Home

PACSystems RSTi Network Interface and IO, GFK-2783

image

Contents

1. GFK 2783 March 2012 IMPORTANT PRODUCT INFORMATION READ THIS INFORMATION FIRST PACSystems RSTi Network Interface and IO Discrete Input Module ST 1114 AA ST 1124 AA ST 1214 AA ST 1218 AA ST 121F AA ST 1224 AA ST 1228 AA ST 122F AA ST 1314 AA ST 131F AA ST 1324 AA ST 1804 AA ST 1904 AA Discrete Output ST 2114 AA ST 2124 AA ST 221F AA ST 222F AA ST 2314 AA ST 2318 AA Modules ST 2324 AA ST 2328 AA ST 2414 AA ST 2424 AA ST 2514 AA ST 2524 AA ST 2742 AA ST 2744 AA ST 2748 AA ST 2852 AA Analog Input ST 3114 AA ST 3118 AA ST 3134 AA ST 3214 AA ST 3218 AA ST 3234 AA Modules ST 3424 AA ST 3428 AA ST 3444 AA ST 3524 AA ST 3544 AA ST 3624 AA ST 3644 AA ST 3702 AA ST 3704 AA ST 3708 AA ST 3802 AA ST 3804 AA ST 3808 AA Analog Output ST 4112 AA ST 4114 AA ST 4212 AA ST 4214 AA ST 4274 AA ST 4422 AA Modules ST 4491 AA ST 4522 AA ST 4622 AA ST 4911 AA O Bus NIU STXPBS001 AA STXPBS032 AA STXPBS132 AA STXPBS232 AA Modules STXPBS332 AA STXPBS432 AA STXPBS532 AA STXPNSO001 AA Specialty ST 5101 AA ST 5111 AA ST 5112 AA ST 5114 AA ST 5211 AA ST 5212 AA Modules ST 5221 AA ST 5231 AA ST 5232 AA ST 5351 AA ST 5422 AA ST 5442 AA ST 5444 AA ST 5641 AA ST 5642 AA ST 5651 AA System Modules ST 7008 AA ST 7108 AA ST 7108 AA ST 7111 AA ST 7188 AA ST 7241 AA ST 7408 AA ST 7508 AA ST 7511 AA ST 7518 AA ST 7588 AA ST 7641 AA Doc
2. annels 0 5Vdc 12 bit ST 3644 AA Al 4 Channels 0 5Vdc 14 bit ST 3702 AA Al 2 Channels RTD ST 3704 AA Al 4 Channels RTD Connector Type ST 3708 AA Al 8 Channels RTD Connector Type ST 3802 AA Al 2 Channels Thermocouple ST 3804 AA Al 4 Channels Thermocouple Connector Type ST 3808 AA Al 8 Channels Thermocouple Connector Type ST 4114 AA AO 4 Channelsl 0 20mA 12bit ST 4214 AA AO 4 Channels 4 20mA 12bit ST 4424 AA AO 4 Channels 0 10Vdc 12bit ST 4522 AA AO 2 Channels 10 10Vdc 12 bit ST 5101 AA High Speed Counter 1 Channel 5VDC 1 5MHz ST 5111 AA High Speed Counter 1 Channel 24VDC 1 5MHz ST 5112 AA High Speed Counter 2 Channel 24VDC 100Khz ST 5114 AA High Speed Counter 4 Channel 24VDC 50Khz ST 5351 AA SSI Interface 1 CH 62 5K 100K 125K 250K 500K 1M 2Mbps ST 5422 AA PWM Out 2A 24V Source 2 Channels 2 5Khz ST 5442 AA 2Ch PWM Out 0 5A 24V Source 2 5Khz ST 5444 AA PWM Out 0 5A 24V Source 4 Channels 2 5Khz ST 5641 AA 1 CH Pulse Out 0 5A 24V Source 20Khz ST 5642 AA 2 CH Pulse Out 0 5A 24V Source 20Khz ST 5651 AA 1 CH Pulse Out 0 5A 5V RS422 20Khz Operational Notes Subject Description IO module Loss of device fault occurs when When the Slice IO PROFINET Network Adapter module does not STXPNS001 PROFINET Network Adaptor is used without PNC The Network Adapter NET LED blinks RED indicating invalid have an IO module attached it will not communicate with the RX3i configuration and a Loss o
3. f device fault is logged in RX3i IO Fault table At least one IO module has to be present for the Network Adapter to establish the communication with RX3i PNC
4. r modules are power cycled together or the node is powered up following the sequence such that the power module farthest from the Network Adapter is powered up first For example in a node having modules as below STXPNS0014 10 Modules ST 7511 IO Modules ST 7511 1O Modules In the above system power cycle the STXPNS001 and the two ST 7511 modules together or power OFF the entire node and then power ON the second ST 7511 and then the first ST 7511 and then the STXPNSO01 RSTi PROFIBUS Network Adapter is unstable at baud rates less than or equal to 187 5kbps Continuous loss and addition of the IO node occurs DPV1 commands are not supported in this release for the PROFIBUS Network Adapters STXPBSxxx Important Product Information 3 GFK 2783 Modules Requiring Update Rate 2 32ms When Used with STXPNS001 GE Catalog No Description ST 3114 AA Al 4 Channels 0 20mA 12 bit ST 3118 AA Al 8 Channels 0 20mA 12bit ST 3134 AA Al 4 Channels 0 20mA 14 bit ST 3214 AA Al 4 Channels 4 20mA 12 bit ST 3218 AA Al 8 Channels 4 20mA 12bit ST 3234 AA Al 4 Channels 4 20mA 14 bit ST 3424 AA Al 4 Channels 0 10Vdc 12 bit ST 3428 AA Al 8 Channels 0 10V 12bit ST 3444 AA Al 4 Channels 0 10Vdc 14 bit ST 3524 AA Al 4 Channels 10 10Vdc 12 bit ST 3544 AA Al 4 Channels 10 10Vdc 14 bit ST 3624 AA Al 4 Ch
5. ult table In this situation if you try to clear the RX3i CPU user memory PME disconnects from the RX3i controller After the PME connection is lost if you try to reconnect to the RX3i CPU the RX3i PNC performs an auto reset To recover from this fault wait for the PNC to auto reset and the OK LED to glow solid green then clear the RX3i CPU user memory or power cycle the RX3i controller without battery Storing a valid configuration restores system operation without faults RSTi PROFINET Adapter receives a bus error when used with ST 5xxx ST 4xxx and ST 3xxx modules RSTi PROFINET Adapter STXPNS0O01 fails due to bus error when configured with certain ST 5xxx ST 4xxx and ST 3xxx modules Refer to Modules Requiring Update Rate 2 32ms When Used with STXPNS001 on page 3 for part numbers of the modules The failure occurs when the update rate is set to a value less than 32ms Reaction of the node to the bus error depends on the value of the parameter Reaction to bus error in STXPNSO01 parameter setting tab in PME To avoid this issue set the update rate to 32ms or above when any of the modules listed are configured with STXPNSO01 Slice IO node system power up sequence issue If the Network Adapter and ST 7xxx Power modules on the same Slice IO node are power cycled at different times the Network Adapter may power up in fault mode To recover from the fault power cycle the node such that Network Adapter and Powe
6. umentation Manuals PACSystems RSTi I O User Manual GFK 2745 PACSystems RSTi Network Adapter User Manual GFK 2746 Quick Guides RSTi Slice IO Discrete Input Modules GFK 2763 RSTi Slice IO Discrete Output Modules GFK 2764 RSTi Slice IO Analog Input Modules GFK 2765 RSTi Slice IO Analog Output Modules GFK 2766 RSTi Slice IO Power and Extension Modules GFK 2767 RSTi Slice IO High Speed Counter SSI PWM and Pulse Output Modules GFK 2768 RSTi Slice IO Serial Interface Module GFK 2769 RSTi Slice IO PROFIBUS Network Adapter GFK 2770 RSTi Slice IO PROFINET Network Adapter GFK 2771 RSTi PROFIBUS Network Adapter with Integrated IO GFK 2772 The most recent user documents are available on the Support website http Awww ge ip com support Indicates a trademark of GE Intelligent Platforms Inc and or its affiliates All other trademarks are the property of their respective owners Restrictions and Open Issues Important Product Information GFK 2783 Subject Description Clearing the RX3i controller memory when a configuration mismatch fault for a Slice IO node exists causes Proficy Machine Edition PME software to disconnect and the RX3i PNC001 to auto reset This fault can occur when an RX3i PNC module is connected to a Slice IO node that has a STXPNS001 PROFINET Network Adapter and IO modules If there is a configuration mismatch of the Slice IO node a loss of device fault is logged in the IO fa

Download Pdf Manuals

image

Related Search

Related Contents

Whirlpool GB2SHTXTB00 User's Manual  PAR 36 PAR 56 PAR 64 LED PAR user manual  Whirlpool Roper RAB4232DL0 User's Manual  Forward Bin Dumper - Cascade Corporation  DIT-IR Infrared Interface Module  Intel SSD Pro 2500 120GB  2 - G1SLE  benutzerinformation notice d'utilisation istruzioni per  AQUASMART Room Controller  Bedienungsanleitung  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.