        Annexure-1 Specifications for Sl. No:1 - NPCIL e
         Contents
1.             
2. Annexure 1    Specifications for Sl  No 1 Contamination Monitor                                                       SI No   Parameter Description Supplier   s remark on  compliance deviation  1    Item Contamination Monitor  portable    Purpose To assess beta  beta gamma and alpha surface  contamination on floor  equipments  surfaces and skin in  nuclear power plant    3    Detector Geiger Muller Pancake  Protective grid shall be at least  80  transparent   4    Contamination   Counts from 0 to 10 000CPS or more   measurement Surface activity measurement from 0 to 5000Bq cm  or   range more  Fixed contamination  Dose rate  from 0 10 uSv h to 5000  uSv h or more   5    Display Display shall be LCD display having provision for display  of alarm and status report   Display unit shall be in cps  Bq  uSv h and Bq cm     For the  Bq and Bq cm  mode  user shall be able to select different  nuclides from built in library  The following radionuclides  must be there in the built in library  Cs 137  Am 241  I   131  Sr 90  Co 60   6    Measurement Automatic adjustment from 1 to 60 seconds  Adjustable in  intervals count up mode by buttons  7    Alarm Visual and acoustic  Provision to set at least one alarm  threshold  8    Case Suitable protective case shall be given for storage  9    Battery Readily available batteries like AA type  10    Operational From 15   C to 40   C  temperature  range   11   Approximate Around 400g or less  Weight  12    Approximate Dimensions should be approx
3. from 15  C to 40   C  temperature or better   10    Approximate Weight shall not be more than approximately 250 g    Weight including batteries   11    Approximate The medium range gamma radiation survey meter shall be a  Dimensions small hand held  battery operated survey instrument   Dimensions shall be approximately within 85mm x 40mm x  140mm so that it can comfortably fit inside coverall pocket   12    Manual User manual and maintenance manual shall be provided  13    Warranty Warranty period and its coverage shall be minimum 1 year  after commissioning at KGS and be clearly mentioned  14    Additional Energy response curve shall be supplied  requirements Calibration certificate shall be supplied          EMI standards in accordance with IEC norm 61000 3          Specifications for Sl  No 3 Low Range Survey Meter                                        SINo   Parameter Description Supplier   s remark on  compliance deviation  1    Item Low Range Gamma Radiation Survey Meter  Purpose To assess low level gamma radiation field inside nuclear  power plant  3    Detector Detector shall be energy compensated GM tube or  Nal Tl   gamma energy response according to H  10   4    Dose rate 0 01 uSv h to 0 01 Sv h or more  measurement  range  5    Energy response It shall measure gamma and X rays from 50keV to  3MeV  6    Measurement Three significant digits or 0 01 uSv h on dose rate  resolution  7    Configurable uSv h  mSv h  Sv h  units  8    Display Unit Display shall be illumi
4. imately within 85mm x   Dimensions 25mm x 140mm so that it can comfortably fit inside  coverall pocket  The contamination monitor shall be handy  and should not have external cables   13   Manual User manual and maintenance manual  soft as well as hard  copy  shall be provided  14    Warranty Warranty period and its coverage shall be minimum 1 year  after commissioning at KGS and be clearly mentioned  15   Additional Energy response curve shall be supplied  requirements Calibration certificate shall be supplied          EMI standards in accordance with IEC norm 61000 3             Specifications for SI  No 2 Medium Range Survey Meters          SI No       Parameter       Description       Supplier   s remark on             compliance deviation                                                 1    Item Medium Range Gamma Survey Meters  2 Purpose Medium range survey meters are used for surveying  moderate gamma radiation field during normal operation  and during shutdown  3    Detector Energy compensated GM tube  Gamma energy response  according to H  10   4    Range It shall be able to measure dose rate of 10uSv h  or less  to  100mSv h  or more   Display range shall be from 1 uSv h  to 100mS w h  5    Energy range   For measuring gamma and X rays from 50keV to 3MeV  6    Alarm It shall have provision for acoustical and visual alarm  7    Display Unit Display shall be illuminated LCD display  8    Energy supply   AA type  9    Operational Operational temperature range shall be 
5. n  compliance deviation  1    Item Alpha beta Counter  Purpose For assessing loose contamination of personnel   instruments  floor  personnel protective items etc  in  addition to assessing system activities   3    Radiation Detected   Alpha and Beta Particles  4    Detector ZnS Ag  adhered to Plastic Scintillator mounted on  PMT  5    Efficiency  2pi   Greater than or equal to 50  for Pu     60  for  Geometry  Th      40  for Sr     Yr     10  for C 4  6    Background Less than 3cpm for Alpha particles  less than 80cpm  for beta  7    Crosstalk Alpha to Beta  lt 10   Beta to Alpha  lt 1   8    Electronics All solid state  Micro Controller based design  9    Operating Mode Preset Timer  9999 Secs  10    Sample holder Sample holder shall accommodate 3 5cm_ diameter                planchette                               11    Menu Display Counts   999999 or more  Time   9999 sec or more   12    HV Supply Adjustable by setting the heliport with graduated  dial   13    Data storage Store and recall facility for data more than 500  readings  Compatible PC shall be supplied if data  storage is via PC   14    Data transfer For PC  USB 2 0   15    Power 240V  50 Hz AC mains supply   16    Manual User manual and maintenance manual  soft as well as  hard copy  shall be provided   17    Warranty Warranty period and its coverage shall be minimum 1  year after commissioning at KGS and be clearly  mentioned   18    Additional Calibration certificate shall be provided       requirement    
6. nated LCD display  9    Alarm Configurable audible and visual alarm  10    Communication RF communication or USB communication with          suitable adapter                                              11    Power supply AA type  12    Approximate Approximately less than 250 g with batteries  Weight  13    Approximate 15  C to 40  C or better  Operating  temperature  14    Case Suitable protective case shall be given for storage  The  monitor shall be water proof including battery  compartment so that the monitor can be used for  environmental survey in rainy season  15    Accessories Accessories like pouch  pocket belt clip shall be  provided  16    Approximate The low range gamma radiation survey meter shall be a  Dimensions small hand held  battery operated survey instrument   Dimensions should be approximately within 85mm x  40mm x 140mm so that it can comfortably fit inside  coverall pocket  The monitor shall have ergonomic  design  17    Manual User manual and maintenance manual  soft as well as  hard copy  shall be provided  18    Warranty Warranty period and its coverage shall be minimum 1  year after commissioning at KGS and be clearly  mentioned  19    Additional Energy response curve shall be supplied  requirements Calibration certificate shall be supplied  EMI standards in accordance with IEC norm 61000 3                Specifications for Sl  No 4 Alpha Beta Counter                                                 SINo   Parameter Description Supplier   s remark o
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Programmation du Golo Mode d`emploi de la version Golo    eds·3g servicio sentilo manual de configuración  DGM1D - CDVI  Avaya MultiSite Administration Release 2.0 Configuration Configuration manual  株 主 各 位 定時株主総会招集通知書 記  Mini Lathe  Atlona AT-HD570 video splitter  StarTech.com 2m DVI to VGA Display Monitor Cable M/M - DVI to VGA (15 Pin)  取扱説明書    Copyright © All rights reserved. 