Home
GEH-6514-615 - GE Digital Energy
Contents
1. Ta Services and Applications 14 e Installing the Software PMCS Read This Book First Add Remove Hardware Wizard Choose a Hardware Device Which hardware device do you want to troubleshoot The following hardware is already installed on your computer If you are having problems with one of these devices select the device and then click Next If vou are attempting to add a device and it is not shown below select Add a new device and then click Next Devices Default Monitor E Floppy disk drive E WDC wD200BB 75AUA1 ISAPNP Read Data Port l PCI standard host CPU bridge 88 Inteli 82815 Granhins Controller d lt Back Cancel Select the appropriate network adapter from the list and click Have Disk Follow the instructions provided on the screen to complete the network card installation For PMCS systems using one or more GE Multilin RS232 to RS485 converters or equivalent no additional drivers are required Ethernet PMCS Network Interfaces If you are using an Ethernet interface card to connect to the PMCS network through one or more Ethernet Gateways or directly to a network of Universal Relays EPM 9450s EPM 9650s Modbus TCP IP follow the manufacturer s installation instructions and be sure to install the provided Windows NT drivers using Control Panel gt Administrative Tools gt Computer Management gt System Information gt Components gt Network gt Ada
2. PMCS Read This Book First Installing the Software e 31 GE Power Management Control System Setup Setup Type Choose the setup type that best suits your needs PMCS PMCS with EPM 7700 Components Installshield 10 If you did not select PMCS with EPM7700 Components in the Setup Type dialog box Step 9 skip this step and proceed to Step 15 32 e Installing the Software PMCS Read This Book First If you are installing the EPM7700 Components select whether this is to be a Primary node installation or Secondary node installation You must install at least one Primary node on your PMCS network it is recommended that you install the Primary node at the same machine as the PMCS DDE Server for convenience in configuration Secondary nodes are akin to PMCS view nodes and may be installed on remote machines to access EPM7700 EPM 7600 or EPM 7500 data from the Primary node For additional details on Primary and Secondary nodes see the section on configuring EPM components later in this chapter GE Power Management Control System Setup x Select EPM7700 installation type Please select either Primary or Secondary Node installation You must install an EPM 7700 Primary Node in your PMCS network before installing any EPM 7700 Secondary Nodes PRIMARY Install an EPM7700 Primary Node C SECONDARY Install an EPM7700 Secondary Node InstallShield lt Back Cancel PMCS Read This Book First
3. Performance Response times e second or less to open an HMI screen e seconds update time to populate a screen per device per serial port Except for UR Device e 4to 7 second time delay to display event in PMCS Event Viewer e 1 second response time to make device change settings command coil not including device feedback e 1000 device events sec burst support Configuration 10 Getting Started PMCS Read This Book First Maximum 15 devices per serial port Device baud rates set to maximum Devices supporting 125 register block reads less than 2 Modbus communication errors timeouts Average CPU utilization lt 35 99 system uptime Where to Get Help Your PMCS CD ROM contains the full suite of PMCS 6 15 Technical Documentation in Adobe PDF format located in the CD drive gt Tech_Doc GE_CD directory These files require Adobe Acrobat Reader 3 0 or higher to view and print The PMCS installation wizard provides the option of running the Acrobat Reader 3 0 setup utility from the CD during software installation The installation wizard also creates a PMCS Online Manuals icon in both the GE PMCS folders in the Start menu and on the Desktop Clicking either of these icons will launch the Acrobat Reader and provide navigation tools for browsing all the available documentation If you prefer a bound set of printed manuals the complete set of PMCS 6 15 technical documentation is available for purchase by ordering c
4. D Setup exe RuninSeparate Memory Space Cancel Browse 2 The below screen is observed when Net is not installed on the machine where PMCS is being installed 24 e Installing the Software PMCS Read This Book First GE PMCS 6 15 Sz GE Multilin InstallShield Wizard E 3 tem PMCS 6 15 Setup is preparing the InstallShield Wizard which will E guide you through the program setup process Please wait Configuring Microsoft R NET Framework mm Cancel PMCS Read This Book First Installing the Software e 25 fig Microsoft NET Framework 1 1 Setup g p License Agreement Microsoft amp copy of this license is available for printing at http zo ricrosoft convfwlink LinkId 12283 SUPPLEMENTAL END USER a LICENSE AGREEMENT FOR MTC ROSORT SOFTWARE mi have read understood and agree to the terms of the B End User License Agreement and so signify by clicking agree and proceeding to use this product C agree do not agree Install InstallShield Wizard E PMCS 6 15 Setup is preparing the InstallShield Wizard which will ET guide you through the program setup process Please wait Configuring Microsoft R NET Framework 3 Click on I agree and click on Install button It will now install Net Framework on the machine where PMCS installation is started After the Net installation is completed below message box is displayed Click OK to continue 26 Installing th
5. RTU network to up to 247 devices Modbus RTU An industry standard nonproprietary communications protocol typically used in medium speed networks up to 38 4 kpbs on RS485 NetBEUI A network protocol usually used in small department size local area networks of to 200 clients NetDDE A version of Dynamic Data Exchange DDE that allows communications between applications running on different PCs over network connections NT Service A designated piece of software which runs in the background of Windows NT and can be set to automatically start when the machine is booted up For example the PMCS DDE Server can be set to operate as a Windows NT Service rather than a manually launched application Another advantage of NT Services is that they are persistent across multiple user logins and logouts that is PMCS DDE Server when operating as a Windows NT Service will not shut down when a user logs off ODBC Open Database Connectivity An inter application communication protocol required for certain PMCS client applications to share data Automatically installed and configured as part of the PMCS installation routine PMCS Power Management Control System GE s high performance power management system for Windows 2000 SP4 including open network protocols waveform capture and analysis event logging and several optional modules POWER LEADER The family of GE power management devices including meters relays trip units and softwa
6. and click Next 5 Enter your name your company name and the serial number located on the PMCS CD jewel case then click Next If you make an error in the serial number the installation routine will prompt you for a correct PMCS serial number 6 Choose either PMCS PMCS with EPM7700 Components or Custom installation PMCS or PMCS with EPM7700 Components installation will reinstall all components of the appropriate PMCS catalog number Select Custom if you wish to reinstall only selected PMCS software components 7 If your system includes the User Screen Configurator the GE Wizards must be re installed in your third party HMI application after upgrading See GEH 6513 User Screen Configurator and the HMI software documentation Configured application windows must be re associated with the newly installed wizards Open each application in the HMI application PMCS Read This Book First Installing the Software e 45 and double click on each wizard to re associate the application objects with the new wizards It is also advisable to update the tag counts and delete the unused tags See the generic HMI software s documentation for complete details 8 After upgrading launch the PMCS DDE Server The Server will convert your previous PMCS configuration to a PMCS 6 15 configuration Similarly when you launch the Event Logger application after an upgrade the Event Logger will convert your previous event configuration file to a PMCS 6 15 co
7. delay from 10000 to 30000 on the Advanced tab See second figure below for Advanced tab All other parameters may be left at their default values for most applications When you click OK in the Add Site dialog box Network Builder will inform you if there is additional information you must enter 58 e EPM Devices Special Considerations PMCS Read This Book First PRIMARY Add Ethernet Site x General Advanced Name PRIMARY Site1 Transmit Delay 100 milliseconds v Startup Connected Time Synchronization v Enabled for 3xxx devices Interval 3600 seconds v Enabled for 7xxx devices Interval 3600 seconds M Enabled for 3720 devices Interval 3600 seconds Use Defaults Cancel Help PRIMARY Add Ethernet Site x General Advanced Receive Timeout Er milliseconds Site Station Number Pad Byte Offline Timeout Period 30 seconds Pad Number Max Attempts Multiple 3 Online Priority Attempt Increment 3B Offline Priority 28 Offline Attempt Number a Connect Attempts INFINITE Connect Timeout 0 seconds v Continuous Attempts V Use Acknaks Diagnostics Service PRIMARY Sitel Use Defaults Cancel Help TL PMCS Read This Book First EPM Devices Special Considerations e 59 Adding Devices Meters To add a meter right click on the Ethernet site you want to add the meter to and select Insert Device from the pop up menu The Add Ethernet Device dialog box appears sh
8. e Compatible with industry standard third party SCADA platforms e Built in Modbus RTU network compatibility for an open network architecture and high speed communications e Built in Ethernet TCP IP network compatibility for very high speed communications and reduced wiring costs e Built in support for the comprehensive line of POWER LEADER power management devices as well as additional GE meters and relays Fanuc 90 30 90 70 and Micro 90 programmable logic controllers plus support for third party meters and relays e 3D virtual device interaction with accurately reproduced device look and feel e Improved waveform capture including extensive analysis tools e Comprehensive alarm and event reporting for immediate diagnosis of electrical system problems e Multiple View Node support for seamless access and sharing of power management data across your existing LAN e Configurable password protection and user activity logging for improved security and restriction of setup or control operations PMCS Read This Book First PMCS Read This Book First PMCS option modules are available to further increase productivity and reduce energy costs Your system may include one or more of the following modules e User Screen Configurator with tools to quickly create accurate intelligent floor plans one line diagrams and elevation views e System Test Simulator to design and test PMCS systems without connection to real networks or
9. features Internet Explorer version 4 0 or higher must be installed The latest version of Internet Explorer is available at www microsoft com Please note that the host PC requirements are directly tied to the complexity of your PMCS system The minimum requirements will suffice for a simple PMCS system However as the number and complexity of your power management device grows and you add more complex software requirements such as custom interfaces designed with third party HMI tools your PC requirements increase as well A faster processor and more memory provide better performance for your PMCS system Users of WonderWare InTouch should refer to the InTouch User s Manual for guidelines on the relationship between memory and the number of DDE tags supported PMCS 6 15 Envelope definition 1 Physical System e 75 power management devices IEDs 100 max e 1501 0 points through IEDs or PLCs e 64 ethernet serial communications ports e 2 Modbus Monitors maximum using standard Modbus Monitor Proxy 2 HMI Application Size e InTouch 9 5 no standalone 20 000 points tags in HMI database 30K Max 600 HMI alarms configured max 600 trended points 8 max per device HMI I O rates alarm rates and logging rates not to exceed 750 pts sec 150 HMI screens in InTouch 10 of tags connected to enterprise solution Maximum of one Viewer node 3 Special Application Issues e Noredundancy e Components to be run as NT services by default 4
10. license for use on another PMCS installation simply right click on any PMCS executable on your desktop and select unlicense PMCS Read This Book First The screen will request the eLicense Order ID to be entered 9 PMCS Unlicense ledronic License Distribution 9 PMCS Unlicense Successful e A screen will appear to indicate that you have successfully un elicensed and you may now take the eLicense Order ID for use on another PMCS installation Please note that you can not retrieve an eLicense for re use through the unlicense process past 3 years of initial Licensing Uninstalling PMCS All PMCS software is provided with an uninstall utility to fully remove PMCS components from your system Uninstalling PMCS will permanently delete any configuration information Note The Uninstaller may not delete some files such as error logs system logs and configuration records which are created after the PMCS installation is complete Since these files are not part of the initial installation they will not be removed by the Uninstaller and must be deleted manually PMCS Read This Book First Installing the Software e 43 If you are uninstalling EPM software components be aware that the Pegasys System Log Service does not properly unregister itself as an NT Service You will also be unable to delete some Pegasys Directories from your PC until the Pegasys System Log is stopped and uninstalled The following pro
11. name of the computer in the Name field Use the default settings on the Advanced tab Click OK then proceed to Adding Software Nodes below netconfig dat PEGASYS Network Builder File View Item Help ET md elie ded m1 ly e f rerum Add Workstation x G i Descriptio eneral Advanced Domain c Name PRIMARY System Cancel Help 2 Ready NM 2 56 EPM Devices Special Considerations PMCS Read This Book First Adding Software Nodes Software nodes identify the various software components in the network Stationless Secondary nodes although they are physically separate computers do not run a Communications Server and are therefore not considered Workstations by Network Builder Instead Stationless Secondary nodes appear in the network diagram as software nodes under the Primary Workstation Full Station Secondary nodes appear as Workstations because they do run an instance of the Communications Server Acknowledging the Add Workstation dialog brings up a message box asking if you want to set up the default software nodes choose Yes to display the software nodes dialog shown below Select only ION Designer Pegasys ION Link DDE Server and ION firmware upgrade utility as shown then click OK to proceed S netconfig dat PEGASYS Network Builder File View ltem Help sjaje System Ready PMCS Read This Book First Sa PR
12. one from the existing folders list Click Next to continue Program Folders GE PMCS Existing Folders InstallShield lt Back Cancel 38 e Installing the Software PMCS Read This Book First 17 GE Power Management Control System Setup Selected The Selected Components screen offers you the opportunity to verify the installation settings before any files are copied to your hard drive Confirm that the installation settings are correct then click Next The installation program copies the appropriate files to your hard drive x Components You have selected the following PMCS 6 15 components for installation Press Next to proceed with the installation or Back to change selections Current Settings PMCS Configurator Waveform Viewer Modbus EIND Server Waveform Capture Client Waveform Server Wizards 7700 System Components gt InstallShield TCP IP DDE OPC Server lt Back Cancel If you have selected the EPM7700 System Components either manually when performing a Custom install or automatically when PMCS with EPM7700 Components install is selected the installer will check your system for a copy of Microsoft Internet Explorer version 3 02 or higher This is because the EPM software components use html format help files which require Internet Explorer to view If Internet Explorer is not found the following dialog box appears Information
13. this dialog information i Setup has successfully completed the installation Now close all other applications and restart the system Restart is required to enable the PMCS applications start up normally and automatically Be sure to view the ReadMe file to check any late breaking information useful to the configuration or operation of your PMCS system NOTE Your computer MUST be restarted after installing PMCS software This step is critical to proper operation of the software as it enables the following to happen e The operating system will register the new software components e Jnitial network configurations for EPM7700 EPM 7600 and EPM7500 devices will be created e It will startup the main Application of the PMCS system which is EnerVista Status Tool which enables the use of all the other PMCS components PMCS Read This Book First Installing the Software e 41 42 Installing the Software After PMCS IIS Setting up PMCS Server For any PMCS remote viewer system to connect to the PMCS server the prerequisite is to have IIS installed on the PC first then Net Framework installed on the same PC and after that installation of PMCS But if PMCS is installed before IIS is installed on any PC then please follow the steps mentioned in the below For Windows 2000 SP4 Windows XP SP2 OS 1 Install PMCS with server licences 2 Install IIS 3 In the PMCS CD there is dependencies folder 3a Double click on the de
14. x D suitable version of Microsoft Internet Explorer was not found on this computer You will not be able to use EPM7700 component html help files until Internet Explorer version 3 02 version 4 0 recommended is installed on your system PMCS Read This Book First If you wish to view the EPM software help files you should separately install Microsoft Internet Explorer version 3 02 or higher To take advantage of all available help system features Internet Explorer version 4 0 or higher is required Internet Explorer is not included as part of PMCS You may obtain the latest version of Internet Explorer by downloading it from www microsoft com Installing the Software e 39 18 After completing the selected PMCS installation the installation program checks the host PC for an older version of the POWER LEADER Modbus Monitor Proxy software If the installer locates the Proxy software it prompts you to update the Proxy to the PCMS 6 x compatible version before finishing the PMCS installation routine If your system does not use POWER LEADER Modbus Monitor devices or does not have the Monitor Proxy software installed the PMCS installer will skip this step Information x 3 Setup has detected an older version of the Modbus Monitor Proxy and will now run the Proxy Setup program 19 At this point the installation program copies the appropriate files to your hard drive 20 After the Setup program finishes installi
15. xxx 254 and working down Set RAS to start automatically and set access to entire network if available 54 e EPM Devices Special Considerations PMCS Read This Book First Configuring the EPM Device Network The PMCS installation routine described earlier in this manual creates initial workstation and software node entries in the EPM network configuration file After EPM software components are installed the next step is to add Ethernet sites and devices to the PMCS power monitoring network using Network Builder software Running Network Builder Network Builder software presents your EPM power monitoring network graphically showing the installed components in a hierarchical tree Network Builder allows you to edit the Network Configuration file the file that identifies every node in the EPM power monitoring network The first step is to run Network Builder from the Start Menu Programs gt Power Measurement Ltd gt Utilities gt Network Builder The following figure shows how Network Builder displays a system comprised of the basic EPM software components a single EPM7700 meter a Primary Node and a Stationless Secondary node also called a view node V netconfig dat PEGASYS Network Builder Mi EG z kstation the network f e e i Workstation the network name o the Primary Node computer running the Communications Server and GE Software nodes Stationless Secondary nodes appear here DDE
16. 5 Building the Power Monitoring Network in Netbuilder eese 56 Adding Devices Meters esee terere tret ree ee eed a eise eue na denen 60 Saving and Exiting 3 2i oom ten PROBES PORE ERR Ete bets 60 Index 62 PMCS Read This Book First Contents e iii Introduction Welcome Hello and welcome to the POWER LEADER Power Management Control System PMCS You are about to begin using your computer in an exciting new way as a tool to help you increase productivity while reducing downtime and energy costs This book is for anyone getting started with PMCS It contains the information you need to install and begin using PMCS effectively e Chapter 2 Getting Started explains the terminology of power management systems describes each of your PMCS items outlines the minimum system requirements and lists methods of getting GE Technical Support e Chapter 3 Installing the Software explains how to prepare your system and install all of the PMCS software Any special installation steps are outlined for each software module e Chapter 4 Configuring the Software describes how to efficiently configure PMCS to get up and running in the shortest time e Chapter 5 EPM Devices Special Considerations details the additional configuration required to use EPM7700 EPM 7600 and EPM 7500 meters in a PMCS network How to Use this Book PMCS Read This Book First You will find this book easy to use if
17. Corporation US Pat Nos 5 768 148 5 764 155 5 862 391 This page left blank intentionally PMCS Read This Book First TBack to Main PageT e i Back to Main Page Contents Introduction 1 Welcome shoot mel ha nO on OO eg onn eoe denen inae ett 1 Howto Use this Book ose pe re Re eie a ee ERI UE events 1 About Intouch PMCS Version 6 15 iei tee eite e aote eden ta ne ese eren deeds 2 Performance o ea dte tendente ce t etn B D bee d eee 2 Features ote ee A e Sie A ol ea Rl ele 2 Supported D ViCE S site eR oe RET a eo e RUE 4 Getting Started 7 First Steps ns A icin rh e c d n e ete tom rev e e DPA E eo aes 7 Understanding Terminology eee ener nennen rennen 7 System Requirements doeet eet P Hes 9 PMCS 6 15 Envelope definition sese 10 Where to Get Help iuis eee eve eor eite etes 11 What S MEX coir iioc et ERE RE REPE EE EO dier een irictes 11 Installing the Software 13 Computer Preparation 2 o one tet eR ptite teur ete menit 13 When Installing On Windows 2003 Server sese 16 Installing Wonderware InTouch eeeeeeeeeeeeeeeenenetne nennen 18 Installing Additional Software eese rennen 19 Installing the EPM Software Components seen 19 Installing the PMCS softwares 5 5 52 ciae a o D REO Pc tse 20 eLicensimg PMOS SoftWare oie et etes Ee oos te teen liess tete i ien 20 Host PC Installation ni
18. GE MULTILIN PMCS 6 15 Read This Book F irst Installation Guide GEH 6514 GE Power Management Control System Notice The information contained in this document is subject to change without notice GE makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose GE shall not be liable for errors contained herein or incidental consequential damages in connection with the furnishing performance or use of this material This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied or otherwise reproduced without consent of GE Copyright 2000 2006 by GE Published in a limited copyright sense and all rights including trade secrets are reserved Document Edition First 5 96 Second 9 96 Third 5 97 Fourth 01 98 Fifth 06 98 Sixth 02 99 Seventh 7 09 Eighth 11 99 Ninth 03 00 Tenth 10 00 Eleventh 02 01 Twelfth 06 01 Thirteenth 09 01 Fourteenth 12 01 Fifteenth 03 02 Sixteenth 05 05 Seventeenth 10 06 The following are products of General Electric Company POWER LEADER Meter 239 Motor Protection Relay GE Fanuc Series 90 30 PLC POWER LEADER Modbus 269 Plus Motor Management Relay GE Fanuc Series 90 70 PLC Monitor POWER LEADER Electronic Power Meter 369 Motor Management Relay Power Quality Meter PQM Spectra MicroVersaTrip E
19. Gateway Server For Comm Server configuration instructions refer to EPM Software Components Configuration below For GE 7700 Gateway Server configuration instructions refer to DEH 40035 the GE 7700 Gateway Server User s Guide 3 Configure the user interface If your system was provided with a generic HMI software application either load or create the custom HMI using the User Screen Configurator wizards if appropriate see GEH 6513 User Screen Configurator or refer to the HMI software s documentation 4 Configure the applications As appropriate configure the following application modules referring to the instruction manuals provided e Event Logger GEH 6512 e Waveform Capture GEH 6511 5 Test the applications Test the functioning of all applications to ensure proper Host PC operation Do not proceed to step 6 until you are sure the Host PC operates as expected 6 Set up NetDDE If your system has one or more View Nodes set up NetDDE shares and trusts in the Host PC following the procedures in GEH 6510 Network amp Device Configurator 7 Set up NetDDE If your system uses the PMCS Waveform Capture client and you intend to access waveform data from View Nodes set up NetDDE shares and trusts for the PMCS Waveform Server following the procedures in GEH 6511 PMCS Waveform Capture Module View Node Configuration 1 Configure the user interface Load the custom HMI Refer to the HMI software s documentation as ap
20. IMARY NODE Software Nodes PEGASYS Vista MV PEGASYS ION Designer Iv ION Firmware Upgrade Utility PEGASYS Alarm Printer PEGASYS Test Utility Cancel PEGASYS Log Server IV PEGASYS ION Link DDE Server Property Vaue Description DomainNumber 1 Domain component o EPM Devices Special Considerations e 57 Adding an Ethernet Site An Ethernet site defines the network connection between the devices and the Workstation s You add Ethernet sites to Workstations then add devices to the sites To add a new Ethernet site right click a Workstation name and choose Insert Ethernet site from the pop up menu attach it to the current Workstation Click OK to continue netconfig dat PEGASYS Network Builder File View ltem Help We sl slxlel Diagnostic Gateway site Station cc Modem site Serial site Software node Workstation Cancel hr Help Attach to PRIMARY Y n NUM Z An Add Ethernet Site dialog box shown below appears Set the following communications parameters for the site e Enter the Transmit delay setting in milliseconds This setting determines the level of traffic on the network If the PMCS system is the sole user of the network set this value to 5 or less to maximize performance Increase the transmit delay in situations where the network is shared with other users such as on a corporate LAN e Change the RX timeout
21. Installing the Software e 33 11 If you did not select PMCS with EPM7700 Components in the Setup Type dialog box Step 9 or if you selected Primary Node Installation in Step 10 skip this step and proceed to Step 15 If you selected Secondary Node installation in Step 9 the following dialog box appears prompting you to select either Full Station or Stationless node installation If you are installing software on a computer that will service EPM7700 EPM 7600 or EPM 7500 IEDs directly choose Full Station If you are installing software on a computer that will not be connected to IEDs but will be used to access data from other network workstations choose Stationless For more details on EPM Device network configuration refer to the EPM Device Special Considerations section later in this manual or to DEH 40035 the GE 7700 Gateway User s Guide xi GE Power Management Control System Setup Select EPM7700 view node type Select Full Station for workstations that will connect directly to field devices For workstations that do not connect directly to IEDs select Stationless node installation Install a Full Station Secondary Node C Install a Stationless Secondary Node InstallShield lt Back Cancel 34 e Installing the Software PMCS Read This Book First 12 If you did not select PMCS with EPM7700 Components in the Setup Type dialog box Step 9 or if you selected Pri
22. PM 7600 Electronic Power Meter Enhanced MicroVersaTrip C Enhanced MicroVersaTrip D MDP Overcurrent Relay SR750 SR760 Feeder Management Relay Universal Relay GE Zenith MX200 Micro Processor Contl EPM5350P DMMS350 EPM9650Q Nexus1252 Remote RTD Entellisys Low VoltageSwitchgear EPM 1000 Sub Meter GE Zenith MX250 UPS SR469 Motor Management Relay EPM 7500 Electronic Power Meter SR489 Generator Management Relay 565 Feeder Management Relay 735 Feeder Relay SR745 Transformer Management Relay EPM7430D EPM7450D Futura GE Zenith Generator PLC Series90 70 EPMS5000P DMWH300 EPM8000 POMII Motor Manager III MMIII MIFII Feeder Management Relay EPM 4000 Sub Meter GE Zenith MX150 FIRETRACER EPM 7300 Electronic Power Meter EPM 7330 Electronic Power Meter EPM 7700 Electronic Power Meter EPM 3710 Electronic Power Meter EPM 3720 Electronic Power Meter Spectra Electronic Control Module Motor Manager II MMII EPM5300P EPM5200P EPM9450Q Nexus1250 F650 Bay Controller 737 Feeder Relay EPM 2000 Digital Power Meter EPM 6000 Multifunction Electricity Meter SMR2 VERSAMAX GE MULTILIN PMCS 6 15 Read This Book F irst MPRO Microsoft Microsoft Excel and Microsoft PowerPoint are registered trademarks and Windows 2000 SP4 is a trademark of Microsoft Corporation Wonderware is a registered trademark of WonderWare Corporation Wonderware InTouch and NetDDE are trademarks of WonderWare
23. SRV INSTALL DDESRV REM OTE DESIGNER INSTALL Ethernet Site Defines the DESIGNER REMOTE Ethernet connection between UPGRADE INSTALL the PMCS system and the UPGRADE REMOTE m INSTALL Site1 INSTALL ETHER220 Device Name s of attached device s PMCS Read This Book First EPM Devices Special Considerations e 55 Building the Power Monitoring Network in Netbuilder When Network Builder is running you can begin configuring your EPM system by adding a site to the workstation then adding devices to the site For larger systems multiple sites are added one for each network of devices monitored NOTE The PMCS installation wizard creates initial entries for the workstation and software nodes If you do not need to make changes to the information provided during installation skip this section and begin with the section title Adding an Ethernet Site Adding a Workstation When you use the PMCS installation wizard to install a Primary node or Full Station Secondary node it creates a Workstation in the Network Configuration for you Stationless Secondary nodes do not appear in the network configuration as workstations but as software nodes under the Primary workstation See the section on software nodes for more information To add a new workstation right click System and choose Insert Workstation from the pop up menu The System Add Workstation dialog box appears as shown below Type the network
24. another computer Select Launch from your License Installation Success Screen to continue installing PMCS PMCS Read This Book First Installing the Software e 21 22 Installing the Software Host PC Installation Every PMCS system requires one Host PC that is directly connected to the PMCS network and communicates with the power management devices The Host PC is also typically used to view and analyze data If you are installing multiple PMCS catalog numbers on the Host PC you will need the CD and serial number from each package Follow the Installation Steps section below If the Host PC will be providing data to View Nodes be sure to refer to GEH 6510 Network and Device Configurator to configure NetDDE for operation with the View Node PCs View Node Installation PMCS supports optional View Nodes which interact with the power management network through NetDDE links to the Host PC View Nodes are not directly connected to the PMCS network but are connected via LAN to the Host PC View Nodes are not mandatory in a PMCS system because the data is available for display and analysis at the Host PC When installing PMCS View Nodes be sure to use only an appropriate catalog number for the installation Do not install any other PMCS software on a PMCS View Node NOTE The EPM software differs from the standard PMCS usage of View Nodes Refer to the section titled EPM Devices Special Considerations for more details on EPM Workstatio
25. ase wait while Windows configures Microsoft SQL Server Desktop Engine Gathering required information COCCI Cane After the above window closes Restart the system and follow step 1 to continue with PMCS6 15 installation From here on the below steps follows 8 At the Choose Destination Location dialog specify a drive on which to install PMCS Default is C Click Next to continue 30 e Installing the Software PMCS Read This Book First GE Power Management Control System Setup Choose Destination Drive Setup will install PMCS on the following drive After selecting an appropriate drive letter click Next InstallShield Back Cancel 9 At the Setup Type screen select either a Custom installation standard PMCS installation or PMCS with EPM7700 Components PMCS installation is recommended and will install all components for the PMCS catalog number you entered in the User Information screen Select PMCS with EPM7700 Components if you will be installing EPM7700 EPM 7600 or EPM 7500 devices in your network Select Custom if you wish to select specific PMCS software components to install Click Next to continue NOTE This dialog does not appear for certain license keys of PMCS they are PMCS View node license where Remote Viewer gets installed for low cost server catalog for SCADA catalog for Only Serves catalog After step 8 the step 15 follows Otherwise the below steps are followed
26. atalog number PLSOTECHGOI The GE ED amp C Resolution Center is available at 1 888 GE RESOLV to answer your questions about installing or using PMCS Please have your product serial number s ready when calling Also PMCS technical notes are available on the Internet at http www ge com industrialsystems pmsys Technote noteidx htm What s next The following chapters discuss the details of installing and getting quick results from your new PMCS software Set aside at least an hour and be sure to follow the procedures carefully to guarantee correct installation of your PMCS software PMCS Read This Book First Getting Started e 11 Installing the Software Computer Preparation PMCS must be installed on a PC running Windows 2000 SP4 This host PC must be dedicated to the PMCS system Performance and data integrity cannot be predicted unless the PC is configured solely for the purpose of running PMCS The Windows 2000 SP4 System control panel offers a Performance tab that allows you to boost performance for the applications s shown below The Virtual Memory setting may be left at the Windows 2000 SP4 defaults Make sure your system meets these requirements before proceeding with the remaining installation steps PMCS will not run correctly unless these requirements are satisfied System Properties PMCS Read This Book First Installing the Software e 13 RS485 PMCS Network Interfaces If you are using an RS485 interfac
27. because of the installation code migration from old version of Install shield professional to new version of install shield Developer Aj GE Power Management Control System Setup GE Power Management Control System Setup InstallShield Wizard Completed The wizard was interrupted before GE PMCS 6 15 could be completely installed Internal Failure L x Error Number 0x80040707 Description To install this program at a Ca f Ges Aso e ORAMA s deeem To d OMS som Follow the procedure below to install each PMCS catalog number Be sure the catalog numbers you are installing are appropriate for the destination PC Host PC or View Node Close any open applications before installation Insert the PMCS Installation CD into the CD ROM drive If CD Auto Start is enabled the PMCS installation routine will launch automatically In this case skip steps 2 and 3 and proceed directly to step 4 Click the Start button from the Windows 2000 SP4 Task Bar and select Run PMCS Read This Book First Installing the Software e 23 New Office Document Open Office Document Sametime Connect Windows Update SAMAY 3 0 Programs gt Documents gt Settings gt Search p Click here Help Run Shut Down 1 In the Run dialog box enter X setup where X is the appropriate CD ROM drive designation Run EEG Type the name of a program folder or document and Windows will open it for you Open
28. by default v EPM7700 Components IV Wizards Intouch or Cimplicity v MODBUS EIND Server lt Back Cancel 15 If you are installing the GE PMCS Wizards and WonderWare InTouch 9 5 or later is not installed the following dialog appears prompting you to select the destination directory to install the Wizards in The other dialog informing that Intouch is not present also pops up on a machine where Intouch is not installed but PMCS is started for installation Click Yes and continue with the Intouch Directory dialog This situation should be seen only during an upgrade operation InTouch Not Found E x 9 Setup has determined that InTouch is not installed on this system Intouch should be installed prior to installing PMCS Do you want to continue setup Installing the Software e 37 GE Power Management Control System Setup E E xl InTouch Directory Please specify the directory where InT ouch is installed The GE PMCS wizards will be copied to this directory Destination Folder C Program Files F actorySuiteXInT ouch Browse InstallShield 16 Select the Program Folder for PMCS installation It is recommended that the default Program Folder be chosen Click Next to continue GE Power Management Control System Setup Select Program Folder Please select a program folder Setup will add program icons to the Program Folder listed below You may type a new folder name or select
29. cedure will allow you to manually uninstall this component the remaining PMCS software can then be uninstalled in the usual manner Uninstalling the Pegasys System Log Service 1 Open a Command Prompt window 2 Make the C drive the current directory assuming your Windows system files reside on the C drive 3 Type slservice e EXACTLY as shown and hit enter 4 If the Pegasys System Log Service was installed and running you will receive the message Pegasys System Log Service stopped If you do not receive this message the Log Service was not installed on your system Exit the command prompt and continue uninstalling PMCS 5 If you received the correct message in step 4 uninstall the service Type slservice u EXACTLY as shown and hit enter A message appears indicating Pegasys System Log Service uninstalled Exit the command prompt and continue uninstalling PMCS Reinstallation Steps Follow the procedure below to reinstall your PMCS software 1 If your system includes the User Screen Configurator uninstall the GE Wizards from any third party HMI tools 2 Close any open applications 3 Insert the PMCS Version 6 15 CD into the CD ROM drive 4 From Start menu select Run and enter X setup where X is the appropriate CD ROM drive designation 5 Read the general information and disclaimers shown on the screen and click Next 6 Enter your name your company name and the serial number located on t
30. completed Your PMCS software is provided on a CD ROM The diagram below depicts the relationship of the Host PC and any optional View Nodes in your system Follow the specific instructions below for software installation on Host PCs and View Nodes PMCS Network s eLicensing PMCS software General Electric Industrial Systems has added security technology that requires your PMCS software to be licensed in order to run A separate license is required for each computer that will receive PMCS Each eLicense Order ID that is sent with your order corresponds to one license You license your software as part of the automated PMCS installation process When you launch the installation process the first screen that will appear will be your eLicense Option screen see below These screens allow you to either trial or fully license your PMCS software 720 Hours 30 Day Trial You have the option to Trial PMCS for 720 Hours 30 days through the 720 Hours Trial selection on this screen All functionality of PMCS is available to trial users and all configurations made for the software will be maintained from one use to the next A single trial is registered to each PC and may not be uninstalled and re installed for another trial 20 Installing the Software PMCS Read This Book First Licensing via the Web I xi r ita a3 Costas lila a software package that turns a desktop computer into a virtual window for tracking and controllin
31. devices Introduction e 3 Supported Devices PMCS 6 15 supports the following devices Firmware revisions other than those listed may not be compatible with PMCS Contact your GE Sales Representative or the GE Resolution Center at 1 888 GE RESOLV for more information IED Versions IED Product Versions Product Supported Supported icroVersa Trip icroVersa Trip C Note SON aA Te Ax UR has been categorized into three different Device Types 3x10 4 5x 4x 3 4 IAM UR rts 2 6x to 4 6 oe AEMPER supports 2 6x to 4 6x 745 UR480 supports 4 8x UR490 supports 4 9x and 5 0x 4 N 6x Ox 3x Ox Ml Mrz po 2 6x to 5 0x 4 4x to 5 0x 2 6x to 5 0x 2 6x to 5 0x po L60 4 e Introduction PMCS Read This Book First This page left blank intentionally PMCS Read This Book First Introduction e 5 Getting Started First Steps If you are already familiar with PMCS simply review the system requirements and skip ahead to Chapter 3 Getting started with POWER LEADER PMCS is easy This chapter explains power management and leads you through the steps to take prior to installing your PMCS software If you need help with your PMCS system the GE Technical Support telephone number is given at the end of this chapter Understanding Terminology Power management system terminology can be intimidating to new PMCS users The list below defines many of the important t
32. duct serial number User Name E your name here Company Name E your company here Serial Number your serial number here InstallShield me 6 If IIS is not installed in the Machine for the licenses it is required Below message pops up Click ok to continue without IIS or click cancel to abort PMCS installation install IIS and start PMCS setup again PMCS 6 15 IIS Information EE xi This installation of PMCS needs IIS to be present on this machine For any PMCS Remote Viewer Operation IIS is not Installed in this machine now Click cancel install IIS and start PMCS installation again to enable Remote Viewer Operation Click ok to continue with the installation 1 Cancel PMCS Read This Book First 7 If MSDE in installed in the system before PMCS 6 15 installation started then the installation proceeds with the below steps from 4 Otherwise The following message box appears click ok button Installing the Software e 29 x Microsoft SQL Server Desktop Engine MSDE 2000 setup starts and PMCS setup will exit now After MSDE installation it may ask For restart of the Computer Please do not restart the Computer Run PMCS Setup again to continue with PMCS installation The following installer will run and MSDE gets installed Windows Installer f Preparing to install Cancel This window appears when MSDE is getting installed Microsoft SOL Server Desktop Engine L3 Ple
33. e Software PMCS Read This Book First GE PMCS jie Microsoft NET Framework 1 1 Setup S7 GE Multilin InstallShield Wizard PMCS rege e dale E hl EY guide you through the program setup process Please Configuring Microsoft R NET Framework Cancel 4 The GE PMCS 6 15 Setup Welcome screen appears as shown below PMCS Read This Book First Installing the Software e 27 GE Power Management Control System Setup X Welcome to the InstallShield Wizard for GE PMCS 6 15 The InstallShield Wizard will install GE PMCS 6 15 on your computer To continue click Next DUET Cerca When you select the Next button in the Welcome screen the PMCS 6 15 license agreement screen is shown Please take a moment to read over the license agreement and then click Next 28 Installing the Software PMCS Read This Book First 5 At the User Information screen shown below enter your name your company name and the serial number for the PMCS component you are installing Serial numbers for PMCS components are located on the PMCS CD ROM jewel case If you make an error in the serial number the installation routine will prompt you for a correct PMCS serial number When you have completed the registration information click Next GE Power Management Control System Setup j E 1 Customer Information Please enter your information Please enter your name the name of the company for which you work and the pro
34. e card to connect to the PMCS network install the card following the manufacturer s installation instructions Be sure to install any Windows NT drivers provided by the interface card vendor Typically drivers are installed at Control Panel gt Network gt Adapters gt Add Adapter by following the instructions You may be prompted to insert the manufacturer s disk into the A drive ini x action vew e gt Om E 9 e M z GIA6FS56A Tree m Computer E Saite Local Disk drives faj Event Viewer 1 B Display adapters H i7 System Inf ti Floppy disk controllers amp irata cni Alerts SUP Floppy disk drives gl shared Folders i IDE ATAJATAPI controllers gi Keyboards E Shares 5 T i Sasons Mice and other pointing devices Open Files Monitors Z Device Manager JP Network canal paassa s 3 P Local Users and Groups 3Com 3C920 Integrated Fast Ethernet Controller 3C905C TX Compatible i ET Storage 29 Other devices f PCI Device Disk Management Y Ports COM amp LPT Disk Defragmenter s Logical Drives qp Sound video and game controllers e Removable Storage ep System devices 9 Universal Serial Bus controllers
35. erations e 61 Index A O alarm 2 option modules 3 D P DDE Server 52 PEGASYS nodes 51 E Performance 2 Ethernet 2 7 8 15 16 47 49 S event 2 servers F DDE 52 Fanuc 2 T First Steps 7 TCP IP 2 7 8 9 15 49 M Technical Support 1 7 11 Terminology 7 minimum system requirements 1 Modbus Monitor Proxy 39 U Modbus RTU 2 7 8 47 User Screen Configurator 3 9 43 44 49 W NetBuilder 50 Network Builder 50 waveform capture 2 Windows NT 8 15 20 62 e Index PMCS Read This Book First GE MULTILIN General Electric Company 215 Anderson Avenue Markham ON L6E 1B3 CANADA USA amp Canada 1 800 547 8629 Global 905 294 6222 Fax 905 201 2098 Email multilin tech indsys ge com lt mailto multilin tech indsys ge com gt GEH 6514 R15 03 02 2000 2005 General Electric Company
36. erms and acronyms used in this guide and other PMCS manuals Refer back to this list as new terms are presented later Baud rate A measurement of a communication channel s signaling rate or information carrying capacity Communicating devices typically have configurable baud rates to provide compatibility with various speed communication networks Higher baud rates generally provide faster data refresh times Commnet A GE ED amp C standard for device communications that specifies the communication protocol and the communication network Communication network A physical standard for wiring and interconnection of communicating devices A communication network standard usually includes specifications of voltages maximum cable run lengths shielding termination and cable requirements RS485 and Ethernet are examples of communication network standards Communication protocol A language or convention used for reliable transmission and reception of binary data A communication protocol is often independent of the physical method or network used for transmission Modbus RTU and TCP IP are examples of communication protocol standards DDE Server A software application that typically runs in the background gathering information from the network and providing the information in DDE format for use by one or more applications The PMCS DDE Server is included PMCS Read This Book First Getting Started 7 in the PMCS Network amp Device Conf
37. fere 10 47 28 201 Plating Meter maam 1 8 wis 10 47 28 201 2 66 PLEPM Officel Meter onam gt Wm e onewe Hogan 2 o M Feederl Rey onam i a ems E5se onam i oam m Pe Breaker Dogma e m wr offce reater View Node You should configure View Nodes after you have configured and tested the Host PC to ensure all functions are operating View Nodes require a copy of the network architecture list used above Refer to GEH 6510 Network and Device Configurator for complete configuration instructions PMCS Read This Book First Configuring the Software e 49 50 e Configuring the Software Configuration Procedure Follow the procedure below to efficiently configure your system and minimize your time to startup Host PC Configuration 1 Configure the DDE Server Your Host PC will likely have two versions of the DDE Server installed RS485 Modbus and Ethernet TCP IP Configure only the server appropriate for your PMCS network interface GE32MODB or GE32ENET See GEH 6510 Network and Device Configurator for complete details 2 EPM7700 EPM 7600 and EPM 7500 users only all others proceed to step 3 Configure the Communications Server and GE 7700 Gateway Server If you installed the EPM software options and you are going to use EPM7700 EPM 7600 or EPM 7500 devices in your PMCS network you will need to configure both the Communications Server and the GE 7700
38. g facility power With just a few clicks of a mouse you can gain real time access to the family of POWER LEADER devices and even to third party devices or systems With PMCS s powerful analytical tools you can perform advanced power quality analysis monitor energy consumption even manage loads It s all available through sophisticated graphics and a highly intuitive interface For Assistance Please Call nnn Cra Pent ol Powered by C license SYSTEM Hours left 720 Choose the Web License option if you have a working internet connection on your PMCS computer This option will automatically connect you to General Electric Industrial Systems eLicense distribution system Once connected an automated process will retrieve your unique PMCS eLicense key Selecting the Web License option from the License Option brings you to the Web License Screen This screen requires you to enter your eLicense Order ID This information is contained on the Order Confirmation Sheet that accompanied your PMCS software or it can be obtained from your Purchase Confirmation e mail Enter the Order ID and click on Get License to initiate the Web connection to General Electric Industrial Systems eLicense distribution system Similar to the trial each eLicense is registered to the computer in which case the eLicense Order ID can only be used for one computer The software must be unlicensed to be re licensed with the same eLicense Order ID on
39. guration for running PMCS Version 6 15 Note that regardless of configuration the PC system must be Windows NT certified according to the Windows 2000 with Service Pack 4 Hardware Compatibility List available from Microsoft www microsoft com In addition to the requirements described below setting up PMCS and EPM 7700 workstations will require Windows NT Administrator level authority privileges Recommended 1GHz or greater single processor Dell OptiP lex Windows 2000 SP 4 Professional Windows XP SP2 Professional Wonderware Intouch 9 5 512MB or greater RAM 512K cache 30GB or greater AT 100 hard drive 10 10 32 CDRW not operating burning CDs while application is running 2 10 BaseT Ethernet Cards static IP addresses only no DHCP support 1 parallel port printer 1 analog phone modem no Winmodems Internet Services Manager IIS Net Framework 1 1 4322 if not installed PMCS setup will install this component Additional hard disk space is recommended for increased storage of log and trend data Also recommended are an uninterruptible power supply UPS 17 or larger monitor tape drive or other backup mechanism and if Remote Access technical support is desired a 28 8 Kbps or faster modem PMCS Read This Book First Getting Started 9 Microsoft Internet Explorer 3 02 or later is required to run the EPM7700 component help system To take advantage of all available html help
40. he PMCS CD jewel case then click Next If you make an error in the serial number the installation routine will prompt you for a correct PMCS serial number 7 Choose the installation type either PMCS PMCS with EPM7700 Components or Custom installation PMCS or PMCS with EPM7700 Components installation will reinstall all components of the appropriate PMCS catalog number Select Custom if you wish to reinstall only selected PMCS software components 8 This item applies to reinstallation of the User Screen Configurator The GE Wizards must be re installed in your third party HMI software See GEH 6513 User Screen Configurator for details Configured application windows must be re associated with the newly installed wizards Open each 44 e Installing the Software PMCS Read This Book First application in your HMI program and double click on each wizard to re associate the application objects with the new wizards It is also advisable to update the tag counts and delete the unused tags See the documentation which accompanied your third party HMI software for complete details Upgrading from previous versions to PMCS 6 15 PMCS 6 15 provides an easy to use automatic upgrade path from previous versions of PMCS The software installer examines your hard drive and if it locates any previous version of PMCS it makes appropriate decisions on upgrading each component Follow the procedure below to upgrade your currently installed PMCS versi
41. igurator and comes in versions optimized for Ethernet TCP IP or RS485 Modbus RTU networks DDE Dynamic Data Exchange A Microsoft Windows standard for efficient sharing of data between applications on the same PC See also NetDDE Ethernet Gateway A POWER LEADER device used to connect four RS485 Modbus RTU networks to an Ethernet TCP IP network The Gateway increases performance of a PMCS system through multiple Modbus networks and reduces overall wiring costs through reuse of existing Ethernet LAN wiring Ethernet An industry standard communication network commonly used for local area networks LANs of PCs Ethernet PMCS systems provide very high speed reliable communications at 10 MBaud Event Logger A standard PMCS application that efficiently analyzes sorts and logs unusual system behavior such as circuit breaker trips undervoltages and overcurrents Extensive data logging capabilities make it a useful tool for analyzing and predicting system maintenance patterns Host PC The PC running the PMCS DDE Server is referred to as the Host PC All other PCs running PMCS client programs are referred to as View Nodes or networked PCs Modbus Concentrator A POWER LEADER device used to connect eight commnet networks to an RS485 Modbus RTU network The Concentrator provides full compatibility between the PMCS software and the extensive line of POWER LEADER devices with commnet communications as well as simple expansion of a RS485 Modbus
42. in te ether a Re e e gene ae 22 View Node Installation 4 2 2 enm e e em ent t ege Eras 22 PMCS Installation Steps essere enne nennen nennen enne 22 After PMCS IIS Setting up PMCS Server sese 42 Un e heensmeg PMES nierien er edet e i ei reed ven 42 Uninstalline PMCS 0 iei tee d oe i t ette 43 Reinstall tion Steps erro ete tto eoa tO rete e oe ESSE 44 Upgrading from previous versions to PMCS 6 15 sesssseeeeee 45 ii e TBack to Main PageT PMCS Read This Book First Installation of PMCS 6 15 over existing MSDE eene 46 Configuring the Software 48 Organize Your Information aiae f gebe ad e bi eed 48 Configuration Proc dure me Reto i tete e utente eene 50 EPM Devices Special Considerations 52 Introduction pansies sot onmino Om Ea E bee pP Dh a echa 52 EPM S ftw re Components 5 22 tr pep er OP Te LEO PET EE 52 Network Builder Building the Network Configuration File 53 ION Designer Programming Devices and Software Nodes sess 53 Communications Server System Communications eene 53 ION LINK DDE Server Communication with Windows Applications 53 Workstation Configuration Guidelines eese eene enne rene 54 Configuring the EPM Device Network esee 55 Running Network Builder eese enne 5
43. ing MSAFD Tcpip TCP IP False True True MSAFD Tcpip UDP IP True False False RSVP UDP Service Provider True False False RSVP TCP Service Provider False True True Local Area Network LAN Interfaces PMCS supports multiple View Nodes through NetDDE links over a local area network Thus in addition to the PMCS network interface the Host PC may also have a LAN interface A Host PC with an Ethernet PMCS network interface may use either the same Ethernet card as the LAN interface or a separate LAN interface card A Host PC with an RS485 PMCS network interface requires an additional LAN interface card to support View Nodes Typical LAN interface cards include Ethernet and Token Ring Any LAN interface card should be installed according to the manufacturer s instructions When Installing On Windows 2003 Server The Following steps to be executed before starting the PMCS installation 1 Right Click on My Computer Select Properties Select Advanced Below dialog is seen 16 Installing the Software PMCS Read This Book First System Properties 2 Click on Settings button under Performance heading Below dialog opens By default the second one Turn on DEP for all programs and services except those I select Instead of this select the first option as shown in the below dialog It says Turn on DEP for essential programs and services only PMCS Read This Book First Insta
44. instruction procedures provided by the manufacturer Installing the EPM Software Components The EPM7700 EPM 7600 and EPM 7500 Meters require additional software to operate with PMCS client software such as the Event Logger Waveform Capture Module or GE Wizards This is because the EPM devices are not compatible with the standard PMCS DDE Server Instead a separate DDE Server called the 7700 Gateway Server must be installed along with a pair of helper applications the Communications Server and the ION_Link Server The Communications Server processes all communications between the Gateway Server and or the ION Link and the Ethernet based EPM7700 EPM 77600 and EPM 7500 meters The EPM software components may be selected during the standard PMCS 6 15 installation routine If you are not using any EPM devices in your PMCS setup you do not need to install the EPM options during PMCS installation The EPM software components do require some special configuration beyond that required for other PMCS components Refer to the section titled EPM Device Special Considerations for details after running the PMCS installation routine described in this section PMCS Read This Book First Installing the Software e 19 Installing the PMCS software Once you have set up Windows 2000 SP4 and any third party software if appropriate you are ready to install the PMCS software PMCS should be installed last after all other software installations are
45. lling the Software e 17 Performance Options 24x Visual Effects Advanced Data Execution Prevention ul against damage from viruses and other security threats How does it work Turn on DEP for essential Windows programs and services only Turn on DEP for all programs and services except those I select t Fi Data Execution Prevention DEP helps protect Add Remove owes Click on Apply and then click on Ok button After this restart the PC and then start the PMCS installation process as mentioned in this document Installing Wonderware InTouch If Wonderware InTouch was provided with your PMCS software you must install it before proceeding If your computer already has InTouch installed make sure the following requirements are met e PMCS 6 15 has been certified to work with Wonderware InTouch for Windows NT Version 9 5 which is recommended for all new installations For upgrades PMCS 6 15 may be compatible with previous versions of InTouch for Windows 2000 SP4 but should be evaluated on a case by case basis depending on the specific application If you are installing InTouch follow the directions provided with the software inside the CD jewel case 18 e Installing the Software PMCS Read This Book First Installing Additional Software Install any additional software such as Microsoft Excel or COMTRADE file browsers for analyzing waveform files at this point in the procedure Follow the
46. mary Node Installation in Step 10 skip this step and proceed to Step 15 If you selected Secondary Node installation in Step 10 the following dialog box appears prompting you for the name of the computer on which the Primary Node is installed GE Power Management Control System Setup Primary Node Selection stall Shield PMCS Read This Book First Installing the Software e 35 13 If you chose the PMCS installation you may be presented with one or more DDE Server selections depending upon the PMCS catalog number you entered in the User Information screen Select only the DDE communications servers that you will be using in your system GE Power Management Control System Setup Setup Type Choose the setup type that best suits your needs Installshield 14 If you chose the Custom Installation then you will be presented with the dialog which gives option to select one DDE Server which is EIND option to select or deselect the wizards installation and option to select or deselect EPM7700 components the dialog shown looks as mentioned below 36 e Installing the Software PMCS Read This Book First GE Power Management Control System Setup E E xl Setup Type Choose the setup type that best suits your needs InstallShield PMCS Read This Book First Select or Deselect any or all of the below components to get them installed All other components as per the serial key will be installed
47. nfiguration WARNING Event Logger users only Upgrading your EventServer or Eventlogger application will result in the loss of all device configurations and annunciator panel items Make a list of these items so that they may be reconstructed in the new application Copy the existing PMCS EventLogger database files before starting the installation as they will be overwritten by the 6 15 installation To view databases created with earlier editions of PMCS use Microsoft Access to open the mdb files WARNING Generic Device users only On upgrading earlier versions of PMCS with PMCS 6 15 take the backup of Generic device by following this Export the device registry groups information and device mnemonic information before starting the installation and import them back after PMCS 6 15 installation is completed Installation of PMCS 6 15 over existing MSDE PMCS 6 15 uses MSDE 2 0 during its installation If you are installing PMCS 6 15 on a PC that already has MSDE 1 0 installed on it then there could be compatibility issues with the database files This could lead to crashes in the Events Applications For more information see Appnote102 Database Files Compatibility with MSDE pdf 46 e Installing the Software PMCS Read This Book First Page left blank intentionally PMCS Read This Book First Installing the Software e 47 Configuring the Software To get the most out of your new PMCS system follow the directions below to configure
48. ng the PMCS components you have selected you will be prompted to install the Adobe Acrobat Reader software If you do not have Acrobat Reader 5 0 or later installed on your PC you may wish to install Acrobat Reader at this time The PMCS CD ROM includes a full complement of technical documentation in Acrobat PDF format which may be viewed with the Acrobat Reader program The documentation is located in the TechDocs directory of the CD ROM Install Adobe Acrobat X 9 PMCS technical documentation is available in Adobe Acrobat amp Format on the CD Would you like to install the Adobe Acrobat Reader software now Yes No 2 When all the installations are complete the Setup Complete dialog box shown below prompts you to restart your computer 40 e Installing the Software PMCS Read This Book First GE Power Management Control System Setup InstallShield Wizard Complete Setup has successfully completed the installation Now close all other applications and restart the system Restart is required to enable the PMCS applications start up normally and automatically Yes want to restart my computer now No will restart my computer later Remove any disks from their drives and then click Finish to complete setup Back Cancel If No is selected and clicked on finish it will prompt the below message box and will again redirect to the above dialog asking to restart So select Yes to restart at
49. ns and View Nodes PMCS Installation Steps Note 1 When the system on which PMCS is being installed is not having any database server installed on it The PMCS 6 15 installation will go ahead by installing MSDE 2000 for PMCS databases This is applicable for all licenses where database installation takes place When the system on which PMCS is being installed is not having any Net Framework installed on it The PMCS 6 15 installation will go ahead by installing Net Framework 1 1 4322 This is applicable for all licenses When the on which PMCS is being installed is not having IIS installed The PMCS setup gives option to cancel installation install IIS and start PMCS setup again or continue with the installation If continued with installation without IIS installation then the installed PMCS system cannot be used by Remote Viewer Installation to connect as a PMCS Server setup On Windows 2003 Server machine after IIS is installed run the steps mentioned in Application Note 120 Adding ASP net component in W2K3 Server PDF either after PMCS installation or after PMCS installation During the steps of installation if cancel button is clicked then finish dialog pops up When Finish is clicked a message box titled Internal Error pops up Please click ok and it will cancel the installation AT PMCS Read This Book First any point of time you can again start with the PMCS installation without any problem This problem comes
50. ntral network configuration file that holds information for the workstation the network connections and every connected device You may want to restrict access to Network Builder or the network configuration file since if the file is tampered with EPM components may be rendered inoperable ION Designer Programming Devices and Software Nodes The ION Designer component allows you to customize the operation of an ION compliant node such as 7000 series meters and 3000 series meters Be aware that misuse of ION Designer can adversely affect the operation of your meters IMPORTANT For purposes of PMCS network compatibility it is CRITICAL that any EPM7700 EPM 7600 or EPM 7500 meters be configured with the GE PMCS standard configuration Using ION Designer to customize EPM7700 EPM 7600 or EPM 7500 functionality can compromise compatibility with the PMCS client applications attempting to access the device Communications Server System Communications The Communications Server is the core communications component for EPM meters The Communications Server manages all communications between the meters connected to your network and the GE77GTWY and ION_Link DDE Server software applications ION_LINK DDE Server Communication with Windows Applications The ION LINK DDE Server uses Dynamic Data Exchange to share information with applications such as Microsoft Excel and Wonderware Intouch PMCS Read This Book First EPM Devices Special Con
51. on such as 5 0 5 1 or 6 0 to PMCS version 6 15 This procedure assumes you have an existing PMCS installation with configured ports topics and optionally generic topics and that the GE Wizards are installed in the generic HMI application WARNING PMCS 5 1 and PMCS 5 1b Modbus DDE Server users only upgrading from PMCS 5 1 to PMCS 6 15 may cause the Modbus version of the DDE Server to lose its port configuration You may need to reconfigure your communications ports from the PMCS DDE Server after upgrading The Ethernet version of the DDE Server is not affected PMCS 5 0 users Port configuration is lost when a PMCS 5 0 configuration file is converted to a PMCS 5 1b configuration file You will need to reconfigure your communications ports from the PMCS DDE Server Refer to GEH 6510 for instructions Also any generic topics you may have configured at the PMCS DDE Server will be lost and you will need to re configure these generic topics Note While upgrading the previous versions to PMCS 6 15 a message appears saying that EPM 7330 device is configured as a generic device and in PMCS 6 15 this device is a tightly integrated device Ignore this message and proceed further 1 Close any open applications 2 Insert the PMCS Version 6 15 CD into the CD ROM drive 3 From Start menu select Run and enter X setup where X is the appropriate CD ROM drive designation 4 Read the general information and disclaimers shown on the screen
52. own below 72 netconfig dat Isl Sitel Add Ethernet Device x File View ltem General Advanced a E a Type Power Measurement 7700 ION r System ga PRIMARY 2 498 Software Group PRIMARY DDE 3 pes Mame EPM7700 Bion IP Address 3 45 3215 IP Service Port 7700 Priority Time i it ID Priority Unit ID 100 Thep Numbe Timenpoe b NUM Us Cancel Help Enter the following information Ready e Choose the meter type from the Type list Power Measurement 7700 ION e Type a name in the Group box or choose a Group from the list by default the Group will be the name of the workstation e Enter a name for the meter or accept the default The meter name must begin with a letter e Enter the IP address for the meter e Enter the IP Service Port number socket for the meter For a 7700 7600 or 7500 ION this number is 7700 for a 3720 ACM 3721 Saving and Exiting Once you have added all of your sites and devices to the network tree click the Save button or choose Save from the File menu and exit Network Builder You have now configured your EPM meters to operate with the PMCS and you should be able to access EPM metering data from PMCS client applications 60 EPM Devices Special Considerations PMCS Read This Book First Page left blank intentionally PMCS Read This Book First EPM Devices Special Consid
53. pendencies folder 3b Double click on the PMCS FS Web folder 3c Double click on PMCS FS WEB bat file 3d Double click on PMCS FS WEB msi file 3e It will prompt with the startup dialog click on Next will install the required components to make it to work for PMCS Remote Viewer Connectivity 3f Installation successful window is popped Click Close to complete the setup For Windows 2003 Server machine follow the below steps l First Install PMCS 2 Install IIS 3 Follow the steps mentioned in Application Note 120 Adding ASP net component in W2K3 Server PDF kept in PMCS installation CDYTech DocGE CD Application Notes This step can be executed either after PMCS is installed or before PMCS is installed but after IIS is installed 4 Inthe PMCS CD there is dependencies folder 3a Double click on the dependencies folder 3b Double click on the PMCS FS Web folder 3c Double click on PMCS FS WEB bat file 3d Double click on PMCS FS WEB msi file 3e It will prompt with the startup dialog click on Next will install the required components to make it to work for PMCS Remote Viewer Connectivity 3f Installation successful window is popped Click Close to complete the setup This will make the setup complete for setting up the PMCS server if IIS is installed after PMCS Un elicensing PMCS In order to unlicense your software to use your eLicense Order ID for another computer you must have an internet connection To retrieve your
54. propriate 2 Configure the applications As appropriate configure the application modules referring to the instruction manuals provided See step 3 of the Host PC Configuration for the appropriate instruction manual numbers PMCS Read This Book First EPM Software Components Configuration The EPM7700 EPM 7600 and EPM 7500 requires several separate software components which are installed during the PMCS 6 15 setup This section provides a brief overview of the steps required to configure these components the following section describes the EPM7700 components in greater detail For details of using the NetBuilder software refer to the Configuring the EPM7700 Device Network section of this manual and to DEH 40035 the GE 7700 Gateway User s Guide 1 Launch the NetBuilder application From the Start menu select Programs gt Power Management Ltd Utilities Network Builder 2 Insert a workstation s Normally all the workstations in a PMCS network are automatically configured during the installation of the software these instructions are provided in case you need to enter the information manually Select the Items menu from NetBuilder and choose Workstation to insert a workstation Name the workstation up to 15 alphanumeric characters the first character must be alphabetic and choose OK Repeat this step for each workstation computer in your network 3 Insert Ethernet Sites Select Items gt Insert gt Ethernet Site to inse
55. pter Refer to the screen shots above for an example though the selections will differ based on the hardware you are installing Ethernet requires the TCP IP protocol for compatibility with the Ethernet Gateway TCP IP should have been installed with Windows 2000 SP4 you can check this using Control Panel gt Administrative Tools gt Computer Management gt System Information Components gt Network gt Protocol The screen shot below shows a system with TCP IP installed If TCP IP is not installed on your system refer to the Windows 2000 SP4 documentation for installation instructions PMCS Read This Book First Installing the Software e 15 m Computer Management lol xj Action View Tools e 0m Ta 3 E3 I d e 39 Tree Computer Management Local i System Tools gal Event Viewer i i System Information gg System Summary C Hardware Resources C Components 31 1 Multimedia C Display Infrared 31 L Input C Modem 3 6 Network Adapter e E Winsock G Ports G Storage C Printing E Problem Devices uss 9 Software Environment 1 Mame ConnectionlessService GuaranteesDelivery GuaranteesSequencing Mame ConnectionlessService GuaranteesDelivery GuaranteesSequencing Mame ConnectionlessService GuaranteesDelivery GuaranteesSequencing Name ConnectionlessService GuaranteesDelivery GuaranteesSequenc
56. re RS485 An industry standard communication network supporting up to 32 networked devices RS485 provides medium speed reliable communication transport through shielding balanced transmission voltages and termination 8 e Getting Started PMCS Read This Book First SCADA Supervisory Control and Data Acquisition A category of systems that primarily acquires data for logging and analysis as well as providing supervisory control in applications without time critical requirements Power management systems are a direct application of SCADA technology TCP IP Transmission Control Protocol Internet Protocol An industry standard protocol typically used on Ethernet or Token Ring local area networks LANs User Screen Configurator An optional PMCS tool used to quickly generate accurate and friendly graphical user interfaces with third party generic HMI software tools The User Screen Configurator provides dozens of wizards to efficiently create intelligent one line diagrams equipment elevation views floor plans 3D virtual faceplate views and tabular displays Waveform Capture A standard PMCS application that provides a window into power quality data in an electrical system Waveform Capture is used to view snapshots of voltage and current waveforms from various points in an electrical system to analyze harmonics and unusual system behavior System Requirements The following table shows the minimum and recommended PC system confi
57. rt an Ethernet site Set the proper time synchronization options then choose OK Repeat this step to add additional sites to the workstation if necessary 4 Insert devices to the site Select Items gt Insert gt Device and complete the dialog box with the proper device type Group Ethernet address and name for an Ethernet device EPM7700 EPM 7600 EPM 7500 The device name may be no more than eight alphanumeric characters and the first character must be alphabetic The IP service port field must be 7700 for any EPM 7700 EPM 7600 or EPM 7500 connected to the Ethernet and 7800 for any additional device connected through an EPM7700 s RS485 port Choose OK to close the Insert Device dialog box Repeat this step as necessary to add additional devices to the site 5 Save and exit When all workstations sites and devices have been added select the save icon and then exit PMCS Read This Book First Configuring the Software e 51 EPM Devices Special Considerations Introduction The GE EPM7700 EPM 7600 and EPM 7500 devices add a new level of power management capabilities to PMCS These devices also require some special configuration which is not necessary for other PMCS compatible devices This section describes the additional requirements and configuration steps necessary to use the EPM7700 EPM 7600 and EPM7500 in conjunction with PMCS NOTE If you are not using the EPM7700 EPM 7600 or EPM 7500 meters in your PMCS network it i
58. s not necessary to read this section of the manual Although the EPM meters are compatible with PMCS and its client applications Waveform Capture custom wizards etc and EPM meters may co exist on the same Ethernet as other PMCS network segments the EPM meters use a slightly different metaphor than a straight PMCS network An EPM power monitoring network is comprised of a number of nodes that are connected to the PMCS workstation through Ethernet links Nodes in the power monitoring network are IEDs such as the EPM7700 meter power meters are also referred to meters or devices IEDs may be distributed across one or more networks as required to service the particular application EPM Software Components There are four major components of the EPM software The Network Builder ION Designer Communications Server and ION LINK DDE Server each interact to support the EPM7700 EPM 7600 and EPM7500 Meters When you selected the PMCS with EPM7700 Components selection during the PMCS installation routine these software components were installed automatically The four components and their functions are described below 52 e EPM Devices Special Considerations PMCS Read This Book First Network Builder Building the Network Configuration File The Network Builder presents a graphical view of the EPM devices in your network allowing you to easily add remove or configure sites services and meters Network Builder creates a ce
59. siderations e 53 Workstation Configuration Guidelines If you are using the EPM 7700 EPM 7600 or EPM 7500 Meter in your PMCS network the following guidelines in this section must be adhered to before continuing with the EPM configuration Note If you are adding a PMCS installation to an existing network please refer your network administrator to GEH 6502 the PMCS Network Architecture Guide for integration details e Each computer in the network must be assigned a Windows 2000 SP4 computer name The name must be one to fifteen alphanumeric characters in length Spaces may not be used and the first character of the computer name may not be numeric e The System Control Panel should have the Performance Boost for Foreground Application value set to None and a paging file should be created on the C drive with the Initial and Maximum sizes set to twice the workstation s installed RAM e The Network Control Panel s Adapter tab should have the MS Loopback adapter installed if a physical network adapter is not installed in the workstation Under the Protocols tab TCP IP or NetBEUI should be installed if TCP IP is installed use IP address 192 168 100 xxx and subnet mask 255 255 255 0 unless your network administrator has assigned you an IP address Under the Services tab install Remote Access Server RAS and configure it by enabling NetBEUI if using NetBEUI or if TCP IP is used assign two or more IP addresses starting at Xxx xxx
60. you look for these simple conventions e Boldface type indicates the name of an item you need to select e Monospace type indicates an example or text that is displayed on the screen e UPPERCASE type indicates a file name command name or acronym Introduction e 1 About Intouch PMCS Version 6 15 2 e Introduction PMCS Version 6 15 is the latest Power Management Control System in the robust line of POWER LEADER power management products from GE Multilin PMCS seamlessly integrates the comprehensive line of POWER LEADER devices as well as many new Modbus RTU devices and systems PMCS comes with built in Ethernet compatibility and is optimized for the Windows 2000 SP4 operating system All of this adds up to the most flexible high performance open architecture power management system available PMCS software is the backbone of your new power management system with state of the art graphics and features designed to maximize productivity and minimize downtime and energy costs Performance With built in Modbus RTU and Ethernet compatibility PMCS delivers critical power management information faster than ever PMCS supports baud rates of up to 38 4 kbps on a Modbus RTU network and 10 Mbps on an Ethernet TCP IP network This results in near real time screen refresh rates and immediate access to critical event and alarm data Features PMCS comes with the following features that make the system more powerful and easy to use
61. your system Organize Your Information Host PC You need the following information to properly configure the PMCS software for the Host PC This information is used throughout the configuration process and you should archive it for any future maintenance of your system For RS485 PMCS network interfaces you need to list all devices in the power management network including Modbus Concentrators with associated device types Modbus RTU addresses and COM ports Assign names of less than 20 characters no spaces to these devices For example in a simple system with four devices and one Modbus Concentrator you may have a table similar to the following Device Topi Name MODCONC wa E Wai eter M Merer Wf Breaker Mil Rey For an Ethernet PMCS network interface you must list all devices in the power management network including the device types and Modbus RTU addresses You need to know the appropriate Ethernet Gateway IP address and COM port 1 4 to which each device is connected Assign names of less than 20 characters no spaces to these devices For example in a simple system with 10 devices you may have a table similar to the following this system uses one Ethernet Gateway and three Modbus Concentrators 48 e Configuring the Software PMCS Read This Book First Ed E EE eene PO IP Address port Address Device Type Device Topic Name maam f fp eem nee 07 10 47 28 201 E3720 Main Meter moam p 3 ne
Download Pdf Manuals