1. RTU SMTP EtherGate SNMP Interface IEEE 802 3u 1995 and IEEE 802 3x 1997 ISO IEC 8802 31993 Ethernet 10BASE T 100BASE TX connectors RJ 45 cabling Category 5 or 6 unshielded twisted pair max length 100 meters 328 feet Isolation Transformer isolated to 1500 volts RMS Data rates 10 100 Mbps Duplex full half 100BASE FX fibre connectors SC cabling 62 5 125 or 50 125 micrometer multimode fibre optic Max length 2000 m 6562 ft full duplex 400 m 1312 ft half duplex Data rates 100 Mbps Software integration Integrate within PowerLogic facility level or enterprise wide power and energy management systems Real time data and data logs stored onboard can be automatically retrieved on a scheduled basis for analysis at the system level Compatible with StruxureWare Power Monitoring software and PowerLogic ION Setup Modbus compatibility and register based logged data supports integration and data access by building automation SCADA and other third party systems Add value to your SCADA system by ntegrating high accuracy readings using the IEC 61850 protocol Special features Flash based firmware allows upgrades via communications without removing the meter from the site Simply download the latest firmware from www schneider electric com com Safety construction IEC 1010 1 EN61010 1 CSA C22 2 No 1010 1 UL 61010B 1 Electromagnetic Immunity IEEE C 37 90 1 1989 EN50082 2 Dielectric withstand 2500 VAC RMS at 6
2. and one auxiliary Three current phase inputs are provided as well as two auxiliary inputs for neutral and ground current measurement Specifications Input s Voltage inputs Nominal full scale 347 direct V ac line to neutral 600 V ac direct line to line rms 2500 V ac 60 Hz for 1 minute 0 05 VA per phase at 5 A standard 0 015 VA per phase at 1 A optional Standard 85 to 240 V ac 10 47 to 63 Hz 110 to 300 V dc 10 burden typical 15 VA max 35 VA Optional low voltage dc power supply rated inputs 20 to 60 V dc 10 burden typical 12 VA max 18 VA Current probe options Meter supplied with current probe inputs configured for use with standard 0 1 V ac current probes Probes sold separately Accuracy depends on probe specs Meter supplied with current probe inputs and 3 calibrated Universal Technic 10A clamp on CTs meeting IEC 61036 accuracy Front panel amp remote display Use for display and configuration purposes Both the integrated LCD display and colour touchscreen remote display allow quick Secure access to basic meter configuration screens for numeric and time stamped values frequency spectrum harmonics phasor display trend logs and name plate data Each display is capable of automatically scrolling through display screens that present at a glance volts amps power energy and demand values screens are easily customised to suit user requirements The alohanumeric text d
3. optional 5 mMmB 10 mB 5 mB 10 MB Min max historical waveform logging OE e Timestamp resolution in seconds 0 001 0 001 Historical trend information via front panel display Oo e GPS time synchronization O m Communications and I O RS 252 485 RS 485 Eirene Opie J m Epon DNP 30 via seal modern Ethernet MR pons w w Modbus RTU slavelmastor Modbus Tcp w J w osso o ra EtherGate ModemGate Meerman weones w 3 Setpoints alarming and control Setpoints number minimum response time 65 cycle 65 cycle Math logic trig log linearization formulas O a Call out on single amp multi condition alarms Ta E Please contact your local sales representative for ordering information Visit www schneider electric com for more information on other PowerLogic products applications and system solutions Schneider Electric 35 Rue Joseph Monier CS 30323 92506 Rueil Malmaison Cedex Tel 33 0 1 41 29 70 00 www schneider electric com PLSED106016EN 02 2012 ART 821269 2012 Schneider Electric All rights reserved As standards specifications and designs develop over time always ask for confirmation of the information given in this publication ION ION Enterprise Modbus and PowerLogic are either trademarks or registered trademarks of Schneider Electric All other trademarks are property of their respective owners Publishing Schneider Electric Production Schneider Electric
4. tariff period Inputs and outputs All models provide digital inouts as well as Form C mechanical relays and Form A solid state relays digital outputs Optional digital and analog I O is also available Digital output relays respond to internal alarms external digital input status changes or commands over communications Use digital inputs to trigger alarms or logging synchronize to a demand pulse or control conditional energy accumulation Input output Specifications Electro 3 Form C relays 250 V ac 30 V dc max voltage 380 V ac 125 mechanical relays R1 R3 V dc Turn on time 15 ms max Turn off time 5 Form C contacts ms max Update rate 1 2 cycle or 1 second NO K NC Solid state relays 4 Form A digital Maximum voltage 30 V dc maximum current outputs D1 D4 80 mA isolation optical update rate 1 2 cycle or 1 second Analog option 4 inputs Alt to Al4 Signal type dc current range O to 20 mA scalable 4 to 20 or O to 1 mA accuracy 0 3 of full scale update rate 1 second 4 outputs AO1 to Signal type dc current range 0 to 20 mA A04 scalable 4 to 20 or 1 to 1 mA scalable O to 1 update rate cycle or 1 second 8 inputs S1 S8 Self excited using SCOM output dry contact sensing no external voltage required Min pulse width 1 ms max pulse rate 20 pulses sec Timing resolution 1 ms update rate 2 cycle after timing resolution isolation 300 V peak max rated volt
5. 0 Hz for 60 s Installation category III 2000m above sea level Electromagnetic compatibility IEC 61000 4 2 EN61000 4 2 IEC 8012 IEC 61000 4 3 EN61000 4 3 IEC 801 3 Radiated EM Field Immunity IEC 61000 4 4 EN61000 4 4 IEC 801 4 Electric Fast Transient IEC 61000 4 5 EN61000 4 5 IEC 801 5 Surge Immunity IEC 61000 4 6 EN61000 4 6 IEC 801 6 Conducted Immunity IEC 61000 3 2 EN61000 3 2 IEC 61000 3 3 EN61000 3 3 FCC Part 15 Subpart B Class A Digital Device EN55011 CISPR 11 EN55022 CISPR 22 EN61000 6 4 EN5008 1 2 Environmental conditions Operating temperature 20 C to 70 C 4 F to 158 F no formation of ice Low Voltage DC Power Supply 20 C to 50 C 4 F 122 F Storage 40 C to 85 C 40 F to 185 F Humidity 5 to 95 non condensing Features Metering Power quality sag swell harmonics monitoring O fm EET capa Harmonics individual even odd up to d PSL Harmonics magnitude phase and inter harmonics pF 0th LASS A symmetrical components zero positive negative DIGITAL Pareado 6UL us Power ION7550 ION7650 LISTED 20 J 2 N gt gt 7e GS 2 o ISO 9001 QMI SAI Global File 002188 Recording compliant wih IEC 61000 430 Class Ae 2 w Eoss YS ENSOI60 compliance checking o o Transient detection microseconds 20 17 fomersoe wen Disturbance direcion detection Logging and recording Memory standard
6. Gain energy insight and control with PowerLogic PowerLogic ION7550 ION7650 power and energy meters Schneider Electric L L A A Financial management including accounting and billing BA gg Facility and energy management gA Operations management includnig engineering planning and maintenance N L mm Q Power generation transmission and distribution ates Service entrances and onsite generation Gas Power mitigation and main power distribution equipment gags PDUs and data servers Integrated network comprising corporate intranet Internet serial dialup or wireless connections Processes lines machines or equipment E Typical uses within a PowerLogic power and energy management system Features High visibility multilingual IEC IEEE configurable display Choice of displays including a large backlit LCD integral display or a separately mounted color touchscreen display The displays provide multiple simultaneous real time and timestamped historical parameters as well as graphical trends and histograms User configurable IEC or IEEE notations 12 24 hour clock support in multiple date time formats English French and Spanish languages High accuracy standards Meets stringent IEC and ANSI measurement accuracy standards such as IEC 62053 22 Class 0 25 ANSI C12 20 0 2 Class 10 amp 20 Digital fault recording Simultaneously capture voltage and current
7. PMC Printing Imprimerie du Pont de Claix made in France ee Printed on recycled paper
8. age 120 V dc external excitation 8 inputs option Self excited internal 30 V dc supply dry DI1 DI8 contact sensing or with external excitation 1 3 to 0 1 mm2 16 to 28 AWG min pulse width 20 ms max pulse rate 25 pulses per second update rate 1 2 cycle after timing resolution EtherGate and ModemGate The meters can provide gateway functionality depending on communication options EtherGate provides access from an Ethernet network Modbus TCP protocol to devices connected to the meter s serial ports Modbus protocol ModemGate provides access from the telephone network to devices connected to the meter s serial ports EtherGate ModemGate Telephone Ethernet Serial line Serial Internet connectivity Exchange information using XML to integrate with custom reporting spreadsheets databases and other applications WebMeter an on board web server provides access to real time values and PQ data through any web enabled device and supports basic meter configuration tasks MeterM il automatically emails user configured high priority alarm notifications or scheduled system status update messages to anyone anywhere within the facility or around the world IEC 61850 protocol the meter becomes an IEC 61850 server with client reporting and control functionality FTP the meter acts as an FIP server for IEC 61850 configuration and file support and COMTRADE format waveform records General spe
9. alance Frequency present min max 0 005 Hz Power real kW reactive kvar apparent kVA per phase total Power demand kW kvar kVA IEC 62053 22 class 0 25 IEC 62053 22 class 0 258 1 Refer to User s Manual for valid measurement ranges 2 Refer to Compliance section Not applicable for NICT meters contact factory for measurement specifications Energy real kWh reactive kvarh apparent kVAh rec del Power Factor at unity PF Power quality Power quality compliance monitoring for international quality of supply standards plus specific data for localized and custom compliance agreements and network connection requirements o Harmonics all models individual harmonics up to the 63 K factor and total harmonics distortion THD o Sag Swell all models voltage waveforms for sags and swells i e ITI CBEMA Type 2 and Type 3 disturbances report on each disturbance s magnitude and duration Detect sub disturbances during a sag swell event o Disturbance direction detection all models analyse disturbance information to determine the direction of the disturbance relative to the meter Results are provided in the event log along with timestamp and the level of certainty of disturbance direction o EN50160 ION7650 with EN50160 ordering option only monitor compliance with EN50160 parameters o IEC 61000 4 30 Class A ed 2 ION7650 only monitor compliance of relevant parameters such as powe
10. alysis results are captured in the event log along with a timestamp and confidence level indicating level of certainty Trending and forecasting Forecast values such as demand to better control demand charges and billing rates View results via the meter s web pages Analyse trends to support proactive maintenance schedules Transformer line loss compensation Automatically measure compensate and correct for transformer or line losses when meter is physically separated from the point of billing or change of ownership Mounting options Multiple mounting options to suite your installation from traditional panel door mounting a meter with integrated display to mounting a TRAN unit inside the panel and utilizing the remote display in the panel door Intelligent metering and control devices Used at key distribution points and sensitive loads the Schneider Electric PowerLogic ION7550 and ION7650 meters offer unmatched functionality including advanced power quality analysis coupled with revenue accuracy multiple communications options web compatibility and control capabilities Integrate these meters with our StruxureWare Power Monitoring software or share operations data with existing SCADA systems through multiple communication channels and protocols Typical applications For infrastructure industrials and buildings O Energy savings o Measure efficiency reveal opportunities and verify savings O Reduce peak demand surch
11. arges o Reduce power factor penalties O Strengthen rate negotiation with energy suppliers O Enable participation in load curtailment programs e g demand response O Identify billing discrepancies O Leverage existing infrastructure capacity and avoid over building O Support proactive maintenance to prolong asset life O Energy availability and reliability O Validate that power quality complies with the energy contract O Verify the reliable operation of equipment O Improve response to power quality related problems For electric utilities O Energy availability and reliability O Improve T amp D network reliability O Enhance substation automation to reduce field service time o Maximise the use of existing infrastructure o Revenue metering and power quality O Install new high accuracy metering at all interchange points O Improve or verify metering accuracy at existing interchange points O Verify compliance with new power quality standards O Analyse and isolate the source of power quality problems 192 m mm 7 56 las Meter installation showing rear mounting clips 7 8 22mm ae M EEEE Js 4 41 163 on Remote display installation in panel door Sc hneide a i PowerLogic colour touchscreen remote display Installation Circuit and control power connections include 4 wire Wye 3 wire Wye 3 wire Delta Direct Delta and single phase systems Voltage inputs include 3 phase one reference neutral
12. channels for sub cycle disturbance transients as well as multi cycle sags swells and outages 1024 samples cycle waveform recording 20 17 us transient capture 50 60 Hz Power quality analysis and compliance monitoring A choice of THD metering individual current and voltage harmonics readings waveform capture EN50160 and IEC 61000 4 30 class A ed 2 ION7650 only power quality compliance evaluation and voltage and current disturbance sag swell detection COMTRADE format waveform records are now available only for meters with the Ethernet port option Complete communications Gateway functionality simplifies communications architecture and reduces leased line or connection costs Concurrent independent ports communicate with protocols such as ION DNP 3 0 IEC 61850 Modbus RTU Modbus TCP Modbus Master Ethernet port allows the following concurrent connections 24 Modbus 8 generic ION DNP Modbus 4 IEC 61850 dedicated client 1 FTP and 1 SNMP Dial out capability when memory is near full Data push capability through SMTP email Patented ION technology Provides a modular flexible architecture that offers extensive user programmability Uniquely addresses complex monitoring and control applications Adapts to changing needs avoiding obsolescence Disturbance direction detection Determine the location of a disturbance more quickly and accurately by determining the direction of the disturbance relative to the meter An
13. cifications Description Specifications Communications Multiple communication ports that operate simultaneously allow the meters to be used as part of a power and energy management system and to interface with other automation systems Upload waveforms alarms billing data and more to software for viewing and analysis Specifications Serial RS 232 RS 485 port COM 1 Protocols include ION Modbus RTU Modbus Master DNP 3 0 GPS EtherGate ModemGate Data rates 300 to 115 200 bps Duplex Full RS 232 Half RS 485 Max length RS 232 15 2 m 50 ft RS 485 1219 m 4000 ft total for entire bus Serial RS 485 port Protocols include ION Modbus RTU Modbus Master DNP 3 0 COM 2 GPS EtherGate ModemGate Max length 1219 m 4000 ft total for entire bus Data rates 300 to 115 200 bps Duplex Half Internal modem COM Data rates 300 bps to 56 kbps V 3 4 V 32 bis V 32 V 22 bis 3 V 22 A B V 23 V 21 Bell 212A Bell 103 Supports automatic data rate detection RJ 11 interface Approvals FCC P68 USA Industry Canada CS 03 Also approved for use in Austria Belgium Denmark Finland France Germany Greece Iceland Ireland Italy Luxembourg Netherlands Norway Portugal Spain Sweden Switzerland UK ANSI C12 18 type II Protocols include ION DNP 3 0 Modbus RTU optical port COM 4 Data rates 1200 to 19 200 bps Duplex half Ethernet port Protocols TCP IP DNP TCP ION IEC 61850 Modbus TCP Modbus
14. isplays are capable of supporting international labels such as OBIS and VDEW Multilingual operation can be user configured for English French Spanish or Russian Set parameter measurements via front panel to comply with regional preferences Modbus Master feature allows display of real time parameters of any downstream modbus devices 1 Russian only available on the integrated display Ft EBEEB HZ a z Era bd o Phasor display remote touchscreen li Harmonics 1007 2005 22 20 13 14 HARMONICS THD 400 THO Even 20 0 THD Odd 20 9 Harmonic current display Trend display remote touchscreen WAN AAV MANAN HTT i i DA i Vy 1 IIET Hit HA i F Ci Example screen from PowerLogic ION Enterprise software showing continuous wide area monitoring data capture and reporting for power quality and reliability conditions Power and energy measurements High accuracy 4 quadrant energy metering in accordance with IEC 62053 22 class 0 2S for both 3 and 2 element systems Real bidirectional reactive and apparent values Fully programmable integrating period 1 5 10 15 30 60 minutes or other Supports block rolling block and predicted demand calculations such as kW kvar and kVA demand min max Volts and Amps demand min max Cumulative demand Demand on any instantaneous measurement Parameter Accuracy 1 reading Voltage line line line neutral per phase min max unb
15. nsive data logging configuration Data is prioritized and stored onboard in nonvolatile memory to eliminate data gaps in the event of outages or server downtime Retrieved data is stored in an ODBC compliant database when using PowerLogic ION Enterprise Trending and forecasting capabilities track specified quantities over time and forecast the value of future quantities View trending and forecasting data through the meter s web pages Logging capacity is available in 5 MB or 10 MB configurations Default depth and interval of logging is set at the factory and depends upon onboard memory size O Revenue log configured for use with UTS MV 90 billing software Logs kWh delivered interval kWh received interval kvarh delivered interval KVARh received interval values O Historic logs record standard power system quantities such as phase current ohase voltage and power factor o Report Generator log configured to provide power system data for PowerLogic ION Enterprise software O Event log O Trend display logs Multiple tariffs and time of use TOU calculations 20 year calendar with automatic leap year and seasonal time adjustments and clock synchronization over communications channel or GPS TOU is configured four seasons five daily profiles per season four tariff periods per daily profile Automatic mid season rate change Active reactive and apparent energy and demand automatic recording of maximum peak demand during each
16. r frequency magnitude of supply voltage flicker supply voltage sags and swells transients and voltage interruptions Create compliance reports using PowerLogic ION Enterprise software O Transient ION7650 only voltage waveforms of transient activity i e ITI CBEMA Type 1 disturbances o COMTRADE waveform format records are available directly from the meter via the FTP server meters with Ethernet port option only Vil ab Last 24 Hours amp Forecast Minimum Average Maximum Forecast Minimum Forecast Average Forecast Maximum cts TVW YY 207 95 207 90 207 85 YIL ab 207 80 207 75 207 70 NVA NANA SOE 12 00 16 00 18 00 21 00 00 00 03 00 06 00 09 00 12 00 Hours Trending and forecasting as viewed from PowerLogic ION7650 web page lION7550 ION7650 500 500 Events events events events Data 1 5 years 3 1 1x2 2 9 years years years A 16 parameters recorded every 15 minutes B 30 waveforms on 6 channels at the maximum sampling rate C 30 waveforms on 12 channels with any selectable format for example 6 channels are 512 samples per cycle for 4 cycles and 6 channels are 32 samples per cycle for 54 cycles _ I O CARD scom S8 S7 S6 S5 S4 S3 S2 S1 All Al2 AB Al4 AO1 A02 A03 A04 Top view of optional 1 0 card installed showing connectors for digital inputs analog inputs and analog outputs Data and event logging Ships with a comprehe