1. CTC Union Technologies Co Ltd Far Eastern Vienna Technology Center Neihu Technology Park 8F No 60 Zhouzi St Neihu Taipei 114 Taiwan 886 2 26591021 886 2 26590237 sales ctcu com info ctcu com marketing ctcu com H www ctcu com mn ISO 9001 Quality System Certified 2011 CTC Union Technologies Co LTD All trademarks are the property of their respective owners Technical information in this document is subject to change without notice PRODUCT union Quick Start Guide User Guide 1 CH E1 T1 100M Ethernet Fiber Multiplexer FRM220 FOM0O1 and FRM220 FOM01 SFP Table of Contents Introduction amp Features 1 Specifications 2 Management Features 2 Panel Installation 3 LED Indicators 4 Console Management amp Settings 5 Main Menu 6 Fiber 7 E1 T1 8 LAN 9 Loop Back Diagnostics 10 E1 Signal Pin Assignment 10 Applications 11 Upgrading 12 About SFP Units 13 Version 1 1 Jun 08 2011 www CTCU com Introduction FRM220 FOM01 is a single channel E1 T1 fiber multiplexer with an additional wire speed 100M Ethernet trunk constructed as a one slot wide card for FRM220 series When FRM220 FOM01 card is placed in FRM220 rack with NMC the management can view the multiplexer card s status type version fiber link status and alarms The card can be configured to enable or disabl
2. lt 2 gt Negotiation This LAN port supports both auto negotiation per IEE802 3u and manual forced mode When in auto the speed and duplex settings are ignored lt 3 gt Speed When using manual forced mode the speed of the LAN can be configured to either 10M or 100M lt 4 gt Duplex When using manual forced mode the duplex of the LAN can be configured to either FULL or HALF duplex lt 5 gt LFP The link fault pass through function allows a link failure to propagate over the Ethernet trunk If enabled an Ethernet link loss on this FOM01 will force a link down on the remote FOM01 LAN port Link Fault Pass Through Function lt l gt Disable lt 2 gt Enable lt ESC gt Go to previous menu Please select an item www CTCU com Loop back Testing LBT The loop back capability of FRM220 FOMO01 is useful for debugging a dysfunctional link or when commissioning a link The optical channel and the TDM channel E1 T1 support local and remote loop back functions Loop back is enabled via management terminal console When placed in a managed FRM220 CH20 chassis the loop back can be controlled by NMC manager in FRM220 chassis Local Side Remote Side FX and E1 T1 LLB Local Loop Back Local Side Remote Side FX and E1 T1 RLB Remote Loop Back Figure 4 Fiber and E1 T1 Loop back modes for FRM220 FOM01 E1 Signal Pin Assignment 1 R RXRing Orange White White Green TX Ring Blue Wh
3. Tx Wave Length 1310 nm RX Wave Length 1310 nm Link Length 0040 Km Tx Power 11 dBm Rx Power 41 dBm Rx Sensitivity 52 dBm Temperature 39T lt ESC gt Go to previous menu Please select an item Note Tx Power Rx Power Rx Sensitivity and Temperature are only available in SFP modules that support optional DOM digital optical monitoring or DD function lt 1 gt Loop Back Test Mode Use this menu item to activate one of the loop back modes for the fiber link Refer to page 10 for available loop back modes Fiber Port Loop Back Test Function Select lt l gt Disable lt 2 gt LLB lt 3 gt RLB lt ESC gt Go to previous menu Please select an item www CTCU com E1 T1 From the main menu select item number 3 to access the E1 T1 status menu Local Version 1 000 1 000 0 000 1 200 FOMO01 SFP CHO1M lt lt E1 T1 Status and Configuration gt gt lt 1 gt Termination Type E1 75 BNC Link Up lt 2 gt E1 T1 Service On BVP Error Normal lt 3 gt Line Code HDB3 J lt 4 gt Loop Back Test Mode Disable lt ESC gt Go to previous menu Please select an item lt 1 gt Termination Type Use this item to set the transmission mode The modes available are E1 75 E1 120 or T1 100 lt 2 gt E1 T1 Service Enable or disable the transmission on this channel lt 3 gt Line Code Set the appropriate line coding for the application lt 4 gt Lo
4. 0 1 000 0 000 1 200 FOMO1 SFP CH0O1M lt l gt Device Service On lt 2 gt Fiber Status and Configuration lt 3 gt E1 T1 Status and Configuration lt 4 gt LAN Status and Configuration lt 5 gt Store Configuration lt 6 gt Default Configuration lt P gt Setting Password lt T gt Switch To Remote Menu Absent Please select an item Example of Main Menu Console Screen FRM220 FOM01 Notice All of these settings are ignored if the card is placed in FRM220 CH20 with NUC SNMP management The card will follow the settings done via the chassis management Refer to NMC operation manual for details on managing all cards 5 www CTCU com Main Menu Description lt 1 gt Device Status under this menu will be the device service status lt 2 gt Fiber this menu provides access to the fiber optical related functions including link status port activation loop back tests and viewing of SFP DD functions lt 3 gt E1 T1 Sets the E1 T1 mode and then provides status and configuration for the E1 T1 channel including service activation line code setting and loop back functions lt 4 gt LAN The LAN sub menu provides status and port setting for auto forced flow control and Link Fault Pass thru LFP lt 5 gt Store This key in provides saving all settings lt 6 gt Default The key in will return the device to factory default settings lt P gt Setting Password Protect against un
5. RM220 FOM04 TEC FRM220 3R 10G SXX FRM220 FOM01 Previous Menu RM220 E1 DATA RM220 FOM04 FPGA R 4G 2S 3S FRM220 3R 10G SXX CDR FRM220 FOM01 FPGA mj j j m N AY Ay Select the line card type FOM01 or FOM01 FPGA the slot number and local unit Enter filename and lastly enter 1 to start the upgrade or any other key to abort The upgrade should complete in only a couple of minutes DO NOT disconnect or pullout insert any other cards during the upgrade process 12 www CTCU com About SFP Units FRM220 FOM01 SFP accepts any SFP unit that complies with the MSA standard and supports an OC3 STM 1 data rate which in FOMO1 is 155 52Mbps Do NOT try to use copper interface type SFP modules The optical transmission of FOMO01 is a proprietary scrambled NRZ coding Follow all ESD precautions when handling the card and pluggable modules Fiber optic components and cables are very sensitive to dirt dust and mishandling especially in high speed networks Dirty or mistreated fiber may cause errors and an unwanted degradation of signal quality Remove the dust caps on SFP only when ready to plug in optical cables Installation CTC Union supplied SFP modules are of the Bale Clasp type The bale clasp pluggable module has a bale clasp that secures the module into the SFP cage e Inserting a Bale Clasp SFP Module into the cage Step 1 Close the bale clasp upward before inserting the pluggable module Ste
6. When placed in NMC managed rack all other settings are overridden by NMC management 2 www CTCU com Panel There are 2 x RJ 45 connectors one for E1 T1 channel USOC RJ48C connection to balanced E1 or T1 and one for Ethernet Do not mix them up The optical aggregate utilizes SFP cage or fixed transceiver SFP used must support 155M OC3 STM1 data rates and be MSA compliant The single LAN connector RJ 45 supports 10 100Base Ethernet connection with auto negotiation and auto MDIX 7 x E z za ANITX djs lLoWOo4d Figure 1 Front Panel of FRM220 FOM01 and FOM01 SFP Installation Note Unless FOM071 is placed in 20 slot or 2 slot chassis with NMC this multiplexer card can only be placed in the CHO1M or CH02M as stand alone CH01M AD Chassis Internal AC DC w console port FRM220 CH20 aka FMUX20 Figure 2 Slide in Card mounting of FRM220 FOM01 Follow all ESD precautions when handling the card and SFP modules Boa www CTCU com LED Indicators YNITX4 n O X ted oO Z Te A o 7 v Figure 3 Panel LED indicators of FRM220 FOM01 LED State Status On Unit is powered normally P EEN Off Unit is powered off or bad On Optical Fiber Linked cA Kareen Off Optical Fiber no link On E1 Mode 75 Ohm E1 Green Flash E1 Mode 120 Ohm Off T1 Mode 100 Ohm E1 T1 Green On E1 T1 Signal Present LINK Off E1 T1 LOS E1 T1 Amber On E1 T1 Loop Back Test active TEST Off Norm
7. al LAN On Ethernet UTP has link LINK Green Flash Ethernet UTP has link and traffic Off No UTP link LAN Green On Speed is 100M 100 Off Speed is 10M 4 www CTCU com Console Management When placed in the 1 slot CHO1M chassis this card can be locally managed by connecting a simple serial terminal such as a notebook computer that has an RS232 port or via a commonly available USB to RS232 adapter In Windows XP HyperTerminal is an application available for emulating a serial terminal You can also search for TeraTerm or PuTTY which are free alternatives especially if the operating system is Vista or Win7 FOM01 with CHO1M uses the DB9 serial connector labeled CONSOLE and a DB9M to DB9F one to one cable to connect to the PC COM port Connect the DB9F labeled CONSOLE to the COM port of the management PC When placed in CH02M chassis connect console to CH02M s DB9F and slide the switch to the right slot number Settings Baud Rate 38 400 Data bits 8 Parity bits none Stop bits 1 Flow Control none Emulation VT 100 Connect the serial cable directly to CHO1M s DB9F Run the terminal emulation program With power on press ESC or Enter to display the Main Menu screen The following is an example KKK KK KKK KKK KK KKK KKK KKK KKK KKK KKK KKK KK KKK CTC UNION TECHNOLOGIES CO LTD FRM220 FOM01 Manager Ver 1 00 AS KKK KKK KK KEK KKK KKK KKK KKK KKK KK KKK KKKKK KKK KK Local Version 1 00
8. authorized access lt T gt Remote when a fiber link exists between the local and remote FOMO01 in band is active using this will toggle between local and remote management Device Status KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KK KK x CTC UNION TECHNOLOGIES CO LTD x FRM220 FOM01 Manager Ver 1 00 RRR KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KK KK Local Version 1 000 1 000 0 000 1 200 FOMO1 SFP CHO1M Device Service Select lt l gt Service On lt 2 gt Service Off lt ESC gt Go to previous menu Please select an item lt 1 gt Service On Use this item to place the entire FOM01 IS in service or On lt 2 gt Service Off Use this item to place the entire FOM01 OOS out of service or Off lt ESC gt Escape Go back to the main menu www CTCU com Fiber From the main menu select item number 2 to access the fiber status menu KKK KKK KKK KKK KKK KKK KK KKK KKK KKK KKK KKK KK KKK CTC UNION TECHNOLOGIES CO LTD FRM220 FOMO1 Manager Ver 1 00 KK KKK KKK RK KKK KKK KKK KKK KKK KKK KKK KKK KKK KK KKK Local Version 1 000 1 000 0 000 1 200 FOMO1 SFP CHO1M lt lt Fiber Status and Configuration gt gt OP Link Up Remote PWR OK OP Small Form Pluggable Yes Digital Diagnostic Function Yes lt 1 gt Loop Back Test Mode Disable Vendor Name FIBERXON INC Vendor Part Number FTM 3125C L40 Fiber Type Single
9. e required FRM220 FOMO01 is a cost effective alternative to expensive SDH or SONET equipment 11 www CTCU com Upgrading FRM220 FOM01 card may be firmware upgraded when it is placed in FRM220 with NMC management card The user may use a local console connection to the NMC a remote Telnet IP connection or a Web based HTTP connection with any available browser The NMC communicates to all cards through a serial RS485 control bus The upgrade code is transferred to the NMC by way of TFTP server and then on to the line card s Quick Procedure Place the line card s upgrade code on the TFTP server either f w or FPGA code or both Make sure you know the case sensitive file name Connect to FRM220 NMC by local console or by remote Telnet connection From the main menu choose lt L gt SNMP System Configuration Setup Then lt U gt Upgrade Line Card Menu lt lt Upgrade Line Card Menu gt gt Target IP t So 125 162 252 Target Gateway 559 125 162 241 TFTP Server IP 125 162 243 Please select a card type lt 1 gt FRM220 10 100I and FMC 10 1001 LLAD RM220 FXO FXS lt 5 gt E RM220 DATAPORT lt 7 gt FRM220 1000EDS 1000ES 2F 1 25 RM220 SERIAL RM220 155MS RM220 E1 T1 RM220 1000ES 1 1000E yA ey Ay my A ayy RM220 10 1001S 2 RM220 3R 2 7G 2S 3S RM220 5E1 ET100S RM220 3R 10G SS SX XX RM220 1000TS 1000T RM220 5E1 ET100T RM220 Eoel RM220 3R 10G SS SX XX my RY RY Ay my Ry yy RM220 MUX DEMUX
10. e the port reset the port and provide local or remote diagnostic loopback The optical aggregate of this multiplexer employs either fixed transceiver or industry standard pluggable optics SFP that operate at OC3 STM 1 data rates 155M depending on model The aggregate can be chosen to support any of the following e Single mode e Multi mode e Single fiber bi directional e Coarse and Dense Wave Division Multiplexing CWDM and DWDM Features e 1 channel unframed E1 T1 plus wire speed 10 100Base TX Ethernet e Auto MDI MDIX Auto Negotiation or Force mode e Supports flow control e Supports 9k Jumbo packets e Supports Link Fault Pass through LFP e Supports Digital Diagnostics Monitoring Interface DDMI with SFP model e Loopback tests for E1 T1 and fiber port e Supports Dying Gasp senses remote power failure e Supports local and remote In band management e Stand alone monitor and configuration by menu driven serial console port e Supports On Line F W upgrade via FRM220 NMC management WARNING Fiber optic equipment may emit laser or infrared light that can injure your eyes Never look into an optical fiber or connector port Always assume that fiber optic cables are connected to a laser light source 1 www CTCU com Specifications E1 T1 Interface Framing Unframed transparent Bit Rate E1 2 048 Mb s T1 1 544Mb s Line Code E1 AMI HDB3 T1 AMI B8ZS E1 Unbalanced 75 ohms BNC cable E1 Bala
11. ite TX Tip White Blue reserved Green White shield White Brown shield Brown White The 8P8C connector wiring for balanced E1 follows the Universal Service Order Code USOC RJ48C registered jack standardization 10 www CTCU com Applications FRM220 FOM01 1 T1 fiber multiplexer works in point to point applications either as a stand alone or when placed in FRM220 CH20 managed rack Mobile back haul with Voice amp Data FOMO1 FOMO1 1 CH 1 CH E111 BSC BTS 4 1 plus plus 100M 100M Ethernet co CPE Ethernet Figure 5 Typical application for FRM220 FOMO01 Set local and remote multiplexers to the right E1 T1 transport and enable the port Configure the LAN port for proper connection either with auto negotiation or by manual forced mode An in band management channel will transparently carry configuration data from remote side equipment back to the central side for remote management For normal operation ensure that all Loop Backs are disabled for optical and TDM Branch office connection If you have available dark fiber FRM220 FOM01 makes an excellent inter office connect The E1 channel can each carry 30 voice trunk lines between your main and branch offices PBX equipment The full wire soeed Ethernet trunk can provide an excellent LAN to LAN connection at 100M speed SDH alternative In a point to point application where only a single E1 or T1 plus full 100M Ethernet over a single fiber pair ar
12. nced 120 ohms RJ48C T1 Balanced 100 ohms RJ48C Rx sensitivity Short haul Pulse Amplitude Nominal 2 37V 10 for 75 ohms Nominal 3 00V 10 for 120 ohms Zero Amplitude Nominal 0 3V Internal Timing 50 ppm Jitter Performance According to ITU T G 823 Performance Monitor According to ITU T G 821 Line Impedance Standards ITU T G 703 G 704 G 706 and G 732 RJ 45 BNC via RJ 45 to BNC adapter cables LLB Local Loop Back RLB Remote Loop Back I F Connector Test Loops Ethernet Interface Interface Type 10 100Base TX Connector RJ 45 Standards IEEE 802 3 802 3u Duplex modes Full Half Test Loops None Miscellaneous Indicators Fx Link E1 T1 Mode Link Loopback test LAN Link Speed Humidity 10 90 RH non condensing CE EMC amp LVD FCC RoHS Power Input AC adapter 12VDC Dimensions 88 x 21 x 1389mm HxWxD Temperature 0 60 Operating 10 70 Storage Certifications Management Features FRM220 FOMO01 has no jumpers or DIP switches making it completely software configurable When placed in a stand alone chassis this device supports a text based serial terminal with an easy to use menu system for configuration When placed in a managed chassis FOMO01 is configured and monitored through chassis NMC network management controller via console Telnet Web HTTP or SNMP 1 Stand alone with serial console and menu driven settings 2 Rack management
13. op Back Test Mode Refer to page 10 for available loop back modes Local Version 1 000 1 000 0 000 1 200 FOMO1 SFP CHO1M lt lt E1 T1 Status and Configuration gt gt lt 1 gt Termination Type E1 75 BNC Link Up lt 2 gt E1 T1 Service On BVP Error Normal lt 3 gt Line Code HDB3 lt 4 gt Loop Back Test Mode Disable lt ESC gt Go to previous menu Please select an item El T1 Loop Back Test Function Select lt 1 gt Disable lt 2 gt LLB lt 3 gt RLB lt ESC gt Go to previous menu Please select an item Note Both E1 and T1 support AMI Alternate Mark Inversion line coding However in most cases E1 will use HDB3 and T1 will use B8ZS line coding 8 www CTCU com LAN From the main menu select item number 4 to access the LAN status menu KKK KKK KKK KKK KKK KKK KK KKK KKK KKK KKK KKK KK KKK CTC UNION TECHNOLOGIES CO LTD FRM220 FOMO1 Manager Ver 1 00 pia KK KKK KR KKK KKK KKK KKK KKK KKK KK KK KK KK KK KK KKK Local Version 1 000 1 000 0 000 1 200 FOMO1 SFP CH0O1M lt lt LAN Status and Configuration gt gt lt 1 gt LAN Service On Link Up lt 2 gt Negotiation Auto lt 3 gt Speed 100 Status 100 lt 4 gt Duplex Full Status Full lt 5 gt Link Fault Pass Through Function Disable lt ESC gt Go to previous menu Please select an item lt 1 gt LAN Service Enable or disable the transmission on the LAN trunk
14. p 2 Line up the SFP module with the port and slide it into the cage e Removing a Bale Clasp SFP Module Step 1 Open the bale clasp on the SFP module Press the clasp downward with your index finger Step 2 Grasp the SFP module between your thumb and index finger and carefully remove it from the SFP cage Figure 6 Bale Clasp SFP with bale open 13 www CTCU com