PG-FP4 Flash Memory Programmer UM
Contents
1. AC adapter 15 V 1 A RS 232C cable cross Note 1 Parallel interface cable FA adapter or STATUS 3 k er N U i PG FP4 FlashPro4 lo pie alc Target cable USB interface cable Notes 1 The parallel interface cable is not included in the PG FP4 package 2 The FA adapter board is a product of Naito Densei Machida Mfg Co Ltd The PG FP4 is connected to the host system via an RS 232C serial interface cable or a USB interface cable By using the serial interface in combination with the optional parallel interface the user program can be quickly downloaded to the PG FP4 The PG FP4 is connected to the user system by the target cable For the detailed specifications of the target cable refer to CHAPTER 7 CONNECTORS AND CABLES 2 3 1 Host computer A PC is used to communicate with the PG FP4 Windows 95 Windows 98 Windows NT Windows Me Windows 2000 or Windows XP is required for GUI software operation of the PG FP4 It also must be equipped with a serial interface or a USB port An optional parallel interface may be used for fast program download to the PG FP4 Remark USB support is not available on Windows 95 and Windows NT 14 User s Manual U15260EJ4VOUM CHAPTER 2 HARDWARE INSTALLATION 2 3 2 PG FP4 control panel and connectors Figure 2 2 PG FP4 Top View Next D y NI r Serial host
2. Supply voltage dd v 05 00 Vdd pv 00 00 On Target ia Yoo M 00 00 Clk Vdd Serial Fort Reset dd H S Input dd Program downloadupload i Enable two Program Areas lt 1 gt Supply voltage PK Command options W Blank check before Erase Read verify after Program Security flag after Program Checksum after Program Security flag settings W Disable Chip Erase Disable Block Erase Disable Program i Disable Read Disable Boot black cluster reprogramming Reset vector hi Boot block cluster setting End Boot block 16 Show Address ome soy The supply voltage section allows you to specify the voltage levels for target device programming Depending on the target device type one Vpp or two Voo and Vop2 voltage levels need to be specified In general Vobo Von2 voltages that are supplied when the target device is programmed should be supplied by the target system Although they can be supplied by the PG FP4 the current flow is not large enough to operate the whole target system maximum of 200 mA Therefore supply voltage via the PG FP4 only when a dedicated writing adapter such as an FA adapter is used User s Manual U15260EJ4VOUM 61 62 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Figure 4 29 Setup Window Supply Voltage Supply voltage Vdd w Vode v r On Target Wpp E Clk Seral Port Heset H S Input Vdd V
3. D2 D4 D 13 H HHBHCH FE 64 13 AB BH 13 AZ BH 13 27 FF 13 25 FF OF FF U eeu ee HHBHDH B1 BS BS Bf 89 10 D6 B7 AE 88 76 AE 09 DS BF FH 1 ap BHBBEB AE 81 75 86 86 C6 B BE 89 66 BE 88 C6 3H 61 IC u a Ba HHG0F OH 36 61 3D 99 1C D4 12 BA BA JA Z 81 E BA B2 B ask 060160 AF FF B1 BS 22 C 36 61 10 36 61 3D 9D 20 36 61 Ha Ha 6a 060110 BA 36 37 61 2B 37 34 61 BA 34 35 61 2B 35 23 96 Za 4a 45a 5 69612 0 94 87 95 92 61 71 61 6A 61 B BD F3 FA 12 23 BS mE aqajak H86130 B7 87 95 86 84 92 61 71 61 GA 61 6B BD F3 B B4 B agajak o 6660140 B BO AF FF 9A DO AA C O BF 89 1C E6 16 BH E8 nae woes 060150 36 BE B 36 BE Z B 13 AZ 365 13 AB 71 2B 27 A A ere aoa BHG168 71 1B 27 71 BB 27 1B 07 GA BF 13 25 86 11 8S FF g q ee 8170 71 6A AB 71 7A AB FO 1A 72 89 1C D6 62 97 AS BH g qz r bi HH6186 AS 81 168 86 18 BE Z 68 BE 86 18 FF FF BE 83 ET H86196 BE 82 16 FB DD 12 43 O BE Y 68 BE 68 C2 BE B i1 C HHG1AG 66 BE BA C 9A 9B 83 EA N A BD C AE 8 3H AE HHB1BA 83 86 38 BE 82 38 BE 83 AE 82 78 AE 83 61 68 BD 6 p ah The displayed file can be modified by placing the mouse cursor inside the HEX Editor main window Data input via the keyboard is accepted for all shown memory locations The HEX Editor accepts data only in h
4. Displays the default Vdd level set by the parameter file in volts V This Vdd level can be changed by input Vdd2 V Displays the default Vdd2 level set by the parameter file in volts V If the specifications of the target device require two types of Vdd for writing the flash memory Vdd2 specifies a low level signal voltage This voltage level can also be changed by input On Target check box Check On Target if the Vpp Vpp2 voltages are supplied from the target system The power supply detection function of the Vpp pin differs depending on the setting of the On Target check box e When Vpn is set to be supplied from FP4 On Target not checked If Target Voo reaches 0 2 V before Voo is supplied the error message Target power detected Check Setup is displayed in the communication Log window e When Vpn is set to be supplied from the target On Target checked If Voo is outside the range of 5 of the Voo set value just before communication starts the error message No VDD applied or Voltage is out of range is displayed in the communication log window Caution Set the values of the Vpp Vpp2 voltages supplied by the target system as Vdd V and Vdd2 V before checking On Target The target system may be damaged if proper values are not set Users Manual U15260EJ4VOUM lt 2 gt CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Vpp Clk Serial Port Reset H S Input Display the default level of each pin set
5. F ter fil Parallel port in remote control mode ee FOF 30254 PAM progearea Version 1 03 Active Program Area ee cane saut evice Setting file ee ae Name 70F30254 SET gt downprm Date Tue May 11 21 30 30 loading Domrioag fie ame my application nex Nook tah Date Fri Jul 18 10 06 50 2003 OK DA 1 ng fic Sine tae dae Ti he Same oe a Oe am Chkeum BE 2B AF sonoganes Prog 4rea off Progran Area usage disabled E T lod tname ny_application Fort sed to device Erasing external Flash 0OK ai l 5 How loading 0K Pulse Num O Address range Ux000000 to 0x0001i0 Speed b25000 ORC no_store Wid 05 00 Checksum OOO00000 OOLFFFFF O1BB3B2F Supply A Freg 6000000 Multiply 5 00 Block 4rea Address File Checksum Address 76 User s Manual U15260EJ4VOUM CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE 7 Executing EPV command Select Device Autoprocedure EPV Figure 5 14 Erase gt Program gt Verify EPV Menu Toolbar NI FP4 File Frogrammer Device Help Blan check Erase Program rprogarea Active Prog Aubtoprocedure EF rautocon on Autolon is c Connect gt downpri Signature read How loading 5 ae Get Securit Settings How loading c etup OK mai When the EPV command is executed checking the checksum value of the user program Blank check Erase Program and Verify are executed in tha
6. computer click Change Remove SECU isu Add Remove Windows Components Set Program Access and Defaults All files installed during setup will be removed from your hard disk except the parameter files PRM and customized setup files SET User s Manual U15260EJ4VOUM 33 CHAPTER 3 SOFTWARE INSTALLATION 3 2 Firmware and GUI Software Update Installation In order to guarantee proper operation of the PG FP4 programmer it is mandatory that the correct firmware version be available in the programmer s internal memory Be sure to follow the procedure below when updating the firmware lt Procedure gt 1 Upgrade the GUI software 2 Update the firmware using the new GUI software The GUI software will perform a crosscheck of software versions between the installed GUI software and the firmware in the PG FP4 If the GUI software is not the latest the following a warning message will appear Figure 3 24 Warning About Old GUI Software Version Firmware Yersion Error E 205 The firmware you are using requires an update of the GUI The FP4 GUI may not work properly If the firmware is not the latest the following warning message will be displayed Figure 3 25 Warning About Old Firmware Version Firmware Update x E 206 Your firmware i not up to date Updating the firmware will take several minutes ATTENTION The process of updating vour firmware must MOT be interrupted Without new firowa
7. and click the button The Locate Driver Files window will be displayed User s Manual U15260EJ4VOUM 29 CHAPTER 3 SOFTWARE INSTALLATION Figure 3 17 Locate Driver Files Window Found New Hardware Wizard Locate Driver Files Where do you want Windows to search for driver tiles Search for driver files for the follawing hardware device USE Device The wizard searches for suitable divers in ite driver database on your computer and in any of the following optional search locations that you specify To start the search click Nest IF you are searching on a Hoppy disk or CO AOM drive Insert the floppy disk or CO before clicking Next Optional search locations Floppy disk drives M CO ROM drives I Specify a location Revere eee seman we aisles Pena weds ache Microsoft Windows Update lt Back Cancel Check Specify a location and click the button The window for specifying the USB driver files to be copied will be opened Figure 3 18 Window for Specifying Driver Files to Be Copied 1 Found New Hardware Wizard i _ x f Insert the manufacturer s installation disk into the drive selected and then click OF Cancel Copy manufacturer s files from G Browse Specify the directory where the driver exists and click OK You can specify the directory from the Locate File window after clicking Browse 30 User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALL
8. Connect the RESET signal of the PG FP4 at a point where the status of the programmer RESET signal and that of the CPU RESET pin are the same Correct connection Avoid the following RESET signal connection e Connection to a point where the target CPU RESET rise time is slower than the PG FP4 RESET rise time Incorrect connection It takes time for the CPU RESET pin to go high after the PG FP4 RESET level goes from low to high 94 User s Manual U15260EJ4VOUM CPU Pin RESET Serial interface pin CHAPTER 8 NOTES ON TARGET SYSTEMS Design Proposal e Connection to a point where the target CPU RESET pin cannot be driven to low level by the PG FP4 RESET signal Incorrect connection PG FP4 RESET When the PG FP4 RESET is driven low the level of the voltage at point A does not fall When the CPU port used by the PG FP4 is also connected to the input of an external device and if that device malfunctions disconnect the external device or make it output high impedance Example PG FP4 connector SO TxD External device While the CPU port used by the PG FP4 is also connected to the output of an external device and if a signal collision occurs disconnect the external device Example PG FP4 connector SI RxD Collision External device User s Manual U15260EJ4VOUM 95 CHAPTER 8 NOTES ON TARGET SYSTEMS CPU Pin Design Proposal Keep the wiring between the PG FP4 connector and the CPU Vpr pin
9. PRG Area indicates which of the areas of the target device connected to the PG FP4 is to be programmed This menu is valid only when the operation mode is other than chip only when area or block is displayed in the above mode Display example PRG Area Oto 1 In the chip mode the display is always as follows PRG Area O to O User s Manual U15260EJ4VOUM CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE 6 1 3 Option Setting menu The Option Setting menu is used to check the command option and security flag currently set for the PG FP4 All the displayed values were set during the last programming session The setting cannot be changed on this menu Option Setting gt e Pressing the Next button displays the Voltage Setting menu e Pressing the Enter button displays the following commands that can be executed on the Option Setting menu e Pressing the Cancel button displays the Commands menu again BLN before ERS Displays the set status of the command option Blank check before Erase as either of the following on Blank check is executed before execution of the Erase and EPV commands If the result of the blank check is OK erasure processing is not executed off Blank check is not executed before execution of the Erase and EPV commands J Next button VRF after PRG Displays the set status of the command option Verify after Program as either of the following on After execution of the Program and EPV commands the write d
10. Parallel host a znt a F connector connector x n a Cancel Power connector STATUS a Target interface USB port 7 g 7 PG FP4 FlashPro4 connector Control Message Status LED buttons display The control buttons are used in the standalone mode of the PG FP4 Next button Proceeds to the next menu item in sequence Enter button Selects the item shown in the message display Cancel button Cancels the current selection and returns to the previous menu item Message display A 16 x 2 character LCD display indicates the operating mode It is mainly used for the PG FP4 s standalone mode Status LED The LED shows the PG FP4 operating status indicated by the colors green for OK red for Error or orange for Operating 1 PG FP4 connectors The serial host connector the target interface connector and the power connector are located on the right side of the PG FP4 Figure 2 3 PG FP4 Target Interface Power Serial Host Connectors lt Right side of PG FP4 gt o0000 o O 00000 o000 User s Manual U15260EJ4VOUM 15 CHAPTER 2 HARDWARE INSTALLATION The parallel host connector and USB port are located on the left side of the PG FP4 The parallel host connector can be used for high speed downloading of a program as a Centronics interface Figure 2 4 PG FP4 Parallel Host Connector USB Port Interface lt Left side of PG FP4 gt 2 3 3 Target system The target system mus
11. The following window opens Figure 4 22 Device Setup Window Standard Menu Properties a Standard Advanced Device Setting file CAPROGRAM FILESSFL PRA4SSET New a Saveds _ Parameter file 70F 30254 PRM Defaults Communication interlace ta device Pat 510 ch0 Pulse number g Speed 625kH2 Multiply rate Intemal Direct mode We Aoohess oo i PLL mode 5 00 Operation Mode Chip Start fo Selective Pragraniminaf enii Read Block End ho o a Start oona0d Supply oscillator Frequency 6 MHz ha On Target Hz M i Area oF T Show Address End U2r FFF This window shows all basic options that can be set in accordance with the user environment and target device OK button Clicking the button saves the setting contents on the Standard and Advanced menus to the customized setup file SET and downloads them to the PG FP4 with a specified parameter file PRM Apply button This button is valid if settings have changed on the Standard or Advanced menu Clicking the button saves the contents of new setting to the customized setup file SET Note that this button only saves the settings to the file it does not download them to the PG FP4 Users Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Cancel button When the button is clicked the contents set on the Standard and Advanced menus are not downloaded to t
12. lt When UART ch0O UART ch1 UART ch2 or UART ch3 is selected gt 9 600 baud 19 200 baud 31 250 baud 38 400 baud 57 600 baud 76 800 baud 115 200 baud 128 000 baud 153 600 baud lt When Port chO Port ch1 or Port ch2 is selected gt 100 Hz 200 Hz 300 Hz 400 Hz 500 Hz 600 Hz 800 Hz 1 000 Hz 1 200 Hz 1 500 Hz IIC Address If C is selected as the programming channel input a slave address as a hexadecimal number The valid range of input is 8 to 77H Do not input a unit The slave address can be any value in the above range but must not be the same as the slave address of another device on the I C This field cannot be accessed if the I C port is not selected Users Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE lt 3 gt Supply oscillator Supply oscillator selects the oscillator that determines the programming data transfer and transfer rates Figure 4 26 Setup Window Supply Oscillator Supply oscillator Frequency G MHz On Target H M Multiply rate Intemal Direct mode f PLL mode 5 00 On Target check box Specifies whether the clock signal is supplied from the PG FP4 or target device If this is checked the clock of the target system is used If it is not checked the clock of the PG FP4 is supplied to the target Frequency list box Sets the oscillation frequency for signal generation When using the clock of the target system when the On
13. 3 3 appears to indicate the progress Figure 3 3 Setup Preparation InstallShield Wizard PG FP4 Setup is preparing the InstallShield Wizard which will guide vou through the rest of the setup process Please wait The welcome screen appears a short while after initialization Figure 3 4 Welcome Window Welcome to the InstallShield Wizard for PG FP4 The InstallShield Wizard will install PG FP4 on your Computer To continue click Hest Cancel Click to continue the installation 20 User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALLATION Next a window for selecting a setup type will be opened Figure 3 5 Setup Type Selection Window setup Type Choose the setup type that best suits your needs hetals hela Select English or Japanese and click Next gt User s Manual U15260EJ4VOUM 21 22 CHAPTER 3 SOFTWARE INSTALLATION The software License Agreement window appears Figure 3 6 Software License Agreement Window License Agreement Please read the following license agreement carefully Press the PAGE DOWN key to see the rest of the agreement USER LICENSE AGREEMENT IMPORTANT READ CAREFULLY This User License Agreement ULA amp is a legal agreement between you ether a natural person or an entity and HEC Electronics Corporation NEC for the SOFTWARE PRODUCT As used herein SOFTWARE PRODUCT means the NEC softw
14. ATTENTION e The process of updating your firmware must NOT be interrupted e Without firmware this FP4 GUI will NOT run properly Install new firmware in your programmer E202 Checking address data failed Signature command returned unexpected character E203 Evaluating area data failed Signature command returned unexpected character E204 Unknown Version of ooo firmware Refer to 3 2 1 Firmware update installation for a The FP4 GUI may not work ooo description of these messages E205 The firmware you are using requires an update of the GUI The FP4 GUI may not work properly E206 Your firmware is not up to date Updating the firmware will take several minutes ATTENTION The process of updating your firmware must NOT be interrupted Without new firmware this FP4 GUI will NOT run properly Install new firmware in your programmer E207 Wrong firmware in programmer The GUI may not work properly E208 The programmer memory does not contain the Before issuing an EPV command the GUI software verifies most recent downloaded file different CRC proper application file contents by verifying the actual CRC Please download your user application s again with the one saved after file download to FP4 ini E209 Searching for a port communicating with the No communication with the programmer could be programmer failed established at all Sequence of connecting the PG FP4 on Please check the connection start up of the GUI so
15. Device Setting gt Dialog Box Properties Pl x Standard Advanced Supply voltage Command options Vdd 05 00 Vode v 00 00 r Yop w fi 0 30 Clk Blank check before Erase M Read verify after Program Security lag efter Program On Target g M checksum after eagran Securty flag settings M Dreahle chip Erase Disable Block Erase m ieahle Program Disahle Read Vdd Serial Fort Reset Vdd HS Input vdd Program download upload ee ee ere re eer End Boot block 0 a ee es el hawtddess cat too Check the information of Supply voltage to confirm that the settings are in accordance with your M Dyeahle Boot black cluster rearogranming Reset vector oonand h Boot block cluster setting programming environment To supply the target Vop enter the value of the target Vono in Vdd V and Vdd2 V and check the On Target check box It is assumed that the following settings are made in this example lt Supply voltage gt Vdd V 5 00 V in accordance with the set value of the parameter file Vdd2 V 0 00 V not used in accordance with the set value of the parameter file On Target Not checked Vdd is supplied from the PG FP4 to the target lt Command options gt Blank check before Erase Checked fixed to default Read verify after Program Checked lt Security flag settings gt Not used lt Program download upload gt Enable two
16. FP4 Display example PRM Name 70F3025A J Next button PRM File Version PRM File Version displays the version of the parameter file stored in the PG FP4 J Next button HEX File Name HEX File Name displays the name of the downloaded file stored in the specified valid memory area in the user program area of the PG FP4 It displays n a if the downloaded file is invalid The file name is displayed after either of the following steps are executed 1 After downloading a user program into the user program area that is specified as a single memory area use the user program as two independent memory areas Area 0 and Area 1 2 After downloading a user program into either Area O or Area 1 switch the valid memory area to the other memory area J Next button CRC Sum PG FP4 CRC Sum PG FP4 calculates and displays the checksum value of the valid memory area specified in the 2 MB user program area of the PG FP4 Display example CRC Sum PG FP4 6AEDF4F4 86 User s Manual U15260EJ4VOUM CHAPTER 7 CONNECTORS AND CABLES 7 1 Power Supply Connector The power supply connector is located on the right side of the PG FP4 Figure 7 1 Power Supply Connector Figure 7 2 Pin Configuration of Power Supply Connector The specifications of the power supply are AC input range 100 V to 240 V 47 Hz to 63 Hz DC output 15V Current consumption 0 8 A max Caution Connect only the provided AC adapter to the power supply jack of the
17. FP4 INI file failed E800 Illegal address The end address entered in the HEX Editor is lower than the start address E801 The file cannot be read Processing the selected file in the HEX Editor failed E802 No HEX data The file format could not be read in the HEX Editor E803 The file cannot be written The Windows write file function failed in the HEX Editor E804 cannot open lt file name gt The Windows file open function failed in the HEX Editor abort E805 cannot open file A NULL handle was returned when a file was opened in the HEX Editor E806 Check sum error The HEX Editor detected a faulty checksum The Continue checksum will be corrected if continuing E808 Invalid file name The specified file could not be found in the HEX Editor E809 lt file name gt could not be opened The Windows file open function failed in the HEX Editor abort E900 Unable to open last active PRM SET file Using The FP4 INI file does not exist or contains invalid entries most recent settings for RecentPrmFile or RecentSet File The first PRM file from sub directory PRM will be loaded instead Searching for fo4com dll failed Cannot find Communication DLL fp4com dll Reinstall PG FP4 software Unable to find any PRM file Please install PRM Sub directory PRM does not exist or valid PRM file does files not exist in the sub directory PRM Download of PRM file failed An error occurred while attempting to download a PRM file The PRM file may be
18. Found New Hardware i USE Device Installing 28 User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALLATION Figure 3 15 Welcome to the Found New Hardware Wizard Window Found New Hardware Wizard i i Welcome to the Found New Hardware Wizard This wizard helps you install a device driwer for a hardware device To continue click Next Cancel You can exit the installation by clicking the button Click the button to install a USB driver Next the Install New Hardware Wizard window will be opened Figure 3 16 Install New Hardware Wizard Window Found New Hardware Wizard i Install Hardware Device Drivers A device driver is a software program that enables a hardware device to work with an operating system This wizard will complete the installation for this device a USB Device A device driver it a software program that makes a hardware device work Windows needs driver files for your new device To locate driver files and complete the Installation click Next What do you want the wizard to do Search for a suitable driver for my device recormendedt leme EEE EE e E bas Cote Eh ee ety cA ee teks LAR ep Rete EE LEED Ftd a tne eat hee Peed nats Lhe eae be Display a list of the known drivers for this device so that can choose a specific driver lt Back Cancel Select Search for a suitable driver for my device recommended under What do you want the wizard to do
19. GUI SOFTWARE This chapter explains a series of basic operations of the PG FP4 with the GUI software taking a case where the UPD70F3025A is used as the target device as an example This chapter covers how to start the system execute the EPV command and program the target device 68 For the other commands and applications refer to CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE e Series of operations described in this chapter Here are the operation conditions of this chapter HOST interface RS 232C interface Target UPD70F3025A with FA adapter Communication interface SIO H S 625 kHz Supply oscillator In PG FP4 6 MHz multiplied by 5 Operation mode Chip Supply voltage Supplied by PG FP4 Command options Read verify after Program check Verification is executed after program command Program download upload No check with user program 1 code only Installing GUI software Install the PG FP4 GUI software in the PC you are using by referring to CHAPTER 3 SOFTWARE INSTALLATION if the software has not been installed yet Installing parameter file Copy the parameter file for the PD70F3025A to the hard disk and install it in lt FP4 install path gt PRM Download the parameter file from the following http www necel com micro ods eng index html Connecting system lt 1 gt Connect the PG FP4 to the computer with the supplied RS 232C cable lt 2 gt Select an appropriate AC plug from those supplied with th
20. Logfile eae GUI software Sey SSeS USB operation e Device parameter setup Ql e On board programming e FA adapter programming Calculate Use as one storage area or checksum split into two areas _ Hex Editor to modify memory contents User s Manual U15260EJ4VOUM 11 CHAPTER 1 OVERVIEW The graphical user interface GUI of the PG FP4 supports the device commands necessary for downloading and uploading user programs setting parameters necessary for writing the device setting and selecting a writing environment by the user changing the user program downloaded to the PG FP4 and calculating and rewriting the memory checksum The parameters necessary for writing the device are saved to a parameter file PRM file and the setting of the user s writing environment is saved to a customized setup file SET file These files are downloaded to the PG FP4 and stored in the internal EEPROM so that the downloaded data can be used even in the standalone mode The GUI software is executed using the parameters that have been set last Changed settings are saved to an INI file Communication between the GUI software and the PG FP4 is recorded in an ASCII file The internal memory of the PG FP4 is configured as a 2 MB flash memory and holds the user program that is written to the target device This memory s area progarea can be divided into two 1 MB memory areas Therefore the PG FP4 can download two differe
21. PG FP4 User s Manual U15260EJ4VOUM 87 CHAPTER 7 CONNECTORS AND CABLES 7 2 HD Sub 9 Serial Host Connector The serial host connector is located on the right side of the PG FP4 Figure 7 3 HD Sub 9 Serial Host Connector Figure 7 4 Pin Configuration of HD Sub 9 Serial Host Connector ED Table 7 1 Pin Configuration of HD Sub 9 Serial Host Connector S a er o h 7 2 1 RS 232C cable crossed The host cable is a standard shielded RS 232C cable of 2 meter or 3 meter length The connectors on both sides are D SUB 9 pin connectors female Figure 7 3 shows the connection Figure 7 5 Host Cable Connections O ON OU BP W N e O ON OU RA WU N e 88 User s Manual U15260EJ4VOUM CHAPTER 7 CONNECTORS AND CABLES 7 3 HD Sub 15 Target Interface Connector The target interface connector is located on the right side of the PG FP4 Figure 7 6 HD Sub 15 Target Interface Connector Figure 7 7 Pin Configuration of HD Sub 15 Target Interface Connector 15 11 Table 7 2 Pin Configuration of HD Sub 15 Target Interface Connector PF FP4 HD Sub 15 Signal Name of PG FP4 SI RxD HD Sub 15 connector part number HT1566G3 PROVERTHA Steckverbinder GmbH User s Manual U15260EJ4VOUM 89 CHAPTER 7 CONNECTORS AND CABLES 7 4 Target Cable Specifications The target cable is equipped with two connectors for the FA adapter Figure 7 8 Target Cable Outline Type B
22. PG FP4 is Note erased programmed and verified J Next button Note Download a user program in advance in the GUI software mode This is valid for the programming area Chip Block and Area currently set for the PG FP4 80 User s Manual U15260EJ4VOUM Program gt J Next button Erase gt J Next button Verify gt J Next button Security gt J Next button Checksum gt J Next button Blank check gt J Next button Signature gt J Next button Prog Area gt CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE When the Enter button is pressed next the target device connected to the PG FP4 is Notes 1 3 programmed When the Enter button is pressed next the target device connected to the PG FP4 is Note 3 erased When the Enter button is pressed next the target device connected to the PG FP4 is Notes 1 3 verified When the Enter button is pressed next the security flag of the target device connected to the Note 2 PG FP4 is programmed When the Enter button is pressed next the checksum value entire flash memory area of the target device of the target device connected to the PG FP4 is read The read checksum Notes 2 3 value will be displayed on the message display When the Enter button is pressed next blank check of the target device connected to the PG FP4 is executed When the Enter button is pressed next the signature of the target device connected t
23. Program Areas Not checked User s Manual U15260EJ4VOUM CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE lt 8 gt Click the button The GUI software will load the parameter settings to the PG FP4 When the settings have been completed the next screen is displayed Figure 5 11 Completion of Parameter Settings Bootloader Version V1 14 Firmware Version 1 30 sotr off Parallel port in remote control mode sDrogarea Active Program Area OU rautocon on Autolon i on gt downprm Now loading sprogarea Progran Area usage disabled gt User s Manual U15260EJ4VOUM 75 CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE 6 Downloading user program e Select File Download Figure 5 12 Opening Program File to Be Downloaded Select a File to download afz Toolbar E Look in E Gui ce drivers Pim pa Cet E my_application hex Files of type S tec Hex files recs 32 hes Cancel lt 1 gt Select the name of the file to be downloaded and click to start the downloading sequence While the program is being downloaded a window indicating the progress is displayed When downloading is complete the following screen is displayed Figure 5 13 Completion of Downloading FP4 Pile Es File Programmer Device Help A8 XN Device Name OFSO254 Status auboconnected Bootloader Version V1 14 Firmware Version 1 30 rctr off
24. Target check box is checked input the frequency to be used When using the clock of the PG FP4 when the On Target check box is not checked select a frequency from the following e 1 MHz e 2 MHz e 4 MHz e 5 MHz e 6 MHz e 8 MHz e 10 MHz e 12 MHz e 16 MHz e 20 MHz Note that the frequency range in which a device can operate differs depending on the device Check the specifications of the device before setting the frequency Multiply rate Specifies the division rate or multiplication rate of the target device If the target device has a PLL circuit select the PLL mode and enter a division rate or multiplication rate in accordance with the environment used The selectable division rate or multiplication rate differs depending on the device Confirm the specifications of the device before setting them If the target device does not have a PLL circuit select the Internal Direct mode In the initial screen the default settings set by the parameter file are displayed Users Manual U15260EJ4VOUM 59 60 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE lt 4 gt Operation Mode Operation Mode may divide the flash memory of the target device into blocks or areas This menu is used to select the operation mode of the flash memory Some devices do not have either or both division modes Block and Area In this case a mode that is not available cannot be selected Figure 4 27 Setup Window Operation Mode Operation M
25. and the processing of the other pins by referring to the user s manual of the target device Check if the following set values match the actual writing environment by selecting the Device Setup menu Clock supply source Vpp supply source Communication mode to be used Parameter file etc Check to see if the CPU clock and communication clock are within the range of the specifications of the target device When UART is used communication may not be synchronized due to a baud rate error of the target device In this case change the CPU clock or baud rate or change the communication mode to SIO User s Manual U15260EJ4VOUM CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE The PG FP4 has a standalone mode in which the PG FP4 itself can execute the Erase Program and Verify commands without a host This mode is useful for using the PG FP4 on the production line during mass production and for upgrading the version at a customer s site In the standalone mode the PG FP4 uses the flash programming parameters stored in the internal EEPROM area Therefore a new device cannot be selected for flash programming nor can the programming parameters be changed Programming can be done only in the environment set last in the GUI software operation mode In the standalone mode select and execute the command menu by using the control buttons Next Enter and Cancel at the upper part of the main unit of the PG FP4 Th
26. cable switch the PG FP4 on When it is started up correctly the message display shows the Commands gt prompt and the status LED is switched off If the above does not happen the PG FP4 may be faulty In this case contact an NEC Electronics sales representative or distributor GUI software startup To start the PG FP4 GUI software select FP4 EXE or double click the shortcut if it has been created The PG FP4 starts communicating using the most recently used communication parameters stored in its internal EEPROM The default communication speed is 9 600 bps The GUI software establishes a connection with the PG FP4 using the GUI section parameters in the FP4 INI file HostConnectionSpeed HostConnectionPort and HostDownloadPort When no FP4 INI file exists this is the case when starting the GUI software for the first time the GUI software scans the connection via COM1 to COME in each port at 9 600 bps 19 200 bps 38 400 bps 57 600 bps and 115 200 bps to establish communication with the PG FP4 using the USB Figure 4 2 Port Scanning at Startup of GUI Software Trying to connect COM with 9600 Baud ln Operation You may interrupt this operation by clicking ABORT and select the correct communication parameters from the Programmer Setup host connection menu User s Manual U15260EJ4VOUM 37 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE As soon as communication is established and the GUI software is
27. clicking this menu item you can execute a software reset of the programmer The communication window will show the current version of the PG FP4 firmware after the reset 5 Update Firmware menu Clicking this menu item updates the PG FP4 Before starting the update download the necessary upgrade data from the NEC Electronics Website at http www necel com micro ods eng index html When the firmware update is started the following confirmation message is displayed first Figure 4 16 Firmware Update Window Firmware Update 3 x l E 201 Updating the firmware will take several minutes ATTENTION The process of updating your Firmware must WOT be interrupted without Firmware this FP4 GUT will NOT run properly Install new Firmware in your programmer To continue the firmware update click Yes When is clicked the firmware update is canceled When is clicked lt Select a File to download gt will be displayed Figure 4 17 Select a File to Download Window Select a File to download a ajx Look in a PG FP4 0a __ drivers fet up vi20 rec File name ip _vup vi 2 rec Files of type S tec Hex files rec s2 hex Cancel i Erase memory before download 48 User s Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Select the firmware update program file FP4_WUP_xxx REC and then click Open Some commands will be transferred to the PG FP4 a
28. electronic appliances machine tools personal electronic equipment and industrial robots Special Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems anti crime systems safety equipment and medical equipment not specifically designed for life support Specific Aircraft aerospace equipment submersible repeaters nuclear reactor control systems life Support systems and medical equipment for life support etc The quality grade of NEC Electronics products is Standard unless otherwise expressly specified in NEC Electronics data sheets or data books etc If customers wish to use NEC Electronics products in applications not intended by NEC Electronics they must contact an NEC Electronics sales representative in advance to determine NEC Electronics willingness to support a given application Note 1 NEC Electronics as used in this statement means NEC Electronics Corporation and also includes its majority owned subsidiaries 2 NEC Electronics products means any product developed or manufactured by or for NEC Electronics as defined above M8E 02 11 1 4 Users Manual U15260EJ4VOUM Regional Information Some information contained in this document may vary from country to country Before using any NEC Electronics product in your application please contact the NEC Electronics office in your country to obtain a list of authorized representatives and distributors Th
29. follow the procedure in the 1 Firmware update installation from warning message above Figure 3 27 Update Firmware Menu File Programmer Device Help setup host connection Loge ine select Programming area gt yer Reset Update Firmware The PG FP4 is now ready for operation User s Manual U15260EJ4VOUM 35 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 4 1 Introduction Before you start using the PG FP4 download the parameter file for the target device PRM to the PRM folder lt Downloading the parameter file gt The PRM file is not part of the PG FP4 software package It has to be downloaded from the NEC Electronics Website at http www necel com micro ods eng index html The PRM file downloaded from the NEC Electronics Website must be copied into the sub directory lt PG FP4 install path gt PRM which was created during GUI software setup see CHAPTER 3 SOFTWARE INSTALLATION If no PRM file has been installed before the GUI software will report a fatal error and it will not startup Figure 4 1 Fatal Error No Parameter File Installed ERROR x F302 Unable to find any PAM file Please install PAM files 36 Users Manual U15260EJ4VOUM 4 2 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Starting up the GUI Software System connection After installing the parameter file connect the supplied RS 232C cable or USB cable to the computer in which the PG FP4 is used After connecting the
30. interface connector and HD Sub 25 parallel host connector Change of 7 4 Target Cable Specifications 116 Users Manual U15260EJ4VOUM APPENDIX A REVISION HISTORY 2 2 Third CHAPTER 8 NOTES ON TARGET SYSTEMS Change of example of correct connection regarding RESET signal CHAPTER 8 NOTES ON TARGET SYSTEMS Addition of description about VPP Addition of examples of UART and SIO interface circuits Change of 9 1 SO TxD RESET CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS masasma O CHAPTER 10 ERROR MESSAGES 10 2 GUI Software Fatal Error Messages Addition of F129 F410 F411 F412 and F413 10 3 GUI Software Error Messages Addition of E201 E307 E316 E317 E805 E901 E903 E907 and E908 10 4 GUI Software Information Messages Addition of 1202 1805 1905 1906 1907 1911 1912 1913 1914 1915 1916 1917 and 1918 Fourth Change of Figure 2 1 PG FP4 System Configuration CHAPTER 2 HARDWARE 2 3 8 Target cable INSTALLATION Addition of description about the kind of target cable CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE CHAPTER 4 PG FP4 Addition and change of description OPERATION USING GUI SOFTWARE CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE Change of Figure 7 5 Host Cable Connections CHAPTER 7 Senna of 7 4 Target Cable Specifications CONNECTORS AND CABLES Additions and changes to descriptions in UART and istic interface circuit examples CHAPTER 8 NOTES ON TARGET SYSTEMS Change of
31. menu is displayed only when a single power supply flash memory microcontroller is used 84 User s Manual U15260EJ4VOUM CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE 6 1 4 Voltage Setting menu The Voltage Setting menu is used to check the voltage level setting when programming the target device currently connected to the PG FP4 All the displayed values were set by the parameter file during the last programming session This menu cannot be used to change the settings Voltage Setting gt e Pressing the Next button displays the Utility Misc menu e Pressing the Enter button displays the following commands that can be executed from the Voltage Setting menu e Pressing the Cancel button displays the Commands menu again Vdd J Next button Vvdd2 J Next button Vdd Source J Next button Clk Level J Next button Ser Level J Next button Res Level J Next button HS Level J Next button Vpp Vdd displays the value of Voo supplied to the target device connected to the PG FP4 in volts Vdd2 displays the value of Vpp2 supplied to the target device connected to the PG FP4 in volts Vdd Source indicates the source of Vpp supplied by the target device as either of the following VDD from PG Vbo is supplied from the PG FP4 VDD from device Voo is supplied on the user system Clk Level indicates the voltage level of the clock signal as either of the following VDD VDD2 Ser Level indic
32. of space eiuanons Determining selected communication port speed failed Determining selected communication port number failed Determining selected download port number failed Creating transmit task failed Creating status dialog window failed Download failed Clearing error in receive task failed This occurs when an illegal HEX file or a HEX file that exceeds the FP4 internal memory 1 MB or 2 MB is downloaded Errors F 411 to F 899 indicate severe internal error situations Connection between host and programmer is broken Communication error Connection between host and programmer is broken Reading current cursor handle failed Unknown result of operation Placing command execution time information in status bar failed Unknown command status update Unknown command transmit ended with OK Unknown command transmit ended with unknown answer Unknown command receive timeout Unknown command receive error Unknown command transmit aborted Please stop logging communication first Opening log file failed Creating edit control for communication window failed Creating communication window timer failed Killing monitor timer failed User s Manual U15260EJ4VOUM 109 CHAPTER 10 ERROR MESSAGES F605 Creating communication window subclassing Errors F 411 to F 899 indicate severe internal error procedure failed situations F700 USB splash screen timer failed F750 Please s
33. p the GUI SORWATE scccvis cesses deca hater a aa 37 43 TOOIDAT aiaa a aaah hete rt atc ae a aa aaa aaraa a a a ER 39 AA MENUS eoir a a EEEa a 39 AAT EIE NGN E A S 39 44 2 PVOGFARMIMNICY MeN ssaran ra A A E eee 46 AAS Device mMenu a E T a N 50 44A AGI mMenu israse had sec sascesaheeneadcelSaadadeea asaice sence adbadncasaclseasa Weeateaadanconsaaasaceiaenosaaaaateadededensaanceaete 67 CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE c csseeeeseee 68 CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE ccc cccccesseecesseeesesenseesenseenenneees 79 6 1 PG FP4 Operation Menu siiactiias ets tecwesiis ven eevee cms niethie dean vacewannjeuncevancadseveenuueunsesdasadeeunadeedtsveedavexnedabas 80 Gets Commands MeN essee E 80 6 12 FR Vib Seting MENU ea E a R oleae Seles 82 61 37 Option seting men crre a eee eee 83 6 1 4 Voltage Setting Menu cccccceesceccsseeeceseceeceeeeecsegeecceaeeeceaseesseeeeesaueeessaseeessageeessaneessseseessegeees 85 OKS VUM Se MMC NG sc cans cae eesnseececaedeo a eases ated oe A es ee ho 86 User s Manual U15260EJ4VOUM 9 CHAPTER 7 CONNECTORS AND CABLES snsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn 87 7 1 Power Supply Connector ssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn nnaman mnnn 87 7 2 HD S b 9 Serial Host CONMGCION iins enneunen aaa aa a aa aa aa aa 88 TA Ro 2920 Cabl
34. tab of the device Setup dialog box 1500 Operation completed successfully Executing a command succeeded 1501 This command can only be used for UC2 devices The menu entries Device Write Security and Device Checksum can only be used for UC2 devices 1502 Note Aborting device related commands requires an additional To abort a write erase or verify operation it is Programmer reset necessary to reset the programmer manually 1801 End record not found created The HEX Editor implicitly created an end record when loading a file 1800 Buffer is modified The HEX Editor indicates that its contents are not yet Are you sure to close saved to a disk 1802 The file is modified Save 1804 The file is modified Are you sure to quit 1805 This file is not valid The HEX Editor is attempting to open an invalid file 1905 set is not valid Using most recent settings The SET file format is old prm is not valid Using most recent settings The PRM file format is old 1907 Caution When Chip Erase is disabled chip This is displayed when Disable Chip Erase on Advanced cannot be erased and programmed any more tab of the Device Setup menu is checked 1911 The selection is out of range The value of Speed on the Standard tab of the Device gt Setup menu exceeds the maximum value 1912 The selection is out of range The value of Speed on the Standard tab of the Device Setup menu is smaller than the minimu
35. 102 User s Manual U15260EJ4VOUM CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS 9 3 SI RxD H S The SI RxD input signal must not exceed TTL level voltage Figure 9 3 SI RxD and H S Pins Target System 9 4 CLK Figure 9 4 CLK Pin gt Signal Target system User s Manual U15260EJ4VOUM 103 CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS 9 5 FLMDO FLMD1 Figure 9 5 FLMDO and FLMD1 Pins p gt Signal Target system 9 6 Vbp Vpp2 When Voo and Vopz2 are supplied from the target system the PG FP4 internal voltage regulator is protected Figure 9 6 Voo and Vpp2 Pins Transistor Polyswitch 350 mA Vpp V pp2 eA gt 5 5 generator A D input Target system 104 User s Manual U15260EJ4VOUM CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS 9 7 Vpp Figure 9 7 Vpp Pin Transistor Polyswitch 350 mA A D input User s Manual U15260EJ4VOUM Target system 105 CHAPTER 10 ERROR MESSAGES The PG FP4 error and warning messages are displayed on the message display 10 1 Error Messages of PG FP4 in Standalone Mode N Error Condition Possible Workaround z 001 Invalid PRM data PRM data is invalid The parameter file includes invalid data or the file is incomplete Re set using the parameter file downloaded from the following URL http www necel com micro ods eng index htm Not supported The command issued is not supported on the device and thus cannot be used Command
36. 253 8311 J04 1 General Precautions on Handling This Product Circumstances not covered by product guarantee e f the product was disassembled altered or repaired by the customer e f it was dropped broken or given another strong shock e Use at overvoltage use outside guaranteed temperature range storing outside guaranteed temperature range e f power was turned on while the AC adapter USB interface cable or connection to the target system was in an unsatisfactory state e If the cable of the AC adapter the USB interface cable the emulation probe or the like was bent or pulled excessively e f an AC adapter other than the supplied product was used e f the product got wet e If GND of this product was not connect to GND of the target system e f a connector or cable was connected or disconnected while power was being supplied to the product e f an excessive load was applied to a connector or cable Safety precautions e If used for a long time the product may become hot 50 to 60 C Be careful of low temperature burns and other dangers due to the product becoming hot e Be careful of electrical shock There is a danger of electrical shock if the product is used as described above in 1 Circumstances not covered by product guarantee Users Manual U15260EJ4VOUM Target Readers Purpose Organization How to Read This Manual Conventions PREFACE This manual is intended for users who use the PG FP4 when desi
37. ATION Figure 3 19 Locate File Window a Mi Documents My Computer Cancel Select usbiowiz inf in the drivers directory created under the PG FP4 install directory and click Open The specified location is shown in the window used to specify the copy source of the USB driver file File name usbiowiz int Miu Network F T T Files of type Setup Information mF Figure 3 20 Window for Specifying Driver Files to Be Copied 2 Found New Hardware Wizard x Insert the manufacturer s installation disk into the drive OK SS selected and then click OF _oK Cancel Copy manufacturer s files frome E Progranm Files MECT oolss2 PG FP4 drivers r When you click OK the driver file will be searched The driver file search window is displayed User s Manual U15260EJ4VOUM 31 CHAPTER 3 SOFTWARE INSTALLATION Figure 3 21 Driver Files Search Results Window Found New Hardware Wizard 7 Driver Files Search Hesults The wizard has finished searching for driver files for Your hardware device The wizard found a driver for the following device oy USB Device Windows found a driver for this device To install the driver Windows found click Next c pragram files nectools324p9 fpd drivers usbicwviz int Cancel Click Next gt to start installation When the installation is complete the following window will be displayed Figure 3 22 Completing t
38. After Installation NEC Tools32 joj Opens the README file for the PG FP4 File Edt View Help A Pt3 F P4 Read trie PG FP4Help PG FP4 Starts the PG FP4 GUI software Readme Tr Pa F P4 D Starts the PG FP4 online help Pia FR4 Help 46 object s A ny Uninstalls the PG FP4 from the computer Pia F P4 unhat User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALLATION The setup program installs following files on your hard disk C NECTo0o1lS32 PG FP4 README TXT Latest information FP4 EXE GUI software FP4 HLP Online help file FP4 CNT Online help contents file FP4COM DLL Communication DLL C NECTools32 PG FP4 drivers USBIOWIZ INF Setup information file for OS USBIO SYS USB driver C NECTools32 PG FP4 prm lt empty gt Storage place for parameter file for target device C NECToo1sS32 PG FP4 set lt empty gt Storage place for customized setup files Caution The parameter file for the target device must be downloaded separately from the NEC Electronics Website at http www necl com micro ods eng index html 3 1 2 USB driver installation When the PG FP4 is connected via the USB interface for the first time Windows 98 Windows Me Windows 2000 and Windows XP automatically detect the PG FP4 Then the wizard for searching the new hardware will start Caution USB support is not available on Windows 95 and Windows NT Figure 3 14 When Connection of PG FP4 to USB Port Is Detected
39. DWARE INSTALLATION 2 3 USB port The USB port conforms to Rev 1 1 It Supports a communication speed of 12 Mbps on a USB type B connector Caution USB support is not available on Windows 95 and Windows NT 2 3 8 Target cable The target cable is compatible with the FA adapters of Naito Densei Machida Mfg Co Ltd There are two types of target cables type A 16 pins which is used for both single and two power supply flash memories and type B 10 pins which is a dedicated cable for two power supply flash memories For detailed specifications of the target cable refer to CHAPTER 7 CONNECTORS AND CABLES 2 3 9 IC adapter The SI and SO pins of the PG FP4 must be shorted on the target board when the I C communication mode is used Figure 2 5 Connection Diagram Target board Target device When using an IC adapter the SI and SO pins do not have to be shorted on the target board Figure 2 6 C Adapter CN2 16 pins Pins 3 to 5 shorted CN1 10 pins Pins 3 to 5 shorted User s Manual U15260EJ4VOUM 17 18 CHAPTER 2 HARDWARE INSTALLATION Figure 2 7 Connection Diagram When Using IC Adapter Target board PG FP4 ae adapter Target device lt Usage when writing two power supply flash memory microcontroller gt lt 1 gt Connect the FA adapter and the type B target connector of the target cable 10 pins lt 2 gt Connect the type A target connector 16 pins and the IC adapter CN2 of the target cable
40. ET SYSTEM INTERFACE CIRCUITS 4 If the pins of the PG FP4 s input signals SI RxD H S RESET are processed pull up or pull down with a resistor value in compliance with the specifications loH IOL of the target device referring to CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS 100 User s Manual U15260EJ4VOUM CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS This chapter describes the target system interface circuits of the PG FP4 TTL level 9 1 SO TxD RESET For programming flash memory devices Voo and Vpp2 may be supplied by the PG FP4 When Vpop and Vpp2 are supplied by the target system the PG FP4 internal voltage regulator is protected so that user Vpop and Vppz will not affect the signal lines SO TxD and RESET In either case the signal lines SO TxD and RESET will have TTL level voltage Figure 9 1 SO TxD and RESET Pins Voo generator Vop2 generator 74LV125 gt Signal Target system User s Manual U15260EJ4VOUM 101 CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS 9 2 SCK For programming flash memory devices Voo and Vpp2 may be supplied by the PG FP4 When Vpp and Vpp2 are supplied by the target system the PG FP4 internal voltage regulator is protected so that user Vono and Vpbpz will not affect the signal line SCK In either case the signal line SCK will have TTL level voltage Figure 9 2 SCK Pin Voo generator 4LV125 ki Voo 9 74LV125 74LV125 PG FP4 Target system
41. Figure 9 2 SCK Pin CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS 10 1 Error Messages of PG FP4 in Standalone Mode CHAPTER 10 ERROR Change of 001 Addition of 009 MESSAGES 10 2 GUI Software Fatal Error Messages Change of F410 Change of Figure 5 4 Figure 5 5 Figure 5 10 Figure 5 11 Figure 5 13 Figure 5 14 Users Manual U15260EJ4VOUM 117
42. GUI SOFTWARE OK button The software tries to establish a connection between the PG FP4 and the PC using the selected communication parameters Cancel button Closes the window without making any changes 2 Logging menu The Logging menu opens the log file dialog box to select the log file name The log file will store the communication between the PC and the PG FP4 data in the communication log window Figure 4 14 lt Log File gt Dialog Box Look in 4 Gui Files of type Text File tet Cancel Once logging is enabled a check mark in the Logging menu indicates that logging is active Selecting the menu again will close the log file and stop any further communication logging 3 Select Programming area menu This menu item allows selection of one out of two different programming areas of the PG FP4 1 MB each This menu is valid when Enable two Program Areas on the Advanced tab of Device gt Setup menu is checked Figure 4 15 Programming Area Selection Programming Area 4rea to be used fo Cancel The PG FP4 internal memory area is split into two independent memory areas of 1 MB each of which may hold two different application programs for flash programming When opening this dialog box the current programming area selection will be displayed User s Manual U15260EJ4VOUM 47 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 4 Reset menu By
43. HD SUB 15 male Type A Figure 7 9 Pin Configuration of HD SUB 15 11 1 15 5 10 Figure 7 10 Target Connector Outline View from Socket Side its s 7 o ntishs 2ta elsfrofi2 raie Type A Type B 90 User s Manual U15260EJ4VOUM CHAPTER 7 CONNECTORS AND CABLES Table 7 3 Pin Configuration of Target Connector PG FP4 Side Connector Target Connector Target Connector of PG FP4 HD SUB 15 Male Type A Signal 16 Pin Type B Signal 10 Pin y o s a S a ww ko w d A y e o m E a A e d E ex o ooo o S e S e w e a To o O e a T T w E a T e o wo e o a Nouse ooo S s S o SS SSS Remark For both single and two For two power supply flash power supply flash memories memory Connecting the following connectors as target connectors type A and type B is recommended Type A 16 pin 7616 5002SC Sumitomo 3M Limited Type B 10 pin FAP 10 08 2 OBF Yamaichi Electronics Co Ltd When using a self made cable because the supplied cable cannot be used due to the specifications of the target the cable length should be the same or shorter than the supplied cable Also the frequency characteristics of the cable material should be the same or higher than those of the supplied cable Note that communication may be performed at high speed according to the communication settings Therefore when a cable other than the supplied cable is used the system may not operate normally due to communication errors User s
44. Invalid Valid Valid Valid cluster reprogramming Note1 Since the Erase command is invalid the data that differs from the data already written in the flash memory cannot be written 2 Valid only for an area not specified as the boot area lt 4 gt Program download upload The PG FP4 has 2 MB of flash memory as a user program area This memory area can be used as a single 2 MB area or as two independent 1 MB areas Area 0 and Area 1 Different user programs can be downloaded to Area O and Area 1 and it can be selected which of the programs is to be written to the target device Figure 4 32 Setup Window Program Download Upload Program download upload Enable two Program Areas Enable two Program Areas check box If this check box is not checked one 2 MB memory area is used as the user program area If it is checked one of two independent 1 MB memory areas Area O and Area 1 are used as the user program area For which area is to be used refer to the Programmer Select Programming area menu If a user program that exceeds 1 MB is downloaded the error message F410 Download failed appears Users Manual U15260EJ4VOUM 65 66 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE lt 5 gt Boot block cluster setting The Boot block cluster setting is used to specify the boot area This function is valid only when a single power supply flash memory microcontroller is used The specified boot a
45. Manual U15260EJ4VOUM 91 CHAPTER 7 CONNECTORS AND CABLES 7 5 Parallel Host Connector The parallel host connector can be configured as a centronics interface or as remote control port Depending on the selection one of the following signal settings is available Figure 7 11 HD Sub 25 Parallel Host Connector Figure 7 12 Pin Configuration of HD Sub 25 Parallel Host Connector 13 1 as E S gel co J Table 7 4 Pin Configuration of HD Sub 25 Parallel Host Connector r oe oe Cow o on o Co e o Cos oe o Cow o o Co o Co oe o ess or e ee 92 User s Manual U15260EJ4VOUM CHAPTER 7 CONNECTORS AND CABLES 7 6 USB Port The USB port connection Rev 1 1 allows data transmission up to 12 Mbps on a USB type B connector Figure 7 13 USB Port Connector User s Manual U15260EJ4VOUM 93 CHAPTER 8 NOTES ON TARGET SYSTEMS This chapter explains the basic notes on the target system for rewriting the flash memory in the microcontroller using the PG FP4 CPU Pin Design Proposal RESET Do not connect the RESET signal generator on the target system to the RESET signal of the PG FP4 Otherwise a signal conflict will occur To avoid the conflict isolate the RESET signal generator from the RESET signal of the PG FP4 Do not generate RESET while the PG FP4 is connected This must be especially noted in a system that uses an external watchdog timer
46. To our customers Old Company Name in Catalogs and Other Documents On April 1 2010 NEC Electronics Corporation merged with Renesas Technology Corporation and Renesas Electronics Corporation took over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electronics website http www renesas com April 1 2010 Renesas Electronics Corporation Issued by Renesas Electronics Corporation http www renesas com Send any inquiries to http www renesas com inquiry sCENESAS 8 10 11 12 Notice All information included in this document is current as of the date this document is issued Such information however is subject to change without any prior notice Before purchasing or using any Renesas Electronics products listed herein please confirm the latest product information with a Renesas Electronics sales office Also please pay regular and careful attention to additional and different information to be disclosed by Renesas Electronics such as that disclosed through our website Renesas Electronics does not assume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of Renesas Electronics products or technical information described in this document No license express implied or otherwise is grante
47. UI SOFTWARE 4 3 Toolbar The toolbar contains buttons to start the most important procedures of the PG FP4 Table 4 1 Toolbar Buttons Device Setup button b Device Erase button S File Download button Device Program button File Upload button Device Verify button Sy e Hex Editor button E Device Blank check button E Note Enabled only for single power supply flash memory microcontrollers Device Erase Program Verify Autoprocedure EPV button A 3 Ww Programmer Select Programming area button 4 4 Menus Depending on the actual device status or device type some menu items may be enabled or disabled For example the Device Blank check button is enabled only for single power supply flash memory microcontrollers 4 4 1 File menu After clicking the File menu the following pull down menu is displayed Commands related to file operation appear here Figure 4 4 File Menu Programmer Device Help Hex Editor JI Download Upload Checksum Quit User s Manual U15260EJ4VOUM 39 40 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 1 Hex Editor menu The Hex Editor menu allows you to edit a program file in Intel HEX file format or Motorola S Record format A HEX Editor window opens and the file to be edited can be specified in a file open Figure 4 5 HEX E
48. aborted Command aborted Power failure Abnormal VDD current An overcurrent was detected when VDD was output Check the connection with the device Read Sig failed Reading device signature failed Check if the correct device is selected Check connection Check connection The PG FP4 cannot establish connection to the target device 005 011 012 This might be due to wrong connections between device and the PG FP4 bad socket contacts or non working oscillator Addr Range err Address range error The address given in the command exceeds the device s address range Inv Sig ID Check if the correct device is selected Check if the correct device is selected Check if the correct device is selected Check if the correct device is selected Invalid device name Check if the correct device is selected Inv Signature Invalid signature Check if the correct device is selected Prewrite Timeout Prewrite timeout Communication problem between the PG FP4 and the target device Try the operation again Erase Timeout Erase timeout Communication problem between the PG FP4 and the target device Try the operation again Erase time exceeded A device defect is most probably causing this error Ers Timeset err Erase timeset error The parameter file may contain invalid data Contact NEC Electronics Bln Timeout Blank check timeout Communication problem between the PG FP4 and the target device Try the operation again Blankchk faile
49. ar F Cancel Here you can change the destination path Click to accept the changes or click to undo the changes You will return to the Installation start window refer to Figure 3 7 When the folder window is closed click the button in the installation start window The setup procedure opens the Select Program Folder window By default the program group NEC Tools32 will be created for the PG FP4 program folder You may change the folder name by selecting one of the existing folders or by typing a new folder name in the edit field 24 User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALLATION Figure 3 9 Select Program Folder Window Setup Select Program Folder Please select a program folder Setup will add program icons to the Prograrn Folder listed below fou may type a new folder name or select one from the existing folders list Click Next to continue Existing Folders Developer 2000 for NT Elektronischer AS Katalog Fait ISA Spstems H Lotus Applications MOLTI 2000 Mips v2 0 HEC MEC Tools Select the correct folder and click the button to show a summary of the selected folder Figure 3 10 Start Copying Files Window Ea lt Start Copying Files oe crash Review settings before copying files Setup has enough information to start copying the program files fF vou want to review or change any settings click Back IF vou are satisfied with the settings click Next to beg
50. are product provided with this ULA which includes computer software and may include associated media printed materials and online files or data By installing copying or othenwise using Do you accept all the terms of the preceding License Agreement IF you choose Mot accepted the setup will close To install PG FP4 you must accept thie agreement InstallShield lt Back Accepted Not accepted Click Accepted to continue the installation If you click Not accepted the installation procedure will terminate User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALLATION The installation start window appears Figure 3 7 Installation Start Window Choose Destination Location Select folder where Setup wall install files Fieetre Seale Gl You can exit the installation by clicking the button Click the button to change the installation destination path Click the button to proceed to the Setup Program Folder selection When the button is clicked the Choose Folder window appears User s Manual U15260EJ4VOUM 23 CHAPTER 3 SOFTWARE INSTALLATION Figure 3 8 Choose Folder Window Choose Folder Ea Please choose the installation folder Path C Program Files MECT ools324PG FP Directories Et Program Files H Accessories E Adobe 1 Common Files _ H InstallShield Installation Informnatior H A Intemet Explorer bee of Messenger i Microsoft Exchange
51. as thick and as short as possible Insert neither capacitors nor resistors into the Vpr line unless otherwise stated Note that when pull down resistors are needed due to the specifications of the target the resistor value must be 470 Q or higher Incorrect circuit PG FP4 VPP PG FP4 Vee Others For the unused pins refer to the user s manual of the device Some devices have pins that must be processed differently For these pins also refer to the user s manual of the device Example of pins processed differently MODE CKSEL REGOUT REGIN etc 96 User s Manual U15260EJ4VOUM CHAPTER 8 NOTES ON TARGET SYSTEMS The following show examples of the interface circuits of UART asynchronous communication port and SIO 3 wire clocked communication port Refer to the above design proposal for the pin processing of the device to be used e Using two power supply flash memory microcontroller Figure 8 1 UART Interface Circuit Example R Vcc 1 kQ Microcontroller JUMPER Caution1 Insert neither capacitors nor resistors into the Vpr line unless otherwise stated When pull down resistors are inserted into the Vpr line the resistor value must be 470 Q or higher 2 The PG FP4 generally performs normally without pin processing 3 If the pins of the PG FP4 s output signals SO TxD are processed pull up or pull down with a resistor value in compliance with the specifications VIH VIL of the target device referri
52. ata is transmitted from the programmer and verified against the data written to the flash memory off After execution of the Program and EPV commands the data transmitted from the programmer is not verified against the data written to the flash memory J Next button SCF after PRG Displays the set status of the command option Security flag after Program as either of the following on After execution of the Program and EPV commands the security flag selected by Security flag settings is automatically set off After execution of the Program and EPV commands the security flag is not automatically set J Next button SUM after PRG Displays the set status of the command option Checksum after Program as either of the following on After execution of the Program and EPV commands the flash memory checksum value of the target device is read from the target device and displayed on the programmer off After execution of the Program and EPV command the flash memory checksum value of the target device is neither read nor displayed J Next button continued on next page Note This menu is displayed only when a single power supply flash memory microcontroller is used User s Manual U15260EJ4VOUM 83 Prog Area J Next button Chip ERS dis J Next button Block ERS dis J Next button Block PRG dis J Next button dis PRG Blk gt J Next button dis ERS Blk gt CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE Disp
53. ates the voltage level of the serial communication signal The high level of the serial communication signal is indicated as either of the following VDD VDD2 Res Level indicates the voltage level of the reset signal The high level of the reset signal is indicated as either of the following VDD VDD2 HS Level indicates the voltage level of the handshake signal The high level of the handshake signal is indicated as either of the following VDD VDD2 Vpp indicates the value of Ver supplied to the target device connected to the PG FP4 in volts User s Manual U15260EJ4VOUM 85 CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE 6 1 5 Utility Misc menu The Utility Misc menu is used to check the F W version of the PG FP4 and the version of the parameter file downloaded It is also used to execute RESET of the PG FP4 This menu cannot be used to change settings Utility Misc gt e Pressing the Next button displays the Commands menu e Pressing the Enter button displays the following commands that can be executed on the Utility Misc menu e Pressing the Cancel button displays the Commands menu Reset PG FP4 gt When the Enter button is pressed next the programmer is reset J Next button PG FP4 F W Version PG FP4 F W Version displays the firmware version number of the PG FP4 Display example PG FP4 F W Version V1 16 J Next button PRM Name PRM Name displays the file name of the parameter file stored in the PG
54. ation and application examples The incorporation of these circuits software and information in the design of a customer s equipment shall be done under the full responsibility of the customer NEC Electronics assumes no responsibility for any losses incurred by customers or third parties arising from the use of these circuits software and information e While NEC Electronics endeavors to enhance the quality reliability and safety of NEC Electronics products customers agree and acknowledge that the possibility of defects thereof cannot be eliminated entirely To minimize risks of damage to property or injury including death to persons arising from defects in NEC Electronics products customers must incorporate sufficient safety measures in their design such as redundancy fire containment and anti failure features e NEC Electronics products are classified into the following three quality grades Standard Special and Specific The Specific quality grade applies only to NEC Electronics products developed based on a customer designated quality assurance program for a specific application The recommended applications of an NEC Electronics product depend on its quality grade as indicated below Customers must check the quality grade of each NEC Electronics product before using it in a particular application Standard Computers office equipment communications equipment test and measurement equipment audio and visual equipment home
55. ation problem between the PG FP4 and the target device Try the operation again 093 SUM Comm err Device communication error Communication problem between the PG FP4 and the target device Try the operation again 094 SCF Comm err Device communication error Communication problem between the PG FP4 and the target device Try the operation again 095 EXR Comm err Device communication error Communication problem between the PG FP4 and the target device Try the operation again EXW Comm err Device communication error Communication problem between the PG FP4 and the target device Try the operation again User s Manual U15260EJ4VOUM 107 CHAPTER 10 ERROR MESSAGES 10 2 GUI Software Fatal Error Messages GUI software fatal error messages indicate a severe error that destabilizes the GUI software operation When the problem persists after restarting the GUI software please contact NEC Electronics Errors F 100 to F 409 indicate severe internal error communication to the programmer F126 Creating communication setup dialog window failed F127 Creating program area selection dialog window failed 108 User s Manual U15260EJ4VOUM F300 F301 F302 F303 F304 F407 F408 F409 F410 F411 F412 F413 F500 F501 F502 F503 F504 F505 F506 F507 F508 F600 F601 F602 F603 F604 CHAPTER 10 ERROR MESSAGES Creating splash screen timer failed Errors F 100 to F 409 indicate severe internal error Edit control out
56. by the parameter file in volts V The signal levels cannot be changed Command options This dialog box is used to specify the options of the PG FP4 flash processing commands Figure 4 30 Setup Window Command Options Command options T Blank check before Erase Read verify after Program T Security flag after Program Checksum after Program Blank check before Erase check box If this check box is checked a blank check is performed before execution of the Erase and EPV commands If the result of the blank check is OK erase processing is not executed This option can be specified only when a single power supply flash memory microcontroller is used Read verify after Program check box If this check box is checked write data is transmitted from the programmer after execution of the Program and EPV commands and verified against the data written to the flash memory Security flag after Program check box If this check box is checked automatic programming of the selected security flag is executed after execution of the Program and EPV commands This option can be specified only when a single power supply flash memory microcontroller is used Checksum after Program check box If this check box is checked the flash memory checksum value of the target device is read from the target device and displayed on the programmer after execution of the Program and EPV commands This option can be spec
57. ce connected to the PG FP4 When View is selected from the Read menu 4 KB read data is displayed in the log window each time the Enter key is pressed When Write Intel HEX File or Write Motorola SREC File is selected from the Read menu the read data can be saved in the Intel HEX format or Motorola HEX format Security menu The Security command initiates the programming of the security flag of the target device connected to the PG FP4 Setting of the security flag is specified by Security flag settings on the Advanced tab of the Device gt Setup menu Caution The security command can be specified only when a single power supply flash memory microcontroller is used Checksum menu The Checksum command initiates the reading of the checksum value of the target device connected to the PG FP4 The checksum value in the flash memory area selected in Operation Mode on the Standard tab of the Device gt Setup menu is read Users Manual U15260EJ4VOUM 51 52 8 9 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Caution The Checksum command is available only when using a single power supply flash memory microcontroller or two power supply flash memory microcontroller that supports the Checksum command Autoprocedure EPV menu N The EPV command compares the checksum value when the user program is downloaded with the checksum value in the user program area of the PG FP4 subject to EPV If the two values are the
58. ct a mode With some devices the number starts from ch1 In this case chO of the parameter on the screen equals ch1 of the device and the displayed channel number must be shifted accordingly Note When using a single power supply flash memory microcontroller Item on Screen Description SIO chO SIO 3 wire clocked communication port channel 0 SIO ch1 SIO 3 wire clocked communication port channel 1 SIO ch2 SIO 3 wire clocked communication port channel 2 SIO H S SIO 3 wire clocked communication port with handshake IIC chO IC channel 0 IIC ch1 IC channel 1 IIC ch2 IC channel 2 IIC ch3 IC channel 3 UART ch0 UART asynchronous communication port channel 0 UART ch1 UART asynchronous communication port channel 1 UART ch2 UART asynchronous communication port channel 2 UART ch3 UART asynchronous communication port channel 3 Port chO Port pseudo 3 wire A Port ch1 Port pseudo 3 wire B Port ch2 Port pseudo 3 wire C Users Manual U15260EJ4VOUM 57 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Pulse number Displays the number of Ver or FLMDO pulses corresponding to the selected communication mode Speed list box Select the communication rate of the selected communication channel from the following lt When SIO chO SlO ch1 SIO ch2 or SIO H S is selected gt 2 4 kHz 9 8 kHz 39 kHz 156 kHz 625 kHz 2 500 kHz lt When IIC chO IIC ch1 IIC ch2 or IIC ch3 is selected gt 10 k baud 20 k baud 50 k baud 100 k baud
59. d Blank check failed The device connected is not empty Use the erase command before programming 06 User s Manual U15260EJ4VOUM 013 020 021 022 023 024 025 030 032 040 041 042 043 050 51 0 b CHAPTER 10 ERROR MESSAGES e e mea the target device Try the operation again 063 Wrb Timeset err Writeback timeset error The parameter file may contain invalid data Contact NEC Electronics 070 Write timeout Write timeout Communication problem between the PG FP4 and the target device Try the operation again 071 Write failed The write operation failed Either the device was not blank before writing or a device defect is causing this error 072 Write retry err Write retry error Either the device was not blank before writing or device defect is causing this error 073 Wrt Timeset err Write timeset error The parameter file may contain invalid data Contact NEC Electronics 080 Vrf Timeout Verify timeout Communication problem between PG FP4 and the target device Try the operation again 081 Verify failed Verify failed The data in the target device s flash memory is not the same as in the PG FP4 IVrf Timeout Internal verify timeout Communication problem between the PG FP4 and the target device Try the operation again 091 IVerify failed Internal verify error An error has occurred while the write data level is checked Erase and write the device again 092 VGT Comm err Device communication error Communic
60. d hereby under any patents copyrights or other intellectual property rights of Renesas Electronics or others You should not alter modify copy or otherwise misappropriate any Renesas Electronics product whether in whole or in part Descriptions of circuits software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples You are fully responsible for the incorporation of these circuits software and information in the design of your equipment Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits software or information When exporting the products or technology described in this document you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations You should not use Renesas Electronics products or the technology described in this document for any purpose relating to military applications or use by the military including but not limited to the development of weapons of mass destruction Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture use or sale is prohibited under any applicable domestic or foreign laws or regulations Renesas Electronics has used reasonable care in preparing the information included in this document but R
61. de of the task bar also terminates the PG FP4 GUI software User settings are saved in the FP4 INI file so that the GUI software will start up next time with the same settings 4 4 2 Programmer menu Clicking the Programmer menu displays the following pull down menu This pull down menu consists of program setting commands Figure 4 12 Programmer Menu Fal FP File Programmer Device Help netup host connection Logging elect Frogramming area gt yver Peset Update Firmware 1 Setup Host Connection menu The channel for communicating between the PG FP4 and PC can be selected and set in this dialog box Figure 4 13 lt Host Connection gt Dialog Box Host Connection oS e se oe F Serial Port COM2 kaai Baud 3600 Use parallel Download Fort LPTs You may select USB as the communication channel if USB is supported on your PC If Serial is selected the port and baud rate may be selected from the drop down list boxes Use parallel Download can be selected in addition to the serial port If parallel download is selected data download to the PG FP4 is performed via the selected parallel interface Caution The parallel interface cable is not part of the PG FP4 package Check that the LPTx port is not used before using the parallel port USB communication is not supported on Windows 95 or Windows NT 46 User s Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING
62. directory names are saved in the FileDownloadDirectory key in the Programmer section in the FP4 INI file The downloaded file names are saved in the FileDownFileName key in the Programmer section in the FP4 INI file Erase memory before download can be used to select whether to erase the internal memory of FP4 before a new program is downloaded User s Manual U15260EJ4VOUM 43 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 3 Upload menu gi The Upload menu allows you to specify and upload a program file from the PG FP4 flash memory to the host machine Figure 4 9 File Selection Window for Program Upload Look in EJ Gui ro application hes Files of type Intel Hex files hex Cancel Range hex Start E End FF In the appearing window you can e Select a program file for upload e Select the upload file format Intel HEX or Motorola S Record format e Select the memory start and end addresses to upload The most recently used directory from which a file has been uploaded will be shown in the Upload menu Open button Press lt return gt to start continue output appears in the Communication Log window when the Open O button is clicked Click the Return button to start uploading Cancel button Closes the window without uploading the program 44 User s Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 4 Checksum menu The C
63. ditor File Open Window Look in EJ Gui my application hes Files of type HEX Files HE Cancel File name my_application hex HEX Files or SREC Files may be selected from the Files of type list box Users Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE After selecting a file to open the HEX Editor main window loads the file and displays its contents as follows Figure 4 6 HEX Editor Main Window W HexEditor D C monitor hex File address 0 1 2 3 4 5 6 7 8 9 B C D E F 6123456 89ARCDEF HHG088 86 H6 FF FF FA 62 F 82 68 83 GB BS GF 83 16 BF 8686610 1D 83 24 83 2B 83 32 83 39 83 4O 83 47 O39 SE 83 2 9 6 N 8686020 55 83 5C 63 63 63 6A 63 FF FF FF FF FF FF FF FF I U c j 886636 FF FF FF FF FF FF FF FF FF FF FF FF FF FF 71 83 q HH6604580 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF HH6058 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF HH6068 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF HH6670 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF GHHG EE 102 DE FE 13 FB 88 13 F4 64 13 FA CO 31 27 O p u 1 HH6090 AF 31 37 86 8S J AA 18 86 ES DO AT B OY EG 1 a HH60AH EA FF F7 E 86 BD FF 96 44 8118 6B FE 99 10 EG ED pi HHBHBH 82 8H E 22 B1 AT 82 96 OY 16
64. e ChOSSCG aia a Ea E 88 7 3 HD Sub 15 Target Interface Connector sssssnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnmnnnnnnn nnn 89 iA Target Cable SpeciiicatiOns sisson anaes aa arsa a anoa aanraai aaa SAna idia Na 90 7 5 Parallel HHOStGONMGCION ases red ete ecewssieneeeeled eee tienen eels 92 TO USB POW ya ces tect erste scout a a atoeeet ade TA E sane 93 CHAPTER 8 NOTES ON TARGET SYSTEMS sscccccccsssnnssseeeeceeeecnnssseeeeeeeeeconssseeeeseeseconess 94 CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS ccccseeeesseesesssseeeeeeeeeeensneeeeeeseeneennees 101 Ol SOFT XD RESET riyan a a a 101 92 OOR a E E ONS 102 93 SID H S ai a a a aa aiaa aaao 103 94 CEK zornan a T a ees 103 95 FEMDO FLMD T ionuca aaa aaa ana aa a aaaea aaa aaa EAN 104 SiG VDD DI irem nia E AEE EEEE EEE E AEE AEE E EEO 104 AP NMPP anaana O EA OAT 105 CHAPTER 10 ERROR MESSAGES sirsie EN 106 10 1 Error Messages of PG FP4 in Standalone Mode cccccccsessseeeeeeeenseeeseeeenseeesenenaneeesees 106 10 2 GUI Software Fatal Error Messages cccsscsseeeeessseeeeeesseeeeeeensseeeeeeeesseeeeeoeesseeeseoenaseessons 108 10 3 GUI Software Error MESSAGES eivisiivcsesesieedste rice nda tsceesesevevceesezedeeansnendwecssnisveewaaaudeepennisnedens 111 10 4 GUI Software Information Messages ccccccceesseeeeceenseeeeeeesseeeeseoenseeeseeesseeeesoeesseessoeaas 114 APPENDIX A REVISION HISTORY noai
65. e PG FP4 Europe the UK the USA and Japan and connect it to the AC adapter to configure a PG FP4 power supply unit lt 3 gt Connect the PG FP4 power supply unit to the PG FP4 and the main power supply User s Manual U15260EJ4VOUM CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE Starting system lt 1 gt Turn on the switch of the power supply unit cable Do not connect the FA adapter before turning on the switch Confirm that the Status LED of the PG FP4 remains dark and that Commands gt is displayed on the LCD indicating that the PG FP4 is ready for operation If this does not happen the chances are the PG FP4 is faulty Consult an NEC Electronics sales representative or distributor lt 2 gt Connect the PG FP4 to the FA adapter with the target cable Note This is a product of Naito Densei Machida Mfg Co Ltd lt 3 gt Start the GUI software The GUI software tries to establish a connection with the PG FP4 at 9 600 bps using COM1 If it is not successful it scans other communication rates and ports In this example it is assumed that the PG FP4 is connected to COM1 Figure 5 1 Connection Between GUI Software and PG FP4 Trying to connect COM with 9600 Baud ln Operation lt 4 gt You may click the ABORT button and select the communication port from the Programmer Setup host connection menu directly Figure 5 2 Setup host connection Menu File Programmer Device H
66. e command menu is displayed on the message display and the result of executing a command is indicated by the message display and status LED The command menu consists of two levels of menus a main menu and sub menu The Next button is used to display the next menu of the same level The Enter button selects or executes the menu item currently displayed The Cancel button aborts the command under execution and restores the previous menu level Figure 6 1 Menu Status Transition by Key Input Main menu Sub menu Enter button Commands Type Setting X_ Cancel button Type Setting Option Setting Option Setting Voltage Setting Voltage Setting Utility Misc Utility Misc Next button Enter button Reset FP4 Command execution Next button On the main menu level the PG FP4 will show the menu items that can be selected On the sub menu level the first line in the message display shows the menu item and the second line shows the response from the PG FP4 if any User s Manual U15260EJ4VOUM 79 CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE A command prompt gt displayed at the end of a menu line indicates that the menu can be selected by the Enter button or that the menu command can be executed If the command prompt gt is not displayed at the end of a menu line it means that the function is only display
67. e format cannot be changed with this selection Users Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 2 Download menu ca The Download menu allows you to select and download a program file into the PG FP4 flash memory The downloaded program file may be programmed into the device s flash memory by executing the Program command or EPV command Figure 4 8 File Selection Window for Program Download Select a File to download eunenenone ts a my application hes Files of type S tec Hex files rec s2 hex Cancel W Erase memory before download The most recently used directory from which a file has been downloaded will be offered in this window as the default selection After downloading the user program the checksum in the flash memory area of the PG FP4 valid in Progarea is calculated and the result is displayed in the programmer parameter window and communication log window Open button Downloads the selected user program to the flash memory of the PG FP4 Checksum data of the downloaded data is saved in the FileDownCrcSum key in the Programmer section in the FP4 INI file This saved checksum data is used for comparison with the PG FP4 memory contents before executing the EPV command The downloaded user program is retained even after the power of the PG FP4 is switched off Cancel button Closes the window without downloading the selected user program The
68. e procedure for the target device connected to the PG FP4 While erasing the contents in the flash memory is in progress the progress is displayed in the communication log window indicating the operation of the programmer When a two power supply flash memory microcontroller is used check the target device with the Blank Check command before executing the Erase command If the device is already blank the Erase command is not executed When a single power supply flash memory microcontroller is used the Blank Check command that is executed before the Erase command is executed in accordance with the setting of Command options on the Advanced tab of the Device gt Setup menu You may abort the erase procedure by pressing the Cancel button on the PG FP4 After completing the Erase command the GUI software displays the target device command execution result 50 User s Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 3 Program menu 4 5 6 7 tL The Program command transmits the memory contents user program in the active programming area 0 or 1 of the PG FP4 and writes them to the flash memory In addition it also executes verification to check if the write level is secured after the user program has been written After execution of the Program command Verify which detects a communication error of the user program while it is being transmitted from the PG FP4 to the target d
69. ed When power to the PG FP4 is turned on the following message is displayed on the message display with the status LED remaining dark Commands gt The status LED indicates the status of communication with the device and the result of execution as follows Status LED Status The selected command is under execution Orange The details of the execution status will be displayed on the message display O The selected command has been executed correctly Green The command that has been correctly executed will be displayed on the message display R The selected command has been terminated by an error Red The details of the error will be displayed on the message display 6 1 PG FP4 Operation Menu In the standalone mode the writing environment of the target device can be checked and rewritten by using the commands explained in this section 6 1 1 Commands menu The Commands menu offers various commands necessary for rewriting the target device Select a command from this menu and press the Enter button The PG FP4 will then execute the command to the target device For the details of command execution refer to 4 4 3 Device menu Commands gt e Pressing the Next button displays the Type Setting menu e Pressing the Enter button displays the next command of the Commands menu that can be executed e The Cancel button is invalid E P V gt When the Enter button is pressed next the target device connected to the
70. eeeeeeeesseeeseoeesseeseoes 14 2o ROSEOM PU E osista r 14 2 3 2 PG FP4 control panel and CONNECHOSS cccceecccceeeeeeceeeeeeceeeeeeseeeeesaeeeeesaaeeeesaeeeessaeeeesseeeeesaeeeenas 15 20 ANGST SVSUCIN seraa a La dn ccc a ete oe ee 16 2 Se OWN CMR SUPO ciate terete enattadieente tec stone eters ete a eames ete rent erected ede aerosol 16 2 90 MS 2392C NOSE GONMECIOM eneee d Cassese tease termes Eades ans oes sess acess 16 2 9 0 Parallel NOSt COMMCCION lt 5 siese sient th spent oic a a s 16 Zoe UOB DON Gerra ees ete dea ee es ie a ae a a aad ee ee 17 2 950 Target CADIG eine a e ar eara EE EEO 17 239 TO 0 lt 1 0 aa E NT ee een eee 17 CHAPTER 3 SOFTWARE INS TALLA TION sisicaisiaecnanscecavaccincaeeicossaivecataivezatecsasceaseieshcaneccesancscsbaccantectannes 19 St GraphiCal USer IMG aCe ic iaes soc cucciec ered seca ee eeu veteteesiedacanc aus aceweennc ais cone weeds visa enede cand eudans 19 31 1 GUsoffware INStallaliOn lt cascec occaohusse teste E a aeetetnt 19 ak2 USB Griver IMStallatlon ceee a a a aa a OU ee 28 go GUlsotware uninstallation scese nnet annn eaS E Or aaao EAEE RoR aR 33 3 2 Firmware and GUI Software Update Installation ccccessssseeecenseeecennseeeeenseeseeeseeesoees 34 32 Firmware Update installati n ssnin a A E E 35 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE cccccsssseecsssseesceeseeseesneeeseeneeeees 36 AST MTPOGUCTION sipsons 36 42 Starting
71. elp netup host connection Logging elect Frogramming area gt yer Reset Update Firmware lt 5 gt Select the appropriate port number to which the PG FP4 was connected The initial communication speed is set to 9 600 bps factory setting of the PG FP4 User s Manual U15260EJ4VOUM 69 CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE Figure 5 3 Setup Communication Parameters Host Connection oS USE i Serial Port com Baud 175200 Use parallel Downoad Port LPT E lt 6 gt Select to activate the new port settings If the GUI software has been correctly started the following screen is displayed Figure 5 4 GUI Software Initial Screen FP4 Miel x B amp lt JASN Bootloader Version 1 14 Firmware Version V1 30 Device Name OF S025 4 Status autoconmected sotr off Parameter file Parallel port in remote control mode Name 70F32025A PFM DProgare Version W1 03 Active Program Area U noses rautocon on Device Setting file AutoCon is on Name FOF SUC5A set y Date Tue May 11 21 23 38 Download file Prog Area O Connection to device Fart Sl ch Pulse Mum 0 Speed 65000 Vdd 05 00 Supply Freq EEOOOO0 Multiply 5 00 Block Area Address File Checksum Address 70 User s Manual U15260EJ4VOUM CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE Pro
72. enesas Electronics does not warrant that such information is error free Renesas Electronics assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included herein Renesas Electronics products are classified according to the following three quality grades Standard High Quality and Specific The recommended applications for each Renesas Electronics product depends on the product s quality grade as indicated below You must check the quality grade of each Renesas Electronics product before using it in a particular application You may not use any Renesas Electronics product for any application categorized as Specific without the prior written consent of Renesas Electronics Further you may not use any Renesas Electronics product for any application for which it is not intended without the prior written consent of Renesas Electronics Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas Electronics product is Standard unless otherwise expressly specified in a Renesas Electronics data sheets or data books etc Standard Computers office e
73. evice is executed in accordance with the setting of Command options on the Advanced tab of the Device gt Setup menu While programming is in progress the progress is displayed in the communication log window indicating the operation of the programmer This progress indicates the progress of programming the target device as a percentage You may abort the programming procedure by pressing the Cancel button on the PG FP4 After completing the Program command the GUI software displays the target device command execution result Verify menu F The Verify command transmits the memory contents in the active programming area 0 or 1 of the PG FP4 to the target device connected to the PG FP4 and verifies these contents against the data written to the flash memory of the target device This command does not check the write level Use it to check if data communication between the PG FP4 and target device has been correctly performed While the Verify command is being executed the progress is displayed in the communication log window indicating the operation of the programmer This progress indicates the progress of verifying the target device as a percentage You may abort the verification procedure by pressing the Cancel button on the PG FP4 After completing the Verify command the GUI software displays the target device command execution result Read menu The Read menu is used to read the flash memory of the target devi
74. exadecimal format i e figures O 9 and letters A F Any other data will be rejected The ASCII representation if any is shown at the right side of the main window This area is for reference only Data input is not possible in the ASCII window Use the scroll bar to move another address range into the visible area of the HEX Editor The address space shown in the HEX Editor window is limited to 4 MB The following keys can be input using the keyboard Users Manual U15260EJ4VOUM 41 42 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Table 4 2 Key Functions That Can Be Input in HEX Editor Window 0 9 A F Data input Move cursor in right direction If any changes have been made to the edited file the HEX Editor File Save and File Save As ere menu items will be enabled to save the modified data Figure 4 7 HEX Editor lt Save As gt Dialog Box Save I E Gui a my application hes File name my_application Save as type HEX Files HE Cancel Intel HEX C Motorola SREC Previous start address None Start address fo Previous end address Hone End address 3FFFF Besides the file name and directory location lt Save As gt allows selection of a different start address and a different end address for the new file The original start address and end address are offered as the default selection Click the file format button of the format in which to save the data The fil
75. ey will verify e Device availability e Ordering information e Product release schedule e Availability of related technical literature e Development environment specifications for example specifications for third party tools and components host computers power plugs AC supply voltages and so forth e Network requirements In addition trademarks registered trademarks export restrictions and other legal issues may also vary from country to country GLOBAL SUPPORT http www necel com en support support html NEC Electronics America Inc U S Santa Clara California Tel 408 588 6000 800 366 9782 NEC Electronics Europe GmbH Duesseldorf Germany Tel 0211 65030 e Sucursal en Espana Madrid Spain Tel 091 504 27 87 e Succursale Francaise Velizy Villacoublay France Tel 01 30 67 58 00 e Filiale Italiana Milano Italy Tel 02 66 75 41 e Branch The Netherlands Eindhoven The Netherlands Tel 040 244 58 45 e Tyskland Filial Taeby Sweden Tel 08 63 80 820 e United Kingdom Branch Milton Keynes UK Tel 01908 691 133 User s Manual U15260EJ4VOUM NEC Electronics Hong Kong Ltd Hong Kong Tel 2886 9318 NEC Electronics Hong Kong Ltd Seoul Branch Seoul Korea Tel 02 558 3737 NEC Electronics Shanghai Ltd Shanghai P R China Tel 021 5888 5400 NEC Electronics Taiwan Ltd Taipei Taiwan Tel 02 2719 2377 NEC Electronics Singapore Pte Ltd Novena Square Singapore Tel 6
76. flash memory selected under Operation Mode in the Standard Setup menu This setting is cleared by the Erase command when Chip was selected under Operation Mode Disable Program check box If this check box is checked the Program command becomes invalid as does the Erase command in all the blocks of the flash memory selected under Operation Mode in the Standard Setup menu The Erase command for the entire flash memory area is valid This setting is cleared by the Erase command when Chip was selected under the Operation Mode Disable Read check box If this check box is checked the Read command becomes invalid This setting is cleared by the Erase command when Chip was selected under the Operation Mode Users Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Disable Boot block cluster reprogramming check box If this check box is checked the boot area is set regarding the boot block set by the Boot block cluster setting function as the last block Caution Be aware that if the security flag is set in the target device writing to the boot area in the device cannot subsequently be enabled The following is the correspondence between the Erase and Program commands when the security functions of a single power supply flash memory microcontroller are valid CHIP Erase Block Erase Program Command Read Command Command Command Disable Read Read valid valid valid invalid Disable Boot block
77. ftware 1 Read most recent INI file settings Try opening the most recent PC port and send the ver command to the PG If 1 fails try the following twice Open the USB port and send the ver command on Windows 98 and Windows 2000 only Open COM1 COM6 with all possible baud rates and send the ver command for each of these combinations As soon as any of the combinations above succeeds the communication port has been found When serial communication is established and most recently the parallel download port has been used DownloadPort key in INI file Try opening the parallel PC port and send the ctr on command to the PG Users Manual U15260EJ4VOUM 111 CHAPTER 10 ERROR MESSAGES Executing a script file might abort with one of these errors me contents of the line causing the error are also displayed E220 Opening upload file failed E221 Command not allowed in script file E222 Processing a command failed E223 Command execution failed The script syntax was correct and the command has been sent to the PG FP4 but the command execution itself showed an error e g a verify error on the target device Determining download directory failed The selected directory name in the file download dialog box is invalid Determining upload directory failed The selected directory name in the file upload dialog box is invalid Trying to open USB port failed The processing after setting the Programmer Communicat
78. gning and developing a system using an NEC Electronics on chip flash memory microcontroller This manual is intended to give users an understanding of the basic specifications and correct use of the PG FP4 By using the PG FP4 programs can be easily erased from or written to the flash memory of an NEC Electronics on chip flash memory microcontroller or can be verified on Windows screens while the microcontroller is mounted on the user board This manual includes the following sections Overview Hardware installation Software installation PG FP4 operation using GUI software Sample programming session using GUI software PG FP4 operation in standalone mode Connectors and cables Notes on target systems Target system interface circuits Error messages To understand the overall functions and usage of the PG FP4 read this manual in the order of the CONTENTS Be sure to read CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE because this chapter presents important information for using the PG FP4 It is assumed that the readers of this manual have general knowledge of electricity logic circuits and microcontrollers In the explanations of the operation of the applications it is also assumed that the readers have sufficient knowledge of Windows For the usage and terminology of Windows 95 Windows 98 Windows NT Windows Me Windows 2000 and Windows XP refer to each Windows manual The mark shows major revised poi
79. gramming environment setting lt 1 gt Select the menu item Device gt Setup from the menu bar Figure 5 5 Device Setup Menu FP4 Toolbar ye File Frogrammer Device Help ye i CHECK Erase Program Ver oll Bootloader Read Firmvare Yer a sotr off EUT Parallel poo Hecksum E pProgarea a Active Progi Autoprocedure EPY Ucn on C Aa eaaa Autolon 1 e Connect a Signature read eb Seeuniin settings lt 2 gt The dialog box for standard device setup will be activated Figure 5 6 lt Standard Device Setup gt Dialog Box Properties Fx Standard Advanced Device Setting file C Program Files FL PR4SSET New A SET E Saveds POFSO254 PRM Supply oscillator Frequency 6 MHz On Target Hz F Communication imtertace to device Fort S10 ch0 Pulse number p Speed 625kHz IhAdaress iin Multiply rate intemal Direct mode f PLL mode 5 00 Operation Mode i Chip Start j M Selective Ermaanmnna vent Read l Block Ead OOO000 so Show sddess Erd O3FFFF omea a User s Manual U15260EJ4VOUM 71 CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE lt 3 gt Click the button to create a new customized setup file for the wPD70F3025A Figure 5 7 Creating New Customized Setup File Newes Save in Cy Set e j et EJ a 70F3025A s6t File name FOF 30254 6 save as type FP4 setu
80. he Found New Hardware Wizard Window Found New Hardware Wizard a Completing the Found New Hardware Wizard O USBIO Device VID 004C PID 0201 HEC Flash Programmer Windows has finished installing the software for this device To close this wizard click Finish ancel Now that the USB driver has been installed the PG FP4 is ready to communicate using the USB port To complete the installation click Finish 32 User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALLATION 3 1 3 GUI software uninstallation 1 Uninstallation using PG FP4 unlInst icon After all components of the GUI software have been installed clicking the PG FP4 unlnst icon will start the uninstallation procedure W FP F P4 unhat All files installed during setup will be removed from your hard disk except the parameter files PRM and customized setup files SET 2 Uninstallation using Add Remove Programs Start Add Remove Programs in the Windows Control Panel ddi Remove Programs Select PG FP4 in Change or Remove Programs then click Change Remove to start uninstallation Figure 3 23 Add Remove Programs Window eal iene aS Currently installed programs Sort bys Mame Change or am PG FP4 Size S16KB Remove JE Programs Eg Add Remove Programs Used rarely Last Used On 1 14 2003 gt Add New Programs To change this program or remove ik From your
81. he PG FP4 nor are they saved to the customized setup file the current dialog box is just closed However the settings that have already been saved to the customized setup file and downloaded to the PG FP4 are not reset by this button lt 1 gt Device The parameter file holds the set values of the basic parameters necessary for rewriting the flash memory of the target device This file is downloaded along with the customized setup file that saves changes in settings in accordance with the user environment Figure 4 23 Setup Window Device Selection Hew Save Ag Parameter file 70F 30254 PM Defaults Setting file list box Displays the customized setup file saved to lt PG FP4 install path gt SET When using a saved customized setup file select it here button Click this button to specify a customized setup file saved to other than lt PG FP4 install path gt SET Clicking this opens a window for specifying a customized setup file Specify the file and then click the button Save As button Displays a window in which to overwrite the current settings on the device setup window to the existing customized setup file or save them as a new file Defaults button Returns all the displayed settings to the default values of the data in the parameter file PRM User s Manual U15260EJ4VOUM 55 56 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE button Creates a new customi
82. hecksum menu may be used to verify that the PG FP4 s flash memory area contains the correct download file Figure 4 10 Checksum Dialog Box 1 Checksum Programming Area f ERC zum 32 bit Device Area Start 0 Length B0000 C User Defined Start Address 0 Length 100000 All the programming memory area 2 MB or Check Complete Programmer Application Memory in which 32 bit CRC calculations are performed in the PG FP4 programming memory area selected using the Programmer gt Select Programming area menu is selected by default The currently selected programming memory area is displayed in the Programming Area for reference Select the Device Area to calculate the checksum of the flash memory area of the target device The target memory area accords with the information of the currently downloaded parameter file Select User Defined to calculate the checksum of any memory area In this case specify the Start Address and Length The checksum is displayed in the communication log window Figure 4 11 Checksum Dialog Box 2 Checksum Progranmiming 4rea ERE sum 32 bit CRC sum 32 bit Arithmetic checksum 16 bit lication Memory Device Area Start 0 Length 40000 C User Defined Ess 7 User s Manual U15260EJ4VOUM 45 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 5 Quit menu Terminates the PG FP4 GUI software Clicking the button on the right si
83. hines Corporation Windows and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Pentium is a trademark of Intel Corporation e The information in this document is current as of May 2004 The information is subject to change without notice For actual design in refer to the latest publications of NEC Electronics data sheets or data books etc for the most up to date specifications of NEC Electronics products Not all products and or types are available in every country Please check with an NEC Electronics sales representative for availability and additional information e No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Electronics NEC Electronics assumes no responsibility for any errors that may appear in this document e NEC Electronics does not assume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of NEC Electronics products listed in this document or any other liability arising from the use of such products No license express implied or otherwise is granted under any patents copyrights or other intellectual property rights of NEC Electronics or others e Descriptions of circuits software and other related information in this document are provided for illustrative purposes in semiconductor product oper
84. icrocontroller J UMPER Caution1 Insert neither capacitors nor resistors into the FLMDO FLMD1 line unless otherwise stated When pull down resistors are inserted into the FLMDO FLMD1 line the resistor value must be 470 Q or higher 2 The PG FP4 generally performs normally without pin processing 3 If the pins of the PG FP4 s output signals SO TxD are processed pull up or pull down with a resistor value in compliance with the specifications VIH VIL of the target device referring to CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS 4 Ifthe pins of the PG FP4 s input signals SI RxD RESET are processed pull up or pull down with a resistor value in compliance with the specifications loH loL of the target device referring to CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS User s Manual U15260EJ4VOUM 99 CHAPTER 8 NOTES ON TARGET SYSTEMS Figure 8 4 SIO Interface Circuit Example 4 RESET GNDJ3 Vpop SI Microcontroller J UMPER Caution1 Insert neither capacitors nor resistors into the FLMDO FLMD1 line unless otherwise stated When pull down resistors are inserted into the FLMDO FLMD1 line the resistor value must be 470 Q or higher 2 The PG FP4 generally performs normally without pin processing 3 Ifthe pins of the PG FP4 s output signals SO TxD SCK are processed pull up or pull down with a resistor value in compliance with the specifications VIH VIL of the target device referring to CHAPTER 9 TARG
85. ics products or if you have any other inquiries Note 1 Renesas Electronics as used in this document means Renesas Electronics Corporation and also includes its majority owned subsidiaries Note 2 Renesas Electronics product s means any product developed or manufactured by or for Renesas Electronics CENESAS User s Manual PG FP4 Flash Memory Programmer Document No U15260EJ4VOUMOO0 4th edition Date Published May 2004 NS CP K NEC Electronics Corporation 2001 Printed in Japan MEMO 2 Users Manual U15260EJ4VOUM PG FP4 complies with the EMC protection requirements WARNING This is a Class A EN 55022 1998 equipment This equipment can cause radio frequency noise when used in the residential area In such cases the user operator of the equipment may be required to take appropriate countermeasures under their own responsibility EEDT ST 001 11 CAUTION This equipment should be handled like a CMOS semiconductor device The user must take all precautions to avoid build up of static electricity while working with this equipment All test and measurement tool including the workbench must be grounded The user operator must be grounded using the wrist strap The connectors and or device pins should not be touched with bare hands EEDT ST 004 10 User s Manual U15260EJ4VOUM 3 EEPROM is a trademark of NEC Electronics Corporation PC AT is a trademark of International Business Mac
86. ified only when a single power supply flash memory microcontroller or a two power supply flash memory microcontroller that supports the Checksum command is used Users Manual U15260EJ4VOUM 63 64 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE lt 3 gt Security flag settings The lt Security flag settings gt dialog box is used to specify which security function is valid This function is valid only when a single power supply flash memory microcontroller is used Figure 4 31 Setup Window Security Flag Settings Security flag settings Disable Chip Erase Disable Block Erase Disable Program Disable Read Disable Boot block cluster reprogramming Reset vector HU h Disable Chip Erase check box If this check box is checked the Erase command becomes invalid in the entire flash memory area of the target device A warning message I907 Caution When Chip Erase is disabled chips can no longer be erased or programmed is displayed when is clicked in the Device Setup Window after checking this box Note Caution Be aware that if the security flag is set in the target device neither erasing nor writing to the device can be enabled afterward Note Since the Erase command is invalid the data that differs from the data already written in the flash memory cannot be written Disable Block Erase check box If this check box is checked the Erase command becomes invalid in all the blocks of the
87. in copying files Current Settings Destination Path C Program Files WECT ooles24PG FP4 Destination Folder NEC Tools Cancel Click the button to start the copy process User s Manual U15260EJ4VOUM 25 CHAPTER 3 SOFTWARE INSTALLATION You can follow the installation on the installation progress window You will be prompted to change the floppy disk if the GUI software is distributed on more than one floppy disk Figure 3 11 Installation Progress Window Copying program files C Program Filess WECT ools32 FR4 FP4 crit GEO You can always abort the installation with the button When installation is complete the following message window appears Figure 3 12 Setup Is Complete Window Setup setup is complete Back bance The program has been installed successfully and an entry has been made in the program menu to start the GUI software Select the view README TXT checkbox to start Notepad to show you the README TXT file Since this file is copied into your PG FP4 directory anyway you may review it anytime Click the button to exit installation The installation process is now complete and the setup utility has installed a new program folder which holds the GUI software and a PG FP4 unlnst icon which allows you to delete the GUI software and this software if they are not used anymore 26 User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALLATION Figure 3 13 Program Folder
88. invalid Download of SET file failed An error occurred while attempting to download a SET file The SET file may be invalid Checking device name failed The parameter file signature differs from the signature read from the device Checking device end address failed The parameter file signature differs from the signature read from the device User s Manual U15260EJ4VOUM 113 CHAPTER 10 ERROR MESSAGES 10 4 GUI Software Information Messages Informational messages do not need any workaround because they do not indicate an error condition The message is sent as information only and does not require any user action in response 1200 New firmware installed successfully in your Firmware upgrade completed with success programmer 1201 Opening parallel download port failed The Windows internal function to open the parallel port File download will be done on the serial port failed port occupied by other software 1202 Download via parallel port failed Communication via the parallel port failed Re download or use a serial port 1300 Value out of range The value entered in a dialog box is out of the allowable max min range The max min value or the most recent value will be written into the dialog element 1301 Multiple Program Areas are disabled The menu command Programmer Select Please enable Program Areas usage in the Device Programming area can only be used when it has been Setup Dialog enabled on the Advanced
89. ion Setup dialog box might fail due to one of these reasons Please verify proper selection of the port speed for the programmer E300 E301 E302 E303 Trying to connect Programmer failed E304 Trying to open serial port failed E305 Changing the communication speed of the programmer failed E306 Trying to connect Programmer failed E307 Trying to open USB failed E316 Trying to connect Programmer failed ver command failed Executing the ver command failed Port is already open Processing after setting the Programmer Communication E317 E400 Setup dialog box failed since the port is already open Check if programmer ports are set correctly E401 The communication port has not been opened so Sending a command to the PG FP4 is only possible after far the communication channel has been opened E500 Evaluating CRC answer failed The PG FP4 answered with an unexpected string after sending the Checksum command Operation failed Executing a command failed e g a verify error occurred for a signal from the target device Programmer is not responding Communication between the PC and the PG FP4 timed out Receiving failed Reading the PC port failed Appending information to communication logging Writing data to the communication log file failed file failed 12 User s Manual U15260EJ4VOUM E501 E502 E503 E600 oom CHAPTER 10 ERROR MESSAGES E750 Writing to INI File failed Writing to the
90. lays the valid memory area specified in the 2 MB user program area of the PG FP4 as either of the following on 0 User program Area 0 Ox00000000 to OxOOOFFFFF is specified on 1 User program Area 1 0x00100000 to 0x001FFFFF is specified off Entire 2 MB user program area is specified Display example Prog Area on 0 Displays the set status of Disable Chip Erase of Security flag settings as either of the following on The Erase command is invalidated on the entire flash memory area of the target device off The Erase command is executable Displays the set status of Disable Erase block of Security flag settings as either of the following on The Erase command is invalidated for a selected block in the flash memory of the target device off The Erase command is executable Displays the set status of Disable Program Block of Security settings as either of the following on The Program command is invalidated for a selected block in the flash memory of the target device off The Program command is executable When the Enter button is pressed next all the blocks prohibited from being programmed are listed Display example 00 01 02 04 05 Blocks O 1 2 4 and 5 are prohibited from being programmed When the Enter button is pressed next all the blocks prohibited from being erased are listed Display example 00 01 02 04 05 Blocks O0 1 2 4 and 5 are prohibited from being erased Note This
91. lt Usage when writing single power supply flash memory microcontroller gt lt 1 gt Connect the FA adapter and the type A target connector of the target cable 16 pins lt 2 gt Connect the type B target connector 10 pins and the I C adapter CN1 of the target cable User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALLATION 3 1 Graphical User Interface The graphical user interface GUI software allows easy and comfortable access to all features of the PG FP4 flash programmer 3 1 1 GUI software installation The installation program is located on the CD ROM delivered with the PG FP4 package To install the GUI software execute the following steps First insert the CD ROM into your CD ROM drive A setup screen opens as follows Figure 3 1 Initial Status of Setup Screen Install PG FP4 GUI Runs SETUP EXE from the SETUP directory Show the README file Opens Notepad to show the README file Japanese and English are selectable Refer to Figure 3 2 Show the User s Manual Opens Acrobat Reader to show the User s Manual Japanese and English are selectable Refer to Figure 3 2 Exit Exits from the initial screen User s Manual U15260EJ4VOUM 19 CHAPTER 3 SOFTWARE INSTALLATION Figure 3 2 lt Japanese English Selection gt Dialog Box English Japanese When Install PG FP4 GUI is clicked the setup program will be executed During initialization of the setup program a progress bar like that shown in Figure
92. m value 1913 Value is out of range The value of Frequency on the Standard tab of the Device Setup menu exceeds the maximum value 1914 Value is out of range The value of Frequency on the Standard tab of the Device Setup menu is smaller than the minimum value om 14 User s Manual U15260EJ4VOUM CHAPTER 10 ERROR MESSAGES 1915 The selection is out of range The value of Vdd V on the Advanced tab of the Device gt Setup menu is out of range 1916 The selection is out of range The value of Vdd2 V on the Advanced tab of the Device Setup menu is out of range 1917 The selection is out of range The end address of Range hex on the File Upload menu is smaller than the start address of that 1918 Input data is out of range The value of Multiply rate on the Standard tab of the Device Setup menu is out of range User s Manual U15260EJ4VOUM 115 APPENDIX A REVISION HISTORY The revision history is shown below Applicable Chapter refers to the chapter in each version 1 2 Third CHAPTER 2 HARDWARE INSTALLATION CHAPTER 2 HARDWARE Addition of operating software Windows 2000 and Windows XP INSTALLATION 2 1 System Requirements Change from PC 9821 series to PC 9800 series 2 3 2 PG FP4 control panel and connectors Change of status LED color from yellow to orange Addition of 2 3 9 C adapter CHAPTER 3 SOFTWARE INSTALLATION 3 1 1 GUI software in
93. n aiaa ai aa aaea aaa ai aAa EEE i 116 10 Users Manual U15260EJ4VOUM CHAPTER 1 OVERVIEW The PG FP4 is a tool that erases writes and verifies programs on an NEC Electronics on chip flash memory single chip microcontroller on the target board or FA adapter board This product can be used in graphical user interface GUI mode using a host computer or in standalone mode 1 1 Features The PG FP4 allows on board programming without removing the target device from the target system The user program is stored in the internal 2 MB flash memory of the PG FP4 and parameters for programming are stored in 8 KB EERPROM so that the target device can be rewritten in the standalone mode without having to connect the PG FP4 to a host e Serial interface connection RS 232C to host systems parallel interface for optional fast program download and a USB interface are available e CSI CSI H S UART I C and PORT interfaces are supported for data transfer to the target device e Programming voltage VPP can be selected from between 0 and 12 V e The PG FP4 can supply 0 to 6 V on the Voo line 200 mA max 1 2 PG FP4 Configuration in Graphical User Interface GUI Mode The configuration of the PG FP4 in GUI software mode is shown in the diagram below Figure 1 1 PG FP4 Configuration in GUI Software Mode ee Upload download a target program A PRM file into PG FP4 T i Store in El SET file j EEPROM
94. nd the update progress status will be displayed in the progress status display window Figure 4 18 Progress Status Display Window Updating internal amp external Firmware Completed 56 When the firmware update is complete the following message will be displayed Figure 4 19 Firmware Update Complete Message Firmware installed x i T200 Hew firmware installed successtully in your programmer User s Manual U15260EJ4VOUM 49 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 4 4 3 Device menu Clicking the Device menu displays the following pull down menu This pull down menu mainly consists of commands for programming the target device such as erase program and verify Figure 4 20 Device Menu File Programmer Blank check Erase J s Frogram Wer ify Read SECUFItY Checksum Autopracedure EPWI v Connect signature read Get Security Settings Setup 1 Blank Check menu d The Blank Check command initiates a blank check of the target device connected to the PG FP4 If 5 the flash memory of the target device is erased the blank check terminates successfully If the flash memory is not completely erased an error message is displayed Therefore the flash memory has to be erased first before programming can start Caution The Blank Check command is available only for single power supply flash memory microcontrollers 2 Erase menu e The Erase command initiates the eras
95. ng to CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS 4 If the pins of the PG FP4 s input signals SI RxD RESET are processed pull up or pull down with a resistor value in compliance with the specifications IOH loL of the target device referring to CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS User s Manual U15260EJ4VOUM 97 98 CHAPTER 8 NOTES ON TARGET SYSTEMS Figure 8 2 SIO Interface Circuit Example FAP 1008 2 Pe ee Vcc R Vcc 1 kQ Microcontroller J UMPER Caution1 Insert neither capacitors nor resistors into the Vpr line unless otherwise stated When pull down resistors are inserted into the Vpr line the resistor value must be 470 Q or higher 2 The PG FP4 generally performs normally without pin processing 3 If the pins of the PG FP4 s output signals SO TxD SCK are processed pull up or pull down with a resistor value in compliance with the specifications VIH VIL of the target device referring to CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS 4 If the pins of the PG FP4 s input signals SI RxD H S RESET are processed pull up or pull down with a resistor value in compliance with the specifications loH lOL of the target device referring to CHAPTER 9 TARGET SYSTEM INTERFACE CIRCUITS User s Manual U15260EJ4VOUM CHAPTER 8 NOTES ON TARGET SYSTEMS e Using single power supply flash memory microcontroller Figure 8 3 UART Interface Circuit Example 4 RESET GNDJ3 ee a som M
96. nt user programs and select either of them as the valid user program 12 User s Manual U15260EJ2VOUM CHAPTER 2 HARDWARE INSTALLATION 2 1 System Requirements Host PC Host machine Host interface File formats A PC supporting Windows 95 Windows 98 Windows NT 4 0 Windows Me Windows 2000 or Windows XP is required to run the PG FP4 in the graphical user interface GUI mode About 8 MB of free hard disk space is required to install the GUI software Any of the following can be used e PC 9800 series e PC 98NX series e IBM PC AT or compatible CPU Pentium 100 MHz or more RAM 32 MB or more Serial interface RS 232C capable of handling communication at 9 600 minimum baud up to 115 200 baud A parallel port may be used in addition to the serial interface to enable fast data download to the PG FP4 Alternatively a USB port Rev 1 1 is available Program files can be used in Motorola S file format or Intel HEX file format 2 2 Package Contents Please verify that you have received all the parts listed in the package contents list included with the PG FP4 package If any part is missing or seems to be damaged please contact an NEC Electronics sales representative or distributor User s Manual U15260EJ4VOUM 13 CHAPTER 2 HARDWARE INSTALLATION 2 3 System Configuration and Components The PG FP4 system configuration is as given in the diagram below Figure 2 1 PG FP4 System Configuration Host machine
97. nts Note Footnote for item marked with Note in the text Caution Information requiring particular attention Remark Supplementary information Numeral representation Binary xxxx or xxxxB Decimal xxxx Hexadecimal OxxxxH or xxxxH Any character or item on screen OK Name of button User s Manual U15260EJ4VOUM T7 Menu lt gt Dialog box name Terminology The meanings of the terms used in this manual are as follows Target system User designed board on which NEC Electronics on chip flash memory microcontroller is mounted FA adapter Adapter board to write programs to NEC Electronics on chip flash memory microcontroller Note The FA adapter board is a product of Naito Densei Machida Mfg Co Ltd If you have any questions about the FA adapter board contact Naito Densei Machida Mfg Co Ltd Tel 81 45 475 4191 Users Manual U15260EJ4VOUM CONTENTS CHAPTER T OVERVIEW aniria a i iaeh a ec ote E E tuauvenduceds 11 Wed FEeatUreS naano ae e a araa aA oE OEE Aaa A OAOE ENa 11 1 2 PG FP4 Configuration in Graphical User Interface GUI Mode cssseeeeeeseeeeeeneeees 11 CHAPTER 2 HARDWARE INSTALLATION cccccesccceseecenseecenseecensescenseseaseeceasescoaseseeasesenseesenseess 13 Zr System REGUIFCINGIS airia aa aAA a AAA 13 2 2 Package Contents sinccr dsini aaas aaa aa a aa aE EE 13 2 3 System Configuration and COMpOonentS ccccccccessseeeeeeeeeseeeeeeeesseeeeeoeess
98. o the PG FP4 is read The device name is displayed on the message display Display example Signature D7OF3025A When the Enter button is pressed next the valid memory area Area 0 or Area 1 is changed if the 2 MB user program area is used as two independent 1 MB memory areas Area 0 and Area 1 e Display example when Enter button is pressed Commands Prog Area now 0 The valid memory area is changed from Area 1 to Area 0 If the 2 MB area is used as one user program area the valid memory area cannot be changed by using this menu e Display example when Enter button is pressed Commands Prog Area dis The valid memory area cannot be changed Check the memory area currently selected by using Prog Area of Option Setting Notes 1 Download the user program in advance in the GUI software mode 2 This command is valid only with a single power supply flash memory microcontroller If any other microcontroller is used this command is not displayed 3 This is valid for the programming area Chip Block and Area currently set for the PG FP4 User s Manual U15260EJ4VOUM 81 CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE 6 1 2 Type Setting menu The Type Setting menu is used to check the target device rewrite environment currently set for the PG FP4 All the values displayed were set during the last programming session The setting cannot be changed by this menu Type Setting gt e Pressing the Next key dis
99. ode Chip C tart fo Selective Programming verit Read HOCK Stark foonong C w e oa Show Address End O3FFFF When Chip is selected The entire flash memory area of the target device is subject to rewrite processing When Block is selected Specify the Block number range subject to rewrite processing by using Start End The Start End list boxes display the Block number where the flash memory of the target device is configured Block cannot be selected with a two power supply flash memory microcontroller When Area is selected Specify the Area number range subject to rewrite processing by using Start End The Start End list boxes display the Area number where the flash memory of the target device is configured Area cannot be selected with a single power supply flash memory microcontroller Show Address check box Specifies whether numbers or addresses are displayed in the Start End list boxes If this check box is checked addresses are displayed If it is not checked numbers are displayed Selective programming This cannot be used Users Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE c Advanced setup Advanced setup is used to specify the programming voltage for programming the target device command options and security flag setting When Advanced is clicked the following window is displayed Figure 4 28 Device Setup Window Advanced Properties Standard Advanced
100. oot area setting of the target device connected to the PG FP4 and reflect the result in the Advanced Setup menu When this menu is specifiable be sure to confirm the security status and the boot area by executing the Get Security Settings menu before executing a security command and then add the security specification Users Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Figure 4 21 Get Security Settings Menu Properties Standard Advanced Supply voltage Command options Vdd 05 00 Ww Blank check before Erase Vdd i 00 00 er Read verify after Program Security flag after Program m On Target Checksum after Program pp P 00 00 Securty flag settings Clk Vdd i Disable Chip Erase Disable Block Erase Disable Program Reset Vdd i Disable Read Serial Port dd Disable Boot black cluster reprogramming Reset vector h Program downloadupload Boot block cluster setting End Boot block 16 Show Address omea e H S Input dd W Enable two Program Areas 11 Setup menu The Setup menu is used to perform flash memory writing settings in accordance with the user JO environment and command option settings Each time the GUI software is started the parameter file PRM and customized setup file SET that were used last are read and their setting contents are displayed On the Setup menu settings can be changed in accordance with the user environmen
101. p files set Cancel Parameter file FOF 30254 PRM lt 4 gt Select 70F3025A PRM from the Parameter file pull down list Figure 5 8 Selecting Parameter File Parameter file FOF 30254 PRM FOF S025 PAM FOR S08Sy PAM forFUU s PRM lt 5 gt Enter the name of the newly created customized setup file and click the button Figure 5 9 Saving Customized Setup File File name FOF 30254 se save az type FP4 setup files set Cancel 72 User s Manual U15260EJ4VOUM CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE lt 6 gt Set the other items in accordance with your programming environment Especially set Communication interface to device and Supply oscillator in accordance with the specifications of the device selected Specify a flash memory range to be manipulated as Operation Mode the flash memory range that can be set is defined by the parameter file in accordance with the specifications of the device In this example it is assumed that the following settings are made lt Communication interface to device gt Port SIO H S Speed 625 kHz lt Supply oscillator gt On Target Not checked The clock of the PG FP4 is supplied to the target Frequency 6 MHz Multiply rate 5 lt Operation Mode gt Chip User s Manual U15260EJ4VOUM 73 CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE lt 7 gt Next display the Advanced dialog box Figure 5 10 lt Advanced
102. plays the Option Setting menu e Pressing the Enter key displays the following commands that can be executed from the Type Setting menu e Pressing the Cancel key displays the Commands menu again Device Port J Next button Multiply Rate J Next button Serial CLK J Next button CLK source J Next button PG CPU CLK J Next button Target CPU CLK J Next button Mode J Next button PRG Areal 82 Device Port displays any of the following to indicate what is selected as an interface between the target device and the PG FP4 SIO 0 SIO1 SIO 2 SIO W S IIC O IIC 1 IIC 2 IIC 3 UART 0 UART 1 UART 2 UART 3 PORT 0 PORT 1 PORT 2 Multiply Rate displays the multiplication rate of the operating clock of the target device Serial CLK displays the serial clock rate in Hz that is used to interface the target device and PG FP4 CLK source indicates either of the following as a source to supply the operation clock to the target device Programmer Clock is supplied from the PG FP4 Target Clock is supplied on the user system PG CPU CLK indicates the frequency of the clock supplied by the PG FP4 in MHz Target CPU CLK indicates the frequency of the clock on the user system that is supplied to the target device in MHz Mode indicates any of the following operation modes when the Blank Check Erase Program Verify or EPV command is executed chip area block Display example Mode BEPV chip
103. quipment communications equipment test and measurement equipment audio and visual equipment home electronic appliances machine tools personal electronic equipment and industrial robots High Quality Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems anti crime systems safety equipment and medical equipment not specifically designed for life support Specific Aircraft aerospace equipment submersible repeaters nuclear reactor control systems medical equipment or systems for life support e g artificial life support devices or systems surgical implantations or healthcare intervention e g excision etc and any other applications or purposes that pose a direct threat to human life You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics especially with respect to the maximum rating operating supply voltage range movement power voltage range heat radiation characteristics installation and other product characteristics Renesas Electronics shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products beyond such specified ranges Although Renesas Electronics endeavors to improve the quality and reliability of its products semiconductor products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under ce
104. re this FP4 GUI will HOT run properly Inatall new firmware In your programmer In both cases update the software to the latest version Check the NEC Electronics Website at http www necel com micro ods eng index htmi and download the necessary software update packages 34 User s Manual U15260EJ4VOUM CHAPTER 3 SOFTWARE INSTALLATION 3 2 1 Firmware update installation The new firmware can be installed using the GUI software Before this process starts download the new firmware onto the hard disk of the PC from the NEC Electronics Website A typical name of the firmware program file is FP4_VUP_xxxx REC where xxxx is the version number of this firmware 1 Firmware update from warning message The firmware update procedure starts when you click the button in the firmware update error message refer to Figure 3 25 From the lt File open gt dialog box that appears select the firmware update program file FP4_VUP_xxxx REC Several commands will be sent to the PG FP4 and a progress indicator will inform you of the download progress As soon as the firmware update is complete a message will appear Figure 3 26 Firmware Update Complete Message Firmware inztalled kE x oe iD 1 200 New firmware installed successtully in your programmer 2 Firmware update from menu bar The lt Update Firmware gt dialog box shown in Figure 3 25 is opened by selecting Update Firmware from Programmer on the menu bar Hereafter
105. rea becomes valid after the Security command is executed The function differs depending on the target device Only usable functions can be set Figure 4 33 Setup Window Security Flag Settings M Boot block cluster setting End Boot black i Show Address The blocks up to the end boot block can be used as the boot area When the Disable Boot block cluster reprogramming check box under the Security flag settings menu is valid the specified boot area becomes valid after the Security command is executed Caution Be aware that if the security flag is set in the target device writing to the boot area in the device cannot subsequently be enabled Users Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE 4 4 4 Help menu Clicking the menu displays the following pull down menu Figure 4 34 Help Menu Fel FP4 File Frogrammer Device Bates Contents F 1 Contents menu The Contents menu starts the Windows Help engine and opens the contents dialog box of the PG FP4 help file 2 About menu The About menu opens the following program entry window The version displayed below the PG FP4 indicates the version of the GUI software By clicking this window the display can be exited Figure 4 35 About Window AEA Urn bel 1 E PRESS REE RE REESE RS REFERS Cie wil SS a Pra L Users Manual U15260EJ4VOUM 67 CHAPTER 5 SAMPLE PROGRAMMING SESSION USING
106. rtain use conditions Further Renesas Electronics products are not subject to radiation resistance design Please be sure to implement safety measures to guard them against the possibility of physical injury and injury or damage caused by fire in the event of the failure of a Renesas Electronics product such as safety design for hardware and software including but not limited to redundancy fire control and malfunction prevention appropriate treatment for aging degradation or any other appropriate measures Because the evaluation of microcomputer software alone is very difficult please evaluate the safety of the final products or system manufactured by you Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances including without limitation the EU RoHS Directive Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations This document may not be reproduced or duplicated in any form in whole or in part without prior written consent of Renesas Electronics Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas Electron
107. same it sequentially executes the Erase and Program commands explained above When the Program command is executed whether the write level is secured is verified after the program has been written Note however that this verification does not detect a communication error of the user program that is transmitted from the PG FP4 to the target device To transmit the memory contents of the PG FP4 to the target device to compare them with the data written to the flash memory of the target device because a communication error of the user program was detected specify automatic execution of the Verify command after execution of the Program command by using the Command options on the Advanced tab of the Device gt Setup menu During EVP the progress is displayed in the communication log window indicating the operation of the programmer For the selected command and its execution operation and message refer to CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE You may abort the EPV procedure by pressing the Cancel button on the PG FP4 After completing the EPV command the GUI software displays the target device command execution result Signature read menu The Signature Read command is used to read the signature information of the target device such as the device name and flash memory information 10 Get Security Settings menu The Get Security Settings menu is used to read information on the security flag or b
108. stallation Change of Figure 3 6 Software License Agreement Window Change of Figure 3 12 Setup Is Complete Window Change of name of file to be installed Addition of 3 1 2 USB driver installation 3 1 3 GUI software uninstallation Addition of 2 Uninstallation using Add Remove Programs 3 2 Firmware and GUI Software Update Installation Addition of procedures to update firmware CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE Change of Figure 4 3 GUI Software Main Window Addition of Programmer Select Programming area button to Table 4 1 Toolbar Buttons 4 4 2 3 Select Programming area menu Addition of an icon to Select Programming area menu 5 Update Firmware menu Addition of Update Firmware menu Change of Figure 4 19 Device menu 4 4 3 2 to 7 and 9 b to c Addition and change of description Change of Figure 4 32 About Window CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE CHAPTER 6 PG FP4 OPERATION IN STANDALONE MODE CHAPTER 6 PG FP4 Change of status LED color from yellow to orange OPERATION IN 6 1 1 Commands menu STANDALONE MODE Addition to Note and addition of Note 3 6 1 5 Utilitiy Misc menu Addition of HEX File Name CHAPTER 5 4 to 8 Addition and change of description CHAPTER 7 CONNECTORS AND CABLES CHAPTER 7 CONNECTORS AND CABLES Addition of description about power supply connector HD Sub 9 serial host connector HD Sub 15 target
109. started correctly the following screen appears Figure 4 3 GUI Software Main Window FP4 File Programmer Device Help Device Mame fORSS3 Status auboconnected Parameter file Parallel port in remote control mode Name 70F2237 PRM eprogarea Version E1 00a Active Program Area 1 Device Setting fi eae evice Setting file EE E un Name 7ORS237 SET D ate Tue Feb 1 11 47 24 Download file Name kd intel exp hex Date Sun Dec OF 23 02 34 Chksunm 49646895 Prog Area Connection to device Port UART cho Pulse Num Speed 153600 Wide 05 00 Supply Freg FOOOO00 Multiple 4 00 Block Area File Checksum Type CAC sum 32 bit Address OOO0Q000 OOOFFFFF Value DODATDBASI Time 0 sec This window consists of the following items Menu bar displayed on top Displays executable menus of the PG FP4 Toolbar displayed below the menu Displays frequently used commands as icons Communication log window displayed below the toolbar Displays all commands transmitted to the PG FP4 and messages returned from the PG FP4 Programmer parameter window displayed on the right side of the communication log window Displays programming parameter settings Caution The Programmer Parameter window shows the parameter information previously set from the PC This information may differ from the settings of the programmer currently connected 38 User s Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING G
110. t except for the parameters that are dimmed In addition new settings can be saved to the customized setup file the data of the parameter file cannot be changed a Parameter file and customized setup file The parameter file and customized setup file have the setting information necessary for rewriting the flash memory of the target device e Parameter file This file stores the timing and parameter data necessary for rewriting the flash memory of the target device Do not change the data of the parameter file as it guarantees the rewrite data The parameter file is protected by a checksum If the checksum is illegal the PG FP4 does not accept the parameter file e Customized setup file Save the values of settings that have been made in accordance with the user environment to the customized setup file after downloading the parameter file The customized setup file saves the settings of the Setup menu including the corresponding parameter file name so that a new environment can be set by downloading the customized setup file when the environment is started next time User s Manual U15260EJ4VOUM 53 54 CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE b Standard setup This menu is used to set the rewriting environment of the target device s flash memory The mode of communication with the target device and the operating clock of the device differ depending on the device used For details refer to the manual of the device used
111. t be equipped with a device interface that complies with the target cable specifications For details refer to CHAPTER 7 CONNECTORS AND CABLES 2 3 4 Power supply The power supply FW7207 15 is equipped with a 2 1 x 55 x 14 DC plug and may be connected to the mains using one of the AC plugs available in Europe the UK the USA and Japan For the power supply specifications refer to CHAPTER 7 CONNECTORS AND CABLES Caution Do not use any other AC adapter Connect only the provided AC adapter to the power supply jack 2 3 5 RS 232C host connection The RS 232C host interface enables communication to the PG FP4 Windows 95 Windows 98 Windows NT 4 0 Windows Me Windows 2000 or Windows XP may be used to operate the PG FP4 which is connected to the serial port The RS 232C data transfer conditions are 9 600 baud 8 data bits 1 stop bit no parity and selectable hardware handshake The baud rate may be selected from 9 600 bps default 19 200 bps 38 400 bps 57 600 bps or 115 200 bps For detailed specifications of the host interface refer to CHAPTER 7 CONNECTORS AND CABLES 2 3 6 Parallel host connector The parallel host connector may be configured as follows Centronics interface configuration Program data can be downloaded to the PG FP4 via a high speed parallel port from the host system For detailed specifications of the parallel interface refer to CHAPTER 7 CONNECTORS AND CABLES 16 User s Manual U15260EJ4VOUM CHAPTER 2 HAR
112. t order on the uPD70F3025A if necessary insert the device to be newly written in the FA adapter and execute step 7 In this example since Read verify after Program is checked whether the data communication between the PG FP4 and target device has been correctly performed after executing the EPV command is checked Note When the Program command is executed whether the write level is secured is verified after the user program has been written Note however that this verification does not detect a communication error of the user program that is transmitted from the PG FP4 to the target device For details of this command refer to 4 4 3 Device menu User s Manual U15260EJ4VOUM Uf 78 CHAPTER 5 SAMPLE PROGRAMMING SESSION USING GUI SOFTWARE Terminating system lt 1 gt If it is not necessary to program other devices select File Quit and terminate the GUI software All the settings made so far have been saved so that they can be reused when the GUI software is restarted all the settings are also saved to the internal EEPROM of the PG FP4 lt 2 gt Remove the FA adaptor target system from the target cable lt 3 gt Turn off the switch of the power supply unit lt 4 gt Remove the power supply unit and either the RS 232C cable or USB cable from PG FP4 Caution If the E501 Operation failed error occurs check the following points Check the wiring of the pins used for writing the target device on the target board
113. top debugging first F751 Opening debug file failed F752 Debug information overflow Discharging actual message F753 Setting up message box failed F800 Memory cannot be allocated F801 Shortage of memory F802 Temporary file could not be read abort Save File F803 File save error abort Save File F804 error line lt line number gt Data error abort DATA Check F805 error line lt line number gt Data Count error abort Data Count Check F806 error line lt line number gt Check sum error abort Check sum Check F807 cannot open Temporary File abort Save File F808 HEX format error F809 Too large address F810 Parameter of Start Address is invalid F811 Parameter of End Address is invalid F812 File load error abort F813 Temporary file could not be created abort F902 Unable to find any PRM file Please install PRM The GUI software could not find any PRM file in sub files directory PRM Download the PRM file for the target device to the sub directory PRM oom 10 User s Manual U15260EJ4VOUM CHAPTER 10 ERROR MESSAGES 10 3 GUI Software Error Messages In addition to the error messages listed below error messages can be displayed directly from the PG FP4 E200 Opening script file failed Opening the specified script file failed Script file in use E201 Updating the firmware will take several minutes Check if the Update Firmware menu has been started
114. zed setup file A window to create a new customized setup file appears Figure 4 24 Create New Customized Setup File Window Save in a Set t CF m a 70F30254 5et File name FOF 30254 se save as lupe FP4 setup files set Cancel Parameter file FOF 30254 PRM Parameter files saved to lt PG FP4 install path gt PRM are shown in the parameter file list box Select a parameter file for the target device After selecting the parameter file enter the name of the customized setup file that is newly created and then click the button Users Manual U15260EJ4VOUM CHAPTER 4 PG FP4 OPERATION USING GUI SOFTWARE lt 2 gt Communication interface to device Communication interface to device selects the channel for communication between the PG FP4 and target device For the communication port and communication rate that can be selected refer to the user s manual of the device used Figure 4 25 Setup Window Communication Interface to Device Communication interlace to device Fort S10 cho Pulse number 0 Speed 625kHz b E Address foo Port list box Select the mode of communication between the PG FP4 and target device from the following The communication mode is determined by the number of Ver or FLMDO pulses output by the PG FP4 The selectable communication mode differs depending on the target device Refer to the user s manual of the target device used and sele
Download Pdf Manuals
Related Search
Related Contents
MODEL 4192A LF IMPEDANCE ANALYZER Memorex MP3112 Portable CD Player User Manual 使用方法 1. 使用するマスク治具の大きさに合せて、専用の剥離装置 Manual MC5 Programming Software HP LaserJet 5200/5200L Series printers Service Manual Lightolier TU HO Series User's Manual BETRIEBSANLEITUNG Glättmaschinen Typ LTM 600 - 900 SERVICE MANUAL - MiniDisc Community Page Copyright © All rights reserved.