1. of one system B3 1 The number of receivers connected to the controller 6 The location of the transmitter 2 The area monitored 7 Gas detected 3 The communication failure icon 8 A graphic representation of concentration 4 The flooding icon 9 The concentration detected 5 The current temperature icon 10 The current status in the case of the connection of the DEGA Tc II sensor The individual transmitters are represented by white rectangles From the top position downwards the position of the transmitter in the diagram the gas detected the graphic indicator of its concentration the value of the concentration and at the bottom the status of the transmitter are displayed Transmitter can be in one of these states Ready the transmitter is functioning and is not detecting any dangerous gas ALARM 1 the transmitter is detecting a concentration higher than level 1 ALARM 2 the transmitter is detecting a concentration higher than level 2 ALARM 3 the transmitter is detecting a concentration higher than level 3 ALARM 4 the transmitter is detecting a concentration higher than level 4 ERROR a failure of the transmitters or of the controller In the upper right hand corner there is a space for the icons that show the status of the controllers If any of the controllers provide information concerning the ambient temperature the highest of these temperatures will be displayed Further to the left there is a spa
2. INSTRUCTION PA DEGA MANUAL h e Visualisation software DEGA VISIO IlI ISO 9001 2008 Quality Management Systems Syst me de Qualit www sgs com Content Page 2 Technical requirements Page 2 User guide Gi Reproduction of this manual or any part thereof in any form without the prior written permission of DEGA CZ s r o is prohibited DEGA CZ s r o reserves the right to alter the specifications of the hardware and software described in this manual at any time and without prior notice DEGA CZ s r o bears no liable for any damage resulting from the use of this device v FOR YOUR PROTECTION Utilise only certified DEGA accessories i The software is certified and is technically and functionally suitable for authentic DEGA accessories In the event that the software is utilised with other products the manufacturer shall not liable for any damages that this may cause v TECHNICAL REQUIREMENTS Operating System Microsoft Windows XP or higher recommended Windows 7 Other required software Microsoft Framework 4 0 Processor Minimum 2 5 GHz recommended dual core 2 5GHz RAM At least 2GB recommended 4 GB Free space on HDD 20 GB Ethernet for communication with controllers via Ethernet USB for communication with controllers via RS485 v USER GUIDE The Dega Visio IIl software is designed to monitor the status of controllers and the values of the transmitters installed in them Monitored events are store
3. ce for displaying the status or the error icons of the controllers which could indicate a failure of the thermometer a failure of the flood sensor the activation of the flood sensor or a communication failure If the communications error icon is displayed this means that the detection system is functional but that the visualisation computer is not connected to a specific controller Clicking on the system displays a window containing detailed information about the specific controller al Ad The figure in the example is showing that the detection system is composed of two UPAII controllers each of which has four transmitters The status and values of the transmitters are displayed together with the alarm levels for which they are set HISTORY window In this mode it is possible to browse through the event history of the individual controllers In the left column using the checkboxes it is possible to select which specific controllers and transmitters should be displayed Additionally it is possible to choose the time period for which the observation of a specific transmitter controller is required By using the display button a graph is presented showing a record of the measurements stored to the disk during a pre set time interval and utilised for the accurate determination of the observed events The view of the event log can be switched to a table view by using the Table button or to an alarm view by using the Alarms butto
4. d on disk at preset time intervals for later review and display Launching the application The application is launched by using a DEGA VISIO III shortcut or in the Windows Start Menu where it is located in the DegaVisio group Degavisio IT The DEGA VISIO III user interface After starting the programme DEGA VISIO can open in this interface for example Individual objects represent the systems that consist of controllers the transmitters of which are displayed in the systems The number and the distribution of the systems and their controllers are dependent on the configuration of the programme Several buttons are located at the top of the programme the speaker icon button is used to turn off the audio signal that is triggered in the event of an alarm or of a controller error the full screen mode button the use of which stretches the window across the entire desktop the history button for switching to the interface for viewing stored events and the values of the transmitters the settings button is used to access the configuration of the programme Through its activities the programme communicates with the installed controllers which transmit the status and values of their linked transmitters The individual systems display as many as the first 4 transmitters In the event of an alarm displayed in the first position are the transmitters that are in an alarm or an error status The diagram shows a detailed definition
5. n fff To be easily distinguished the individual sensors are shown in different colours By setting the appropriate time intervals we can observe the behaviour of the detection system over time The recorded values can be saved in the csv format e g for import to Excel or as TXT files using the Export button Manufacturer DEGA CZ s r o K i kovu 640 9 190 00 Prague 9 Czech Republic Tax ID CZ 279 029 43 Company ID 279 02 943 Telephone cz 420 774 447 660 5 Fax 420 227 203 512 E mail info dega cz Web www dega cz 2012 DEGA CZ S R O USER MANUAL VER OS5DEGAVISIOII201210 SEGA rons CE CL