband Wearing Your Armband Removing the Sensor from the Strap Charging the Battery Checking Battery amp Memory Status Using Bluetooth Wireless Technology Troubleshooting Care amp Cleaning Symbol Definitions Accuracy Product Specifications Warranty User Environment Regulatory Statement Safe Disposal End User License Agreement Copyright Patent and Trademark Notice Always consult a physician before starting any new diet or exercise program This system is not to be used for diagnostic purposes and is not intended to be a substitute for the medical advice or supervision of your personal physician Materials in the Armband have been evaluated for skin contact Because everyone s skin is different you may experience irritation or redness after wearing the Armband If this occurs discontinue use and consult your physician Ifyou have known metal allergies consult your physician prior to wearing Do not wear on an open wound sore or burn To reduce potential for skin irritation wear for a maximum of 23 hours per day Be sure to leave it off one hour per day To reduce the potential risk of skin irritation be sure to dry your arm thoroughly before wearing The tab at the end of the Armband strap should be aligned to
2. 4 Type B Applied Part aS Recyclable Accuracy System Per day adults Total calories METs for free living activities mean error lt 10 Total minutes of physical activity mean error lt 5 Total step count mean error lt 9 12 Product Specifications Sensors Accelerometer 3 axis Heat Flux Skin Temperature Galvanic Skin Response GSR Materials Sensor ABS polycarbonate thermoplastic polyurethane 304 grade stainless steel Adjustable strap wing assembly Nylon polyester Lycra no latex content or polyisoprene polycarbonate thermoplastic polyurethane silicone Battery power 2 4 days under steady use Battery type Internal lithium polymer cell battery Radio Frequency 2 4GHz Contains a class 2 Bluetooth wireless technology transceiver Transmitter output power 2 5mW Memory capacity 14 days under steady use Armband size I 55mm 62mm x h 13mm 2 2 x 2 4 x 0 5 Armband weight with adjustable strap 45 4g 1 60z Water resistance IP classified only when Armband is properly inserted into the Armband strap Operating temperature humidity 5 C 40 C 40 F to 104 F 5 95 RH non condensing Storage temperature humidity 20 C 60 C 4 F to 140 F 5 95 RH non condensing Transmit Power Class 8 Less than 10mW output power Duty Cycle Class 4 permitted to operate at 100 duty cycle Receiver Class 3 Standard reliable SRD communication med
3. Air 2kV Mains N A 1kV 1 Os 1kV Differential N A 2kV Common gt 95 Dip for N A 0 5 Cycles 6096 Dip for 5 Cycles 3096 Dip for 25 Cycles gt 95 Dip for 5 Seconds 3A m 3A m 6kV Contact Electromagnetic Environment Guidance Floors should be wood concrete or ceramic tile If floors are synthetic they r h should be at least 30 Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of the Armband requires continued operation during power mains interruptions it is recommended that the Armband be powered from an uninterruptible power supply or battery Power frequency magnetic fields should be that of a typical commercial or hospital environment 17 User Environment continued Guidance and Manufacturer s Declaration Emissions The Armband is intended for use in the electromagnetic environment specified below The customer or user of the Armband should ensure that it is used in such an environment Immunity Test Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 18 IEC 60601 Test Level 3 Vrms 150 kHz to 80 MHz 3V m 80 MHz to 2 5 GHz Compliance Level 3 Vrms 150 kHz to 80 MHz 3 V m 80 MHz to 2 5 GHz Electromagnetic Environment Guidance Portable and mobile communications equipment should be separated from
4. before relying on readings The equipment of the system should not be used adjacent to or stacked with other equipment If such a setup is necessary all equipment should be checked to verify correct operation Keep this equipment out of reach of children The products contain small removable parts that may become choking hazards The equipment and wireless accessories should not be used in airplanes hospitals or any location that prohibits cellular telephones or electronic devices Do not use unapproved accessories Do not use the reminders feature of the Armband as a notification for any vital life critical events including taking medication To prevent possible damage to the USB cable grasp the plug end when disconnecting the USB cable Replace the cable if it becomes frayed DO NOT IMMERSE THE ARMBAND IN WATER The Armband is not designed to be used underwater or to come in continuous contact with water Though the Armband was designed for wearability and long term use it is a sensitive monitoring device Rough handling can break internal components Never drop or shock the Armband and always store it in a safe place when not in use Avoid exposing the equipment to extreme temperatures direct sunlight moisture sand dust or mechanical shock Do not incinerate Do not attempt to open the Armband yourself It contains no user serviceable parts Refer all servicing to qualified Service Personnel Opening the Armband
5. avoid unintended contact with the skin which may cause scratching To avoid skin burns do not wear when it has been exposed to excessively hot temperatures including direct sun exposure Be careful not to over tighten the strap while on your arm If you feel constriction or loss of circulation at any time loosen the adjustable strap and re fasten it to a more comfortable setting If you experience pain bruising swelling or discoloration of the arm discontinue use and consult a physician This product is not defibrillation proof Do not place this equipment in close proximity to other devices that can cause electromagnetic interferences of any nature The equipment is not suitable for use in the presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR OR WITH OXYGEN OR NITROUS OXIDE Medical electrical equipment requires special precautions regarding electromagnetic environments EMC and must be installed and put into service according to the EMC information provided in the User Guide Portable and mobile radio frequency RF communications equipment can effect medical electrical equipment Check the equipment for sharp edges or damage before each use Once plugged in the armband lights will blink indicating proper connection and charge progress If no indication is seen disconnect the cable and consult customer service Cautions A continued If the Armband is dropped ensure that it is working properly and not physically damaged
6. yourself will void the warranty Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Get Started Please refer to the Get Started instructions on our homepage to begin using the system It only takes a few minutes to get set up and moving toward a healthier lifestyle www bodymedia com start Your Armband Status Button _ Sensor Strap Status Lights Information on The Armband should Replace the strap obtaining replacement Weari ng Your be worn no more than if it has lost its parts can be found at 23 hours a day elasticity www bodymedia com shop Armband 6 c te Wear on the back of your left upper arm triceps be sure your upper left arm and the Armband are clean dry and free of lotion or oil Do not secure the strap too tightly It should be snug but you should be able to fit two fingers beneath the strap Secure the Velcro 5 pull tab once you have a comfortable fit The logo should face upward The silver sensors on the underside should be in contact withiyour skin ce cota prre tee cise aurea amare The Sensor will Activation is indicated There is no automatically turn on by a series of power button on and begin collecting audio tones the Armband 6 data within 10 minutes 7 Remove the Armband by stretching the elastic not by using the Velcro t
7. Armband by no less than the distances calculated listed below D 3 5 V1 Sqrt P D 3 5 E1 Sqrt P 80 to 800 MHz D 7 El Sqrt P 800 MHz to 2 5 GHz Where P is the max power in watts and D is the recommended separation distance in meters Field strengths from fixed transmitters as determined by an electromagnetic site survey should be less than the compliance levels V1 and E1 Interference may occur in the vicinity of equipment containing a transmitter Recommended Separation Distances for the Product The Armband is intended for use in the electromagnetic environment specified below The customer or user of the Armband can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF Communications Equipment and the Armband as recommended below according to the maximum output power of the communications equipment Max Output Power Watts 0 01 0 1 10 100 Separation m 150kHz to 80MHz D 3 5 V1 Sqrt 0 1166 0 3689 1 1666 3 6893 11 6666 Separation m 80 to 800MHz D 3 5 V1 Sqrt P 0 1166 0 3689 1 1666 3 6893 11 6666 Separation m 800MHz to 2 5GHz D 7 E1 Sqrt P 0 2333 0 7378 2 3333 7 3786 23 3333 19 20 Regulatory Statement FCC Declaration of Conformity We BodyMedia Inc One Gateway Center 420 Fort Duquesne Boulevard Suite 1900 Pittsburgh PA 15222 declare under our sole r
8. ab Removing the Sensor from the Strap Reattaching the Sensor Locate the USB port on the Sensor then align the port with the indentations on the side of the strap Squeeze the Sensor into the strap until it snaps lt into place v Press down on the right side of the Sensor until it separates from the strap Charging the Battery Checking Battery and Memory Status Charge the battery by connecting The Armband can store 14 days worth of data before needing to be uploaded the Sensor to your computer with To check the memory or battery status press the Armband s status button the USB cable ANG oy w i 2 Green solid Amber flashing Red flashing Battery 24 hrs of Less than 24 hrs Battery needs to be The first charge will take about 3 battery life of battery life plain nen remain remain annot collect data hours The LINK Armband works for 2 4 days before recharging is Memory 244 hrs of Less than 24 hrs Memory is full and the needed memory life of memory life sensor cannot collect remain remain additional data Upload Once plugged in the armband lights will blink data via USB cable to indicating proper connection and charge progress create room If no indication is seen it is important to disconnect 8 the cable and consult customer support 9 10 Using Bluetooth Wireless Technology Once you have regis
9. al resources please refer to www bodymedia com support Care amp Cleaning Clean the Armband regularly after sweating or when it becomes noticeably moist to ensure that it works correctly Minimize use of solvents cleaners or other chemicals and do not sterilize any part WATER RESISTANCE The Armband is not designed to be used underwater or to come into continuous contact with water Do not immerse the Armband in water CLEANING THE SENSOR Use a cloth or towel moistened with mild soap and water to wipe the side of the Sensor that touches the skin Remove any excess soap and dry with a cloth or towel completely before wearing CLEANING THE STRAP Hand wash with mild soap and warm water rinse then air dry For optimal performance and lifespan of the strap avoid machine drying DISINFECTING The Sensor may be disinfected by wiping with a soft cloth dampened with 70 isopropyl alcohol Allow 5 10 minutes for drying before wearing Always disinfect the Sensor and replace the Armband strap prior to use by others 11 Symbol Definitions Consult instructions ij for use A CAUTION sN Serial Number FCC Logo Bluetooth Wireless Co Non ionizing radiation Technolo The Waste Electrical and Electrical Equipment Regulations indicates Electrical Safety c separate collection for Armband tested to electrical and electronic applicable safety equipment standards by MET Laboratories
10. bodymedia com EULA and or in the EULA provided with the download of any such software 15 User Environment Guidance and Manufacturer s Declaration Emissions The Armband is intended for use in the electromagnetic environment specified below The customer or user of the Armband should ensure that it is used in such an environ ment Emissions Test RF Emissions CISPR 11 Harmonics IEC 6100 3 2 Flicker IEC 6100 3 3 16 Computer and Wireless Communicator Compliance Class B Group 1 The Armband uses RF energy only for its internal function Therefore its RF emis sions are very low and are not likely to cause any interference in nearby electronic equipment N A The Armband is suitable for use in all establishments including domestic and Electromagnetic Environment Guidance Diagram not to scale those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes N A Guidance and Manufacturer s Declaration Immunity The Armband is intended for use in the electromagnetic environment specified below The customer or user of the Armband should ensure that it is used in such an environ ment Immunity Test ESD IEC 61000 4 2 EFT IEC 61000 4 4 Voltage Dips Dropout IEC 61000 4 11 Power Frequency 50 60H Magnetic Field IEC 61000 4 8 IEC 60601 Test Compliance Level Level 6kV Contact x8kV Air 8
11. e electrical and electronic equipment This will help to conserve natural resources and ensure that the Armband is recycled in a manner that protects human health and the environment For more information on where you can drop off your waste equipment for recycling please contact your local township municipality or city your household waste disposal service or the store where you purchased the Armband End User License Agreement The firmware included in and certain software provided and associated with the product is subject to a BodyMedia Software License Agreement as set forth here www bodymedia com Support Help Policies EULA 21 22 Copyright Patent amp Trademark Notice The products and services which include the software firmware algorithms processes and methods of BodyMedia FIT SenseWear applications and other applicable BodyMedia applications as well all devices and components used therewith including the Armband Display and Wireless Communicator are covered by one or more of the following patents United States Patent Nos D439 981 D651 552 D632 396 D645 968 6 527 711 6 595 929 6 605 038 7 020 508 7 153 262 7 261 690 7 285 090 7 689 437 and 8 157 731 European Patent Nos 1 292 217 and 1 292 218 Canadian Patent Nos 2 413 220 and 2 501 899 S Korean Patent Nos KR 10 083 1036 10 0821945 10 1107062 10 0885030 and 10 0956791 Israeli Patent Nos 153478 153516 158067 160079 and 167045 Japan
12. ese Patent Nos JP 1138499 JP 4 125 132 JP 4 283 672 and JP 4 813 058 Mexican Patent Nos MX 242292 236870 250153 245862 250156 269421 and 271678 Brazilian Patent Nos 0111918 4 and PI0111995 8 and various worldwide patents pending This notice is accurate as of November 7 2012 For the latest information please contact BodyMedia BodyMedia BodyMedia FIT the Four Circle Design Put On The Armband Take Off The Pounds and SenseWear are trademarks or registered trademarks of BodyMedia Inc Manual firmware or software on armband display device or mobile device related algorithms and software and firmware utilized by BodyMedia products services and or applications Copyright 2011 2012 BodyMedia Inc All rights reserved Any copying use distribution or reverse engineering without a specific license from BodyMedia Inc or as permitted by applicable law is strictly prohibited Made for iPod and Made for iPhone mean that an electronic accessory has been designed to connect specifically to iPod or iPhone respectively and has been certified by the developer to meet Apple performance standards Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards Please note that the use of this accessory with iPod or iPhone may affect wireless performance Android is a trademark of Google Inc The Bluetooth word mark and logos are registered trade
13. esponsibility that the products BodyMedia Inc and BodyMedia Armband Model AB185 comply with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in stalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help A CAUTION Changes or modifications to this equip
14. ia 13 14 Warranty Unless otherwise set forth in a separate limited warranty description included with the BodyMedia Hardware including Armband Display with Clip and Watch strap BodyMedia warrants that BodyMedia Hardware is free of defects in materials and workmanship under normal use and service Limited Warranty for 1 year from the date the product is purchased by the original retail purchaser the Limited Warranty Period This warranty is only valid for the original retail purchaser and only from the date of initial retail purchase and the purchaser must provide proof of purchase The purchaser will be responsible for and pre pay all return shipping charges and shall assume all risk of loss or damage to product while in transit to BodyMedia We recommend that you use a traceable method of shipping for your protection If a defect covered by this Limited Warranty occurs during the Limited Warranty Period BodyMedia will at its option repair or replace the entire unit or refund the original purchase price The foregoing remedies are purchaser s sole and exclusive remedy and BodyMedia s sole and exclusive liability for breach of the Limited Warranty This Limited Warranty is subject to compliance with the applicable user guides for the BodyMedia Hardware and does not apply to normal wear and tear or damage caused by improper or incorrectly performed maintenance negligence accident misuse or unreasonable use modif
15. ication tampering or any other causes not related to design materials or workmanship This Limited Warranty excludes replaceable batteries EXCEPT AS SPECIFIED IN THIS LIMITED WARRANTY SECTION ALL EXPRESS OR IMPLIED WARRANTIES CONDITIONS AND REPRESENTATIONS INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE NON INFRINGEMENT QUALITY NON INTERFERENCE ACCURACY OR ARISING FROM A COURSE OF DEALING PERFORMANCE USAGE OR TRADE PRACTICE ARE HEREBY EXCLUDED TO THE EXTENT ALLOWED BY APPLICABLE LAW AND ARE EXPRESSLY DISCLAIMED BY BODYMEDIA TO THE EXTENT AN IMPLIED WARRANTY CANNOT BE EXCLUDED SUCH WARRANTY IS LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD BECAUSE SOME STATES OR JURISDICTIONS DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS THE ABOVE LIMITATION MAY NOT APPLY THESE WARRANTIES GIVE CUSTOMER SPECIFIC LEGAL RIGHTS AND CUSTOMER MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION SUBJECT TO APPLICABLE LAW IN NO EVENT SHALL BODYMEDIA S LIABILITY EXCEED THE PURCHASE PRICE OF THE BODYMEDIA HARDWARE This disclaimer and exclusion shall apply even if the Limited Warranty set forth above fails of its essential purpose This limited warranty does not apply to any firmware included in or software provided and associated with the product All such firmware and software is licensed under a separate end user license agreement a www
16. marks owned by Bluetooth SIG Inc and any use of such marks by BodyMedia Inc is under license Other trademarks and trade names are those of their respective owners e 5 BodyMedia Inc One Gateway Center 420 Fort Duquesne Blvd Suite 1900 Pittsburgh PA 15222 USA www bodymedia com 100706_REV6 Copyright 2012 BodyMedia Inc
17. ment not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment RF Exposure information See 2 1093 of the FCC Rules This product is a Type B Applied Part complying with the specified requirements of the Standard to provide protection against electric shock particularly regarding allowable Leakage Current This Class B digital apparatus complies with Canadian ICES 003 Cet apareil num rique de la classe B est conforme a la norme NMB 003 du Canada IEC 60601 1 1988 A1 1991 A2 1995 Medical Electrical Equipment Part 1 GeneralRequirements for Safety EN 60601 1 2001 Medical Electrical Equipment Part 1 General Requirements for Safety UL 60601 1 Medical Electrical Equipment Part 1 General Requirements for Safety Ist Edition CSA C22 2 No 601 1 M90 Medical Electrical Equipment Part 1 General Requirements for Safety 47CFR Part 15 Subpart B amp ICES 003 Issue 4 February 2004 for Class B Digital Devices 47CFR Part 15 Subpart C 15 247 amp RSS 210 Issue 7 June 2007 for Intentional Radiators ETSI EN 301 489 1 with ETSI EN 301 489 17 Article 3 1 b of R amp TTE Directive RoHS requirements Safe Disposal If you want to dispose of the Armband please do not use the ordinary trash This product must not be disposed of with your other household waste Dispose of the Armband equipment by taking it to a designated collection point for the recycling of wast
18. tered the Armband to your account connect to a smartphone with Bluetooth using pairing For the latest information and instructions please visit bodymedia com Bluetooth iPhone bodymedia com Bluetooth Android 1 PUT THE ARMBAND IN PAIRING MODE Hold down the Armband s status button for 5 seconds The status lights will alternate in amber to indicate that the pairing mode is active Pairing mode will remain active for several minutes 2 SET YOUR SMARTPHONE TO DISCOVER THE ARMBAND First ensure that Bluetooth is activated on your phone Discover the Armband by going to a setup connect or Bluetooth menu on your phone and select discover or add a Bluetooth device 3 YOUR SMARTPHONE WILL FIND THE ARMBAND The Armband will be named XY s Armband X first name initial and Y last name initial of the name registered to the Armband Accept your phone s request to pair by pressing Yes or ok and confirm with the passkey or PIN 0000 4 zeros Your phone will confirm when pairing is complete If pairing is unsuccessful go back to Step 1 and try again 4 CONNECT AND INSTALL THE APPLICATION Once your Armband is paired press the status button to connect The status lights will alternate in green while the Armband looks for the application The phone may automatically find the Application or require you to search Troubleshooting For troubleshooting information and addition
Download Pdf Manuals
Related Search
BodyMedia bodymedia bodymedia fit bodymedia armband bodymedia sensewear bodymedia international bodymedia karriere bodymedia fachmagazin bodymedia innovation days bodymedia gmbh bodymedia mediadaten
Related Contents
Bomba de dosagem magnética delta® DLTa, com accionamento TRC-145 MANUAL DE INSTRUÇÕ ES telecharger la documentation au format pdf Silverstone SST-ML06B computer case Service Manual - K&T Parts House Lawn Mower Parts & Chain Saw Shure SLX Sem Fio Copyright © All rights reserved.
Failed to retrieve file