1. 1 New It is used for creating a new project please refer to chapter 2 1 for step introductions Also you can click new icon 11 to finish the same operation 2 Open It is used for opening a saved project which type is twp Also you can click lL After clicking a pop up dialog box will appear Choose the project you want to open and then double click 1ts icon or just click the icon and then click Open 39 Software Parts 40 Look irr New Folder Twin v2 75070928 E offline offline online File name offline online Files of type Project File twp Lancel 3 Close It is used for closing Touch Win edit tool software If you have not saved the updated project when you choose Close the following window will pop out File Save Project hasn t saved yet Saver If you want to save this project please click Yes if not please click No Then you ll quit this project 4 Save If the project you want to save is a new one Save dialog box will pop out please type your project name then click Save to confirm After this operation it will save the new project instead of the old project automatically has the same function When editing the active present project please click save continuously to avoid losing you project It s dialog box 1s shown below Software Parts d My Computer Ly Network Places liad New Folder
2. MM Screent T m x x aw 93 Software Parts 94 If there are three objects set the biggest rectangle with Bottom Layer the smallest one Top Layer and the third one with default setting then superpose them together Finally you can see the following effect MM Screen Ea If you want to change this setting right click the selected object to open 1ts pop up menu and choose relevant options While please note that there are Bottom Layer and Top Layer withhout Middle Layer Software Parts 4 15 Adjusting Graphics This function 1s used for aligning and adjusting the maps or components in horizontal or vertical direction 1 Firstly Place some components and maps on the project screen as shown below 2 Select all of these objects to spring the Align buttons try to use each of them and you can see the following effect Align Left lee Align Center EH On o 66 ihe 22 s 66 a Align Right 91 7 Align Top t 95 Software Parts Align Middle l a 96 ey Align Bottom 22 Software Parts 5 BASIC COMPONENTS This chapter introduces how to use components in Part toolbar which are used mostly As shown below there are Text Dynamic Text Variational Text Lamp Button Lamp Button Screen Jump Digital Display Alarm Display Text Display Digit
3. Object Data in Object property page Station stands for the device communicating with display The setting values are different as station numbers are not the same when using different devices Normally we use default value need not to change by user Object Setting a number for the register which can be set as internal space of touch screen or communicating device Take DO for example internal data register of Thinget XC series the display can monitor the changing value of DO directly Data Namely data type normally we select Word stands for separate word Dynamic Text Object Display Font Color Position Station Device PLi_ Port T WirStahlo Station 1 Object Obiect D O Indirect Word 4 Each register corresponds to 16 status each part s corresponding value is 0 15 when the register s value is 0 the dynamic text will display the content of text 0 The rest may be deduced by analogy You can also select align type and text frame as shown below 102 Software Parts Dynamic Text Object Display Font Color Position Align Wer C Left C Top Center Middle Changing C Right C Bottorn ETE 5 Font Color and Position option are as same as Text components please refer to above chapters 103 Software Parts 5 3 Variational Text In the industry control process there are several status of machine By these dynamic texts t
4. Panel Device Screen Start Screen Ho Passowrd Level Password E Screen Save Latency Time After 3 Minute f Close LCD C Show Screen As shown above parameter set is divided into three items Screen Password and Screen Save 7 Screen It is used for setting the start screen namely the first screen after TP electrified Generally we set this screen as the main menu or the most used screen it is set by screen No m Password gt To improve the safety of machines the data in TP series touch screen can only be modified by special personnel Therefore TP touch screen can help user protect data more efficiently gt Password has three grades common advance and system Common password can only carry out functions with itself advance password can carry out function with advance and common and system password can carry out all the password operation gt There passwords usually for hiding or encrypting the parts or screens Only type right password you can open or do the relevant operation gt The password input box showing above is for common one if you want to enter advance and Advance system grades please slick Seno and type password as shown below Software Parts Password Advance System Screen Save This function operate automatically when touch screen has not been sprung for a long time When it arrives the setting time touch s
5. Software Parts Project Set Color Font Froject Fara Alternation Clock Panel Device Model TPA460 T Deserption 800600 256 colors Set parameter E This function mainly describes the touch screen and how to set internal storage space As shown above the current touch screen is TP A60 T if you want to change its internal storage space setting please click Set parameter to open the following window About touch screen internal space please refer to chapter 10 to get particular introductions 46 Software Parts Device Project 5et Color Font Project Para Albernation Clock Panel Device PLC Port Model Thinget AC Seres Param 19200 6 Even 1 Station HO Download Port Mode Thinget AL Seres Param 19200 Even 1 Station HO As shown above this function is to setting PLC port and Download port When you want to change device or communication parameters while editing modify the relevant options in Device 47 Software Parts Project 5et Para Altermatiorn Clock Panel Device Color Font Project Eind Color A eee EE An E More ES Color 1s used for setting background color there are 256 kinds of color can be choose in this software Please pay attention that once the color is set it will effect all the project screens as shown below I TouchWin Edit Tool Project Screen EE mmm rE AA ACA IN SOCOCCOHER
6. Window menu is used for dealing with screen It contains New Cascade Tile and Arrange Icon TouchWin Edit Tool Project Screent File Edit View Park Tool Wym mi O a EH New Cascade Tile Arrange Icon na H A e em a ttle Cc Po lor s an sin Gn Xx Xx Project AA Copy the current screen to create a new screen m New 7 Cascade Arrange all the open screens with cascade pattern m Tile Arrange all the open screens with file pattern Arrange icon Arrange the icons 3 7 Help About Y There are imprint and copyright instruction of TP touchwin edit tool AboutTouchWin Edit Tool Touchin Edit Too We Tb Copyright C 2004 Touchin Company CANADA 6l Software Parts 3 8 Other Operations m Graphics Adjustment Align oe HH Sa SF 080 0000 As shown above the Align toolbar is used when several objects need to be arranged Align Left Align Center Align RightWAlign Top Align Middle Align Bottom m Zoom 0 0 Zoom toolbar is used for making the whole screen or window display more clear to convenient some particular operations The icons from left to right are zoom in current scaling can be chose from the pull down menu zoom out grid m Status Status X 62 Software Parts 4 MAKING GRAPHICS This chapter introduces how to edit graphics with draw toolbar NOCOcCeORm k 1 S
7. refer to up chapter for relevant introduction 168 Software Parts April 5 Please refer to previous chapters for relevant introduction about Color and Position 169 Software Parts 6 S Pump 22 1 Click R and press left mouse button to add a pump to the screen as shown below MM Screen1 2 Double click the pump on the screen 1ts property dialog box will pop out containing Object Aspect Speed Color Position In Object tab page control address of the pump can be set as shown below Object Aspect Speed Color Position Station Device ienae WIrstaWo Station 1 Object Obiect m O Indirect 170 Software Parts 3 From Aspect tab page the aspect and direction of the pipe can be set as shown below User Defined Save Aspect Direct C Order f Reverse Ok Cancel Fump_T A 001 Fump_T A 002 Fump TA 003 Fump_T_A 004 Pump_T_A 005 4 Please refer to previous chapter for relevant setting instruction about Speed Color Position 171 Software Parts 6 9 Auto Wind cy 1 Click and press left mouse button to add Auto Wind to the screen as shown below MM Screen E Ed Ps 2 Double click Auto Wind and open its property dialog box Setting as pipe Auto Wind Object Aspect Speed Color Position Station Device WIrstaWo
8. 2 Open its property dialog box and type number in Screen ID box Screen Jump Jump Button Color Position Screen ID i 3 Next we choose Button tab page and modify its aspect and use display 114 Jump Button Color Position Password Hide Button Normal Change Aspect v Use Text User Defined Content Press Save Aspect Font Align Lett C Align Top f Align Center f Align Middle C Align Bight C Align Bottom cancel toy 4 Please refer to chapters before to get particular introduction of Color and Position Software Parts 115 Software Parts 5 8 Digital Display In the industrial control process the working parameter of the machine could tell whether it is ok or not So it is display s another advantage to display the machine s action in figure This function is the contribution of Digital Display 1 Click Digital Display part gt 2 Move the cursor to the screen and click left mouse button to finish placing the digital display part right click or press ESC to cancel placing Screen KE 3 Open its property dialog box as shown below the property page of object is used for pointing address that you want to display Display Digital Object Display Font Color Position Station Device a VWirStahlO Station 1 Object Obiect E O Indirect Data Data Word Cancel 116 4 Display
9. 5 Turn on the X0 of PLC namely set 1 for X0 and then observe what will change in the simulating screen as shown below 205 Software Parts 6 Now the PLC succeeds to simulate the control process without connecting touch screen 206 Software Parts 9 3 Configuration This function is similar with Simulate Online The only difference is that Configuration can do the simulating function separately without opening graphics edit software 1 Firstly edit a project screen and save it 2 From File menu select Build SCADA 3 Then a window will pop out which 1s used for saving configuration files as shown below Browse for Folder El E CENI NTA 14 p14D 0 Desktop En G My Documents F My Computer Sat Local Disk 0 4 Sg Local Disk De Local Disk E Local Disk F hy DWD Drive G Shared Documents y cindy s Documents eGo HOJ A a My Network Places aA Meim Falder 4 Select address to save files then click OK to finish it 5 In the address of saving you may find there have been add some files MES oo Operate log D FEY dat O Runata xm Yar DAT wt im tHE 1 EE 16 364 EE ol EB AutoWin exe HmiEmluator Micr a softfare ini MARHA 1 EE 6 When you need to simulate operations please click AutoWin exe to enter its state as shown below 207 Software Parts 7 Please refer to Simulate Online f
10. Change Map 131 Software Parts 5 19 Call Window Call Window 1s used for opening the needed window by controlling coils open or close The following describes how to use it 1 Create a new window to be transferred Set the window s size name and other information Window ID il Width i 60 Name window Height 1 O Message Cancel 3 Click the property button Set the relay s type and address in object tab page and set the window No called in Window tab page When the middle relay is in the state of ON the window to be called will popout When it is OFF the window will be close As shown in the following maps 132 Software Parts Call Window Ubject Window Position Station Device jakaisi WIrstaWo T Station 1 AE Set address Object Obiect fm Bi o Indirect Call Window Object Window Position Window Set Window No Window ID 133 Software Parts 5 20 Window Button We have introduced calling the window before But in the process of invoking the window you may discover that you need a relay and that make operation so trivial also when we open the window we couldn t close it in the current window Window button can solve all of these problems The following introduces how to use the Window Button 1 Create a new screen click El in Part Toolbar and place 1t on the screen MM Screen 2 Open the proper
11. D stands for decimal data 225 TP FC CABO Wiring Diagram TP series touch screen side 9P D SUB Female FC XC series PLC side P D SUB male P Mini DIN Male Portl Port2 Appendix 226 Appendix 1 2 Mitsubishi FX Series TP software setting Parameters Recommend Mitsubishi FX PLC model series Data bits 7 Stop bits l Parity Check Even Baud rate 9600 Station No 0 Device Address PLC Address Range Format Introduction Type XO 0 267 Exterior input terminals YO 0 177 Exterior output terminals MO 0 1023 Internal assistant terminals S 0 999 Special assistant terminals T Cas status 0 255 Timer status C 0 255 Counter terminals C16 O O O O O O 0 199 O 16 bits counter C32 200 255 32 bits counter D 0 8255 D Data memorizer T Cas register 0 255 Current Value OX Y M Scan be extend as registers 221 TP FX CABO Wiring Diagram 1 CPU Unit TP series touch screen side 9P D SUB Female l O 5 GND 2 Communication Modules RS232BD TP series touch screen side 9P D SUB Female FX series CPU RS422 port 8P Mini Din Female FX series PLC side P D SUB Female 3 Communication Module RS485BD 228 TP series touch screen side 9P D SUB Male FX series RS485BD module RS485 port 5 wiring terminals Appendix 1 3 Siemens
12. EJE a Screen _ MENA a a a aa a la La USNA E A E Screent ie o o o pitied Li O A AE i om do B Insert a window in the project manager The detail operations are as the following Click the window in the project manager with your left key to make 1t turn to hightlight color Then right click it and choose Insert in the pop up menu x Project Screen Screen Window a Alarm z pa Alarm Window nia gt Print 2 There will come out a new alarm window dialog box Set the window s name width height register and pop period and then click OK to confirm 197 Software Parts Warn Window Indo Alarm Window Message Signal address which can spring alarm Register geien No repeat pop means when the alarm window pop Object one time it will not alarm again S sec means after Period Alarm window pop out and Bis cele No repeat pr press OK to cancel the alarm window will appear o Cancel every five seconds 10sec 30sec Imin Smin 3 The finished alarm window is showing in the following figure 10min 30min are the same as 5 sec ES Alarm Window 4 Double click Alarm and Alarm Define and then a Text dialog box will open in which information and details can be modified as shown below 5 When alarm happens a window will pop out automatically The operator can take eff
13. File name Project save as type TouchiwinProject File twp r Cancel 5 Save as It 1s different from Save Save means save active project with 1ts current project name while Save as means save the modified project with a new name and do not rebuild the old project After choosing this option save dialog box will appear then type your project name and click save to quit 6 Download It is used for downloading data in Touch Win edit tool software to TP touch screen Click Gal can finish the same operation To get more particular information please refer to chapter2 2 2 7 Simulate on line It is used for realizing simulation on line Choose this option you can simulate TP action in TocuchWin E Edit Tool after connecting PLC and computer Click the icon can finish the same operation 8 Simulate off line It is used for realizing simulation off line Without connecting computer and PLC or downloading screen al R data to TP you can simulate TP action in the software Click the icon can finish the same operation 9 Setting For system 29 66 It is used for setting or modifying the main parameters and other items such as parameter alternation 29 66 clock panel device color font project The following will describe them one by one 41 Software Parts 42 Color Font Project Para Alteration Clock
14. Lamp Button and Screen Jump all of which are used for operating coil i Lamp a 53 Software Parts 54 Show the switch status in order to match the operation of button Refer to chapter 5 4 for particular usage m Button gt Open Close a certain operation to control the bit component Refer to chapter 5 5 for particular usage z Lamp Button O gt Carry out the operations of both lamp and button Refer to chapter 5 6 for particular usage z Screen Jump Ps Let the current screen jump to a certain screen Refer to chapter 5 7 for particular usage 3 Display It contains Digital Display Alarm Display and Text Display all of which are used for reading data or characters from registers 7 Digital Display EEE Read data from registers and support various digital format data length and font Refer to chapter 5 8 for particular usage z Alarm Display Read digital values from register and you can set max and min range If the data in the register over this range the reading out value will twinkle to alarm Refer to chapter 5 9 for particular usage Text Display E Read characters from registers and support multi words display without restriction of length Refer to chapter 5 10 for particular usage 4 Input It contains Digital Input Text Input and Set Data all of which are used for typing information into regi
15. Align Lett C Align Top Align Center f Align Middle Set button aspect After ticking Hide Button C Align Right C Align Bottom E the button will become transparency Lancel Click Change Aspect to open the following window 109 Software Parts Gallery Gallery ButtonT_Circle_0 Button _T_C_A 00 There are Gallery 1 and Gallery 2 Gallery 1 has 20 kinds of multicolor pattern Gallery 2 has 23 kinds of white and black pattern 6 Here we do not introduce the property pages of Color and Position you can refer to chapter before 110 Software Parts 5 6 Button Lamp The lamp button has a function of both lamp and button It can control as well as display and each function 1s relevant with a separated relays In TP software the default display and control are pointed to the same relay 1 Click Lamp Button O to place a lamp button on the screen MM Screen 2 Setting property of Lamp Button Button With Lamp Object General Aspect Color Position Operate Object Station Device isa Virstaho Ci Station 1 Object Obiect M O Indirect Status display and status M Watch Object control point to the same Station rela without tickin Device Pec Port y y 8 66 39 WirStaNo O Station 1 Watch Object Object Obiect ra gt O F indirect 3 General 111 Software Parts Button With Lamp Obje
16. Color Position Content Data StringDescript Add Off over add 4 Off over constant 4 E Off over Sub 4 OFF over dd Y OFF over constant W OFF over stop and throttle mare W Aspect Align Hor Align er C Left C Top Center Middle ChanginafU Eight Bottom Cancel Analy Description presentation gt 16 Over circuit is cut off when speeding up gt 17 Over circuit is cut off when speed is determined gt 18 Over circuit is cut off when speeding down 217 Software Parts gt 32 Regenerative over voltage is cut off when speeding up gt 33 Rebirth over voltage is cut off when speed is determined gt 34 Rebirth over voltage is cut off when speeding down or stop gt 48 Inverter over load open circuit gt 49 Electric machine over load open circuit gt 64 Radiator is over the temperature gt 96 Loss speed precaution gt 112 Control action transistor alarm gt 128 Output side connect to the ground over circuit protection gt 129 Output wrap the phase protect gt 144 Outside hot relay act gt 160 Choose unit abnormal gt 176 Parameter memory abnormal gt 177 Parameter unit drop off gt 178 Retry times exceeds gt 243 Choose unit abnormal gt 246 CPU error gt 247 CPU error gt 0 No alarm information 218 Software Parts 3 Place on the screen and open its property dialog box as shown below Button Object Oper
17. PLC Address Range Fromat Introduction Type Internal M 0 2047 DDDD terminals Register MW 0 2047 DDDD terminals TP NEZA CABO Wiring Diagram TP series touch screen side Schneider PLC side 9P D SUB Female SP D SUB Male 242 1 10 Fatek FB series PLC TP Software Setting Parameters Recommend PLC Fatek FB Model COM Type RS232 Data Bits 7 Stop Bits l Parit 7 Even Check Baud Rate 9600 Station No 1 Device Address PLC Address Range Format Introduction Type0 XO 0 255 DDD Exterior input terminals YO 0 255 DDD Extrior output terminals MQ 0 2001 DDD Internal input terminals S 0 999 DDD Sequence control terminals T As status 0 255 DDD Timer status 0 255 2 a Counter terminals 0 199 16 bits counter C32 200 255 DDD 32 bits counter 0 9000 DDDD Data Memory 0 3071 DDDD Data Memory As 0 255 DDD Timer a OX Y Mand S all could be expand as register Appendix 243 TP FB CABO Wiring Diagram MA series standard CPU unit offer one HEMOS COM port MC series offer three COM ports 1HCMOS amp 1RS232 amp 1RS485 MA series CPU unit can be connected after you let HCMOS transfer to RS232 RS485 visa communication module FB DTBR or FB DTBR E 1 RS232 Port TP series touch screen side MC series CPU RS232 port 9P D SUB Female communication module FB DTBR DTBR E 232 por
18. Position Button Prey Page Frey Page Next Page Prev ltem RezetConterit Event Button integrates several function buttons as shown below 187 Software Parts Prev Page Page up the data objects and displays them Next Page Page down the data objects and displays them Prev Item Point to previous item of the current data item Next Item Point to next item of the current data item OK Confirm all the data items and record the current time Reset Content Clear all the data in the data object The following 1s Button tab page please refer to previous chapters for relevant introduction Event Button Event Button Color Position Password C Advance System Hide Button a e User Defined Content Fress Save Aspect Font Align Lett Align Top f Align Center Align Middle Align Bight Align Bottom 4 Please refer to relevant chapters for introduction about Color and Position 188 Software Parts 6 16 Display Real Time Event Display Real Time Event 1s used for reflecting the currents event at real time and describing them with text In project application it is often used as information note alarm and so on 1 Click El and press left mouse button to add it as shown below DER Pr MM Screen 2 Double click it to open its property dialog box The first tab is Aspect with which name rows row parameters align mann
19. Ps 2 Double click it to open its property dialog box the first tab is Object which is used for assigning data address of alarm Variational Text Object Display Font Color Position Station Device WIrstaNo Station 1 Object Obiect E O Indirect Data Data Word 178 Software Parts 3 Display tab page is used for setting alarm contents correspond to values The display characters can be set by ticking aspect as shown below Variational Text Object Display Font Color Position Content Daa String D escript TextEx Delete Aspect Align Hor Align Ver Text C Lef C Top Center Middle Chanainall C Right C Bottom Cancel app 4 Please refer to previous chapters for relevant introduction about other tabs 179 Software Parts 6 13 Real Time Trend Real Time Trend is used for reacting the real time status of a certain simulate value There are various display manner for you to choose such as curve column map dot map and other manner Real Time Trend is often used for prompting temperature pressure liquid and so on Therefore it plays an important role in the projects 1 Click and press left mouse button on the screen to add it as shown below E Screen Enix Real time Trend Trend Map Color Position Add object one object correspond to one trend curve Modify objects property Ob
20. tab page is shown below Display Digital Object Display Font Color Position Format Bit Length C Dec H Total 5 0 Eloat Float 0 Ww Aspect Align Hor Align Wer B i 00000 Lei Lop Middle Changing Fgh C Bottom Cancel Software Parts Set format of the display digital Set bit length of the display digital Set align of the display digital Refer to Text for instruction about Aspect 5 Font Color and Position are similar with these in Text you can set them freely 117 Software Parts 5 9 Alarm Display In order to protect the operation some data must have certain restriction Data alarm display will glitter when the data exceed the restriction This will awoke the operator to take action E 1 Click Alarm Display icon in part toolbar 2 Move the cursor to the screen and click left mouse key to finish placing alarm display Right click or press ESC can cancel placing MM Screen 3 Click Property to open its dialog box Compared with Digital Display they have the same setting except that alarm display add a Range tab page In the following we mainly introduce Range tab page Without it Alarm Display has the same usage with Digital Display Display Alarm Set the max range of Object Display Range Font Color Position alarm it will twinkle to alarm when data exceed its ma
21. 4 16 TP760 T Dimension TP760 T Actual dimensions Unit mm 200 0 X 148 0 X 44 4 Cutout dimensions Unit mm 182 4 X 134 4 loz 4 TPA60 61 Dimension TPA60 A61 Actual dimensions Unit mm 311 X 234X48 Cutout dimensions Unit mm 301X224 301 0 4 al af e r e F 5 E F F F P a F Fa a Fa y A Fa F ni Fa F F a 22440 4 Hardware Parts 17 Hardware Parts 5 INSTALLATION METHOD When you buy a TP there will be 4 iron install racks with it There are two square fix holes on the display s upside and downside Use the mounting bracket to fasten the display tightly in the control tank s install holes For Touch screen s temperature will go high if it works too long be Sure to install the touch screen at least 10cm away from adjacent structures and other equipments each side 5cm to keep cross ventilation Installation Panel Mounting Bracket F gt L Step Refer to hereinbefore graph s size Open an square hole on the control tank s panel Step2 Add airproof circles in the airproof trough while installing Step3 Insert the TP into the cut out of the control tank Step4 Set the mounting bracket into the displays side fixing hole and tight the screw Step5 Connect the display and PLC communication ports with cables The communication cable can be offered by the supplier or made by user according to the connecting graphics give 24V DC power to start working 18
22. 40 Note This manual only introduce the elementary functions of the software Please refer to other manuals about the advanced functions 24 Software Parts 2 GETTING STARTED Before you editing TouchWin program make sure touch screen and PLC models which are the precondition to decide whether the software could download and communicate normally 2 1 Creating A New Project 1 Click New icon in the standard toolbar or click New under File menu as shown below I TouchWin Edit Tool SN Edit Part Tool VIE Standard Ed SEA Cerler Open Ciro TEE s 2 When you create a new project a pop up dialog box as shown below will appear Select touch screen model and then click Next Panel Select Panel TP6 Series Touch Panel EN TP460 L EN TPS60 L EN TPS60 G EN TPS60 1 2 T ETP Y60 T E TPAGO L 3 TPA50 T 3 TPAGT T 47 OPSO Series Operate Panel 47 PC HMI Software Atte 460234 256 colors q D Cancel a 25 Software Parts 3 In the following figure you can choose port PLC device with default settings of communication parameters If you want to modify these parameters click Setting to open its dialog box Please select port PLC device Thinget sC Senes Thinget FC Series Mitsubishi Fa Seres Omron CPMm COM Seres Omron CP1H Series Siemens 57 200 Seres Siemens 5 7 300400 Kopo 5 Seres Schneider MicroMeza T wido Matsush
23. AGE OR RISA e jer Ba so Fo Hjem BE h S oe a w d e Protect MM Screen izo MS Screen irei E Screen a de a 48 Software Parts Project 5et Para Alteration Clock Fanel Device Color Font Project Demo Font is used for setting words in the project screen click setting to open Font window as shown below Font style Microsoft Sans Serif Microsoft Sans Serif Ae C T MingLil Une Modern O Monotype Corsiva Bold Italic Tp M5 Gothic J Y MS Mincho Tp M PGothic v Effects E Sample Strikeout Underline alo Ee Color Black Script Western T You can set font font style size effects color sample script and so on These functions will be introduced particularly in the next chapter 49 50 Software Parts Project Set Alternation Clock Panel Device Font Project Remark As shown above you can add name author and remark in project set dialog box 10 Build SCADA When click Build SCADA there will create some files Also a pop up window will appear to prompt where to save these files After editing find this folder execute AutoWin exe can realize configuration function 11 Last File If you have open or edited some projects recently th
24. D is 0 Scale is divide into 4 sections each of which has 3 slave scales As shown below Vertical Bar Object stick Color Position Preview i Scale Upper Limit Lower Limit Man Scale Slave Scale Aspect Data O lara Format Dec C EBottom Left hr as Mode caca emp 129 Software Parts 5 18 Dynamic Map The setting of Dynamic Map is similar with Dynamic Text If the register s value is different they will all display different text or map The register value ranges from 0 to 15 16 states As the register value 0 15 is different it will display different maps 1 Click and place it on the screen MM Screen E E e 2 Property setting there are Object Map and Position tab pages Object 1s used for setting object that need to control Dynamic Map Object Map Position Station Device WirstaWo Station 1 Object Obiect D O Indirect Data Data Word Cancel Apply 130 3 From Map there are 16 maps choose the map No from the left box and click button to change map Dynamic Map Object Map Position Pictured Picture Pictures Pictures Picture Pictures Pictureb Picture Pictured Pictured Picture 0 Picture 1 Changing Oh red 7 Cancel Note The format of these maps should be bmp Software Parts Changing Le Map No Preview
25. Dd gt Show the changing value in the assigned register s via map it is similar with Dynamic Text There are 16 kinds of map in the software Also you can use your own maps Refer to chapter 5 19 for particular usage 8 Window It contains Call Window and Window Button which are used for switching screen and window a Call Window E Control the pop up window by a bit component of appointed coil of a register usually it 1s sprung under certain conditions Refer to chapter 5 20 for particular usage Window Button 66 CJ 22 o Without controlling coil only press this button can open or close the appointed window 9 Recipe It contains Down Recipe and Up Recipe which are used for realizing recipe functions 55 Software Parts e Download recipe data from touch screen to PLC Refer to chapter 5 22 for particular usage gt m Down Recipe Up Recipe Opposite from down recipe it is used for uploading recipe data form PLC to touch screen Refer to chapter 5 23 fro particular usage 10 Function It contains Function and Function Field which are used for carrying out some special functions These functions are Set Coil Reset Coil Reverse Coil Copy Coil Screen Jump Set Data Copy Register User Input Open Window Close Window Down Recipe Up Recipe Data Block Transmit A
26. S7 200 300 400 Series Software Setting Parameters Recommend PLC Model S7 200 COM Type RS485 Data Bits 8 Stop Bits 1 Parity Check Even Baud Rate 9600 Station No 2 Device Address PLC Address Type Range Format Introduction VB 0 4095 DDDD Data register byte VW 0 4095 DDDD Data register word Internal assistant M 0 255 7 DDD O terminals Data register VD 0 4095 DDDD double word Memo D stands for decimal data TP S7 CABO Wiring Diagram CPU Unit TP series touch screen side FX series RS485 BD module 9P D SUB Male RS485 port 5 wiring terminals 229 Appendix 1 4 Omron C Series Software Setting Parameters Recommend PLC Model OMRON COM Type RS232 Data Bits 7 Stop Bits 2 Parity Check Even Baud Rate 9600 Station No 0 Device Address PLC Address Range Format Introduction Type IR 00000 243 15 DDD BB As terminals and registers SR 24400 25515 DDD BB As terminals and registers PLC As terminals and HR 0000 9915 DD BB registers PLC As terminals and AR 0000 2715 DD BB registers LR 0000 6315 DD BB As terminals and registers Status value of TC 0 512 DDD Timer Counter DM 0 6655 DDDD Data register Current value PV 0 512 DDD Timer Counter TP CQM CABO Wiring Diagram 230 Appendix TP series touch screen side OMRON PLC side 9P D SUB Female 9
27. Software Parts 255 internal objects are used for system to realize special functions The following figure shows part of these functions with high frequency used Bit object PSB Object Function Illustration Name PSBO Normal Closed Coil Set the coil On when frist scan after TP PSB2 Starts up PSB3 Pulse coil with 100ms as period PSB4 Pulse coil with 1s as period Pulse coil with 1 minute as period PSB6 Pulse coil with 300ms as period 1 password open 0 password PSB10 Flag coil of general password closed PSB11 Flag coil of advance password 1 password open 0 password closed 1 password open 0 password PSB12 Flag coil of system password closed 0 communication successful PSB15 Flag of failed communication l communication failed PSB16 PSB30 PSB31 PSB39 Flag of one successful screen scan first scan after downloading first scan after electrifying Close touch screen 211 Software Parts a O 2 O O A Object i Function Illustration Name PSWO PSW PSW20 Read only gt PSW21 Read only PSW26 C Read only PSW27 Read only Read only With PSW28 and PSW PSW28 Total Number of PEW 20 PSW30 ar Hex Read only MA PSW Hex Read ony PSW32 lex Read ony PSW33 Hour Hex Read only PSW34 Hex Read only PSW35 Hex Read only PSW36 Hex Read only PSW40 Pw COM 1 Do
28. Station 1 Object Obiect m O Indirect 172 Software Parts 3 There are nine patterns in Aspect tag page the following 1s part of them Autofind TA D03 Autofind TA OO futofind T A 001 hutoWind T A 004 kutoWind T A 005 4 Please refer to Valve for setting method about Speed Color Position 173 Software Parts 6 10 Motor 1 Click 22 and press left mouse button to add it to the screen as shown below E Screen 2 Double click it to open its property dialog box Then click Object tab the address controlling motor switch can be set in this tab page Other setting have the same setting method with Pipe as shown below Station Device PLC Port WirstaWo Station 1 Object Obiect M O Indirect Cancel pl 174 Software Parts 3 Motor aspect can be set in Aspect tab page as shown below Color Position Lamp f ON Map C DEF Map User Defined Changing Cancel Click Change Aspect button then four maps will appear as shown below S Y Motorl Motor Motor Motor 4 Please refer to previous chapters for introduction about Color and Position 175 Software Parts 6 11 Retort 1 Click w and press left mouse button to add a retort to the screen as shown below MM Screen E x P 2 Double click 1t to open its proper
29. amp Note we ll not introduce Position of the other components as the position dialog box of each component has the same functions you can set freely or refer to the above introductions Next we ll show how to set Animal 10 ae l ONNE e Firstly tick Horizontal then a button shown as S will appear on its right Click it and you can see a dialog box with Station Object and Data Here we take DO as an example Animal Object Format Station Device WirstaNG Station 1 Object Obiect D O Indirect Data Data Word aree Changing the value of DO the component will move horizontally to correspond Vertical has the same method as Horizontal with only changing the direction to vertical Do it by yourself and you can find that the operation is easy 101 Software Parts 5 2 Dynamic Text In the industry control process there may be several status of machine By these dynamic texts the machine can display different status This makes the operation much convenient and can improve the work efficiency E 1 Click icon in the Part toolbar 2 Move cursor to the screen click the left mouse button to place it on the screen click the right button or press ESC key to cancel place 3 After selecting the Dynamic Text double click to open its property dialog box as shown below There are Station
30. and screen name and then click OK to finish the creature Screen Name creen Message m Creating new windows 1 There are also two ways in creating windows Way A I Click window in the project manager to make it turn to highlight color II Click in the operate toolbar 31 Software Parts leuchWin Edit Tool Project Screen DA CS PARK 960 mmm ma I agoto so la RM A EA E A TA Eder o wibo e a ree Right click window in the project manager and then click Insert in the pop up menu lta Project SEEN Right click window 32 Software Parts 2 There will pop out a new window dialog box set the window ID and 1ts name size and then click OK to finish the creature Window i Width 1 60 Name window Height 1 20 Message Cancel 2 2 1 2 Title setting for a screen or a window 1 While creating a project screen window We often give each screen window a different name to identify the screen window There are two ways to modify their names Right click a screen or window in the project manager then choose Property in 1ts pull down menu Project CUE Copy Delete Property Select the special screen and the click in the operate toolbox directly 33 Software Parts TouchWin Edit Tool Project Scroent Og CM PT ARK CEON mmm saI Aol sco wh Easits e LL AOt oO 2D EAS RLU BA pasa S om Olt bo le ae
31. area Refer to chapter 6 9 for particular usage Motor It is similar with motor used in normal industrial control area Refer to chapter 6 10 for particular usage a Retort 14 gt It is similar with retort used in normal industrial control area Refer to chapter 6 11 for particular usage 14 Invert Alarm Information E Invert Alarm Information It 1s specially used for invert alarm With 1t you can set max or min value of each alarm information and 57 Software Parts 58 m Sample Save can type alarm contents Refer to chapter 6 12 for particular usage 15 Map It contains Real Trend Map History Data Map Event Button Display Real Time Event and Display History Event They are used for changing or comparing data as well as recording or displaying alarm event or spring event z Real Trend Map E Observe and compare sole datum or several data by real trend map z History Data Map bE It can picking sole datum or several data to form history data and then show them with curve therefore you can handle changing situation of data clearly Refer to chapter 6 14 for particular usage Event Button It used for page turning confirming and clearing the tables recording events matching History Data Map Refer to chapter 6 15 for particular usage Display Real Time Event S Alarm and display several alarm information When the ala
32. below 2 Click E or from File gt Run Offline you can enter the simulating state The following shows the effect 202 Software Parts As shown above the lamp is red which shows the button value is 0 when you click Control button the button value will be set 1 then the lamp will change as shown below 203 Software Parts 9 2 Simulate Online This function 1s used for reading data from PLC and simulating touch screen actions in PC software with connecting PC and PLC Also this function can help operator save time as the project needed not to download to the touch screen Please pay attention that set right connection between PC and PLC as well as COM port Take the following as an example 1 Firstly place a lamp on the project screen which will controlled by PLC Here we choose Thinget XC series as shown below PE 2 After saving this screen click in the Operate toolbar or from File gt Run online you can enter Simulate Online state as shown below O Register Exit 204 Software Parts 3 Right click on the simulating screen a pop up menu will appear as shown above Pay attention to Com Port and click it then you can see the following window Com Fort unload Port 4 Please set PLC and Download Ports correctly otherwise Communicating will appear in the screen and it can t simulate as shown below Communicating
33. box containing Display Font Color and Position Firstly we introduce how to set Display with the following figure Display Font Color Position Manner f 2001 9 11 for display 3 Please refer to previous chapters for introduction about font color and position tab 156 There are two manner Software Parts 6 2 Clock 1 Click O in Part toolbar and place it on the screen MM Screen T ol Ed Display Font Color Position Sample 12 34 56 Manner e Second f Display f 12 34 56 f Hide 3 Please refer to previous chapters for introduction about Font Color and Position 157 Software Parts 1 Click dE and place a buzzer on the screen with click left mouse button in the screen as shown below MM Screen E E Ps Pay attention to the buzzer this 1s a hidden part meaning it will not display in the screen But 1t will act when conditions are sprung 2 Double click Buzzer to open its property dialog box containing Object Buzzer and Position tabs The following tab is Object in which you can set coil address which is used for springing buzzer Buzzer Object Buzzer Position Station Device WirstaNG Station 1 Object Obiect M O Indirect 158 Software Parts 3 There are two bell modes the first is One and the se
34. can jump to password page Screen Jump Jump Button Color Position Screen ID 60001 caca emp 4 Press Screen Jump button to jump to the password screen 223 Application 6 Press otherwise it will prompt password is wrong as shown below after inputting the password If the password is right it will prompt password is open Opened password Error password s T Prompt after inputting Prompt after inputting correct password wrong password 7 Press Close password pop out the close password dialog box but the operation that has password protection cannot be carried out Closed password 8 Press back button to return to the original screen 224 Appendix APPENDIX connecting methods with popular PLC 1 PLC CONNECTING METHODS The following introduces communication setting and connecting of TP and various popular types of PLC 1 1 Thinget FC XC Series TP Software Setting Parameters Recommend PLC model Thinget FC XC series COM port RS232 Data bits 8 Stop bits 1 Parity bits Odd Baud rate 9600 Station No l Device Address FC ID type Range Format Introduction M 0 383 DDD Assistant point inside W 0 2047 DDDD Data memorizer D stands for decimal data XC ID type Range Format Presentation M 0 7999 DDDD Assistant point inside D 0 7999 DDDD Data memorizer
35. functions for the button and then make the button carry out different functions 22 1 Click Function icon and place it on the screen E Screeni 2 Double click function button or select property after right click it a pop up dialog box will appear The tab page of Function is shown below Button With Function Function Button Limit Color Position Function Pressing Released Set Coil Pressed dd Reset Coll Releasing Reverse Cail Pressing Copy Coil Screen Jump Set Data Copy Register User Input Open Window Close Window Down Scheme Up Scheme Data Block Transmit Anthmetic 139 Software Parts gt Function The function button has four types they separately stand for four states released pressed releasing pressing We could add different function to the four states at one time gt Option It shows that the button s certain status can add the following function operation Set Coil Reset Coil Reverse Coil Copy Coil Screen Jump Set Data Copy Register User Input Open Window Close Window Down recipe Up recipe Data Block Transmit Arithmetic gt Add Click a certain function from All box in the right and then Add button will be sprung Click Add this function will be displayed in the left box showing addition is successful Button With Function Function Button Limit Color Position Function Pressing gt Reset C
36. inverter on the base of original function The following will take Mitsubishi FR series transducer as example to describe 1 Firstly open Touch Win Edit Tool to create a new project Panel Select Panel EA OPSE0 L 2 PC HMI Software Atte 320 234 256 colors Finish Cancel 2 Choose a corresponding display click next 99 3 Choose Mitsubishi FR series inverter in the table take setting as system default and then click next Project Author Remark Back Henk gt Finish Cancel 4 Type name author remark and so on then click Finish to enter the edit screen 214 Software Parts I TouchWin Edit Tool Project Screen File Edit View Part Tool Window Help Pe 88 FARM OCOR ama i mass VNOCOCSCHHR A Og D y egga st Fld 17 El Es ne i S XK et et 4 Project MM Screen ll Alarm Here TP control forward reverse stop of the motor by modifying internal parameters input frequency of inverter At the same time touch screen can display the alarm code output frequency output voltage output current and other status The following will give a detail presentation for the unit Place the Digital Display component on the screen and open its property dialog box From default tab Object you can select object type from the object list Display Digital Object Display Font Color Position Station Devi
37. make mastery easier for your control system Display Various models product size from 4 7 to 10 4 Abundant displays Blue white LCD 4 bits grey scale 16 bits grey scale 256 color support BMP format with vivid screen Multiplicate languages simplified Chinese traditional Chinese English Japanese Korean and so on with font setting freely Expanding capacity Add more screens and data Control Controlling dynamic digital display and monitor bar graphics real trend map discrete continues map and switch Alarming at real time and record history alarm Picking up data with timer or setting condition Setting three grades password limitation Supporting simulate on line off line and configuration function which can simulate operations without connecting TP Communication Double ports communication separately which can connect two different devices simultaneously Driving panel printer directly and make the process low cost and flexible Supporting freedom protocol and drive program compiled by end users Hardware Parts 1 2 Workflow The main operating steps of TP series touch screen are shown in the following figure Simulating TP action in graphics software observing the effect and Installing TP software in PC Editing project graphics in TP software Electrifying TP and connecting PC and TP Downloading project data to TP Electrifying PLC and connecting TP and PLC Communicating TP w
38. press left mouse button on the screen to add it as shown below MM Screen ai x Vertical line shows the current data 2 Double click it to open its property dialog box As shown below the first tab is Trend Source Histroy data map E Trend Source Display 2 ave Color Font Position Add Modify Delete Order Object MinValue MaxValue A A Cancel Add increase objects Modify change address and range of the selected item Delete delete the selected object 183 Software Parts 3 Click Modify button to open History Trend Source dialog box as shown below Histroy Trend Source Trend Data Color Station Device PLC Port Virstahlio O Station 1 Object Obiect lb O Indirect Set data of picking data Data Data word Histroy Trend Source Format Dec C Hex Set min and max values C Float C Unsigned for picking objects The default value are 0 1024 4 From History Data Map gt Display page data total data pick period the place of display position and how to save current data can be set in this tab page 184 Software Parts Histroy data map E Trend Source Display Save Color Font Position Page Data amount of data Data Tre that can be displayed in one Fage Data E mi screen Total Data 10 T Bottom Total Data Total amount of Pick Period 1 Sec None picking data conta When Page Data
39. 4hours running Screen Display Area 480 234 properties Language Setting Chinese simplified traditional English Japanese Korean and others Character Dimension Discretional font Discretional dimension sea oo e Memorizer Cooling Manner Natural air cooling F External Configuratio i 200 0 148 0 44 4 Dimension mm n Cutout Dimension 182 4 134 4 For front panel mm 10 Hardware Parts TPA60 A61 TPA60 L TPA60 T TPA61 T Input Voltage DC20 DC28V Current 380mA Consumption Allowable Less than 10ms Momentary Electrical Features Power cut Voltage Endurance AC1000V 10mA 1 minute signal and time Insulated Resistance DC500V About 10MQ signal and time Communication Port Support RS 232 RS 422 RS 485 Download Port Support RS 232 Operating 0 50 C Temperature Storage Temperature 20 60 C Ambient Humidity 20 85 Non condensing dry bulb Vibration Resistance 10 25HZ X Y Z direction for 30 minutes 2G Interference Noise voltage 1000Vp p pulse duration lus 1 minute Environme nt o Rejection Surrounding Free of corrosive gasses Atmosphere Protect Accord with IP65 Configuration Type 4 bits grey scale TFT TFT black white 256 color 256 color monochrome LCD LCD Screen Size 10 4 Inch z Using Life 50000 hours upwards environmental temperature 25 creen C 24hours running Display Area 640 480 800 640 640 480 properties Contrast Can not adjust Language setting
40. 5 Double click the graphic to open its property window From Polygon Block you can set direction and block value as show below Polygon Block Color Position Direction C Dowr gt Up C Left gt Right C Right gt Lett Block j Cancel 82 Software Parts Polygon Block Color Position Eind Color Ta E E EEEE ack Color Block Color EE ENET a More E cancel amo Here we set Up Down in direction box type 40 in block box and set color as shown above Then you can see the final graphic as shown below MM Screen 83 Software Parts 4 7 Three Dimensional Frame 1 Click gol then press down the left mouse button and drag the cursor to form a rectangle let the left button go to finish painting a three dimensional frame as shown below 2 Drag eight reference points to adjust the height width and size of three dimensional frame 3 Double click the graphic to open its property window for setting color and position Do the following setting and you can see the final effect as shown below Frame Lolor Position Kind Color Fill Color E 4 Eng REGAN Ob HEE E More iw Fill cancel sob 84 Software Parts 4 8 Inserting Map 1 Click Em and press down left mouse button to open the following window after the cursor becomes cross shape Look In E Desktop l pa eee ej Ex my Documents 4 My Compu
41. 5 Siemens 2000 AD E ae 229 l4 OMRON C Serics ai E Maced easel Ea Recast ie 230 12D K OyO S OEE Sara T a a a E A EA aaa ii 232 o DE DYES A a a a aesmnees sacs once ueasecetinens 235 ETA Master k series Pr en E e a LS 237 1 8 Matsushita FP Series PEC lt ai a a a a a a 240 a O AAA A NEA A AEA SEA A 242 TO Bate Eb Seres PEC 243 Elle Visor VE A E a a ta bestudtabeshs 245 TAR Fup SPB SEMCS aeni a a eter a ceaetenctened A ptectienitesed di weriienivest 247 Pals Reyence KY Series PLE sie A ble tectR Geers 249 1 14 Emerson EC20 series PLC 0 c ccc csccescssccsccscesccnscoscesccsscescesscnscescesscescescesscascescesscescasees 250 1 15 OEMax NX7 series Preface PREFACE Essential introduction about this manual Thank you for buying TP series touch screen made by Xinje Electronic Co Lt this manual should be read and understood before attempting relevant operation Purpose of this manual This manual offers guidance and information about how to use TP correctly and maintenance including application situations operations transportation storage installation maintenance etc This manual mainly contains four parts hardware software application and appendix gt Hardware Parts Describing the essential features specifications dimensions installations and communication connecting of TP series gt Software Parts Introducing how to use graphics software TouchWin2 7 and connect it with TP gt Application Par
42. Chinese simplified complex font English Japanese Korean and others Discretional font Discretional dimension Touch Panel Resistance Memorizer Cooling Manner Natural air cooling External l l 311 234 48 Configurati Dimension mm 11 on Cutout Dimension 301 224 For front panel mm Hardware Parts 3 COMPONENT NAMES TP460 L Rear View Tewelfin Tauch Pares TIPE TP460 L INPUT DGe4y SW 200411501116 AAPEA ERLE Power outlet Communication Port Download Port Hardware Parts TP560 561 Series douchin Touch Area Rear View Es Communication Port Tatin Todd Parcial it i my TYPE TP Stil INPO Seay cee 200581 SAA Download Port ral E ima a Ee E Power Input Termimanl Block 13 Hardware Parts TP760 T Communication Port Tias Touch Panal TYPE TE TADET E DP LT Da aa Say P 2010411117 A Download Port E i 5 Power Input Termimanl Block TPA60 A61 Series Rear View Input erminal Block Download Port Communication Port L i Hardware Parts 15 Hardware Parts 4 EXTERNAL DIMENSIONS TP460 L Dimension TP460 L Actual dimensions Unit mm 163 2X111 4X45 Cutout dimensions Unit mm 165X113 165 a TP560 561 Dimension TP560 561 Actual dimensions Unit mm 200 0X 148 0 X 44 4 Cutout dimensions Unit mm 182 4X 134 4 laz
43. FP3 has special control the station number must be 0 Please pay attention to communication setting of PLC when connecting Device Address PLC Address Type Range Format Introduction Exterior input x 0 12F DDH terminals WX 0 12 DD As registers Exterior output Y 0 12F DDH terminals WY 0 12 DD As registers 0 62F Internal assistant R DDDH 90 903F terminals 0 62 WR As registers 900 903 T 0 99 DD Timer terminals C 100 143 DD Counter terminals setting value of timer SV 0 143 DDD or counter Current value of timer EV 0 143 DDD of counter DT 0 9999 DDDD Data registers 240 Appendix TP FP CABO Wiring Diagram Memo NAIS FP series PLC contains FP0 1 2 3 25F 10SH etc all of them can be connected to TP touch screen by program port on CPU or communication port l CPU Unit RS232 TP series touch screen side FPO FP2 FP2SH FPM CPU 9P D SUB Female 5P MiniDin Female FP1 FP2 GP2SH FP10SH CPU RS232 Port 9P D SUB Female TP series touch screen side 9P D SUB Female 5P MiniDin Female O O 3 Memo 241 In FPO series only FPO CXXCXX model has RS232 communication port 1 9 Schneider PLC TP Software Setting Parameters Recommend PLC Model Schneider COM Type RS485 Protocol MODBUS Transfer Frame MODE pale Data Bits 8 Stop Bits 1 Parity Check Even Baud Rate 9600 Station No l Device Address
44. Fill Color Position Graph s filed color is the orginal color after desalted caca emp As shown above the original color is greenish black and ratio 1s 7 therefore the last filled color is light than the original color E Hatch Filling the graph with hatch chose 12 Software Parts Line Fort Fie Fill Color Position gt gt II A O OO O Re a Ww a QO ForeColor La 0 BackColor z cara ao As shown above the left bar is used for setting and the right bar is used for choosing hatch There are 53 kinds of hatch can be chose Also you can set origin forecolor and backcolor at will F Linear Filling the graph with linear gradual change color Line Fort Fie Fill Color Position HA O O E v Jr lv First Color el Last Color L Direct C Hor Top Left Wer C Bottom Right fe Angle 30 Color O Kind As shown above the left window is used for setting and the right window is used for set detail effect Firstly set color of starting point first color and finish point last color Secondly set the middle color freely Thirdly control the transition There are five directions can be selected you can set angle at will after ticking Angle F Centerar Filling the graphic with setting color radially 73 Software Parts As shown below the left window 1s used for setting format and the right window 1s used for se
45. Hardware Parts 6 PORT INSTRUCTION Pin assignments of TP series touch screen communication port TP Communication Port TP Download Port TP Download Port PCs COM Port 1 On the base of above download cable jump out the eighth pin and fifth pin then you can download TP with force 2 Please refer to appendix about communication wiring between TP series touch screen and other mainstream PLC Hardware Parts 7 REGULAR MAINTANCE AND CLEANING Please do not open the rear board by yourself Please do not analyze or rebuild TP series products by yourself Please cut off all the power supply while checking Please do not touch terminals in the electriferous products otherwise it may cause electric shock Please do not insert or pull out cables with power on or draw the cables while communicating otherwise 1t may cause damage of the cables Please periodically check installation and screws to avoid falling off Please use TP series touch screen in the certain environment conditions according to this manual Please keep the product film clean as to keep 1t delicacy Please clean the products with clean cloths and appropriate amount of detergent Cleaning Please use clean cloths to clean the screen Please use cloths with appropriate amount of detergent or alcohol while cleaning Natural detergent without acid alkali is recommended Keep distance from thrill or strong corrosive gas Never spr
46. Object and when its status is Station 7 OFF valve diaplays as Device closed virStaNo O Station Object Obiect ln O Indirect Utter Object When its object s status is M Utter Object ON valve displays as call flow and when its object s Device Puc Port status is OFF valve WIrstaMo D Station 1 displays as stillness Object Obiect ra O l Indirect 164 Software Parts 3 Open Valve dialog box you can set valve manner flowing direction and act mode Object Valve Speed Color Position Act Set lve Manner obj with the status O Set off let the valve User Defined object with the status OFF _ Save Aspect Reverse let the valve Direction object turns to opposite f Normal C Reverse status Instant set ON when Act pressing valve object and Ok Cancel Click Change button to pop out gallery there are 24 patterns can be chose The following graphs are part of them Valve T ROU A Valve T R 001A Valve T R 003A Valve T R 004_A Valve T R 005 A Valve T R OOB A 4 Speed tab page is used for setting flow speed of valve you can set speed range and the current speed as shown below 165 Software Parts cancel toy _ See a After ticking Register there will be pop out a button named click it you can open register window in which address of register can be changed a
47. P D SUB Male Memo A Set OMRON plc in Monitor Run mode Operation change the value in DM6600 to H0201 and electrify afresh then it will operate B Communicating with CPM1A you need to use CIFO1 cable supplied by Xinje Electronic Co Ltd 231 Appendix 1 5 Koyo S Series Software Setting Parameters Recommend PLC Model KOYO Data Bits 8 Stop Bits l Parity Check Odd Baud Rate 9600 Station No l _ Parameters _ PLC Model_ DataBits Stop Bits _ Party Check Device Address PLC Address Range0 Format Introduction Type Exterior input I 0 477 000 terminals Exterior output Q 0 477 000 terminals Internal M 0 377 OOO assistant terminals Timer T 0 177 OOO terminals Counter C 0 177 OOO terminals S O 777 OOO Step terminals R 0 41037 OOOOO Data register Memo O stands for octal data 232 Appendix TP SZ CABO Wiring Diagram 1 CPU Unit DL05 DL105 DL230 DL250 DL350 DL450 RS232 Port Direct Logic series RS232 port 6P RJ 11 Male TP series touch screen side 9P D SUB Female Memo DLOS series port amp 2 DL240 s port amp 2 DL250 portl DL350 s port and DL450 s port2 are all hardware ports of RJ 11 the wiring diagram as shown above 6P RJ 11 Phone Jack 233 Appendix 2 CPU Unit DL250 CPU Unit Port2 RS422 DL250 CPU unit RS422 port 15 PSVGA Female TP series touch screen side 9P D
48. PU unit 236 Appendix 1 7 LG Master k series PLC Software Setting Parameters Recommend PLC Model LG Master k PLC COM PORT2 PORTI protocol sil PRG Slave Data Bits 8 8 Stop Bits Parity Check Even None Baud Rate 9600 34800 Station No i 237 Device Address PLC Address Range Format Introduction Type I t Output PO 0 127F DDDH eee terminals Guard l KO 0 31F DDH ae terminals Internal assistant MO 0 191F DDDH terminals LO ear ED ane relay termials FQ 0 63F DDH Read only T 0255 DDD Timer Terminals C 0255 DDD Counter Terminals Current value of TD 0 255 DDD Timer Current value of CD 0 255 DDD Counter DO 0 5119 DDDD Data register SD 0 100 DDD Step As register 2 Can be extended as register TP LG CABO Wiring Diagram l PORTI TP series touch screen side Master k series CPU 9P D SUB Female 9P D SUB Female 2 RXD 3 TXD 238 5 GND 5 GND 2 PORT2 Master k series CPU RS232 port 9P D SUB Female TP series touch screen side 9P D SUB Female Appendix 239 1 8 Matsushita FP series PLC Software Setting Parameters Recommend Panasonic FP Model COM Type RS232 Data Bits 8 Stop Bits l Parity None Check Baud Rate 9600 Station No 1 Usually we default FP series PLC s station number as 1 but
49. Remark Back Next gt Finish Cancel 28 Software Parts 8 The edit window 1s shown below re ven Pat Tod Yao ee l OM CR PT AGK SCOR maaro wes Peo ee so ee SSA RO SDTV Dc Ae ca A EA EEI Amma MITE BB EF et iasi leet i 0 TEEPA TIE C 9 Select Save In the File menu or click in the standard toolbar to save your project as shown Save Ire E Desktop e E ray Documents d Mw Computer Sony Network Places aa New Folder File name oject Save as Ippe TouchWinProject File twp Cancel You can choose where to save files the auto definition suffix 1s twp 29 Software Parts 2 2 Editing Project 2 2 1 Basic operation of editing screens and windows 2 2 1 1 Creating a new screen or a window Creating new screens 1 There are two ways to create a new screen Way A I Click screen in the project manager to make it turn to highlight color II Click E in the operate toolbar as shown below E Touch Edit Tool Project Screen Fie Edi View Porto Tool Wiskey Hiki Dep gt SP Age e oran Bae Pe HOS oo ha k E AECE TO RoOt o2D0T g Ree Be mA w E E a 5 AELA pm do ee alee Way B I Right click screen in the project manager II Then click Insert in the pop up menu 30 Software Parts Right click Screen 2 The new Screen dialog box pops up as shown below Input screen s ID
50. SUB Female 14 CTS 12 RTS 15 CTS Memo DL250 unit s Port2 combines RS232 and RS422 these two electric ports when using please pay attention to their type setting 3 CPU Unit DL430 DL440 DL450 CPU Unit Portl DL350 CPU Unit Port2 RS232 DL350 405 series CPU RS232 port 25P D SUB Female TP series touch screen side 9P D SUB Male 234 Appendix 1 6 Delta DVP series Software Setting Parameters Recommend PLC Model Delta DVP COM Type RS232 Data Bits 7 Stop Bits 1 Parity Check Even Baud Rate 9600 Station No l _ Parameters EA COM Type ES Spin Pasty Check Banat Device Address PLC Address Range Format Introduction Type Exterior input xO 0 377 000 j terminals Exterior output YO 0 377 000 j terminals Internal assistant MQ 0 1279 DDDD relay s 0 1023 DDDD Step terminals T 0 255 DDD Timer terminals C 0 255 DDD Counter terminals D 0 1279 DDDD Data register Current value of TD 0255 DDD timer Current value f CD 0255 DDD counter Memo D stands for decimal number O stands for octal OX Y M Sall could be extend as registers 235 TP DVP CABO Wiring Diagram TP series touch screen side Delta DVP series 9P D SUB Male SP MiniDin Male Memo Delta DVP series PLC contain DVP 14 24 32 60ES00 and DVP XXESO1 etc model all can be connected with TP touch screen by program communication port on C
51. TouchWin Select Destination Location Where should Touchin be installed Setup will install Touchin into the following folder To continue click Mext If you would like to select a different folder click Browse Program Files ThingetiTouchyyin Browse i least 50 2 MB of free disk space is required Click next all along until completing installation and then click finish After installation the following icon will appear on the desktop Touchin Edit Tool 23 Software Parts 1 2 Components Of The Software Screen Run Touch Win Edit Tool from Start gt All Programs gt TouchWin or double click TP icon on the desktop Then Create a new project and you can see the interface as the following figure Menu TouchWin Edit Tool Project Screen File Edit View Part Tool Window Help we ndard Toolbar E ed Project MM Screen OX Standard Toolba E E Screen j AED window eats can aa Ai Alarm EEN A li Print aja A AZ O o los le Sees A A 2 Standard EJ Ia AIRES Part Toolbar E A oe Bae ke ee Se Part pe ee at ee ee vPJAS 4 S EOR BEB PE Bai 1 dF Ho ee DEAN Graphics Toolbar NOOCOCeOR k Panel Toolbar ES Align FA FEE Align Toolbar Zoom S 100 lg Operate E Status E Zoom Toolbar Operate Toolbar Status Toolbar E 1e760 1 Screen Edit Area Project Manager PLC Port Thinget xC Series Download Port Thinget C Series a 3 4
52. WouchWvin TP Series Touch Screen User s Manual Ying s Electronic Co Ltd wWouchWin Human Machine Interface PREFACE l TP Series o Touch Screen SAFTY PRECAUTIONS 3 User s Manual HARDWARE PARTS 4 SOFTWARE PARTS 21 APPLICATION PARTS 221 Version 2 0 APPENDIX 225 Revision data 11 2007 ee This manual contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning triangle Please obey the essential electric operation rules which have not indicated in this manual DANGER la Please comply with these notices incorrect handling may cause system working incorrect or abnormal Severely may result in property damage This device and its components may only be used for the applications described in the catalog or the technical descriptions and only in A connection with devices or components from other manufacturers which have been approved or recommended by Thinget This product can only function correctly and safely 1f 1t 1s transported stored set up and installed correctly and operated and maintained as recommended Thinget Electronic Co Ltd All rights reserved The reproduction transmission or use of this document or its contents is not permitted without express written authority Offenders will be liable for damages All rights including rights created by patent grant o
53. al Input Text Input Set Data Digital Keyboard ASC 41 ACFKE9 AYR Keyboard User Input Bar Dynamic Map Call Window Window Button Down Recipe Up Recipe Function Button Function Field Discrete Column Map and Continue Column Map from left to right Part Toolbar 5 1 Text 1 Click A icon in the part toolbar 2 Drag cursor into the screen click the left mouse button to place the text click the right button or press the ESC key to cancel your place MS Screent 3 Double click the left key or choose icon there will pop out a text setting dialog box aie RARAJ AVR Display This contains Content Frame and Align mode boxes 97 Software Parts Display Font Color Position Content Align Hor Align Wer Tent Left C Top f Center e Middle C Bight C Eottom Cancel ip Tick Aspect and click Changing Button to open the following window Gallery Gallery Gallery1 there are 30 kinds of HD fo oI Aspect TRA 000 Aspect TR 4001 Aspect TRA O02 Aspect TRA 00 white and black pattern J LI Lo Aspect T_R_4 004 Aspect T_ R_B 000 spectT_R_B 001 spect T_A_B_ OO multicolor pattern Gallery 2 there are 3 kinds of Cancel Note All the colors of these patterns can be changed by user containing the white and black pattern H
54. are less than Total Data you can use This Regist was used to control Pick Event Button to switch displaying of different data i Current Data The Current data will place from PS W500 to Pick period interval between Po S06 ae two picking data Cancel Ticking current Data then the current data and time will place from PSW500 to PSW506 default save address If you want to modify save address please click a and modify address in the pop up dialog box The current data will not save without ticking current data capital address Object Station Device WirstaNG Station Object Obiect Psw 500 Indirect Cancel 185 Software Parts 5 Save tab page can be used for storing picking data and it set Auto Locate as default Also you can set save address with ticking out Auto Locate and modifying object address as shown below Histroy data map Trend Source Display Save Color Font Position Object Obiect PFW 256 Indirect cancel tm 186 Software Parts 6 15 Event Button Event Button 1s used for viewing history data or multi page data with operating the cursor of data save components to cooperate with History Data Map and History Event 1 Click and press left mouse button on the screen to add it as shown below E Screen a El x Fs Event Button Event Button Color
55. assword None Nomal Advance System a Limited By Coil ro Cancel If you tick Limited By Coil it will be available in the case that setting coil has been sprung Then Click MO l a _ The following window will appear Object Station Device WirstaNG Cl Station 1 Object Obiect M O Indirect 3 Concrete setting for function component gt Set coil Set 1 to certain relay or bit Click Modify to enter its setting dialog box then modify the object address which take MO as default as shown below Function Set Coil Object Station Device F wirStabO O Station 1 Object Dbiect m o I Indirect gt Reset Coil Set 0 to certain relay or bit Setting method is as same as its of Set Coil 142 Software Parts gt Reverse coil Reverse certain relay or bit alternating 0 1 of the coil Please refer to Set Coil for setting method gt Copy Coil Copy the source coil s data to the object coil Please refer to Set Coil for setting method gt Screen Jump Make the screen jump to the appointed screen Click Modify and then set screen ID in the pop up window as shown below Screen ID Jump to C Start Screen C Previous Screen Screen ID gt Set Data Set the appointed value to the appointed object Click Modify and then modify the object address and set data in the pop up d
56. ate Button Color Position Station Device PLC Port WirstaWo Station O Object Obiect Forward 0 The following mainly introduce object type in object tab page you can refer to other components for more information about other tab pages gt Forward Stop corresponds to forward status or stop status of inverter ON stands for forward OFF stands for reverse and stop gt Reverse Stop correspond to reverse status or stop status of inverter On stands for forward OFF stands for reverse OFF stands for forward and stop gt Run Status correspond to running status of inverter On stands for running OFF stands for stop running gt Rolling status correspond to rolling status of inverter ON stands for forward OFF stands for not forward gt Alarm correspond to current internal alarm code of inverter 4 Please refer to previous chapters for introduction about relevant properties 219 Application APPLICATION This chapter takes connecting communication of TP series uch screen and password setting as examples to describe how to operate TP in plications 1 TP series operate methods 1 1 TP series online communication 1 2 TP series touch screen password 221 Application 1 TP SEREIES OPERATE METHODS Take TP s communication and password application as examples 1 1 TP series online communication After the screen s data download is finished cut the power off and pull out the sc
57. atter Fold Map E Object Display Color Position Display Object Table Add Modify Delete 1 a 0 2 AB Move Up Move Down Cancel Apply 132 Object list Add a new object Modify the selected item Delete an item Move up the selected item presenting as the sequence of abscissa Move down the selected item presenting as the sequence of abscissa Software Parts 3 Double click items in the list or click Modify button to pop out its property dialog box Then the display objects can be set in it Fold Object Device WirstaNG O Station 1 Indirect Data word The following is Display tab page Scatter Fold Map Object Display Color Position Degree Format Set data format C Dec Range of Full ut CO Hex digital display C Float u f Unsigned Patten is the default Fold Column pattern cancel amo 153 Software Parts 5 26 Continue Cloumn Map Continue column graph s horizontal axis takes continue registers as its objects Display each register s value in the form of graph It has the same usage with Discrete Column Map the only difference is that one is for displaying discrete data and the other is for displaying continue data 1 Click Ma and place it on the screen MM Screen E af Pe 2 Double click its property dialog box and set the head address of digital display in Object tab pag
58. ay the detergent directly onto the screen Please do not touch the screen too hard while wiping otherwise it will destroy the screen Caution Dispose of the product as industrial waste when it comes into castoff Software Parts SOFTWARE PARTS Application of TP series touch screen editor software 1 About Graphics Software 2 Getting Started 3 Introducing Menu 4 Making Graphics 5 Basic Components 6 Special Components Display 7 Alarm Window Print Window 9 Simulate Functions 10 Special Functions 21 Software Parts 1 GRAPHICS SOFTWARE This chapter describes TP series touch screen software s project screen and its components and the components of toolbox template in addition 1 1 Installing The Software 1 Operating System Windows98 2000 XP ME 2 Installing screen editor software as follows Double click setup exe from installation file Click next or yes all along until user information dialog box appears Input user name company name and serial number The serial number is Thinget TouchWin note if the letter is incapital or not and the blank then click next ie Setup TouchWin User Information Please enter your information User Mame Organization Serial Number 22 Software Parts Select the target file for software installation the default address is C Program Files THINGET Touch Win ie Setup
59. b with various aspects you can add Text set align manner change aspect of instrument and so on instrument Object Display Set Font Color Position r Manner oe Fes Align Hor Align Yer C Left C Top f Center Middle C Bight O Bottom Changing Cancel Appli Click Changing button at the bottom of Aspect box then you can open gallery for choosing suitable aspect There are 6 patterns can be chose as shown below Also you can select color freely in the tab page of Color dl Pointer _T Ol Pointer_T 02 Pointer _T 053 Pointer_T 04 Pointer T 05 Pointer T 06 4 From tab page of Set you can set direction pointer thick main scale slave scale alarm data danger data as shown below 162 Software Parts instrument Object Display Sel Font Color Position Direction Data Set Order Reverse Ree Graphics Min Pointer Thick M Up Danger 390 M Up Slarm al M Down Alarm 20 Slave Scale W Down Danger 10 Main Scale 5 Please refer to previous chapters for relevant introduction about Font Color and Position 163 Software Parts 6 6 Valve 1 Click S and press left mouse button to Place it on the screen as shown below MM Screen E E Pr 2 Open its property dialog box Valve Object When its status 1s ON Object Valve Speed Color Position valve displays as open Valve
60. ce Pic Port VWirStahlO O Station O Object Obiect m Code J 215 Software Parts gt Alm Code Correspond to the alarm codes inside the inverter You can use Chinese to display the alarm message gt Set Frequency Correspond to the set of inverter s frequency gt Out Frequency Correspond to the output frequency of the inverter gt Out 1 Correspond to the output current of the inverter gt Out V Correspond to the output voltage of the inverter gt Parameters Correspond to the different parameters inside the inverter the you can appoint a certain pa rameter in the inverter and display 1t on the touch screen gt Code Correspond to the different command codes inside the inverter you can assign a certain order code to control the frequency and make 1t do the corresponding action Click Display and set 1t with screen clue and technical requirements as shown below Display Digital Object Display Font Color Position Format Bit Length C Dec H Total 5 Float Float 0 W Aspect Align Hor Align er T 00000 Eel Top Center Middle Changing le Right C Bottom Cancel 216 Software Parts 2 Place E inverter alarm information on the screen as shown below MM Screen The object tab of Inverter Alarm Information is same to digital display s The following describes relevant parameters of Display tab Variational Text Object Display Font
61. cel Apply 76 3 Software Parts Color There are 256 kinds of selected color which are only for the borders of rectangle Its setting interface is similar with pie Fill It has the same setting with pie please refer to above chapter Position Please refer to P78 as its setting is as same as a pie Examples of rectangle filling Here we only show the popular setting examples E ae 23 Pn Her wae ead 77 Software Parts 4 4 Ellipse Please refer to the instruction of Rectangle as Ellipse has the same operation with Rectangle Note only the color option is a little different as there are usually Fill Color and Frame Color can be selected If there is no y in the box before Fill just Frame Color can be chose As shown below Ellipse Line Color Fill Position Elnd Color ia HACE rame olar A E z Lin tt EL More cancel tm Examples of ellipses 78 Software Parts 4 5 Fold Polygon 1 Click i in the Draw toolbar and press down the left mouse button to confirm the position of acme 2 Let the left key go to confirm the second acme If you increase the acme number please repeat doing this 3 Double click at the end acme to finish drawing polygon MN Screent O A 4 The diversion of fold and polygon The default setting is Fold while it will connect the first acme and the last acme automaticall
62. cond 1s Continue Do the setting in the tab page of Buzzer as shown below Object Buzzer Position Bell Mode Continue Cancel pl 4 Refer to previous chapters for relevant setting information about Position 159 Software Parts 6 4 LCD Light Lamp 1 Click E and press left mouse button on the screen to add it As shown below MM Screen 2 Double click on the screen to open its setting dialog box containing Object and Position tabs Object is mainly used for setting coil address that control the LCD light LCD Light Control Object Position Station Device E WirstaNO Station 1 Object Obiect M 0 Indirect Cancel ppal 3 Please refer to previous chapters for relevant introduction about Position 160 Software Parts 6 5 Instrument 1 Click and press left mouse button on the screen to add an instrument as shown below MM Screen E alt d 2 Double click the instrument in the screen to open its property dialog box As shown below the first tab is Object which you can modify data address that needed to display in instrument Instrument Object Display Set Font Color Fosition Station Device jsEefsmid T WirstaWo Station 1 Object Obiect E O Indirect Data Data Word Cancel 161 Software Parts 3 With modifying Display ta
63. creen will close the black lamp or jump to the assigned screen you can only choose one from the two operations You can set latency time as well as canceling screen save When you click shown screen you can type screen number in the blank box to assign screen which you want the TP jump to Alternation Project Set Color Font Froject Fara Alternatior Clack Panel Device iw Change Screen Control Station Device PLC Port WIrstaNO Station 1 Object Obiect E O Indirect Station Device PLC Port WIrStaNO Station 1 Object Obiect E O Indirect Cancel Change Screen Control PLC can switch screen by modifying the register s value After ticking it choose the suitable Device PLC port or Download port Station and Object 43 Software Parts Object is used to set register of PLC which assign the screen number as shown above the object is DO it means that screen number is determined by the value in DO of PLC Report Current Screen ID input current screen No into certain register and transfer the status of panel to PLC Pay attention to that there is an Indirect box behind object it is similar with the function of indirect addressing After ticking it you can see the following change Object Object Obiect E O gt Obiect E O Indirect Click DO to open the following window Indire
64. ct General Aspect Color Position Button Operate 4 kinds of Button Operate as same as Button Twinkle Status 3 kinds of twinkle as Lamp Stop ON OFF Set Twinkle Speed as Lamp Twinkle Speed a y Default setting has no password You can set Password Limit password with three grades a e f None Normal Advance system They are available only after you type right password Cancel 4 Aspect Button With Lamp Object General Aspect Color Position Set tand th et aspect and you can preview the Aspect display in the screen window Change Aspect User Defined C Pressing Oo Ele Save Aspect Use Text l about Use Text introduced before Please refer to relevant information Left Font Center e Middle On Right Bottom E Click Change Aspect to open the following window 112 Software Parts Gallery Gallery There are two galleries LampButton_T_Circle LampButton T_Circle Gallery 1 with 24 patterns Gallery 2 with 4 patterns LampButton_T Circle LampButton_T1 CC 4 LampButton_T_C_A_ O 4 5 Please refer to Lamp and Button to get relevant introduction about Color and Position 113 Software Parts 5 7 Screen Jump This function 1s used for jumping among different screens 1 Click ig and place it on the screen right click or press ESC to cancel placing MS Screent
65. ct Object tie pas Station Device PLC Port WIrstaNo Station 1 Object Obiect ip 10 p Indirect Data Data Word ll caca amp Indirect Object Object Times Object Format f Dec C Hex C Float C Unsigned Cancel Object is used for save address offset as shown in the above figure set S decimal in D10 1t means 44 Software Parts current screen ID is saved in D 0 D 10 namely saved in D 0 5 D5 In Data box you can choose Word of Dword double word In Data dialog box you can choose data format from Dec Hex Float and Unsigned Also you can set Times if still set 5 in D10 3 in Times box it means that the address stored is D 0 3 D 10 D15 reser Se Color Font Project Fara Alternatior Clock Panel Device W lse RTC Station Device PLC Port WirstaWNo Station 1 Object Obiect E 11 Indirect TP series touch screen set clock inside as shown above this function can educe and save the current time Tick Use RTC set device station and particular address in the device As shown in the above figure storage current time in D11 ofthe device with PLC port station NO 1 The function of Indirect is as same as described in P46 This manual will not introduce this function in the following chapters please refer to P45 for detail introductions 45
66. cursor when it becomes hie RARAJ HY Let the mouse s left key go to fin ish changing the size Polygon x Way 2 Line Color Polygon Fill Position Position Size eN Choose position in the property dialog box input the object s horizontal width and vertical height in the Width and Height then click OK Height Animal Horizontal Vertical Lock Zoom Ratio Cancel 87 Software Parts 4 10 Moving Object The following describes how to move maps and objects eA ie AFR BI S HM Choose the map or object you want to move ei RRA AYR Move the cursor to the map or object then fine cursor will become fe ie AC FREI 5 AYR Press down the left mouse button and drag the cursor to the aim position ei AFBI HY Let the left key go to confirm the position of maps or objects Rectangle Way 2 Line Color Fill Position Choose position in the property dialog box ere choose the coordinates you want the neg coordinates norm is in the up left Animal Horizontal Vertical Lock Zoom Ratio 88 Software Parts 4 11 Cut Copy and Paste for the selected object The following describes how to cut copy and paste a graphics or an object MM Screen 1 Choose the one you want to copy c E 2 Click Cut tb or Copy in the toolbar 3 Click Paste al in the toolbar Short
67. cut key as shown below Cut Ctrl X Copy Ctrl C Paste Ctrl V 89 Software Parts 4 12 Public Unit and Private Unit In order to improve the work efficiency we offer Public Unit and Private Unit Public Unit lets one or more units in the current screen be used by all the screens Private Unit has the opposite function with Public Unit 1t can be used by the current screen only Example Aj We create two screens in all In screen 1 we add a rectangle other units and components also can be used and choose it just as the following mapo MM Screen mE Then we click the Public Unit we will MM Screen find in same place of screen 2 1t adds a rectangle automatically 90 Software Parts MM Screen W Screen If we only want to keep the rectangle in the second screen we can use Private Unit Choose the rectangle in screen 2 MM Screen MM Screen Then click Private Unit button ES you can find that only screen 2 has a rectangle and in screen it disappears 91 Software Parts 4 13 Lock Set an object on the screen and right click it then you can see Lock in the pop up menu Bele e Property Delete Save Click Lock then the object will be locked and 1t can not move or zoom Please pay attention to the locked object that the eight reference points become small rectangles If y
68. dress PLC Address Range Format Introduction Type 0 63 Exterior input terminals 0 63 Exterior output terminals 0 63 Internal assistant terminals 0 255 Special assistant terminals 0 511 Timer status 0 255 D D Counter terminals 32768 33279 D WX 0 63 D WY 0 63 D WM 0 63 D WL 0 255 D 32768 33023 D O O O O O O op 0 8191 E Data memory TW AS 0 511 Timer register CW 0 255 Counter LD 0 10000 D SD 32768 33023 D TP SPB CABO Wiring Diagram TP series touch screen side Fuji SPB side 9P D SUB Female 8P D SUB Male 248 Appendix 1 13 Keyence KV series PLC TP Software Setting En Parameters Recommend Model ES am Program Port COM Type RS232 Data Bits 8 Stop Bits l Parity Even Check Baud Rate 9600 Station No 1 Device Address PLC Address Range Format Introduction Type R 0 999 D Coil terminals DM 0 8000 D Data memory TP SPB CABO Wiring Diagram TP series touch screen side KV side 9P D SUB Female RS232 port 5 GND 4 5G 249 1 14 Emerson EC20 series PLC TP Software Setting Parameters Recommend EC20 Model COM port RS232 Data Bits 8 Stop Bits l Parit Baud Rate 19200 Station No l Device Address PLC Address Range Format Introd
69. e The following take DO as an example Continue Fold Map Station Device PLC Port WirstaWNo Station 1 Object Obiect E O Indirect Data Data Word Lancel 154 Software Parts 3 The following describes the property of Display tab page Data Number means the total number of continues data Range set the range of digital display the default format is None and the default pattern is Column graph These setting can be changed by yourself Continue Fold Map Object Display Color Position SUPP Data Format Number C Dec H Regs Hex C Float Unsigned f Column Cancel Apply 155 Software Parts 6 SPECIAL PART DISPLAY Display components are very useful in the project making process Here we take a separate chapter to illustrate each component s usage and operations As shown below from left to right are Data Clock Buzzer LCD light lamp Instrument Valve Pipe Pump Auto Wind Motor Retort Invert Alarm Information Real Time Map History Data Map Event Button Display Real Time Event Display History Event Sample Save CASERO O p g a le bt Be amp 6 1 Date 1 Click FE in the Panel Toolbar to add it to the screen as shown below MM Screen E a E3 Pe 2 Open its property dialog
70. e button click your right key or press ESC to cancel placing 3 Open property dialog box containing property pages of Object Operate Button Color Position Now we introduce property page of Object firstly As shown below It s content is as same as Lamp s and the button is also a double status part The differences between Button and Lamp Button is used for controlling while not displaying status of the object Lamp is used for pointing while not controlling the status of the object Button Station Device PLC Port WIrStaNo Station 1 Object Obiect Ina a Indirect 4 The following figure shows the tab page of Operate with the default status Set ON 108 Software Parts Button Button Color Position Button Set ON while pressing w SetON SetOFF C Reverse On Instant Set OFF while releasing Reverse relay status Set OFF for relay status Set ON for relay status Cancel 5 Following below 1s Button tab page containing Password Aspect Use Text and so on Button Normal Advance and System are Password available only after None C Nomal C Advance System setting Password in ner wi Hide Button File gt setting Nomal Change Aspect Use Text User Defined Content Set content font and of li button C Press Save Aspect Font e y display
71. e ea A AA A EAE aa 61 O a E A A II IN A A II A A AEE EN 61 30 OMA a O OS 62 4 MAKING GRAPHIC Sy sisi a ta 63 ASE E O A A II Ret 63 RA 67 A See eee en Ser SE eee an Ser See eee ee oer Se eee ee er ae 76 TAS sd 78 A PO PAN ciones 79 A TONDO A II IA A A a a 82 Ae Tires Dimension aL TAM dd lo tl dad dd 84 4 8 Insertine Mo 85 ToC amore Dimension 87 IN OD cr a E A E 88 Aoi Cut Copy and Paste forthe selec dd A e NN 89 4 12 Public Unit and Private Un ansioso ii i e E E EE TETE TETEE 90 SN O A A A 92 ANA MOVIDA ati E 93 AAA A o te te tet N 95 5 BASIC COMPONEN Ts A A a 97 O A O O A A S A AES A dan dtaterdets 97 A A A A A T 102 3 Vaa onak TEX enana tien acdaiales Masten serauae ima ened Nasi anda 104 ita ode letal 105 B E In A aca means ateNeaaaat eat 108 SOPUN EAN eects A ia 111 A S UMD 20sec Sia E E ties tat A anual eu tateeat 114 5 8 Digital Display A o eon ead uae 116 DD NS hc hic T TE Be ania TE EE TE Banco Bion TTET 118 A 119 A SEED a a das sate T a o o o 120 zo MECO tap ter nto ii ptos ad 122 A A A O A A O AEE EE 123 UA MITA UE DO ias 125 EAO bX es a leer ae ene ae etm eee Se eee oe ee en ee ee ee ee 126 LO USE el 2 Sacre nape enna Nt earn o arent re 127 ST Bar A ecco se aon a A al Ron sk aon al ans aon a en aaa 128 Dl Oo Vila dida 130 519 Cal WING OW satis ass che sist a iii edo ia iia ie 132 3 20 Window DUO lil lite 134 O BG ra RECE EPA Re eee SO Re SO A A II A 135 2 U EREE 0 lt AE en DE i ented AR E e
72. e software can store the names of these projects automatically to help user find these more convenient Instead of finding the project s paths click their names can open it to modify 12 Exit Different from Close Exit means exit from TP edit tool If you have not save the modified project before exiting the software will pop out a window to make sure if you want to save This operation can protect you to avoid losing project Software Parts 3 2 Edit Edit menu is used for carrying out operations of components This menu contains Cut copy 29 66 paste public unit and private unit p p p 2 TouchWin Edit Tool Project Scree File A View Park Tool Window Help ry Cut Chri A Copy Chrl 2 Ss Ed i Public Unit 100 z Fy een i screen k Screenl 1 Cut cc de 9 Removes the components from the project and places it on the clipboard To accomplish this select component s then click cut under the edit menu you may also right click the component and then choose cut in its pull down menu 2 Copy c6 Ena Copy the component s to the clipboard To accomplish it select component s then click copy under the exit menu you may also right click then component s and then choose copy in its pull down menu The differences between Copy and Cut are that when cut component s it will disappear while when copy component s
73. ective measures at once to solve the problem Press OK to close the alarm window 198 Software Parts 8 PRINT WINDOW This chapter introduces the essential operation of Print Window 8 1 Create A New Window It is a bit address message of PLC to control the pop of print window and spring the print action The window s content is the print content 1 Create a new window It is similar to creating a new window So it has two ways A OClick Print in the project manager with the left mouse button to make it turn to highlight color 2 Click new icon lt a in the Operate toolbar 2 TouchWin Edit Tool Project Screent File Edit View Part Tool Window Help EA ot Asa dA YO BE Be Fe SNOOCOCPORM k MO cs ime Bae S 100 Hi who MM Screent B Insert a window in the project manager The following are the details Click the window in the project manager with the left mouse button to make it turn to highlight color Then right click it and choose Insert in the pop menu x Project Screen i Print insert 2 There will pop out a new print window dialog box Set its name width and height spring object and print direction Then click OK to confirm setting 199 Software Parts Print Window nido A register bit of PLC Take MO as an example when MO 1 the print Message Height 120 window pops at the same time prints the window s content Whe
74. elect 5 from the Draw toolbar and draw the line by clicking at the starting point and dragging the line to the finishing point Please press ESC or right click your mouse to cancel the operation MM Screen E ES as ee Starting Point Finishing Point 2 Change its position drag and drop its size rotate 1ts angle and so on 3 Click the straight line to choose it as shown above then double click your mouse or click in the Operate toolbar also you can right click your mouse to open the pop up menu and choose property then the following dialog box appears Software Parts Line Line Color Position Here you can choose how Pattern Thick thick you want your line to be the input value can be integer between 0 255 Light Cancel 3 Setting Color There are 256 kinds of color Only black and white can be chose when the touch screen is unicolor line E Line Color Position Kind Color More Color m NM MAA EE MAN Cancel pp 4 Setting Position 64 Line Color Position Position Size A width 222 Y Height E Animal Horizontal Vertical Lock Zoom Ratio cancel tm Position set the coordinates of the start point Software Parts a Size In its box Width points to the horizontal length of the line and Height points to the vertical length of it Animal se
75. er can be set Real Time Event Aspect Event Font Color Position Name Information Rows 3 width 195 Align le Left C Center f Right Hit Cancel ppl 3 In Event tab page you can set spring address information and others Also you can add several items of event information as shown below 189 Software Parts Real Time Event Aspect Event Font Color Position Add Modify Delete Order Object Alarm Message AA Over volt Click Modify or double click the alarm information in the first line the following dialog box will appear Event Source Call Infomation Station Device giem WirataNiQl O Station 1 Object Obiect M O Indirect Modify the alarm information in Information tab page as shown below 190 Software Parts Event Source Coil lnforatior Cancel Apply 4 Please refer to relevant chapters for introduction about Font Color and Position 191 Software Parts 6 17 History Event It is similar with Display Real Time Event The difference between them is that Display Real Time Event displays the current status of data source and History Event can display and save them 1 Click E gt and press left mouse button on the screen to add it as shown below E Screent Ea fx Ah 2 Double click it to open its property dialog box The following is A
76. he machine can display different status While the dynamic text can only display 16 kinds of status and 1t will has less advantages in these places where need more status indications Now the Variational Text can fill this need It has no difference with dynamic text in usage however the display content of Variatioanal Text can be added while Dynamic Text 1s fixed with 16 kinds of status as shown below Variational Text Object Display Font Color Position Add new content Delete content Content display area Align Ver l Piven Align pattern Middle Bathon Change aspect 104 Software Parts 5 4 Lamp In the operation process in order to display clearly which operation 1s being taken or which status the machine is in Lamp offer fast way for the operation and monitoring 1 Click wy gt icon in the Part toolbar 2 Move cursor into the screen click the left mouse button to finish placing the lamp Click the right button or press ESC key to cancel placing MS Screent i m x 3 Open its property dialog box containing Object Lamp Twinkle Color Position The first tab is Object as shown below Lamp Object Lamp Twinkle Color Position Station No Spring Coil 105 Software Parts Note Click Object box to open its pull down menu and then choose the object type and its value In As show in the right i
77. ialog box as shown below Function Set Data Object Station Device VWirStahlO Station 1 Object Obiect E O Indirect Data Data Word Set Data 0 Cancel gt Copy Register Copy the source register s value to the object register Click Modify and then modify address and data type in the source register and target register as shown below 143 Software Parts Function Copy Register Object source Register Station Device PLC Port virStaNo O Station 1 Object Obiect E Indirect Data Data word Target Register Station Device VWirStahlO O Station 1 Object Obiect D O Indirect Data Data word gt User Input Input button codes the codes are in the form of ASC Click Modify and then a pop up window will appear as shown below Key Code Input Rey Code O 144 Software Parts gt Open Window Open the appointed window by the window ID Click Modify and then set window ID and open mode in the pop up dialog box as shown below Open Window Window Position window ID Cy Open Mode Hide f Show f Indepand gt Close Window Close the appointed window by the window ID Click Modify and then set window ID in the pop up window as shown below gt Down Recipe Download the recipe data touch screen etc to the device data PLC Click Modify and then a dialog b
78. ilar with rectangle containing line weight color position and filling pattern Fold Polygon A It is used for protracting Fold or Polygon and its setting contains line weight color position rotary angle and so on Polygon Block It is like a container you can set block value color direction and so on Ol m Frame It is similar with rectangle but it has third dimension as its effect ion is three dimensional Also you can set its color and position 59 Software Parts a Map 66 E 22 It is used for adding bitmap file into screen and it only support suffix bmp Option Grid Size Move Size Fi Show Size 10 Auto Save Period Minute Communicate Default Fart COM Optimistic Viena Default Ratio 100 OF Cancel As shown above there are Grid Size Auto Save Communicate View in option dialog box gt Grid Size Move Size the least grid number of moving object Show Size setting the density of grid in the screen the smaller of the value you set the more dense the grids are gt Auto Save With this option you can set time of Auto Save to avoid losing operation Also you can save project s manually gt Communicate You can set default port from COM1 COM16 for downloading gt View Set default view proportion namely scaling Normally the default ratio 1s 100 60 Software Parts 3 6 Window
79. ing 0 50 C Temperature Storage Temperature 20 60 C Ambient Humidity 20 85 Non condensing dry bulb 10 25HZ X Y Z direction for 30 minutes 2G Environmen i i Interference Noise voltage 1000Vp p pulse duration lus 1 minute Rejection Surrounding Free of corrosive gasses Protect Accord with IP65 Type CCFL 16 rank TFT TFT Screen Size 5 7 Inch 5 6 Inch Using Life 50000 hours upwards environmental temperature 25 C 24hours running S pee Display Area 320 240 320 234 Contrast Adjustable by regulation Can not adjust properties i resistance Language Setting Chinese brief simplified complex font English Japanese Korean and others Discretional font Discretional dimension Touch Panel Digital matrix touch Memorizer Cooling Manner Natural air cooling External l 200 0 148 0 44 4 mm Configurati Dimension mm on Cutout Dimensions 182 4 134 4 mm For front panel mm Hardware Parts 1760 series series Input Voltage DC20 DC28V 280mA Allowable Momentary Less than 10ms Electrical Power cut Voltage Endurance AC1000V 10mA 1 minute signal and time Insulated DC500V About 10M signal and time Features Resistance Communication Port Support RS 232 RS 422 RS 485 Port Environment 10 25HZ X Y Z direction for 30 minutes 2G Interference Rejection Noise voltage 1000Vp p pulse duration lus 1 minute Using Life 50000 hours upwards environmental temperature 25 C 2
80. it will still exist 3 Paste E Place the contents of the clipboard at the insertion point it is used to match Copy and Cut After clicking Copy and Cut you can click Paste to displace or copy the original component s ao l 4 a Public unit It is used for applying a certain component to all the project screens To accomplish it click public unit under the edit menu also you may right click on the components and choose public unit in its pull down menu 5 Private unit gt It is only used after a certain component that has been set public It has the opposite function from Public Unit and it can be used in the current screen only When use it select a certain component click Private Unit under the edit menu you may also right click the component and choose Private Unit in its pull down menu After accomplishing this component will be only saved in the current active screen and deleted in other screens 51 Software Parts 52 The View menu is used for display the toolbars It contains Standard Status Project Paint Zoom Status Change Operate Part Align Advance Advance2 Panel Among these Advance and Advance 2 is in grey color as shown below meaning that they are not sprung They are available when TouchWin Edit Tool has advanced function In general the default setting will show all of these components to convenient operation
81. ita PPO FP1 LS Master k CPU Direct LS Master k CNet Facon M0 m4 Com Para 3600 8 Odd 1 E 4 Set communication parameters in the following figure and click ok to confirm Then click Next to enter download port setting Communication Parameter Baudrate Data Bit C 4600 C 38400 C 7Bits Spits Stop Bit C 19200 C 187500 f 1Bi C 2Bits Parity check None f Odd C Even Mall Communication Time O MSEL W SendData Vir Station Retry times E Cancel 26 Software Parts 3 5 Set COM parameters of download device please refer to above method Please select port Download Device Unuse Downlad Port Thinget aL Seres Thinget FC Series Mitsubishi Fs Series Omron CRM COR Seres Omron CP1H Series Siemens 57 200 Seres Siemens 57 3007400 Kopo S Seres Schneider Micro Meza T wido Matsushita FPOFPT LS Master k CPU Direct LS Master k CNet Com Para 19200 6 Even 1 Setting Back a esto Finish Cancel A Se Ll 6 After setting click ok to confirm and then click Next to continue 21 Software Parts Communication Parameter Baudrate Data Bit C 4600 C 38400 C 7Bits SBitz Stop Bit i 1Bit C Bits C 9600 115200 Parity check None C Odd f Even Mall Communication Time O MSEL W SendData YVirStation Retry times 3 cancel JL 7 Edit name author and remark as shown in the following below Project Author
82. ith PLC NW Simulate on line Connecting PC and PLC with cable and then simulating TP action in PC Hardware Parts 2 GENERAL SPECIFICATION TP460 series Item TP460 Input Voltage DC20 DC28V Current Consumption lt 180mA Electrical Allowable Momentary Less than 20ms Power cut Features ae Communication Port Support RS 232 RS 422 RS 485 Environment Interference Rejection Noise voltage 1000Vp p pulse duration lus 1 minute Surrounding Atmosphere free of corrosive gasses Protect Configuration Accord with IP65 Using Life 50000 hours upwards environmental temperature 25 C 24hours running Screen Display Area 240 128 Lighteness Contrast Adjustable by regulation resistance properties Language setting Chinese simplified traditional English Japanese Korean and others Character dimension Discretional font Discretional dimension Touch panel Matrix type touch Memorizer Cooling Manner Natural air cooling Configuratio External Dimensions mm 173 2 121 4 45 n Cutout Dimensions 164 112 For front panel mm Hardware Parts TP560 561 series Input Voltage DC20 DC28V Current lt 240mA lt 240mA lt 280mA Consumption Allowable Less than 20ms Momentary Electrical Features Power cut Voltage Endurance AC1000V 10mA 1 minute signal and time Insulated Resistance DC500V About 10MQ signal and time ee Support RS 232 RS 422 RS 485 or Download Port Support RS 232 Operat
83. ix AFKBIS AGVR I Font Containing font setting and word art setting 98 Software Parts Text Display Font Color Position Font Setting windows font Word art OF Cancel Apply Click to pop out Font dialog box as shown below Font style Times New Roman Shruti A C Tp SimHei Italic F Ls Y Sims Bold Small Fonts Bold Italic Spltaen O Symbol System Effects Strikeout Underline AaBb ty z Color Black S cript Westem Sample 2 Click sik to pop out Style dialog box 99 Software Parts Projectiort AAA gt o io a T Brink width j Coo a Fill Fill in with test s color R ARAN HY I Color as shown below Display Font Color Position Kind Color TEEF i ee ar olor NO SN Text Color More cancel tm Note Each component has its own color dialog box and there are some different of color parameters as the structure of components are not same We ll not introduce more about these in this manual you can set freely or refer to color setting of other components TR RRA AYR V Position It contains Position and Animal setting as shown below 100 Software Parts Text Display Fort Color Position Modify the position and Position Size size of the Text frame width Height ove the component simply and swift Vertical Lock caca
84. ject data acquisition source Cancel 180 Software Parts 3 Double click 0 DO or click Modify after selecting 0 DO can open its property dialog box in which data object can be change default object is FDO Trend Map Object Trend Map Pick Save Color Station Device Wirstanol O Station 1 Object Obiect D O Indirect Data Data word 4 In trend map tab page data number picking period data format map mode display mode and data range can be set as shown below Trend Map Object Trend Map Pick Save Color Data Display Count 10i Map Mode Pick Period 5 Sec f Fold Format C Dot C Dec Hex C Float Unsigned C Column Move Mode f Move Pen Move Paper Cancel 181 Software Parts 5 Set save area and then save the picking data to the assigned address Trend Map Object Trend Map Pick Save Color Object Obiect po O Indirect 6 Please refer to pervious chapters for setting method about Pick and Color 182 Software Parts 6 14 History Data Map History Data Map is similar with Real Time Trend As described in the above chapter Real Time Trend can only display the current data in the display area While History Data Map can save the current data in the display area in the format of history data then you can view and analyze them 1 Click LY and
85. l Project Screenz Fie Edit View Part Tool Window Help Ose e 2 Ak LA AA a ix SB mS o SOE En 100 ai r ix fp Project f screen Screen Window Cut Property I Click the screen or window needed delete H Click in the Operate Toolbar TouchWin Edit Tool Project Screen 5c reen2 File Edit View Part Window le O Gar bel les AB Y fas ES ELO A TTT ig R da 3 oy EI te mE oy a i rx gt Project H Screen HH Screenl Je 100 Screen 37 Software Parts 38 2 2 2 Downloading Data After editing connect 9 pin RS 232 port of PC and TP download 9 pin port with download cables Then confirm that TP has been powered with 24V DC Click a or from File gt Download Data to download data There will pop out a download window to Prompt download process Download Downloading Cancel If Time out check table please appear please re download Make sure that TP series touch screen can not be powered off while downloading screen data When the transmission finished a pop up dialog box will appear to show all the project screens have been transferred Download Download finish Cut off the power supp
86. lly used button values and ASCII values 1 0X31 6 0X36 ESC OXID 2 0X32 7 0X37 CLR OX7F 8 0X38 ENT OXD 4 0X34 9 0X39 5 0X35 O 0X30 127 Software Parts 5 17 Bar Graph Bar Graph can be used widely in Industrial control area It 1s more intuitionistic and convenient to show simulated data than Digital Display So 1t can be used for displaying analog parameters such as temperature pressure flux and so on 1 Add Bar part dl gt vertical and horizontal bar use the same icon as shown below MM Screen E Ed Pe From Property gt stick gt mode you can change it to horizontal bar graph 2 Open its property dialog box containing Object Stick Color Position as shown below Vertical Bar Object Stick Color Position Station Device WirstaWo Station 1 Object Obiect E O Indirect Data Data Word ll Lancel p 128 Software Parts 3 Her mainly describe the contents of stick tab page Vertical Bar Object stick Color Position Preview W Scale et aspect of Preview area scale line Upper Limit Lower Limit Man Scale Sepia Set limit range Data Format Dec C BottomLett Max 100 Mod i odify aspec blode I and mode Take an example to illustrate the setting of bar graph Supposing there is a simulate value input of pressure max data of A D is 4095 min data of A
87. ly of display Then pull out the cable TP SYS CABO and connect PLC and the PLC port in TP with communication cable Electrify PLC and the display then you can do data monitoring and other operations under normal communication Pay attention that incorrect communication parameters and connection can lead to failed communication and there will appear such words communicating which show that TP is communicating with PLC If TP and PLC can not communicate normally please check following items 1 PLC model in project should be selected according to the operating one 2 Communication Cable should be connected 3 Communication Cable should be connected in the right way 4 PLC Communication parameters should be set correctly 5 PLC and display should be electrified 6 If you still can not find the reason please contact with suppliers to get help Software Parts 3 INTRODUCING MENU This chapter introduces contents of menu and how to use them 3 1 File The function options in the pull down menu of File are used for managing and dealing with the whole project as shown below I TouchWin Edit Tool Project Screent wie Edit View Part Tool Window Help New Ctrl M P A AA ie E La E Open Chile Close Cho Es ls SES Save Chri s 100 HHH Save Os Chrl 4 BH Screent Download Ctrl D Run nLine B Ctrl B RunrflinefM Ctrl M ooo Setting Ctrl T ue ee wa eG GenSoftware bunches
88. mage the relevant object can be a certain bit of relay or register as the lamp 1s a double status parts 4 From the property page of Lamp you can modify Aspect and Use Text as shown below Lamp Object Lamp Twinkle Color Position Aspect Simulate the displays of tow status directly Change Aspect L JON AON a Change aspect of the lamp C OFF _User Defined le Visible Save Aspect M Use Tee The default setting of it has no tick After ticking it you can set font and align for the text There are Gallery 1 and Gallery 2 ON Lamp T_Circle_01 Lamp_T_Circle_02 Lamp T_Circle_O3 Lamp_T_Eolurna_ 02 Gallery1 has 46 kinds of z i n k multicolor pattern gt Q A Gallery 2 has 5 kinds of white and black pattern Lamp T_C_4 001 Lamp T_C_A 002 Lamp T_C_A 003 Lamp T_C_A4 004 i L 3 O a iii G Cancel 5 Next we introduce property page of Tinkle as shown below when select ON or OFF you can set 106 Software Parts speed of twinkle Twinkle can be set as alarm in the project application as 1t can abstract operators attention Cancel toy 6 Here we do not introduce the property pages of Color and Position you can refer to previous chapters for more information 107 Software Parts 5 5 Button 1 Click Button icon 2 Move cursor into the screen click your left key to finish placing th
89. n Print Window Width you don t want to print them spring object s value will be set 0 Spring Object Station Object M 0 Print Direction LefeRight Right Left 3 Add the print content you want in the print window s corresponding position and you will finish print window s setting the left map is a new screen window and the right one is the finished MN Print Window E Print Window 200 Software Parts 8 2 Connection of the printer Printer side TP series touch screen side 9 pin D Sub Female Parameter setting Baud Rate 9600 Parity Check Even Handshake has no limitation 201 Software Parts 9 SIMULATE FUNCTION Simulate Function is used for simulating actions and debugs of touch screen in the software without downloading program to TP With this function operator can do the project more convenience with less work 9 1 Simulate Offline Simulate offline function is used for simulating button actions in TouchWin software in PC without downloading data to touch screen also the data address read is local address Therefore you can browse the edit effect directly moreover you can modify the dissatisfied effect at will which can save time and make the operation more convenient Take the following as an example 1 Firstly edit a new screen and save it then place a button and a lamp on the screen with two object addresses as default value PSBO as shown
90. n and then release it until dragging the cursor to the finish point MM Screen Starting Point Border Point Finish Point 2 Editing arc 1 Drag the border Point to change the width and height of arc 2 Drag the starting point or finish point to change the length of arc 67 Software Parts 3 Property of Arc Thick integer between 0 255 the larger the value the thicker the line Line Port Fie Color Fosition Pattern Thick Cancel Apply Coordinates of points change the position and angle of starting point and finish point as shown below 68 Software Parts Line Port Fie Color Position Stark Io FEnd x E 270 Y 18 129 Cancel Conversion between arc and pie ticking pie can realize this conversion Line Fort Fie Color Fosition cancel tm After c1 c2 c3 c4 conversion it turns to pie as shown below 69 Software Parts MM Screen Fill this option can be only used when the graph is pie There are 256 kinds of color and 7 kinds of fill pattern Line Port Pie Fill Color Position cancel rob Fill Pattern 70 A None showing border without fill pattern B Solid filling graph with the selected color C Dot filling graph s inside with dot D Meek Filling the graph with color desalted Software Parts 71 Software Parts Line Fort Pie
91. n the touch screen to make relevant operation of time convenient Buzzer e Spring buzzer by controlling a certain coil or a bit component in a certain register This function can carry out alarm and prompt functions Refer to chapter 6 3 for particular usage 7 LCD Light Control E Similar with buzzer it is used for starting light to prompt user while using TP by controlling a certain coil or a bit component of a register Refer to chapter 6 4 for particular usage 13 Device It contains devices such as Instrument Valve Pipe Pump Auto Wind Motor and Retort which are widely used in industry automatization These device buttons can be used in graphics software directly therefore the workload can be reduced s Instrument It is point to dial instrument used for prompting and reading numerical value as voltage meter and ampere meter Refer to chapter 6 5 for particular usage Valve Y Its meaning and usage are similar with valves which used in normal industrial control area Refer to chapter 6 6 for particular usage z Pipe ES Show the change and flow direction of numerical value by liquid format Refer to chapter 6 7 for particular usage Pump 66 EN 22 It is similar with pump used in normal industrial control area Refer to chapter 6 8 for particular usage Auto Wind 2 gt It is similar with Auto Wind used in normal industrial control
92. nt ee reenter 138 AS INC TOM PP O A IA 139 9224 PURO A AS AAA AS 150 32 Discrete COMO MA a AA A aia 152 520 O AAA A 154 6 SPECIAL APART ISR GAY aida dies 156 ena a et eee ee reer 156 O mT A AE ANT AUNT O AONE err TE eT Te 157 O BUZZ AA aa 158 IN Be a 0 ne pera ern ae pe ne pe ee pa ee ere pee ae ney geet ee nee ee gene eae 160 A A II a hatin uuetees 161 OO VAY Sassi heeded este arent a keto E EEES 164 CIAO ds 172 OLO MOO at E A 174 A A A 176 622 InvertAlara Inormation cia ee 178 613 Real Time 0d aa 180 RA AAA AAA 183 OS E VONC 1010 y CODEC PRETO A RE REIT One a PRT RENE TE FREI Re T eee 187 6216 Display Real TIME Er o io aes 189 6 177 History EVA dis 192 AS A 195 TALARM WINDOW orei e a a a 197 SPRINT WAN DOW a aa 199 Sal Create A New WINdOW ismoil nna a a a a a a a R 199 O ls AMA A 201 FSIMULATE FUNCTION Sonar ia 202 A A nc OE 202 9 2 Stimulate OMS A Rese A eiak 204 DES CONO nt 207 OSPEC AET UNCTON Senna Cc 209 101 FP Series Internal Ob o o ia o tesly 209 10 2 Communication between TP and inverters ooccccnnnnnnnnnnnnnnnnnnnnnnnnnnnnonononnnnnnnonononononananaroncnoss 214 APPLICATIONS aoni E 221 VTP SERBEIESOPERATE METHODS 0 ii 222 1 1 TP series online COMMUNICATION uruissa iassa r a iaaa NE ei E E Ai 222 l 2 TP Series Touch Screen Password dt dicta 222 A nanana E EAEE E EE 225 PEC CONNECTING METHOD Sintesis 225 tae TT CT Co DOG AMA okie Ria ash hee RR a Ree Ahaha Rabies iaas 225 EZ VAI CSU DIS EE Ne SOSA ra 221 l2
93. of the machine freely by touch screen It is another way of human machine connection But when inputting data there must be a digital keyboard So Data Input must be used with keyboard 1 Place Data Input 231 gt on the screen if you want to modify several data you can put more components as shown below screen Sel Temperature Oooo E Pressure Oooo MPa 2 Property setting of Digital Input is similar with it of Digital Display The only difference is that there add on Input function Here we introduce Input tab page Open its property dialog box to do some setting Digital Input Set input limitation you can not input anything until Object Display Input Font Color Position open password Password Max bin Set range of Input the B Check me normal status has no setting W Popup KeyBoard Notify Set pop up keyboard without ticking you should add a a digital keyboard manually 2 Press BE to enter Simulate Offline status Supposing there is no password while operating click 120 Software Parts Digital Input and a pop up digital keyboard will appear as shown below Temperature Pressure 3 Press ENT to confirm input after typing data If you want to type data once more press CLR to clear the input box and if you want to exit without modification please press ESC 121 Software Pa
94. oil Reverse Call Copy Call Screen dump Set Data Copy Register User Input Open Window Close Window Down Scheme Up Scheme Data Block Transmit Anthmetic Cancel 140 Software Parts gt Modify After add a certain function successfully the Modify button will be sprung Click Modify to open its dialog box and do the relevant setting Button With Function Function Button Limit Color Position Function Pressing gt Reset Coil Reverse Coll Copy Coil Screen Jump Set Data Copy Register Delete User Input Open Window Close Window Down Scheme Up Scheme Data Block Transmit Arithmetic Password OF Cancel Apply gt Delete If you want to delete a certain function click it in the left box to turn over its color and then click Delete to finish this operation gt Move Down Up When there are more than two functions Move Down up can be sprung Click a certain function to turn over its color and then click Move Down Up can move this function If you want to move several steps click it continuously gt Password Password can affect the limitation of added function Click password to open the following window If you choose None all the user can carry out this function If you choose Normal Advance System user should input correct password and then can carry out this function 141 Software Parts Limit P
95. or more information about how to set COM port 208 Software Parts 10 SPECIAL FUNCTIONS This chapter mainly introduces the internal address of TP series touch screen and relevant operations between TP and inverts 10 1 TP Series Internal Object There are three kinds of TP series internal object PSB PSW and PFW PSB Bit PSW Word object need power PFW Word object which can maintenance without power 1 The following figure shows internal object s range of various types of inverter T Pe TP460 L TP560 561 TP760 T TPA60 A61 Object PSB256 PSB1023 PSW256 PSW409 PSW256 PSW1023 PFW256 PFW409 PFW PFW256 PFW1023 5 2 The range of PFW can be set by yourself the above figure describes the default value of system How to set PFW is shown below Click Setting from File menu as shown below I TouchWin Edit Tool Edit Tool Wind view Part Mer Ctrl h T Open Chrl 0 En Close Cil Save Chrl 5 D Save As Ctrl 4 j Download Ctrl D RuntnLine B Ctrl B Ron frrLinecrmM Ctrl M Setting CET Gensofkware Exit 209 Software Parts 2 From panel click set parameter can modify the number of PFW as shown below Project 5et Color Font Pr Fara Alteration Clack Mode TP760 1 Description 400234 256 colors Set parameter PFW Num 1024 visPSW Num 1024 PriPoy Hum Cache Mum Cancel 210
96. or the operators and make sure hand it to terminal user Notice Items O A O Please do not bind power line and communication cable together or let them too close keep at least 10 cm distances between them O Please do not install experimental module or refit wiring Otherwise it may cause malfunction error action damage or fire Please shut off the power when there is abnormal smell or voice with TP products The briefness call made by buzzer after electrifying is normal Please do not strike the touch panel with a hard or pointed object or press on the touch panel with too much force or with pen screw since these may damage the touch panel and cause malfunction Please tighten the screws while installation If these screws are not tightened firmly it may cause short circuit fire or malfunction Please transport store set up installed and maintain the product correctly otherwise it may damage the touch panel Please be sure the TP s rated voltage is within the designated range and that the power terminal lines are correctly attached Otherwise it may cause damage Please do not touch terminals when power on to avoid causing an electric shock Please do not open the cover board Please cut off all the power while installing or disassembling TP products otherwise it may cause misoperation and malfunction Please use TP series touch screen in the certain environmental conditions according to this man
97. ou want to unlock the object please right click on it and select Unlock that change from Lock Clike unlock and the you can release the object as shown below MM Screen ae eee Property Unlock A ee ee eee ew ee 2 ew Public Init ut TR O Copy oe ee ee ee ee et ee eee ee Delete Save 92 Software Parts 4 14 Moving Layer TP series touch screen has a layered function in one screen At present there are three layers namely top layer bottom layer and middle layer which are used for superposing or hiding the objects When there are more than two objects in one screen this function will be sprung As shown below firstly we put two rectangles in the screen and right click one rectangle then there will be added a function named Bottom Layer in the pop up menu correspondly there will be added a function named Top Layer in the pop up menu of the other rectangle MN Screen a ol Ed A A A a e Property LC AI Lack Bottom Layer E oe ee ee eee eee ee eee eee ee a a Public Linit DAA AAA AAA Cut La ee CIEN AAA AAA Cony E a a a a a a a e a a a ae e oi Delete Je o a Save Click Bottom Layer and move the small rectangle to the middle of the big one In default status the small rectangle will be coved by the big rectangle as they are in the same layer However you can find that the small rectangle still can be seen as it is set in the top layer as shown below
98. ox as shown below will appear Please refer to Down Recipe part for more information Function Down Scheme Object Groups Device Data Station Device PLC Port T WirStaNG O Station 1 Object Obiect E E l Indirect Scheme Data Object Obiect PF e 256 Data Grou 1 145 Software Parts gt Uprecipe Upload the device data PLC to the recipe data touch screen etc Click Modify and then its dialog box will appear Please refer to Up Recipe part for more information gt Data Block Transmit Transfer a data block starting from the appointed source ID register to the corresponding destination ID register You can set source address target address and register number as shown below Function Data Block Transmitted Object Source Address Station Device PLC Port WIrStaNO Station 1 Object Obiect ip O pD y Indirect Target Address Station Device y Wirstanol Station 1 Object Obiect p 0 p Hi Indirect Data Register 1 Cancel gt Arithmetic Do arithmetic with the set register s data then save the final value in the assigned Register The arithmetic object can be a constant as well as a variable 146 Software Parts Function Arithmetic Object Operand Station Device VWirStahlO Station 1 Object Obiect D O p Hi Indirect Data Data Word ll Lancel Function Arithmetic Object U
99. pe the device address is Device PLC Port D10 D15 This data section is VvirStaNo Station 1 used for saving recipe Object parameters The head address Obiect p y 10 of recipe database is set as Indirect PFW 300 as shown in the left rra nh Scheme Data Object Obiect PFW 300 Data Grou 1 caca too Down Scheme From Recipe we type 20 Object Scheme Button Color Position Count 20 in Count box canal doom 5 Add a Digital Input part to the screen and set PSW40 as its object 6 Set 1 as the value of PSW40 while system operating When we press Down recipe button recipe data will transfer the data with PFW300 PSW40 6 as their address and 6 continued register groups as their length to D10 D15 data section 157 Software Parts 5 22 Up Recipe The usage of Up Recipe is nearly as same as its of Down Recipe the only difference is that the direction of up recipe is reversed 1 Click ES to add an upload button to the screen MM Screen 2 Please refer to Down Recipe for the setting method of Object Up Scheme Object Scheme Button Color Position Device F Wirstalo O Station 1 Obiect lb O Indirect Scheme Data Object Obiect pry 256 Data GOO 1 138 Software Parts 5 23 Function Function button gathers the function of all buttons It can choose
100. perand Operate Kind fe Lett Operand f Use Constant 0 Dec C Use Variable Al Right Uperand f Use Constant 0 Dec C Use Variable E Cancel As shown above Click Modify after add Arithmetic to the left box then a pop up dialog box will appear The first graphics shows the tab page of Object which 1s used for assigning address saving final value the second graphics shows the tab page of Operand which is used for setting two operands When you select Use Constant please input relevant value type in its back box the default type is algorism When you select Use Variable please click _ to open its setting dialog box then set variable address in it as shown below 147 Software Parts Left Operate Object Device VWirStahlO O Station 1 Obiect b O Indirect 4 Button is mainly used for modifying text content button aspect and so on In its tab page there are passwords font align manner and aspect setting Please refer to previous chapters for more information Button With Function Function Button Limit Color Position Password Code C Hone Noma Advance Hide Buttori a a e aE Normal Change Aspect Y Use Text User Defined Content Fress Save Aspect Font Align Lett Align Top f Align Center f Align Middle Align Bight Align Bottom cancel Apo 5 Limit sup
101. ply a function of limitation After ticking Limit Button the function button will be available when the status of control coil is ON otherwise the button will be void As shown below 148 Software Parts Button With Function Function Button Limit Color Position Cancel app Click MO and then the following dialog box will appear in which you can set coil address as shown below Function Set Coil Object Station Device gt WirstaNG Cl Station 1 Object Obiect m 0 Indirect 6 Please refer to previous chapters for introduction about Color and Position 149 Software Parts 5 24 Function Field The usage of Function Field is similar with Function button but they are not the same The difference is on the function s trigger action Function button can set different operations to the four trigger actions But the function field has only one trigger action and must be sprung under logic conditions of system internal or pre setting instead of different button actions Besides function field is in hidden manner so it can not be seen in the screen a 1 Click Function Field gt and place it on the screen MM Screen E Ed Se bb AR we ee we REE Ee A Pe 2 Double click it s property dialog box then you can see the main difference between it and Function button is that it has a Mode tab 150 Software Par
102. r registration of a utility model or design are reserved Disclaim of Liability We have checked the contents of this manual for agreement with the hardware and software described Since deviations cannot be precluded entirely we cannot guarantee full agreement This manual is subject to change without notice 2007 11 Table of Contents PREFXACE oa E 1 SAET Y PRCAU TIONS cria alaba 3 HARDWARE PAR Scania ld 4 1 PRODUCT OVERVIEW sus due east teenie same seine aerate bau EE 5 AA O A NEN 6 E O AO A E In O f 2 GENERAL SPECIFICATION area a lead its 8 COMPONENT NAMES catarsis dei 12 FEXTERNACGDIMENSION S orian isa EE EE E aiii 16 gt INSTALLATION ME CHOD Seta id a 18 6 PORTINSTRUCTON 0 sees woe E esheets 19 7 REGULAR MAINTANCE AND CLEANINGooooooooocnncncnonnnnnnnnnnnnnnononnnonnnnnnnnnnnnnnonnnnnnnnnnnnanonnnnnncnnos 20 SOFTWARE PAR ES cua aaa 21 GRAPHICS SOFTWARE ai ee ie oe oes 22 Led Installing Th SOL WE 22 l 2 Components Of The Software Ord iii 24 RE TEIN GS TARTE chal ssn eine tage na eae A iaa 25 ZA Creatime A NE e o ala o e 25 222 EdtINE e e dad 30 2 2 1 Basic operation of editing screens and windows cccccccccncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnninoss 30 IA A tac sanweacesactteesseseraceseatteeeseseresens 38 3 INTRODUCING MENU ua iia iia a aida lia lid 39 A o scien Atco eased EE A deere tiene EEE E E TAE EE 39 E T Toe eon A Nee Nee ee ere E 51 SN LES PR RO OO O RL 52 A E 53 Ds e E E TON 59 G WACON orra
103. reen transfer cable OP SYS CABO Then connect TP series DOWNLOAD port and PLC communication port with PLC communication cable Check that if the PLC s communication parameters are correct Meanwhile electrfy PLC and TP TP series use DC 24V power the display will enter the status of run at once NOTE No matter whether PLC is in the status of running or programming TP series touch screen can work regularly 1 2 TP Series Touch Screen Password In order to improve the machine s safety the data on the touch screen must be modified only by the professional personnel So this demands that the touch screen must have the function of data protection The following we will introduce the touch screen s password setting 1 Firstly from File Setting set the system s parameter 2 There will pop out a system setting dialog box input the password and then click OK to confirm it The password has three grades Common Advanced and Systemic Common password can only carry out password protection function of normal grade Advanced grade password can carry out password protection function of high grade and common grade When input system password you can carry out all the password operations Project Set Color Font Project Para Alternation Clock Fanel Device Screen Start Screen Ho Password Adeance System 222 Application 3 Create a project screen set a Screen Jump button with which 1t
104. ress of the recipe database in personal computer as shown below Down 5cheme Object Scheme Button Color Position Device Data Station Device VWirstahlo Station 1 Object Obiect D O Indirect Scheme Data Object Obiect PFW 256 Data Eim Ea 1 Cancel A Recipe can be seen as a combination of several continued registers Its concrete meaning is defined by the user in their programs Usually recipe data are considered as parameters in user s program therefore 135 Software Parts different recipes correspond to different parameters and user can change recipes to come to the application of different technics The combined parameters length means the recipe length 3 Count in Recipe tab page stands for the total number of current recipes as shown below Down Scheme Object Scheme Button Color Position Count 20 cancel tm How can we differentiate recipe No in application Now we offer a internal register PSW40 as a skip of the recipe No When the value of PSW40 change the recipe will change Therefore we can change the value of PSW40 to finish all the recipe operations 4 Next we take an example to deeply understand the recipe operating 136 Software Parts Down Scheme Supposing what we operate is Object Scheme Button Color Position a technical recipe needed 6 dels Data parameters and 20 groups Station reci
105. rithmetic and so on m Function gt When you click this function button touch screen will carry out certain operation s One function button can spring many functions Refer to chapter 5 24 for particular usage a ELD y 7 Function Field It is similar with Function however their spring manner are different as Function Field can be sprung by button timer scan and so on Refer to chapter 5 25 for particular usage 11 Column Map It used for showing comparison of several data groups by column map containing discrete column map and continue column map z Discrete Column Map la It is mainly used for comparison of several data groups that addresses are discrete distributed There is no limitation of data numbers Refer to chapter 5 26 for particular usage z Continue Column Map lla It is mainly used for comparison of several data groups that addresses are continuous distributed Also there is no limitation of data numbers Refer to chapter 5 27 for particular usage 12 Basic Tool It contains Date Clock Buzzer and LCD light control which are used for some assistant functions such as prompt alarm and so on a Date 66 T 22 With this function you can display date on the touch screen So it may make relevant operational convenience and can prompt operators Clock 9 56 Software Parts It is similar with Date as it is used for display time o
106. rm release the event will disappear automatically Refer to chapter 6 16 for particular usage 7 Display History Event ES y With it user can record several alarm information which have been sprung It also can display the time of event sprung Refer to chapter 6 17 for particular usage 16 Sample Save Ps This function is used for picking data of a certain register with no limitation of number or time The picked data can be saved in a section registers of touch screen Refer to chapter 6 18 for particular usage Software Parts 3 5 Tool Tool Menu mainly contains several basic tools such as Line Rectangle Ellipse Fold Map and Option Note Arc Polygon Block Frame can be used from Draw toolbar 2 TouchWin Edit Tool Project Screent File Edit View Part Ma Window Help OE i Lime Rectangle s NO O Ellipse Fold EX Amm elo El 27 Project Screen Screen a Line 66 22 Describe line or bias both of which can be set line weight line length and color a Arc 66 Ss 22 Draw arc and use these arcs to form sector Also you can set their size line weight position color and filling pattern z Rectangle LI It is used for protracting rectangle or square which can be set line weight size color position and filling pattern z Ellipse O It is used for protracting ellipse It s setting 1s sim
107. rts 5 12 Text Input Just like Data Input when input text there should be a small text keyboard with it It s properties are as same as Text Display The following introduces how to input text 22 1 Place Text Input RE on the screen if you want to modify several characters you can put more Text Input components as shown below MM Screen Sele 2 Press BE to enter Simulate Offline If there is no password while operating a pop up keyboard for text input will appear after you click Digital Input The effect is shown below 3 Please refer to Digital Input and Text Display for particular introduction about its property 122 Software Parts 5 13 Set Data Set Data is used for evaluating register Although it is not used too often it is simple and swift in some places Normally we use relays to stand for two status and the relay is controlled by button and other components While sometimes we use data to control and Set Data can make this operation more simple 23 1 Add one Set Data component as shown below MM Screen a E 2 Open its property dialog box the first tab 1s Object which you modified object in it Set Data Object Operate Button Color Position Station Device WirstaWNiD Station 1 Object Obiect D O Indirect Data Data Word Cancel 123 Sof
108. s TouchWin Edit Tool Projec File Edit SEM Pare Tool windo Y Gee w Standard w Status h al wf Project w Paint 1 w Zoom g Pro w Status Change w Operate w Part a y Align w Panel Software Parts The Part menu is used for editing components in the screen It has the function with the Part Toolbar I TouchWin Edit Tool Project Screent File Edit View AER Tool Window Help 7 cS i Text Operate a E Display Input Keyboard Project Bar screer Dynamic Map Window Scheme Function Tool T Fr F FF F Device Inverter Alram Information Picture Display Sample Save 1 Text There are Text Dynamic Text and Variational Text supporting various language font size color and art effect ion a Text 66 A 22 Using it you can type common characters which are usually static ones Once you type them they can not be modified Refer to chapter 5 1 for particular usage EY z Dynamic Text 4A Display corresponding text to prompt user while data in the assigned register changing Dynamic text can support 16 contents of state corresponding values are 0 15 Refer to chapter 5 2 for particular usage EH 5 Variational Text 4 Allow user set data values and text prompt of the relevant value There is no restriction of data number Refer to chapter 5 2 for particular usage 2 Operate It contains Lamp Bit Button
109. s shown below Speed Register Device Virstanll O Station 1 Obiect lap 0 Indirect Data word 5 Please refer to preview chapters for relevant introduction about Color and Position 166 Software Parts 6 7 Pipe 1 Click and press left mouse button on the screen to add it as shown below Pe 2 Double click it on the screen to open its property window The first tab 1s Object Object Aspect Speed Color Position Station Device VirStahli Station 1 Object Obiect m O Indirect Cancel ple Object means the object flow in the pipe When its status is ON the liquid in the pipe will start to flow and when its status is OFF the liquid in the pipe will stop flowing 167 Software Parts 3 Open Aspect tab page the aspect of pipe and the direction of liquid can be changed as shown below Object Aspect Speed Color Position Aspect User Defined Save Aspect Direct f Order 0 Reverse Click button then the gallery of pipe will pop out There are 11 patterns offered As shown in the following figure there are some examples vi ir id AE AAA ath Pg ie aig aE GOUT TT GHH Pipe TR OUS_A Pipe TR 002 A Pipe T ROO A Pipe TE 004 A ed ES ee Fipe T R OOS A Pipe T R O06_A 4 Speed tab page is used to set flow speed for liquid its usage is similar with that of Valve Please
110. sequence of the samples Sample Save Object Pick Save Position Display Object Table Modify Delete Move Up Move D own OF Cancel Apply 3 In Pick tab page you can set total amount of data pick period manner of time and so on 195 Software Parts Sample Save Object Pick Save Position Count 10 Period Manner ymrhms hal Hone Control umrhmg This Regist was used to control z Pick caca emp 4 In Save tab page you can modify the samples save address which is internal address of touch panel as shown below Sample Save Object Pick Save Position Object Obiect jas cancel Apo 5 Please refer to relevant chapters for setting introduction about Position 196 Software Parts 7 ALARM WINDOW Alarm window is used to display alarm message when triggering It controls message display by a bit address of PLC 1 Create a new alarm window It 1s similar to creating a new window So it has two ways A OClick Alarm in the manage column with the left mouse button to make it in the highlight color 2 Click New icon in the Operate Toolbar I TouchWin Edit Tool Project Screent File Edit View Part Tool Window Help Deul amp amp nu aa nn wal ERE AAA Sais a Jeeves se A jet Gd 45 le MEA Sex e eel 4 Project A
111. spect tab page in which title name align manner number of rows total number of events and if show year can be set Histroy Event Column Ce First Title Spring Time C Second Align Left C Third width 118 Line Height Lines page Event Capacity i Show ear cancel 192 Software Parts 3 In Event tab page you can set spring address spring manner and alarm information and so on Histroy Event Aspect Event Save Font Color Position Add Modify Delete Order Object Alarm Message Trigger 1 MO Over wolt Secend cancel amy Click Add button can add event Click Modify button can modify the selected event as shown below Event Source Call Event Station Device PLC Port WirstaNG O Station O Object Spring Address Obiect 0 Indirect caca am 193 Software Parts Event Source Coil Event D escript Spring Event Spring Spring Manner AscendEdge C Descend Edge cancel amm 194 Software Parts 6 18 Sample Save This function is used for picking assigned registers every certain time and saving these data in a section of assigned address 1 Click and press left mouse button on the screen to add it as shown below MM Screen E Ed 2 Double click it to open its property dialog box The first tab is Object in which you can add modify delete and set
112. ster s Digital Input Input user s data into assigned register s Refer to chapter 5 11 for particular usage z Text Input AB Input text into assigned register s Refer to chapter 5 12 for particular usage 123 m Set Data 1 Similar with Function Button it can deal with X for the data in assigned register s Refer to chapter 5 14 for particular usage Software Parts 5 Keyboard It contains Digital keyboard ASC and User Input all of which are used for typing digital or text These input components support pop up keyboard without setting by user z Digital Keyboard Ed Place keyboard on the screen and support typing digital only Refer to chapter 5 15 for particular usage E Text Keyboard Place keyboard on the screen and support typing characters only Refer to chapter 5 15 for particular usage 1 User Input Type a certain value as a key in keyboard Refer to chapter 5 15 for particular usage 6 Bar It contains Vertical Bar and Horizontal Bar both of which are used for describing use s data with graphics m Vertical Bar i Show the value stored in certain registers and display real time changes of values Refer to chapter 5 18 for particular usage mM o z Horizontal Bar Have the similar usage with Vertical Bar the only difference is that it is level 7 Dynamic Map z Dynamic Map
113. t 15P D SUB Male 2 Communication Module FB DTBR DTBR E Communication Module FB DTBR DTBR E 232 Q 9P D SUB Male TP series touch screen side 9P D SUB Female 3 RS485 port Communication Module FB DTBR DTBR E RS485 port TP series touch screen side 9P D SUB Female 244 Appendix 1 11 Vigor VB series PLC TP Software Setting En Parameters Recommend Vigor VB Model COM Type RS232 Data Bits 7 Stop Bits l Parit poi Enea Baud Rate 19200 Station No l Device Address PLC Address Range Format Introduction Type 0777 Exterior input terminals 0777 Exterior output terminals 0 9255 Internal assistant terminals 0 999 Special assistant terminals TSTATUS 0 255 Timer status CSTATUS 0 255 D Dp Counter terminals TCOIL 0 255 CD CCOIL 0 255 D _ 0 199 D 16 bits counter 200 255 D 32 bits counter O O O O O O 0 9255 Data memory As 0 255 D Current value Coen OX Y M and S could be expanded as registers 245 TP VB CABO Wiring Diagram TP series touch screen side Vigor VB side 9P D SUB Female RS232 port 246 Appendix 1 12 Fuji SPB series TP Software Setting E Parameters Recommend Fuji SPB Model COM Type RS485 Data Bits 8 Stop Bits l Parit Baud Rate 19200 Station No l 247 Device Ad
114. t horizontal and vertical movement When ticking horizontal a change will appear as following below Line Color Position Position Size 38 Width aro El Height O Animal Alm Code0 Werical Lack Zoom Ratio caca a As shown in the above figure there add a button with the name Alm Code0 Click this button to open its dialog box 65 Software Parts Animal Object Format Station Device Virstahlo Station i Object Obiect Alm Code ol Indirect Data Data Byte Animal C Float C Unsigned Cancel Object option mainly used for Changing the offset of object coordinates unit pixel It contains the following setting options Device PLC port and Download port can be chose Station number of device Object Internal space of relevant device Data Word and Dword can be chose Note Indirect have the same usage as described in chapter 3 1 please refer to P46 Format option can help you select data format from decimal hex float and unsigned Lock ticking it the line will be fixed in the current position while other operations can be done 5 Click OK to save setting 66 Software Parts Examples of straight line various thickness MM Screen 1 Select the icon A from draw toolbar click at the starting point with pressing down the left mouse butto
115. ter my Network Places Files of type bmp Files bmp Cancel 2 The software only can support BMP format at present If you choose flower bmp double click its icon to open it then the map will be added to the current screen automatically with size and position can be dragged freely as shown below MS Screent 3 Double click the map to open its property window There are two options Map and Position Here we mainly introduce Map tab as shown below 85 Software Parts The default select is Normal if you Map Position want to tick Transparency please select Mask as well Step After ticking Mask click Changing to open its dialog from which you can choose maps Masked Changing map should be black and white map with the same size TEN E f Stretch C Copp Please refer to the following example for better understanding W Screent As shown above mapl is the original map Next we deal with this map Map2 is a masked map with same size and it should be black and white Map3 is the final map after transparence worked 86 Software Parts 4 9 Changing Dimension The following describes how to change the size of graph and object which show how to extend or shrink There are two ways can finish this operation TR RRA YR Choose one that you want to extend or shrink sim AHI On the pes down left mouse button and drag the
116. ts Function Held Mode Function Position C Coil Spring 0 TimelSec C Continue C First Scan After Down C First Scan After Power cancel Act Mode you can only choose one spring action gt Start Screen When the screen in which the function field is invoked the function field s ever has function will be carried out gt Coil spring When the appoint coil jump from 0 tol the function field s existing function will be carried out gt Time sec When the screen in which the function field is invoked the function field s existing function will be carried out These functions will be carried again in a certain time which can be set gt Continue When the screen in which the function field is invoked 1t will carry out the existing function in continually gt First scan after down The function of Function Field will be operated once after downloading the project gt First scan after power The functions in Function Field will be operated once after every starting 3 The option tab s function is the same to the function button Just add them to the existing function Please refer to previous chapters for concrete information 151 Software Parts 5 25 Discrete Column Map Discrete column graph s horizon axis takes discrete register as fold line object and presents each register s value with graph 1 Click Ma and place it on the screen MM Screen1 Sc
117. ts Illustrating how to use TP with practical cases to make user understand deeply gt Appendix Parts Introducing the connection methods between TP and other popular types of PLC Qualified Personnel This manual is intent for the following personnel 7 Terminal Users m Debug Engineers m Technique Supporters Please read and understand the safety precautions very carefully before operating or debugging Validity of the Manual This manual may only be used for TP series touch screen and its graphic software made by Xinje Electronic Documents In addition to our written manuals we offer electronic documentations of our products by the following ways 7 User CD There are software user manual and application tip of relevant products Preface Website Please visit Ying s Electronic Co Ltd at www yingselectric com to obtain all variable electronic documents Welcome to contact us if you have any problem Tel 0577 62791815 62766815 Fax 0577 62791825 Address Room 602 No 292 North Liuqing Road Liushi town Yueqing City Zhejiang Province 325604 China Safety Precautions SAFTY PRECAUTIONS Essential introduction about product operation Please read this manual very carefully before operation and please operate correctly while paying close attention to all the safety points The following contents only used for TP series touch screen Please keep this manual properly place 1t where can be read easy f
118. tting effect Here you can choose center color and brink color freely Also you can change the center position default position is the centre of a circle as well as the ratios of X Y Line Fort Fie Fill Color Position Center Color LJ Se A Brink Color bb Hatch X 30 ry A T 30 Linear de pao A D O gui Y 0 v coed Frame Color There are 256 kinds of color can be selected and the default color is black Line Port Pie Fil Color Position Eind Color en a a a i More 74 Software Parts Position set the position and size of a certain object accurately by modifying its coordinates width and height Line Port Pie Fil Color Position Position Size ES width Y Animal Horizontal Vertical Lock Zoom Ratio cancel Apo Example of a pie i Software Parts 4 3 Rectangle 1 Click CI in the draw toolbar Press down the left mouse button at the starting point and drag the cursor to the finish point then release the left mouse button to finish painting Screen ig a Ed As shown above there are 8 reference points on the border of rectangle With these points you can change the length width and size of the rectangle 2 Setting line weight integer between 0 255 the larger the value the thicker the line Rectangle Line Color Fill Position Pattern Thick OF Lan
119. tware Parts 3 The second tab 1s Operate Set Data Object Operate Button Color Position Function C C C A Constant e E Operand 0 Format f Dec C Hes C Eloat C Unsigned Add operand to the current object Subtract operand from the current object Multiply operand to the current object Divide operand to the current set the current value as operand 4 Please refer to previous chapters for particular introduction about other tab pages 124 Software Parts 5 14 Digital Keyboard 1 In the process of input and modifying data keyboard plays an important role in linking people and machine As it is simple and convenient the current operator is more likely to use it 2 You can refer to others to place the small digital keyboard 3 Small digital keyboard should be used with data input In the Data Input we have introduced before we adopt the keyboard s use mode as the default state this 1s pop out mode But we can modify data input and character input property at the same time Such as the following map Digital Input ld Cancel the pop up digital keyboard When typing Object Display Input Font Color Position data you should add a Password digital keyboard None Normal Advance System manually has Min Check Check ee O Popup KeyBoard Notify an aunado 4 As shown below add ud to the screen there sho
120. ty dialog box containing Object Range Manner Scale Color and Position You can set address of the retort in the Object tab page as shown below Retort Object Flange manner Scale Color Position Station Device WirstaWo Station 1 Object Obiect E O Indirect Data Data Word ll Cancel only 3 In Range tab page you can set max and min values which can be concrete value as well as values assigned by registers with ticking variable The alarm is used for starting alarm function when the value 176 over the alarm value set Retort Object Range manner Scale Color Position Max 100 Min 0 Wariable Variable W Alarm W Check Max W Check Min Max 100 Min T Wariable Wariable C Alam Fast f Alarm Slow caca 20 There are four maps in Manner tab page Retort_T 001 A Retort_T 002 A Retort T 0053 A Retort T 004 A 5 Scale tab page in which you can set scale values is shown below Main Scale d Slave 5cale a cancel Software Parts 177 Software Parts 6 12 Invert Alarm Information Inverter alarm information is used for alarming it will spring alarm under certain conditions This function can display multi characters which can be used as multi item alarm 1 Click and press left mouse button to add it to the screen as shown below MS Screent E E
121. ty setting dialog box click Operate and type the window s ID which you want to operate If you want to operate the current window just choose current window Then the window ID color will turn to gray In the Act column you could set act mode open close and hold You could also set the window hide or show Window Button Operate Button Color Position Curent Window window ID 1 Function Type Open Window C Hide e Show Position EN Lancel 2 In the display column you can modify the text content which will display on the button If you want to close a window by this button you can change it to close 134 Software Parts 5 21 Down Recipe Recipe function is very important in dealing with data in the industrial area especially for craftwork recipe There are recipe upload and recipe download upload means save the device data in locale to recipe database while download means transfer the data in recipe database to device database in locale We describe how to use recipe download in the following 1 Firstly click E to add recipe download function button on the screen MM Screen Sele Pe 2 Double click to open its property dialog box There are Device Data and Recipe Data in Object tab page Device Data is used for typing head address of the data invoked in work locale and Recipe Data is used for saving head add
122. ual it may cause accident Please do not use the products in the environment with high frequency radiation high magnetic field or other interferences Hardware Parts HARDWARE PARTS Features Specifications Dimensions and Application notes of TP series touch screen 1 Product Overview 2 General Specifications 3 Parts Description 4 External Dimension 5 Installing Method 6 Port Instruction 7 Daily Maintenance and Cleaning Hardware Parts 1 PRODUCT OVERVIEW Summary of products TP series touch screen is a device connecting with PLC inverter and other control devices to carry out digital display monitor switch control and other operations With visual menu good compatibility high performance price ratio they have been the optimal choice of middle and small size control system According to product s sizes operation modes there are models in the following table 4 7 Inch Blue white LCD TP460 L Blue white LCD TP560 L TP560 G 5 7 Inch 7 0 Inch 256 Color TP760 T Black white LCD TPA60 L 10 4 Inch 256 Color TPA60 T TPA61 T 256 Color TP560 T TP561 T All the models working voltage in the above table is DC24V unless otherwise special noted Hardware Parts 1 1 Features Thinget TP series touch screen contain products with various dimensions and functions as shown below Moreover user friendly graphic editor supporting simulate on line off line and configuration function will
123. uction Type 0 377 Exterior input terminals 0 377 Exterior output terminals 0 2047 Internal assistant terminals 0 1023 Special assistant terminals 0 255 Timer Status e 0 255 D Dp Couter terminals 0 9999 Do D 0 7999 D Data register SD 0 255 D Z 0 15 D T 0 255 D Timer C16 0 199 D 16 bits counter C32 200 255 D 32 bits counter O O O O O 250 Appendix TP EC20 CABO Wiring Diagram RS232 communication TP series touch screen side EC20 side 9P D SUB Female COMO COM RS485 communication TP series touch screen side EC20 side 9P D SUB Female COMO COM F Bl Eds 4 Al RS485 251 1 15 OEMax NX7 series TP Software Setting Parameters Recommend PLC NX7 Model COM Type RS232 RS485 Data Bits 8 Stop Bits l Parit y None Check Baud Rate 9600 Station No 1 Device Address PLC Address Range Format Introduction Type R 0 127 L 0 63 M 0 127 K 0 127 F 0 15 TC 0 255 W 0 6000 SV 0 255 O O O O J o o g 0 255 J I O SR 0 511 252 Appendix TP NX7 CABO Wiring Diagram TP series touch screen side NX7 side 232 port 9P D SUB Female 9P D SUB E 5 GND 5 GND 253 254 MEMO
124. uld only one digital input component can be sprung for the current screen then the digital keyboard will connect to the input part automatically Please press ENT to finish inputting after typing data Thus set one digital keyboard can be used for all the digital input components to type data 125 Software Parts 5 Open property tab page of keyboard there are Color and Position can be set From Color you can change the keyboard color which contains Fore Color Black Color and Frame Color Mini Key Board Color Position Kind Color Back Col 8 Pa alar NM ME Frame Color More Cancel 5 15 ASC II Keyboard Similar with Digital Keyboard ASC II keyboard should be used with Text Input You could refer to Digital Keyboard for usage Click ASCII Keyboard icon 4 to add it to the screen as shown below 126 Software Parts 5 16 User Input All the buttons of Digital Input and Text Input are fit together with User Input and each button value correspond to one ASCII value therefore the data inputted can be divided With this function button you 22 can make a keyboard by yourself Click t and place it on the screen as shown below E Screent E E e Open its property window User Input Uperate Button Color Position Input ASCII Code Ox The following shows relationship between norma
125. wnload PSW60 Times of successful communication COM 1 Download Times of failed communication COM 1 Download PSW62 ee Times of overtime communication COM 1 Download PSW63 are Times of communication data turn wrong PSW64 COM 1 Download Device version PSW65 COM 1 Download Device Type Times of successful communication of PSW61 PSW70 COM 2 PLC Times of failed communication of COM PSW71 2 PLC Times of overtime communication of PSW72 COM 2 PLC Times of error data communication of PSW73 COM 2 PLC PSW74 Device version of COM 2 PLC PSW75 Device Type of COM 2 PLC Note PSW60 PSW65 shows communication condition when use COM 1 Download to connect slave LC mJ 2 NO Software Parts 5 ign as O T a ac oy z Object Name PFW1 PFW2 PFW4 PFW6 PFW8 PFW10 PFW11 PFW20 PFW21 PFW22 PFW23 PFW24 PFW25 PFW30 PFW31 PFW32 PFW33 PFW34 PFW35 Start Screen No In AAA Isaias Men COM 1 Download 4800 9600 19200 38400 115200 data bit COM 1 Download COM 1 Download COM1 Download FS COM 1 PLC COM 2 PLC 4800 9600 19200 38400 115200 data Bit COM 2 PLC 0 1 bit 1 1 5 bits 2 2 bits COM 2 PLC 0 None 1 Odd 2 Even COM 2 PLC COM 2 PLC Unit ms send delayed data 213 Software Parts 10 2 Communication between TP and inverters TP series touch screen add a new function to communicate with
126. x value Set the min range of alarm it will twinkle to alarm when data exceed Check Value its min value Cancel 118 Software Parts 5 10 Text Display Text display is used to display the register data in the form of text in the touch screen So we can display text more easily We can see its intuitionistic advantage when save different files or do the relevant operations according to different names Its properties are as same as Digital Display Difference between Text Display and Digital Display Text Display can show data in the form of Text while Digital Display shows data directly Here we illustrate this in the following figure 1 Click Text Display part EE and place it on the screen as shown below Belk 2 Open its property dialog box Display Text Object Display Font Color Position Station Device VWirStahlO Station 1 Object Obiect E O Indirect Set length of display Text Data Register 1 Cancel Note One word is composed by two bytes one character s size is one byte and one register s size is one word Thus you can set the register s number namely the length to change the content of displayed characters As shown above the register s number is 1 as default setting then it will display two characters 119 Software Parts 5 11 Set Data Data input is used to modify the working parameters
127. xk rra 9 Project 7 EN irent rado Alari Print E g you can type Front Screen instead JOES of Screenl 34 Software Parts 3 The modification of window property is similar with screen property as shown below Window 1D width us Revisable Name Window Height 120 Message E g you can type Prompt 2 2 1 3 Cut Copy of screens or windows There are two ways to do cut copy for the created screens or windows I Right click a special screen window in the project manager and then choose cut copy in the pull down menu x Project El Screen T window 1 Alarm 1 Print Delete Property II Right click Screen Window choose Paste in the pull down menu x Project ag gc s Insert T alarm 35 Software Parts Click the screen or window in the project manager then click cb Also from Edit gt Cut or Edit gt Copy this operation can be realized 2 TouchWin Edit Tool Project Screent File Edit View Part Tool Window Help osa CIA sx NOOCC OH li 2 100 MM Screen Project Right click Screen Window and then choose Paste in the pull down menu x Project 1 gc Insert a Alarm Print 2 2 1 4 Delete screens or windows Also there are two ways I Right click the screen or window needed delete II Choose Delete in the pull down menu 36 Software Parts I TouchWin Edit Too
128. y after you let the Fold without the tick the fill mode of polygon is default 79 Software Parts Polygon Line Color Polygon Fill Position M pgz P1 0 13 COIE P2 84 0 Revolve Pa 34 64 P4 155 394 P5 114 110 Pe 14 110 caret ao 5 Revolve Click Revolve in Polygon option to open the following dialog box type value positive value means counterclockwise rotation negative value means clockwise rotation in Angle box and then click OK to confirm 6 Fill It can be used when the graphic is close type such as polygon Please refer to relevant chapter of painting pie for setting method 80 Software Parts Line Color Polygon Fill Position Graphs filled color is what user chose Color Ls carcel amm 7 Position Please refer to previous chapters Examples of fold Examples of polygon Et la Bem Ba Bae Pa da Bas aa k BET VLT SLT LT s 1 ot a A Ed LT ENEE 81 Software Parts 4 6 Polygon Block 1 Click gt in the toolbar and press down left mouse button at the starting point of polygon to confirm acme 2 Let the left key go to confirm the second acme If you increase the acme number please repeat doing this 3 Double click at the end acme and you will finish drawing a polygon block 4 Drag eight reference points to change size width and height of the block MM Screen
Download Pdf Manuals
Related Search
Related Contents
Samsung MM-G25 User Manual Philips DCM105 User's Manual Graco Inc. GMAX 258731 User's Manual PDFファイル Directions for installation and maintenance LG WM1377HW Energy Guide USER'S MANUAL - by Loci Forensics BV La gare de Hombourg, une réaffectation réussie La ligne 38, un Viking VK20 and VK30 - User Manual Copyright © All rights reserved.