Home

CTL-SYNC Owner`s Manual

image

Contents

1. citeu Verner CLASSIC EFFECT SYNCHRONIZER OW N E R S MAN UAL Congratulations on purchasing CTL Sync by Molten Voltage CTL SYNC is a programmable PedalBoard Classic Effect Synchronizer that connects the Control or Tap Input of classic effects and switches in sync with the incoming MIDI Clock at one of nine 9 musical ratios Key Features Synchronize your PedalBoard s Classic effects to MIDI Clock Works with numerous classic effects including the BOSS PH 3 Phase Shifter AW 3 Dynamic Wah and DD 7 Delay Works with any effect that allows connection of a remote tap footswitch Two 2 Simultaneous Switch Outputs Ratio controls multiply or divide the outputs against the incoming clock into one of nine 9 musical ratios Stores and recalls distinct Output Ratio for each output Simple to program toggle a switch Optically Isolated Outputs ensure 100 electrical isolation of audio and digital signals Compact design assists discrete modular PedalBoard construction Solid Professional Grade construction including Riveted Steel MIDI Jacks Molten Voltage technology allows remote synchronized self programming Robust 128 program storage questions MoltenVoltage com 2014 MoltenVoltage com All Rights Reserved v 1 2 Molten Voltage CTL SYNC Owner s Manual p 2 CONNECTING Plug in a separate or isolated 9 volt 2 1mm 100mA minimum tip negative DC Power supply into the DC9V jac
2. SYNC will always respond to an incoming MIDI Clock questions MoltenVoltage com 2014 MoltenVoltage com All Rights Reserved v 1 2 Molten Voltage CTL SYNC Owner s Manual p 5 To change the Output Mode and MIDI Channel have the PGM switch in the up position when powering on Switch the PGM switch down within 2 seconds The STATUS LED will blink in a pattern indicating the current Output Mode and MIDI Channel Output Mode MIDI Channel LED Blinking Pattern Both BOSS 1 LED off with 1 pulse on Both BOSS DEFAULT 15 LED on with 1 pulse off TAP 1 BOSS TAP 2 Inverted 1 LED off with 2 pulses on TAP 1 BOSS TAP 2 Inverted 15 LED on with 2 pulses off Both Inverted 1 LED off with 3 pulses on Both Inverted 15 LED on with 3 pulses off Turn the Ratio 1 Control F to select between the 3 Output Modes Full Left both BOSS normally closed switching Center 1 of each TAP 1 BOSS TAP 2 inverted Full Right both inverted normally open switching Review the manual for the device to be controlled to determine the correct output mode Turn the RATIO 2 Control E to select between MIDI Channel 1 and 15 Full Left MIDI Channel 1 Full Right MIDI Channel 15 Switch the PGM switch back up to store the Output Mode and MIDI Channel Note Changing Output Mode and MIDI Channel does not overwrite any stored programs Factory Preset Values e 1 1 Quarter Note Ratio e Both BOSS Outpu
3. k B Never power CTL SYNC using a daisy chained power supply that is also connected to audio effects A MIDI IN Jack B DC Power Jack C PGM Switch D STATUS LED E RATIO 2 Control F RATIO 1 Control G TAP 2 Output H TAP 1 Output MIDI Input Connect a standard 5 pin MIDI cable to the MIDI IN Jack A MIDI Clock CTL SYNC switches the TAP 1 and 2 Outputs relative to the incoming MIDI Clock Maximum MIDI Clock interval 2 5 seconds 24 bpm Minimum MIDI Clock interval 0 25 seconds 240 bpm Output Switching only occurs while MIDI Clock data is being received MIDI Start FA commands instantly reset both outputs questions MoltenVoltage com 2014 MoltenVoltage com All Rights Reserved v 1 2 Molten Voltage CTL SYNC Owner s Manual p 3 Program Change Messages CTL SYNC stores the Output Ratios associated with each of 128 Programs Programs are recalled upon receipt of MIDI Program Change messages on CTL SYNC s MIDI Channel default is 15 See below for information on Selecting MIDI Channel Upon receipt of a Program Change message the Output Ratios for that Program are recalled If MIDI Clock is being sent any new clock speed is used As long is MIDI Clock is flowing the outputs remain consistent and do not reset upon receipt of a program change To reset the outputs a MIDI Start command is required Note CTL SYNC also responds to Program Change messages sent using the runni
4. ng status data format TAP Outputs Using standard 1 4 mono cables connect CTL SYNC s optically isolated TAP 1 H and TAP 2 G Outputs to the CTL Control or Tap Inputs of the devices to be controlled The TAP Outputs will switch in sync with the incoming MIDI Clock The default is both TAP Outputs using normally closed switching BOSS style The outputs can also be configured so that the switching is normally open inverted from BOSS or one of each See below for instructions of changing the Output Mode Limitations of BOSS CTL and other Tap Inputs BOSS and other effects have varying limits on the minimum and maximum allowable switching speeds CTL SYNC can likely exceed those limits at its maximum and minimum values creating unpredictable results Other effects may have a noticeable time lag before adjusting to the switched tempo depending on how many taps are required to change the tempo Please refer to the owner s manuals for the devices controlled for more information questions MoltenVoltage com 2014 MoltenVoltage com All Rights Reserved v 1 2 Molten Voltage CTL SYNC Owner s Manual p 4 Ratio Controls The RATIO 1 F and RATIO 2 E Controls multiply or divide the Output Switching speeds relative to the incoming MIDI Clock The Output Ratios are based on nine 9 musical subdivisions sixteenth note 1 4 ratio eighth note triplet 1 3 ratio eighth note 1 2 ratio
5. quarter note triplet 2 3 ratio quarter note tap speed half note triplet 4 3 ratio half note 2 1 ratio whole note 4 1 ratio two whole notes 8 1 ratio As a result synchronized devices can switch at different yet complimentary rates The default Output Ratio is quarter note which corresponds to the knob pointing to the top of the pedal Sixteenth note is full left while two whole notes is full right Note Ratio changes affect only the current Program and are not stored unless the Program is saved as described in the next section Note CTL SYNC reads the position of the Ratio Controls on power up Note Whenever the ratio controls are not stable i e when they are moving or have recently moved the STATUS LED will turn off until they become stable again Each control will stabilize after approximately three 3 seconds of no motion Program Storage CTL SYNC stores the distinct Output Ratios for each of 128 programs Programs are stored by toggling the PGM Switch down then up again The STATUS LED will flash to indicate the program was successfully stored Programs can also be stored upon a self programming command from the Molten Voltage MASTER CONTROL or Molten Voltage TEMPODE MIDI Clock Injector Selecting Output Mode and MIDI Channel CTL SYNC offers 3 different Output Modes and can be set to respond to MIDI Program Change messages on MIDI Channel 1 or 15 Note MIDI Clock is not channel specific As such CTL
6. ronized Determine switching polarity required by referring to device s owner s manual and adjust CTL SYNC accordingly Make sure MIDI Clock and Ratio do not exceed the input limits of the device General Guidelines Keep MIDI cables as short as possible Long cables cause errors If you need more length consider using a MIDI repeater If you are daisy chaining MIDI devices the total MIDI cable length must be considered if any MIDI devices do not amplify the data signal Support questions MoltenVoltage com questions MoltenVoltage com 2014 MoltenVoltage com All Rights Reserved v 1 2 Molten Voltage CTL SYNC Owner s Manual p 7 Related Products e MASTER CONTROL MV 58 and MV 58B e TEMPODE the MIDI Clock Injector e MIDI Splitty MIDI Pedalboard Repeater Many more available soon Warranty Molten Voltage is proud of its products and warrants this unit for a period of two 2 years from the date of purchase to be free from defects in materials and workmanship under normal use and service as long as the unit is used with an approved power supply and consistent with these instructions Contact Service MoltenVoltage com regarding repairs Any user repair attempts void the warranty PROOF OF PURCHASE IS REQUIRED FOR WARRANTY REPAIRS Molten Voltage MIDI PedalBoard Devices Sturdy Scalable Simple streamline your sound DISCLAIMER Information contained in thi
7. s publication regarding device applications and the like is provided only for your convenience and may be superseded by updates It is your responsibility to ensure that your application meets with your specifications MOLTEN VOLTAGE MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED WRITTEN OR ORAL STATUTORY OR OTHERWISE RELATED TO THE INFORMATION INCLUDING BUT NOT LIMITED TO ITS CONDITION QUALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Molten Voltage disclaims all liability arising from this information and its use No licenses are conveyed implicitly or otherwise under any Molten Voltage intellectual property rights BOSS is a trademark of the Boss Corporation which company and trademarks are unrelated to Molten Voltage SIMI CTL Sync MASTER CONTROL MIDI Splitty TEMPODE NODE Tru Foot Molten Voltage Visionary Effects ReMute Sturdy Scalable Simple streamline your sound Design simple Design sublime and the future just showed up are all trademarks of Molten Voltage Legal MoltenVoltage com questions MoltenVoltage com 2014 MoltenVoltage com All Rights Reserved v 1 2
8. t Mode e MIDI Channel 15 Note the primary MIDI channel for the Molten Voltage system is MIDI Channel 15 MIDI Phantom Power CTL SYNC does not use MIDI Phantom Power questions MoltenVoltage com 2014 MoltenVoltage com All Rights Reserved v 1 2 Molten Voltage CTL SYNC Owner s Manual p 6 MIDI IMPLEMENTATION CHART Function Recognized Comment Note On X Note Off X Aftertouch X Control Change X Program Change O Only Program Changes on Channels 1 or 15 depending on selection recognized Channel Pressure X Pitch Bend X System Common X System Exclusive O Responds to Molten Voltage self program commands System Realtime O Only MIDI Start and Clock O YES X NO TROUBLESHOOTING Problem Solution CTL SYNC will not turn on Plug in 9 volt DC 2 1mm Tip Negative Power Supply Clicking or Noise Use a separate or isolated Power Supply for CTL SYNC Clock CTL SYNC is not receiving MIDI Make sure your other MIDI device is configured to send MIDI Clock Consult the User s Guide for that device If it cannot send MIDI Clock consider the Molten Voltage devices MASTER CONTROL or TEMPODE CTL SYNC not receiving MIDI Program Change messages Set your MIDI device to send MIDI Program Change messages on the same MIDI Channel as CTL SYNC see above regarding Selecting MIDI Channel Classic Effect is not synch