1. USER MANUAL ENGLISH Welcome new Poseidon divers Here at POSEIDON we are very pleased that you have chosen one of the world s foremost diving regulators POSEIDON has been developing regulators for divers since 1958 Professional divers military divers and techdivers choose POSEIDON equipment because of the high demands they place on our products the same demands you have Your new regulator has been designed to provide you with a life time of pleasure as a POSEIDON diver Our objective is that the equipment you are wearing should not be noticeable instead it should be at one with the experience and give you total freedom to achieve what every diver dreams about the ultimate dive To be at one with the water To have full control and at the same time feel the weightlessness when meter by meter you descent into a world of your own Nothing shall disturb your concentration No wheels or levers that need adjusting No regulators that resist your breathing when you have reached your target depth No suits that limit your freedom of movement or get damaged at the slightest encounter This vision has accompanied Poseidon since the legendary diving enthusiast and engineer Ingvar Elfstr m started the company in the late 50 s The same ideas motivate us now The name Poseidon represents constant development and improvement of diving equipment where everything is positioned correctly and everything functions even in the most extreme situat
2. different for different models or if any faults are detected a service Level B is required which is a complete overhaul You can do some fault correcting servicing and or preven tive servicing yourself Following the instructions which co mes with the spare part you are allowed to Replace the diffuser Replace the mouthpiece Replace the hose m 26 XSTREAM sid USER MANUAL ENGLISH Modifications of the product are prohibited Modifications can impair the function of the regulator and transfers the responsibility to the person who does the modification Adding decals and other outer means for oxygen Nitrox identification as well as marking with a pen is not regarded as mo difications WE INTEND TO CO DIVING EQUIPMENT DROPOF NTINUE TO PRO AS LONG ATERREMAINS IN Box 8050 S 421 08 V stra Fr lunda SWEDEN t 46 0 31 7342900 f 46 0 31 7342901 www poseidon se Art no 4695 ISSUE 040924 3
3. the system from compression shocks Rapid openings repre OXYGEN ALERT sents the highest risk for fire due to compression shock To ensure a slow opening it is good practice to use both hands one on top of the other Always open the cylinder and isolator valves if used first fully and then a 1 2 turn back Partly opened valves in WARNING creases the pressure drop over the valve and can reduce the performance On some brands valves that are almost closed can even shut off during a dive due to internal flexing of materials 5 Press a few times on the purge button on the second stage so as to blow out possible debris 6 Check the pressure gauge to see that the tank is full HE ULTIMATE DIVE A EE z 16 XSTREAM whilst purging by watching the almost zero deflection of the needle this indicates that the air is flowing correctly with no restrictions 7 Test breathe through the regulator and the octopus If the gas smells or tastes bad do not dive with it Tip You can test the regulator s correct setting by partly immersing the 2nd stage in water see picture The servo valve should crack open when the regulator is immersed in between the two positions shown Tip At dives where the water conditions are very cold or there is an apparent risk for hypothermia i e at Trimix dives or water temperatures lt 10 C 50 F it is recommended to use the surgical cord around the neck for the regulator being used Th
4. Xstream Deco is available as Deco EN 144 3 This confi guration comply with the new European standard EN 144 3 for outlet connections for Oxygen Nitrox gases DURATION DURATION EN 144 3 1 ST STAGE EAN AIR Duration shares the performance and specifications from Deco but is identified by colour and approved for use with EAN mixes up to 50 oxygen The side mounted hand wheel versions represents a higher risk for ignition using elevated oxygen contents due to the 90 degree turn of the high pressure gas flow If you prefer the 3 IP ports and such a configuration of your equipment and you do not plan to use mixtures greater than 50 Duration is the regulator for you The green colour coded Duration is offered for your safety at the dive site and during the dive avoiding the risk of mixing up regulators for different gasses Both Duration models side and bottom mountd are availa ble in EN 144 3 configuration ng XSTREA o USER MANUAL ENGLISH DIVE 1 ST STAGE AIR Dive shares the performance and specifica tions from the other Xstream 90 models It is identified by the chrome plated T D A top and the number of outlets 5 low pressure and 2 highpressure Xstream Dive is delivered with a 70 cm hose but all hoses available for the Xstream regulator also fits the Xstream regulator XSTREAM LP HOSES All Xstream hoses are made of high quality SBR NR and are available in different lengths For deep dives or in par
5. breaking the surface Leakages at extremely cold conditions There is a sound from the regulator Gas vents from 2r4 stage on opening the cylinder valve Check the cracking pressure see sec tion 6 2 The sound is occur ring even while diving Does it stop within 1 2 se conds If the crack ing pressure is too low it increases the risk for free flow If the re gulator hits the surface at a certain attitude it can start a free flow Incorrect o rings Incorrect lubricants have been used Have the re gulator cor rectiy set by an authorised dealer Either im merse slowly keep regulator in your mouth or hold your hand over the free mouth piece while entering the water Have the regu lator serviced by an autho rised dealer require o ring replacement Have the regu lator correctly lubricated by an authorised dealer If yes it is normal that max 3 litres of air is used to en gage the servo mechanism If no the cracking pressure is too low which increases the risk for free flow USER MANUAL ENGLISH OXYGEN STATEMENT In diving operations the use of oxygen is essential for the human metabolism In addition oxygen concentration levels greater than in air can improve safety especially but not only by lowering the risk for DCS and Nitrogen narcosis The Poseidon Xstream Deco Deco EN 144 3 is approved for use with gaseous oxygen up to 99 95 pu
6. hose will bleed off the excessive gas This system both indicates to you that something is wrong so that you can take action and because of the up stream servo valve tech nique allows the regulator to continue to breath normally conventional downstream regulators are likely to free flow in such a situation Integrated surgical hose fixing points safely secures the regulator to the diver but in an emergency allows a distres sed buddy to retrieve the regulator without undue stress to the diver The dead air space is low at just 49 5 ml 3 in making CO2 10 XSTREAM 7 gat Patented figures hypercapnia minimal Inhalation resistance is in credibly low and unaffected by depth and breathing pattern Because of the unique Poseidon valve technology there is no need for external adjustments Xstream is fitted with the new ergonomic mouthpiece Posei don AIR with asymmetrical lugs for the most comfortable bite All diaphragms are protected so that a strong current or using a scooter or tug does not affect either inhalation or exhalation A minimal number of moving parts coupled with thermodynamic engineering ensures the safe use in an extremely cold environment XSTREAM 1 ST STAGE The first stage is a balanced rolling diaphragm ball valve producing extreme leaktightness Conventional designs are sensitive to wear misalignment and manufacturing precision A ball always finds its correct place Comb
7. not replace all of the various procedures you have learned in your diving training program Xstream must always be used with minimum the following SCUBA equipment Compressed gas cylinder s conforming to natio nal regulations Frame or holding device for the cylinder s with the possibility to mount the harness A safety system including at least one of the follo wing A submersible pressure gauge A reserve valve An active low pressure warning device 1 Always check the gas content of the cylinder before at taching the regulator 2 Before attaching the regulator carefully open the cylinder valve using gas flow to clear the outlet then close the valve Never direct the gasstream to bare skin or clothes porous materials 3 Remove the protective cap on the first st age Check that the O ring on the regulator s connection is intact and clean then mount the regulator on the cylinder valve Turn the handwheel yoke knob until you feel that the regulator is securely fast ened Inspect the o ring and make sure it is absolutely free from OXYGEN ALERT particles and or grease Do not touch the o ring Grease and particles can cause a fire 4 Slowly open the cylinder valve all the way then turn the knob back half turn When the 2nd stage is pressurised and the servo mechanism engages a maximum of 3 litres of gas vents from the 2nd stage Slow opening of the cylinder valve is the best way to protect
8. Deco DIN 477 G5 8 EN 144 3 EN 144 3 M26x2 Brass plastics stainless steel 0 7 m 2 3 ft 0 9 m 3 ft 1 6 m 5 2 ft 2 15 m 7 ft Pull strength 21000 Newton 225 Ibf Material SBR NR Standard lengths hose EXPLODED VIEWS USER MANUAL ENGLISH BREATHING PERFORMANCE Typical Work of Breathing at Depth EN 250 stops here N un WoB Inhale Exhale WoB Inhale WoB Exhale Limit EN 250 Limit Norsok U 101 1111 Work of Breathing J litre e 0 50 100 150 200 Depth m The diagram above show a calculated graph for Work of Breathing in Joules litre at Q 62 5 litres min The equation behind it is extracted from hundreds of tests from which coefficients for gas dependency average flow dependency and depth dependency is calculated Its maximum inaccuracy is within 10 The equation assumes the most dense gas possible to safely breath is used i e a maximum tolerable pO pN at any depth Adding more Helium will lower the figures It is important to understand that this equation does not apply to any other regulator since the coefficients and cha racteristics are strongly dependent on the regulator cons truction 80 60 50 40 Pressure bar 30 Recommended limit mama Min cylinder pressure 20 mmm Absolute interstage pressure 0 50 100 150 200 Depth msw Full regulator capacity is obtained as long as the cylinder pre
9. IR All materials in Xstream Deep are chosen and tested to be optimised for Helium and high flow This requires special attention to leak tightness since Helium gas has such a low density All o rings are of the highest Nitrile quality and rated for use down to 40 C 40 F Deep 1st stage comes in two different versions One side mounted and one bottom mounted Both versions are certifi ed to 200m 656 ft depth and colour coded black which in most countries represents a bottom gas mix DECO DECO EN 144 3 1 ST STAGE OXYGEN EAN AIR O stands for oxygen engineered oxygen compatible oxy gen clean and oxygen approved Xstream Deco is O It is not just a viton configured air regulator but in detail engi neered for pure oxygen The Xstream Deco cannot be made as a side mounted ver sion since 90 degree turns of high pressure high velocity oxygen represents an elevated risk for heating of the gas due to resonance effects The connection stem is sealed with a pure copper washer sintered onto the filter It has been tested for 360 bar 5221 psi adiabatic com pression oxygen shocks of less than 20 ms heated to 60 C 140 F according to EN 738 1 To make the test even more severe than required it is tested with 99 95 purity of oxygen Directly from the box it is cleaned to NASA Specification 1 Cleaning test Level 100 particle contamination and NVR levels less than ASTM G63 Level C 50 mg m2 hydrocar bons The
10. by medical effects of the gas The oxygen partial pressure must normally not exceed 1 4 bar 20 3 psi under the foreseeable maximum diving depth Only if established oxygen exposure tables are strictly adhe red to and a responsible organisation is planning dives with increased exposures elevated levels can be accepted for a shorter period of time The oxygen partial pressure must never be lower than 0 2 bar 2 9 psi under the foreseeable minimum diving depth The nitrogen partial pressure must not exceed 3 2 bar 46 4 psi under the foreseeable maximum diving depth Inhaling cold gas and exhaling warmed gas represents energy losses of the human body thermal imbalance hy pothermia This effect increases with increasing depth and can result in a sudden unconsciousness Diving to extreme depths this effect must be considered calculated and plan ned for and preventive actions must be taken such as pro per thermal protection and pre heated gas Xstream is for unlimited use in water temperatures from water freezing temperature t 1 C to 50 C 122 F The freezing temperature depends on salt content Diving with gas blends other than air or deeper than 18 m 59 ft or in overhead environment requires special train ing regarding practices equipment physical and medical understanding This manual assumes the reader has some basic knowledge in those respects Diving is a strenuous physical activity Its difficu
11. e mouth region can become numb from cold and you risk loosing the regulator DIVING What is most distinctive about the Xstream is that it is easy to use there aren t any valves or switches to change the flow of gas reducing breathing performance etc You can leave the function and performance of the regulator in our hands and concentrate on what you want to do dive AFTER DIVE The regulator should always be rinsed while it is still mounted on the tank The regulator should be under pressure i e mounted onto the cylinder otherwise wa ter can enter either the first or the second stage and cause the build up of ice during your next dive 1 The regulator should be rinsed in fresh water after every dive so as to avoid salt crystal formation around the func tional parts 2 After rinsing close the cylinder valve and purge the re gulator 3 Unscrew the regulator from the tank Check that the pro tective cap is free from water and debris then mount the protective cap onto the connection The regulator should not be stored in direct sunlight and or at high temperatures Make sure it is never subjected to mechanical shocks or impacts HE ULTIMATE DIVE gt gt 18 XSTREAM ACCESSORIES Xstream can be combined with the following equipment accessories given that the manufacturers instructions for use are strictly adhered to Xstream EN 144 3 rebuild kit Xstream hoses Xstream nec
12. elow 200m on Trimix I min 62 5 Approved gas Dive Air X Duration Air EANSO Deco Air Oxygen_ Maximum working pres 300 bar 4351 psi sure Cold water performance Exceeding EN 250 require ments for cold water use Approvals Type Approved acc to EU Di rective Personal Protective Equipment 89 686 EEC Applicable Performance EN 738 1 clause 6 6 6 6 2 Standards NORSOK U 101 clause 5 2 5 5 5 9 EN 250 2000 Cleaned to hydrocarbon Dive No levels lt 50mg m2 amp par Deep No ticle level X Duration Yes ____ Deco Yes Dive Nitrile EPDM Duration Viton EPDM Deco vitonnEPDM USER MANUAL ENGLISH O ring materials Lubricants Poseidon 1 BAM appr 270 bar 100 C Poseidon 2 BAM appr 140 bar 100 C Poseidon R silicone oil Grey Yellow Deep Warranty 24months Esta IRE Inner Volume 49 5ml 3in Weight I52g 540z 18 1 bar 261 14 psi Around axis can be used either side Venturi assist Automatic Inhalation control Automatic Surgical cord Silicone Flowrate 1 min 24000 l min gt 141 scfm 5 IP UNF 3 8 2 HP UNF 7 16 Deep 2 IP UNF 3 8 Duration 1 HP UNF 7 16 Deco Deep 90 3 IP UNF 3 8 Dur 90 1 HP UNF 7 16 Deep DIN 477 G5 8 Dive Yoke adapter available Duration DIN 477 G5 8 Duration EN 144 3 M26x2 EN 144 3 Deco
13. gen Trimix a gaseous mix containing Oxygen Nitrogen and Helium EAN 50 any gas mixture containing greater than 21 oxy gen up to 50 Enriched Air Nitrox IP Interstage pressure the pressure existing between the 1st stage and the 2nd stage valve HP High pressure the pressure inside the SCUBA cylinders normally ranging between 300 bar 4351 psi to 10 bar 145 psi Scfm standard cubic feet per minute l min STPD standard temperature and pressure dry gas T D A Thermo Dynamic Anti Freeze TH XSTREAM USER MANUAL ENGLISH GENERAL SAFETY REGULATIONS Although the regulator is functional with pure oxygen and has excellent breathing characteristics down to 200m 656 ft the usage is restricted by human limitations or by limitations set out by the dive training organisation whichever is lower Poseidon only warrants the regulator performance as spe cified herein and cannot be held responsible for improper preparations incorrect gas mixing and planning or diving beyond individual medical psychological and physical limi tations Limitations of use Xstream Duration models no higher oxygen content than 50 by volume Xstream Deep models only for use with air or Trimix with a maximum oxygen content of 21 and a maximum Helium content of 77 Xstream Dive and octopus only for use with air and a maxi mum depth of 50 meters Maximum depth never more than 200 meters 656 ft but normally limited
14. ined with the 2nd stage the enormous capacity of the 1st stage make the regulator meet the EN 250 breathing performance requirements even at as low as 16 bar 232 psi cylinder pressure This means that you gain an extra 34 bar 493 psi of gas compared to most other regulators The Xstream construction requires less o rings than any other regulator Except for sealing the blind screws 3 4 there is just 1 sealing o ring semi static in the bottom mounted versions and 2 in the side mounted The hose routing is developed to be optimised for a redun dant system using two regulators The HP ports are positio ned to accommodate the use of gas monitoring computers e g first stage mounted HP sender receive units POSEIDON T D A Xstream has a built in Poseidon T D A Ther moDynamic Anti freeze which requires no maintenance It is always there doing the job It is thermodynamically protecting the parts which must not freeze It is identified by the large slots in the co ver allowing the heat energy of the water to reach the spring The cold from the inside is consequently insulated from the spring via an insulation barrier and insu lating diaphragm It is constructed without compromise to any detail to prevent cold reaching the sensitive area Using Poseidon T D A a regulator can free flow air in fresh water of 0 C 32 F for at least 10 minutes and afterwards still be completely unaffected DEEP 1 ST STAGE TRIMIX A
15. ions Products developed in cold Scandinavian waters that are among the toughest you can dive in If they work here they will work any where Poseidon s devoted followers are convincing proof of that Thank you for your confidence Yours faithfully Registered company Poseidon Industri AB APPROVALS CERTIFICATIONS The Xstream regulator series is approved according to the EU Directive for Personal Protective Equipment 89 686 EEC and meets or exceeds the applicable see Tech nical Data for full detail requirements of EN 250 2000 for cold water diving NORSOK U 101 for diving in excess of 50m depth exclu ding requirements for CO2 content and temperature of inspired gas EN 738 1 for oxygen pressure shocks Type approvement certificate no 020341 020342 and 020343 is issued by SGS United Kingdom Ltd Ellesmere Port CH65 3EN UK Notifi ed body number 0120 Production quality assessment according to article 11 B of 89 686 EEC is assessed by SGS YICS Ltd Portland Road East Grinstead RH19 4ET England Independent performance testing according to directive and standards is conducted at accredited laboratories Di ving and Naval Medicine Centre Swedish Armed Forces and Det Norske Veritas Norway Poseidon Industri AB is certified according to ISO 9001 DNY SS EN ISO 9001 053 EN 45012 DEFINITIONS ABBREVATIONS Oxygen any gas mixture containing greater than 21 oxy gen up to 99 95 oxy
16. is a prerequisite for keeping the risk as low as possible Servicing and cleaning must be carried out by an authorised oxygen service dealer Poseidon has developed and verified a servi cing and cleaning method which guarantee acceptable levels of contaminations Posei don can not be held responsible for the ef fects of other un verified cleaning and servicing methods Failure to adhere to these mandatory requirements trans fers the responsibility to the owner Poseidon will continue to develop products and components which further readuses the risks involved with oxygen use Releasing such products and components is not an admit tance that previously released items must be recalled It is in everyone s interest to always strive for lowering risks ANNUAL SERVIGE It is extremely important for your safety that you keep your equipment in good condition You need not carry out any other maintenance than described in previous section The regulator should be serviced annually and this must only be carried out at one of POSEIDON s authorised service loca tions Look for the POSEIDON Authorised Service Center sign AUTHORIZED Because of the robustness and simplicity of the Xstream construction the amount of servicing is kept to a minimum Normally on an annual basis only a service Level A is re quired which is a functional check visual inspection ac cording to a checklist and filter replacement On a regular basis
17. k strap surgical cord Poseidon Jetstream 2 stage and hose EN 250 Poseidon Jetstream 1 stage EN 250 All CE marked or EN 250 designated cylinder valves Yoke clamp All CE marked approved pressure gauge hoses rated for WP 300 bar using UNF 7 16 connection All CE marked pressure gauges diving computers and HP transmitters senders rated for WP 300 bar 4351 psi All CE marked IP hoses for BCD s and dry suits Xstream feeds 7 5 9 5 bar 109 138 psi to BCD or dry suit All CE and EN 250 marked mouthpieces DIVING GAS Approved gas mixes for Xstream Deep Maximum level of AAA 21 by volume Helium 77 byvolume 500 ppm 35 C 31 F Lubricants droplets mist 0 5 mg m Waer 25 mg m If air is used it shall be according to EN 12021 Approved gas mixes for Xstream Deco Duration Maximum level of i Oxygen 99 95 by volume Deco 50 by volume Duration Co22 500ppm Water dew point 459C 50 F Lubricants droplets mist 0 Gaseous hydrocarbons Solid particles Approved gas mixes for Dive Maximum level of 21 by volume 0220 _5S00ppm Water dew point 359C 31 F Lubricants droplets mist 0 5 mg m Water 25mg nmv z 20 XSTREAM TECHNICAL DATA Maximum Operational Certified to 200 m 656 ft depth Typical Work of Breathing 1 5 J l see diagrams below 50m on air 62 5 I min Typical Work of breathing 1 7 J l see diagrams b
18. lty may be increased by conditions such as cold water poor visibility hard work and increased depth Always try to exercise pru dent judgement when determining whether or not to dive Never dive when tired or in poor health Diving deeper than 50m 164 ft using gasses other than air is more demanding on the equipment Most equipment on the market is only approved for use within EN 250 limits Although Xstream Deep is certified to 200m 656 ft depth and Xstream Deco is for use with pure oxygen you must al ways make sure all of your equipment is suitable Do not use gas mixtures containing Helium for dry suit infla tion Helium has very low insulating properties and contri Tu XSTREA RENE USER MANUAL ENGLISH butes to a more rapid cooling of the body Preferably Argon shall be used but must never be inhaled Insulating or actively hea ting of the body surface has very little effect on the hypothermia described above OXYGEN SAFETY REGULATIONS Oxygen alert and oxygen handling recommendations in this manual applies to all parts and products intended for use with greater than 21 oxygen by volume All accessories and other SCUBA equipment connected to Xstream must be approved by the manufacturer for use with the same oxygen content which is used with the Xstream Cylinder valves must always be opened carefully and slowly to avoid pressure shocks Oxygen can cause serious medical effects or even death if used i
19. ncorrectly Use recognised tables for oxygen exposure Xstream Deco Deco EN 144 3 is approved for oxygen ser vice directly from the box i e it is cleaned to NASA Specifi cation 1 Cleaning test Level 100 particle contamination and NVR levels less than ASTM G63 Level C 50 mg m2 hydrocarbons Xstream Duration Duration EN 144 3 is approved for EAN 50 service i e it is cleaned to the same level as Xstream Deco Regulators and all other equipment for oxygen service must be identified as such Xstream Deco Deco EN 144 3 and Duration Duration EN 144 3 must never be used with contaminated gas Refere to Breathing gas section PRODUCT DESCRIPTIONS The Xstream regulator models have been developed based on experience gained from deep diving cave diving wreck diving and cold water diving The different types all share some common requirements on safety through functiona lity simplicity and performance XSTREAM 2 ND STAGE A number of features greatly improve safety and ease of use If debris has degraded the function of the exhalation check valve it can easily be reached and corrected by just twis ting off the diffuser It is the only part which needs to be disassembled and if it gets lost during the operation the regulator will continue to function but must only be used for immediate ascent In case of a malfunction in the 1st stage causing exces sive intermediate pressure the safety valve integrated in the
20. rity at maximum 300 bar supply pressure and a maximum gas temperature of 60 C The Poseidon Xstream Duration Duration EN 144 3 is approved for use with gaseous oxygen up to 50 purity at maximum 300 bar supply pressure and a maximum gas temperature of 60 C Using gaseous mixtures containing oxygen at high pressure always presents a certain level of risk for equipment failure due to combustion Greater concentration oxygen greater pressure greater temperature respectively represents fac tors that contributes to increase the mentioned risk Therefore Poseidon has taken every precaution using state of the art technology expertise industrial standards and knowledge to lower the risk as far as possible Both Xstream Deco and Xstream Duration are engineered for oxygen use assembled and cleaned in a clean room environment made up by materials chosen to expose lowest possible risk x fai lure effect product and are tested and approved for oxygen use It is strictly prohibited to use the Poseidon Xstream Deco Duration with oxygen ref definitions without being fully trained and certified in the use of oxygen by a recognised training agency Failure to have such training and certifica tion could lead to death or serious personal injury It is likewise absolutely essential that the end user strictly follows the mandatory guidelines given in the users manual for the Xstream models Regular maintenan ce servicing and cleaning
21. ssure is twice the absolute interstage pressure given the cylinder valve pressure drop is within EN 250 limits Taking into account the normal variations in interstage pressure and adding a safety margin the required minimum cylinder pressure during diving is 50 bar cylinder pressure from O msw to 100 msw 70 bar cylinder pressure from 101 msw to 200 msw It is a good practise to always plan your dive according to the 1 3 rule planning to use 2 3 of the cylinder capa city TROUBLESHOOTING Effect Examine Reason Action Safety valve is opening Immersed in water small bubbles are coming from the mouth piece ELE I XSTREAM Is it only when hose is pulled Is it spon taneously opening Do they stop after the regu lator is rinsed Check the cracking pressure see sec tion 6 2 The bubb les remain cracking pressure is correct If yes it is its normal function If yes it may be a ist stage error If yes the valve was probably jammed with salt crystals If the crack ing pressure is too low the valve is slightly ope ned The servo valve is se verely jam med by salt crystals Terminate dive and have the regulator serviced Make sure al ways to rinse the regulator after every dive using fresh water Have the re gulator cor rectly set by an authorised dealer Have the regulator cleaned by an authorised dealer The regula tor free flows
22. ticu larly cold conditions a long hose 2 15m 7 ft has the benefit of warming the gas by as much as 12 C 22 F under certain conditions Using a long hose requires some basic knowledge in its use and routing to take the full advantages Poseidon does not recommend the use of hose protectors on Poseidon IP hoses Hose protectors have been shown to mislead the user to neglect the necessary pre dive hose inspection Therefore Poseidon hoses are fitted with wear preventing end crimps which in addition can be inspected for the full engagement of the hose to the insert at any time through the inspection hole The hose end at the 2nd stage includes the safety valve As a visible indication of a fault the excessive gas will bleed to the ambient environment The hose is available in the following lengths as standard 2 15m 7ft 1 60m 5 3 ft 0 90m 3 ft 0 70m 2 3 ft HE ULTIMATE DIVE Seer 14 R XSTREAM USAGE MOUNTING THE HOSE First time mounting the hose of the length you have cho sen start with unscrewing the blind screw 5mm allen key where you want the 2nd stage Be careful not to contamine either the open port or the hose end Screw the hose in place using a 13mm box spanner Continue with attaching the 2nd stage Just screw the nut over the 2nd stage housing and secure it firmly by hand PRE DIVE The procedure described below only describes the manner in which the regulator is assembled and does
Download Pdf Manuals
Related Search
Related Contents
Lenco Cooltab-73 Remington S6280 hair stylers BaseTravel 401 / 801 Import LC Issuance User Manual HP DL160 G5 3TB SATA STORAGE SERVER (AJ675A) Network Storage Server Netgear 790S Installation Guide SA-WX900 Rangiersystem für Caravans 取扱説明書【基本操作】 PRT-B002JW-BZ PRT Assistance à l`identification d`une télécommande de portail radio à l Copyright © All rights reserved.