Home
EZ-Line Retractable Horizontal Lifeline System Manual
Contents
1. Instructions for the following series products EZ Line Horizontal Lifeline System Model Number 7605060 USER INSTRUCTION MANUAL EZ LINE HORIZONTAL LIFELINE SYSTEM This manual is intended to meet the Manufacturer s Instructions as recommended by OSHA and should be used as part of an employee training program WARNING This product is part of a fall arrest system These instructions must be provided to the user of this equipment The user must read and understand these instructions or have them explained to them before using this equipment The user must read and follow the manufacturer s instructions for each component or part of the complete system Manufacturer s instructions must be followed for proper use and maintenance of this product Alterations or misuse of this product or failure to follow instructions may result in serious injury or death IMPORTANT If you have questions on the use care or suitability of this equipment for your application contact DBI SALA IMPORTANT Before using this equipment record the product identification information from the ID label into the inspection and maintenance log in section 9 of this manual Figure 1 Typical EZ Line Horizontal Lifeline System Configuration Carabiner Lifeline Anchorage Impact Indicator Housing S Housing Anchorage Carabiner End Stanchion RFID Tag Carabiner Lifeli
2. connect the crank handle to the top output and rotate clockwise for about 20 press the top button simultaneously and allow the crank handle to rotate counterclockwise See Figure 10 Step 6 After use retract the lifeline back into the casing by connecting the crank handle to the bottom output and rotating it counterclockwise See Figure 11 Figure 8 Extending the Lifeline Push and hold button Figure 10 Allowing Slack in the Lifeline Figure 11 Retracting the Lifeline 3 3 OPERATION A PERSONAL FALL ARREST SYSTEM COMPONENTS Inspect and don a full body harness according to the manufacturer s instructions Attach the connecting subsystem energy absorbing lanyard or SRL to the dorsal connection on the harness CONNECTING TO THE HLL SYSTEM Approach the work area using the appropriate access equipment Connect the personal fall arrest system to the HLL Connectors must meet all compatibility and strength requirements WARNING Both ends of the lifeline must be securely attached to appropriate anchors when in use Never attach the end of the lifeline to a harness to use it in the manner of a winch or SRL 3 4 4 0 4 1 HAZARDOUS SITUATIONS Do take unnecessary risks such as jumping reaching too far from the edge of the working surface Do not allow the connecting subsystem to pass under arms or between feet
3. s instructions 7 0 SPECIFICATIONS 7 1 MATERIALS Lifeline Wire Rope 1 4 inch diameter 7x19 galvanized steel Carabiners Zinc plated high tensile alloy steel 5 000 Ibs 22 2 minimum tensile strength Thimbles Galvanized steel Ferrules Aluminum 7 2 INTERNAL ENERGY ABSORBER PERFORMANCE Peak Dynamic Pullout Load 2 500 Ibs 11 1 kN Average Dynamic Pullout Load 2 000 Ibs 8 9 kN Maximum Pullout 4 ft 6 in 60 ft Span length in feet 1 4 m 18 3 m Span length in meters Minimum Tensile Strength 5 000 Ibs 22 2 kN Patent Pending 8 0 LABELING 8 1 The following labels must be present and fully legible 9502375 REV A 2 USERS 2 UTILISATEURS 1 USER 1 UTILISATEUR SHOCK ABSORBING LANYARD SHOCK ABSORBING LANYARD LONGE A ABSORBEUR D ENERGIE LONGE A ABSORBEUR D ENERGIE 1 y X W W X Y 1 18 2 5 5 17 2 5 2 16 2 4 9 15 2 46 ee 16 0 4 9 17 0 5 2 18 0 5 5 119 0 5 8 A 18 8 5 8 17 8 5 4 16 8 5 1 115 8 4 8 17 3 5 3
4. 18 3 5 6 19 3 5 9 20 3 6 2 2 19 5 6 0 18 5 5 6 17 5 5 3 16 5 5 0 18 5 5 6 19 5 6 0 20 5 6 3 21 5 6 6 2 D 20 21 6 2 19 2 5 9 118 2 5 5 17 2 5 2 D D 19 8 6 1 20 8 6 4 21 8 6 7 22 8 7 0 D E 20 8 6 4 19 8 6 1 118 8 5 8 17 8 5 4 E E 21 11 6 4 22 1 6 7 23 1 7 0 241 7 4 E F 21 5 6 6 20 5 6 3 119 5 6 0 18 5 5 6 F F 22 3 6 8 23 3 7 1 124 3 7 4 25 3 7 7 F CLEARANCE TIRANT D AIR CLEARANCE TIRANT 1 PER LIFELINE CARACTERISTICS CARACTERISTIQUES DE LA LIGNE DE VIE R TYPE G 1 4 diameter galvanized wire ES c ble en acier galvaniz de diam tre 6 3 mm 88 3 amp o 88 z 5 Oss 25 5 EES H ES AJBICID EJE L O2sree Fron _ 2 8 amp 3 as M 3 1 6 1 9 2 12 2 15 3118 3 SERVICE DATES Ope LE 5 SELF RETRACTING LIFELINE DATES DE REPARATION wig cers ANTICHUTE RAPPEL AUTOMATIQUE n 3 Og 1 USER 2 USERS ag amp 8 1 UTILISATEUR 2 UTILISATEURS LPS a 58 E SE FILM 74123 8 2125 A 9502374 REV 180124 901281 86126 98130 D 192128 tt 10 71337 D E 98129 5135 TE F 103132 I T Patent pending 5 CLEARANCE TIRANT DAR Use this crank to tension the lifeline by connecting it to the top output as shown Wind lifeline in untill a click The lifeline is now correctly tensioned Utiliser cette maniv
5. 7 22 10 7 0 40 12 2 50 15 2 21 1 6 4 22 1 6 7 23 1 7 0 24 1 7 3 50 15 2 60 18 3 22 4 6 8 23 4 7 1 24 4 7 4 25 4 7 7 Figure 7 Clearance Evaluation Using DBI SALA Self Retracting Lifelines 1 2 Required Clearance from nearest lower level or obstruction to working level Example For one user per span where the span length is 24 ft the required clearance is 8 ft 7 in Span Length Self Retracting Lifeline Find your system s SPAN LENGTH row in the Clearance Table Read the corresponding height specified in the Required Clearance column to determine if your system has adequate clearance in the event of a fall If your clearance is inadequate do not use the system or reduce your span length and re evaluate your required clearance Working Level Lower level or obstruction WARNING This information only applies when the HLL and SRL are located above the level of the harness attachment point and the user is standing Clearance Table One User Per Span DBI SALA Self Retracting Lifelines Span Length Dimensions in Feet Required Clearance meters in paranthesis Dimensions in Ft In Greater than Less than or meters in paranthesis equal to 7 ft 5 in 2 3 8 ft O in 2 4 8 ft 7 in 2 6 9 ft 2in 2 8 9 ft 10 in 3 0 10 ft 4in 3 1 Cleara
6. R sistance des points d ancrage minimum 5000 Ibs 2200 L utilisation d un harnais int gral est imp rative avec cet appareil S assurer que la ligne de vie est situ e une levation qui limitera la chute libre 1 80 lors de l utilisation avec un absorbeur d nergie et situ e directement au dessus de l utilisateur lors de l utilisation avec un antichute rappel automatique Eviter tout contact entre la ligne de vie et des angles vifs A utiliser uniquement por des personnes form es S assurer de la bonne connexion aux points d ancrage avant utilisation La ligne de vie doit tre correctement tendue avant utilisation voir la notice pour plus de d tails D connecter la manivelle des sorties avant SERIAL NO NUMERO DE SERIE XXXXXXX from service for repair Do not use if inspection reveals an unsafe condition Not user repairable Avant chaque utilisation inspecter l appareil selon la notice en incluant le fonctionnement du m canisme de blocage tirer fermement pour tester l tat de ligne de vie le fonctionnement et l tat des connecteurs des capots et de la visserie la lisibilit des tiquettes et toute vidence de d fauts dommages ou pi ces manquantes Inspection par une personne comp tente n cessaire au moins une fois par an voir la notice Inspecter le t moin de chute l ctr mite de la ligne de c t mousqueton une partie cass e est une indication qu un impact eu lieu et que l appareil d
7. before reuse See Figure 13 Step 6 Pull sharply on the lifeline close to the device end to ensure that the lifeline is secured Step 7 Repeat step 4 of section 3 2 of this manual to ensure that the lifeline is under the correct tension If not necessary do not apply any extra tension on the lifeline during this operation just make sure that the crank handle clicks Step 8 Inspect system labels The labels must be present and fully legible See section 8 Replace labels if missing or illegible IMPORTANT If this equipment is subjected to the forces of a fall arrest it must be removed from service and destroyed or returned to DBI SALA for inspection or repair 5 5 If inspection reveals an unsafe or defective condition remove unit from service and destroy or contact DBI SALA for possible repair 5 6 USER EQUIPMENT Inspect harnesses and energy absorbing lanyards or SRL s used with the HLL system according to manufacturer s instructions e Annually This equipment must be inspected according to steps listed in section 5 4 by a competent person other than the user at least annually Record the results of each inspection in the inspection and maintenance log in section 9 IMPORTANT Extreme working conditions harsh environments prolonged use etc may require increasing the frequency of inspections 5 7 If inspection reveals an unsafe or defective condition remo
8. connecting subsystem length should be kept as short as possible to reduce the potential free fall and required clearance distance Both anchorages must be installed at approximately the same elevation so that the horizontal lifeline system is not sloped more than 15 Step 1 Determine the locations of the end anchorages and evaluate their strengths in accordance with section 2 4 Determine the span length and evaluate the required clearance using Figure 6 or 7 Figure 6 specifies minimum clearance for one or two users per span using shock absorbing lanyards Figure 7 specifies clearance for one or two users per span using self retracting lifelines Figure 6 Clearance Evaluation Using DBI SALA Energy Absorbing Lanyards Span Length po Clearance Table for One User per Span DBI SALA Energy Absorbing Lanyards lt Energy Absorbing Lanyard Length Energy Absorbing Lanyard Required Clearance from nearest lower level or obstruction to HLL system height 1 Select the row that corresponds to your system s span length in the SPAN LENGTH column of the Clearance Table 2 Find the column that represents the length of lanyard you are using 3 The required clearance is found where the SPAN LENGTH row and the lanyard length column intersect Use this distance to determine if adequate clearance exists in the event of a fall If there is inadequate clearance do not use the system or reduce
9. fall arrest that are perpendicular to the axis of the horizontal lifeline See Figure 5 Figure 5 Anchorage Strengths 5 000 Lbs 22 2 kN Min 5 000 Lbs 22 2 KN Min 2 A 7 WARNING Anchorages must be rigid Large deformations of the anchorage will affect system performance and may increase the required fall clearance below the system which could result in serious injury or death 3 600 Lbs 16 0 kN Minimum all potential directions of fall arrest applied loading 2 5 CONNECTING SUBSYSTEM The connecting subsystem is the portion of the personal fall arrest system that is used to connect between the horizontal lifeline subsystem and harness fall arrest attachment element The connecting subsystem must limit forces applied to the horizontal lifeline to 900 Ibs 4 0 kN or less 3 0 OPERATION AND USE WARNING Do not alter or intentionally misuse this equipment Use caution when using this equipment around moving machinery electrical and chemical hazards and sharp edges WARNING Consult your doctor if there is reason to doubt your fitness to absorb the impact from a fall arrest Age and fitness can affect your ability to withstand fall arrest forces Pregnant women and minors must not use this system 3 1 BEFORE EACH USE inspect this equipment according to steps listed in section 5 4 Do not use this equipment if inspection reveals an unsafe or defe
10. the span or lanyard length and re evaluate the required clearance Example For a single user per span with a span length of 42 ft and lanyard length of 6 ft the required clearance is 20 ft 10 in Lower level or obstruction Spa Dimensions in Feet meters in paranthesis in Length Length of Energy Absorbing Lanyard Dimensions in Ft In meters in paranthesis Greater than 0 0 Less than or equal to 3 0 9 4 0 1 2 5 0 1 5 6 0 1 8 10 3 1 15 2 4 6 16 2 4 9 17 2 5 2 18 2 5 5 10 3 1 20 6 1 15 10 4 8 16 10 5 1 17 10 5 4 18 10 5 7 20 6 1 30 9 1 40 12 2 30 9 1 17 6 5 3 18 6 5 6 19 6 5 9 40 12 2 18 2 5 5 19 2 5 8 20 2 6 1 50 15 2 17 10 5 4 18 10 5 7 19 10 6 0 20 10 6 4 50 15 2 60 18 3 18 6 5 6 19 6 5 9 20 6 6 2 21 6 6 6 Clearance Table for Two Users per Span DBI SALA Energy Absorbing Lanyards Span Length Dimensions in Feet meters in paranthesis Greater than Length of Energy Absorbing Lanyard Dimensions in Ft In meters in paranthesis Less than or equal to 3 0 9 4 0 1 2 5 0 1 5 6 0 1 8 0 0 10 3 1 16 0 4 9 17 0 5 2 18 0 5 5 19 0 5 8 10 3 1 20 6 1 17 3 5 3 18 3 5 6 19 3 5 9 20 3 6 2 20 6 1 30 9 1 18 6 5 6 19 6 5 9 20 6 6 2 21 6 6 6 30 9 1 40 12 2 19 10 6 0 20 10 6 4 21 10 6
11. vigilant lors d une utilisation proximit de sources thermiques lectriques ou chimiques Ne pas utiliser comme cbsorbeur d nergie individuel Ne pas enlever cette tiquette 9502372 REV A utilisation USE UTILISATION Anchorages strength requirement 5000 Ibs 22kN Full body harness is required for use with this device Ensure horizontal lifeline is located at an elevation which will limit free fall to maximum of 6 feet when using shock absorbing lanyards and located overhead when using self retracting lifelines Avoid lifeline contact with sharp edges For use by troined persons only Ensure connection to anchorage is secured properly before use The lifeline must be orrectly tensioned for optimal performance see user manual for more details Disconnect crank from outputs legibility of labels and any evidence of defects damage or missing parts Inspection by competent person required ot least annually see user manual Inspect impact indicator at the karabiner end of the lifeline a ruptured section is an indication that an impact has occurred and the unit must be removed from service for repair If used to arrest fall remove INSPECTION Before each use inspect device in accordance with user manual including locking function pull strongly to test condition of lifelines function and condition of connector housing and fasteners before connecting to lifeline
12. To avoid inadequate clearance do not climb above the HLL To avoid swing fall hazards do not work too far from either side of the HLL TWO PERSONS CONNECTED TO THE HLL When a person falls while connected to the HLL the system will deflect If two persons are connected to the same HLL and one person falls the second person may be pulled off the working surface due to deflection The potential for the second person falling increases as the HLL span length increases The use of independent HLL systems for each person or shorter span length is recommended to minimize the potential of the second person falling FREE FALL The personal fall arrest system must be rigged to limit free falls to 6 ft 1 8 m or less when using an energy absorbing lanyard or such that the SRL is overhead and without slack according to OSHA requirements SHARP EDGES Avoid working where the connecting subsystem or other system components will be in contact with or abrade against unprotected sharp edges If working around sharp edges is unavoidable a protective cover must be used to prevent cutting of the PFAS components IN THE EVENT OF A FALL The responsible party must have a rescue plan and the ability to implement a rescue Tolerable suspension time in a full body harness is limited so a prompt rescue is critical RESCUE With the number of potential scenarios for a worker requiring rescue an on site rescue team is beneficial The rescue team is given the too
13. ctive condition Plan your use of the fall protection system prior to exposing workers to dangerous situations Consider all factors affecting your safety before using this system A READ AND UNDERSTAND all manufacturer s instructions for each component of the personal fall arrest system All DBI SALA harnesses and connecting subsystems are supplied with separate user instructions Keep all instructions for future reference B Review sections 1 and 2 to ensure system limitations and other requirements have been adhered to Review applicable information regarding system clearance criteria and ensure changes have not been made to the system installation i e length or occurred at the job site that could affect the required fall clearance Do not use the system if changes are required 3 2 SYSTEM INSTALLATION Figure 1 shows typical horizontal lifeline system installations When using an energy absorbing lanyard to connect to the system the end anchorages must be located at a height which will limit the free fall to 6 ft 1 8 m When using a self retracting lifeline SRL to connect to the system the end anchorages must be located above the user The SRL when fully retracted must be above the harness attachment level The horizontal lifeline system should be positioned at a level that will minimize free fall while allowing ease of use The horizontal lifeline should be positioned near the work location to minimize swing fall hazards The
14. e 2 Anchorage Connecting Subsystem CONNECTING SUBSYSTEM Each person s connecting subsystem must limit fall arrest forces to 900 Ibs 4 0 KN or less See section 2 5 ANCHORAGES The EZ Line Horizontal Lifeline System must be installed on anchorages that meet the requirements specified in section 2 4 ENVIRONMENTAL HAZARDS Use of this equipment in areas where physical or environmental hazards are present may require additional precautions to reduce the possibility of injury to the user or damage to the equipment Hazards may include but are not limited to high heat caustic chemicals corrosive environments high voltage power lines explosive or toxic gases moving machinery or sharp edges Contact DBI SALA if you have questions about using this equipment where physical or environmental hazards exist TRAINING This equipment must be installed and used by persons trained in its correct application and use See section 4 1 3 APPLICABLE STANDARDS Refer to national standards including local state and federal OSHA requirements for more information on work positioning systems and associated components 2 0 SYSTEM REQUIREMENTS 2 1 COMPATIBILITY OF CONNECTORS DBI SALA equipment is designed for use with DBI SALA approved components and subsystems only Substitutions or replacements made with non approved components or subsystems may jeopardize compatibility of equipment and may effect the safety and reliab
15. elle pour tendre la ligne de vie en la connectant la sortie la plus haute comme montr ci joint Enrouler la ligne de vie jusqu ce qu un click se fasse entendre La ligne de vie est alors correctement tendue AJY 70G6 Ser LE AWARNING AVERTISSEMENT Crank Handle Label www copitalsafety com USA 800 328 6146 33 4 97 10 00 10 CANADA NE LD 800 387 7484 44 1928 57 13 24 ASIA AUSTRALIA 852 2992 0381 800 245 002 Clearance Label Manufacturer s instructions must be read and understood prior to use Instructions supplied with this product at time of shipment must be followed for proper use maintenance and inspection Alteration or misuse of this product or failure to follow instructions may result in serious injury or death Moke only compatible connections Exercice caution using this equipment near hazardous thermal electrical or chemical sources Do not use as a personnal energy absorber Do not remove this label Les instructions du fobriquant doivent tre lues et comprises pr alablement l utilisation est imp ratif d observer les instructions fournies avec ce produit au moment de l exp dition pour bien l utiliser l entretenir et l inspecter Une modification ou un usage abusif de ce produit ou le fait de n gliger d observer les instructions peut entra ner des blessures graves voire mortelles Effectuer seulement des fixations compatibles Rester
16. ility of the complete system 2 2 COMPATIBILITY Connectors are considered to be compatible with connecting elements when they have been designed to work together in such a way that their sizes and shapes do not cause their gate mechanisms to inadvertently open regardless of how they become oriented Contact DBI SALA if you have any questions about compatibility Connectors hooks carabiners and D rings must be capable of supporting at least 5 000 Ibs 22 2 kN Connectors must be compatible with the anchorage or other system components Do not use equipment that is not compatible Non compatible connectors may unintentionally disengage See Figure 3 Connectors must be compatible in size shape and strength Self locking snap hooks and carabiners are required by ANSI Z359 1 and OSHA Figure 3 Unintentional Disengagement Roll out Small ring or other non compatibly shaped element 1 Force is applied to the 2 The gate presses against 3 The gate opens allowing the snap hook the connecting ring snap hook to slip off 2 3 MAKING CONNECTIONS Only use self locking snap hooks and carabiners with this equipment Only use connectors that are suitable to each application Ensure all connections are compatible in size shape and strength Do not use equipment that is not compatible Ensure all connectors are fully closed and locked DBI SALA connectors snap hooks and carabiners are designed to be used only a
17. inventory control and provide records for your fall protection equipment BEFORE EACH INSTALLATION Inspect the system components according to these or other manufacturer s instructions System components must be formally inspected by a competent person other than the user at least annually Formal inspections should concentrate on visible signs of deterioration or damage to the system components Items found to be defective must be replaced Do not use components if inspection reveals an unsafe or defective condition Record the results of each formal inspection in the Inspection and Maintenance log in section 9 or use the i Safe inspection web portal to maintain your inspection records If you are a first time user contact a Customer Service representative in the US at 800 328 6146 or in Canada at 800 387 7484 or if you have already registered go to www capitalsafety com isafe html Follow instructions provided with your i Safe handheld reader or on the web portal to transfer your data to your web log INSTALLED SYSTEMS An inspection of the HLL system by a competent person must be completed after the system is installed The system must be periodically inspected by a competent person when left installed for an extended period and prior to each day s use Periodic inspections should be performed at least monthly or more frequently when site conditions and use warrant Inspections of installed systems should include the inspection steps lis
18. ls both in equipment and techniques so it can perform a successful rescue Training should be provided on a periodic basis to ensure rescuers proficiency SYSTEM REMOVAL When no longer required the HLL system should be removed from the job site To slacken the HLL connect the crank to the top output and rotate clockwise for about 20 press the top button simultaneously and allow the crank to rotate counterclockwise Disconnect the HLL system from the anchorages Retract the lifeline back into the housing by connecting the crank handle more likely to the bottom output and rotate counterclockwise Ensure there are no knots or kinks in the lifeline as you retract it TRAINING It is the responsibility of all users of this equipment to understand these instructions and are trained in the correct installation use and maintenance of this equipment These individuals must be aware of the consequences of improper installation or use of this equipment This user manual is not a substitute for a comprehensive training program Training must be provided on a periodic basis to ensure proficiency of the users WARNING Training must be conducted without exposing the trainee to a fall hazard Training should be repeated on a periodic basis 5 0 INSPECTION 5 1 5 2 5 3 5 4 The i Safe RFID tag on this HLL can be used in conjunction with the i Safe handheld reading device and the web based portal to simplify inspection and
19. nce Table Two Users Per Span DBI SALA Self Retracting Lifelines Span Length Dimensions in Feet Required Clearance meters in paranthesis Greater than Dimensions in Ft In Less than or meters in paranthesis equal to 8 ft 2 in 2 5 9 ft 0 in 2 7 9 ft 10 in 3 0 10 ft 8 in 3 3 11 ft 6 in 3 5 12 ft 4in 3 8 Step 2 Press on the button on top of the housing and hold it down to pay out the required amount of lifeline by pulling out the line Make sure the crank handle is not connected to any output during this operation See Figure 8 When the button is released it will spring back up and the lifeline will lock in place If the lifeline does not lock do not use The unit must be returned to an authorized dealer for service Step 3 Install the horizontal lifeline to anchorage connectors using the carabiners provided See Figure 1 Refer to manufacturer s instructions provided with the anchorage connectors for installation requirements Step 4 Connect the crank handle to the top output and remove excess Slack by rotating clockwise The lifeline must be tensioned until a CLICK and a slight rotation of the crank arm relative to the crank body occur See Figure 9 When the crank handle is released it will return to its original position in line with the crank body Step 5 If slack is needed to make an adjustment to the system or for ease in removing the system
20. ne Intermediate Jl Stanchion Zorbit Energy Carabiner Absorber S Carabiner RFID Tag i End Ss Stanchion Impact Indicator Form 5902346 Rev D Copyright 2008 DB Industries Inc DESCRIPTIONS The EZ Line Horizontal Lifeline System is a temporary horizontal lifeline system that retracts into a housing for easy storage and portability 1 0 APPLICATIONS 1 1 PURPOSE The EZ Line Horizontal Lifeline System is designed for use as an anchoring means for one or two personal fall arrest systems PFAS Use the EZ Line Horizontal Lifeline HLL where horizontal mobility and fall protection are required The EZ Line Horizontal Lifeline System can also be used in combination with DBI SALA stanchions Up to three spans are then permissible with up to two users connected to each span IMPORTANT For multi span use the use of a secondary HLL energy absorber such as a Zorbit Energy Absorber at the opposite end of the device is mandatory See Figure 1 for a typical installation 1 2 LIMITATIONS Consider the following application limitations before using this equipment A HORIZONTAL LIFELINE SPAN The maximum horizontal lifeline span length is 60 feet 18 3 m see Figure 1 The span length must be reduced when clearance is limited See section 3 2 for clearance information CAPACITY For a single span use the maximum capacity of the EZ Line H
21. oit tre retir du service pour r paration Si l appareil a t utilis pour arr ter une chute il doit tre retir du service Ne pas utiliser si l inspection r v le un tat dangereux Non r parable par l utilisateur 10 MFRD YR MO DATE AA MM LOT FAB AA MM NS Re LENGTH FT UFELINE TYPE see back LONGUEUR DE LIGNE DE voir au dos CE 0086 EN 795 1996 Class Warning Use ID Label 9 0 INSPECTION AND MAINTENANCE LOG SERIAL NUMBER MODEL NUMBER DATE PURCHASED DATE OF FIRST USE INSPECTION DATE INSPECTION ITEMS NOTED CORRECTIVE ACTION MAINTENANCE PERFORMED Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By Approved By 11 A Capital Safety Company USA Capital Safety Distributed by Engineered Fall Protection 3833 SALA Way Email sales engineeredfallprotection com Red Wing MN 55066 5005 Web www engineeredfallprotection com PH 314 492 4422 FAX 800 570 5584 OO Certificate No FM 39709 12
22. orizontal Lifeline System is two persons For a multi span use the maximum capacity of the EZ Line Horizontal Lifeline System is two persons connected to each span The maximum number of spans is three The maximum weight of each person including tools and clothing is 310 Ibs 141 kg BODY SUPPORT The EZ Line Horizontal Lifeline must only be used with personal fall arrest systems incorporating a full body harness FALL CLEARANCE There must be sufficient clearance below the worker to arrest a fall before striking the lower level or obstruction See section 3 2 for required clearance information FREE FALL Rig and use the personal fall arrest system such that the maximum potential free fall does not exceed government regulatory and subsystem manufacturer s requirements See section 3 0 and subsystem manufacturer s instructions for more information SWING FALLS Swing falls occur when the anchorage point is not Figure 2 Swing Fall Hazard directly overhead The force of striking an object in a swing fall may cause serious injury or death Minimize swing falls by working as directly below the point as possible Do not permit a swing fall if injury could occur Swing falls will significantly increase the Point clearance required when a self retracting lifeline or other variable length connecting subsystem is used If a swing fall situation exists in your application contact DBI SALA before proceeding See Figur
23. s specified in each product s user instructions See Figure 4 for inappropriate connections DBI SALA snap hooks and carabiners should not be connected A To a D ring to which another connector is attached B In a manner that would result in a load on the gate NOTE Large throat opening snap hooks should not be connected to standard size D rings or similar objects which will result in a load on the gate if the hook or D ring twists or rotates Large throat snap hooks are designed for use on fixed structural elements such as rebar or cross members that are not shaped in a way that can capture the gate of the hook In a false engagement where features that protrude from the snap hook or carabiner catch the anchor and without visual confirmation seems to be fully engaged to the anchor point D To each other E Directly to webbing or rope lanyard or tie back unless the manufacturer s instructions for both the lanyard and connector specifically allows such a connection F To any object which is shaped or dimensioned such that the snap hook or carabiners will not close and lock or that roll out could occur Figure 4 Inappropriate Connections 2 4 ANCHORAGE STRENGTH Structural anchorage points must be rigid and capable of supporting at least 5 000 Ibs 22 2 kN along the axis of the horizontal lifeline Anchorages must also support at least 3 600 Ibs 16 0 KN applied in all potential directions of
24. ted in section 5 4 BEFORE SYSTEM USE Step 1 Inspect all screws bolts and nuts Ensure they are securely attached and tight Check to see if any bolts nuts or other parts are missing or have been substituted or altered in any way Inspect covers housings guards etc Ensure they are free of cracks dents or other damage Step 2 Inspect metal components for rust or corrosion that may affect their strength or operation Step 3 Inspect the wire rope for rust corrosion broken wires or other obvious faults Inspect the synthetic rope for burnt broken threads or other obvious faults Inspect all carabiners and connectors securing the HLL assembly to ensure they are present and properly installed Inspect the sleeves at the end of the lifeline for damage such as cracks dents or distortion Step 4 Inspect the impact indicator at the end of the lifeline If the pin is broken the system has been exposed to an impact force The system must not be used if the indicator is broken See Figure 12 Figure 12 Impact Force Indicator Broken pin indicates impact force Step 5 Inspect the reserve lifeline payout The horizontal Figure 13 Extension Indicator lifeline has a 4 5 ft 1 4 m reserve at the end of the lifeline If a red band attached around the rope is visible at the housing end of the lifeline the reserve has been compromised Remove the unit from service The unit must be serviced by an authorized service center
25. ve the EZ Line HLL from service and contact an authorized service center for repair IMPORTANT Only DBI SALA or an authorized service center may make repairs to this equipment 6 0 MAINTENANCE SERVICING STORAGE 6 1 Periodically clean the exterior of the unit with water and mild soap solution Position the unit so excess water can drain out Clean labels as required Wipe off hardware with a clean dry cloth 6 2 Clean the lifeline with water and mild soap solution Rinse and thoroughly air dry Do not force dry with heat An excessive buildup of dirt paint etc may prevent the lifeline from fully retracting WARNING If the lifeline contacts acids remove unit from service and wash with water and mild soap solution Inspect unit before returning to service 6 3 Lifeline replacement and additional maintenance and servicing procedures must be completed by an authorized service center Authorization and a return number must be issued by DBI SALA Do not lubricate any parts Do not disassemble the unit See section 5 for inspection frequency 6 4 Clean and store body support and associated system components according to manufacturer s instructions 6 5 Store the unit in a cool dry clean environment out of direct sunlight Avoid areas where chemical vapors may exist Inspect the unit after extended storage 6 6 USER EQUIPMENT Maintain service and store each piece of user equipment according to its manufacturer