Home
testo 511 absolute pressure meter user manual
Contents
1. Bedienungsanleitung Mode d emploi Manual de instrucciones Manuale di istruzioni Manual de instruc es testo 511 de fr es It pt Short manual testo 511 11 Short manual testo 511 Protection cap Park position 2 Absolute pressure sensor nipple connection 3 Display 4 Control keys 5 Battery compartment holding magnets on rear Basic settings Instrument off gt press and hold O 2s gt select with A confirm with E Unit of height above mean sea level m ft gt Value of height above mean sea level Altitude gt Unit of pressure hPa mbar Pa mmH20 mmHg psi inH20 inHG gt Auto off function OFF ON Switching the instrument on Press Switching the display light on for 10s Instrument on gt press Select display size Instrument on gt select with Absolute pressure barom barometric pressure Altitude height above mean sea level Select display mode Instrument on gt select with oe Current reading gt Max Maximum values gt Min Minimum values Switching the instrument off Instrument on gt press and hold 2s 12 Safety and the enviroment Safety and the environment About this document gt Please read this documentation through carefully and familiarise yourself with the product before putting it to use Keep this document to hand so that you can refer to it when necessary Hand this documentation on to any subsequen
2. Measurement data Further instrument data Sensor Protection class IP40 Absolute pressure sensor Ambient conditions Parameters absolute barometric 0 50 C 32 122 F Pa hPa mbar mmH 0 mmHg inHG Storage transport conditions inH 0 psi 40 70 C 40 158 F Measuring ranges Voltage supply 300 1 200 hPa 120 4 481 8 inH 0 2x 1 5 V type AAA Resolutions Battery life 0 1 hPa 0 01 inH 0 200 h without display light Accuracies Dimensions Nominal temperature 22 C 1 Digit 119x46x25mm 4 7x1 8x1 0 in inc 3 hPa 1 2 inH 0 protection cap Measuring rate Weight 90g 3 2 oz inc batteries and 0 58 protection cap Directives standards and tests EC Directive 2004 108 EEC Warranty Duration 2 years Warranty conditions see guarantee card 14 Product description Product description At a glance Protection cap Park position 2 Absolute pressure sensor nipple connection 3 Display 4 Control keys 5 Battery compartment holding magnets on rear First steps gt Inserting batteries 1 To open the battery compartment push the battery cover down 2 Insert batteries 2x 1 5 V type AAA Observe the polarity 3 To close the battery compartment push the battery cover back on gt Basic settings configuration mode Adjustable functions Unit of height above mean sea level m ft Value of height above mean sea level Altitud
3. the current absolute pressure is also stored as a reference pressure When carrying out the measurement at the destination the weather conditions must be the same as when entering the reference altitude lf the weather has changed change of absolute pressure a new reference value must be entered gt Switching the instrument on gt Press Measuring mode is opened gt Switching the display light on Y The instrument is switched on gt Press The display light goes out automatically if no key is oressed for 10 seconds 16 Maintaining the product gt Changing the parameter H The parameter can be changed Adjustable parameters Absolute pressure barom barometric pressure Altitude height above mean sea level gt Press several times until the desired parameter appears gt Changing the display view Adjustable views Current reading Max Maximum values since the instrument was last switched on or last reset Min Minimum values since the instrument was last switched on or last reset gt Press several times until the desired view appears gt Resetting Max Min values 1 Press several times until the desired view appears 2 Press amp and hold until appears 3 Repeat steps 1 and 2 for all values that are to be reset gt Switching the instrument off gt Press and hold until the display goes out Maintaining the product gt Changing batteries 1 To op
4. e Set flashing figure with O change to next figure with Nes Unit of pressure hPa mbar Pa mmH20 mmHg psi inH20 inHG Auto off function OFF ON instrument switches off automatically if no key is pressed for 10 minutes 1 When switching the instrument on press and hold until A and appear on the display configuration mode The adjustable function is displayed The current setting flashes 2 Press A several times until the desired setting flashes Use the product 15 3 Press fes lt to confirm the input 4 Repeat steps 2 and 3 for all functions The instrument changes to measuring mode HR Using the product H For measuring barometric surface pressure barom pressure at sea level the following must be observed the altitude of the measurement site above sea level must be known and be set in the instrument see chapter First steps section Basic settings configuration mode The barometric pressure displayed is only correct for the altitude set for a change of altitude the altitude above sea level must be reset For measuring barometric Altitude altitude relating to a fixed level the following must be observed The altitude above sea level at the starting point of the measurement Reference altitude must be known and be set in the instrument see chapter First steps section Basic settings configuration mode When entering the reference altitude
5. en the battery compartment push the battery cover down 2 Remove used batteries and insert new batteries 2x 1 5 V type AAA Observe the polarity 3 To close the battery compartment push the battery cover back on gt Cleaning the housing gt Clean the housing with a moist cloth soap suds if it is dirty Do not use aggressive cleaning agents or solvents Tips and assistance 17 Tips and assistance Questions and answers C Question Possible causes solutions Hi or Lo Readings outside the measuring range too high too low Keep to the permitted measuring range L Residual capacity lt 10 min Change batteries If we could not answer your question please contact your dealer or Testo Customer Service Contact details can be found on the guarantee card or on the Internet at www testo com Accessories and spare parts Accessories and spare parts can be found in the product catalogues and brochures or in the internet at www testo com 18 Notes testo AG Postfach 1140 79849 Lenzkirch Testo Stra e 1 79853 Lenzkirch Telefon 07653 681 O Fax 07653 681 100 E Mail info testo de Internet http www testo com 0973 5111 03 Sh dr 10 04 2008
6. t users of the product Pay particular attention to information emphasised by the following symbols E Important Avoid personal injury damage to equipment gt Only operate the measuring instrument properly for its intended purpose and within the parameters specified in the technical data Do not use force Never store the product together with solvents acids or other aggressive substances Only carry out the maintenance and repair work that is described in the documentation Follow the prescribed steps when doing so Use only OEM spare parts from Testo Strong magnets Damage to other instruments gt Keep a safe distance from products which could be damaged by magnetism e g monitors computers pacemakers credit cards Protecting the environment gt Take faulty rechargeable batteries as well as spent batteries to the collection points provided for them Send the product back to Testo at the end of its useful life We will ensure that it is disposed of in an environmentally friendly manner Specifications 13 Specifications Functions and use 5 _ The testo 511 is an absolute pressure measuring instrument It is normally used to measure absolute pressure e g for pressure compensation in velocity measurement in ducts laboratories and production processes Further measurement parameters are barometric surface pressure pressure at sea level and altitude above sea level Technical data
Download Pdf Manuals
Related Search
Related Contents
Notice - Jardiland Doorbell - Jacob Jensen Store IT 6108 Infrared Transmitter Xerox® Phaser® 6500 - Xerox Support and Drivers crea/bulletin/6Juillet 2008 GUÍA DE USUARIO PARA LevelOne 4-Bay SATA NAS w/ Gigabit LAN KTM 530 XCR-W USA Motorcycle User Manual CELLULA 50 - confort Copyright © All rights reserved.
Failed to retrieve file