1. GT2000 OWNER S MANUAL WELCOME Ae 2 1 1 NEJEN a nu 3 RECORDS SPECIFICATION 5 4 5 oaa a n a SERNIN 5 PRODUCT INTRODUCTION asassasa afia s sa 6 7 DIAGRAM 5 spies nn 8 11 SETUP amp OPERAT 12 14 DISASSEMBLY ASSEMBLY ce UNE 15 16 4 PU WUWU NUWUN ED Pp oo B ae Pere ee s Bb a 60 2 NS 1 7 4554 22 222222 12 18 WWW GREENTECHENV COM Welcome to the joys of cleaner air and a healthier life You are the owner of one of the most technologically advanced purification systems available the GT3000 The combination of four innovative technologies Photo Catalytic Oxidation PCO Needlepoint Ionization Scalable Purification and Electrostatic Filtration sets the GT3000 apart from similar air purifiers on the market The GT3000 uses these technologies to reduce particles
2. and dangerous pathogens in your home or office Enhancing your overall quality of life has never been this easy AVAILABILITY OF SUPPORT This Owner s Manual will provide comprehensive information regarding all aspects of your GT3000 If you experience any technical issues with your device refer to the Troubleshooting section of this booklet The solution for many of the commonly reported problems is listed in detail in the Troubleshooting section page 18 If the problem you are experiencing is not listed in the Owner s Manual and or you need additional support please feel free to email us at support GreenTechEnv com Copyright 2011 GreenTech Environmental All Rights Reserved 6 FOUR TECHNOLOGIES Advanced Photo Catalytic Oxidation The Photo Catalytic Oxidation PCO Technology in the GT3000 not only destroys biological contaminates but also produces purifying plasma which eliminates odors mold bacteria and viruses PCO Cells have been proven to reduce dangerous pathogens by more than 99 in less than 24 hours through a process called molecular disassociation which actually breaks down the molecules instead of simply covering up the source The result at the end of the breakdown process harmless carbon dioxide and water vapor Needlepoint Ionization The GT3000 generates a continuous stream of millions of negative ions that circulate throughout the home These ions charge particles such as dust dander or bacteria causing the
3. Slot ensuring that the Purification Plate is sliding into the grooves on either side NOTE About halfway in the Purification Plate Connectors ate parted Continue sliding the Purification Plate into the Purification Plate Slot until there is approximately one inch of the Purification Plate remaining outside of the Purification Plate Slot and significant resistance is met Be careful not to force the Purification Plate further into the Purification Plate Slot as this could seriously damage your unit Copyright 2011 GreenTech Environmental All Rights Reserved 16 Installing the FILTER ASSEMBLY 1 Hold the Fier Assembly with the larger flat side where the honeycomb layer of the filter is visible facing the interior of the unit A sticker reading Caution Reinstall Filter After Cleaning is located on the opposite side of the Assembly This sticker should be visible when you install the Filer Assembly 2 Insert the bottom of the Fier Assembly into the tabs on the rear of the unit and then seat the Filter Assembly on the rear of the unit NOTE If the user fails to insert the Fi ter Assembly into the tabs appropriately disassembling the unit in the future could be extremely difficult 3 Screw the two Brass Thumbscrews into their holes at the top corners of the Filter Assembly Installing the Rear Cover 1 Place the tab at the top of the Rear Cover into the hole at the top of the Fiter Assembly then lay the Rear Cov
4. and inactivate microbes in the output radius creating a healthier living space with pristine air quality The GT3000 is designed to provide years of trouble free service when it is properly maintained Keep this manual It will guide you through the steps to operate your machine and the maintenance procedures which will keep your GT3000 in tip top shape for years to come Even when properly cared for some parts of the unit will need to be replaced periodically Replacement parts can be purchased from your authorized distributor or directly from GreenTech Environmental www GreenTechEnv com We hope you enjoy your GT3000 and the overall healthier living environment it creates Sincerely Hard Allen Johnston President CEO GreenTech Environmental Copyright 2011 GreenTech Environmental All Rights Reserved LIMITED WARRANTY Your GT3000 Air Purifier is warranted to be free from all defects in material and workmanship in normal household use for a period of 1 year from date of purchase The warranty is granted only to the original purchaser and members of his or her immediate household The warranty is subject to the following provisions This warranty does not cover parts of the Air Purifier that require replacement under normal use This includes the purifier plate and rear filter assembly Although the PCO cell requires periodic replacement the cell is warranted for the same 1 year period as the purifier Any damages or malfunc
5. DIGATOR 6 PURIFICATION LEVEL INDICATOR Mode Specific Display PURIFIER SETTING 8 00 Q FT MUST NOT EXCEED 1 f SIZE OF AREA NORMAL HIGH AWAY REPLACE PLATE REPLACE PCO CELL PERFORM CLEANING 2 MAINTENANCE REMINDERS PURIFICATION LEVEL WARNING AWAY MODE WARNING 11 HIGH NORMAL MODE AWAY MODE MODE PURIFIER SETTING Ci 71 Ci FT Di Os gi ag SIZE OF AREA LI LI LI TTT TTT TT HIGH ac all AREA MUST TTT TTT LIT 7 7 UNOCCUPIED AWAY MODE SPECIFIC DISPLAY NORMAL TECHNOLOGY INDICATOR PCO HIGH SQUARE FOOTAGE INDICATOR AWAY MODE DURATION INDICATOR HOURS MINUTES SETUP amp OPERATION INITIAL SETUP Ideal Placement There are several important factors to consider when selecting a location for your GT3000 Make sure the location you choose is as far away from the HVAC air return duct as possible This will ensure that the purification produced by the GT3000 is optimally circulated Place the unit on top of something tall such as a bookcase a shelf or a mounting bracket leaving only 12 to 24 inches between the unit and the ceiling To ensure the unit works properly there should be as much space as possible in front of your GT3000 so that it can efficiently process the air in the area Never place an operating unit on the floor Initial Settings Be
6. GreenTech Environmental www GreenTechEnv com The PCO Cell is Not Lighting Up 1 Ensure the PCO Power Connector is properly seated in the PCO Cell Power Connector Outlet see DISASSEMBLY ASSEMBLY pages 15 16 2 If the PCO still fails to operate it needs to be replaced Contact your distributor or GreenTech Environmental www GreenTechEnv com The Ionization Needle Creates an Electrical Arc 1 The Ionization Needle needs to be cleaned see CLEANING Ionization page 17 Be sure to complete all of the cleaning procedures see CLEANING page 17 every 30 days of operation The Fan Does Not Operate Properly 1 Try adjusting the fan speed using the Control Panel or Remote Control 2 Remove Front Grille see DISASSEMBLY ASSEMBLY pages 15 16 to ensure there no obstructions to the movement of the fan 2 If the Fan continues to operate improperly or not at all contact your distributor of GreenTech Environmental www GreenTechEnv com The Unit Makes a Rattling Noise When Taken Out of Packaging Remove the back panel of unit see DISASSEMBLY ASSEMBLY pages 15 16 Check to ensure the two brass Thumb Screws holding the Filter Assembly ate in their proper place If they ate properly installed remove the Thumb Screws and Filter Assembly see DISASSEMBLY ASSEMBLY pages 15 16 and check the PCO Cell to ensure the two brass Thumb Screws securing the PCO are installed properly C
7. ay Mode button Each press of the Away Mode button adds two hours to the Away Mode Timer Select 2 00 4 00 6 00 or 8 00 hours Press Away Mode once more to switch the unit back to Normal Mode SETUP amp OPERATION LCD REMINDERS Replace Plate When Replace Plate appears the Purification Plate has reached the end of its useful life and must be replaced To order a replacement contact your distributor or GreenTech Environmental www GreenTechEnv com Once a replacement has been obtained follow the instructions in DISASSEMBLY ASSEMBLY to replace your old Purification Plate with your new one Replace PCO Cell When Replace PCO Cell appears the PCO Cell has reached the end of its useful life and must be replaced Contact your distributor or GreenTech Environmental www GreenTechEnv com to order a replacement Once a replacement has been obtained follow the instructions in DISASSEMBLY ASSEMBLY to replace your old PCO Cell with your new one Perform Cleaning Perform Cleaning will display once the 30 day operation cycle between cleanings has passed and the unit requires a complete cleaning Follow the instructions in CLEANING page 17 then see Resetting Reminders below to reset the reminders The Perform Cleaning reminder will appear again after 30 day of operation Resetting Reminders After replacing the Purification Plate or the PCO the corresponding reminders will res
8. dry separately before reassembly When reassembling the Honeycomb Filter goes in first then the Foam Filter and finally the thin Mesh Filter Lastly reattach the rim to the Fier Assembly Cleaning the Ionization Needle Using a cotton applicator Q tip apply a small amount of clear alcohol based cleaner or rubbing alcohol to the Ionization Needle You may also use compressed air to blow off any dust that may accumulate near the ionization needle Cleaning the PCO Cell Using a compressed ait a vacuum cleaner blow and or vacuum the dust out of the PCO Do not use any liquid to clean the PCO Cleaning the Purification Plate Using a 50 50 mix of warm water and clear ammonia soak the Purification Plate for 8 10 hours but do not exceed 12 hours Using a soft bristle brush scrub the wite mesh to remove debris lodged inside the mesh Rinse thoroughly Allow the purification plate to dry completely before reinstalling After reinstalling use a soft cloth and rubbing alcohol to clean the contacts on the interior of the unit that touch the Purification Plate CLEANING THE UNIT INTERIOR Using a damp cloth a clear alcohol based cleaner compressed air or a vacuum cleaner carefully clean the walls and components inside of the unit only after completing the Disassembly procedures 17 TROUBLESHOOTING The Unit Fails to Turn On 1 Verify that the Power Plug is plugged into an operational wall outlet Ensure that the Powe
9. during reassembly Remove the Front Grille carefully to ensure that the Ionization the top center of the front of the unit is not damaged Clean the Front Grille if necessary using compressed air vacuum cleaner damp cloth or warm soapy water and set the Front Grille aside Clean the Ionization Needle if necessary see CLEANING Ionization Needle DISASSEMBLY ASSEMBLY ASSEMBLY Refer to Tools amp Workspace from Disassembly Section Installing the FRONT GRILLE 1 Gently put the Front Grille in place on the front of the unit being careful not to damage the Ionization Needle at the top center of the front of the unit 2 Insert the four Front Grille Screws one at a time until they are in place but not tight After all four Front Grille Screws are in place tighten them carefully Installing the PCO CELL 1 Position the PCO inside the unit so that the two tabs are on the bottom and interior side of the PCO Ensure the holes in the two tabs fit over the two Screw Posts Screw the Thumb Nuts onto the Screw Posts until they are snug 2 the PCO Cell Power Connector to the PCO Power Connector Outlet and insert gently until the tabs at the top and bottom of the PCO Cell Power Connector snap into place holding it in the PCO Power Connector Outlet Installing the PURIFICATION PLATE 11 Holding the Purification Plate by the ceramic slowly insert it into the Purification Plate
10. er flat against the rear of the unit until the tabs on the sides of the Rear Cover click into place on the unit 2 Carefully insert the Rear Cover Screw into its hole on the Rear Cover above the Power Cord Pori and tighten Installing the POWER CORD 1 Insert the Power Adapter Plug into the rear of the unit 2 Ensure the Power Cord is properly connected to the Power Adapter 3 Insert the Power into a wall outlet Turning the unit on 1 Press the power button 2 The unit will be set to Normal Mode once again Ensure that the uni s settings are adjusted to suit the environment see Operations on page 13 CLEANING Your unit should be cleaned monthly to be kept running at peak performance but depending upon the pollution or odor levels present during initial setup it is advisable to clean the unit more frequently weekly or bi weekly until the environment has been treated CLEANING THE UNIT EXTERIOR Wipe down the exterior with a damp cloth or use compressed air or a vacuum cleaner to remove dust Use an alcohol based cleaning product to clean the surfaces of your unit Cleaning the Filter Assembly You may use clean water or compressed air to clean your Fi ter Assembly once it has been disassembled see Dazsassembly Removing the Filter Assembly After disassembling your unit the three filters mesh foam and honeycomb should be removed and cleaned separately If using water you must allow the filters to
11. et themselves After performing a cleaning of the unit see CLEANING page 17 you should reset the reminders by holding down the Reset Reminders button on the Control Panel of the unit The reminder has been reset when Perform Cleaning no longer appears Copyright 2011 GreenTech Environmental All Rights Reserved 14 DISASSEMBLY ASSEMBLY DISASSEMBLY Tools Reguired You will need a 2 Phillips screwdriver Workspace Recommendations A countertop or flat surface is ideal for disassembling assembling your unit You will need 2 ft x 3ft of clean accessible workspace It is recommended to use a small bowl or cup to hold any screws so they are not lost during the assembly process Disassembly Instructions 1 2 3 Turn the unit off Remove the Power Cord from the wall and rear of the unit Clean exterior of unit if necessary see CLEANING Unit Extenor page 17 Removing the Rear Cover 1 Using your screw driver remove the Rear Cover Screw from the Rear Cover above the Power Cord Port Place the Rear Cover Screw where you will find it easily during reassembly Squeeze the tabs on both sides of the Rear Cover where the grooves are until they release and tilt the Rear Cover upwards until the top tab releases Clean with compressed air or a damp cloth Set the Rear Cover aside Removing the Filter Assembly 1 Remove Brass Thumbscrews from the top corners of the Assembly Place Brass Thumbscr
12. ews where you will find them easily during reassembly Grasp the top of the Fiter Assembly and tilt away from the unit Clean if necessary see CLEANING Filter Assembly page 17 and set the Fi ter Assembly aside Lift tabs on either side of Filter Assembly to remove the rim and access the separate honeycomb foam and mesh layers Removing the Purification Plate Grasp the Purification Plate on the ceramic and gently pull it out of the grooves on the sides Clean see CLEANING Purification Plate page 17 and set the Purification Plate aside Removing the PCO Cell 1 Locate the PCO Cell Power Connector on the right of the rear of the unit almost halfway up the unit beside the Purification Plate slot Squeeze the tabs on the top and bottom of the PCO Cell Power Connector and pull gently until free from the PCO Cell Power Connector Outlet Remove the Thumb Nuts from the Screw Posts on the right and left below the PCO Cell Place the Thumb Nuts where you will find them easily during reassembly Gently slide the PCO Cel out of the unit Clean see CLEANING PCO page 17 and set the PCO Cel aside Clean the interior of the unit see CLEANING Unit Interior page 17 Removing the Front Grille 1 15 Locate the four Front Grille Screws in the four corners of the Front Grille Using your screw driver carefully remove the four Front Grille Screws Place the Front Grille Screws where you will find them easily
13. fore using the unit you will need to find the area or square footage of the environment To do this accurately take into account all connected rooms with open doorways the purification does not flow readily through closed doors The GT3000 can purify up to 3 000 square feet of space For example Suppose you have a 2500 square foot house The living room 1s attached to the kitchen three bedrooms the den and a laundry room The kitchen and three bedrooms doors remain open the majority of the time but the laundry room and den usually remain closed off from the rest of the house Together the laundry room and den have a combined area of 500 square feet The area of the environment you would want to set your GT3000 and purify would be 2000 square feet Copyright 2011 GreenTech Environmental All Rights Reserved 12 Once you have determined an ideal location for your unit and calculated the area of the environment 1 Connect the Power Cord to the Power Adapter and the Power Adapter Plug into the unit Check to be sure your power supply is properly assembled The Power Cord should be inserted far enough into the Power Adapter so that a space of only about 1 8 in is left between the widest part of the power cord and the edge of the Power Adapter 2 Insert the Power Plug into the wall outlet 3 Turn the unit on and set it to NORMAL mode see CONTROLS 4 Leave the unit on NORMAL mode for at least 24 hours to begin with 5 Af
14. ier including any warranty of merchantability or any warranty for Fitness For A Particular Purpose is limited to the duration of this warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you Your relief for the breach of this warranty is limited to the relief expressly provided above In no event shall GreenTech Environmental be liable for any consequential or incidental damages you may incur in connection with your purchase or use of the Air Purifier Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This Warranty gives you specific legal rights and you may also have other rights which vary from state to state Registration Please register your new GreenTech Air Purification product within 10 days of purchase by visiting www GreenTechEnv com warranty or fill out and return the enclosed warranty registration card Registering your new GreenTech product entitles you to the most up to date GreenTech product warranty and promotion information RECORDS PURCHASE DATE MODEL NUMBER SERIAL NUMBER DISTRIBUTOR NAME DISTRIBUTOR PHONE Copyright 2011 GreenTech Environmental All Rights Reserved CONSUMER INFORMATION GreenTech Environmental declines all responsibility for all damages arising from improper use of the unit or in case of tampering with the un
15. it SPECIFICATIONS Unit Size 12 high x 9 wide x 12 deep Weight 10 2 Ib Coverage 250ft to 3000ft 23m to 279m Power Cord Fuyuang Switching Power Supply Model FY3803000 Input 100 240VAC 50 60Hz 2 5A Output 38VDC 3A See the power supply label for certifications and warnings PCO Cell Normal Mode Output lt 0 02 ppm ozone ambient room concentration Purification Plate High Mode Output 25 360mg ozone per hour Ionization Needle 24 to 30 KV 20 30 Khz Ion Generation Pulsator 6 KV DC Needle Ion Generator Depending on variables such as the severity and frequency of pollution flow of air in the environment humidity and temperature WARNINGS Review this list before use and performing any maintenance or cleaning of your unit WARNING gt WARNING gt CAUTION gt CAUTION gt CAUTION gt CAUTION WARNING Never operate unit near heat source open flame or flammable combustible fluids WARNING Do not operate unit unless all parts including PCO Cell Purification Plate Rear Filter Assembly and Rear Cover are properly installed CAUTION Directly viewing the lamp inside unit for an extended period longer than 20 min may result in eye damage CAUTION Never adjust setting to exceed square footage of ventilated space being treated CAUTION Do not use AWAY MODE in occupied spaces Short term exposure to ozone levels exceeding 0 5 ppm can cause temporary adve
16. m to attract other particles and clump together As more and mote particles come together they become heavier making them easier to pull into the home s HVAC air filter or just fall to the floor to be vacuumed up Unlike HEPA filters that can only filter out particles of 5 microns or larger the ionizer in the GT3000 can reduce ultra fine even nano particles that are much more dangerous than the larger particles you can actually see Scalable Purification The system allows for adjustable purification settings in order to accommodate the specific needs of the user at the time Using these settings will help your machine provide optimum performance appropriate for its environment In High Mode the purification plate generates activated oxygen to assist in breaking down contaminates which cause odors For faster cleanup the machine can be set to Away Mode which has a programmable auto shutoff timer feature This allows the machine to generate maximum output when the room or home is unoccupied Electrostatic Filtration An advanced electrostatic filter is included with the GT3000 to help keep the purifier clean while at the same time filter out the clumped particles See Needlepoint Ionization Several layers of media make up the filter The friction created by these layers and the particles filtering through them creates a negative charge further attracting particles and directing them into the filter Unlike expensive HEPA filters the elect
17. opyright 2011 GreenTech Environmental All Rights Reserved 18 NOTES MAXIMIZE THE EFFECTIVENESS OF YOUR GT3000 WE RECOMMEND THE COMBINED USE OF OUR OZONE PLATE GLEANING KIT HARSH ENVIRONMENT PRE FILTERS BENEFITS OF THE OZONE PLATE GLEANING KIT ASK YOURSELF IF YOUR ENVIRONMENT IS Deeper more effective cleaning than scrubbing e an Indoor Smoking Area Convenient and simple cleaning procedure e a Habitat for Multiple Pets e Dramatically increased ozone plate lifespan e a Commercial Kitchen with Airborne Grease Three replacement plates and safe plate storage e a Shop with Airborne Dust Paint or Grease Less frequent handling of harsh chemicals or a Heavily Polluted Contaminated Area SO YOU SHOULD USE HARSH ENVIRONMENT PRE FILTER USING A HARSH ENVIRONMENT PRE FILTER IN THESE CONDITIONS CAN VOID YOUR MANUFACTURERE S WARRANTY
18. r Cord is fully inserted leaving less than an 1 8 to the Power Adapter Ensure that the Power Adapter Plug is fully seated in the receptacle on the back of the unit Verify the Power Button has been activated on the Control Panel If the Power Button the Control Panel fails use the Power Button the Remote Control the Control Panel fails contact your distributor of GreenTech Environmental www GreenTechEnv com The Unit is Operating in High Mode or Away Mode but No Noticeable Purification is Being Produced Ensure that the Purification Plate is clean see CLEANING Purification Plate page 17 Purification Plate may not be working because it needs to be replaced Try installing a new Purification Plate Check the electrical contact arms which touch the plate to ensure that they are making proper contact with the metal weave on the Purification Plate Ensure the electrical contact arms which touch the plate are clean Clean them with a soft cloth and rubbing alcohol R Turn the lights off in the room and look through the Front Grille at the Purification Plate If it is operating properly it will produce dim purple glow The Purification Plate Generates an Electrical Arc an Arcing Noise or a Burning Odor This means the Purification Plate is damaged and must be replaced The unit may or may not display the Rep ace Plate LCD reminder To order a replacement contact your distributor or
19. rostatic filter is washable and can be used over and over again DIAGRAMS UNIT Front of Unit Rear of unit Side of Unit 4 4 4 4 4 4 4 4 4 4 i 4 4 1 7 IONIZATION NEEDLE 7 REAR COVER SCREW 7 REAR COVER 2 FRONT GRILLE 2 REAR COVER CLASPS 2 UNIT REAR CONTROL PANEL POWER ADAPTER INLET UNIT FRONT Copyright 2011 GreenTech Environmental All Rights Reserved 8 UNIT Rear of Unit Rear Cover Removed Rear of Unit Filter Assembly Removed Power Supply AVERTISSEMENT BRASS THUMBSCREWS PCO CELL POWER CORD FILTER ASSEMBLY PCO CELL NUTS POWER CORD PLUG 9 69 O FILTER ASSEMBLY CLASPS 9 9 9 PURIFICATION PLATE POWER ADAPTER PLUG PCO CELL CONNECTOR POWER ADAPTER 9 DIAGRAMS CONTROLS Remote Control Panel DO Oe PURIFIER REMINDER PURIFIER AWAY MODE NORMAL HIGH Soe V S NORMAL AWAY HIGH MODE FAN LEVEL CONTROL SLEEP MODE CONTROL 7 POWER BUTTON 7 POWER BUTTON 5 PURIFIER LEVEL CONTROL PURIFICATION LEVEL CONTROL 2 FAN SPEED CONTROL 6 AWAY MODE TOGGLE NORMAL HIGH MODE CONTROL INFRARED RECEIVER NORMAL HIGH TOGGLE AWAY MODE CONTROL REMINDER RESET BUTTON Copyright 2011 GreenTech Environmental All Rights Reserved 10 CONTROLS Control Panel Screen AREA MUST BE UNOCCUPIED 7 FAN SPEED INDICATOR MODE IN
20. rse reactions CAUTION Unit should be powered OFF and Power Cord should be disconnected when Cleaning Disassembling Reassembling Servicing PRODUCT INTRODUCTION BENEFITS The GT3000 air purifier system brings the most advanced air purification technology into the comfort of your home Unlike other air purifiers the GT3000 does more than simply filter the air in your space Incorporating technology like photo catalytic oxidation high level negative ionization scalable purification and electrostatic filtration allows the air purification system to provide tangible benefits to your home or workspace by e Destroying pollution from the air embedded in walls ceilings floors carpets furniture etc Reducing eliminating odors such as cigarette smoke mildew food etc Contributing to sanitization of all surfaces within home 5 The whisper quiet five speed fan disguises the power encapsulated in the advanced air purification system Having GT3000 in your home will not only improve the quality of air but most importantly it will improve the quality of life EASE OF USE The GT3000 is your hassle free provider for clean air and healthy living With proper care and maintenance see CLEANING page 17 GT3000 will operate with the same robust power and efficiency for several years beyond the date of purchase With the push of a button the GT3000 starts working to eliminate the biological contaminates
21. ter 24 hours set the unit to HIGH mode and set the square footage to 250 square feet 6 Gradually increase the square footage setting every 8 12 hours until you reach the accurate square footage of your area which you calculated in the beginning steps Note Using the purifier at a setting less than the square footage of the area being treated is acceptable and may be desirable in an environment relatively free of pollutants OPERATING THE UNIT Turning the Unit On Off Press the Power Button on the Control Panel or Remote to turn the unit on The unit will initially be set to Normal Mode Press the Power Button once more to turn the power off Using Normal Mode Press Normal High button until Norma is shown in the lower right of the Display Square Footage not available in Normal see INITLAL SETUP Initial Settings page 12 control the fan speed Use Fan Up Down buttons Using High Mode Press the Normal High button and verify that High is shown in the lower right of the Display set the square footage on the Display Use Purifier Up Down buttons See INITIAL SETUP Initial Settings page 12 To control the fan speed Use Fan Up Down buttons CAUTION Never adjust setting to exceed square footage of ventilated space being treated Using Away Mode Press the Away Mode button and verify that Away is shown in the lower right of the Display To set the Away Mode Timer press the Aw
22. tions caused by negligence abuse or use not in accordance with the Owner s Manual are not covered by this warranty Likewise any defects or damages caused by unauthorized service or the use of other than Genuine GreenTech parts are not covered GreenTech will at its option repair or replace a defective Air Purifier or part s for the Air Purifier that is covered by this warranty As a matter of warranty policy GreenTech will not refund the customer s purchase price To register your warranty please visit www GreenTechEnv com warranty or fill out and return the warranty registration card that came with your Air Purifier To obtain warranty service you must return the defective Air Purifier or Air Purifier parts along with proof of purchase to the GreenTech Authorized Warranty Station All transportation charges on parts or units submitted under this Warranty shall be borne by purchaser Unless this Warranty is expressly renewed or extended by GreenTech Environmental any repaired or replaced part of unit shall be warranted to the original purchaser only for the length of the unexpired portion of the original warranty For the location of the nearest GreenTech Authorized Warranty Station or for service information in the United States or Canada please visit us online at www GreenTechEnv com Further Limitations And Exclusions Are As Follows Any warranty that may be implied in connection with your purchase or use of the Air Purif