Home

the CrestDiag® Manual

image

Contents

1. PAN LEFT y LI Pulse High Pulse Low bied PAN RIGHT EE ELE Notification History on E Enable Notifications Clear History Refresh J ABC TANDBERG CAMERA RX Time 03 642 String ABC TANDBERG CAMERA TX Time 03 682 String PAN LEFT LI Time 10 588 Value 0 UU PAN RIGHT Time 10 869 Value 0 8 TANDBERG CAMERA RX 1 48 TANDBERG CAMERA TX amp C 4 Watched Signals The Watched list has an icon associated with each signal indicating what type each signal is associated with You can press edit on the tab to remove the signals from the watched list This way you won t have to search through the larger list to find the one you want to remove Deleting will only delete from the Watched list not from the signal type lists When you Enable Notifications you will see the known status of each signal show up in the notifications history list Pressing the signal in the watched list or the notifications list will bring up the appropriate stimulation controls for that signal These controls will allow you to change the signals values so you can debug your program If you need to debug signals that are found in your SIMPL modules go to the settings application on the iPad and find the CrestDiag application Then turn on the Load SIMPL Module Signals settings You will have to disconnect and reconnect in order for the module signals to be displayed iPad Settings ka Notifica
2. PAN SPEED Se mt PAN LEFT Time 52 060 Value O TANDBERG CAMERA RX dd PAN POSITION VV Time 52 193 Value 0 TANDBERG CAMERA TX Mili PAN RIGHT Time 52 246 Value 0 PAN_SPEED Time 52 300 Value 6 C TANDBERG CAMERA RX Time 52 677 String TANDBERG CAMERA TX Time 52 742 String PAN POSITION Time 52 904 Value 1 PAN POSITION Time 15 908 Value 38665 PAN POSITION Wi Time 37 676 Value 127 ST Watched Signals The decimal value can be any value from 0 65535 followed by the small d character The signed value can be any value from 32768 32767 followed by the small d character The Analog data format that is displayed in the Notification history list is set via the Settings Application Your choices are 1 Hexadecimal 000h ffffh 2 Percentage 0 100 3 Decimal Od 65535d 4 Signed 32768 32767 CrestDiag Support You may email mobile apps controlconcepts net in order to get support for this application Please send any enhancement ideas you may have All are welcome Thank you for purchasing this software CrestDiag support team
3. 52 677 String ABC TANDBERG CAMERA TX Time 52 742 String PAN POSITION Time 52 904 Value 1 Wi PAN POSITION Time 15 908 Value 38665 PAN POSITION Time 37 676 Value 127 amp C 4 Watched Signals Once you select a String signal from your watched list or from the notification history list you will see the String control display at the top of the detail view section Using the same Crestron String syntax you use in your programming you can enter in a String message to be assigned to that String signal when you press Send You do not need double quotes around your string data if you add them they will be ignored The String data format that is displayed in the Notification history list is set via the Settings Application Your choices are 1 ASCII hex 2 Hex 3 ASCII Printable Characters only Analog Signals iPad Watched Signals Ka Disconnect Q ET UU PAN LEFT dd PAN POSITION Mili PAN RIGHT W PAN_SPEED ER d TANDBERG CAMERA RX TANDBERG CAMERA TX VE Watched Signals 12 05 PM Signal Control dt Signal Name WAY PAN POSITION Current State La Notification History PSM Enable Notifications Clear History Refresh J nT PAN LEFT Time 52 060 Value 0 PAN POSITION W Time 52 193 Value 0 rt PAN RIGHT Time 52 246 Value 0 PAN_SPEED Time 52 300 Value 6 ABC TANDBERG CAMERA RX Time 52 677 String C TANDBERG CAMERA TX Time 52
4. 3 Series controller allows multiple programs to be loaded and running at the same time The SIMPL directory contains additional directories They all start with App make sure you put your signal file in the appropriate directory that is associated with its correct program 9 38 AM E uA ER TEN Hide To mobile apps controlconcepts net Signal File April 18 2011 9 28 AM Mark as Unread ca Open in CrestDiag demo sig 12 2 KB EI iPad Email client with signal file as an attachment Will open CrestDiag an automatically will select the email attached signal file You will also notice it is also now in the CrestDiag document directory Summary Info Apps Music Movies TV Shows g leg Mocha VNC Lite __ Business fs R m pese vj Automatically sync new apps Select apps to be installed on your iPad or drag to a specific home screen Drag to rearrange app icons or home screens File Sharing iTunes Store The apps listed below can transfer documents between your iPad and this computer Q Ping Purchased Apps CrestDiag Documents Purchased on i Tug i 4 8 11 8 30 PM Purchased on J CrestDiag emo sig 8 11 8 Purchased on J DEVICES vicar oOo JJ Music H Movies C TV Shows D Books GENIUS E Genius 88 Genius Mixes amp And It Stoned Me 8 Busted Stuff 8 Can t You See Es Free Bird L Save to LZ Let It Grow amp Midnite Cruiser E My Way Es Share
5. 357 String x81 x09 x06 x12 xff Watched Signals Once you select a Digital signal from your watched list or from the notification history list you will see the Digital control display at the top of the detail view section Pressing Push will set the digital signal high for as long as you hold down the Push button Releasing the button will cause the signal to go low Pressing Set High will set the signal high and will keep it high until either the programming or another control is selected to change its state Pressing Set Low will set the signal low and will keep it low until either the programming or another control is selected to change its state Pressing Pulse High will pulse the state high than return it to the low state after a short period of time Pressing Pulse Low will pulse the state low than return to the high state after a short period of time String Signal iPad gt 12 06 PM Watched Signals Ka Disconnect Q Signal Control E 5 Signal g Siring Data TANDBERG CAMERA RX x03Test x02 it PAN LEFT Send VY PAN POSITION Notification History i i PAN RIGHT BET Enable Notifications Clear History Refresh Wi PAN SPEED mt PAN LEFT m Time 52 060 Value 0 TANDBERG CAMERA RX PAN POSITION Time 52 193 Value 0 TANDBERG CAMERA TX Mili PAN RIGHT Time 52 246 Value 0 PAN_SPEED Time 52 300 Value 6 ABC TANDBERG CAMERA RX Time
6. 742 String dd PAN POSITION VU Time 52 904 Value 1 Analog signals stimulate controls will allow you to enter in the analog value in four formats hexadecimal decimal percentage and signed decimal Hexadecimal can be any value starting from 0000 ffff followed by a small h You must have 4 digits in front of the h character iPad 12 05 PM Watched Signals Eat Disconnect Q Signal Control Signal Name WS W PAN POSITION 59 _ Send UU PAN LEFT l Current State 38665 Y y PAN POSITION UU PAN RIGHT Wi PAN_SPEED EC Notification History on Enable Notifications PAN LEFT Time 52 060 Value O PAN POSITION Time 52 193 Value 0 PAN RIGHT Time 52 246 Value 0 PAN_SPEED Time 52 300 Value 6 TANDBERG CAMERA RXS Time 52 677 String TANDBERG CAMERA TX Time 52 742 String PAN POSITION Time 52 904 Value 1 PAN POSITION Time 15 908 Value 38665 es L Clear History Refresh j TANDBERG CAMERA RX TANDBERG CAMERA TX El 8S El E El gt c el Be ST Watched Signals Percentage can be any value from 0 100 followed by the percentage character iPad 12 05 PM Watched Signals Ka Disconnect Q Signal Control p Signal Name EF WV PAN POSITION i i PAN LEFT Current State 127 Y Y PAN POSITION Notification History i i PAN RIGHT BET Enable Notifications Clear History Refresh Wi
7. the Land Capacity 14 03 GB Apps Other Free 0 04 GB 0 24 GB 13 8 GB iTunes File Sharing showing demo sig as a CrestDiag document Drag and drop signal files into the Document directory to get the files on to your iPad va AT amp T 12 13 PM a aL AT amp T S 12 13 PM i Dropbox Signal Files Fx en WOO ae tee Y Q Q TA Getting Started pdf camSig sig 225KB modified 22 minutes ago 8 5KB modified 15 minutes ago iii Photos large sig 416KB modified 2 minutes ago L4 Public L1 Signal Files Dropbox sat AT amp T e 12 14 PM Signal Files large sig RLSIG0001 5 EXIT_YES_WITH_DISPLAY_ON ees 1 3 1 0000124CL SHUTDOWN BARGRAPH ON S 1 3 1 0000125106 EXIT YES WITH DISPLA Y OFF I S 1 3 1 0000124DM INIT FULL ON S 1 3 1 00001252R SHUTDOWN TIME REMAIN ING SEC OFF S i i 1 3 1 00001253S0 SHUTDOWN BARGRAPH OF F S 1 3 1 00001254T INIT FULL OFF S 1 3 1 00001255U9 SHUTDOWN TIME REMAIN ING SEC ON S 1 3 1 00001250P SHUTDOWN BAR AT 100 S 1 3 1 0000124F03 EXIT_YES_WITH_DISPLA Y ON S 1 3 1 0000124AJ4 EXIT YES WITH DISPLA Y OFF S 1 3 1 0000124BK CLEAR SHUTDOWN BAR S 1 3 1 0000124EN EXIT YES M S 1 3 1 0000124915 EXIT YES WITH DISPLA Y ON I S 1 3 2 00001255 7 CrestDiag Cancel SHUTDOWN_BARGRAPH_ON Dropbox Cloud services application prompting to open CrestDiag O with signal file from list Ip oe View Tools Window Help c Ext jc m
8. C re stD lag by Control Concepts User Manual Date 7 1 2011 Version 1 1 Table of Contents VIVO NICS ON 3 an EN 3 Gore t tere rene enn rere ncn ee ee ee ee eee ee ce ee 11 PaO O eee eee 12 D puggine elt E E 14 SEO atl DEn CET 17 Digital SIS ANS E E E ust unco de E E matia nes ania E E DEEST EE 17 SETI SU Sie MR 18 ARAOR SIBIIdIS ege 19 Cre aE e ee e M c 21 Introduction CrestDiag is an iPad application that helps you diagnose Crestron 2 Series and 3 Series control systems In order to diagnose the system you will need to get the most recent signal file that was generated when you compiled the code on to your iPad You will also need to make sure your iPad can connect to the controller that you wish to debug This manual will explain several methods for getting the signal file on to your iPad It will also show you how to select the signals to debug and how to stimulate the signals to debug your programming This program performs some of the same features as Crestron s own debugger program found in Crestron s Toolbox applications Signal Files Signal files are created when you compile the Crestron program using Crestron s SIMPL Windows programming tool You can find them in the same directory that the compiled program is l
9. ans you can press and add it to your favorite list Favorites Favorites are a way for you to manage the controllers that you use every day You will be allowed to store virtually an unlimited amount of controllers in your favorite list 2 13 PM Favorites Favorite Connection List Edit 192 168 187 160 Work ER Favorites To add a controller to your Favorites list press the Plus button that is associated with an IP Address from the search section on your connection page This will automatically switch CrestDiag to the Favorites page and prepare the form to add this controller to your list You can also press the Add button on the Favorites page manually enter in the IP Address and name than press save 11 36 AM Favorites Favorite Connection List 192 168 187 160 Work d Favorites To edit the name associated with a saved controller simply press the entry in the table and the edit form will display manually change the name and press save To delete one or more controllers from your list press the Edit button Then select each controller from the list that you wish to delete Pressing the Connection icon associated with the Favorite controller will automatically select the controller for connection and switch you to the connection page Debugging Your Program Once connected to your controller it is really best to hold the iPad in Landscape mode You will no
10. ectory If you have the upload switch enabled it will attempt to find the signal file in that program s directory Connection Once you have the signal file on your iPad you now can make a connection to the controller The iPad must be connected to WIFI in order to connect to the controller on the local network CrestDiag has a little search glass on the connection page this will attempt to find all the Crestron controllers that are on your local subnet 2 14 PM CrestDizc by Control Concepts Inc one Signal File OFF Turn ON to upload Signal File from Controller Currently Selected Signal File E demo sig Press to choose Signal File C IP Connection IP Address 192 168 187 160 192 168 187 162 192 168 187 164 Connect sl T Connections Selecting a controller from the searched list will assign it to the connection text box and close the search list Since some networks are large and complex your controller may not actually show up in the list Scroll through the list too see all controllers CrestDiag has found If your controller does not show up in the list this does not mean you cannot connect to it just means that more than likely it is not on the same subnet Go ahead and manually enter in the controller s IP address and press Connect The controllers with the Star next to the IP address indicate that the IP address is already in your favorite list The IP addresses with the Plus me
11. file and directory structure of the 3 Series controller Once the signal files are on the controllers in the appropriate directory you can turn on the upload switch and connect to the controller CrestDiag will upload and read the signal file and ready it for your use 2 14 PM CrestDiac by Control Concepts Inc om Signal File OFF Turn ON to upload Signal File from Controller demo sig r4 Currently Selected Signal File demo sig Press to choose Signal File IP Connection IP Address ey Connect Fei Connections Opening the file list using the signal file controls you will see all the signal files that are stored in CrestDiag s Document Directory 2 15 PM CrestDiag by Control Concepts Inc ome Signal File ON Turn ON to upload Signal File from Controller IP Connection IP Address 192 168 187 160 ey Connect Connections Turning on the upload switch will attempt to upload the signal file from the controller s SIMPL windows directory 2 e J 1 dafCE by Control Concepts Inc signal File gt upload Signal File from Controller IP Connection Pick program to debug Program 1 Lighting Program 2 A V Disconnect When connecting to a 3 Series controller if more than one program has been loaded it will prompt you to choose which program to debug This is why it is important to put the signal file in the correct App dir
12. i us b5s id maemmm uss s E BB Internal Flash eme E 3 1 o CH DISPLAY C Program_Boot_Data CH HTML C TANDBERG PrecisionHD Camera Direct Control v1 0 Demo Program bin fe MAILBOX L TANDBERG PrecisionHD Camera Direct Control v1 0 Demo Program dip 9 3 SETUP C TANDBERG PrecisionHD Camera Direct Control v1 0 Demo Program dsc SS SIMPL H TANDBERG PrecisionHD Camera Direct Control v1 0 Demo Program rte cl SPLUS C TANDBERG PrecisionHD Camera Direct Control v1 0 Demo Program sig oo SYS C Manifest H E USER m Aj Ready 1 File View Window Help SHXO i SRILMEDOM eHODABEAIAVOH H Sa Internal Flash Name Sz Tme GMD d a CH HTML Cj boot bt 3 18 11 06 49 16 PM e CH Network C Lencore Release bin 3 18 11 06 49 10 PM amp a CH ROMDISK C Lencore Release cdm 3 18 11 06 49 12 PM eo Simpl C Lencore Release dip 3 18 11 06 49 10 PM Cj Lencore Release dsc 3 18 11 06 49 14 PM C Lencore Release rte 380 3 18 11 06 49 10 PM 3 Appio E Lencore Release sig 3 31 11 05 50 58 PM d 5 83 Sys Cj Lencore Master Module CCI vi 00 00 dll 3 18 11 06 49 12 PM em NVRAM Disk C Lencore Slave Volume Module CCI v1 00 00 dll 3 18 11 06 49 12 PM C SplusLibrary dll 3 18 11 06 49 14 PM C SplusManagerApp exe 3 18 11 06 49 14 PM C splusmanagerapp exe config 2 10 11 04 02 52 AM C SplusObjects dll 3 18 11 06 49 16 PM Se el Zl Connected tep 192 168 187 30 Z Crestron s Toolbox programming showing signal
13. ocated The signal file ends with sig In order to use the application you must get the signal file on the iPad prior to connecting it with the controller There are actually four ways to get a signal file on to your iPad 1 Email to one of your iPad managed email accounts Using the iPad email client it will allow you to open CrestDiag by pressing the email attached file Once the application is open you will notice the signal file has been automatically selected 2 When using iTunes you can select the app menu from your iPad device sync settings You will notice CrestDiag in the File Sharing section Dragging files into the CrestDiag Documents window will upload the signal files into the application Once the file is in your CrestDiag document folder you can select the signal file from the signal file selection section on the connection page 3 Using Cloud Services like Dropbox Dropbox is a free service when using less than 2GB of storage Dropbox has a free iphone ipad app that will prompt you to open CrestDiag when you select a stored signal file from its list 4 Using Crestron s toolbox program you can copy the signal file into the SIMPL directory on the controller CrestDiag can upload the file automatically when you turn on the upload feature from the connection page In the future Crestron s SIMPL Windows programming tool will allow the signal file to be downloaded automatically when you download your program Since the
14. tice four tabs on the left and the large detail view on the right The first three tabs hold the signals that were found in the signal file The fourth tab the Watched list is the list of signals that will be debugged with this program By default no signals are in the watched list you must select the signals to debug from the String Digital and Analog signal list Only the signals that have been assigned to the watch list will be debugged Pressing the Signals in the list will highlight the sunglasses associated with that Signal indicating that the Signal is now in the Watch list Pressing the signal again will remove it from the Watched list iPad 2 12 PM String Signals Disconnect Q Signal Control tt B t o i Bl d Lt a B TEE Ed CAMERA TYPE TEXT by Control Concepts Inc Select signal from watched list to stimulate IR OUTPUT TEXT Notification History a OFF Enable Notifications 7 Clear History Refresh SERIAL NUMBER TEXT SOFTWARE DATE TEXT SOFTWARE ID TEXT SOFTWARE VERSION TEXT TANDBERG CAMERA RXS TANDBERG CAMERA TX ARC String Signals In order to debug the program you must Enable notification on the detail view section You can add delete signals from the Watched list at any time iPad gt 2 13 PM Watched Signals Ka Disconnect Signal Control Signal Name pE P UU PAN LEFT a E
15. tions On o Cellular Data Ka Brightness amp Wallpaper E Picture Frame ap General Mail Contacts Calendars gs Safari ka Store Developer HM T CrestDiag Mobile Pro G 12 03 PM Notification Event History String Display Mode Analog Display Mode Max History Items Signal Managment Load SIMPL Module Signals On Disconnect Auto Clear Notify Event History When Applications Closes Remember Last Connecton CrestDiag ASCIMNHex gt Decimal 100 gt OFF OFF 76 Stimulating Signals Digital Signals iPad gt 2 13 PM Watched Signals E Disconnect isconnect Q Signal Control p Signal Name YT BW P LIL PAN LEFT Set High Set Low m UU PAN LEFT oo dum S Current State RJ High pulse Low l push UU PAN RIGHT Notification History LZ TANDBERG CAMERA RX on Enable Notifications i Clear History Refresh 38 TANDBERG CAMERA TX A TANDBERG CAMERA TXS Time 03 682 String PAN LEFT uu Time 10 588 Value 0 ITI PAN RIGHT Time 10 869 Value 0 PAN LEFT uL Time 28 008 Value 1 Mt TANDBERG CAMERA TX Time 28 035 String x81 x01 x06 x0 1 x06 x02 x0 1 x03 ff PAN LEFT uu Time 28 797 Value 0 a TANDBERG CAMERA TX Time 28 801 String x81 x01 x06 x0 1 x03 x03 K03 x03 xft AB TANDBERG CAMERA TX Time 29 854 String x81 x09 x04H xff Ma TANDBERG CAMERA TX Time 30 029 String x81 x09 x04G xfi T AB TANDBERG CAMERA TX m Time 30

Download Pdf Manuals