Home
skc-600dc sliding gate opener owner`s manual
Contents
1. Limit switch wires and motor wires have been connected before delivery JX5 OP 5 Open N C CO COM Limit switch CL Close N C D D Motor Fig 16 8 Operation Manual operation see Fig 12 If the gate has to be operated manually due to a power loss or malfunction of the automated system use the release key as follow e Fit the supplied key in the hole Turn the key counter clockwise to disengage the clutch Open and close the gate manually e After power is restored use the manual release key to tighten the clutch by turning the key clockwise and resume normal operation Fig 9 Safety Auto Reverse Obstruction Sensor The Obstruction Sensor continuously monitors the gate movement for any obstructions If any obstructions are detected when the gate is closing the gate will stop and reverse back to the open position If any obstructions are detected when opening the gate will stop The factory setting is set at MAXIMUM sensitivity You may need to increase or decrease depending on the weight and the condition of your gate Adjustment of the Auto Reverse Function e Tuning the auto reverse safety function To adjust the opening force rotate the Open Force VR2 knob See Fig 15 with a screwdriver The resistance may be increased or decreased by rotating clockwise or counterclockwise To adjust the closing force rotate the Close Force VR3 knob See Fig 15
2. ADDITIONAL FEATURES e Keypad single button interface e Infrared safety beam interface e Supports up to 25 RF remotes 2 included e User programmable and user erasable remote codes For your safety the SKC 600DC will stop and RF hopping code technology prevents thieves from guessing your remote code Auto close feature is available for this opener reverse if is encounters an obstruction on closing and stop when it encounters an obstruction on opening as required by UL 325 safety standards Self locking at any position Battery Backup for loss of power conditions Manual key release design for emergency purposes e Supports Keypad interface and Magnetic Loop Detectors simultaneously 3 Specifications Diagram 1 Specifications Power Supply 110V AC Maximum Number of Remote Controls 100 2 Included Maximum Gate Weight 300 KG Maximum Gate Width 8m Duty Cycle S3 40 Output Torque Max 7NM Gate Speed 16m min Limit Switch Magnetic Limit Switch Normally Closed NC Remote Control Range gt 30m Remote Control Frequency 433 92 Mhz Noise lt 60db Environmental Temperature 10 C 40 C Battery 12V 7Ah Emergency release key in case of power failure 4 Necessary Tools and Equipment The following tools may be necessary to install the SKC 600DC Gate opener You will need standard and Philips screw drivers an electric drill wire cutters an
3. 12VDC POSITIVE FOR PHOTOEYE HEREKE N MOSFET BUZZER U POWER INPUT MOTOR n MOTOR 2 i wW BLACK MOSFET O BRO ae BRIDGE DC POWER INPUT 1 Joey RECTIFIER Fig 11 OPERATOR OPERATOR SIDE The control box should be equipped with a single phase breaker 10A Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again See Fig 3 and wiring notes for control board Wire your AC line into the AC IN terminal on JX 1 Verify that all electrical connections are waterproof by installing electrical outlets into exterior grade boxes with waterproof covers Make sure that whenever an electrical connecter enters or exits a box it is sealed If using solar verify that all connections are waterproof and install solar power terminals into and terminals in JX 5 RF Remote Control Button 1 Button 2 2 G 6 Button 4 amp O Button 3 Fig 12 The remote control works in a single channel mode It has four buttons The function of button 1 button 2 and button 3 are the same With each press of the remote control button which has been programmed the gate will open stop close or stop cycle Button 4 is available to set pedestrian mode Note if you cancelled the pedestrian mode the function of button 4 is the same as the other three buttons Warning Notify the users that the gate is never to be operated unless it is in full vi
4. Se Dani TE DES en mr a cee 5 z a LEDI e DEU een inn RO A e e U LED2 48 DEED vern rk TAWE i el lele m En SO gee 5 LEARN A Si F Ee _ j Ta ra ae 8r Ogg e e w oa Su T zee nD qe L UR2 e CT el om li l e m RHS TM a 498994 5 A OO m B O Oe UR3 te eo Ce Dm je mn 28 e L di om LI Fig 15 Control Board Scheme Diagram 3 Terminal blocks Terminal block Mark Description AC IN Battery charge power supply input i e transformer JX1 output 16 V AC 30 VA A No connection 12 0 5 Power supply output DC12V GND DC5V JX2 RF No connection DI Keypad signal input 12 0 Power supply output DC12V GND JX3 IR Infrared photocell input BI Open signal input JX4 ZZ Alarm lamp DC12V Max 10W OP CO CL Limit switch open limit common close limit JX5 D D Motor 1 lt is used to adjust the auto close time and pedestrian mode SW 2 No connection ERE 3 No connection 4 It is used for open and close limit adjustments LED1 Battery charge indicator light LED2 Status indicator light Others LEARN Learn button VR2 Set the open force VR3 Set the close force JX2 JX3 DI gt BI _ Open signal 12 Keypad signal o input N O o input N O 12 5 12 RF 0 _ Infrared IR input N C
5. at all times Check inside cover for insects Check and tighten anchors bolts The operator can be powered by battery in case of power failure A fully charged standard battery still can provide enough power for operating 10 cycles after power disruption Normally max number of cycles per day is less than 20 Please switch off the battery if no power is available for more than 5 days remove the plastic cover set the power switch which on the top of the operator to OFF position i e press the O to down position failure to comply with the above instructions may damage the battery or shorten its life e We recommend you put some grease in the keyhole to avoid rusting also regularly grease the wheels and axles if the gate was jammed or cannot be moved smoothly Occasionally inspect the chain to ensure that it is well lubricated and oil the chain as necessary Table 3 Troubleshooting Trouble Possible causes Solutions Motor only runs in one direction The wire connector terminal block has become loose Check wire connector terminal block make sure it is plugged in terminal block 10 X8 The limit switch wire connector terminal block has become loose Check limit switch wire connector terminal block make sure it is plugged in terminal block 9 X9 Check the limit switch mode The electric component on the control board such as Q2 Q91 or Q92 may be damaged Replace the electric component Q
6. cannot be accessed by reaching through the gate e To Avoid electric shock unplug unit before opening case e Make sure the battery inside the operator is charged fully before using e Before installation the clutch should be unlocked e The auto reverse function must be checked during installation to ensure that the gate can auto reverse in the event of obstruction and it should be inspected regularly e The automatic gate opener must be grounded e Install the gate opener on the inside of the property DO NOT install it on the outside of the property where the public has access to it e Additional safety equipment such as photoelectric sensors safety edges roller guards and warning signs must be installed to prevent injury e Inthe event of power failure an emergency release key allows you to operate the gate manually e Please erase and reset the code after installing the opener e The gate opener should be installed by a qualified technician otherwise serious personal injury or property damage may occur For service call an experienced technician Do not in any way modify the components of the automated system otherwise serious personal injury or property damage may occur We do not accept responsibility for damage or injury resulting from installing of this operator 2 Features Class l A vehicular gate opener or system intended solely for use in a single family home or an associated garage or parking area
7. either written or verbal is expressed or implied Gatekeeper Ltd and it s dealers or distributors specifically disclaims any and all implied warranties of merchantability or fitness for a particular purpose lt is the purchaser s sole and exclusive responsibility to determine whether or not the equipment will be suitable for a particular purpose In no event shall Gatekeeper Ltd and it s dealers or distributors be held liable for direct indirect incidental special or consequential damages or loss of profits whether based on contract tort or any other legal theory during the course of the warranty or at any time thereafter The installer purchaser and or end user do agree to assume all responsibility for all liability in use of this product releasing Gatekeeper Ltd and it s dealers or distributors of all liability For service under this warranty please contact your dealer All parts accessories service and support for Gatekeeper products is supplied through our network of dealers Dealer information can be obtained at www gatekeeperltd com dealers Gatekeeper Ltd P O Box 752 Laceys Spring AL 35754 info gatekeeperltd com For updated versions of the manual see http www gatekeeperltd com For Additional Remotes Infrared Photo Cells or Parts please contact your dealer To locate a dealer please visit us at www gatekeeperltd com dealers
8. with a screwdriver The resistance may be increased or decreased by rotating clockwise or counterclockwise By turning the overload variable resistors you can adjust how much force it will take to cause the gate to stop and auto reverse when closing or stop if opening Note 1 With each press of the button the gate will open stop if moving or close NOTE 1 If the auto reverse direction is wrong exchange the wires D and D or exchange the two magnet brackets position 2 When the gate meets the correct place in both opened and closed positions it will auto stop and switch off automatically otherwise exchange the two magnet brackets position WARNING Do not attempt to tune the gate by placing your hand arm or other body part in the path of the gate as serious injury could result Damage to the gate opener motors may also occur by placing a heavy immovable object in the path during the testing phase If the setting is still too high place a light object in the path e g a chair or trash can which can be pushed out of the way without causing damage to gate motors Note This auto reverse function should be regularly inspected and adjusted if necessary Once the tuning is complete you may replace the cover 9 Maintenance amp Troubleshooting Every six months check the following items for proper operation of the unit Check the chain lubricant and add 1 grease regularly Lubricate shafts and sprockets Keep opener clean
9. 2 Q91 or Q92 BTA16 600 or replace the board Gate auto closes immediately after opening The auto close time is too short Reset the auto close time See Set auto close function section When you use button 4 of remote control to open the gate pedestrian mode gate travels too short The width of pedestrian mode is too narrow Reset the width of pedestrian mode See Set width of pedestrian mode section When you use button 4 of remote control to open the gate pedestrian mode but the gate will auto close immediately The auto close time of pedestrian mode is too short Reset the auto close time of pedestrian See Set auto close function of pedestrian mode section The gate will not open or close The limit switch wire connector terminal block becomes loose Check the limit switch mode see table 1 Dip switch Connecting wires or terminal blocks are too loose Check the connecting wires and terminal blocks The electric component on the control board such as Q2 Q91 or Q92 may be damaged Replace the electric component Q2 Q91 or Q92 BTA16 600 or replace the board Power switch is OFF Make sure power switch is ON Remote control does not work The indicator light of remote control does not light Check the batteries on your remote control Remote control is not suitable for receiver After making sure the codes are correct erase remote controls an
10. GatekeeperLtd www gatekeeperltd com Hin EANNA Tir k pe Ta Yard SKC 600DC SLIDING GATE OPENER OWNER S MANUAL 2005 Gatekeeper Ltd P O Box 752 Laceys Spring AL 35754 http www gatekeeperltd com OUTLINE 1 Safety Precautions 2 Features 3 Specifications 4 Necessary Tools 5 Site Preparation 6 Mechanical Installation 7 Electrical Installation 8 Operation 9 Maintenance amp Troubleshooting 10 Warranty 2005 Gatekeeper Ltd P O Box 752 Laceys Spring AL 35754 http www gatekeeperltd com 1 Safety Precautions Installing the SKC 600DC Gate Opener requires installation of standard 110V electrical wiring This work should only be performed by a trained technician Miswiring could cause personal injury or DEATH To prevent the risk of electrocution be sure to turn off all power to the SKC 600DC until installation is complete e Fingers hands and loose clothing may be dragged into chain sprockets please keep hands fingers and loose clothing away from chain and rotating sprockets e The Gate may move at any time ensure all persons are clear of the gate when It is moving to avoid the risk of injury Do not touch the gate while it is in operation Do not attempt to go through the gate while it is still in motion This operator is intended for vehicular use only e Do not allow children or pets near your gate Keep the remote controls away from children Place controls where they
11. LATION of this magnetic switch is the NUMBER 1 cause of trouble with this opener 10 15mm NS en gt Magnetic limit Magnet Gate operator MAE VRE ISI Spring washer E Gate r a Fig 8 7 Electrical Installation Connecting the battery see Fig 10 Connect the red battery lead to BAT terminal of control board and black battery lead to BAT Battery RED WIRE TO POSITIVE BLACK WIRE TO POSITIVE Fig 10 Connecting the motor see Fig 11 Connect motor wires to M and M of terminal block JX4 NOTE all the wires above have been connected before delivery NOTE The operator is only designed to work for less than 20 minutes at a time Work duty S3 40 If it runs continually for an extended period of time the MOSFET will burn out because of the high temperature NOT USED NOT USED NOT USED NOT USED LO Ki 5 N TRANSFORMER N O INPUT FOR PUSH BUTTON AND KEYPAD 5 ien BLUE BLUE RED RED 12 NOT USED oo NOT USED D 9 OPEN common lO N C PHOTOEYE INPUT en En i
12. d then re program the codes in the device See Adding extra remote controls learning section Broken receive board Replace receive board When you open the gate by using the remote control gate will stop in mid travel or reverse before reaching the fully limit position The Force Adj VR1 is adjusted too small Check the Force Adj VR1 Adjust VR1 to increase force Gate is obstructed Remove the obstruction The remote control operating distance is too short Signals are shielded by the gate Link a new antenna 1 1 2m BVR 0 75mm see parts list to the old antenna Then fix the antenna on the wall vertically make sure the total height from the top of antenna to the ground is approx 1 5m 10 Warranty Gatekeeper Ltd Limited Warranty Gatekeeper Ltd Warrants the SKC 600DC Sliding Gate Opener to be free of defects in materials and workmanship for a period of 1 year from the date of purchase subject to certain limitations This warranty shall not apply in the following circumstances misuse vandalism accident neglect unauthorized repair or modification acts of God lightning flood insect damage etc power surge corrosive environments incorrect installation or application damage to mechanism due to wrong type of gate incorrect weight gate not operating freely or not on level ground etc The warranty set forth here shall be entirely exclusive and no other warranty
13. d a wire stripper a socket set and possibly access to a welder 5 Site Preparation Before you begin the opener installation the gate should be mounted and moving freely there should be little resistance in the movement of the gate The gate and post must be suitable for being automated Check that the structure is sufficiently strong and rigid and that its dimensions and weights conform to those listed in the specifications table of this document Make sure that the gate is plumb and level The fence posts must be mounted in concrete The SKC 600DC is powered by 110V 60Hz AC power therefore if you have not already done so wire a waterproof outlet near the gate following proper safety standards for your area If you are not experienced with this type of wiring or if your area requires it hire a professional electrician to perform this as well as wire in the SKC 600DC in the electrical section The SKC 600DC requires at least a 10A service Make sure your electrician takes into account the voltage drop involved in running many feet of wire to your installation location If an insufficient gauge of wire is used there will be insufficient power at the site to operate the opener If you plan to use solar panels to power your gate verify that you have sufficient solar power to charge the battery and provide power for the number of openings and closings you plan to need Different areas of the planet receive varying amounts of sunlight and that amo
14. d beam is broken during closing the gates will reverse and open immediately During opening the beeper will ring Infrared photocells come in active and passive varieties Active photocells require power on both sides of the driveway whereas passive photocells employ a reflector plate so that power is only required on one side of the driveway Most photocells will provide DC power input wires and and 2 normally closed switch wires To install the photocell attach the DC power wire to terminal 3 12V and the common ground or DC wire to 5 COM on jack JX3 Remove the short circuit wire between 4 and 5 i e IR and COM connecting the photocell as shown in Fig 14 Attach the normally closed wire to IR and the other common normally closed wire to 5 COM These signal wires are not polarized so they can be interchanged without issue Consult your device manufacturer s documentation for details See diagram 14 The infrared device can be obtained through your dealer To find a dealer go to www gatekeeperltd com dealers PHOTOCELL JX3 3 12V 5 COM 4 IR kl 12V GND 12V GND COM Signal Photocell transmitter Photocell receiver Fig 14 JX1 JX2 JX3 JX4 JX5 Hi r i rm RE 0 0 0 0 09000 0 0 0 0 0 0 0 0 00000 ACN p o 2 5 RF BI COM IR i3 z Z w W E CB 4 k
15. d switches of SW DIP switch to OFF position up immediately At this point the auto close function of pedestrian mode has been set Note the new width of pedestrian mode has been re programmed and replaces the original width that you have set in Set width of pedestrian mode section If you open the gate by pressing button 4 the gate will stop at the new expected position that you have set After the time passes that you have set the gate will close automatically Cancel width auto close function of pedestrian mode Cancel width and auto close function of pedestrian mode factory preset Move the first and the second switches of SW DIP switch to ON position down press button 4 to open the gate see Verify open direction section Wait for more than 15 sec then press the same button to stop the gate and wait until the gate closes automatically 45 sec Stop the gate by pressing button 4 or the gate will stop at its closed position automatically if the limit switch is reached Then move the first and the second switches of SW DIP switch to OFF position up immediately Thus the width and auto close function of pedestrian mode has been cancelled Cancel width of pedestrian mode keep auto close function of pedestrian mode Move the first and the second switches of SW DIP switch to ON position down press button 4 to open the gate see Verify open direction section Wait for more than 15 sec then press the same button
16. ew Procedure to add an additional remote control learning process Press the LEARN button with a screwdriver see Fig 13 the LED2 will flash and turn off then press the remote control button which you want to use the LED2 will flash about 2 seconds and then turn off This indicates that the learning process is complete Up to 100 remote controls may be used Additional RF Remote controls can be obtained through your dealer To find a dealer go to www gatekeeperltd com dealers Erase remote controls To erase existing remote controls press and hold the LEARN button until the LED2 turns off Sliding Gate Operator fas OPEN CLOSE FORCE FORCE LEDI LED2 SW LEARN gt 9 W8 O Fig 13 Verify open direction If the gate does not move in the desired direction then you will need to reverse the motor operating direction You can do this by exchanging wires D and D or by exchanging the two magnet bracket positions and then insert the wire connector terminal block Set auto close function This feature can be selected to make the gate stay open for some time before it automatically closes The auto close time can be adjusted to between 0 and 44 seconds Move the first and the second switches of SW DIP switch to ON position down see Fig 13 press remote control button button 1 button 2 or button 3 that has been program
17. he first and the second switches of SW DIP switch to ON position down press button 4 to open the gate see Verify open direction section Wait until the gate travels the distance that you desire the distance range is 0 3m 2 5m or wait for 3 10 sec it is regarded as the width of pedestrian mode Then press the same button to stop the gate wait for some time 1 44sec Close the gate by pressing the same button Press the same button again to stop the gate or the gate will stop at its closed position automatically if the limit switch is reached Then move the first and the second switches of SW DIP switch to OFF position up immediately Thus the width of pedestrian mode has been set If you open the gate by pressing button 4 the gate will stop at the expected position that you have set Set auto close function of pedestrian mode Move the first and the second switches of SW DIP switch to ON position down press button 4 to open the gate see Verify open direction section Wait until the gate travels the distance that you desire about 3 10 sec Then press the same button to stop the gate wait for the time you desire 1 44 sec this period of time is known as auto close time of pedestrian mode Close the gate by pressing the same button Press the same button again to stop the gate or the gate will stop at its closed position automatically if the limit switch is reached Then remember to move the first and the secon
18. ian mode has been cancelled Note the new width of pedestrian mode has been re programmed in the device and replaced the original width If you open the gate with button 4 the gate will stop at the expected position that you have set but the gate will not close automatically External Interfaces Keypad Button Switch The SKC 600DC is equipped with an interface for an external switch or keypad The interface type is a NO Normally Open momentary switch to ground To activate the opener the keypad or other device must short the 0 and DI terminal momentarily on Box JX2 This type of switch is very common To install the device attach one lead of your keypad to the DI terminal and the other to the 0 terminal The keypad will function in single channel mode just like the RF remote If the gate is closed then activating the keypad will open the gate If the gate is open then activating the keypad will close the gate If the gate is moving then activating the keypad will stop the gate If your keypad requires DC power then you can use the 12 or 5 terminals and the 0 terminal for ground as required by your device See diagram 3 Consult your device manufacturer s documentation for details The keypad device can be obtained through your dealer To find a dealer go to www gatekeeperltd com dealers Loop detector A magnetic loop detector detects vehicles that are within proximity to the gate A magnetic loop detect
19. justment The SKC 600DC Chain Driven Gate Opener will handle gate weighing up to 300Kg 6611b and up to 8m 26ft if the proper installation procedures have been followed The SKC 600DC chain driven gate operator operates by forcing a straight piece of chain through its chain box This length of chain is extended between two chain brackets located at opposite ends of the gate The motor rotates the worm and worm gear which drive the chain and pushes the bracket fixed to the gate thus moving the gate The entire configuration is shown in the diagram above Gate preparation Be sure the gate is properly installed and slides smoothly before installing the SKC 600DC sliding gate operator The gate must be plumb level and move freely Conduit In order to protect the wires use PVC conduit for wires Conduit must be preset into the concrete when it is poured Wires within the conduit shall be located or protected so that no damage can result from contact with any rough or sharp part Concrete Pad The base unit of the gate opener requires a concrete pad in order to maintain proper stability The concrete pad should be approximately 24 600mm x 12 300mm x 18 460mm deep in order to provide for adequate operation The pad should be 3 70mm above finish grade Be sure to locate the pad so that it will not interfere with the gate In locations where ground freeze is possible extend the pad below the frost line Once the gate is
20. med to open the gate see Verify open direction section Stop the gate at any position by pressing the same button wait for some period of time that you would like the gate to remain open prior to auto closing 1 44sec this period of time is known as auto close time Close the gate by pressing the same button Press the button again to stop the gate or the gate will stop at its closed position automatically if the limit switch is reached After this setup is complete then move the first and the second switches of SW DIP switch to OFF position up immediately At this point the auto close function has been set Cancel auto close function Move the first and the second switches of SW DIP switch to ON position down press remote control button button 1 button 2 or button 3 that has been programmed to open the gate see Verify open direction section Stop the gate at any position by pressing the same button wait until the gate closes automatically 45 sec Press the same button again to stop the gate or the gate will stop at its closed position automatically if the limit switch is reached Then remember to move the first and the second switches of SW DIP switch to OFF position up immediately Thus the auto close function has been cancelled Set width auto close function of pedestrian mode Pedestrian mode can be used to open gate about 0 3 2 5 meters for people to pass through Set width of pedestrian mode Move t
21. mounted adequately electrical power is available and the concrete pad is poured you are ready to proceed Anchors You can use the anchors that are provided with the opener 3 anchor bolts 4 anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors 1 4 x 4 Operator Base Mount the gate opener base to the concrete pad The distance between the gate and the base should be no more than 2 1 2 64mm Verify that the opener is leveled properly Gate operator BER Socket thread cap screw o Chain box Mia ee eee dels Operator base Nut and washer Anchor bolt 60 10mm Anchor Conduit Wire Concrete pad 95 Fig 3 Mounting size Chain Box Make sure the ends of the guide chain are out of the chain holes on both sides of the chain box Remove the cover and insert the manual release key and turn counter clockwise to disengage the clutch Remove the elastic band from the shaft and line up the key on the shaft with the sprocket at the chain box Insert the sprocket from the chain box into the operator shaft Place the operator on top of the base and use four socket head cap screws to mount the chain box in to the base Opener Using bolts M8x20 and washers 8 mount the operator to the base Before tighteni
22. ng the bolts insert the operator cover make sure there is no more than 2mm between the cover and the chain box Check the operator and make sure it is lined up with the gate Fig 4 Chain Brackets Use the appropriate bolts to attach the chain bracket to the frame of the gate If the gate is of square frame style use the square bolts shown Align the chain bolt with chain hole on the chain box Gate Square frame Plain washer 6 Square bolt 2Z Spring washer 6 l L bracket Nut M6 H im Plain washer 8 C Master link Chain bolt Nut M8 Spring washer 8 Fig 5 If the gate is of round frame style use the round bolts shown Gate a Plain washer 6 Round frame j Round bolt Spring washer 6 L bracket EE Nut M6 Plain washer 8 3 Master link Chain bolt Nut M8 Spring washer 8 Fig 6 Chain see Fig 7 Close the gate and attach a chain bolt to the piece of chain that comes with the chain box using enclosure master links Tighten the chain bolt to the bracket with washers and nuts Pull the chain through the chain wheel box to the other chain bracket at
23. or can be used to open the gate when a car pulls up either from the inside or the outside depending on which side of the gate you install it A magnetic loop is usually buried under the ground and the wires run to the gate opener control board Magnetic loops usually require DC power using the and DC terminals They provide a normally open momentary switch interface to the control board and its ground or common interface Wire the magnetic loop s DC wire to the 12 terminal on block JX3 wire the power common or ground to COM Wire the magnetic loop s normally open trigger wire to terminal BI and the normally open ground or common to COM both on block JX3 The terminal BI is a free open terminal This means that it will only open the gate if the gate is already opening it will have no effect if the gate is closing it will override and open the gate but triggering the terminal Bl will never close the gate Consult your device manufacturer s documentation for details See Figure 4 for a diagram of external interface connections The Loop Detector device can be obtained through your dealer To find a dealer go to www gatekeeperltd com dealers Safe guard Infrared device or Photocell It is recommended that the installer purchase and install infrared photocells for additional safety Photocells work by inhibiting the movement of the gate if the beam is broken Infrared safety devices may be required by law in some areas If the infrare
24. the opposite end of the gate Connect the other end of the chain and the chain bolt and then tighten the chain bolt to the chain bracket Thread up the chain by adjusting the chain bolt Cut the chain to length if necessary Make sure that the chain is perfectly aligned with the chain holes on the chain box Tighten the chain by tightening the chain bolts at either end See illustration below Chain bolt Master link Magnets for limit switch Install the magnet as shown in Fig 8 The magnet and limit switch are used to control the position of the gate When the magnet is installed release the gear clutch and push the sliding gate manually to pre determine the position Fit the magnet bracket to the gate and then tighten the gear clutch The lower bracket is for open position and higher bracket is for close position Finally adjust the magnet to the proper position by moving the gate with the motor The magnet should be 10 15mm 1 inch away from the magnetic limit switch If it is too far away the switch will fail to work Moving the gate electrically adjust the position of the magnet until the positions of the opening and closing meet the requirements Important Note There are two reed switches inside the magnetic limit switch one is upper and the other is lower Please note the two magnet brackets fixed plate are different one is higher and the other is lower Verify and if necessary exchange the two bracket positions MIS INSTAL
25. to stop the gate wait the number of seconds that you desire 1 44sec then close the gate by pressing the same button Press the same button again to stop the gate or the gate will stop at its closed position automatically if the limit switch is reached Then move the first and the second switches of SW DIP switch to OFF position up immediately Thus the width of pedestrian mode has been cancelled the auto close function of pedestrian mode has been reserved Note the new auto close time of pedestrian mode has been re programmed in the device and replaces the original auto close time of pedestrian mode which you have set in Set auto close function of pedestrian mode section Keep width of pedestrian mode cancel auto close function of pedestrian mode Move the first and the second switches of SW DIP switch to ON position down press button 4 to open the gate see Verify open direction section Wait until the gate travels the distance that you desire the distance range is 0 3m 2 5m or wait for 3 10 sec Then press the same button to stop the gate wait until the gate close automatically 45 sec Stop the gate by pressing the same button or the gate will stop at its closed position automatically if the limit switch is reached Then move the first and the second switches of SW DIP switch to OFF position up immediately Thus the width of pedestrian mode has been reserved the auto close function of pedestr
26. unt varies on the time of the year Make sure you account for all this in any solar installation If insufficient power is available the opener battery can be permanently damaged and this is not covered under the warranty Diagram 2 Parts List Sliding gate operator Operator Base 1 1 1 Magnetic limit switch 2 Remote control 2 Master Links and chain bolts 2 10 ft Chain 2 Chain Bolts 2 Chain Brackets 4 U Bolts for 2_ 51mm for square amp round gate frame 4 24 70mm 48 Bolts for mounting operator to the base and washers 4 2 _ 64mm Bolts for mounting Magnet brackets and washers 4 3 4 Anchor bolts Anchors Washers and Nuts In the same bag with Manual release key 4 5 8_ 15mm Socket Head Cap screws for mounting chain box 2 Manual release key 2 Magnet brackets 2 Magnets 1m BVR 0 7mm antenna Screwdriver Owner s manual zel il ed Seen es ee ee J ak ee ens en es en ed we Ne TA er en Lis PE SE SE se aer ae J Se l salen sazan er Chain Box Upper guiding Sliding gate Power socket and plug Chain bracket Tansformer A weatherproof Release here housing or cover must be used Gate operator Use PVC conduit through the concrete pad Chain Chain bracket Fig 1 6 Mechanical Installation Installation and Ad
Download Pdf Manuals
Related Search
Related Contents
Medana Operational&M.. 取扱説明書を見る - AQUA(アクア)|ハイアールアジア株式会社 Premium Software User Manual The Book!! Manual Bomba Centrífuga de eje libre y conexiones Mode d`emploi de l`adhésif pour Hypalon Dell Inspiron 2500 Service manual Xpelair FR22-30 User's Manual (12) United States Patent Beko GG 15120 DX PR cooker S360 Stereo Panner, Imager User Manual Copyright © All rights reserved.