Home
User Guide
Contents
1. STEP 07 The existing light should be detached from electrical framework STEP 08 Since the existing light is also hung on the T bar frame lift it in the direction shown in the figure STEP 09 Rotate the existing light in a diagonal direction so it can be taken out of the T bar frame Make sure all wires and cables are disconnected For safety this should be per formed with the power switch off Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 E Bela Recessed LED Panel Light Installation amp Operation User Guide install Light Panel STEP 10 Lift Bela carefully by holding as shown in the figure STEP 11 Since the size of recessed light panel is larger than the retrofit area position it inside the ceiling by rotating it slightly in a diagonal direction STEP 12 n Properly align and fasten safety clips to the T bar frame To do so temporary removal of neighboring ceiling panels is recommended Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 W Bela Recessed LED Panel Light Installation amp Operation User Guide Connect AC Power STEP 13 Upon removal from packaging the SMPS should be completely housed as shown in diagram STEP 14 Installer has options for SMPS access as shown in the figure The various opening caps are designed to be detached after loosening holders with a sm
2. facturer shown in the top diagram is used The information in this document is subject to change without notice Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 D Bela Recessed LED Panel Light Installation amp Operation User Guide 1 Set the master 112 4 0 Press On Off repeatedly Minimum 3 times Set fixture to Off mode 11324 Press Button1 Red for 3 seconds The fixture is Ready for setting and will blink 18 2 XI Press Button3 Blue then press the Recall Button alternately 3 times 21444 Press Save button The fixture will blink once informing the user that the setting is complete Note All Bela recessed LED light panels are factory set to the Slave mode Assign master functions as necessary 2 Release the master 11 348 Press On Off repeatedly Minimum 3 times Set fixture to Off mode Cgi 2 4 Press Button Red for 3 seconds The fixture is Ready for setting and will blink lt 3 i KI Press Recall button once 14X Press Save button The fixture will blink once informing the user that the setting is complete 3 Control the IR brightness c C C The luminosity is increased decreased up to 10 levels by pressing the Up Down button e q O 6 Press Left Right button to set fixture to either min max luminosity Q2 The information in this document is subject to change without notice Copyright 1991 2012 KMW All Righ
3. all amount of force STEP 15 After detaching the appropriate cap from the cover pull out AC cables from the SMPS housing Below is the breakdown of the colored wiring e Black Brown AC L e White Blue AC N e Green Yellow F G Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 E Bela Recessed LED Panel Light Installation amp Operation User Guide A wire cover may be installed to protect cables as shown in the figure The wire cover is not included in the package and should be purchased separately if needed STEP 17 Connect AC line first to the power connector The figure on the right is only an example The connection status of the power supply cable may vary depending on the condition of site The power connector is not included in the package and should be purchased separately if needed STEP 18 Lastly test the fixture after connecting the power connector to the main power supply The power connector is not included in the package and should be purchased separately if needed Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 B Bela Recessed LED Panel Light Installation amp Operation User Guide pnnect Communication Cable STEP 19 If there are connection ports for RJ 11 cables in the SMPS the product has a master slave function The recessed LED light panel can be connected to up to 254 fi
4. eful not to damage the product by penetrating too deeply with cutting instrument STEP 02 Open the box widely to take out the product easily Remove packing materials from each corner carefully STEP 03 Grip fixture by the areas shown and place it on a work table Before putting the product on the table we recommend spreading a soft cloth first to prevent damage to the panel Fixing clips should be mounted on the back of the product Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 Bela Recessed LED Panel Light Installation amp Operation User Guide astening Clips STEP 04 First fasten the safety clips on the back of the product On the 4 corners of the recessed light panel there are assigned holes for safety clips to be installed as shown in the figure STEP 05 Mount fixing clips onto the assigned holes with the screws provided as shown in the figure Mount fixing clips on the 4 corners in the same Way Please note that the curved side should be facing outward STEP 06 The recessed light panel is ready for installation with the 4 safety clips installed as shown in the figure The information in this document is subject to change without notice Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 E Bela Recessed LED Panel Light Installation amp Operation User Guide Remove the existing light
5. erter terminal box The 1 10V dimming Bela recessed LED light panel version does not come standard with a group dim ming cable The information in this document is subject to change without notice Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 B Bela Recessed LED Panel Light Installation amp Operation User Guide 5 Battery ESB 3 Fixing Clip 4 Remote Control R817 RJ 11 Cable Detail Description CO CENE D Bela Recessed LED Light Panel 2 Converter Power Supply Unit Fixing Clip Clips for fixing T bar frame Remote Control R817 IR remote control for brightness control Option 5 Battery Battery for the remote control Option Remote Control Rest Remote control rest for wall mounting Option Double sided Tape For mounting the remote control rest on the wall Option RJ 11 Cable Communication cable for master slave operation Option Group Dimming You will need RJ 11 cable for IR or DMX512 group dimming The RJ 11 cable amp remote control is purchased separately from manufacturer The information in this document is subject to change without notice Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 B Bela Recessed LED Panel Light Installation amp Operation User Guide Product Removal STEP 01 Place the box on a flat surface and cut the sealed flaps with a cutter At this time be car
6. http www kmwgigatera com Installation amp Operation User Guide Product Installation amp Operation User Guide EI T Bar Panel Lighting 2x2ft Bela 40W ASW OOW V beyond the light Safety Precautions Installation This symbol is intended to remind the user the presence of actions and operation that may cause danger Please read instructions carefully and follow the instructions to avoid any danger 9 This symbol is intended to represent precautions that the user should follow to prevent danger WARNING Serious injury might result if the following precautions are not followed country region e Never modify or disassemble LED lighting arbitrarily because it can cause serious accidents e Never use any input power except the listed rated voltage If not it can cause serious accidents K e The installation should be performed by certified workers under the relevant regulations of end user s e The wiring should be insulated under end user s respective region s Electric Installations Standards e Do not install in a wet environment 9 e Before installation shut off the power supply and verify it is de powered using a measuring instrument CAUTION The user may be injured or there would be property damage if the instructions below are not followed e Do not use this product for any purposes other than what s specified The manufacturer or sellers are not responsible for breakdowns or accident
7. n User Guide IR Converter AC Input Black Brown L White Blue N LED GND CONVERTER LED VCC OUT Green Yellow FG IN IR RS 485 IR Remote Control Group Dimming LED Panel Lighting Master Slave 1 Slave 2 Slave 3 Slave 4 Slave n Panel Lighting o Group 1 i Group Max 254 LED Lightings 0 0 0 IR Remote Control KMW R817 KMW K13C20 gt RJ 11 6P4C 6pin 4core Telephone Line Connector amp Cable Master slave 1 Slave 2 Slave 3 Slave 4 Slave n Panel Lighting Group N Group Max 254 LED Lightings The information in this document is subject to change without notice Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 E Bela Recessed LED Panel Light Installation amp Operation User Guide DMX 512 Converter AC Input Black Brown L White Blue N LED GND LED VCC Green Yellow FG CONVERTER OUT IN IR RS 485 DMX512 Control LED Panel Lighting DMX512 S elo ola OOOO YU Wall Dimmer Ltech LT 3200 DMX51 2 Group 1 Group Max 254 LED Lightings Panel Lighting e elo ole 0190 9010 DMX512 RJ 11 6P4C 6pin 4core Telephone Line Connector amp Cable Wall Dimmer Panel Lighting Group N Group Max 254 LED Lightings In the case of implementing a DMX512 dimming control system it is advised that the wall dimmer model manu
8. nce is controlled by provided IR Remote 3 Description Function The Bela LED recessed light panel is the ideal retrofit solution for fluorescent lights in offices meeting rooms hospitals Seminar rooms schools and stores The Bela recessed light panel disperses a completely even light output The Bela is glare free and up to 10 levels of luminance is controlled by the IR remote control or DMX512 It composition of light materials allows ease of handling and installation Bela 2x2 and has 3 models 40W 45W and 50W Users are able to choose between 5 different color tem peratures 3500K 4000K 5000K 5 00K and 6500K When fluorescent lights of 80W FL20W x 4 lights are replaced with Bela 40W users are able to save 50 on energy cost and can expect lower maintenance costs due to its longer life span i e 50 000 hours Product Features 1 Environmental Forward LED fixtures use an environment friendly light source that doesn t contain mercury which is a harmful component of fluorescent lights 2 Energy saving amp Longevity The light source of LEDs is a semiconductor device and it ensures reduced power consumption and longer life GigaTera s fixtures add an extra energy incentive because it can control brightness depending on room conditions user preference 3 Design Its elegant design improves the aesthetics of any interior environment 4 Lighting Control Users can control the ON OFF functions not only by using the IR remo
9. s caused by its improper use 3 e Do not forcefully pull on AC DC lines when wiring up the lighting It causes the wires to snap Do not install in a wet environment e Make sure to ground fixture by contacting it to metals around it to prevent damage by static e The product may be damaged if static is not removed e During the operation be careful not to disconnect the wires e Make sure the grounding is performed under Electricity Standards e Using it for any voltage other than specified can cause failure or fire e Do not use it in moist environment e Be mindful of proper ventilation of product e Improper installation or disassembly causes a deformation or breakdown of the product e Consider proper protection devices such as circuit breakers fuses switches etc for safety precautions e Do not install in an enviroment with excessive vibration e Do not handle product with contaminated hands or gloves e n any event do not store install in a contaminated place 9 e When connecting the wires use proper connection terminals depending on the site of installation Bela Recessed LED Panel Light Installation amp Operation User Guide roduct Overview 1 Scope This manual explains the composition installation and operation of the Bela LED recessed light panel 2 Recessed LED Light Panel The Bela LED recessed light panel is designed as a complete retrofit new installation for any indoor applica tion Illumina
10. te control but also by using the DMX512 which enables dimming function as well The information in this document is subject to change without notice Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 KJ Bela Recessed LED Panel Light Installation amp Operation User Guide Checklist before Installation 1 The length between T bar and actual ceiling At least 3 94 2 Size Specs Please refer to the figure below 3 Others Weight load capability of T bar framework should be verified before installing the Bela recessed led light panel 23 62 Space for fixed frame 4 When the installation is complete Recessed light panel is fixed hanging on the T bar frame of a ceiling 23 03 The information in this document is subject to change without notice Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 amp Bela Recessed LED Panel Light Installation amp Operation User Guide RN n l Nu LU 2 e a vcr Ls f 9 Fixing Clip Detail Description LEN CENE pas D Bela Recessed LED Light Panel 2 Converter Power Supply Unit Fixing Clip Clips for fixing T bar frame Group Dimming To set up the 1 10V wall dimming function minor electrical wiring would have to be done using an AWG 20 wire Attach one end of the wires to their corresponding terminals located on the products s conv
11. ts Reserved Document Revision V0 61 2012 09 19 Document Revision v0 41 Bela Recessed LED Light Panel Remote Controller User Guide 1 The brightness can be set from 1 min to 10 max a total of 10 levels 2 The brightness of Button 1 2 3 and 4 are not allowed to be changed arbitrarily because they are given values 3 A 10 sec rest period is recommended after repeated on off modes 4 5 meters 16 4ft is the recommended IR remote parameters 5 When operating the IR remote it is recommended to operate near the master fixture If not other unwanted fixtures may be activated at the same time 6 Press and hold On Off button for 1 sec to allow intended function How to use a Remote Control Model R817 otepwise BRGT M Increase 10 levels 1 10 Turn Off Fixture Select the Max BRGT Luminosity 10 Turn On Off Fixture Select the Min BRGT ic Luminosity 1 Stepwise BRGT M decrease 10 levels 10 1 Set Luminosity to 4 No Setting Value No Setting Value e Luminosity Level 1 more Dimmer Luminosity Level 10 more Brighter RF amp Microwave Products S RF amp Microwave Products The Global Leading RF amp LED Provider For America 1521 E Orangethorpe Ave Ste A Fullerton CA 92831 U S A 1 714 515 1100 salesfakmwgigatera com 183 6 Yeongcheon ro Dongtan myeon Hwaseong si Gyeonggi do Korea 82 31 370 8720 chriskimfakmw co kr
12. xtures with the whole group being able to be controlled by one master fixture STEP 20 Connect master unit to slave unit by using provided RJ 11 cable Insert the RJ 11 cable to the output terminal of the SMPS and connect the other end to the input terminal of first slave unit Repeat as necessary e The right port Input terminal e The left port Output terminal The information in this document is subject to change without notice Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 E Bela Recessed LED Panel Light Installation amp Operation User Guide Schematic amp Dimming 1 10V Converter AC Input Black Brown L White Blue N Green Yellow FG CONVERTER LED GND 1 10V Control LED Panel Lighting Wall Dimmer Lutron 1 10VDC Interface Group 1 Group Max 32 LED Lightings Panel Lighting Wall Dimmer Panel Lighting Group N Group Max 32 LED Lightings In the case of implementing a 1 10V dimming control system it is advised that the wall dimmer model manu facturer shown in the top diagram is used The maximum quantity at the time of group control is according to dimmer switch and acturator supply wattage The information in this document is subject to change without notice Copyright 1991 2012 KMW All Rights Reserved Document Revision V0 61 2012 09 19 Bela Recessed LED Panel Light Installation amp Operatio
Download Pdf Manuals
Related Search
Related Contents
GUIDE DU MEUBLE DE TOURISME User Manual - Projector Central Operating Instructions 5“ Coin Validator 取扱説明書 - 株式会社うき Troubleshooting The reticle is blurry and not in focus Make sure the Indice delle lezioni Samsung MW86N Käyttöopas (XP) Aufstell- und Bedienungsanleitung Instructions for Expressionist MIDI-CV Converter User`s Manual Copyright © All rights reserved.