Home
Using the Commander Console
Contents
1. 12 The PowerTrack Dynamometer Care and Cleaning sioe Cera e pot pet e Pte 13 Changing Testing Pads 13 Using the Dynamometer ee 13 Manual Muscle Testing General Considerations Manual Muscle Testing Precautions 14 Manual Muscle Testing General Information 14 Manual Muscle Testing Accuracy 14 Grading Muscle Tests When Should a Muscle Test Be Graded 15 Grading with the Muscle Testing Dynamometer 15 Grading without the Muscle Testing Dynamometer 16 Commander Warranty One year Limited Warranty The Commander console and PowerTrack IITM dynamometer are designed to perform reli ably and to meet specifications In spite of diligence in manufacturing eliminating malfunc tions resulting from random component failure is impossible Therefore JTECH will at its option repair or replace the product with a new or reconditioned unit at no charge for a peri od of one year from the date of purchase In view of the varied conditions in which the unit will be used the Commander Console and PowerTrack II are sold as is and JTECH s responsibility does not go beyond the terms set forth above JTECH will not be responsible for medical expenses or any direct indirect or consequential damages arising from the use of
2. s PowerTrack II muscle testing systems the actual force values are automatically recorded so the need to grade every test is greatly reduced As a result tests conducted for purpos es like initial screenings and monitoring progress are not required to be graded In addition tests not graded during the examination or immediately after can be grad ed at a later date if necessary using the test values recorded on the worksheet According to the AMA Guides to the Evaluation of Permanent Impairment a mus cle test must be graded if it 15 to be used as part of an impairment rating Tests where the patient cannot exert force against the dynamometer or where the use of a force gauge is infeasible should also be graded to provide documentation of the test Grading with the Muscle Testing Dynamometer Grade 4 or 5 These grades are assigned if the patient can provide slight to full resistance against the dynamometer Patient moderately resists against the examiner If any resistance occurs then the patient has enough strength to provide resistance against the muscle testing dynamometer If the patient is too weak to provide any resistance grades 0 1 2 or 3 should be assigned based on test results obtained without using the dynamometer 2 Place the patient in the recommended position and conduct a test using the dynamometer Repeat for a minimum of three repetitions to ensure accuracy and repeatability Repeat the test for the opposit
3. test parameters are set they become the defaults for the console For example if you set the number of repetitions to three then the unit will test for three repetitions per side for every exam unless you change the default Default settings do not change when the unit is turned off or when an exam is deleted Defaults can only be reset manually Setting Defaults Three buttons are used when setting console defaults TEST CONT SETUP NEXT SELECT and REVIEW CHANGE The buttons function as follows TEST CONT SETUP Press this button to move through the console modes until Setup is displayed It is also used to exit Setup after setting parameters NEXT SELECT Use this button to advance through the test parameters REVIEW CHANGE This button changes the parameter setting TEST ALT Press this button until console is in Setup mode After parameters are set use this button to exit back to Test mode this button to advance through parameters CHANCE When a parameter is displayed use this button to change the default setting Adjustable Defaults The PowerTrack Commander console allows you to control the following default parameters THRESHOLD This setting determines the amount of force that must be exerted against the dynamometer before the console begins recording data This setting is used to avoid inadvertently beginning a test It can be set at 1 3 5 10 or 20 pounds TEST Controls the nu
4. the test number on the work sheet or chart TEST 2 REP RIGHT Neck Flexion ILL 3 ___ Neck AL Flexion 4 Shoulder Flexion In this example the test number on the display corresponds to the pre printed test number on the worksheet This method eliminates the necessity of writing the test number on the worksheet before or during the exam as with the Sequential Testing Method Also when using this method with Commander Downloader software the names of the muscle groups are automatically assigned to the tests Helpful Hint You should be careful to select the proper test number before starting a test and be extremely careful not to inadvertently continue with the next automat ic test in the series If you inadvertently begin a test at the next test number instead of the worksheet number because of Automatic Indexing delete the test by press ing REVIEW and holding it while you press Redo Advanced Console Features Press REDO to test the last repetition again This feature is helpful if the current test was started inadvertently was done incorrectly or was for practice Redo a test If after reviewing exam results you determine that a test all right and left repetitions needs to be redone press REVIEW Once in Review mode press NEXT until the correct test number is displayed Press and hold REVIEW and press REDO Repeat the test Important Note When us
5. this product JTECH shall in no way be liable loss of revenue or profits resulting or alleged to result from use of this product THIS WARRANTY IS MADE EXPRESSLY IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING AN IMPLIED WARRANTY OF MER CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE UNDER NO CIR CUMSTANCES SHALL JTECH BE LIABLE FOR ANY DIRECT INDIRECT INCI DENTAL OR CONSEQUENTIAL DAMAGES THE REMEDIES SET FORTH IN THIS WARRANTY SHALL BE THE ONLY REMEDIES AVAILABLE EXCEPT AS SPECIFICALLY PROVIDED BY STATE LAW NO PERSON HAS ANY AUTHORITY TO BIND JTECH TO ANY REPRESENTATION OR WARRANTY EXCEPT AS SPECIF ICALLY SET FORTH HEREIN To have your Commander or PowerTrack II repaired 1 Contact JTECH Customer Service and describe the problem After receiving a return authorization number return the product to JTECH including all acces sories postage paid and insured to JTECH JTECH is not responsible for damages or losses incurred in shipping 2 Submit proof of purchase and date 3 Include a brief explanation describing the problem Features and Benefits PowerTrack II M Dynamometer Produces very stable make or break tests Reduces roll over and tilting with a 1 8 high ergonomic design that fits in the palm TM Uses snap in place Quick Connect system for changing accessory pads which is much faster than old fashion screw on methods Maintains accuracy even when force is applied off center with exc
6. 2 REP 1 RIGHT TEST 2 REP 2 RIGHT etc Helpful Hint If unilateral testing is required the right side can be tested and the left side skipped by pressing the NEXT button or the right side can be skipped by pressing NEXT and testing the left side Alternating Sides Repetition Order When Test Alt mode is displayed the rep etitions alternate between right and left side as follows TEST 1 REP 1 RIGHT TEST 1 REP 1 LEFT TEST 1 REP2 RIGHT TEST 1 REP 2 LEFT TEST 2 REP 1 RIGHT TEST 2 REP LEFT etc This method can be used if submaximal effort is indicated By mixing up the left and right side routine the subject may have a more difficult time repeating the results on each side as indicated by the coefficient of variation Testing Methods The Commander console can store up to 40 tests in memory complete with data for all repetitions and statistics In order to easily record multiple tests the Commander uses Automatic Indexing M This method automatically indexes the display to the next test in the series without requiring you to press any buttons For example after completion of all right and left side repetitions of test 1 the display indexes to TEST 2 REP 1 RIGHT NOTE After completing a test Commander prevents inadvertent deletion of tests previously stored in memory by indexing to the next test not completed For example if test 2 was completed previously after test 1 is completed Commander will skip tes
7. Powerrack II COMMANDER User s Manual Written by Tracy Livingston David Bernardi and Michael Carroll Published by JTECH Medical 470 Lawndale Drive Suite G Salt Lake City UT 84115 801 478 0680 www jtechmedical com JTECHwenicat Copyright 2004 JTECH Medical All rights reserved PN 680 Contents Commander Warranty sues ssp Rp ERR RR ERU ER e 1 To have your Commander or PowerTrack repaired 1 Features and Benefits 0 0 0 ree 2 Check Your System use dede aes Me a ee oy recte 3 Proper i osse eee RS EUER 3 Calibration qu SEE RAE aah RA eS 3 Battery Life cua ue ERR ae eRe SS EA UE IDEE SEE Ee 3 Available Upgrades ssi ir e e 4 Wrist and Desktop Use of the Console 4 Using the Commander Console Conventions oues DES RR Ga Ap re RA 5 ONO Button 2 22 0 5 2 0 susie echoed eosin gle Tei we ed Aa AU RE IET 5 Setup Mode eee oe S Goethe APIS e p Rp anges 6 Test and Test Alt Modes rh 7 Testine Methods c scere EMI ER ERE EU RSEN Eee pis 8 Advanced Console Features 10 Reviewing an Exam i sio gta Cx oed Peg 10 Statistics Definitions 12 Deleting an Exam MESES TEE e ee ee 12 RepottS oec Be RE edt qub eec Do reel d bcd
8. ample testing elbow flexion elbow exten sion wrist flexion and wrist extension could comprise one exam On Off Button Press the ON OFF button once to turn the console on press it again to turn the console off Exams stored in memory are not erased when power is turned off Holding the ON OFF button down for two seconds clears all stored exams The console shuts off automatically after four minutes of inactivity Note Make sure no force is applied to the dynamometer when turning the console on When the console unit is turned on it will activate in either Test mode Review mode depending on whether an exam is stored in memory If no exam is stored in memory the console will activate in Test mode ready for test 1 The active mode in this case TEST is displayed in this area Test and repetition numbers are shown here Side being tested is displayed on this line Real time force on dynamometer can be shown in pounds or newtons Testing Mode If an exam is in memory when the console is turned on Commander activates in Review mode From this point you can review exam data change to Test mode to finish testing or delete the exam Setup Mode Testing Defaults The Commander console enables you to use the Setup mode to control a variety of test parameters such as the testing threshold number of tests number of repeti tions per test and force readings in pounds or newtons Once
9. e side 4 Ifa strength deficit greater than 15 exists bilaterally when tested with the dynamometer the weaker side should be assigned a grade 4 As noted earlier a grade is required if the test is to be included in an impairment report Grading may be skipped if all that is needed is the bilateral strength comparison for showing progress justifying treatment or determining the injured diseased nerves Grading without the Muscle Testing Dynamometer If the subject does not have sufficient strength to resist against the force gauge or a force gauge test is infeasible then the following grading system can be used Grade 4 5 Good Normal Moderate to full resistance against the examiner Grade 3 Fair Partial to complete motion against gravity Grade 2 Poor Partial to complete motion with gravity removed Grade 0 1 Zero Trace No contraction to slight contraction
10. e will beep and turn off indicating data has been erased Note test default values will be retained Reports Muscle testing reports from PowerTrack II Commander can be created several ways 1 Use the supplied worksheets to create hard copy documentation 2 Optional Easy Docs Plus Software from JTECH Medical is an efficient way to generate reports using your PC With Easy Docs Plus you enter muscle testing data into the software using your keyboard Easy Docs Plus then maintains the data calculates statistics produces progress bar graphs generates data reports and allows you to print narratives from Microsoft Word Manual Muscle Testing General Considerations Manual Muscle Testing Precautions The following are general guidelines to minimize risk of injury to the patient Please note that these guidelines are not comprehensive because covering all possi ble conditions would be impossible Therefore final responsibility for the risk of injury to the patient lies with the examiner 1 Force increase should be gradual 2 Patient should be CLOSELY observed for any evidence of pain The test should be stopped immediately if this occurs Manual Muscle Testing General Information Manual muscle testing or grading should be performed when neurological problems at the nerve root or peripheral nerve are suspected or if disease or disuse affects the muscles Manual muscle testing can help identify specific nerve motor funct
11. he optional Tracker Impairment Software the sys tem automatically calculates motor deficit impairments from muscle testing results For more information on upgrades contact your JTECH sales representative or call JTECH at 1 800 985 8324 or 1 801 478 0680 Wrist and Desktop Use of the Console The PowerTrack II Commander system comes equipped with two cords for con necting the dynamometer to the console unit The short cord is used when the Commander console is strapped to the examiner s forearm The longer cord is used when the Commander console is placed on a desktop or left in the case during test ing The cords connect to the console and dynamometer with telephone jack plugs To remove a cord press down on the cord jack s plastic release lever and slide the end out of the receptacle When installing a cord make sure the jack snaps securely into place NOTE f a cord is damaged or lost do not attempt to replace with a standard tele phone cord as the wiring is not the same Contact JTECH Customer Service for the correct replacement cord Using the Commander Console Conventions This manual adopts the following convention throughout Test Refers to one strength assessment that may include multiple repetitions and comparisons between the right and left side For instance testing elbow flexion with three repetitions for the right side and three repetitions for the left side is one test Exam Refers to multiple tests For ex
12. ing REDO for a test the entire test including repetitions for the right and left side are deleted and must be redone Review last repetition To review the measured force for the last repeti tion press REVIEW after the repetition is complete To review other statistics associated with the test continue pressing REVIEW and the display will scroll through all available statistics To continue testing with the next repetition press TEST CONT To erase the repetition and start over press REDO Deleting a test Press REVIEW then press NEXT until the correct test number is displayed While holding the REVIEW button down press Redo The entire test including all right and left side repetitions will be deleted OOO OHO OOD rs eviewing an Exam An exam can be reviewed at any time either during testing or after by pressing the REVIEW button The last completed repetition will be dis played To review other tests within the exam press NEXT to advance to the next test with recorded data When advancing through tests the Commander display shows the test number with the right side repetition To see left side repetitions and additional statistics press REVIEW OG Statistics To scroll through and review all the statistics for the displayed test continue press ing REVIEW In the following example the statistics for test 4 are displayed in the order they wi
13. ion Bilateral testing indicating a weakness in several muscles may further substantiate disease or injury involving nerve roots or peripheral nerves as long as disuse or disease of the fibers of the muscle or disorders of the higher levels of the central nervous system are ruled out Manual muscle testing should never be used alone to diagnose but should be used in conjunction with other diagnostic testing tools such as the Dualer dual inclinom etry system or Commander Algometer pain pressure testing If a rehabilitation pro gram is initiated bilateral manual muscle testing should be completed at periodic intervals along with other diagnostic testing to document treatment efficacy Manual Muscle Testing Accuracy General rules must be followed to insure repeatability and accuracy when using the PowerTrack II manual muscle tester 1 If testing bilaterally the muscles and or tendons that normally cause the motion should be palpated bilaterally to help identify substitution by muscles other than the prime movers Adjust patient stabilization or position until substitution is eliminated If substitution continues document the nature of the substitution 2 The lever arm length between the attachment point of the muscle and the PowerTrack II dynamometer must be the same between repetitions and sessions Make sure the unit is placed at the same location for each repetition and test For multiple repetitions better accuracy is achieved if the u
14. ll appear by pressing REVIEW For this example the number of repetitions was set at two TEST REVIEW REP RIGHT JIU TEST H REVIEW REP 2 RIGHT LBS A Maximum Force Repetition 1 Right Side Maximum Force Repetition 2 Right Side TEST Lf REVIEW REP LEFT LULI Maximum Force Repetition 1 Left Side TEST REVIEW LEFT ar a CV Right Side TEST 4 REP 2 LEFT IT I Maximum Force Repetition 2 Left Side CV Left Side 1D Nb 4o Nb a TE ST M REVIEW Bilateral Deficit Left Side LEFT DEFICIT After all statistics have been selected the dis gt um play circles back to the beginning Selecting the next test to review To view the next test press NEXT The display indexes only to test numbers with data Statistics Definitions LBS In Test and Test Alt modes LBS displays force against the dynamome ter in real time In Review mode LBS shows maximum force on dynamometer for the displayed repetition CV The coefficient of variation for all the repetitions for the indicated side using the n 1 method Deficit Bilateral deficit indicating weakness of one side compared to the other Deleting an Exam To erase an exam turn the Commander console on then press and hold the ON OFF button for a minimum of two seconds or until the unit reactivates When the button is pressed unit consol
15. lusive Axis Compensation smart load cell Guarantees 99 force accuracy over the entire test pad area compared to other products with off center force accuracy from 94 96 Call JTECH for accuracy report details Includes both round and curved test pads Commander Console Easy to read 2 diagonal LCD Operates during exams either as a wrist unit or as a desktop system when using the included longer cable Gathers stores and analyzes up to 40 bilateral muscle strength tests including up to four repetitions per side Calculates CV and maximum force for each repetition Documents outcomes assessment with the automatic bilateral deficit analysis Helps determine consistency of effort in workers compensation and FCE exams Test now record later because the exam is stored in memory even when Commander is turned off Automatic audio prompts examiner for the next test in the series Measures up to 125 pounds for very strong performers Battery powered for portable operation Test protocols can be customized according to number of tests starting force newtons pounds and number of repetitions Check Your System Your PowerTrack II Commander system should include the following parts Commander Wrist Unit Round Pad PowerTrack Il Dynamometer Curved Pad e Short Cord Testing Chart Long Cord e Worksheets Make sure the serial number on the PowerTrack II located under the testing pad matches
16. mber of tests available for an exam The console automati cally goes into Review mode when the number is reached It can be set from 5 40 in increments of five REP Sets the number of repetitions per side per test It can be set from 1 4 A minimum of two repetitions is required for CV calculations LBS N This parameter controls whether force readings are in pounds or newtons Test and Test Alt Modes Tests are conducted using either the Test or Test Alt modes How the modes are used is described below To conduct a test apply pressure on the dynamometer Test recording begins when the default threshold force is exceeded A test ends when force on the dynamome ter drops back below the threshold The display then indexes to the next repetition in the series After all repetitions for a test are completed the display indexes to the next sequential test number Continue testing with this method until all tests are recorded in memory Repetitions for a Test The Commander console can record up to four strength repetitions per side for each test The repetition order is selected by either of two methods Same Side Repetition Order When Test mode is displayed the unit prompts for all right side repetitions first then all left side repetitions For example if the default is two repetitions the test sequence in Test mode is TEST 1 REP 1 RIGHT TEST 1 REP2 RIGHT TEST 1 REP 1 LEFT TEST 1 REP2LEFT TEST
17. nit remains placed on the body during all repetitions 3 Ensure the starting point for breaking action is at the same range of motion position for each test and repetition This is necessary because of the wide vari ations in force the prime movers can oppose depending on the starting point of breaking action 4 Determine the plane of motion of the segment and ensure that the PowerTrack II dynamometer is not sideways or off axis to this motion Additionally apply force in the direction of motion 5 Always build up resistance smoothly until the position is broken In general the break should occur within 2 3 seconds Prolonging the time to break may intro duce fatigue Shorter breaks are at higher risk of re injury or may not allow for buildup of maximum contraction For difficult to break segments two hands may be required Grading Muscle Tests Traditionally muscle testing uses a grading system for documentation and standard ization In the traditional system muscle test grades range from 4 5 Good Normal to 0 1 None Slight Contraction With the introduction of the PowerTrack II man ual muscle tester and the JTECH s IsoTrack isometric testing station the system has been modified slightly to encompass the additional diagnostic data available When Should a Muscle Test Be Graded Using the traditional subjective method of muscle testing every test needed to be graded just for the purpose of documentation With Commander
18. ry life The console will automatically shut itself off after four minutes of inactivity NiCad batteries can be used however the active battery life will be reduced to approximately eight hours or less When using a NiCad battery completely drain the battery before recharging to prevent memory in the battery that will further reduce battery life Available Upgrades The PowerTrack II can be used with the following upgrade products Easy Docs Plus Software Transfer Commander test data to you PC with this key board entry software Easy Docs Plus Software maintains your test data along with additional patient data test data from other devices such as inclinometers goniometers and static lift gauges and results from your favorite questionnaires With Easy Docs Plus you can quickly and easily create cutting edge data and narra tive reports Tracker Upgrade Package PowerTrack II comes ready to plug into the leading Windows based musculoskeletal evaluation software package The upgrade package includes the Tracker Interface Box for connecting to PC The PowerTrack IITM dynamometer plugs into the PowerTrack II port of the Tracker Interface Box without any modifications Tracker software automatically records test results with real time force curves analyzes statistics charts comparisons to previous tests works seamlessly with other Tracker diagnostic devices and outputs data in a com prehensive report format With t
19. t 2 and index to test 3 Sequential Testing Method This method always begins with test 1 using Automatic Indexing to proceed from test 1 to test 2 etc Mark the muscle groups on the exam worksheet with the corre sponding test numbers from the display For example a muscle testing exam is com TEST Z TEST pleted in the following order elbow flexion RIGHT elbow extension and shoulder abduction Before starting the exam 1 is placed on the elbow flexion line of the worksheet 2 on elbow extension and 3 on shoulder abduction Then either during the test or after test data for the test number on the Commander unit is recorded on correspon ding line of the worksheet This method facilitates documentation during exams by this example test 2 would corre allowing you or staff to complete the work spond to elbow extension on the sheet after the exam is finished worksheet Helpful Hint Since the display indexes past old tests stored in memory this method is recommended only if all previous tests have been erased Assigned Testing Method This method uses the default test numbers assigned to the test on the worksheet and flip chart The assigned numbers on the worksheet and chart correspond to the test numbers selected on the Commander console Therefore Automatic Indexing should not used with this method Instead use the NEXT button to select the test number on the Commander unit that correspond to
20. the serial number on the Commander Console If these numbers do not match call JTECH Customer Service Proper Care With proper care your new PowerTrack Commander will provide many years of worry free use Do not immerse the dynamometer or the console in water place in an autoclave or sterilize with harsh disinfectant To clean the housings wipe with a soft non abrasive cloth moistened with clean water To clean the display use a non abrasive dry cloth Do not use cleaners Avoid dropping or banging the instrument or console against hard objects Do not stand on apply more than 125 Ib or use the dynamometer for anything other than manual muscle testing Failure to follow these policies will void the warranty Calibration To ensure accuracy the PowerTrack II and Commander console have been factory calibrated with weights traceable to the National Institute of Standards and Technology When turned on the Commander console automatically zero calibrates itself Therefore make sure the dynamometer test pad is turned up and no force is being applied when the Commander console is turned on Any force applied to the dynamometer when the console is turned on will become the zero value and will result in inaccurate force readings Battery Life The Commander console uses a standard 9 volt alkaline battery The estimated bat tery life is 28 hours of operation The Commander console should always be turned off when not in use to maximize batte
Download Pdf Manuals
Related Search
Related Contents
Guía sobre riesgos laborales y medidas preventivas Industrial Air CP1580325 Instructions / Assembly patrimoine - Communauté d`agglomération du Boulonnais VW Alpha Europa Philips DLN1734 Trendnet N600 Burnham 4NL-W Coal Ratings ST88 User Manual - Livewire Connections Ltd boom! audio amp and speaker relay service kit - Harley Copyright © All rights reserved.