Home
User Manual 3.vsd - Swift Owners Club
Contents
1. SAR ENT mobile alarm system Introducing the new Sargent STINGER 3I0 series modular alarm system Based on new technology and a two year design process the Stinger 310 incorporates ideas and feedback from users and experts throughout the caravan and security industries Designed to be modular the system can be expanded by a forthcoming range of wired and wireless accessories To ensure your STINGER 310 system is operated correctly please read all sections of these instructions before attempting to use the alarm If you are unsure of any content please contact your supplier in the first instance or the manufacturer direct Operation us Each STINGER 3IO is supplied with two key fob style radio controllers which are used to operate the alarm system Each key fob has four buttons which can be used as follows LED Torch button Press and hold the button to use the torch for night time convenience Arm Disarm button Press and release the button to arm the alarm one beep Press and release the button to disarm the alarm two short beeps To arm the alarm without the PIR movement sensor if you leave pets inside etc Press and hold the arm button and release after you hear one beep followed by two beeps Awning Light button Press and release the button to turn the awning light on or off note awning light control is an optional feature not present in all caravan models Programming Mode button Press and hold the butto
2. al office hours Further technical information is available at www sargentltd co uk For future reference it may be useful to note your alarm system serial number below which can be found on the sticker attached to the alarm system base unit Serial number arrasa Stinger 310 Manual Issue 1 June 2009 Page 3 of 4 i D a NEE NEEN NG Ga q
3. n for 10 seconds to access the 3 programming modes which are indicated by series of long beeps as follows One long beep Tilt sensor sensitivity adjustment Press the arm disarm button to select the required setting 1 beep low sensitivity for windy conditions 2 beeps standard sensitivity default 3 beeps High sensitivity Press the program mode button to move to the next setting Two long beeps Beeper volume Press the arm disarm button to cycle through the 7 available volume levels When you are happy with the selected volume press the program mode button to move to the next setting Three long beeps PIR movement detector sensitivity Press the arm disarm button to select the required setting pulse count 1 beep high sensitivity 2 beeps standard sensitivity default 3 beeps Low sensitivity for hostile environments Press the program mode button again to exit programming mode which is indicated by one extra long beep Stinger 310 Manual Issue 1 June 2009 Page 1 of 4 The STINGER 3I0 comes complete with a 120 Passive Infra Red PIR internal movement sensor that detects body movement within the vehicle If you are leaving pets within the vehicle the system should be armed without the PIR sensor active see key fob arm disarm section to prevent your pet from triggering the alarm Please be aware that direct sunlight onto the PIR lens or extremes of temperature above 30 deg C may affect the operati
4. ny point by pressing the key fob arm disarm button When the alarm is disarmed the Beeper will sound two beeps to confirm the disarm If the alarm has been triggered during the armed period the beeper will sound three beeps if the PIR triggered the alarm or four beeps if the Tilt Sensor caused the alarm If you hear multiple pips short beeps when you disarm the alarm this indicated that the internal backup battery is low and therefore should be charged The beeper volume can be adjusted using the key fob programming feature described earlier System base unit PIR movement sensor e Supply voltage 6 to 15v DC e Range 120 deg x 6M e Supply current 500mA max 5mA typical e Operating temperature 5 to 30 deg Celsius Key fob controller e Battery capacity 9Ah at 4 8v e Range 6M typical e Siren output 110dB 10 1M e Battery 2x CR2032 lithium button cell e Comprehensive interface connector details e Typical battery life 1 year on request The Stinger 310 system is supplied with two key fob controllers as standard but can accommodate up to four controllers per system Extra fob can be purchased from your supplier of direct from the manufacturer and can be added to the system by following a simple procedure For accessories interface harnesses installation documentation spare parts local supplier contact details or other service information please contact Sargent Electrical Services Ltd service desk on 01482 678981 during norm
5. on of the detector Always ensure roof light blinds are closed if sunlight could shine directly onto the PIR The STINGER 3I0 incorporates a new electronic tilt and motion sensor with automatic calibration and easy sensitivity adjustment from the key fob This feature provides excellent tilt detection with no moving parts The tilt sensor works automatically and does not need adjustment for normal use even if you park on a steep incline The sensitivity of the sensor can be adjusted as described in the key fob programming section When the STINGER 310 alarm system is armed or disarmed the Awning light will be activated for a period one minute to provide illumination whilst entering or exiting the caravan The Awning light can be turned off during this period by pressing the Awning light button on the key fob if required note awning light control is an optional feature not present in all caravan models The Awning light can be turned on or off at any time by pressing and releasing the Awning light button The STINGER 3IO system unit uses a special 4 8 volt Nickel Metal Hydride battery pack that supplies backup battery power to the system should the supply from the leisure battery fail or be disconnected It is recommended that the alarm system is permanently connected to a 12 volt supply When fully charged the battery will provide approximately 6 months stand alone operation depending on
6. temperature conditions It is recommended that this battery pack is replaced every 3 years Before placing your caravan in storage please ensure the caravan has had a fully charged leisure battery fitted or the mains charger switched on for at least 14 days prior to storage to ensure the the internal backup battery is fully charged It is recommended that a leisure battery remains connected to the caravan during storage Always dispose of old batteries in accordance with local regulations The STINGER 310 key fob controllers use two lithium button cells CR 2032 in each key fob Please note that excessive use of the LED torch will reduce the life of the batteries considerably To replace the batteries firstly remove the four cross head screws from the underside of the fob then pull apart the two halves of the fob Remove the used batteries from the lower half of the case then insert the new batteries in the same manner noting that the battery positive faces away from the green circuit board Now reassemble the fob casing and refit the screws taking care not to over tighten Stinger 310 Manual Issue 1 June 2009 Page 2 of 4 The STINGER 3I0 contains a dual sounder unit that provides the loud alarm siren and the volume adjustable beeper sound When the alarm is triggered the siren will sound for 2 minutes Following the 2 minute period the alarm will then deactivate for 15 seconds and then rearm The alarm siren can be turned off at a
Download Pdf Manuals
Related Search
Related Contents
User Manual_SNP-3371-ITALIAN_Web.indb BBA 2864 / 2866 【PDF】漏液センサ RS1000*A 取扱説明書|東横化学株式会社 Gamber-Johnson 7160-0504 mounting kit Page 1 Page 2 Page 3 JJ J JJ J J J JJ J J JJJJJ JJ ゴ 〉 ー次 1 De - Aerne Menu SPT5-H -german T R A V EL A N G EL – S E R IES T R IP O D S Renaissance Group RC-30A12-240 User's Manual Copyright © All rights reserved.
Failed to retrieve file