Home

Yokogawa Electric FA-M3 PLC Ladder Monitor Operation Manual

image

Contents

1. 11 columns x 5 rows For details regarding comments 2 4 4 Comments page 2 15 2 3 2 Ladder Diagrams Types of ladder diagram screen data are shown below Row Number Circuit Comment 00007 k Sub Comment Initialization Rout ine 00008 OOOO PN MOCCAD seco nd cl ock rds 2d _ O Comment Current Value Instruction Number 2 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual 2 4 Screen Operation 2 8 The following information explains how to operate the Ladder Monitor screen LADDER MONI END m TI c mr c un m CJ TI T AJ c2 E wa Lam 8 um co zm a Quits the PLC Ladder Monitor software The GP unit is reset and switches to ONLINE mode Reads in the PLC s ladder programs Switches the style of data display between decimal hexadecimal and decimal point Starts the Device Monitor feature The Monitor MENU will appear Calls up the Search Menu to search for ladder program data Changes the I O comment display format Scrolls through the ladder diagram one row at a time Scrolls through the ladder program one page at a time Chapter 2 Operation 2 4 1 PC Read Touching the main screen s FEAL key displays the PC READ INPUT Block screen Here enter the block no to be displayed at the beginning of the ladder program list See Select Read Block screen below
2. Prior to running the installer program GP PRO PB III for Windows Ver 5 0 or later screen editor software must be installed on your system Refer to the section of the GP PRO PBaV for Windows Setup Guide that relates to your unit s OS 2 1 2 Project File Creation Running Create a new project file or run an existing project file For project file details GP PRO PB III for Windows Operation Manual Included with the screen editor software 2 1 3 Device Monitor Registration Register the Device Monitor feature in your project Starting from the screen editor software s main screen the procedure for registering the Device Monitor fea ture is explained below B Registering the Device Monitor screen Select the Screen Setup menu s Device Monitor feature Click Add to register the feature Device Monitor Device Monitor Files are nat in the current project Fress the Add button ta add the files to the project English C Japanese Add Cancel Help NOTE To register the Device Monitor feature at least 125KB of free GP space must be available Therefore after sending your project to the GP unit be sure to check that at least 125KB of space is remaining for this feature You can check the amount of GP memory used by your project via the Project Manager s Project gt Property screen 2 2 Chapter 2 Operation The following screen appears if the Device Monitor feature has already been registe
3. 4 2 1 6 Insert the CF Gard Into the GP 2 4 2 1 7 Gonnect the GP to The PEG a ee 2 4 2 2 PLC Ladder Monitor Feature Startup ccccceececsseeeeceeeeeeseeseeseeeeeeseeeeeeeas 2 5 2 2 1 Via the Menu Bar aaa EHE 2 5 2 2 2 Turning the Extended Special Relay Area ON wwwmmmmwmamanwnamamw mnamwamini 2 6 2 9 SCHEEeN NANOS nee iii 2 7 2 3 Mec RETI Uu UL lentes 2 7 2 3 2 Ladder DIAG als sa san ea 2 7 2 4 Screen ODEN AU ON Lm 2 8 221 PS Reale TRU 2 9 2 4 2 DeEeVice MONA Eee 2 10 20 3 OC ANC MI COUN nn ai AAA AAA WA WA AA 2 11 2 Aa Re MITTEN Nu 2 14 2 5 Usage CSINICIOMS WA een 2 16 ZAM INO e RE A a E 2 16 25 2 ONE C 2 16 CHAPTER 3 Errors Oe EHORIMESSAgESs ve E I I T TRU 3 2 Documentation Conventions This manual uses the following symbols and terminology PORTANT Screen editor software Indicates a potentially damaging action or dangerous situation that could result in abnormal equipment operation or data loss Indicates GP PRO PB III for Windows Indicates a Programmable Logic Controller Also known as sequencer Indicates useful or important supplemental information Provides useful or important supplemental information Indicates related information Related Units B Related PLC units The table below lists the PLC units that can be used with the Add on Kit Link I F or Connection Device Type Series Name CPU CPU di
4. feature enables you to 1 Read PLC ladder programs and display them on the GP unit via Ladder Monitor 2 Monitor change arbitrary PLC device addresses via Device Monitor After Ladder Monitor is started the GP switches to ladder monitor mode Device Monitor mode can be used when the GP is in ladder monitor mode as well as in online RUN mode Online Mode RUN mode GP Device Features Monitor Device Monitor Menu Bar 8 point push type menu j Offline Monitor Offline Ladder Monitor Mode Mode Offline Mode Ladder Device Monitor Monitor gt GP d RUN Reset E Return to Offline Mode IMPORTANT The GP unit will be reset if you switch from online mode to ladder monitor mode 1 4 Chapter 1 Overview and Setup 1 2 Installation Procedure The following flowchart explains the procedure necessary for installing the Add on Kit It is assumed that GP PRO PB III for Windows is already installed and that the ladder program has been transferred to the PLC Add on Kit Installation SEE 2 1 1 CD Installation page 2 2 Install the PLC Ladder Monitor Add on Kit 2 1 2 Project File Creation Running page 2 2 GP PRO PB III for Windows Operation Manual Included with the screen editor software Project Creation Startup Create a new project file or start an existing project o o m m m m illi Registering Device Monitor feature 2 1 3 Device Monitor Registration page 2 Registe
5. AST p qu ww 2 TOP Searches for and displays the ladder program s first instruction number LAST Searches for and displays the ladder program s last instruction number 2 12 Chapter 2 Operation B Device Search Coil Search Touching the Device Search key displays the Search Device screen Touching the Coil Search Select the type of search to perform ee key displays the Search Coil screen Please select a type of device Displays other device type characters RET Returns to the Search Menu After you select the device type the following screen appears Here enter the device address Use the charac ter keys to enter the device address and press to start the search Search Device e pom gt E LAE LE e Device x 00000000 Flease enter an address PE PET C jo EN 2 13 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual Searching for the designated device address The circuit is displayed with the designated device address at the top of the main screen Next a screen that enables you to search for identical device addresses s displayed SCHE COAL Device D 00000030 Flease select a search command Starting from the current ladder rung searches backward for identical device REV addresses until the first row of the program is reached a Starting from the current ladder rung searches forward for identical device NEAT
6. Do vou read Ladder Program Plaese Input an Block Mo Block No LD 17 Time 00 Title P 13 31 5 09 3 2003 0 2 ALARM 1917 1750 2001 1 3 OUTPUT 302 318 2001 1 4 FID 373 373 2002 0 zi 2 g KUADI 389 488 2001 11 To select a ladder program touch the block name of the ladder program block you want to read out A mark will be displayed to the left of the ladder program you selected Touching the block name again will can cel the selection The maximum number of ladder programs that can be displayed is 10 Designates the block no to be displayed at the beginning of the ladder pro ais gram list Touching SET No calls up the PC READ INPUT Block screen This designates the drive used when reading out data The drive selected is then shown in the upper section of the screen to the right of the word LD LADDER DRIVE To The End Reads in selected ladder program data up to its END instruction All Area Reads in all selected ladder program data Scrolls through the ladder program list one page at a time f 2 9 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual NOTE At this time Title column data cannot be displayed e A linthe P column indicates that the ladder program is protected Protected ladder programs cannot be read in Concerning the Readout Drive The readout drive designates the drive used to read out ladder information Sim
7. GP internal memory s extended special relay LS2078 s bit 1 This will start up the PLC Ladder Monitor feature LS2078 Reserved Reserved 1 Start Ladder Monitor Reserved Read out cache data Bit 1 Turning this bit ON starts the Ladder Monitor The Ladder Monitor menu will not appear Bit 3 Immediately after the Ladder Monitor starts turning this bit ON displays the ladder program cached in the CF card When using Bit 3 be sure to turn Bit 1 ON at the same time cf Related Units Related GP Units If there is no cache data on the CF card simply turning Bit 1 ON will read out the current data Prior to using the Cache feature the data must be read into a PC one time NOTE I All other bits are reserved Do not write data to any of these bits 2 6 Chapter 2 Operation 2 3 Screen Names The following sections explain PLC Ladder Monitor screen layout 2 3 1 Main screen The PLC Ladder Monitor s main screen contains the following information Power Lines Power Lines Ladder Diagram Ladder Data Comments Sub Comments Instruction Number Label Error Display Area The number of rows that can be displayed on the screen varies depending on the comment mode There are three comment modes e No comment mode 11 columns x 8 rows e Comment mode 11 columns x 3 rows e Compressed comment mode
8. Manual 1 1 Overview The PLC Ladder Monitor software enables you to read PLC ladder programs and display them as ladder dia grams on the GP unit This software operates on the GP unit and the software s boot file is stored in the GP unit s CF Card The PLC Ladder Monitor Add on Kit has the following features SEE Displays PLC ladder programs as ladder diagrams Displays power ON lines using bold lines Displays the designated instruction number Displays circuit data including the designated device address Displays circuit data in which the designated device address is included in the output instruction Displays ladder program comments Calls the Device Monitor feature Use the Device Monitor feature to set reset or change the value of an arbitrary device this feature GP PRO PBIII for Windows Device PLC Connection Manual Included with the screen editor soft ware NOTE The Device Monitor feature is not explained in this manual For information on how to operate 1 2 Chapter 1 Overview and Setup 1 1 1 System Design The GP and the PLC are connected in a 1 1 relationship Connect one end of the cable to the GP unit s serial interface port and the other end to the PLC unit s CPU module programming tool connector Yokogawa Electric s Programming Tool Cable KM11 2N A 1 3 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual 1 1 2 Operation Mode The PLC Ladder Monitor
9. Pro face Human Machine Interface Yokogawa Electric FA M3 Pro face PLC Ladder Monitor Operation Manual Preface Thank you for purchasing Pro face s PLC Ladder Monitor Add on Kit for the Yokogawa Electric FA M3 PLC This man ual Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual explains how to operate the PLC ladder mon itor featuer and device monitor featuer while using Pro face s GP2000 series operator interfaces Be sure to read this manual carefully to understand how to correctly use your PLC Ladder Monitor Add on Kit Be sure to keep this manual close at hand for easy reference Notice The copyrights to all programs and manuals included in the PLC Ladder Monitor Add on Kit for Yokogawa Electric s FA M3 PLC hereinafter referred to as this product are reserved by the Digital Electronics Cor poration Digital grants the use of this product to its users as described in the Software Operating and License Conditions section Any actions violating the above mentioned conditions are prohibited by both Japanese and foreign regulations The contents of this manual have been thoroughly checked However if you should find any errors or omis sions in this manual please contact your local representative and inform them of your findings Please be aware that Digital Electronics Corporation shall not be held liable by the user for any damages losses or third party claims arising from the uses of this product Di
10. addresses until the last row of the program is reached End Exits the search feature and returns to the main screen RET Returns to the Search Menu When the designated device address is not found The following screen is displayed when the device address search is unsuccessful TEE STILLE Device D 00000030 Not found Flease select a search command B Using a double touch to search for a coil When you touch the device address displayed on the main screen twice in succession the output instruction containing the designated address appears at the top of the main screen This is similar in function to the coil search 2 14 Chapter 2 Operation 2 4 4 Comments There are three types of comments e Circuit comment e Sub comment e O comment Row Number Circuit Comment 10007 k Sub Comment Initialization Rout ine nun MOCCOAL OOOO ZN Init seco nd cl ack O Comment Current Value Instruction Number B Circuit comments Circuit comments can only be displayed for data from an F3SP S model CPU 65 single byte characters Comments cannot be displayed for data from other model CPUs The comment zoom feature can also be used E Sub comments Sub comments can only be displayed for data from an F3SP S model CPU 8 single byte characters x 3 rows Sub comments cannot be displayed for data from other model CPUs With sub comments however the comment zoom featu
11. by bold thick lines However lines connecting two contacts are displayed normally e The main screen is displayed at the GP unit s center at 640 x 400 resolution Blank space may be displayed at the top bottom left or right corners of the screen depending on the PLC model used e The comment zoom feature can display a maximum of 72 single byte characters When Ladder End is displayed at the end of a circuit the maximum number of characters that can be displayed is 70 single byte characters e Local devices with attached cannot display the character The character will not be displayed on the ladder monitor and the device address may change suddenly e SCALL instruction notation differs from that used in Yokogawa Electric s FA M3 program development tool Wide Field The SCALL instruction is broken into multiple instructions and stored on the CPU Therefore when the SCALL instruction is read it s displayed as multiple instructions cf Next figures e ACTX IACTX SRRD AMOV ABMOV instructions are not supported If these instructions are used a circuit error will occur and the ladder logic following the circuit where it is used will not be displayed e Ifthe last line of a ladder block is circuit comment the circuit comment is not displayed 2 5 2 Others e When 32 bit instructions are used the designated device address and designated device address 1 are read As a result designating a device s maximum address
12. d correctly Insert the CF Card correctly and read the comment file again 3 3 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual Memo 3 4
13. der Yokogawa Electric s FA M3 Ladder Monitor boot file filename FA ACEI SYS To copy this program to a CF card the card must have at least 2MB or more free space 2 1 6 Insert the CF Card into the GP Remove the CF Card from your PC s card reader and insert it in the GP unit s CF Card socket For CF Card socket insertion details Your GP unit User Manual Separately sold 2 1 7 Connect the GP to the PLC Connect the data transfer cable between the GP and the PLC For cable connection details 1 1 1 System Design page 1 3 GP PRO PB III for Windows Device PLC Connection Manual Included with the screen editor soft ware 2 4 Chapter 2 Operation 2 2 PLC Ladder Monitor Feature Startup Either of the following two methods can be used to start the PLC Ladder Monitor feature 2 2 1 Viathe Menu Bar 1 To call up the GP screen s Menu Bar simultaneously press the areas marked by 1 ii and ill See below 2 After the Menu Bar appears select MONITOR 1 3 CF BOOT MONITOR OFFLINE RESET CANCEL NOTE I Ifthe Device Monitor feature has not been registered correctly the MONITOR button will not be displayed in the Menu Bar 2 1 3 Device Monitor Registration page 2 2 3 Menu screen is displayed touch the Ladder Monitor button 2 5 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual 2 2 2 Turning the Extended Special Relay Area ON Use a bit switch etc to turn ON the
14. fferences may occur between the descriptions found in this manual and the actual functioning of this prod uct The latest information about this product is provided in the accompanying data files i e Readme txt files etc and or separate documents Please consult these sources as well as this manual prior to use Even though the information contained in and displayed by this product may be related to intangible or intel lectual properties of the Digital Electronics Corporation or third parties the Digital Electronics Corporation shall not warrant or grant the use of said properties to any users and or other third parties All product names used in this manual are trademarks or registered trademarks of their respective owners c 2004 Digital Electronics Corporation All rights reserved Table of Contents milicie ii near IAEA 1 NA AAA 1 Table Ol IA IA 2 Documentation CONVENUONS AAA 3 REA BIBIT m 4 CHAPTER 1 Overview and Setup Me A ANI TM 1 2 KUSUSIA 1 3 Le AV aa aa UE AAA WAWA WA WAA 1 4 12 NASMA Procedure AKA reacts Y eU ER dE tos e fa e 1 5 CHAPTER 2 Operation 2A MST ANAM OM eas RETE 2 2 2 1 1 DUnStalalonzanzs c 2 2 2 1 2 Project File Creation Running Wa nennen 2 2 2 1 3 Device Monitor Registration us0220000020800 0nnnnnnnnn nennen nennen neuen nennen nennen 2 2 2 124 FOSS CU Transl o nes ee WA AAA AA AAA WAA 2 4 2 1 5 Copy Boot File to a CF Card esee nennen nennen nnn 2
15. ng writ correctly ing Check whether the capacity of CF Availability of CF card is insufficient card is vacant System file of a ladder monitor does Check whether a FA_ACELSYS A file is not found D not exist file exists in CF card Check whether there is any ladder The read data was not convertible command to which the ladder moni for the ladder figure tor does not correspond A cable is extracted during read out Check whether a cable with PLC is of a ladder correct and PC read out is per formed again Cannot write to CF Card L adder error 1 When a circuit error occurs the rudder display and reference after it cannot be performed The error message is detected when either of the following two conditions are satisfied 1 When screens are changed to display a new page 2 When a file s data is read again Solutions to the above errors vary depending on when the error occurred Error Occurrence Internal Processing Recovery Suspends processing after error message is displayed After recovery processing continues Insert the CF Card correctly When reading the lad der program 3 2 When reading the comment file When the comment is being displayed Suspends processing after error message is displayed After recovery processing continues Turns OFF comment display after error message is displayed Continue processing as before Chapter 3 Errors Insert the CF Car
16. nitor Block Monitor m Monitor details GP PRO PB III for Windows Device PLC Connection Manual Included with the screen editor soft ware NOTE This manual does not explain Device Monitor feature operation or related details For Device SEE 2 11 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual 2 4 3 Search Feature Touching the main screen s SEARCH key displays the Search Menu This screen is used to designate the instruction number or device address of the circuit that will appear at the aoe TRES ty ty top of the main screen Please select a search command Instruction Numbers earc CEN Coil Search Used to designate the instruction number of the circuit that will appear at the top of the main screen Used to designate the device address of the circuit that will appear at the top of the main screen Instruction Numbers eare Coil 8 I Used to designate the output instruction containing the device address of the circuit that will appear at the top of the main screen B instruction Numbers Search Touching the Inst ruct ion Numbers Search nate an instruction number Use the screen s numeric keys 1 to 0 to enter an instruction number and press to start the search Search rat Tuners Fr Pon gt el Inst ruct ion Numbers 000000 key displays the Search Inst Numbers screen which is used to desig Please enter a Instruction Numbers ps fo fo Tor L
17. nt files Comment zoom feature Touching a comment in the main screen will display that comment s entire text in the main screen s lower left corner I O Comments 32 single byte characters Circuit comments 72 single byte characters 2 16 Chapter 2 Operation 2 5 Usage Restrictions 2 5 1 Notation When monitoring bit devices used in a function instruction dividing the bit address by 16 and adding 1 calculates the word address e When displaying monitored data using decimal point display apart from the FLOAT attribute s device address all 32 bit attribute device addresses will also be displayed using decimal point display 16 bit attribute device addresses will not be displayed This decimal point display differs from Yokogawa Elec tric s program development tool Wide Field which uses exponential display e A maximum of 8 digits can be displayed for monitor data If the number of digits exceeds 8 only the first eight digits will be displayed e For a circuit the maximum number of rows that can be displayed is 25 If the circuit contains more than 25 rows rows from the 26th row will be omitted and only the first 25 rows will be displayed Also when searching for a device if an abbreviation has been used for the device when it is found the device itself will not be displayed however the start of the circuit that contains the device will be shown e Contacts coils and frames through which power flows are indicated
18. ply press the button use the following steps to search for the file and the current file will be displayed Only PG is displayed when using a unit that SACHE function is not available PG gt CACHE PG This reads out the ladder program from the PLC and displays it Also when using a unit that CACHE function is available ladder data will automatically be cop ied to LADMON folder of the CF card The name of this file will be FA ACEI CCH CACHE cf Related Units Related GP Units When the Ladder Program is read out that data file name FA ACEI CCH is saved automatically to LADMON folder of the CF card However when using CACHE the ladder program stored in the CF card is read out and displayed Since no communication is being performed with the PLC this readout can be dis played very quickly Display begins from the screen that was last displayed using the Ladder Monitor feature The ladder logic information shown by CACHE is for the previously read out PLC ladder logic data If the PLC s ladder logic data has been changed or updated or if the PLC has been changed be sure to read out the latest ladder logic data from the PLC 2 10 Chapter 2 Operation 2 4 2 Device Monitor Touching the main screen s MONI T key displays the Monitor MENU The Device Monitor feature allows you to monitor PLC devices Monitor MENU Dom lt A Select the Monitor modes Random Mo
19. r the Device Monitor feature in your SEE gt 2 project SEE 2 1 4 Project Transfer page 2 4 Send project SEE gt GP PRO PB III for Windows Operation Misses dne pro do re GU mit Manual Included with the screen editor software Copy boot file to CF Card 2 1 5 Copy Boot File to a CF Card page 2 Copy the PLC Ladder Monitor feature boot file 4 to the CF Card Insert CF Card 2 1 6 Insert the CF Card into the GP l page Insert the CF Card containing the PLC Ladder 2 4 Monitor feature into the GP unit s CF Card socket Connect GP to PLC SEE 1 1 1 System Design page 1 3 Connect a data transfer cable to the GP and the PLC SEE 2 1 7 Connect the GP to the PLC page 2 4 ble Start Ladder Monitor SEE gt 2 2 PLC Ladder Monitor Feature Startup Turn the GP and PLC units ON and start the page 2 5 Ladder Monitor feature 1 5 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual Memo 1 6 2 Operation 2 1 Installation 2 2 PLC Ladder Monitor Feature Startup 2 3 Screen Names 2 4 Screen Operation 2 5 Usage Restrictions 2 1 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual 2 1 Installation Please perform the following installation procedure prior to using the PLC Ladder Monitor feature 2 1 1 CD Installation In Windows Explorer double click on the CD s Setup exe file to start the installer program Follow the installer program s directions IMPORTANT
20. re cannot be used B I O comments Touching the main screen s co key displays I O comments Touching the Comment mode gt Compressed comment mode gt No comment mode key changes the comment mode in the following order In comment mode a maximum of 5 single byte characters x 3 rows can be displayed In compressed comment mode a maximum of 5 single byte characters x 3 rows can be displayed Characters are compressed to half the original length If the device comment of the next column is used up to 5 signal byte characters x 2 rows can be seen in a device s comment display To display all comments please use the Comment zoom feature Circuit comments and sub comments are displayed normally regardless of the comment mode 2 15 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual To display comments the project folder s comment files YCMN Created using the Yokogawa Electric FA M3 program development tool Wide Field are required First change these files file extensions to CMN and copy them to the CF Card For each ladder program you read from the PLC unit a comment file with the same name will be automati cally read The comment zoom feature can be used IMPORTANT e Although there are two types of comment files one with a YSIG Block tag defi nition and the other with a YCMN Common tag definition extension be sure to use only YCMN Common tag definition comme
21. rect in Screen Cable connection Editor F3SP21 0N F3SP25 2N F3SP28 3N i d au Yokogawa Yokogawa d Electric s Electric FAC Yokogawa FACTORY F3SP53 4H CPU direct Programming TORY ACE Electric ACE F3SP58 6H connection l Tool Cable 1 1 Communi oe KM11 2N A cation F3SP38 6S F3SP53 4S F3SP58 6S F3SP59 7S B Related GP units The table below lists the GP units that can be used with the Add on Kit software Also to use the Cache Function on a GP GLC unit the unit s revision code must be the same as or higher than those listed below GP 2401HT GP2401H TC41 24V GP 2400T GP2400 TC41 24V GP 2401T GP2401 TC41 24V GP2500 TC11 GP 2500T GP2500 TC41 24V GP 2000 Series GP 2500S GP2500 SC41 24V GP 2500L GP2500 LG41 24V GP 2501T GP2501 TC11 GP 2501S GP2501 SC11 GP 2501L GP2501 LG41 24V GP 2600T GP 2601T GP2601 TC11 2 GLC2400T GLC2400 TC41 24V GLC2500 TC41 24V All Rev GLC2500T GLC2500 TC41 200V All Rev GLC2600 TC41 24V GLC2600T GLC2000 Series GLC2600 TC41 200V All Rev IT2400 TypeA IT2400 TC41 GP IT Series IT2400 TypeB IT2400 TC41 GLC B Related Screen Editor Software GP PRO PBIII for Windows Ver 5 0 or later When using this product with GLC2000 series or IT2400 Type B please use GP PRO PBIII C Package03 Service Pack 2 Ver 7 20 or later Memo AA Overview and Setup 1 1 Overview 1 2 Installation Procedure Yokogawa Electric FA M3 PLC Ladder Monitor Operation
22. red Device Monitor Exists Device Monitor files already exist in the project Press the Delete button to remove the files from the project Cancel Help Click Delete to delete the currently registered Device Monitor data Then select Screen Setup menu s Device Monitor and click Add to register the feature again B Registering the Global Window Select the GP Settings feature s Extended Settings tab and click Global Window The following Global Window Settings screen will appear Global Window Settings Iv Global window Ok Window Access Mode Cancel C Direct Registration don _ oF Indirect Data Format Binay C BCD window kaaa x Pos 320 Y Pos 248 z Enter the following settings ddi Global Window Settings Select Global Window Window Access Mode Select Indirect Data Format Select Binary Click OK to confirm these settings 2 3 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual 2 1 4 Project Transfer Next transfer the project to the GP unit For project transfer details GP PRO PB III for Windows Operation Manual Included with the screen editor software 2 1 5 Copy Boot File to a CF Card Insert a CF Card into your PC s CF Card reader and copy the Ladder Monitor boot file to the CF Card s root directory The boot file is located in GP PRO PB III for Windows screen editor software s PROTOCOL fol
23. via a 32 bit instruction results in an error 2 1 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual Display sample of SCALL function Display on Programming Software SCALLEIE Display on Ladder Monitor vaste mo reo oec rowel con Tw pom Tr SALL ec TRAGI Pit TJ ERE DCE RFSM ERI Heh gode nica gue HERREN peu Bm PRAH E ELF ce bc ink mm pam gau nia gt con EET Hie 10d 0127 AAA Fh FERE 8 YAFA 5 aia Be 7h ZELE 2 18 3 Errors 3 1 Error Messages 3 1 Yokogawa Electric FA M3 PLC Ladder Monitor Operation Manual 3 1 Error Messages The following table lists errors that can occur Message Possible PossibleCause Seo CF Card switch is OFF The lid of CF Card is open whether the lid of CF card is GE Cadisnopimstalisd The CF Card has not been inserted Check whether CF card is inserted into the GP unit s CF Card socket correctly Check whether the contents of CF CF card data is unusual card can be read correctly CF card is not formatted Check whether CF card is format ted CF Card Data Error Check whether a file required for a ladder monitor exists It checks whether CF card is inserted cor rectly Cannot read the file from CF Card Cannot read from CF Card CF card was extracted during read ing Cannot Write to file on the CF Card Check whether CF card is inserted CF card was extracted duri