Home

1 - Farnell

image

Contents

1. OMRON E5CS E Accessories Order Separately 8 pin Sockets without Alarms Terminal Arrangement Internal Connections Top View P2CF 08 Front Connecting Socket Eight M3 5 x 7 5 J sems screws a ee 3 5 F NA L Two 4 5 dia 4 holes Mounting Hole Dimensions Two 4 5 dia hole or two M4 40 0 2 Note DIN Track mounting is also possible 70 max Note The P2CF 08 E Socket with finger protection is also available 20 3 max Terminal Arrangement Bottom View a Note The Y92A 48G Finger Safe Terminal Cover is also available 11 pin Sockets with Alarms Terminal Arrangement Internal Connections H 45 Top View P2CF 11 Front Connecting Socket Eleven m3 5 x7 5 sems screws 78 3 a j E j g a p a Mounting Hole Dimensions Two 4 5 dia mounting holes m 40 0 2 al Note DIN Track mounting is also possible 31 2 max Note The P2CF 11 E Socket with finger protection is also available Terminal Arrangement Bottom View i eaa NCAA d Note The Y92A 48G Finger Safe Terminal Cover is also available Note Do not use any other types of Sockets Doing so will adversely affect the accuracy Applicable Thermistors Hard Protective Cover Use Element Interchangeable Thermistors E52 THE5A E52 The Y92A 48B Hard Protective Cover is available for the following THE6D and E52 THE6F to connect to the E5CS LIGU
2. Plug in Without Voltage output models See note 1 Voltage output models See note 1 models alarms Voltage output models See note 1 12 VDC 12 VDC 12 VDC 21 mA 21mA 21 MA 7 Voltage Voltage Voltage output output output Relay output models Relay output models Relay output models T egos 100 to 240 VAC 100 to 240 VAC 100 to 240 VAC 24 VAC VDC 24 VAC VDC 24 VAC VDC See note 2 See note 2 See note 2 Voltage output models Two alarm Voltage output models Two alarm Voltage output models See note 1 points See note 1 points See note 1 12 VDC 21 mA 12 VDC 21 mA 12 VDC 21 mA PUET OUT OUT p Can output 1 Alarm output 1 a Alarm output 2 O Alarm output 2 o Relay output models Relay output models Relay output models Alarm output Alarm output Alarm output nga 1000 0 0 8o 0p O U e585 100 to 240 VAC 100 to 240 VAC 100 to 240 VAC 24 VAC VDC 24 VAC VDC 24 VAC VDC See note 2 See note 2 See note 2 Note 1 The voltage output 12 VDC 21 mA is not electrically isolated from the internal circuits When using a grounding thermocouple do not connect output terminals 4 or 5 to ground Otherwise unwanted current paths will cause measurement errors 2 Models with 100 to 240 VAC and 24 VAC VDC are separate Models using 24 VDC have no polarity Be sure to check the sensor type before using multi output thermocouple platinum resistance thermometer models Nomenc
3. For details applications olin eNOS TEIRRI EA e To protect the set from dust and dirt e To prevent the panel from being accidentally touched causing displacement of set values e To provide effective protection against water droplets OMRON E5CS Safety Precautions Refer to Safety Precautions for All Temperature Controllers Refer to E5CS E5CSV Operation for operating procedures ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 038937 To convert grams into ounces multipl In the interest of product improvement specifications are subject to change without notice OMRON Read and Understand This Catalog Please read and understand this catalog before purchasing the products Please consult your OMRON representative if you have any questions or comments Warranty and Limitations of Liability WARRANTY OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year or other period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS O
4. 2 200 0 Setting number i l __ The shaded value indicates the default Minimum setting unit setting status Temperature Input range 500 selected using switch Default setting 3 Setting number The shaded value indicates the default Minimum setting unit 1 setting status Input Temperature ae ie 30 G 550Q 4kQ ie 6kQ 30kQ 550Q 4kQ range a 0 C 0 C 200 C 200 C 0 C 0 C 0 C 200 C 200 C selected 500 J using switch 300 200 100 Default setting 1 100 Setting number The shaded value indicates the default Minimum setting unit O O OOOO SSS o e SO O O O Oo sting status Universal input Thermocouple Platinum Resistance Thermometer Models e Using Thermocouple Sensors Control Mode Switch 5 OFF Temperature range selected using switch Default setting 0 Setting number __ The shaded value indicates the default setting status Minimum setting unit Temperature range selected using switch Default setting 0 Setting number The shaded value indicates the default Minimum setting unit l 1 setting status OMRON E5CS External Connection Diagram Thermocouple See note 3 Platinum resistance thermometer Thermistor See note 3
5. Light Gray Thermistor Power Supply Voltage 24 VAC VDC Type Control Model with thermistor modes E5CS U Plug in ON OFF or iO 8s Relay ESCS RGDU W RGDU W 48 x 48 mm PID ft aed oe R1GDU W E Accessories Order Separately Socket without Alarm 8 Pins Socket with Alarm 11 Pins Pope Moet type Met Front Connecting Socket P2CF 08 Front Connecting Socket P2CF 11 Back Connecting Socket flush mounting P3G 08 Back Connecting Socket flush mounting P3GA 11 Front Connecting Socket with finger protection P2CF 08 E Front Connecting Socket with finger protection P2CF 11 E Finger Safe Terminal Cover for P3G Y92A 48G Finger Safe Terminal Cover for P3G Y92A 48G Protective Cover pType Mel Hard Protective Cover Y92A 48B OMRON E5CS Specifications E Ratings Supply voltage 100 to 240 VAC 50 60 Hz 24 VAC 50 60 Hz 24 VDC Operating voltage range 85 to 110 of rated supply voltage Power consumption 100 to 240 VAC 5 VA 24 VAC 3 VA 24 VDC 2 W Thermocouple K J Lb Platinum resistance thermometer Pt100 JPt100 Thermistor E52 THELIL Universal input thermocouple platinum resistance thermometer K J L T U N R Pt100 JPt100 Relay output SPDT 250 VAC 3 A resistive load Voltage output 12 VDC 21 mA with short circuit protection circuit for driving the SSR Control method ON OFF or 2 PID with automatic PID parameter setting function SPST NO 250 VAC 1A resistive load Setting met
6. imply that the uses listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitions of use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user s programming of a programmable product or any consequence thereof Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change model numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the products may be changed without any notice When in doubt special model numbers may be assigned to fix or establish key specific
7. is greater 1 digit max of PV or 4 C whichever is greater 1 digit max Platinum resistance thermometer inputs 1 of PV or 2 C whichever is greater 1 digit max Thermistor 2 FS 1 digit max 0 2 FS 0 1 FS for universal input thermocouple platinum resistance thermometer models 1 to 999 C automatic adjustment using auto tuning self tuning 1 to 1 999 s automatic adjustment using auto tuning self tuning 1 to 1 999 s automatic adjustment using auto tuning self tuning Absolute value alarm Same as the control range Other 0 to input setting range full scale C or F Alarm hysteresis 0 2 C or F fixed Control period E E Shock resistance Malfunction 100 m s min 3 times each in six directions Destruction 300 m s min 3 times each in six directions Life expectancy Electrical 100 000 operations min relay outputmodels SOS Weight S Hysteresis for ON OFF control Proportional band P Integral time I Derivative time D Alarm output range Approx 110 g Controller only Degree of protection Front panel Equivalent to IP50 Enclosure Category 2 IEC 60529 Rear case IP20 Terminals IPOO EEPROM non volatile memory number of writes 1 000 000 EMI Radiated EN 55011 Group 1 Class A UL 61010 1 listing EMI Conducted EN 55011 Group 1 Class A Radiated Electromagnetic Field Immunity EN 61000 4 2 4 kV contact discharge level 2 Approved standards CSA C22 2 No 1010 1 Conform
8. F LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products At the customer s request OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attention must be given This is not intended to be an exhaustive list of all possible uses of the products nor is it intended to
9. Temperature Controllers E5SCS Simple Functions in DIN 48 x 48 mm size Plug in Temperature Controllers 071V M 151 07S DAS o e Easy setting using DIP switch e Models with two alarms added to Series ideal for applications requiring alarms e Universal input thermocouple platinum resistance thermometer models also available e Clearly visible digital display with character height of 13 5 mm e RoHS compliant c UL us C Refer to Safety Precautions for All Temperature Controllers Refer to E5CS E5CSV Operation for operating procedures Model Number Structure E Model Number Legend Plug in Models E5CS UULLU W 12345 6 1 Control Outputs 3 Input 4 Power Supply Voltage R Relay KJ Thermocouple Blank 100 to 240 VAC Q Voltage for driving SSR P Platinum resistance thermometer D 24 VAC VDC 2 Alarm Outputs G Thermistor 5 Terminal Shape Blank No alarm T Thermocouple platinum resistance U Plug in 1 1 alarm thermometer universal input 6 Case Color 2 2 alarms W Light gray Note A functional explanation is provided here for illustration but models are not necessarily available for all possible combinations Refer to Ordering Information when ordering Examples e Relay control output without alarm thermocouple input plug in construction light gray case E5CS RKJU W e Relay control output one alarm output platinum resistance thermometer input plug in constru
10. ations for your application on your request Please consult with your OMRON representative at any time to confirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of OMRON s test conditions and the users must correlate it to actual application requirements Actual performance is subject to the OMRON Warranty and Limitations of Liability ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions 2011 12 In the interest of product improvement specifications are subject to change without notice OMRON Corporation Industrial Automation Company http www ia omron com c Copyright OMRON Corporation 2011 All Right Reserved
11. ction light gray case E5CS R1PU W oOmRon E5CS Ordering Information E List of Models Case Color Light Gray Thermocouple or Platinum Resistance Thermometer Power Supply Voltage 100 to 240 VAC Type Control Model with Model with platinum modes thermocouple resistance thermometer ECSU Pugin ONOFF or 48x48 mm PID ee E Case Color Light Gray Thermocouple or Platinum Resistance Thermometer Power Supply Voltage 24 VAC VDC Type Control Model with Model with platinum modes thermocouple resistance thermometer ECSU Plugin ONOFF or 48x48 mm PID Voltage for arving SSA Escs OKUW i a cere n Case Color Light Gray Thermistor or Universal input Power Supply Voltage 100 to 240 VAC Type Control Model with thermistor Model with universal modes input thermocouple and platinum resistance thermometer E5CS U Plug in ON OFF or E5CS RGU W E5CS RTU W 48 x 48 mm PID ea for driving SSR E5CS QGU W E5CS QTU W Reay ES0SRIGUW_ __ E5OS RITU W for driving SSR E5CS Q1GU W E5CS Q1TU W g re es m E5CS Q2TU W Voltage for driving SSR for driving SSR Note There is no alarm output 2 mode switch The default setting for alarm output 2 is for the upper limit alarm mode To change the setting change the alarm type for alarm output 2 in initial setting level 5 For details refer to the ESCSV E5CS U Digital Temperature Controller User s Manual Cat No H140 E1 01 Case Color
12. ed standards EN 61326 EN 61010 1 IEC 61010 1 8 kV air discharge level 3 EN 61000 4 3 10 V m 80 1000 MHz 1 4 2 0 GHz amplitude modulated level 3 10 V m 900 MHz pulse modulated EN 61000 4 6 3 V 0 15 to 80 MHz level 2 EN 61000 4 4 2 kV power line level 3 1 kV I O signal line level 3 EN 61000 4 5 Power line Normal mode 1 kV Common mode 2 kV Output line relay output Normal mode 1 kV Common mode 2 kV EN 61000 4 11 0 5 cycle 100 rated voltage The following exceptions apply to thermocouples e U L 2 C 1 digit max eR 8 C 1 digit max at 200 C or less The following exception applies to platinum resistance thermometers e Input set values 1 for E5CS U 1 FS 1 digit max The following exceptions apply to thermistors e When the unit setting is C temperature indication ranges exceeding the set temperature range 10 FS may not be accurate e When the unit setting is F the temperature range for the input setting numbers 4 and 9 609 to 630 F and temperature indication ranges exceeding the set temperature range 5 FS to 10 FS may not be accurate RF interference Immunity Conducted Disturbance Immunity Noise Immunity First Transient Burst Noise Burst Immunity Surge Immunity Voltage Dip Interrupting Immunity OMRON E5CS E Temperature Range Thermocouple Input Models Temperature 1 000 range ae selected 700 using switch aes 400 300 Default setting
13. hod Digital setting using front panel keys Indication method 7 segment digital display character height 13 5 mm and deviation indicators Other functions e Setting change prohibit key protection e Input shift e Temperature unit change C F e Direct reverse operation e Temperature range Sensor switching K J L Pt100 JPt100 e Switching is performed between a thermocouple and platinum resistance thermometer for universal input models e Control period switching e 8 mode alarm output e Sensor error detection excluding thermistor models Ambient operating 10 to 55 C with no condensation or icing with 3 year guarantee 10 to 50 C temperature Ambient operating humidity 25 to 85 Storage temperature 25 to 65 C with no condensation or icing Note Do not use an inverter output as the power supply Refer to Safety Precautions for All Temperature Controllers OMRON E Characteristics Setting accuracy Thermocouple See note 1 Indication accuracy ambient temperature of 23 C Thermistor See note 3 Influence of temperature R thermocouple inputs Other thermocouple inputs 2 2 Influence of voltage E5CS 1 of indication value or 2 C whichever is greater 1 digit max Platinum resistance thermometer See note 2 40 5 of indication value or 1 C whichever is greater 1 digit max 1 FS of indication value 1 digit max of PV or 10 C whichever
14. lature E5CS U Plug in Models Temperature display Output indicator Deviation indicators Mode indicators Alarm indicators Mode Key Up Key omron E5CS Down key OMRON E5CS Dimensions Note All units are in millimeters unless otherwise indicated E Controller E5CS U Terminal Arrangement Bottom View e 94 45 m oV a p T ITI vf a vi Models without Models with alarms alarms Panel Cutout Dimensions lt 45 D gt Note The external dimensions are the same for both models with and without alarms L 48xN 2 5 5 Mounting side by side group mounting of N Controllers E5CS U Adapter for Flush Mounting Enclosed Back Connecting Socket Order Separately Without Alarms Adapter for Panel Y92F 30 Adapter for flush mounting flush mounting P3G 08 Back Connecting Socket ns a SP ALM ALM 1 2 Co Ar ui omron E5CS D gt 7l 95 E5CS U Adapter for Flush Mounting Enclosed Back Connecting Socket Order Separately With Alarms Adapter for Panel Y92F 30 Adapter for flush mounting flush mounting P3GA 11 Back Connecting Socket SA a F LI Tightening screws gt 74 100 gt Note Use the P2CF 08 and P3G 08 Sockets for models without alarms and use the P2CF 11 and P8GA 11 Sockets for models with alarms

Download Pdf Manuals