1. Be sure there is no static electricity on the scale use an anti static spray to remove static electricity FEATURES Auto shut off adjustable e Auto calibration Auto zero tracking e AC Power optional Removable display w 3ft cord e kg Ib Ib 0z g conversion Large LCD 6digits 15 mm high e hold function Large square weighing tray with multiple attachments PARTS DESCRIPTION Right SIDE AC adaptor Socket ON OFF key Turns the scale power on off HOLD KEY Holds the display for 120 seconds ZERO key for TARE Sets display to zero or Subtracts weight of a container UNIT key Changes weighing units eg kg or Ib Batteries Use R14C 4 pieces dry batteries HOLD FUNCTION Once the hold key is pressed the weight will remain on the display for 120 seconds after the item has been removed from the scale so the weight can easily be read 1 Place the item on the scale s platform 2 Wait for the stable weight to be displayed 3 Press the hold key The hold indicator will turn on 4 Remove the item from the scale platform The item s weight reading will remain on the display for 120 seconds 5 Quit the hold function Once an item is weighed and the hold function is enabled you may want to end the hold function Press the hold key again to cancel the hold indicator and return the scale to normal weighing mode AUTO OFF FUNCTION SETTINGS To enable or disable the auto off fea
2. locked on 8888 this often indicates low power However sometimes it also may indicate a serious zero mark error This means when you turn the scale on it can t determine what zero is a slight zero mark error will cause situation 1 above Thus if new batteries do not fix this error please follow the warranty instructions 4 If the display shows UNST this means the scale is not stable Try operating the scale on a more stable surface amp be sure nothing is on the tray or stuck under the tray when you turn it on If the problem persists it may be an indication of fatal sensor damage 5 If the scale is on AC power and it will not properly stabilize fluctuating weights are shown on the display this may be caused by a malfunctioning AC adaptor Please try operating the scale on Battery power to see if the problem persists If the problem does not occur on Battery power then it is a sign of a bad or improper AC adaptor Please replace the AC adaptor If the problem occurs on Battery power also it may be a sign of environmental issues please the special warning in this manual Although the ULTRASHIP is designed to be extremely durable It s important that you never overload or drop shock the scale If you ship the scale be certain to pack it extremely well to prevent shipping damage Scales are delicate instruments and unlike Cellular phones scales have delicate sensors that determine how much an item weighs If you drop or shock your scale t
3. This document hosted by OldWillKnottScales seared SS es 1 el HERE Am to visit us the next time you need a scale My Weigh Ultraship Series User Manual Low Batteries bad battery connections amp Faulty AC Adaptors are the 1 cause of Ultraship malfunction and inaccuracy We test all of our scale returns from consumers Fully 60 of consumer returns are battery related problems This sounds silly but it s true A scale will perform slowly or read inaccurately when it has low batteries Please replace the batteries often and only use good quality batteries We include good quality batteries with all of our scales but batteries can run low in storage If your scale simply won t turn on while on Battery power this is often caused by loose battery connections Battery prongs terminals are made of metal They must be making good contact with your batteries in order for the scale to power on You can use a paperclip to slightly bend the battery prongs to make them have a better connection Also some poorly designed batteries have recessed or partially obstructed battery terminals This may cause your prongs to be touching the plastic housing of the battery instead of the metal battery terminal A Faulty AC adaptor can cause your scale to act unstable with numbers jumping all around Please test your scale with a good set of batteries instead of the AC adaptor to determine if perhaps the AC adaptor is faulty Some Ultra 75 scales will need a diff
4. bration is almost never required If the scale is inaccurate calibration may be desired when the scale is first set up for use or if the scale is moved to a different altitude or gravitation This is necessary because the weight of a mass in one location is not necessarily the same in another location Also with time and use mechanical deviations can occur How to calibrate The UL 30 35 requires a 10kg calibration weight to calibrate The UL 50 55 and UL 75 require a 20kg calibration weight you can use a combination of weights such as 5 2kg weights 1 The scale must be powered OFF Press and hold ZERO first then Press ON OFF while keeping the ZERO button depressed then release both keys The display will show the A D value a series of random numbers 2 Wait for the stable A D value to be displayed Press UNIT the display will show OSAVE then the display will return to the random A D value 3 Place the 10kg UL 30 or 20kg UL 50 amp UL 75 weight s on platform Wait for the stable A D value to display then press UNIT the display will show OSAVE Calibration is complete remove the weight s 4 Turn the scale OFF Press the ON OFF key then turn it back ON and check some weight readings If calibration is still incorrect repeat calibration but try it more slowly If calibration is repeatedly incorrect then 1 Replace the batteries 2 Try a more stable surface or vibration and interference free location 3
5. damage to this scale Avoid overloading the scale as this may cause permanent damage and void your warranty do not EVER exceed the maximum capacity of the scale Keep the scale away from water this scale is not water resistant Shock injury and electrical damage can occur if used in a wet location Matter charged with static electricity could affect accuracy Discharge all static electricity For example one method is to use Static Guard spray and spray it on both sides of the weighing platform SPECIFICATIONS Model UL 35 Capacity 35lb 16kg Division 29 0 10z Division 5g 0 20z Model UL 55 Capacity 55lb 25kg Division 2g 0 10z Division 10g 0 50z Model UL 75 Capacity 75 9 b 34kg Division 5g 0 10z Division 10g 0 50z Platter Tray 160x203mm Net gross weight 750 950g Package Standard carton 28x26x10 5 cms3 Operating Temperature Optimum 15 30c 62 90f Power source 4xR14C Size Batteries or AC DC Adapter 9V 100mA optional or 10V SPECIAL WARNING Cell Phones Cordless Phones and any radio frequency device can cause temporary interference and cause the scale to temporarily not work properly Please do not use any electronic device near the scale Just like in an Airplane do not use your cell phone near the scale when it is in use While there is NO risk of permanent damage to the scale interference can cause an incorrect calibration or incorrect weight readings CALIBRATION When to calibrate cali
6. e a container for weighing Place an empty container on the platform Wait for the stability indicator to be displayed and press TARE Place the objects to be weighed in the container The weights will be displayed on the LCD
7. erent or improved AC adaptor then the Ultra 50 and Ultra 30 You will know if you have this problem because the scale will power on but the numbers will fluctuate bounce all around Most Ultraship 75 s do not have this problem it s only happened a few times and it was caused by a slightly underpowered AC Adaptor the output was slightly less then normal The Ultra 75 requires just a bit more power then the Ultra 30 35 50 or 55 and thus is the only model affected by an AC adaptor that is giving a slightly less then normal output IMPORTANT MANUAL CORRECTION 2005 2006 Model Notes During production we sometimes modify the Ultraship slightly to make it easier to use and perform more stable This can cause some typos in the manual Note that on the newest Ultraships there is NO STABLE INDICATOR we removed it on some models as it was causing a software conflict The BEEP function was also removed due to customer complaints TROUBLESHOOTING amp OPERATION NOTES 1 If the scale does not perform accurately please recalibrate as outlined in the manual 2 If the Display ever becomes locked on EEEEE this indicates that the scale was shocked dropped or otherwise damaged and the delicate weighing sensors have been damaged You can try recalibrating the scale If the sensor has not been hurt too badly it may work again after recalibration Otherwise you will have to follow the warranty instructions that came with your scale 3 If the display becomes
8. hese sensors feel the shock and are sometimes destroyed This happens with all digital scales We design our scales to be as resistant to shock or drops as possible however there is no way for us to protect 100 against load cell or sensor damage A well treated scale will provide years of reliable and accurate weighing However an abused scale will only work until its sensors are damaged damaged Click here for a printable PDF Version of the Ultra 30 35 50 55 Manual Click here for a printable PDF Version of the Ultra 75 Manual SAFETY PRECAUTIONS All safety messages are identified by the words WARNING and CAUTION These words mean the following IWARNING Important information to alert you to a situation that might cause serious injury and damage to your property if instructions are not followed ICAUTION Important information that tells how to prevent damage to the equipment When using the scale the following safety precautions should always be followed WARNING Use only the correct AC adaptor with the scale Other adaptors may cause permanent electrical damage CAUTION Avoid placing the scale in direct sunlight this may cause discoloration or malfunction Replace all batteries at the same time Do not replace only a portion of the 4 batteries as this may cause a malfunction If the scale is not to be used for a long period of time remove all batteries from the battery compartment to avoid leakage which may cause
9. ture follow these directions 1 Start with the power off the power must be OFF Press and hold the Hold key first then press ON OFF then release both keys The display will show A_ON or A_OFF 2 Selection of auto shut off mode Press the Hold key the display will show A_ON or A_LOFF A_ON means the auto shut off function is active Press Hold again the display will show A_OFF this means the auto shut off function is inactive 3 Return to weighing mode Press ON OFF to turn the power off press ON OFF again to turn on the power and the scale will return to weighing mode WEIGHING WEIGHING Before weighing Whenever possible please allow the scale to warm up for several seconds after first turning the power on so that the scale will function properly and accurately Error messages EEEE Overload Low battery Weighing procedures 1 Press ON OFF to turn on the scale When the power is turned on all display segments appear for a few seconds and 0 will appear on the display 2 Select the weighing unit with UNIT Press UNIT to select a weighing unit kg Ib lb oz or g Once the unit has been selected the selected unit will be displayed next to the weight value 3 Start weighing If you do not use a container for weighing Verify the reading is 0 If not press TARE to display 0 Place the items to be weighed on the platform The weight will be displayed on the LCD If you us

Download Pdf Manuals

image

Related Search

Related Contents

Rack2-Filer Smart - PFU  JBL CINEMATM BASE - Luxusní  DEVO F12E Mode d`emploi  Brochure sur le LIFEPAK CR Plus ( PDF )  Aquatic AI6060RC29 User's Manual  FICHE DE DONNEES D`ENTRETIEN  LaCie Little Big Disk 240 GB SSD  Registrador de Dados com Termopar de 12  GR-D750U  Certificado de Garantia - CRAM Grupos Electrógenos  