1. Enabie Apply Bridge Configuration EIE ES RSTP Mode You must first enable STP RSTP mode before configuring any related parameters Parameter settings required for both STP and RSTP are the same Note that 802 1d refers to STP mode while 802 1w refers to faster RSTP mode Bridge Configuration Priority 0 61440 RSTP uses bridge ID to determine the root bridge the bridge with the highest bridge ID becomes the root bridge The bridge ID is composed of bridge priority and bridge MAC address So that the bridge with the highest priority becomes the highest bridge ID If all of the bridge IDs have the same priority the bridge with the lowest MAC address will then become the root bridge Note The bridge priority value must be in multiples of 4096 A device with a lower number has a higher bridge priority Ex 4096 is higher than 32768 Max Age 6 40 Enter a value from 6 to 40 seconds here This value represents the time that a bridge will wait without receiving Spanning Tree Protocol configuration messages before attempting to reconfigure If JetNet 3706 JetNet 3706f is not the root bridge and if it has not received a hello message from the root bridge in the amount of time equal to the Max Age then JetNet 3706 JetNet 3706f will reconfigure itself as a root bridge Once two or more devices on the network are recognized as a root bridge the devices will renegotiate to set up a new spanning tree topology Hello Ti
2. Good and Tx Good or Rx Bad and Collision Note If you see an increase in Bad or Collision counts this may mean that your network cable is not connected correctly or the network performance of the port is poor Please check your network cable Network Interface Card connected to your device the network application or reallocate the network traffic 34 korenix Click on Clear Selected to reset the counts of the selected ports and on Clear All to reset the counts of all ports Click on Reload to refresh the counts Also Click on Bad Collision Mode to change counter mode to RxBad and TxCollisions mode and on Good Mode button to change counter mode to RxGood and TxGood mode Note If the mode is changed The statistics counter will be reset to O Port Statistics 4 100BASE Down Enable i y TES 100BASE Down Enable 3 100BASE Dow hr Enable 0 Exo 100BASE D owr Enable 0 E 100BASE D owr Enable BS 0 5E B 1 00BASE TH lip Enable 212 BE 230 Port Statistics Type Link State RxGood RxBac T Gnod Collision 1 00BASE Down Enable 0 0 1 0D0BASE Down Enable t 0 JOOBASE Down Enable v 0 S 0 100BASE Down Enable 0 0 JOOBASE Down Enable 0 0 100BASE TX Up Enable 0 D Clear All Good Mode 4 6 2 Ping Utility This page provides Ping Utility for users to ping remote devices and to check whether the device is alive or not Type the t
3. 3 Introduction OVOEVIG W osi aniosusoesnsiannaanenesecassianasanmsesaraneduiadsnstientsetenesanesviasaranrnaaien 1 Malor Fealuless siento Se Seu ges in deste a enge md des nS 2 mite RR 2 Hardware Installation Hardware IntrodidollOlsssess eee tst tee tte nce e au e e he t e t da 3 Wira M ero CN njo Pit a 5 VA ALA NIRE SI E DU ical TU 6 Wiring Fast Ethernet POMS i2 onte bd dead dare petere sides 6 Wiring Fast Ethernet Fiber Ports cccccccseeceseeceeeceeeseeseeeeeseeeseeeens 7 Connecting Powered Device PD harna NAAN 7 DIN Rall Mounting Installato Miescie araa N 8 Preparation for Management Preparation for Web Interface cccccecccseececeeeeseeeseeeeseeeeseueesaueesaees 9 Feature Configuration BASIC Se TING asn aaa 11 POM GOM i GU FAO 35 55 99 9 90 9 9 9050 0040293 ug cun Ead eee ass dead coreduas 22 POWE Over ENENG useen eE nee ete dme dE pedea dE 23 Network RegdulttdaliGy s sostenido oomen int dest und qen o Segen ges E desine 27 MATS GIO LIZ AUO MG E UTEL 32 Monitoring and DIagroslle i i ier tee dy orte ieee Sees Ey eve rovc 34 DEVICE FIOM Ir AIG ES I eae 36 Save TOF scia E EE TOT 36 USGI Ute ec X 36 Powering the Powered Device PD lassincation Mee6halisITis acce d peut tela tnus tp pei bait RE tee dit iUm 37 Power Forwarding Capability ccccccccseeecseeeeseeeeeeeeeseeeeseeeeseeeesees 37 Appendix Product SOCCIIICATONS eue uisesedeoete ved oo eee oleo dendo belen die net
4. 4 2 1 Port Configuration This section shows you how to enable disable port state or configure port auto negotiation speed duplex flow control rate limit control and port aggregation settings It also allows you to view port status and aggregation information The following commands are covered in this section 4 2 1 Port Control 4 2 2 Port Status Port Control Port Control commands allow you to enable disable port state or configure port auto negotiation speed duplex and flow control korenix JETA Your Industrial Computing amp Networking Partner pon Port Configuration ystem o 7 Basic Setting e 2 Port Configuration Power over Ethernet uilsfiegotisken ww Disable e we L Port Status 2 Enable v amp utoNegotiation Disable w Disable w 3 Port Control sal Ie amp 7 Network Redundancy E 3 Enable uteNegatiatian Disable v e 7 Traffic Prioritization Enable w AutaNegotiation Disable R4 jg z Monsorend Diag 8 Enable vw AutaNegotiation Disable hs Device Frant Panel 3 Enable w j AutaMegotiation w Disable E3 Logout Apply Select the port you want to configure and make changes to the port State column Enable or disable the state of this port Once you disable the port it stops te linking and forwarding traffic The default setting when you receive the device is Enable which means all the ports are working Speed Duplex
5. 4 5 3 DSCP Queue Mapping i Use an 8 4 2 1 weighted fair queuing scheme Use a strict priority scheme 4 5 1 QoS Setting COS Only COS Only OS Only COS Only COS Only COS Only 2 Queue Scheduling Use an 8 4 2 1 weighted fair queuing scheme This is also known as WRR Weight Round Robin JetNet will follow a 8 4 2 1 rate to process the packets in a queue from the highest priority to the lowest For example the EH 2 TT d TT J LDO i Apply korenix system will simultaneously process 8 packets with the highest priority in the queue 4 packets with middle priority 2 packets with low priority and 1 packet with the lowest priority Use a strict priority scheme Packets with the highest priority in the queue will always be processed first Port Setting The Priority column is to indicate the default port priority value for untagged or priority tagged frames When JetNet 3706 JetNet 3706f receives the frames it will assign the value to the priority You can enable 0 1 2 3 to the port The priority is directly mapping to queue id queue 3 is the highest priority queue Trust Mode This indicates Queue Mapping types for you to select CoS Only Port priority will only follow CoS Queue Mapping that you have assigned DSCP Only Port priority will only follow DSCP Queue Mapping that you have assigned CoS first Port priority will follow CoS Queue Mapping first and then DSCP Queue Mapping rule DSCP firs
6. Ethernet Fiber JetNet 3706f supports multi mode 2km JetNet 3706f m or single mode 30km JetNet 3706f s for variable link distances Make sure the fiber port on the end device is the same as your JetNet 3706f The following table is the fiber transceiver that JetNet 3706f is equipped with Fiber um Connecter Wavelength um TXPwr min TxPwr Max RxPwr Min RxPwr Max LinkBudg dBm Distance km JetNet Multi mode 2Km 5Km SC 1310 20dB 14dB 31dB B 11dB 3706f m 50 62 5 125 So tem zom sadem adem odam dBm Note ME cnoemode sc 1310nm 15dBm 8dBm 34dBm 8dBm 19dBm 30km 3706 s 8 10 125 Note The IEEE standard suggests that the available transmission distance is 2KM for 62 5 125um fiber optical cable in 1310nm wave length Actually the attenuation of multi mode 62 5 125um optical fiber cable is 1 5dBm KM and the maximum link distance can be up to 4 5km 2 6 Connecting Powered Device PD Ports 1 4 are equipped with PoE injectors that are in compliance with IEEE802 3af standards for 15 4w forwarding capability and 30w High power for IEEE802 3at pre standards JetNet 3 06 JetNet 3706f follows the IEEE802 3af Alternative B mode connector assignments The following table shows pin assignments for alternative A and B for the Power Sourcing Equipment PSE Alternative B PPE Negative Voor TX 8 Positive Voon Fixe Negative Voor TX 8 Positive oot Txa Posie Von Axe Negaivepon es 17240 es
7. PD can be classified by JetNet 3706 JetNet 3706f through the classification information that is provided by the PD The intent of PD classification is to provide information about the maximum power required by the PD during operation The following table is the PD classification table Class ID Dee 5 Range of Maximum Power used of PD I Optional 0 44 3 84w I5 Not Allowed Reserved for Future use High Power Class ID number 4 is reserved for the future standard IEEE802 3at If the class ID is 4 then JetNet 3706 JetNet 3706f will perform high power forwarding procedures 5 2 Power Forwarding Capability In IEEE802 3af Power over Ethernet standards it specifies a 15 4w power budget for a PD system However 15 4w is not enough for some applications that need more than 15 4w For this purpose JetNet 3706 JetNet 3706f will execute power budget control based on the PD classification It will deliver 120W power output when JetNet 3706 JetNet 3706f is attached to DC 55V power and class 4 PD The following table shows calculations for PoE power forwarding capabilities at different power input voltages korenix Power Input V PoE output V PoE Output 1 PoE Output Power W DC 24 DC 21 0 615A Max 13 53w Max DC 32 DC 29 0 615A Max 18 45w Max DC 48 DC 45 0 615A Max 28 29w Max DC 55 DC 52 0 615A Max 29 52w Max 38 korenix 6 Appendix 6 1 Product Specifications Standard Switch Technology
8. Pee Won Txa Pose veon Axa Negative Veo es Nemea es eme vet Pin assignment of PSE Make sure the twisted pair cable is bound with the standard RJ 45 pin especially pins 4 5 7 and 8 If the RJ 45 is bound with the wrong RJ 45 conductors JetNet 3706 JetNet 3706f will not recognize the PD and will forward DC 48V power to the PD since the switch follows the Alternative B mode In the IEEE 802 3af standard documents it indicates that the PD should support mode A and B and only receive power from either mode A or mode B korenix The following table shows the RJ 45 pin out for the PD 1 Poste port Negative vpon O O O O 2 Poste veon Negative oor 5 Necat veon Postvevpon C Positive pa Negave Vor Positive pa Negative Voon Negative oor Poste ven O 000 Nessive Vp Peaive Vp 0 ente por Poe por Notes Before installing the Powered Device PD please ensure that the PD pin assignment follows IEEE802 3af PD standards There are some IEEE802 3af pre standards stating that the PD can only accept mode A for power In the IEEE802 3af standaras it indicates that the PD could be powered by either Mode A or Mode B Caution The PoE port of JetNet 3706 3706f should not make connection to Ethernet network with outside plant routing includeing campus due the lighting strike may damage the system through the power system 2 DIN Rail Mounting Installation There are 2 DIN Rail Clips in each unit box Each set of D
9. System The following figure is the Web UI for System korenix JETA Your Industrial Computing amp Networking Partner pisci Welcome to the JetNet3706 e Industrial Managed Switch D Admin Password D IP Configuration D Time Setting D Backup and Restore D Firmware Upgrade D Factory Default Copyright c 2006 2007 Korenix Technology Ca Ltd All Rights Reserved D System Reboot amp CJ Part Configuration 9 7 Power over Ethernet amp 7 Network Redundancy 7 Traffic Prioritization 9 7 Monitor and Diag Figure 4 1 1 1 5 Device Front Panel 3 Save 3 Logout ptior Jethet3 706 Industrial Managed Switch v1 0 20070826 00 12 7 7 fE03 67 System Description View a description of the system JetNet 3706 JetNet 3706 f Industrial Management Ethernet Switch is the name of this product Firmware Version Display the firmware version installed on this device MAC Address Display the unique hardware address MAC address assigned by the manufacturer 4 1 2 Admin Password You can change the username and password to enhance security The following figure is the Web UI for Admin Password Username Key in a new username The default setting is admin Password Key in a new password The default setting is admin Confirm Password Re enter the new password to confirm it Once you finish configuring the settings click Apply to apply your configuration Note Always remember to select Sav
10. amp korenix Korenix JetNet 3706 JetNet 3706f Industrial Web Managed PoE Plus Switch User Manual Version 2 2 22 May 2008 korenix www korenix com korenix Korenix JetNet 3706 JetNet 3706f Series Industrial Web Managed PoE Plus Switch User Manual Copyright Notice Copyright 2007 Korenix Technology Co Ltd All rights reserved Reproduction in any form or by any means without permission is prohibited korenix Federal Communications Commission FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user s authority to operate this equipment 1 1 1 1 2 1 3 2 2 1 2 2 2 3 2 4 2 5 2 6 2 3 3 1 4 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 5 5 1 5 2 6 1 6 2 6
11. column Configure the port speed and duplex mode of this port Below are the selections you can choose Fast Ethernet Port 1 6 fa1 fa6 Auto Negotiation 10M Full Duplex 10 Full 10M Half Duplex 10 Half 100M Full Duplex 100 Full and 100M Half Duplex 100 Half The default mode is Auto Negotiation mode for fast Ethernet port 100M full for fiber port Flow Control column Enable or disable the flow control function Enable means that you need to activate the flow control function of the remote network device in order to let the flow control of that corresponding port on the switch to work Disable means that you do not need to activate the flow control function of the remote network device as the flow control of that corresponding port on the switch will work either way Once you have finished configuring the settings click Apply to save the configuration 22 korenix 4 2 2 4 3 4 3 1 Technical Tips If both ends are going at different speeds they will not link to each other If both ends are in different duplex modes they will be connected by half mode Port Status Port Status shows you the current port status Port Status 1 100BASE Down Enable E Disable 2 100BASE Down Enable Disable 3 100BASE Down Enable 2 Disable Ins TOOBASE Down Enable Disable 6 100BASE TX Up Enable 100 Full Disable bm TOOBASE Down Enable Disable A description of each column is as follows Por
12. one hour earlier than the actual time Jayllg 1t Saving Start s Once you have finished the configuration click Apply to apply your configuration 4 1 5 Backup and Restore With the Backup command you can save current configuration files saved in the switch s flash to the admin PC or TFTP server This will allow you to go to the Restore command later in order to restore the configuration file back to the switch Before you restore the configuration file you must place the backup configuration file into the PC or TFTP server The switch will then download this file back to the flash There are 2 modes for users to backup restore the configuration file Local File mode and TFTP Server mode Local File mode In this mode the switch acts as the file server Users can browse the target folder and then type in the file name to backup the configuration Users can also browse the target folder and select existing configuration files to restore the configuration back to the Switch TFTP Server mode In this mode the switch acts as TFTP client Before you do so make sure that your TFTP server is ready Then type in the IP address of the TFTP Server and backup configuration file name This mode can be used in both CLI and Web UI TFTP Server IP Address Key in the IP address of your TFTP Server here 16 korenix Backup Restore File Name the filename of the configuration file Configuration File The configuration file of the swi
13. primary and block the other path s It will also keep track of the blocked path s in case the primary path fails Soanning Tree Protocol STP introduced a standard method to accomplish this It is specified in IEEE 802 1D 1998 Later Rapid Spanning Tree Protocol RSTP was adopted and represents the evolution of STP providing for a much faster spanning tree convergence after a topology change This is specified in IEEE 802 1w In 2004 IEEE 802 1w was included into the IEEE 802 1D 2004 version This switch supports both RSTP and STP all switches that support RSTP are also backwards compatible with switches that support only STP This page allows you to enable disable RSTP and configure the global setting and port settings 27 korenix korenix JETA Your Industrial Computing amp Networking Partner su ethet 700 Rapid Spanning Tree Protocol DL System o 7 Basic Setting J Part Configuration RSTP Enable I 5 Part Control 4 Part Status EJ Power over Ethernet E PoE Control PoE Schedule 5 PoE Status EJ Network Redundancy a 4 RSTP Information D Multiple Super Ring rt Path Cost Priorit dmin T 5 Multiple Super Ring Inforn EN TET Auta e Traffic Prioritization 200000 e Monitor and Diag ML i28 v E Era 3 Device Front Panel 3 z00oo0 28 auta w Enabie 3 Save 4 200000 128 elato Enatie 5 Logout 5 200000 fize w amp uo gt Enabie 6 200000 1128 w uo
14. target file you want to backup restore Note The folders of the path to the target file do not allow you to input space key The following figure is the Web UI for Backup Restore Configuration TFTP Server mode Backup Configuration J 1 87 158 0 100 me backup conf Type in the IP address of TFTP Server IP Then click on Backup Restore Firmware Upgrade In this section you can update the switch with the latest firmware Korenix provides the latest firmware on Web site www korenix com New firmware may include new features bug fixes or other software changes The Web site also provides release notes for the update as well We suggest you use the latest firmware before installing the switch Note The system will automatically reboot after you finish upgrading the new firmware Please inform all attached users before doing this The following figure is the Web Main UI for Firmware Upgrade Firmware Upgrade System Firmware Version v1 0 System Firmware Date 20071002 15 38 14 Firmware Upgrade LocalFile Firmware File Name FTP etNet3 r b v1 D bin fl Mote When firmare upgrade is finished the switch will restart automatically Upgrade There are 2 modes for users to upgrade the firmware Local File mode and TFTP Server mode Local File mode In this mode the switch acts as the file server Users can browse the target folder and then type in the file name to upgrade the firmwa
15. the transmission of the firmware the system will copy the firmware file and replace the firmware in the flash 19 korenix 4 1 7 Factory Default In this section you can reset all the configurations of the switch to its default settings By clicking on Reset the system will reset all configurations to its default settings The system will show you a popup message window after running this command Default settings will be in effect after rebooting the switch korenix JETO Your Industrial Computing amp Networking Partner A Jetet3706f Reset to Default Cy System E Basic Setting D Admin Password Note The command will reset all configurations to the default settings except the IP address 5 IP Configuration Time Setting Reset 5 Backup and Restore 3 Firmware Upgrade 5 Factory Default 3 System Reboot eo 5 Port Configuration d 3 Power over Ethernet CJ Network Redundancy P CJ Traffic Prioritization amp EJ Monitor and Diag 3 Device Frant Panel 3 Save 3 Logout The Web UI figure for Reset to Default The following figure is the popup alert screen to confirm the command Click on Yes to reset the system Confirm Dialog The following Ul is a popup message screen to show you that the reset is complete Click OK to close the screen Then go to the Reboot page to reboot the switch Success Message Reset to Deafault OK Please reboot switch to run the default settings except th
16. to 31 If the name field is left blank the name of this ring will automatically named with RingID korenix Your Industrial Computing amp Networking Partner veel He Multiple Super Rin 5 gysten P P g o CJ Basic Setting o CJ Part Configuration New Ring o 7 Power over Ethernet EJ Network Redundancy 3 RSTP 4 RSTP Information D Muti Super Rina 5 Multiple Super Ring Inforn C Traffic Prioritization Ring Configuration e EJ Monitor and Diag D Device Front Panel L Mame Save 5 Logout Ring Status 128 Port 3 128 Port 4 128 Enable Z This page allows you to enable the settings for Multiple super ring 30 korenix Ring Configuration Ring Name Status Ring Rapid Super Ring 128 Port 5 128 Port B 128 Disable 2 4 4 4 Ring Configuration ID Once a Ring is created This appears and can not be changed Name This field will show the name of the Ring If it is not filled in when creating it will be automatically named by the rule RinglID Version The version of Ring can be changed here There are two modes to choose Rapid Super Ring as default and Super ring for compatible with Korenix 1 general ring Device Priority The switch with highest priority highest value will be automatically selected as Ring Master Then one of the ring ports in this switch will become forwarding port and the other one will become blocking port If all of the switches have the same priority t
17. Activity Green blinking Ring Master Green on Support Positive or negative power system with DC 24 55V power input range and polarity reverse protection 8 Watts 48V Maximum without PD loading DIN Rail mount or desktop IP 31 grade aluminum metal case 45 5 mm H x 185 3 mm W x 136 mm D without DIN JetNet 3706 0 70 kg with package 0 65 kg without package JetNet 3706f 0 68 kg with package 0 64 kg without package 3706 20C 60C 3706f 10C 60C 5 90 non condensing 40C 80 C 5 90 non condensing CE EN60950 FCC Class A CE EN55022 2003 class A CE EN55024 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS IEC60068 2 27 IEC60068 2 6 IEC60068 2 32 MIL HDBK 217F GB standard JetNet 3706 324 345 Hours JetNet 3706f 272 306 Hours 5 Years 40 korenix 6 2 Revision History Edition VO 1 V1 0 V2 0 V2 1 V2 2 Date 23 May 2007 10 Oct 2007 04 Dec 2007 14 Apr 2008 22 May 2008 Modifications The first version 2 version 3 version modified for RSR and PoE powering mode 1 modified for MSR change COS priority of QOS from 077 to 0 3 2 UL certification and modify Modify some of power input description and drop relay alarm information 4 korenix 6 3 About Korenix Less Time At Work Fewer Budget on applications The Korenix business idea is to let you spend less time at work and fewer budget on your applications Do you really w
18. Disabled Root Forwarding 200000 128 P2P Non Edge Disabled 200000 128 P2P Edge Disabled 200000 128 P2P Edge J Disabled 200000 128 P2P Edge E Disabled 2000000 128 P2P Edge Reload 29 korenix 4 4 2 RSTP Info This page allows you to see the information of the root switch and port status Root Information You can see Root Bridge ID Root Priority Root Port Root Path Cost and the Max Age Hello Time and Forward Delay of BPDU sent from the root switch Port Information You can see port Role Port State Path Cost Port Priority Oper P2P mode and Oper edge port mode 4 4 3 Multiple super ring MSR The most common industrial network redundancy is to form a ring or loop Typically the managed switches are connected in a series and the last switch is connected back to the first one In such a connection you can use Korenix Multiple super ring technology Super Ring is Korenix s 1 generation ring redundancy technology released with JetNet 4000 4500 Rapid Super Ring RSR is Korenix s 2 generation Ring redundancy technology The Rapid Super Ring has an enhanced Ring Master selection and shorter recovery time Mutilple Super Ring is the 3 Korenix Ring technology It is designed for more complex ring application and even more faster recovery time These are patented and protected by Korenix and is used in countries all over the world New Ring To create a Multiple super ring Just fill in the Ring ID which have a range from 0
19. IN Rail clips include 4 screws and 2 clips If the DIN Rail set is missing please contact a Korenix distributor for help Use the screws to attach the DIN Rail clip to the wall mount plate included Wall Mount Installation Follow the steps below to install JetNet 3706 JetNet 3706f with its included wall mount plate Use the hook holes at the corners of the wall mount plate to hang JetNet 3706 JetNet 3706f on the wall Wall Mount plate and screws korenix 3 Preparation for Management 3 1 3 1 1 The Korenix JetNet 3706 JetNet 3706f provides Web browser configure interface You just need to know the device s IP address and you can remotely connect to its embedded HTTP web pages The following topic are covered in this chapter 3 1 Preparation for Web Interface Preparation for Web Interface The JetNet 3706 JetNet 3706f provides HTTP Web Interface for web management Web Interface The Korenix web management page uses JavaApplet This allows you to use a standard Web browser such as Microsoft Internet Explorer or Mozilla FireFox to configure the switch from anywhere while connected to the network Before you attempt to use the embedded web interface to manage switch operation verify that your JetNet 3706 JetNet 3706f Industrial Ethernet Switch is properly installed on your network and that every PC on the network can access the switch via Web browser 1
20. Setting Time Setting source allow user to set the time by manually or through NTP server It also provide time synchronize from PC Network Time Protocol NTP is used to synchronize computer clocks on the internet You can configure NTP settings here to synchronize the clocks of several switches on the network JetNet 3706 JetNet 3706f also provide Daylight Saving function 13 korenix korenix JETA l 7 JetNet3706 ime Setting a md D IP Configuration Your Industrial Computing amp Networking Partner System Basic Setting D nimi eaer System Time Sun Jan 1 00 16 38 2006 Time Setting L e Setting arce Manual Setting D Backup and Restore i Firmware Upgrade D Factory Default CJ Port Configuration 2 Power over Ethernet o 7 Network Redundancy o 7 Traffic Prioritization o 7 Monitor and Diag 5 Device Front Panel 5 Save G Logout Aae Pri pes ee Ie Boer T gt 5 System Reboot Manual Setting User can select Manual setting to change time as user want and also click the icon Get Time From PC to sync time from your PC NTP client Select the Time Setting Source to NTP client can let device enable the NTP client It allow JetNet 3706 JetNet3706f get time from 2 different NTP servers The system will send request packet to acquire current time from the NTP server MTP Client Manual Setting NTP Client 14 kor
21. Super Ring and Legacy Super Ring Client modes Multiple Super Ring MSR technology is Korenix s gm generation Ring redundancy technology This is patented and protected by Korenix and is used in countries all over the world MSR ranks the fastest recovery time both failover and restore time in the world less than 5 milliseconds in 10 100 Megabit Copper Ring topology To backward compatible with the Legacy Super Ring technology implemented in JetNet 4000 4500 switches JetNet 3706 JetNet 3706f also supports Super Ring Client mode The Super Ring ports can pass through Super Ring control packets extremely well and works with Super Ring Besides Korenix ring technology JetNet 3706 JetNet3706f also supports IEEE 802 1D 2004 version Rapid Spanning Tree Protocol RSTP The new version of RSTP standard includes IEEE 802 1D 1998 STP 802 1w RSTP The following commands are included in this section 4 4 1 RSTP 4 4 2 RSTP Info 4 4 3 Multiple Super Ring 4 4 4 Ring Info RSTP RSTP stands for Rapid Spanning Tree Protocol If a switch has more than one path to a destination it will lead to message loops that can generate broadcast storms and quickly bog down a network The spanning tree was created to combat the negative effects of message loops in switched networks A spanning tree uses a spanning tree algorithm STA to automatically sense whether a switch has more than one way to communicate with a node It will then select the best path
22. System Throughput MAC Address Packet Buffer Transfer performance Management interface Class of Service Quality of Service DHCP Timer Network Redundancy Firmware upgrade PoE Port Control Power Limit Control PoE Scheduling Control LPLD function Number of Ports Connectors PoE Technology IEEE 802 3 10Base T IEEE 802 3u 100Base T IEEE 802 1p Class of Service IEEE 802 3af Power Over Ethernet IEEE 802 1d Spanning Tree IEEE 802 1w Rapid Spanning Tree Store and Forward Technology with 3 2Gbps wire speed non blocking Switch Fabric 1 785Mpps 2000 Embedded 1Mbits shared buffer 14 880pps for Ethernet and 148 800 for Fast Ethernet and transfer packet size from 64 to 1522Bytes Embedded HTTP Server for Web Management and JetView IEEE802 1p class of service 4 priority queues per port Quality of Service determined by port Tag and IPv4 Type of Service Supports DHCP Client Supports Network Time Protocol NTP to synchronize time from internet Supports Multiple super ring function for network redundancy with 5 30 ms network recovery time To inter operate with other higher level switches JetNet3706 JetNet3706f also compliant with IEEE802 1d 2004 edition for RSTP and STP TFTP HTTP and JetView firmware upgrade Supports user configure for PoE enable disable The control mode supports IEEE802 3af standard Manual and Ultra mode for 30W Hi power The maximum deliver power on each PoE port is 12 915W DC 24V i
23. Verify that your network interface card NIC is operational and that your operating system supports TCP IP protocol 2 Wire the DC power to the switch and connect your switch to your computer 3 Make sure that the switch default IP address is 192 168 10 1 4 Change your computer IP address to 192 168 10 2 or another IP address in the 192 168 10 x subnet Network Mask 255 255 255 0 5 Switch to DOS command mode and ping 192 168 10 1 to verify a normal response time 6 Launch a web browser Internet Explorer or Mozilla FireFox on your PC Type http 192 168 10 1 or the IP address of the switch into the Web address window Press Enter 8 Keyin the username and Koremix Switch Manager password The default username and password are i Please enter user name and password admin Site 192 168 10 1 User Name admin 9 Click OK The welcome page of the web based management interface will now appear korenix korenix JETA Your Industrial Computing amp Networking Partner mt Welcome to the JetNet3706 m i C Basic Setting Industrial Managed Switch o 7 Port Configuration gt EI Power over Ethernet System Description JetNet3706 Industrial Managed Switch o J Network Redundancy v0 20070907 EJ Traffic Prioritization Firmware Version o EJ Monitor and Diag 00 12 77 1 03 67 Save Copyright c 2006 2007 Korenix Technology Co Ltd All Rights Reserved Logout 10 Once you enter the web
24. ant to go through all the troubles but still end up with low quality products and lousy services Definitely not This is why you need Korenix Korenix offers complete product selection that fulfills all your needs for applications We provide easier faster tailor made services and more reliable solutions In Korenix there is no need to compromise Korenix takes care of everything for you Fusion of Outstandings You can end your searching here Korenix Technology is your one stop supply center for industrial communications and networking products Korenix Technology is established by a group of professionals with more than 10 year experience in the arenas of industrial control data communications and industrial networking applications Korenix Technology is well positioned to fulfill your needs and demands by providing a great variety of tailor made products and services Korenix s industrial grade products also come with quality services No more searching and no more worries Korenix Technology stands by you all the way through Core Strength Competitive Price and Quality With our work experience and in depth know how of industrial communications and networking Korenix Technology is able to combine Asia s research development ability with competitive production cost and with quality service and support Global Sales Strategy Korenix s global sales strategy focuses on establishing and developing trustworthy relationships with value a
25. arget IP address of the target device into Target IP Click on Start to start the ping After few seconds you will see the results in the Result field Ping Utility Ping TametP i 92 168 10 200 start Result PING 192 166 710 200 192 158 10 200 56 data bytes 54 bytes from 1932 158 10 200 icmp_seg 0 ttlz128 time 0 0 ms B4 bytes from 192 168 170 200 icmp seqz1 ttlz128 time 0 0 ms 64 bytes from 132 158 10 200 icmp _seq 2 ttlz128 time 0 0 ms 54 bytes from 1932 158 10 200 iemp seq 3 ttlz128 time 0 0 ms B4 bytes from 192 158 10 200 iemp seqe 4 ttlz128 time 0 0 ms 182 158 10 200 ping statistics 5 packets transmitted 5 packets received 0 packetloss round trip min avgimax D O0 0 0 0 0 ms 35 korenix 4 7 Device Front Panel Device Front Panel provides Web type LED panel which indicates status of power PoE powering and link status of Ethernet Eq JetNet3706 5 System o 7 Basic Setting o Port Configuration i Power a Ethernet korenix o L7 Network Redundancy o 7 Traffic Prioritization Er NET AY F Manitor and Diag industrial Managed PoE Switch 5 Device Front Panel 5 Save 5 Logout Device Front Panel 4 8 Save to Flash Save Configuration allows you to save any configuration you just made to the Flash Powering off the switch without clicking on Save Configuration will cause loss of new settings After selecting Save Configuration click on Save to Flash to save your new confi
26. based management interface you can change the JetNet 3706 JetNet 3706fs P address to fit your network environment Note 1 Internet Explorer Version 5 0 or later does not allow Java applets to open sockets by default Users must directly modify the browser settings to selectively enable Java applets in order to use network ports Note 2 he Web Ul connection session of JetNet 3706 JetNet 3706f will logout automatically if you do not input anything after 30 seconds Re login if this occurs 10 korenix 4 Feature Configuration This chapter explains how to configure the JetNet 3706 JetNet 3706f software and its features The following topics are covered in this chapter 4 1 Basic Settings 4 2 Port Configuration 4 3 Power over Ethernet 4 4 Network Redundancy 4 5 Traffic Prioritization 4 6 Monitor and Diag 4 7 Device Front Panel 4 8 Save to Flash 4 9 Logout 4 1 Basic Settings This section provides you with instructions on how to configure switch information set the IP address and configure the username and password of the system It also allows you to upgrade the firmware backup and restore a configuration reload the system to factory default and reboot the system The following is included in this section 4 1 1 Switch Setting 4 1 2 Admin Password 4 1 3 IP Configuration 4 1 4 Time Setting 4 1 5 Backup and Restore 4 1 6 Firmware Upgrade 4 1 7 Factory Default 4 1 8 System Reboot l1 korenix 4 1 4
27. ch fabric of the JetNet 3706 JetNet 3706f supports 4 physical queues lowest low middle and high users should assign a DSCP value to the level of the physical queue With the JetNet 3706 JetNet 3706f users can easily change the mapping table to follow the upper layer 3 switch or routers DSCP setting Traffic Prioritization DSCP Queue Mapping DSCFP 0 wn 4 iaueue DSCP B ce 2 r2 HE R E HORE d Gueue T DSCF c pr Je spe e e pn e e aln Je spe e pn e e 4 al r2 AOR SAGA OR OR e al 2 bh 2 ER Queue l DSCP 24 r3 AOR E e e RE e 2 2 2 3 1 iaueue re ADR SR ROKR SAGAS Eon em CA Eod E E B _ EE AOR kedek 5 ERI e s Mote Gueue 3 is the highest priority queue i Apply After configuring press Apply to enable the settings Monitoring and Diagnostic JetNet 3706 JetNet 3706f provides port statistics function for you to monitor the status of the switch or create a diagnostic for you to check the problem when issues with the switch occur The following commands are included in this section 4 6 1 Port Statistics 4 6 2 Ping Port Statistics On this page you can view operational statistics for each port The statistics that can be viewed include Link Type Link State Rx Good Rx Bad Tx Good and Collision Rx means the received packets while Tx means the transmitted packets The statistics can just show Rx
28. cides which port should be blocked by priority in a LAN Admin P2P Some of the rapid state transitions that are possible within RSTP depend upon whether the port of concern can only be connected to another bridge i e it is served by a point to point LAN segment or if it can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows P2P status of the link to be manipulated administratively Auto means to auto select P2P or Share mode P2P means P2P is enabled while Share means P2P is disabled Admin Edge A port directly connected to the end stations cannot create a bridging loop in the network To configure this port as an edge port set the port to the Enable state When the non bridge device connects an admin edge port this port will be in blocking state and turn to forwarding state in 4 seconds Once you have finished your configuration click Apply to save your settings korenix Your Industrial Computing amp Networking Partner SS ia RSTP Information 3 System o CI Basic Setting i e C3 Port Configuration Root Information o C Power over Ethernet 9 C Network Redundancy 3 RSTP 5 RSTP Information Multiple Super Ring 3 Multiple Super Ring Inforn o CI Traffic Prioritization o C Monitor and Diag 3 Device Front Panel 3 Save a Logout 8000 0012 7700 0112 32768 2 600000 20 sec 2 sec 15 sec Path Cost 200000 128 P2P Edge E
29. dded distributors and channel partners and assisting OEM distributors to promote their own brands Korenix supplies products to match local market requirements of design quality sales marketing and customer services allowing Korenix and distributors to create and enjoy profits together Quality Services KoreCARE KoreCARE is Korenix Technology s global service center where our professional staffs are ready to solve your problems at any time and in real time All of Korenix s products have passed ISO 9000 EMI CE FCC UL certifications fully satisfying your demands for product quality under critical industrial environments Korenix global service center s e mail is koreCARE korenix com 5 Years Warranty Each of Korenix s product line is designed produced and tested with high industrial standard Korenix warrants that the Product s shall be free from defects in materials and workmanship for a period of five 5 years from the date of delivery provided that the Product was properly installed and used This warranty is voided if defects malfunctions or failures of the warranted Product are caused by damage resulting from force measure such as floods fire etc environmental and atmospheric disturbances other external forces such as power line disturbances host computer malfunction plugging the board in under power or incorrect cabling or the warranted Product is misused abused or operated altered and repaired in an unauthorized or
30. e IP address 20 korenix Click OK The system will then automatically reboot the device Note If you have already configured the IP of your device to another IP address when you use this command through CLI and Web Ul our software will not reset the IP address to the default IP The system will maintain the IP address so that you can still connect to the switch via the network 4 1 8 System Reboot system Reboot allows you to reboot the device Some of the feature changes require you to reboot the system Click on Reboot to reboot your device Note Remember to click on the Save button to save your settings Otherwise the settings you made will be gone once the switch is powered off Below is the Main screen for Reboot korenix Your Industrial Computing amp Networking Partner G JetNet3706 Reboot 5 system e 7 Basic Setting 3 Admin Password Please click Reboot buttan to restart switch device 3 IP Configuration 5 Time Setting 5 Backup and Restore 5 Firmware Upgrade 5 Factory Default 1 System Reboot 7 Port Configuration 5 Port Contral 4 Part Status Below is the popup alert screen to request confirmation for the Switch Reboot Click on Yes to reboot the switch Confirm Dialog 2 Do you want to really reboot switch The popup message screen below appears when rebooting the switch success Message a Switch rebooting Auto relogin after 30 seconds 21 korenix 4 2
31. e etie gente 39 FROWIS OMI STONY E OLD 41 PAD OUT IN ONC IIX cerana aa a bacene st 42 korenix 1 1 Introduction Thank you for purchasing the JetNet 3706 JetNet 3706f and welcome to the Korenix JetNet 3706 JetNet 3706f Series Industrial Web Managed Power over Ethernet PoE Switch User Manual The following topics are covered in this chapter 1 1 Overview 1 2 Product Features 1 3 Package Checklist Overview JetNet 3706 and JetNet 3706f are Industrial Web Managed Power over Ethernet PoE owitches which include 4 Fast Ethernet RJ 45 ports with PoE injectors 2 additional RJ 45 ports for JetNet 3706 and 2 additional Fast Ethernet fiber ports for JetNet 3706f The additional ports can connect with a High End Switch or a PC workstation JetNet 3706 JetNet 3706f complies with IEEE802 3af PoE standards and IEEE802 3at pre standards The maximum power forwarding ability ranges from 13 53w to 29 52w based on the voltage of the power input JetNet 3706 JetNet 3706f provides simple management interface via Web browser to feature more network performances Network Redundancy To obtain superior network forwarding performance JetNet 3706 JetNet 3706f adopts QoS mechanism Multiple Super Ring and RSTP which is in complies with IEEE802 1w 2004 edition to deliver a non stop forwarding network High Power PoE The excellent PoE power management features IEEE 802 3af auto mode IEEE 802 3af manual mode Ultra power mode for 30W high pow
32. e to save your settings Otherwise the settings you made will be lost when the switch is powered off Admin Password 12 korenix The following figure is the popup alert window when the incorrect username is entered Error Message YTY Connect and Login Failed gt admin 4 1 3 IP Configuration This function allows user to configure the switch s IP address settings IP Configuration DHCP Client Disable 1 372 158 10 1 255 255 255 0 1 92 168 10 254 DHCP Client Enable or Disable DHCP Client function When DHCP Client function is enabled an IP address will be assigned to the switch from the network s DHCP server In this mode the default IP address will be replaced by the one assigned by the DHCP server If DHCP Client is disabled then the IP address that you specified will be used instead IP Address You can assign the IP address reserved by your network for your JetNet 3706 JetNet 3706f t DHCP Client function is enabled you don t need to assign an IP address as it will be overwritten by the DHCP server The default IP address is 192 168 10 1 Subnet Mask Assign the subnet mask for the IP address If DHCP Client function is enabled you don t need to assign the subnet mask The default Subnet Mask is 255 255 255 0 Gateway Assign the gateway for the switch The default gateway is 192 168 10 254 Once you finish configuring the settings click Apply to apply your configuration 4 1 4 Time
33. ed its Role from nonRM to RM or from RM to nonRM Role state Transition Count This number means how many times the Ring status has been transformed between Normal and Abnormal state korenix JETA ss Fes Multiple Super Ring Information B System o 7 Basic Setting x EI Port Configuration ID Version Role Status RM MAC Ping pral o CJ Power over Ethernet 1 o 7 Network Redundancy 1 Rapid Super Ring EM Abnormal 0012 7 7ff 0370 2 3 4 RSTP 4 RSTP Information D Multiple Super Ring ry Multiple Super Ring Infarn o 7 Traffic Prioritization o CI Monitor and Diag Device Front Panel 5 cave Di Logout Your Industrial Computing amp Networking Partner MESS m ans 4 5 Traffic Prioritization Quality of Service QoS provides a traffic prioritization mechanism that allows users to deliver better service to certain flows QoS can also help to alleviate congestion problems and ensure that high priority traffic is delivered first This section allows you to configure Traffic Prioritization settings for each port in regards to setting priorities The JetNet 3706 JetNet 3706f QoS supports 4 physical queues weighted fair queuing WRR and Strict Priority scheme which follows 802 1p COS tag and IPv4 DSCP information to prioritize the traffic of your industrial network The following commands are explained in this section QoS Setting 4 5 1 QoS Setting Queue Scheduling 4 5 2 CoS Queue Mapping
34. enix Time zone Select the time zone where the switch is located For your reference the following table lists the time zones of different locations The default time zone is GMT Greenwich Mean Time Switch config clock timezone GMT 12 00 Eniwetok Kwajalein GMT 11 00 Midway Island Samoa GMT 10 00 Hawaii GMT 09 00 Alaska GMT 08 00 Pacific Time US amp Canada Tijuana GMT 07 00 Arizona GMT 07 00 Mountain Time US amp Canada GMT 06 00 Central America GMT 06 00 Central Time US amp Canada GMT 06 00 Mexico City GMT 06 00 Saskatchewan GMT 05 00 Bogota Lima Quito GMT 05 00 Eastern Time US amp Canada GMT 05 00 Indiana East GMT 04 00 Atlantic Time Canada GMT 04 00 Caracas La Paz GMT 04 00 Santiago GMT 03 00 NewFoundland GMT 03 00 Brasilia GMT 03 00 Buenos Aires Georgetown GMT 03 00 Greenland GMT 02 00 Mid Atlantic GMT 01 00 Azores GMT 01 00 Cape Verde Is GMT Casablanca Monrovia GMT Greenwich Mean Time Dublin Edinburgh Lisbon London el el eel eee ee el ee ee el CS GMT 01 00 Amsterdam Berlin Bern Rome Stockholm Vienna GMT 01 00 Belgrade Bratislava Budapest Ljubljana Prague GMT 01 00 Brussels Copenhagen Madrid Paris GMT 01 00 Sarajevo Skopje Sofija Vilnius Warsaw Zagreb GMT 01 00 West Cen
35. er device and PoE scheduling control can enlarge your application and help saving power and more economic The JetNet 3706 JetNet3706f can apply with several of applications such as PoE IP camera with PTZ function Industrial I O device with PoE enabled High Power Forwarding Ability According to IEEE802 3af Power over Ethernet standards it specifies a 15 4w power budget for PD systems But for some applications 15 4w is not enough For this purpose JetNet 3 06 JetNet 3706f provides 2 models of PoE powering mechanisms IEEE802 3af and High power pre standard IEEE802 3at for high power budget To recognize the PD classification ID JetNet 3706 JetNet 3706f is equipped with a powerful micro processor for detection classification powering and disconnecting purposes JetNet 3706 JetNet 3706f automatically powers the PD with a different PD classification ID It can deliver a maximum of 80W 45 C output with a DC 55V power input for ID number 4 For the IEEE802 3af standard PD JetNet 3706 JetNet 3706f also supports a maximum of 61 4W power forwarding ability with DC 48V power korenix DC24V 48V PoE System For use with a DC 24V power source system JetNet 3706 JetNet 3706f is equipped with a dual mode PoE powering mechanism which detects power voltage input in order to execute the most beneficial powering and disconnecting process This feature is suitable for transportation systems or any applications without a DC 48V power source Also Je
36. guration EI JetNet3706 Save to Flash 5 System Fj Basic Setting amp C Port Configuration Mote This command will permanently save the current configuration to flash 7 Power over Ethernet e EJ Network Redundancy o 7 Traffic Prioritization e Monitor and Diag 5 Device Front Panel 3 Save 5 Logout 4 9 Logout The switch provides 2 logout methods Your web connection will log out if you do not input a command for 30 seconds The Logout command allows you to manually log out the web connection Click on Yes to logout and No to go back to the configuration page EI JetNet3706 Save to Flash 3 System e 7 Basic Setting 7 Part Configuration Note This command will permanently save the current canfiguratian to flash e 7 Power over Ethernet e 7 Network Redundancy ae e 7 Traffic Prioritization Monitor and Diag Confirm Dialog 3 Device Front Panel 5 Save Do you want to really logout 5 Logout CIS Java Applet Window 36 korenix 5 Powering the Powered Device PD This chapter describes powering classification scheme and power forwarding capabilities of JetNet 3706 JetNet 3706f The following are the topics for this chapter 5 1 Classification Mechanism 5 2 Power Forwarding Capability 5 1 Classification Mechanism JetNet 3706 JetNet 3706f is compliant with IEEE802 3af Power over Ethernet standards and IEEE802 3at pre standards for 30w power forwarding capability A
37. he switch with the biggest MAC address will be selected as Ring Master Ring Port1 In Rapid Super Ring environment you should have 2 Ring Ports No matter this switch is Ring Master or not when configuring RSR 2 ports should be selected to be Ring Ports For Ring Master one of the ring ports will become the forwarding port and the other one will become the blocking port Path Cost Change the Path Cost of Ring Port1 If this switch is the Ring Master of a Ring then it determines the blocking port The Port with higher Path Cost in the two ring Port will become the blocking port If the Path Cost is the same the port with larger port number will become the blocking port Ring Port2 Assign another port for ring connection Path Cost Change the Path Cost of Ring Port2 Ring status To enable disable the Ring Please remember to enable the ring after you add it Ring Information This page shows MSR information ID Ring ID Version which version of this ring this field could be Multiple super ring or Super Ring Role This Switch is RM or nonRM Status If this field is Normal which means the redundancy is approved If any one of the link in this Ring is broken then the status will be Abnormal 3l korenix RM MAC The MAC address of Ring Master of this Ring It helps to find the redundant path Blocking Port This field shows which port of RM is blocked Role Transition Count This means how many times this switch has chang
38. improper way Korenix Technologies Co Ltd 10F No 100 1 Ming Chuan Rd Shing Tien City Taipei Taiwan Tel 886 2 82193000 Fax 886 2 82193300 Business service sales korenix com Customer service koreCARE korenix com 42
39. lowing figure PoE LNK ACT papel korenix AE M M Ea zi KIKI TE Fl Fi Br NE TAY Industrial Web Managed PoE Switch JetNet 3706 Mylar layout PoE LNK ACT LLL korenix 2B Ee e ME zd El E RM i Blar NE T Industrial Web Managed PoE Switch JetNet 3706f Mylar layout Port Layout JetNet 3706 includes 4 Port 10 100TX that include embedded 4 Port PoE injection function in ports 1 4 and 2 additional RJ 45 for JetNet 3706 fiber for JetNet 3706f for uplink functionality See the following figures JetNet 3706f korenix Side View The right side view of the JetNet 3706 JetNet 3706f Industrial PoE Plus Switch consists of one 6 pin terminal block connector and one chassis earth ground screw The terminal block is for redundant power connections Protective Earth Ground 2 2 Wiring Power Inputs Follow the steps below to wire the redundant power of JetNet 3706 JetNet 3706f Not Used 1 Insert positive and negative wires into V and V contacts respectively in the terminal block connector Tighten the wire clamp screws to prevent DC wires from becoming loose Power 1 and Power 2 support power redundancy and polarity reverse protection functions The power input ranges from DC 24 55V Positive and negative power system inputs are both accepted but Power 1 and Power 2 must apply the same mode Note Please be sure to turn off input and load power and to unplug the power termi
40. me 1 10 Enter a value from 1 to 10 seconds here This is a periodic timer that drives the switch to send out a BPDU Bridge Protocol Data Unit packet to check current STP status The root bridge of the spanning tree topology periodically sends out a hello message to other devices on the network to check if the topology is healthy The hello time is the amount of time the root has waited in between sending hello messages 28 korenix Forward Delay Time 4 30 Enter a value between 4 and 30 seconds This value is the time that a port waits before changing from Spanning Tree Protocol learning and listening states to forwarding state This is the amount of time JetNet 3706 JetNet 3706f will wait before checking to see if it should be changed to a different state Once you have completed your configuration click on Apply to apply your settings Note You must observe the following rules to configure Hello Time Forwarding Delay and Max Age parameters 2 x Forward Delay Time 1 sec gt Max Age Time gt 2 x Hello Time value 1 sec Port Configuration Select the port you want to configure you will be able to view the current settings and status of the port Path Cost Enter a number between 1 and 200 000 000 This value represents the cost of the path to the other bridge from the transmitting bridge at the specified port Priority Enter a value between 0 and 240 using multiples of 16 This is the value that de
41. nal block before making wire connections Otherwise your screwdriver can inadvertently short your terminal connections to the grounded enclosure Note Suitable electric wire ranges from 12 to 24 AWG Note If the 2 power inputs are connected JetNet 3706 JetNet 3706f will be powered from the highest connected voltage korenix 2 3 Wiring Earth Ground To make sure data transmission is working properly the Chassis Ground must be connected to the protective earth Note All line to ground transient protection circuitry will be disabled if chassis ground is not connected with the protective earth To ensure the system will not be damaged by noise or any electrical shock we suggest making a direct connection with JetNet 3706 JetNet 3706f and Earth Ground to avoid system damage from electrical static discharge On the right side of JetNet 3706 JetNet 3706f there is one earth ground screw Loosen the earth ground screw with a screwdriver and tighten the screw after the earth ground wire is connected 2 4 Wiring Fast Ethernet Ports JetNet 3706 JetNet 3706f is equipped 4 Power over Ethernet PoE injectors with 30w forwarding capability in ports 1 4 The fast Ethernet ports support 10Base T and 100Base TX full or half duplex modes All of the fast Ethernet ports auto detect signals from connected devices to negotiate link speed and duplex mode Auto MDI MDIX allows users to connect to another switch hub or workstation without changing st
42. nput 30W DC50V input with 0 615A current Each PoE port would active and powering with different control rule and supports Weekly Scheduling by Hourly basis The Link Partner Line Detect function LPLD is available on PoE ports With the LPLD function the PoE port can keep attached PD alive 4 x 10 100Base TX with PoE Injector 3706 2 x 10 100Base TX ports 3 06f 2 x 100Base FX 10 100TX RJ 45 6 pin Terminal Block 2 Redundant power End Span wiring architecture PD classification detection class ID 0 3 for IEEE802 3af standard and 39 korenix Cable Diagnostic LED System Power Power Consumption Mechanical Installation Case Dimension Weight Operating Temperature Operating Humidity Storage Temperature Storage Humidity Safety EMI EMS Shock Vibration Free Fall MTBF Warranty 30W High power deliver procedures for class ID 4 Pin assignment V RJ 45 Pin 4 5 V RJ 45 Pin 7 8 TX RJ 45 Pin 1 2 RX RJ 45 Pin 3 6 Protection Provides Over current protection by PD class 10Base T 4 Pair UTP STP Cat 3 5e 6 cable EIA TIA 568 B 2 100 ohm up to100m 100Base TX 4 Pair UTP STP Cat 5e 6 cable EIA TIA 568 B 2 100 ohm up to 100m Power LED Power 1 Power 2 Green Fast Ethernet Port 1 4 Link Green Activity Green blinking PoE Powering Yellow on PoE Detect Yellow blinking PoE Disable Yellow off PoE Powering fail Yellow fast blinking Fast Ethernet Port 5 6 Link Green
43. raight through or crossover cables JetNet 3706f has 2 100Mbps fiber ports for multi mode or single mode fiber Note that crossover cables simply cross connect the transmit lines at each end to the received lines at the opposite end Switch Router or PC Switch Switch 3 TD 3 RD 3 TD 3 ID 6 TD 6 RD 6 TD 6 TD RD RD RD 1 TD 2 RD 2 RD 2 RD 2 TD Straight through Cabling Schematic Crossover Cabling Schematic Note Ethernet cables use pins 1 2 3 and 6 of an 8 pin RJ 45 connector The signals of these pins are converted by the automatic MDI X function as shown in the table below Pin MDI X MDI Signals Connect one end of an Ethernet cable into any switch port and connect the other end to your attached device The LINK LED will light up when the cable is connected correctly Refer to the LED Indicators section for descriptions of each LED indicator Always make sure that the cables connecting the switch and all attached devices e g switch hub or workstation are less than 100 meters 328 feet korenix The wiring cable types are as follows 10Base T 4 Pair UTP STP Cat 3 5e 6 cable EIA TIA 568 B 2 100 ohm up to100m 100Base TX 4 Pair UTP STP Cat 5e 6 cable EIA TIA 568 B 2 100 ohm up to 100m 2 5 Wiring Fast Ethernet Fiber Ports JetNet 3706f includes 2 fiber ports for Fast Ethernet Fiber uplink to other devices that are compatible with Fast
44. re Users can also browse the target folder and select the existing firmware file to upgrade the switch TFTP Server mode In this mode the switch acts as the TFTP client Before you do so make sure that your TFTP server is ready Then type in the TFTP Server IP address TFTP Server IP Address Key in the IP address of your TFTP Server here 18 korenix Firmware File Name View the file name of the new firmware The UI also shows you the version and built date of current firmware Please check the version number after you reboot the switch The following Web UI is for Firmware Upgrade Local File mode Firmware Upgrade System Firmware Version v1 0 System Firmware Date 20071002 15 38 14 Firmware Upgrade LocalFile w Firmware File Name FTPwetNet3706 v1 0 bin Mote When firmware upgrade is finished the ewitch will restart automatically Upgrade Click on the Folder icon to select the target file you want to backup restore The following Web UI is for Firmware Upgrade TFTP Server mode Firmware Upgrade System Firmware Version v1 0 System Firmware Date 20071002 15 39 14 Firmware Upgrade TFTP Server TFTP SewerIP 192 168 10 200 e File Name JetNet3706 v1 0 bin Mote When firmware upgrade is finished the switch will restart automatically Upgrade Type in the IP address of the TFTP Server and the Firmware File Name Then click Upgrade to start the process After finishing
45. t Port interface number Type 100BASE gt Fast Ethernet port Link Link status Up gt Link UP Down gt Link Down State Enable gt State is enabled Disable gt The port is disable by user configured Speed Duplex Current working status of the port Flow Control The state of the flow control Power over Ethernet Power over Ethernet is one of the key features of JetNet 3706 JetNet 3706f It is in compliance with IEEE 802 3af standards and supports 30w High power forwarding capability JetNet 3706 JetNet 3706f adopts 4 Port PoE injectors in port 1 to port 4 each port with the ability to deliver a 0 615mA current The following commands are included in this section 4 3 1 PoE Control 4 3 2 PoE Scheduling 4 3 3 PoE Status PoE Control Pull down the Powering Mode column can change the Powering Mode to IEEE 802 3af or forced mode When the column is IEEE 802 3af if and only if the PD is follow IEEE 802 3af then JetNet3706 JetNet 3706f could deliver power But if the Powering Mode changes to forced mode once the PoE mode is enabled the port will directly deliver power even there is no Ethernet cable plugged Please be careful when using forced mode suse Powering Mode BO Sat Force 23 korenix You can pull down the PoE state column to enable disable ports or set it to schedule control mode The Power Mode provides Standard mode for IEEE 802 3af PD Manual mode for user configuration of the po
46. t Port priority will follow DSCP Queue Mapping first and then CoS Queue Mapping rule Port Based The port priority will follow the queue priority that you have assigned The default priority type is CoS Only The system will provide a default CoS Queue table that you can refer to for the next command After configuring press Apply to enable the settings 4 5 2 CoS Queue Mapping This area is where the user can set CoS values to the Physical Queue mapping table Since the switch fabric of JetNet 3706 JetNet3706f supports 4 physical queues Lowest Low Middle and High users should assign CoS value to the level of the physical queue With the JetNet 3706 JetNet 3706f users can easily assign the mapping table or follow suggestions from the 802 1p standard Korenix uses 802 1p standards for its default values You will find that the CoS values 1 and 2 are mapped to physical Queue 0 lowest queue CoS values 0 and 3 are mapped to physical Queue 1 low normal physical queue CoS values 4 and 5 are mapped to physical Queue 2 middle physical queue and CoS values 6 and 7 are mapped to physical Queue 3 highest physical queue CoS Queue Mapping CoS Queue Mapping 0 Mote Queue 3 is the highest priol 2 Apply 3 After configuring press Apply to enable the settings 33 korenix 4 5 3 DSCP Queue Mapping 4 6 4 6 1 This is where users can change DSCP values to a Physical Queue mapping table Since the swit
47. tNet 3706 JetNet 3706f will calculate its power consumption using output current and voltage and will execute power budget limit protection Forced Powering Ability When set PoE operation mode to forced mode JetNet 3706 JetNet 3706f will directly deliver power even there is no Ethnernet cable plugged With this ability the powered device which doesn t follow IEEE802 3af could also be drivered power Quality of Service with WRR In order to obtain superior transmission performance JetNet3706 JetNet3706f enables QoS function with 8 4 2 1 WRR forwarding mechanism This feature ensures that real time services can be processed with high priority and without forwarding delays 1 2 Major Features Korenix JetNet 3706 and JetNet 3706f have the following features Four 10 100TX with PoE injector function Two 10 100TX ports with Auto MDI MDI X function JetNet 3706 Two 100Mbps fiber ports JetNet 3706f In compliance with IEEE802 3af and IEEE802 3at pre standards Supports Web browser and JetView management interface Patented Multiple Ring MSR Recovery time lt 5ms IEEE 802 1d 2004 edittion Rapid Spanning Tree PoE power limiting and scheduling control Active Link Partner Live Detect LPLD function IEEE 802 1p Class of Service and DSCP DiffServ QoS QoS supports Tage based port and IPv4 ToS End Point PoE architecture powered through conductors 4 5 7 8 Auto Detect Power Source Voltage DC 24v or 48V Over current Cable short protec
48. tch is a text file You can open it with Microsoft Word or any program that can read txt files modify the file add remove configuration settings and then restore it back on to the switch Startup Configuration File After you have saved the running config to flash the new settings will be updated after a power cycle You can use show startup config to view it in the CLI The Backup command can only backup such configuration files to your PC or TFTP server Technical Tip Default Configuration File The switch provides the default configuration file in the system You can use the Reset button Reload command to reset the system Running Configuration File The switch s CLI allows you to view the latest settings running on the system The information shown here are the settings you set up but have not saved to flash The settings not yet saved to flash will not work after a power the cycle You can use show running config to view it in the CLI The following figure is the Main UI for Backup amp Restore Backup amp Restore Backup Configuration LocalFile Backup File Name DirFTPibackun cont C4 Restore Configuration TFTP server w E 92 168 10 100 B backup conf The following figure is the WEB UI for Backup Restore Configuration Local File mode Backup Configuration LocalFile Y D ATFTFABackup canf Backup File Name 17 korenix 4 1 6 Click on the Folder icon to select the
49. the remote system crashes or is unstable JetNet 3706 JetNet 3706f will perform a system reboot by turning off and on again to trigger the remote device The following figure shows the Web configure interface for Power over Ethernet PD Status Detection PD Status Detection enable IP Address Cycle Timers 192 169 10 100 Mo You can enable disable PD Status Detection function and type in the IP address that you want to detect The Cycle Time is the gap per detection After configuring please click Apply to enable and perform the functions 4 3 2 PoE Scheduling The PoE Scheduling control is a powerful function to help you save power and money You need to configure PoE Scheduling and select a target port manually to enable this Power over Ethernet Schedule PoE Schedule on is Enabled function 25 korenix 4 3 3 PoE Status The PoE Status page shows the operating status of each PoE Port The information includes Detection status current PD class Power Consumption and delivered Voltage and Current Power over Ethernet Status 0 0 0 0 0 0 Disable Disabled PIA 2 Enable Delivering Power Class3 0 7 45 5 18 1 3 Enable Searching N A 0 0 0 0 0 0 4 Schedule Disabled N A 0 0 0 0 0 0 26 korenix 4 4 4 4 1 Network Redundancy It is critical for industrial applications for networks to continue working non stop JetNet 3706 JetNet 3706f supports standard RSTP Multiple
50. tion IP31 Aluminum housing for heightened heat radiation Redundant Power input DC 24 48V by Terminal Block 10 60 C 14 140 F operating temperature 1 2KV Hi pot testing passed IEEE standard compliance Note Detailed specifications are listed in Appendix 6 1 1 3 Package List Korenix JetNet 3706 JetNet 3706f ships with the following items B One Industrial PoE switch JetNet 3706 or JetNet3706f B One DIN Rail clip B One wall mount plate and screws korenix CD user manual B Quick Installation Guide If any of the above items are missing or damaged please contact your local sales representative 2 Hardware Installation The following topics are covered in this chapter 2 1 Hardware Introduction Dimensions Panel Layout Bottom View 2 2 Wiring Power Inputs 2 3 Wiring Earth Ground 2 4 Wiring Fast Ethernet Ports 2 5 Wiring Fast Ethernet Fiber Ports 2 6 Connecting Powered Device PD 2 Powering the Powered Device PD 2 8 DIN Rail Mounting Installation 2 9 Wall Mount Installation 2 1 Hardware Introduction Dimensions The dimensions of JetNet 3706 3706f are 174 8mmW x 46 5mmH x 136mmbD 6 82in W x 1 81in H x 5 30in D 0 a ILI L1 L3 L LI LI korenix Mylar Layout There is one Mylar that is on the top panel of the JetNet PoE Switch It includes 4 LEDs for system alarm system power status and RingMaster There are 10 LEDs for port operating status For detailed information please check the fol
51. tral Africa GMT 02 00 Athens Istanbul Minsk GMT 02 00 Bucharest GMT 02 00 Cairo GMT 02 00 Harare Pretoria GMT 02 00 Helsinki Riga Tallinn GMT 02 00 Jerusalem GMT 03 00 Baghdad GMT 03 00 Kuwait Riyadh GMT 03 00 Moscow St Petersburg Volgograd GMT 03 00 Nairobi GMT 03 30 Tehran GMT 04 00 Abu Dhabi Muscat GMT 04 00 Baku Tbilisi Yerevan GMT 04 30 Kabul GMT 05 00 Ekaterinburg GMT 05 00 Islamabad Karachi Tashkent GMT 05 30 Calcutta Chennai Mumbai New Delhi GMT 05 45 Kathmandu GMT 06 00 Almaty Novosibirsk 15 korenix GMT 13 00 Nuku alofa 51 GMT 06 00 Astana Dhaka 52 GMT 06 00 Sri Jayawardenepura 53 GMT 06 30 Rangoon 54 GMT 07 00 Bangkok Hanoi Jakarta 55 GMT 07 00 Krasnoyarsk 56 GMT 08 00 Beijing Chongqing Hong Kong Urumai 57 GMT 08 00 Irkutsk Ulaan Bataar 58 GMT 08 00 Kuala Lumpur Singapore 59 GMT 08 00 Perth 60 GMT 08 00 Taipei 61 GMT 09 00 Osaka Sapporo Tokyo 62 GMT 09 00 Seoul 63 GMT 09 00 Yakutsk 64 GMT 09 30 Adelaide 65 GMT 09 30 Darwin 66 GMT 10 00 Brisbane 67 GMT 10 00 Canberra Melbourne Sydney 68 GMT 10 00 Guam Port Moresby 69 GMT 10 00 Hobart 70 GMT 10 00 Vladivostok 71 GMT 11 00 Magadan Solomon Is New Caledonia 72 GMT 12 00 Aukland Wellington 73 GMT 12 00 Fiji Kamchatka Marshall Is Daylight Saving Time To set when Daylight Saving Time start and end During the Daylight Saving Time the device s time is
52. wer limit to IEEE 802 3af standard PD or Ultra mode for user configuration to perform at the 30w power limitation The following figure shows the Web UI interface for Power over Ethernet Control Power over Ethernet Control A fu ade WWE Th ort ower Mode Power Limitini 4 Ense vw Sandrd wif a sme stancara 3 73 Emme anual 549 4 enable vj urs v mo am You can type a value into the Power Limit column to set the limitation of power consumption If JetNet 3706 JetNet 3706f is set to Standard mode it will execute IEEE 802 3af power limiting rule by PD class The maximum value of Manual mode is 15 4w Ultra mode is 20w for each PoE port Note 1 Please pay attention when Powering Mode changed to forced moed Because directly delivering power may damage the non PoE device Note 2 For high power feeding JetNet 3706 JetNet 3706f must power with DC 55V to deliver maximum power Note 3 Ensure JetNet 3706 JetNet 3706f mounted on well heat radiated panel and under 60 environment during PoE port progress High Power forwarding High Power PoE Feeding will cause system temperature rised up DO NOT TOUCH DEVICE SURFACE DURING PoE PROGRESS HIGH POWER FEEDING 24 korenix PD Status Detection JetNet 3706 JetNet 3706f delivers a useful function PD Status Detection This provides automatic detection of a remote device powered by JetNet 3706 JetNet 3706f If