DR130/DR231/DR241 Hybrid Recorder(Stand-alone
Contents
1. Electric Corporation for IM DR231 01E Sth Edition E Page 2 15 HOLD NON HOLD Setting You can select whether to hold the operating status of operated internal switches or alarm output relays This setting applies to both the internal switches and the alarm output relays However non hold always applies to relays for which the reflash alarm is set regardless of the hold non hold setting E Page 3 16 WARNING e When 30 VAC or 60 VDC and more is applied to the output terminal of the alarm output module or the output terminal of the DI DO module use double insulated wires withstand voltage performance more than 2300 VAC for those wires which apply 30 VAC or 60 VDC and more All other wires can be basic insulated withstand voltage performance more than 1390 VAC Furthermore use crimp on lugs for 4 mm screws with insulation sleeves for connecting to the screw terminal Make sure that the crimp on tool must be one specified by the crimp on lugs manufacture and that the crimp on lugs and tool must be matched to the wire size To prevent from electric shock do not touch the terminal after wiring and make sure to re apply the cover e To prevent fire use signal wires having a temperature rating of 75 C or more HE Page 3 16 CAUTION The overvoltage category of each input module is CAT Il CSA1010 1 The measurement category of each input module is CAT II IEC61010 1 e When connecting to a clamp te
2. appears on the display see Section 13 4 Error Codes If servicing is necessary or if the instrument is not operating correctrly though the following corrective actions have been taken please contact your nearest YOKOGAWA representative dealer or sales office IM DR231 01E 98 2 3 for IM DR231 01E 9th Edition E Page 13 5 Added to the 13 4 Error Codes The following error codes have been added to the list Error Codes Error Corrective Action 013 Attempted REP RECALL START without hourly daily or monthly report data 032 Set to contiguous channels on the power monitor Enter a correct channel module 047 Entered a wiring method for which there is no Enter the correct wiring method setting for the power monitor module 107 Attempted to change ranges or time while report Do not make changes was Starting 131 Media write error Exchange the medium 137 Attempted to start computation or execute a Start the procedure or computation after completion of procedure during saving of settings toa medium the media operation or while reading from a medium 138 Media drive error Exchange the medium If the error occurs again after exchanging the medium servicing is required 170 The IP address does not belong to any of the Set the correct IP address classes A B or C 171 There is a hole in the mask or the host address Set the correct subnet mask section is not released 172 The net
3. User s DR130 DR231 DR241 Notice of Alterations Manual Hybrid Recorder Stand alone model SSeS SSS SS EEE Please note the following underlined alterations to the IMDR231 01E E Page 3 Main Unit DR130 DR231 DR241 Model Suffix Code Description Power Cord Dessi 3 pin inlet w UL CSA cable Part No A1074WD Feree 3 pin inlet w VDE cable Part No A1009WD Reve 3 pin inlet w AS cable Part No A1024WD Sree 3 pin inlet w BS cable Part No A1023WD Hee 3 pin inlet w GB cable complies with the CCC Part No A1064WD Weres 3 pin inlet with screw conversion terminal Yous 3 pin inlet with screw conversion terminal HE Page 5 Standard Accessories 1 One of these power cord types is supplied according to the instrument s suffix code MPage7 Safety Precautions The following caution has been added CAUTION This instrument is a Class A product Operation of this instrument in a residential area may cause radio interference in which case the user is required to take appropriate measures to correct the interference E Chapter 3 Note the following additions to Slot Numbers and Channel Numbers Slot number Unit number 0 Fixed 041 to 050 021 to 030 001 to 010 lt ___ Channel number 051 to 060 031 to 040 011 to 020 IN7 051 to 052 N8 051 to 056 YOKOGAWA IM DR231 01E 98 1 3 Yokogawa
4. address section including the subnet does Set the correct net address not match the subnet section of the IP address 173 The host address section of the IP address is Set the correct IP address either all zeroes or all ones E Page 14 9 Standard Computation Functions Scaling Measurement accuracy for scaling measurement accuracy for scaling digits measurement accuracy digits x scaling span digits measurement span digits 2 digits Numbers below the decimal point are rounded up 0 05 100 x 5000 2 x 2000 4000 2 4 25 Measurement accuracy 5 digits 0 005 V H Page 14 14 Normal Operation Conditions Installation category based on IEC61010 1 DSA22 2 No 61010 1 Wt Pollution degree based on 22 Warm up time At least 30 minutes after power switch on IEC61010 1 DSA22 2 No 61010 1 1 Describes a number which defines a transient overvoltage condition It implies the regulation for impulse withstand voltage ll applies to electrical equipment which is supplied from fixed installations like distribution boards 2 Describes the degree to which a solid liquid or gas which deteriorates dielectric strength or surface resistivity is adhering 2 applies to normal indoor atmosphere Normally only non conductive pollution occurs H Page 14 15 EMC Conformity Standards Please refer to these specifications instead of the one printed in the user s
5. manual Safety and EMC Standards CSA CSA22 2 No 61010 1 installation category Il pollution degree 2 UL UL61010 1 CSA NRTL C C Tick EN55011 compliance Class A Group 1 KC marking Electromagnetic wave interference prevention standard electromagnetic wave protection standard compliance IM DR231 01E 98 3 3 for IM DR231 01E 9th Edition
6. rminal use a signal conductor with the following cross sectional width e The power monitor module is a product belonging to Installation Over voltage Category CAT II CSA1010 1 _The power monitor module is a product belonging to Measurement Category CAT II IEC61010 1 HE Page 3 22 WARNING To prevent electric shock do not touch the terminals after wiring Furnish a switch double pole type to separate the instrument from the main power supply in the power supply line In addition make sure to indicate that the switch is a power control for the instrument on the switch and the ON OFF positions of the switch Switch Specifications Steady state current rating 3 A or more inrush current rating 90 A or more AC power suppl Steady state current rating 8 A or more inrush current rating 90 A or more DC power suppl Use a switch complied with IEC60947 1 3 e Do not add a switch or fuse to the ground line E Page 4 13 Clock Display The date and time can be displayed on sub display 2 According to the set time in 3 7 Setting the Date and Time see to page 3 25 the current date and time can be displayed E Page 10 6 Selection of Recording Interval in Digital Printing Logging Mode LOG INTERVAL e SINGLE e Digital print The interval is determined by the chart speed and the number of columns to be printed See the table in chapter 14 page 14 8 E Page 13 4 13 3 Troubleshooting If an error code