Home
LS-B100 - crt-topographie.fr
Contents
1. 4S TOPCON LASER SENSOR LS B100 Thank you for purchasing the TOPCON LS B100 For the best performance of the instruments please read these instructions carefully and keep them in a convenient location for future reference GENERAL HANDLING PRECAUTIONS Before starting work or operation be sure to check that the system is functioning properly Remove the batteries from the instrument when you will not be using it for long period When washing the instrument avoid spraying it with a high pressure stream of water from a water hose The inside of the instrument will be damaged by the water This instrument is designed based on the International Standard IPX 6 but it is not protected from a high pressure water stream or submergence Affection of the radio waves When using the instrument in the following place the strong radio wave may cause faulty operation e Near the instrument occurring strong radio waves e g Transceiver e Near the radio wave towers such as television or radio DISPLAY FOR SAFE USE In order to encourage the safe use of products and prevent any danger to the operator and others or damage to properties important warnings are put on the products and inserted in the instruction manuals We suggest that everyone understand the meaning of the following displays and icons before reading the Safety Cautions and text INSTRUCTION MANUAL Display Meaning Ignoring or disregard of this display may lead to death or s
2. RPORATION BEWING OFFICE Block No 9 Kangding Street Beijing Economic Technological Development Area Beijing China 100176 Phone 10 6780 2799 Fax 10 6780 2790 TOPCON CORPORATION DUBAI OFFICE P O Bax293705 Office C 25 row C 2 Dubai Airport Free Zone Dubai UAE Phone 971 4 2895900 Fax 971 4 2995901 TOPCON CORPORATION 31267 90021 75 1 Hasunuma cho itabashi ku Tokyo 174 8580 Japan 5E www topcon cojp
3. al advice EXCEPTIONS FROM RESPONSIBILITY 1 The user of this product is expected to follow all operating instructions and make periodic checks of the product s performance 2 The manufacturer or its representatives assumes no responsibility for results of a faulty or intentional usage or misuse including any direct indirect consequential damage and loss of profits 3 The manufacturer or its representatives assumes no responsibility for consequential dam age and loss of profits by any disaster an earthquake storms floods etc A fire accident or an act of a third party and or a usage any other usual conditions 4 The manufacturer or its representatives assumes no responsibility for any damage and loss of profits due to a change of data loss of data an interruption of business etc caused by using the product or an unusable product 5 The manufacturer or its representatives assumes no responsibility for any damage and loss of profits caused by usage except for explained in the user manual 6 The manufacturer or its representatives assumes no responsibility for damage caused by wrong movement or action due to connecting with other products Standard Set Composition 1 LS B100 Instrument 0 cc eee eeeeeeeeeteeeeeeeeeeeeaee 1pc 2 C size dry cells 3 Carrying case 4 Instruction Manual cccccceeeeeeeeeeeeeeeeeeeeeeeeeeeaee 1pc Nomenclature and Functions Indicator Batt
4. erious N WARNING injury Ignoring or disregard of this display may lead to personal injury or physical damage to the instrument N CAUTION Injury refers to hurt burn electric shock etc Physical damage refers to extensive damage to buildings or equipment and furni ture HANDLING PRECAUTIONS Guarding the instrument against shock When transporting the instrument provide some protection to minimize risk of shock Heavy shock may affect beam accuracy SAFETY CAUTIONS N WARNING e There is a risk of fire electric shock or physical harm if you attempt to disas semble or repair the instrument yourself This is only to be carried out by TOPCON or an authorized dealer only e Risk of fire or electric shock Do not use damaged power cable plug and socket e Risk of fire or electric shock Do not use a wet battery e May ignite explosively Never use an instrument near flammable gas liquid matter and do not use in a coal mine Battery can cause explosion or injury Do not dispose in fire or heat The short circuit of a battery can cause a fire Do not short circuit battery when storing it e Battery can cause explosion or injury Remove battery when using the connector for external power supply CAUTION Do not allow skin or clothing to come into contact with acid from the batteries if this does occur then wash off with copious amounts of water and seek medic
5. ery a LA Please refer to the back of the ag instruction manual for the indicator cover display patterns Battery cover MT Power switch knob N Pa Power ON Short push S Power OFF Long push etective precision Mode switch ______ onnector for external power supply Remove battery when connecting Detector Clamp knob Clamp Detector Pipes that can be installed onto the LS B100 are as described below Shape Cylindrical Dimension 45 to 51mm in diameter Please refer to the instruction manual for the machine or contact the machine manufacturer for instructions on install 45 to51mm ing the mast onto the machine by welding etc lt a Base Operation 1 Position a rotating laser and turn on the laser 2 Raise or lower the machine blade or arm to position the cutting edge or bucket at the desired grade elevation 3 Mount the LS B100 onto the mast near the path of the laser beam and turn on the LS B100 4 Keep the machine blade or arm motionless and raise or lower the LS B100 and adjust until ON GRADE position are flashing This is the ON GRADE position 5 Securely clamp the LS B100 in place The reference position has been set 6 While operating use the LED display to continually check grade moving the blade or cutting filling according to the direction of the LS B100 display Indicator Height alert warning of Precision mode rotatin
6. f functions may be inval idated Connector for external power supply Connecting the connector cable PC 18 sold separately to the connector for external power supply will enable the use of the LS B100 from an external power supply When the instrument is operated with the external power supply the power save and the auto cut off functions will be invalidated The LS B100 will turn on when connection is made to external power supply The power switch of the instrument will not function when an external power supply is used Specifications Flashes quickly Dead battery Replace the dry battery with new one Rotating laser battery warning display Rotating laser battery remaining warning LED A flash shows that the rotating laser power is low This function is not usable to the rotating laser which does not have the function to output alarm signal i N Detective range 175mm 6 8inches Detective angle 360 Mode1 3mm 0 009ft Mode2 6mm 0 019ft Mode3 15mm 0 049ft Mode4 30mm 0 098ft 633 to 785nm 800m 2625ft Using RL 100 18 28 C size dry cells 4pcs Battery pack BT 68Q sold separately DC 10V to 30V Approximately 100 hours Using alkaline manganese dry cells Approximately 50 hours Using Battery pack BT 68Q Detective precision Laser beam positions and display patterns Indicator LED Detective precision 3mm 0 009ft 6mm 0 019ft 15mm 0 04 9ft 30mm 0 098ft Detectab
7. g laser KA Mode1 It is possible to change the detective precision of the e J aeh a the height alert function otrotating P A instrument e y ae Mode2 Please select Mode 1 to 4 according to the objective of the eA A eai o a Mode3 operation a Signal Pressing the detective precision Mode switch will change x Mode4 the mode and the corresponding LED lamp will light up During battery remaining display shown below the lamp e will flash Flashes Power save function RP n O The instrument turns the power save mode after detecting no Battery remaining display O laser beam for more than approx five minutes O_O During the power save mode LED 1 yellow 1 red will flash N a The mode is canceled automatically when the instrument O Battery remaining display LED O O detects a laser beam again The mode can also be canceled O Battery remaining for the LS B100 will be displayed at 3 levels by pressing the power switch again Goes out OO O Battery is sufficient When Mode 1 is selected the lamp will O O light up UW ght up Flashes AT Flashes slowly Auto cut off function The power is low but sensor is still usable The power will be turned off automatically after detecting no laser beam for more than approx 60 minutes To turn on the laser sensor press the power switch again When turning the power on by pressing the power switch for more than 5 seconds the power save and the auto cut of
8. le laser wave length Laser detecting range diameter Internal battery External power supply Continuous operating time 20 C 68 F O00 O OO e ee O oO e Flashes more slowly 50mm 0 16ft 100mm 0 32ft width 87 5mm 0 28ft 175mm 0 57ft width When the laser beam is off to the top or to the bottom Operating temperature Water proof Dimensions W D H 20 C to 50 C 4 F to 122 F IP66 Based on the standard IEC60529 158x166x357 mm 6 2 x6 5 x14 0 With Mechanical Clamp Weight Without cells 2 0kg 4 4lbs Detective angle Detective precision and Laser detecting range may vary depending on rotat ing laser being used or atmospheric conditions Battery using time will vary depending on environmental conditions and operations done with EMC NOTICE In industrial locations or in proximity to industrial power installations this instrument might be affected by electromagnetic noise Under such conditions please test the instrument performance before use JSIMA Japan Surveying Instruments Manufacturers Association LS B100 TOPCON POSITIONING SYSTEMS INC 7400 National Drive Livermore CA 94551 U S A Phone 925 245 8300 Fax 925 245 8599 www topcon com TOPCON CALIFORNIA 3380 Industral Bivd Suite 105 West Sacramento CA 95691 U S A Phone 916 374 8575 Fax 916 374 8329 TOPCON EUROPE POSITIONING B V TOPCON GREAT BRITAIN LTD Topcon House Ken
9. net Side Bone Lane Newbury Berkshire RG14 SPX U K Phone 44 1635 551120 Fax 44 1695 551170 survey sales topcon co uk laser sales topcon co uk TOPCON SOUTH ASIA PTE LTD Bik 192 Pandan Loop 07 01 Pantech Industrial Complex Singapore 128981 Phone 62780222 Pax 62783540 wivw tancon com 2g Essebaan 11 2908 LJ Capelle a d IJssel The Netherlands Phone 010 458 5077 Fax 010 284 4941 www topconeurope com IRELAND OFFICE Unit 69 Western Parkway Business Center Lower Ballymount Road Dublin 12 Lreland Phone 01460 0021 Fax 01460 0129 TOPCON DEUTSCHLAND G m b H Giesserallee 31 47877 Willich GERMANY Phone 02154 885 100 Fax 02154 885 111 info topcon de www topcon de TOPCON S A R L 89 Rue de Paris 92585 Clichy Cedex France Phone 33 1 41069490 Fax 33 1 47390251 topcon topcon fr TOPCON SCANDINAVIA A B Neongatan 2 43151 M lndal SWEDEN Phone 031 7109200 Fax 031 7109249 TOPCON INSTRUMENTS THAILAND CO LTD 77 62 Sinn Sathom Tower 37th Fl Krungdhonburi Rd Klongtonsai Klongsarn Bangkok 10600 Thailand Phone 02 440 1152 7 Fax 02 440 1158 TOPCON INSTRUMENTS MALAYSIA SDN BHD Excella Business Park Block C Ground amp 1st Floor Jalan Ampang Putra Taman Ampang Hilir 55100 Kuala Lumpur MALAYSIA Phone 03 42701088 Fax 03 42704508 TOPCON KOREA CORPORATION 2F Yooseoung Bidg 1595 3 Seocho Dong Seocho gu Seoul 137 876 Korea Phone 82 2 2085 0821 Fax 82 2 2055 0319 www topcon ca kr TOPCON CO
Download Pdf Manuals
Related Search
Related Contents
Samsung Gear circle Uživatelská přiručka Protocole et procédures pour les allergies et Weider 831.159830 Home Gym User Manual Service Manual MCO-18AC MCO-18AC(UV) Cirago CBUDM1 headphone 第12回 - 日本原子力学会 Entrega de informe al CPCCS Orange - Journal Septembre 2014 Git - Manual de usuario Copyright © All rights reserved.